Skip to main content
Journal of Clinical Microbiology logoLink to Journal of Clinical Microbiology
. 1996 May;34(5):1327–1329. doi: 10.1128/jcm.34.5.1327-1329.1996

Comparison of BacT/Alert FAN medium with BACTEC NR660 Plus 26A medium.

J W Snyder 1, S K Lude 1
PMCID: PMC229012  PMID: 8727933

Abstract

A total of 6,010 blood culture sets were obtained from adult patients with suspected bacteremia or fungemia. The overall recovery of organisms was equivalent in two systems used, BacT/Alert FAN medium and BACTEC NR660 Plus 26A medium.

Full Text

The Full Text of this article is available as a PDF (142.6 KB).

Selected References

These references are in PubMed. This may not be the complete list of references from this article.

  1. Garner J. S., Jarvis W. R., Emori T. G., Horan T. C., Hughes J. M. CDC definitions for nosocomial infections, 1988. Am J Infect Control. 1988 Jun;16(3):128–140. doi: 10.1016/0196-6553(88)90053-3. [DOI] [PubMed] [Google Scholar]
  2. Pohlman J. K., Kirkley B. A., Easley K. A., Basille B. A., Washington J. A. Controlled clinical evaluation of BACTEC Plus Aerobic/F and BacT/Alert Aerobic FAN bottles for detection of bloodstream infections. J Clin Microbiol. 1995 Nov;33(11):2856–2858. doi: 10.1128/jcm.33.11.2856-2858.1995. [DOI] [PMC free article] [PubMed] [Google Scholar]
  3. Tarrand J. J., Guillot C., Wenglar M., Jackson J., Lajeunesse J. D., Rolston K. V. Clinical comparison of the resin-containing BACTEC 26 Plus and the Isolator 10 blood culturing systems. J Clin Microbiol. 1991 Oct;29(10):2245–2249. doi: 10.1128/jcm.29.10.2245-2249.1991. [DOI] [PMC free article] [PubMed] [Google Scholar]
  4. Thorpe T. C., Wilson M. L., Turner J. E., DiGuiseppi J. L., Willert M., Mirrett S., Reller L. B. BacT/Alert: an automated colorimetric microbial detection system. J Clin Microbiol. 1990 Jul;28(7):1608–1612. doi: 10.1128/jcm.28.7.1608-1612.1990. [DOI] [PMC free article] [PubMed] [Google Scholar]
  5. Weinstein M. P., Mirrett S., Reimer L. G., Wilson M. L., Smith-Elekes S., Chuard C. R., Joho K. L., Reller L. B. Controlled evaluation of BacT/Alert standard aerobic and FAN aerobic blood culture bottles for detection of bacteremia and fungemia. J Clin Microbiol. 1995 Apr;33(4):978–981. doi: 10.1128/jcm.33.4.978-981.1995. [DOI] [PMC free article] [PubMed] [Google Scholar]
  6. Weinstein M. P., Mirrett S., Wilson M. L., Reimer L. G., Reller L. B. Controlled evaluation of 5 versus 10 milliliters of blood cultured in aerobic BacT/Alert blood culture bottles. J Clin Microbiol. 1994 Sep;32(9):2103–2106. doi: 10.1128/jcm.32.9.2103-2106.1994. [DOI] [PMC free article] [PubMed] [Google Scholar]
  7. Wilson M. L., Weinstein M. P., Reimer L. G., Mirrett S., Reller L. B. Controlled comparison of the BacT/Alert and BACTEC 660/730 nonradiometric blood culture systems. J Clin Microbiol. 1992 Feb;30(2):323–329. doi: 10.1128/jcm.30.2.323-329.1992. [DOI] [PMC free article] [PubMed] [Google Scholar]

Articles from Journal of Clinical Microbiology are provided here courtesy of American Society for Microbiology (ASM)

RESOURCES