Abstract
Surgical gloves were collected after day-time operations for a 4-week period. Glove punctures were located by inflating each glove with compressed air and immersing the inflated glove in water. During the period of the study 681 surgical operations were performed. A total of 3790 gloves was collected, 334 gloves (8.8%) had perforations at the end of the surgical procedure. Defects occurred in one or more gloves in 32.0% of all operations.
Full text
PDFSelected References
These references are in PubMed. This may not be the complete list of references from this article.
- Church J., Sanderson P. Surgical glove punctures. J Hosp Infect. 1980 Mar;1(1):84–84. doi: 10.1016/0195-6701(80)90036-5. [DOI] [PubMed] [Google Scholar]
- Furuhashi M., Miyamae T. Effect of pre-operative hand scrubbing and influence of pinholes appearing in surgical rubber gloves during operation. Bull Tokyo Med Dent Univ. 1979 Jun;26(2):73–80. [PubMed] [Google Scholar]
- Nakazawa M., Sato K., Mizuno K. Incidence of perforations in rubber gloves during ophthalmic surgery. Ophthalmic Surg. 1984 Mar;15(3):236–240. [PubMed] [Google Scholar]