Skip to main content
Annals of The Royal College of Surgeons of England logoLink to Annals of The Royal College of Surgeons of England
. 1995 May;77(3):224–226.

Use of hand-held Doppler to identify 'difficult' forearm veins for cannulation.

M S Whiteley 1, B Y Chang 1, H P Marsh 1, A R Williams 1, H C Manton 1, M Horrocks 1
PMCID: PMC2502093  PMID: 7598423

Abstract

Intravenous cannulation is a necessary procedure in many hospital patients. Some patients are regarded as having 'impossible' veins that are invisible and impalpable despite venous tourniquet. We investigated the use of a hand-held Doppler to identify veins suitable for percutaneous cannulation in such patients. A total of 24 arms in 12 patient volunteers with invisible and impalpable forearm veins was studied by squeezing the ipsilateral hand and using a hand-held 8 MHz Doppler probe on the forearm. Each venous signal was noted and the loudest chosen. Classification as 'good' or 'poor' was made on signal strength. The best signal was then mapped and the direction was indicated by a line on the skin. Each forearm was examined using a colour-flow Duplex. All veins were noted and diameters measured with and without tourniquet. These results were compared with the best veins found by hand-held Doppler. In all, 23 (96%) arms had the largest vein correctly identified by the hand-held Doppler. All 19 (100%) described as 'good' on signal had a diameter of 2.0-4.2 mm (mean 3.2 mm). All 4 (100%) described as 'poor' on Doppler signal had diameters of 1.4-1.7 mm (mean 1.6 mm). Hand-held Doppler, used as described, can accurately identify forearm veins larger than 2.0 mm in diameter in patients with invisible and impalpable veins with venous tourinquet. These veins should be amenable to percutaneous cannulation.

Full text

PDF
225

Images in this article

Selected References

These references are in PubMed. This may not be the complete list of references from this article.

  1. Maher J. J., Dougherty J. M. Radial artery cannulation guided by Doppler ultrasound. Am J Emerg Med. 1989 May;7(3):260–262. doi: 10.1016/0735-6757(89)90165-4. [DOI] [PubMed] [Google Scholar]
  2. Nagabhushan S., Colella J. J., Jr, Wagner R. Use of Doppler ultrasound in performing percutaneous cannulation of the radial artery. Crit Care Med. 1976 Nov-Dec;4(6):327–327. doi: 10.1097/00003246-197611000-00011. [DOI] [PubMed] [Google Scholar]

Articles from Annals of The Royal College of Surgeons of England are provided here courtesy of The Royal College of Surgeons of England

RESOURCES