. 1992 Feb;30(2):495–496. doi: 10.1128/jcm.30.2.495-496.1992

Nonvalue of terminal aerobic subculture of unvented Roche Columbia broth blood culture bottles.

P P Bourbeau 1, B J Heiter 1, D W Naumovitz 1
PMCID: PMC265084  PMID: 1537922

Abstract

This study evaluated the need for a terminal aerobic blind subculture of unvented Roche Columbia broth. Only 2 of 2,871 bottles subcultured grew clinically significant organisms that were not also found in another blood culture. We conclude that in our tertiary care institution, blind subcultures of Roche Columbia broths are unwarranted.

Full text

PDF
496

Selected References

These references are in PubMed. This may not be the complete list of references from this article.

  1. Henry N. K., Grewell C. M., McLimans C. A., Washington J. A., 2nd Comparison of the Roche Septi-Chek blood culture bottle with a brain heart infusion biphasic medium bottle and with a tryptic soy broth bottle. J Clin Microbiol. 1984 Mar;19(3):315–317. doi: 10.1128/jcm.19.3.315-317.1984. [DOI] [PMC free article] [PubMed] [Google Scholar]
  2. Henry N. K., Washington J. A., 2nd Initial detection of bacteremia by subculture of unvented tryptic soy broth blood culture bottles. Diagn Microbiol Infect Dis. 1984 Apr;2(2):107–111. doi: 10.1016/0732-8893(84)90005-1. [DOI] [PubMed] [Google Scholar]
  3. Kiehn T. E., Wong B., Edwards F. F., Armstrong D. Routine aerobic terminal subculturing of blood cultures in a cancer hospital. J Clin Microbiol. 1983 Oct;18(4):885–889. doi: 10.1128/jcm.18.4.885-889.1983. [DOI] [PMC free article] [PubMed] [Google Scholar]
  4. Kim M. J., Gottschall R. L., Schwabe L. D., Randall E. L. Effect of agitation and frequent subculturing on recovery of aerobic and facultative pathogens by Roche Septi-Chek and BACTEC blood culture systems. J Clin Microbiol. 1987 Feb;25(2):312–315. doi: 10.1128/jcm.25.2.312-315.1987. [DOI] [PMC free article] [PubMed] [Google Scholar]
  5. Pfaller M. A., Sibley T. K., Westfall L. M., Hoppe-Bauer J. E., Keating M. A., Murray P. R. Clinical laboratory comparison of a slide blood culture system with a conventional broth system. J Clin Microbiol. 1982 Sep;16(3):525–530. doi: 10.1128/jcm.16.3.525-530.1982. [DOI] [PMC free article] [PubMed] [Google Scholar]
  6. Pfaller M. A., Westfall L. M., Murray P. R. Value of routine aerobic subculturing of unvented blood culture bottles. J Clin Microbiol. 1983 Apr;17(4):601–604. doi: 10.1128/jcm.17.4.601-604.1983. [DOI] [PMC free article] [PubMed] [Google Scholar]

Articles from Journal of Clinical Microbiology are provided here courtesy of American Society for Microbiology (ASM)