Skip to main content
Journal of Clinical Microbiology logoLink to Journal of Clinical Microbiology
. 1992 May;30(5):1267–1270. doi: 10.1128/jcm.30.5.1267-1270.1992

Evaluation of the 4-hour RapID NF Plus method for identification of 345 gram-negative nonfermentative rods.

T T Kitch 1, M R Jacobs 1, P C Appelbaum 1
PMCID: PMC265262  PMID: 1583129

Abstract

The ability of the RapID NF Plus system (Innovative Diagnostic Systems, Inc., Atlanta, Ga.) to identify 345 nonfermentative gram-negative rods was evaluated. Kits were inoculated with no. 1 McFarland suspensions, and reactions were interpreted after a 4-h incubation at 35 degrees C. Overall, the method correctly identified 311 strains (90.1%) without additional tests and 21 strains (6.1%) with additional tests, and 13 strains (3.8%) were misidentified. Five of 13 misidentified strains were Alcaligenes faecalis-Alcaligenes odorans misidentified as Alcaligenes xylosoxidans; however, all strains were xylose negative but nitrate positive and could have been A. faecalis group I-Alcaligenes piechaudii. The system does not differentiate between Pseudomonas fluorescens and Pseudomonas putida, and all Acinetobacter species are identified as Acetinobacter calcoaceticus. Additionally, no subspecies differentiation is made between A. xylosoxidans subsp. xylosoxidans and A. xylosoxidans subsp. denitrificans. All strains of the former Flavobacterium group IIb are identified as Flavobacterium indologenes-Flavobacterium gleum, and no species identification of the genus Methylobacterium is attempted. The system is easy to set up and interpret and provides an accurate commercial nonautomated method for same-day identification of gram-negative nonfermenters.

Full text

PDF
1268

Selected References

These references are in PubMed. This may not be the complete list of references from this article.

  1. Appelbaum P. C., Leathers D. J. Evaluation of the rapid NFT system for identification of gram-negative, nonfermenting rods. J Clin Microbiol. 1984 Oct;20(4):730–734. doi: 10.1128/jcm.20.4.730-734.1984. [DOI] [PMC free article] [PubMed] [Google Scholar]
  2. Appelbaum P. C., Stavitz J., Bentz M. S., von Kuster L. C. Four methods for identification of gram-negative nonfermenting rods: organisms more commonly encountered in clinical specimens. J Clin Microbiol. 1980 Aug;12(2):271–278. doi: 10.1128/jcm.12.2.271-278.1980. [DOI] [PMC free article] [PubMed] [Google Scholar]
  3. Kelly M. T., Matsen J. M., Morello J. A., Smith P. B., Tilton R. C. Collaborative clinical evaluation of the Autobac IDX system for identification of gram-negative bacilli. J Clin Microbiol. 1984 Apr;19(4):529–533. doi: 10.1128/jcm.19.4.529-533.1984. [DOI] [PMC free article] [PubMed] [Google Scholar]
  4. Kämpfer P., Dott W. Evaluation of the Titertek-NF system for identification of gram-negative nonfermentative and oxidase-positive fermentative bacteria. J Clin Microbiol. 1989 Jun;27(6):1201–1205. doi: 10.1128/jcm.27.6.1201-1205.1989. [DOI] [PMC free article] [PubMed] [Google Scholar]
  5. Ling J. M., Zhang L. C., Hui Y. W., French G. L. Evaluation of Cathra system for identifying gram negative aerobic bacteria. J Clin Pathol. 1990 Jul;43(7):587–590. doi: 10.1136/jcp.43.7.587. [DOI] [PMC free article] [PubMed] [Google Scholar]
  6. Miller J. M., Rhoden D. L. Preliminary evaluation of Biolog, a carbon source utilization method for bacterial identification. J Clin Microbiol. 1991 Jun;29(6):1143–1147. doi: 10.1128/jcm.29.6.1143-1147.1991. [DOI] [PMC free article] [PubMed] [Google Scholar]
  7. Osterhout G. J., Shull V. H., Dick J. D. Identification of clinical isolates of gram-negative nonfermentative bacteria by an automated cellular fatty acid identification system. J Clin Microbiol. 1991 Sep;29(9):1822–1830. doi: 10.1128/jcm.29.9.1822-1830.1991. [DOI] [PMC free article] [PubMed] [Google Scholar]
  8. Plorde J. J., Gates J. A., Carlson L. G., Tenover F. C. Critical evaluation of the AutoMicrobic system gram-negative identification card for identification of glucose-nonfermenting gram-negative rods. J Clin Microbiol. 1986 Feb;23(2):251–257. doi: 10.1128/jcm.23.2.251-257.1986. [DOI] [PMC free article] [PubMed] [Google Scholar]
  9. Rhoden D. L., Schable B., Smith P. B. Evaluation of PASCO MIC-ID system for identifying gram-negative bacilli. J Clin Microbiol. 1987 Dec;25(12):2363–2366. doi: 10.1128/jcm.25.12.2363-2366.1987. [DOI] [PMC free article] [PubMed] [Google Scholar]
  10. Rhoden D. L., Smith P. B., Baker C. N., Schable B. autoSCAN-4 system for identification of gram-negative bacilli. J Clin Microbiol. 1985 Dec;22(6):915–918. doi: 10.1128/jcm.22.6.915-918.1985. [DOI] [PMC free article] [PubMed] [Google Scholar]
  11. Tenover F. C., Mizuki T. S., Carlson L. G. Evaluation of autoSCAN-W/A automated microbiology system for the identification of non-glucose-fermenting gram-negative bacilli. J Clin Microbiol. 1990 Jul;28(7):1628–1634. doi: 10.1128/jcm.28.7.1628-1634.1990. [DOI] [PMC free article] [PubMed] [Google Scholar]

Articles from Journal of Clinical Microbiology are provided here courtesy of American Society for Microbiology (ASM)

RESOURCES