Skip to main content
Journal of Clinical Microbiology logoLink to Journal of Clinical Microbiology
. 1988 Aug;26(8):1575–1579. doi: 10.1128/jcm.26.8.1575-1579.1988

Human-isotype-specific enzyme immunoassay for antibodies to pneumococcal polysaccharides.

G N Shyamala 1, D M Roberton 1, C S Hosking 1
PMCID: PMC266663  PMID: 3049660

Abstract

A simple enzyme immunoassay has been developed to allow the quantitation of the human response to immunization with pneumococcal polysaccharide. The assay uses the 14-valent vaccine (Pneumovax) as a convenient antigen to adsorb to the solid-phase microdilution plate wells and commercially available isotype-specific antibody conjugates. The results have been expressed as arbitrary pneumococcal polysaccharide antibody units by reading off a standard curve constructed by using heterogeneous pooled serum. All nonimmunized subjects tested had immunoglobulin G (IgG) antibodies present in serum. All six control subjects who were immunized with Pneumovax demonstrated an IgG response, and the majority responded with a rise in IgA- and IgM-specific antibody concentrations at a mean of 6 weeks postimmunization. Five out of six cord sera tested contained IgG antibodies only, which were present in concentrations similar to those seen in adults, whereas in 6- to 12-month-old infants only low levels of IgG and IgM and no IgA antibodies were detected. Serum taken from 10 hypogammaglobulinemic patients immediately prior to infusion of immunoglobulin showed low to negative IgG antibody concentrations, and no IgA or IgM antibody was present.

Full text

PDF
1576

Selected References

These references are in PubMed. This may not be the complete list of references from this article.

  1. Barrett D. J., Ammann A. J., Stenmark S., Wara D. W. Immunoglobulin G and M antibodies to pneumococcal polysaccharides detected by enzyme-linked immunosorbent assay. Infect Immun. 1980 Feb;27(2):411–417. doi: 10.1128/iai.27.2.411-417.1980. [DOI] [PMC free article] [PubMed] [Google Scholar]
  2. Berntsson E., Broholm K. A., Kaijser B. Serological diagnosis of pneumococcal disease with enzyme-linked immunosorbent assay (ELISA). Scand J Infect Dis. 1978;10(3):177–181. doi: 10.3109/inf.1978.10.issue-3.04. [DOI] [PubMed] [Google Scholar]
  3. Borsos T., Rapp H. J. Complement fixation on cell surfaces by 19S and 7S antibodies. Science. 1965 Oct 22;150(3695):505–506. doi: 10.1126/science.150.3695.505. [DOI] [PubMed] [Google Scholar]
  4. Callahan L. T., 3rd, Woodhour A. F., Meeker J. B., Hilleman M. R. Enzyme-linked immunosorbent assay for measurement of antibodies against pneumococcal polysaccharide antigens: comparison with radioimmunoassay. J Clin Microbiol. 1979 Oct;10(4):459–463. doi: 10.1128/jcm.10.4.459-463.1979. [DOI] [PMC free article] [PubMed] [Google Scholar]
  5. Carlson B. A., Giebink G. S., Spika J. S., Gray E. D. Measurement of immunoglobulin G and M antibodies to type 3 pneumococcal capsular polysaccharide by enzyme-linked immunosorbent assay. J Clin Microbiol. 1982 Jul;16(1):63–69. doi: 10.1128/jcm.16.1.63-69.1982. [DOI] [PMC free article] [PubMed] [Google Scholar]
  6. Chudwin D. S., Wara D. W., Schiffman G., Artrip S. G., Ammann A. J. Maternal-fetal transfer of pneumococcal capsular polysaccharide antibodies. Am J Dis Child. 1985 Apr;139(4):378–380. doi: 10.1001/archpedi.1985.02140060060029. [DOI] [PubMed] [Google Scholar]
  7. Eckman I., Robbins J. B., Van den Hamer C. J., Lentz J., Scheinberg I. H. Automation of a quantitative immunochemical microanalysis of human serum transferrin: a model system. Clin Chem. 1970 Jul;16(7):558–561. [PubMed] [Google Scholar]
  8. Giebink G. S., Foker J. E., Kim Y., Schiffman G. Serum antibody and opsonic responses to vaccination with pneumococcal capsular polysaccharide in normal and splenectomized children. J Infect Dis. 1980 Mar;141(3):404–412. doi: 10.1093/infdis/141.3.404. [DOI] [PubMed] [Google Scholar]
  9. Giebink G. S., Le C. T., Spika J. S. Summarized vs. type-specific analysis of antibody to pneumococcal capsular polysaccharides. Rev Infect Dis. 1981 Mar-Apr;3 (Suppl):S43–S50. doi: 10.1093/clinids/3.supplement_1.s43. [DOI] [PubMed] [Google Scholar]
  10. Hetherington S. V., Giebink G. S. Opsonic activity of immunoglobulin prepared for intravenous use. J Lab Clin Med. 1984 Dec;104(6):977–986. [PubMed] [Google Scholar]
  11. Hosea S. W., Burch C. G., Brown E. J., Berg R. A., Frank M. M. Impaired immune response of splenectomised patients to polyvalent pneumococcal vaccine. Lancet. 1981 Apr 11;1(8224):804–807. doi: 10.1016/s0140-6736(81)92681-7. [DOI] [PubMed] [Google Scholar]
  12. Koskela M., Leinonen M. Comparison of ELISA and RIA for measurement of pneumococcal antibodies before and after vaccination with 14-valent pneumococcal capsular polysaccharide vaccine. J Clin Pathol. 1981 Jan;34(1):93–98. doi: 10.1136/jcp.34.1.93. [DOI] [PMC free article] [PubMed] [Google Scholar]
  13. Koskela M. Serum antibodies to pneumococcal C polysaccharide in children: response to acute pneumococcal otitis media or to vaccination. Pediatr Infect Dis J. 1987 Jun;6(6):519–526. doi: 10.1097/00006454-198706000-00006. [DOI] [PubMed] [Google Scholar]
  14. Landesman S. H., Schiffman G. Assessment of the antibody response to pneumococcal vaccine in high-risk populations. Rev Infect Dis. 1981 Mar-Apr;3 (Suppl):S184–S197. doi: 10.1093/clinids/3.supplement_1.s184. [DOI] [PubMed] [Google Scholar]
  15. Melville-Smith M., Sheffield F. Enzyme linked immunosorbent assays for the estimation of immune responses to pneumococcal polysaccharides. J Biol Stand. 1980;8(4):317–322. doi: 10.1016/s0092-1157(80)80010-2. [DOI] [PubMed] [Google Scholar]
  16. Pedersen F. K. Antibody response to pneumococcal vaccine in splenectomized children. Acta Pathol Microbiol Immunol Scand C. 1983 Apr;91(2):169–180. [PubMed] [Google Scholar]
  17. Pedersen F. K., Henrichsen J. Detection of antibodies to pneumococcal capsular polysaccharides by enzyme-linked immunosorbent assay. J Clin Microbiol. 1982 Mar;15(3):372–378. doi: 10.1128/jcm.15.3.372-378.1982. [DOI] [PMC free article] [PubMed] [Google Scholar]
  18. Russell H., Edwards L. R., Wortham E. W., Facklam R. R. Enzyme-linked immunosorbent assay for detection of antibodies against Streptococcus pneumoniae capsular polysaccharides. J Clin Microbiol. 1980 Feb;11(2):198–199. doi: 10.1128/jcm.11.2.198-199.1980. [DOI] [PMC free article] [PubMed] [Google Scholar]
  19. Stemshorn B. W., Buckley D. J., St Amour G., Lin C. S., Duncan J. R. A computer-interfaced photometer and systematic spacing of duplicates to control within-plate enzyme-immunoassay variation. J Immunol Methods. 1983 Jul 29;61(3):367–375. doi: 10.1016/0022-1759(83)90233-8. [DOI] [PubMed] [Google Scholar]
  20. Turner K. J., Carter P. M., Hosking C. S., Finger W. K. The Australian reference preparation of human serum immunoglobulins. Aust J Exp Biol Med Sci. 1980 Aug;58(4):351–356. doi: 10.1038/icb.1980.34. [DOI] [PubMed] [Google Scholar]
  21. Winkelstein J. A. Opsonins: their function, identity, and clinical significance. J Pediatr. 1973 May;82(5):747–753. doi: 10.1016/s0022-3476(73)80062-9. [DOI] [PubMed] [Google Scholar]

Articles from Journal of Clinical Microbiology are provided here courtesy of American Society for Microbiology (ASM)

RESOURCES