Skip to main content
Journal of Clinical Microbiology logoLink to Journal of Clinical Microbiology
. 1984 May;19(5):634–638. doi: 10.1128/jcm.19.5.634-638.1984

Clinical comparison of the Isolator 1.5 microbial tube and the BACTEC radiometric system for detection of bacteremia in children.

R B Carey
PMCID: PMC271145  PMID: 6376537

Abstract

The Isolator 1.5 microbial tube (E. I. du Pont de Nemours & Co., Inc., Wilmington , Del.) was compared with the BACTEC radiometric detection system (Johnston Laboratories, Inc., Cockeysville, Md.) for the detection of bacteremia in children. The Isolator 1.5 is a blood culture system designed for small volumes of blood (0.5 to 1.5 ml). The method involves lysis of the cells of the patient and the direct plating of the entire blood lysate on agar media appropriate for the growth of fastidious microorganisms. Of 1,500 paired samples inoculated into the two systems, 68 were positive for 73 clinically significant organisms. The Isolator 1.5 recovered 81% of the positive cultures compared with 84% recovered by the BACTEC system. When paired blood samples with disproportionate volumes were excluded, the Isolator 1.5 detected 3% more positive cultures. More isolates of Streptococcus pneumoniae and Neisseria meningitidis were recovered by the Isolator 1.5, whereas Haemophilus influenzae was recovered most often in the BACTEC bottles (P greater than 0.1). The contamination rates were 8.7 and 3.1% for the Isolator 1.5 and the BACTEC system, respectively. In cultures positive by both systems, the mean time to detection was 4.1 h faster with the Isolator 1.5. The mean time to obtain isolated colonies was 26.6 h faster with the Isolator 1.5. These data indicate the potential value of the Isolator 1.5 microbial tube as a simple, rapid, and sensitive method for the detection of bacteremia in children.

Full text

PDF
637

Selected References

These references are in PubMed. This may not be the complete list of references from this article.

  1. Adeniyi-Jones C. C., Stevens D. L., Rasquinha E. S. False no-growth blood cultures in pneumococcal pneumonia. J Clin Microbiol. 1980 Oct;12(4):572–575. doi: 10.1128/jcm.12.4.572-575.1980. [DOI] [PMC free article] [PubMed] [Google Scholar]
  2. Bille J., Stockman L., Roberts G. D., Horstmeier C. D., Ilstrup D. M. Evaluation of a lysis-centrifugation system for recovery of yeasts and filamentous fungi from blood. J Clin Microbiol. 1983 Sep;18(3):469–471. doi: 10.1128/jcm.18.3.469-471.1983. [DOI] [PMC free article] [PubMed] [Google Scholar]
  3. Dorn G. L., Burson G. G., Haynes J. R. Blood culture technique based on centrifugation: clinical evaluation. J Clin Microbiol. 1976 Mar;3(3):258–263. doi: 10.1128/jcm.3.3.258-263.1976. [DOI] [PMC free article] [PubMed] [Google Scholar]
  4. Dorn G. L., Land G. A., Wilson G. E. Improved blood culture technique based on centrifugation: clinical evaluation. J Clin Microbiol. 1979 Mar;9(3):391–396. doi: 10.1128/jcm.9.3.391-396.1979. [DOI] [PMC free article] [PubMed] [Google Scholar]
  5. Dorn G. L., Smith K. New centrifugation blood culture device. J Clin Microbiol. 1978 Jan;7(1):52–54. doi: 10.1128/jcm.7.1.52-54.1978. [DOI] [PMC free article] [PubMed] [Google Scholar]
  6. Edberg S. C., Edberg M. K. Inactivation of the polyanionic detergent sodium polyanetholsulfonate by hemoglobin. J Clin Microbiol. 1983 Nov;18(5):1047–1050. doi: 10.1128/jcm.18.5.1047-1050.1983. [DOI] [PMC free article] [PubMed] [Google Scholar]
  7. Eng J. Effect of sodium polyanethol sulfonate in blood cultures. J Clin Microbiol. 1975 Feb;1(2):119–123. doi: 10.1128/jcm.1.2.119-123.1975. [DOI] [PMC free article] [PubMed] [Google Scholar]
  8. Kelly M. T., Buck G. E., Fojtasek M. F. Evaluation of a lysis-centrifugation and biphasic bottle blood culture system during routine use. J Clin Microbiol. 1983 Sep;18(3):554–557. doi: 10.1128/jcm.18.3.554-557.1983. [DOI] [PMC free article] [PubMed] [Google Scholar]
  9. McLaughlin J. C., Hamilton P., Scholes J. V., Bartlett R. C. Clinical laboratory comparison of lysis-centrifugation and BACTEC radiometric blood culture techniques. J Clin Microbiol. 1983 Nov;18(5):1027–1031. doi: 10.1128/jcm.18.5.1027-1031.1983. [DOI] [PMC free article] [PubMed] [Google Scholar]
  10. Santosham M., Moxon E. R. Detection and quantitation of bacteremia in childhood. J Pediatr. 1977 Nov;91(5):719–721. doi: 10.1016/s0022-3476(77)81022-6. [DOI] [PubMed] [Google Scholar]
  11. Tenney J. H., Reller L. B., Mirrett S., Wang W. L., Weinstein M. P. Controlled evaluation of the volume of blood cultured in detection of bacteremia and fungemia. J Clin Microbiol. 1982 Apr;15(4):558–561. doi: 10.1128/jcm.15.4.558-561.1982. [DOI] [PMC free article] [PubMed] [Google Scholar]