Abstract
Verification of membrane filter total coliform colonies was compared in lauryl tryptose broth, and m-LAC broth primary media and brilliant green-lactose-bile broth and EC broth secondary media. Verification in m-LAC broth yielded the greatest number of aerogenic isolates for both untreated surface water and drinking water samples. Verification in brilliant green-lactose-bile broth increased the number of false-negative reactions. At least 90% of the isolates aerogenic in primary verification media and anaerogenic in brilliant green-lactose-bile broth were representative of the coliform genera. The addition of a resuscitation step in the membrane filter technique did not yield greater numbers of verified coliforms per sample. Verification of both typical and atypical colonies in m-LAC broth resulted in a 10-fold increase in coliform numbers from untreated surface water. With drinking water, verification of both colony types resulted in an increase from less than 1 coliform per 100 ml to greater than 1/100 ml. A single-step verification in m-LAC broth is proposed as a more rapid and sensitive coliform verification procedure than the standard technique.
Full text
PDFSelected References
These references are in PubMed. This may not be the complete list of references from this article.
- CHAMBERS C. W. Relationship of coliform bacteria to gas production in media containing lactose. Public Health Rep. 1950 May 12;65(19):619–627. [PMC free article] [PubMed] [Google Scholar]
- Clark J. A., Pagel J. E. Pollution indicator bacteria associated with municipal raw and drinking water supplies. Can J Microbiol. 1977 Apr;23(4):465–470. doi: 10.1139/m77-068. [DOI] [PubMed] [Google Scholar]
- Davenport C. V., Sparrow E. B., Gordon R. C. Fecal indicator bacteria persistence under natural conditions in an ice-covered river. Appl Environ Microbiol. 1976 Oct;32(4):527–536. doi: 10.1128/aem.32.4.527-536.1976. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Dutkaand B. J., Tobin S. E. Study on the efficiency of four procedures for enumerating coliforms in water. Can J Microbiol. 1976 May;22(5):630–635. doi: 10.1139/m76-093. [DOI] [PubMed] [Google Scholar]
- Evans T. M., LeChevallier M. W., Waarvick C. E., Seidler R. J. Coliform species recovered from untreated surface water and drinking water by the membrane filter, standard, and modified most-probable-number techniques. Appl Environ Microbiol. 1981 Mar;41(3):657–663. doi: 10.1128/aem.41.3.657-663.1981. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Evans T. M., Waarvick C. E., Seidler R. J., LeChevallier M. W. Failure of the most-probable-number technique to detect coliforms in drinking water and raw water supplies. Appl Environ Microbiol. 1981 Jan;41(1):130–138. doi: 10.1128/aem.41.1.130-138.1981. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Geldreich E. E., Jeter H. L., Winter J. A. Technical considerations in applying the membrane filter procedure. Health Lab Sci. 1967 Apr;4(2):113–125. [PubMed] [Google Scholar]
- Grabow W. O., du Preez M. Comparison of m-Endo LES, MacConkey, and Teepol media for membrane filtration counting of total coliform bacteria in water. Appl Environ Microbiol. 1979 Sep;38(3):351–358. doi: 10.1128/aem.38.3.351-358.1979. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Schiff L. J., Morrison S. M., Mayeux J. V. Synergistic false-positive coliform reaction on M-Endo MF medium. Appl Microbiol. 1970 Nov;20(5):778–781. doi: 10.1128/am.20.5.778-781.1970. [DOI] [PMC free article] [PubMed] [Google Scholar]