Skip to main content
Applied and Environmental Microbiology logoLink to Applied and Environmental Microbiology
. 1982 Nov;44(5):1246–1247. doi: 10.1128/aem.44.5.1246-1247.1982

Comparison of the Pour, Spread, and Drop Plate Methods for Enumeration of Rhizobium spp. in Inoculants Made from Presterilized Peat

H J Hoben 1, P Somasegaran 1
PMCID: PMC242176  PMID: 16346141

Abstract

Inoculants prepared with presterilized peat were enumerated by the pour, spread, and drop plate techniques. Results indicated that the three plating methods were interchangeable. The drop plate method was preferred because of its economy in materials and labor.

Full text

PDF
1246

Images in this article

Selected References

These references are in PubMed. This may not be the complete list of references from this article.

  1. Clark D. S. Comparison of pour and surface plate methods for determination of bacterial counts. Can J Microbiol. 1967 Nov;13(11):1409–1412. doi: 10.1139/m67-187. [DOI] [PubMed] [Google Scholar]

Articles from Applied and Environmental Microbiology are provided here courtesy of American Society for Microbiology (ASM)

RESOURCES