Skip to main content
Journal of Clinical Microbiology logoLink to Journal of Clinical Microbiology
. 1984 Apr;19(4):502–505. doi: 10.1128/jcm.19.4.502-505.1984

Evaluation of the automicrobic system for susceptibility testing of Pseudomonas aeruginosa to gentamicin, tobramycin, and amikacin.

B F Woolfrey, R T Lally, M N Ederer, C O Quall
PMCID: PMC271104  PMID: 6425360

Abstract

The AutoMicrobic system (AMS; Vitek Systems, Inc., Hazelwood, Mo.) was studied for its ability to produce accurate and precise MIC interpretations for Pseudomonas aeruginosa susceptibility to gentamicin, tobramycin, and amikacin. MICs were determined in parallel on 200 selected P. aeruginosa isolates by using the AMS discrete-integer MIC program AMS p12.ROB for interpretation of the AMS Gram-Negative General Susceptibility Urinary Card, and a reference small-integer broth microdilution test. Parallel AMS and broth microdilution MICs were also replicated for three selected strains of P. aeruginosa for which MICs were representative of the dilution test ranges. For the 200 P. aeruginosa isolates, mean AMS MICs were significantly larger than the reference test mean MICs, coefficients of variation were approximately double those of the reference test, and correlation coefficients were unacceptably low for each antimicrobial agent. MIC replication studies for the three selected P. aeruginosa strains showed comparable AMS and reference mean MICs in the lower portions of the dilution ranges, significantly higher AMS mean MICs in the upper portions, and mean coefficients of variation of 63 and 9.6%, respectively, for replicated AMS and reference MICs. These results indicate that the AMS, in its present stage of development, does not produce acceptable MIC measurements for P. aeruginosa susceptibility to gentamicin, tobramycin, and amikacin.

Full text

PDF
505

Selected References

These references are in PubMed. This may not be the complete list of references from this article.

  1. Almeida R. J., Jorgensen J. H., Johnson J. E. Evaluation of the automicrobic system gram-positive identification card for species identification of coagulase-negative staphylococci. J Clin Microbiol. 1983 Aug;18(2):438–439. doi: 10.1128/jcm.18.2.438-439.1983. [DOI] [PMC free article] [PubMed] [Google Scholar]
  2. Barry A. L., Badal R. E. Reliability of early identifications obtained with Enterobacteriaceae-plus biochemical cards in the automicrobic system. J Clin Microbiol. 1982 Aug;16(2):257–265. doi: 10.1128/jcm.16.2.257-265.1982. [DOI] [PMC free article] [PubMed] [Google Scholar]
  3. Barry A. L., Gavan T. L., Badal R. E., Telenson M. J. Sensitivity, specificity, and reproducibility of the automicrobic system (with the Enterobacteriaceae-plus biochemical card) for identifying clinical isolates of Gram- negative bacilli. J Clin Microbiol. 1982 Apr;15(4):582–588. doi: 10.1128/jcm.15.4.582-588.1982. [DOI] [PMC free article] [PubMed] [Google Scholar]
  4. Dennstedt F. E., Stager C. E., Davis J. R. Rapid method for identification and susceptibility testing of Escherichia coli bacteriuria. J Clin Microbiol. 1983 Jul;18(1):150–153. doi: 10.1128/jcm.18.1.150-153.1983. [DOI] [PMC free article] [PubMed] [Google Scholar]
  5. Dudley M., Nauschuetz W. F., Juchau S. V. Clinical evaluation of new AMS GSC plus card. Diagn Microbiol Infect Dis. 1983 Jun;1(2):139–143. doi: 10.1016/0732-8893(83)90043-3. [DOI] [PubMed] [Google Scholar]
  6. Gilbert D. N., Kutscher E., Ireland P., Barnett J. A., Sanford J. P. Effect of the concentrations of magnesium and calcium on the in-vitro susceptibility of Pseudomonas aeruginosa to gentamicin. J Infect Dis. 1971 Dec;124 (Suppl):S37–S45. doi: 10.1093/infdis/124.supplement_1.s37. [DOI] [PubMed] [Google Scholar]
  7. Goldstein J., Guarneri J. J., Della-Latta P., Scherer J. Use of the automicrobic and enteric-tek systems for identification of Enterobacteriaceae. J Clin Microbiol. 1982 Apr;15(4):654–659. doi: 10.1128/jcm.15.4.654-659.1982. [DOI] [PMC free article] [PubMed] [Google Scholar]
  8. Hamoudi A. C., Lin S. Cost analysis of the Auto Microbic system urine identification card. J Clin Microbiol. 1981 Oct;14(4):411–414. doi: 10.1128/jcm.14.4.411-414.1981. [DOI] [PMC free article] [PubMed] [Google Scholar]
  9. Hansen S. L., Freedy P. K. Concurrent comparability of automated systems and commercially prepared microdilution trays for susceptibility testing. J Clin Microbiol. 1983 May;17(5):878–886. doi: 10.1128/jcm.17.5.878-886.1983. [DOI] [PMC free article] [PubMed] [Google Scholar]
  10. Isenberg H. D., Gavan T. L., Sonnenwirth A., Taylor W. I., Washington J. A., 2nd Clinical laboratory evaluation of automated microbial detection/identification system in analysis of clinical urine specimens. J Clin Microbiol. 1979 Aug;10(2):226–230. doi: 10.1128/jcm.10.2.226-230.1979. [DOI] [PMC free article] [PubMed] [Google Scholar]
  11. Johnson J. E., Brinkley A. W. Comparison of the AutoMicrobic system and a conventional tube system for identification of nonfermentative and oxidase-positive gram-negative bacilli. J Clin Microbiol. 1982 Jan;15(1):25–27. doi: 10.1128/jcm.15.1.25-27.1982. [DOI] [PMC free article] [PubMed] [Google Scholar]
  12. Jorgensen J. H., Johnson J. E., Alexander G. A., Paxson R., Alderson G. L. Comparison of automated and rapid manual methods for the same-day identification of Enterobacteriaceae. Am J Clin Pathol. 1983 Jun;79(6):683–687. doi: 10.1093/ajcp/79.6.683. [DOI] [PubMed] [Google Scholar]
  13. Kenny M. A., Pollock H. M., Minshew B. H., Casillas E., Schoenknecht F. D. Cation components of Mueller-Hinton agar affecting testing of Pseudomonas aeruginosa susceptibility to gentamicin. Antimicrob Agents Chemother. 1980 Jan;17(1):55–62. doi: 10.1128/aac.17.1.55. [DOI] [PMC free article] [PubMed] [Google Scholar]
  14. Nicholson D. P., Koepke J. A. The Automicrobic System for urines. J Clin Microbiol. 1979 Dec;10(6):823–833. doi: 10.1128/jcm.10.6.823-833.1979. [DOI] [PMC free article] [PubMed] [Google Scholar]
  15. Reller L. B., Schoenknecht F. D., Kenny M. A., Sherris J. C. Antibiotic susceptibility testing of Pseudomonas aeruginosa: selection of a control strain and criteria for magnesium and calcium content in media. J Infect Dis. 1974 Nov;130(5):454–463. doi: 10.1093/infdis/130.5.454. [DOI] [PubMed] [Google Scholar]
  16. Ruoff K. L., Ferraro M. J., Jerz M. E., Kissling J. Automated identification of gram-positive bacteria. J Clin Microbiol. 1982 Dec;16(6):1091–1095. doi: 10.1128/jcm.16.6.1091-1095.1982. [DOI] [PMC free article] [PubMed] [Google Scholar]
  17. Smith P. B., Gavan T. L., Isenberg H. D., Sonnenwirth A., Taylor W. I., Washington J. A., 2nd, Balows A. Multi-laboratory evaluation of an automated microbial detection/identification system. J Clin Microbiol. 1978 Dec;8(6):657–666. doi: 10.1128/jcm.8.6.657-666.1978. [DOI] [PMC free article] [PubMed] [Google Scholar]
  18. Smith S. M., Cundy K. R., Gilardi G. L., Wong W. Evaluation of the AutoMicrobic system for identification of glucose-nonfermenting gram-negative rods. J Clin Microbiol. 1982 Feb;15(2):302–307. doi: 10.1128/jcm.15.2.302-307.1982. [DOI] [PMC free article] [PubMed] [Google Scholar]
  19. Woolfrey B. F., Fox J. M., Lally R. T., Quall C. O. Broth microdilution testing of Pseudomonas aeruginosa and aminoglycosides: need for employing dilutions differing by small arithmetic increments. J Clin Microbiol. 1982 Oct;16(4):663–667. doi: 10.1128/jcm.16.4.663-667.1982. [DOI] [PMC free article] [PubMed] [Google Scholar]
  20. Woolfrey B. F., Fox J. M., Quall C. O. Comparison of minimum inhibitory concentration values determined by three antimicrobic dilution methods for Pseudomonas aeruginosa. Am J Clin Pathol. 1981 Jan;75(1):39–44. doi: 10.1093/ajcp/75.1.39. [DOI] [PubMed] [Google Scholar]

Articles from Journal of Clinical Microbiology are provided here courtesy of American Society for Microbiology (ASM)

RESOURCES