Abstract
The BACTEC 9240 (Becton Dickinson, Sparks, Md.) automated blood culture system is based on the continuous monitoring of CO2 production by means of a fluorescent sensor attached to the bottom of culture vials. We compared the performance of the BACTEC aerobic Plus/F medium to that of the Septi-Chek Release medium (Becton Dickinson, Sparks, Md.), a manual biphasic blood culture system. Sets consisting of BACTEC aerobic Plus/F and Septi-Chek Release vials inoculated with similar volumes (7 +/- 2 ml) were evaluated. In the laboratory, systems were equipped and analyzed according to the manufacturer's recommendations. The BACTEC and Septi-Chek vials were incubated at 35 degrees C for 5 days. A total of 6,116 compliant sets were obtained from 1,972 adult patients (3.1 cultures per patient). Of these, 731 (12%) were culture positive, including 612 (10%) that yielded at least one pathogen, and 143 (2%) were considered to be contaminated. Of the 672 pathogenic organisms detected, 524 were isolated from the BACTEC aerobic Plus/F medium and 574 were isolated from the Septi-Chek Release medium, 428 organisms grew in both media, 96 organisms grew only in the BACTEC aerobic Plus/F medium, and 146 organisms grew only in the Septi-Chek Release medium (P = 0.001). Haemophilus spp. were isolated more often (P = 0.03) from the BACTEC aerobic Plus/F medium; however, more Streptococcus anginosus organisms (P = 0.02), members of the Enterobacteriaceae family (P < 0.03), and gram-negative anaerobes (P = 0.03) were isolated from the Septi-Chek Release medium. Pathogenic organisms were detected significantly earlier (P < 0.0001) with the BACTEC aerobic Plus/F medium in conjunction with the BACTEC 9240 instrument than with the Septi-Chek Release medium.
Full Text
The Full Text of this article is available as a PDF (187.7 KB).
Selected References
These references are in PubMed. This may not be the complete list of references from this article.
- Koontz F. P., Flint K. K., Reynolds J. K., Allen S. D. Multicenter comparison of the high volume (10 ml) NR BACTEC PLUS system and the standard (5 ml) NR BACTEC system. Diagn Microbiol Infect Dis. 1991 Mar-Apr;14(2):111–118. doi: 10.1016/0732-8893(91)90044-g. [DOI] [PubMed] [Google Scholar]
- Masterson K. C., McGowan J. E., Jr Detection of positive blood cultures by the Bactec NR660. The clinical importance of five versus seven days of testing. Am J Clin Pathol. 1988 Jul;90(1):91–94. doi: 10.1093/ajcp/90.1.91. [DOI] [PubMed] [Google Scholar]
- Nolte F. S., Williams J. M., Jerris R. C., Morello J. A., Leitch C. D., Matushek S., Schwabe L. D., Dorigan F., Kocka F. E. Multicenter clinical evaluation of a continuous monitoring blood culture system using fluorescent-sensor technology (BACTEC 9240). J Clin Microbiol. 1993 Mar;31(3):552–557. doi: 10.1128/jcm.31.3.552-557.1993. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Rohner P., Burkardt H., Dreismann H., Auckenthaler R. Evaluation of the new improved BHI-lysis blood culture medium for the BCB Roche system. Eur J Clin Microbiol Infect Dis. 1991 Aug;10(8):620–624. doi: 10.1007/BF01975812. [DOI] [PubMed] [Google Scholar]
- Rohner P., Pepey B., Auckenthaler R. Comparison of BacT/Alert with Signal blood culture system. J Clin Microbiol. 1995 Feb;33(2):313–317. doi: 10.1128/jcm.33.2.313-317.1995. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Weinstein M. P., Mirrett S., Reimer L. G., Wilson M. L., Smith-Elekes S., Chuard C. R., Joho K. L., Reller L. B. Controlled evaluation of BacT/Alert standard aerobic and FAN aerobic blood culture bottles for detection of bacteremia and fungemia. J Clin Microbiol. 1995 Apr;33(4):978–981. doi: 10.1128/jcm.33.4.978-981.1995. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Weinstein M. P., Mirrett S., Wilson M. L., Harrell L. J., Stratton C. W., Reller L. B. Controlled evaluation of BACTEC Plus 26 and Roche Septi-Chek aerobic blood culture bottles. J Clin Microbiol. 1991 May;29(5):879–882. doi: 10.1128/jcm.29.5.879-882.1991. [DOI] [PMC free article] [PubMed] [Google Scholar]