Comparison of the lysis-centrifugation and agitated biphasic blood culture systems for detection of fungemia.

P R Murray 1
PMCID: PMC269710  PMID: 1993772

Abstract

Although the detection of fungemia has been improved by the use of vented or biphasic blood culture bottles, the best recovery and earliest detection have been reported in the Isolator lysis-centrifugation system. It was recently demonstrated that improved detection of both bacteria and fungi was accomplished by mechanically agitating blood culture bottles for the first 24 h of incubation. In this study the detection of fungemia by use of the Isolator system was compared with that of an agitated biphasic system. A total of 182 fungi were isolated from blood specimens inoculated into both culture systems. No difference in the overall recovery of fungi or individual species of yeasts was observed between the two systems. However, all seven isolates of Histoplasma capsulatum were recovered in the Isolator system only. The time required to detect fungemia with each of the two systems was also compared. No statistically significant difference was observed. From the data collected during this 18-month study, it can be concluded that the overall recovery and time of detection of yeasts are equivalent in the lysis-centrifugation system and the agitated biphasic blood culture system. The lysis-centrifugation system is still superior for the detection of filamentous fungi such as H. capsulatum.

Full text

PDF
97

Selected References

These references are in PubMed. This may not be the complete list of references from this article.

  1. Basille B. A., Easley K. A., Hall G. S., Washington J. A., 2nd Comparison of conventional and revised isolator blood culture tubes. J Clin Microbiol. 1987 Nov;25(11):2221–2222. doi: 10.1128/jcm.25.11.2221-2222.1987. [DOI] [PMC free article] [PubMed] [Google Scholar]
  2. Bille J., Edson R. S., Roberts G. D. Clinical evaluation of the lysis-centrifugation blood culture system for the detection of fungemia and comparison with a conventional biphasic broth blood culture system. J Clin Microbiol. 1984 Feb;19(2):126–128. doi: 10.1128/jcm.19.2.126-128.1984. [DOI] [PMC free article] [PubMed] [Google Scholar]
  3. Bille J., Roberts G. D., Washington J. A., 2nd Retrospective comparison of three blood culture media for the recovery of yeasts from clinical specimens. Eur J Clin Microbiol. 1983 Feb;2(1):22–25. doi: 10.1007/BF02019918. [DOI] [PubMed] [Google Scholar]
  4. Bille J., Stockman L., Roberts G. D., Horstmeier C. D., Ilstrup D. M. Evaluation of a lysis-centrifugation system for recovery of yeasts and filamentous fungi from blood. J Clin Microbiol. 1983 Sep;18(3):469–471. doi: 10.1128/jcm.18.3.469-471.1983. [DOI] [PMC free article] [PubMed] [Google Scholar]
  5. Brannon P., Kiehn T. E. Clinical comparison of lysis-centrifugation and radiometric resin systems for blood culture. J Clin Microbiol. 1986 Nov;24(5):886–887. doi: 10.1128/jcm.24.5.886-887.1986. [DOI] [PMC free article] [PubMed] [Google Scholar]
  6. Brannon P., Kiehn T. E. Large-scale clinical comparison of the lysis-centrifugation and radiometric systems for blood culture. J Clin Microbiol. 1985 Dec;22(6):951–954. doi: 10.1128/jcm.22.6.951-954.1985. [DOI] [PMC free article] [PubMed] [Google Scholar]
  7. Guerra-Romero L., Edson R. S., Cockerill F. R., 3rd, Horstmeier C. D., Roberts G. D. Comparison of Du Pont Isolator and Roche Septi-Chek for detection of fungemia. J Clin Microbiol. 1987 Sep;25(9):1623–1625. doi: 10.1128/jcm.25.9.1623-1625.1987. [DOI] [PMC free article] [PubMed] [Google Scholar]
  8. Harkness J. L., Hall M., Ilstrup D. M., Washington J. A., 2nd Effects of atmosphere of incubation and of routine subcultures on detection of bacteremia in vacuum blood culture bottles. J Clin Microbiol. 1975 Oct;2(4):296–299. doi: 10.1128/jcm.2.4.296-299.1975. [DOI] [PMC free article] [PubMed] [Google Scholar]
  9. Hawkins B. L., Peterson E. M., de la Maza L. M. Improvement of positive blood culture detection by agitation. Diagn Microbiol Infect Dis. 1986 Sep;5(3):207–213. doi: 10.1016/0732-8893(86)90003-9. [DOI] [PubMed] [Google Scholar]
  10. Henry N. K., Grewell C. M., Van Grevenhof P. E., Ilstrup D. M., Washington J. A., 2nd Comparison of lysis-centrifugation with a biphasic blood culture medium for the recovery of aerobic and facultatively anaerobic bacteria. J Clin Microbiol. 1984 Sep;20(3):413–416. doi: 10.1128/jcm.20.3.413-416.1984. [DOI] [PMC free article] [PubMed] [Google Scholar]
  11. Henry N. K., McLimans C. A., Wright A. J., Thompson R. L., Wilson W. R., Washington J. A., 2nd Microbiological and clinical evaluation of the isolator lysis-centrifugation blood culture tube. J Clin Microbiol. 1983 May;17(5):864–869. doi: 10.1128/jcm.17.5.864-869.1983. [DOI] [PMC free article] [PubMed] [Google Scholar]
  12. Kellogg J. A., Manzella J. P., McConville J. H. Clinical laboratory comparison of the 10-ml isolator blood culture system with BACTEC radiometric blood culture media. J Clin Microbiol. 1984 Oct;20(4):618–623. doi: 10.1128/jcm.20.4.618-623.1984. [DOI] [PMC free article] [PubMed] [Google Scholar]
  13. Kelly M. T., Roberts F. J., Henry D., Geere I., Smith J. A. Clinical comparison of isolator and BACTEC 660 resin media for blood culture. J Clin Microbiol. 1990 Sep;28(9):1925–1927. doi: 10.1128/jcm.28.9.1925-1927.1990. [DOI] [PMC free article] [PubMed] [Google Scholar]
  14. Kiehn T. E., Wong B., Edwards F. F., Armstrong D. Comparative recovery of bacteria and yeasts from lysis-centrifugation and a conventional blood culture system. J Clin Microbiol. 1983 Aug;18(2):300–304. doi: 10.1128/jcm.18.2.300-304.1983. [DOI] [PMC free article] [PubMed] [Google Scholar]
  15. Kim M. J., Gottschall R. L., Schwabe L. D., Randall E. L. Effect of agitation and frequent subculturing on recovery of aerobic and facultative pathogens by Roche Septi-Chek and BACTEC blood culture systems. J Clin Microbiol. 1987 Feb;25(2):312–315. doi: 10.1128/jcm.25.2.312-315.1987. [DOI] [PMC free article] [PubMed] [Google Scholar]
  16. Pfaller M. A., Sibley T. K., Westfall L. M., Hoppe-Bauer J. E., Keating M. A., Murray P. R. Clinical laboratory comparison of a slide blood culture system with a conventional broth system. J Clin Microbiol. 1982 Sep;16(3):525–530. doi: 10.1128/jcm.16.3.525-530.1982. [DOI] [PMC free article] [PubMed] [Google Scholar]
  17. Reimer L. G., Reller L. B., Mirrett S. Controlled comparison of a new Becton Dickinson agar slant blood culture system with Roche Septi-Chek for the detection of bacteremia and fungemia. J Clin Microbiol. 1989 Dec;27(12):2637–2639. doi: 10.1128/jcm.27.12.2637-2639.1989. [DOI] [PMC free article] [PubMed] [Google Scholar]
  18. Roberts G. D., Horstmeier C., Hall M., Washington J. A., 2nd Recovery of yeast from vented blood culture bottles. J Clin Microbiol. 1975 Jul;2(1):18–20. doi: 10.1128/jcm.2.1.18-20.1975. [DOI] [PMC free article] [PubMed] [Google Scholar]
  19. Roberts G. D., Washington J. A., 2nd Detection of fungi in blood cultures. J Clin Microbiol. 1975 Mar;1(3):309–310. doi: 10.1128/jcm.1.3.309-310.1975. [DOI] [PMC free article] [PubMed] [Google Scholar]
  20. Weinstein M. P., Mirrett S., Reimer L. G., Reller L. B. Effect of agitation and terminal subcultures on yield and speed of detection of the Oxoid Signal blood culture system versus the BACTEC radiometric system. J Clin Microbiol. 1989 Mar;27(3):427–430. doi: 10.1128/jcm.27.3.427-430.1989. [DOI] [PMC free article] [PubMed] [Google Scholar]
  21. Weinstein M. P., Reller L. B., Mirrett S., Stratton C. W., Reimer L. G., Wang W. L. Controlled evaluation of the agar-slide and radiometric blood culture systems for the detection of bacteremia and fungemia. J Clin Microbiol. 1986 Feb;23(2):221–225. doi: 10.1128/jcm.23.2.221-225.1986. [DOI] [PMC free article] [PubMed] [Google Scholar]
  22. Weinstein M. P., Reller L. B., Mirrett S., Wang W. L., Alcid D. V. Clinical comparison of an agar slide blood culture bottle with tryptic soy broth and a conventional blood culture bottle with supplemented peptone broth. J Clin Microbiol. 1985 May;21(5):815–818. doi: 10.1128/jcm.21.5.815-818.1985. [DOI] [PMC free article] [PubMed] [Google Scholar]
  23. Weinstein M. P., Reller L. B., Mirrett S., Wang W. L., Alcid D. V. Controlled evaluation of Trypticase soy broth in agar slide and conventional blood culture systems. J Clin Microbiol. 1985 Apr;21(4):626–629. doi: 10.1128/jcm.21.4.626-629.1985. [DOI] [PMC free article] [PubMed] [Google Scholar]

Articles from Journal of Clinical Microbiology are provided here courtesy of American Society for Microbiology (ASM)

RESOURCES