Abstract
Verification of membrane filter total coliform colonies was compared in lauryl tryptose broth, and m-LAC broth primary media and brilliant green-lactose-bile broth and EC broth secondary media. Verification in m-LAC broth yielded the greatest number of aerogenic isolates for both untreated surface water and drinking water samples. Verification in brilliant green-lactose-bile broth increased the number of false-negative reactions. At least 90% of the isolates aerogenic in primary verification media and anaerogenic in brilliant green-lactose-bile broth were representative of the coliform genera. The addition of a resuscitation step in the membrane filter technique did not yield greater numbers of verified coliforms per sample. Verification of both typical and atypical colonies in m-LAC broth resulted in a 10-fold increase in coliform numbers from untreated surface water. With drinking water, verification of both colony types resulted in an increase from less than 1 coliform per 100 ml to greater than 1/100 ml. A single-step verification in m-LAC broth is proposed as a more rapid and sensitive coliform verification procedure than the standard technique.
Full text
PDF![1144](https://cdn.ncbi.nlm.nih.gov/pmc/blobs/8a59/243881/02011377ff45/aem00198-0074.png)
![1145](https://cdn.ncbi.nlm.nih.gov/pmc/blobs/8a59/243881/a5e0644b16ee/aem00198-0075.png)
![1146](https://cdn.ncbi.nlm.nih.gov/pmc/blobs/8a59/243881/332155768945/aem00198-0076.png)
![1147](https://cdn.ncbi.nlm.nih.gov/pmc/blobs/8a59/243881/3b5a4b04a182/aem00198-0077.png)
![1148](https://cdn.ncbi.nlm.nih.gov/pmc/blobs/8a59/243881/6512698dea4d/aem00198-0078.png)
![1149](https://cdn.ncbi.nlm.nih.gov/pmc/blobs/8a59/243881/7fd881eafc60/aem00198-0079.png)
![1150](https://cdn.ncbi.nlm.nih.gov/pmc/blobs/8a59/243881/0fdb1b400ed8/aem00198-0080.png)
![1151](https://cdn.ncbi.nlm.nih.gov/pmc/blobs/8a59/243881/97f581e95656/aem00198-0081.png)
Selected References
These references are in PubMed. This may not be the complete list of references from this article.
- CHAMBERS C. W. Relationship of coliform bacteria to gas production in media containing lactose. Public Health Rep. 1950 May 12;65(19):619–627. [PMC free article] [PubMed] [Google Scholar]
- Clark J. A., Pagel J. E. Pollution indicator bacteria associated with municipal raw and drinking water supplies. Can J Microbiol. 1977 Apr;23(4):465–470. doi: 10.1139/m77-068. [DOI] [PubMed] [Google Scholar]
- Davenport C. V., Sparrow E. B., Gordon R. C. Fecal indicator bacteria persistence under natural conditions in an ice-covered river. Appl Environ Microbiol. 1976 Oct;32(4):527–536. doi: 10.1128/aem.32.4.527-536.1976. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Dutkaand B. J., Tobin S. E. Study on the efficiency of four procedures for enumerating coliforms in water. Can J Microbiol. 1976 May;22(5):630–635. doi: 10.1139/m76-093. [DOI] [PubMed] [Google Scholar]
- Evans T. M., LeChevallier M. W., Waarvick C. E., Seidler R. J. Coliform species recovered from untreated surface water and drinking water by the membrane filter, standard, and modified most-probable-number techniques. Appl Environ Microbiol. 1981 Mar;41(3):657–663. doi: 10.1128/aem.41.3.657-663.1981. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Evans T. M., Waarvick C. E., Seidler R. J., LeChevallier M. W. Failure of the most-probable-number technique to detect coliforms in drinking water and raw water supplies. Appl Environ Microbiol. 1981 Jan;41(1):130–138. doi: 10.1128/aem.41.1.130-138.1981. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Geldreich E. E., Jeter H. L., Winter J. A. Technical considerations in applying the membrane filter procedure. Health Lab Sci. 1967 Apr;4(2):113–125. [PubMed] [Google Scholar]
- Grabow W. O., du Preez M. Comparison of m-Endo LES, MacConkey, and Teepol media for membrane filtration counting of total coliform bacteria in water. Appl Environ Microbiol. 1979 Sep;38(3):351–358. doi: 10.1128/aem.38.3.351-358.1979. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Schiff L. J., Morrison S. M., Mayeux J. V. Synergistic false-positive coliform reaction on M-Endo MF medium. Appl Microbiol. 1970 Nov;20(5):778–781. doi: 10.1128/am.20.5.778-781.1970. [DOI] [PMC free article] [PubMed] [Google Scholar]