Skip to main content
Journal of Clinical Microbiology logoLink to Journal of Clinical Microbiology
. 1985 Dec;22(6):951–954. doi: 10.1128/jcm.22.6.951-954.1985

Large-scale clinical comparison of the lysis-centrifugation and radiometric systems for blood culture.

P Brannon, T E Kiehn
PMCID: PMC271857  PMID: 3905850

Abstract

The Isolator 10 lysis-centrifugation blood culture system (E. I. du Pont de Nemours & Co., Inc., Wilmington, Del.) was compared with the BACTEC radiometric method (Johnston Laboratories, Inc., Towson, Md.) with 6B and 7D broth media for the recovery of bacteria and yeasts. From 11,000 blood cultures, 1,174 clinically significant organisms were isolated. The Isolator system recovered significantly more total organisms, members of the family Enterobacteriaceae, Staphylococcus spp., and yeasts. The BACTEC system recovered significantly more Pseudomonas spp., Streptococcus spp., and anaerobes. Of the Isolator colony counts, 87% measured less than 11 CFU/ml of blood. Organisms, on an average, were detected the same day from each of the two culture systems. Only 13 of the 975 BACTEC isolates (0.01%) were recovered by subculture of growth-index-negative bottles, and 12 of the 13 were detected in another broth blood culture taken within 24 h. Contaminants were recovered from 4.8% of the Isolator 10 and 2.3% of the BACTEC cultures.

Full text

PDF
954

Selected References

These references are in PubMed. This may not be the complete list of references from this article.

  1. Bille J., Stockman L., Roberts G. D., Horstmeier C. D., Ilstrup D. M. Evaluation of a lysis-centrifugation system for recovery of yeasts and filamentous fungi from blood. J Clin Microbiol. 1983 Sep;18(3):469–471. doi: 10.1128/jcm.18.3.469-471.1983. [DOI] [PMC free article] [PubMed] [Google Scholar]
  2. Dorn G. L., Land G. A., Wilson G. E. Improved blood culture technique based on centrifugation: clinical evaluation. J Clin Microbiol. 1979 Mar;9(3):391–396. doi: 10.1128/jcm.9.3.391-396.1979. [DOI] [PMC free article] [PubMed] [Google Scholar]
  3. Gill V. J., Zierdt C. H., Wu T. C., Stock F., Pizzo P. A., MacLowry J. D. Comparison of lysis-centrifugation with lysis-filtration and a conventional unvented bottle for blood cultures. J Clin Microbiol. 1984 Nov;20(5):927–932. doi: 10.1128/jcm.20.5.927-932.1984. [DOI] [PMC free article] [PubMed] [Google Scholar]
  4. Henry N. K., McLimans C. A., Wright A. J., Thompson R. L., Wilson W. R., Washington J. A., 2nd Microbiological and clinical evaluation of the isolator lysis-centrifugation blood culture tube. J Clin Microbiol. 1983 May;17(5):864–869. doi: 10.1128/jcm.17.5.864-869.1983. [DOI] [PMC free article] [PubMed] [Google Scholar]
  5. Kellogg J. A., Manzella J. P., McConville J. H. Clinical laboratory comparison of the 10-ml isolator blood culture system with BACTEC radiometric blood culture media. J Clin Microbiol. 1984 Oct;20(4):618–623. doi: 10.1128/jcm.20.4.618-623.1984. [DOI] [PMC free article] [PubMed] [Google Scholar]
  6. Kelly M. T., Buck G. E., Fojtasek M. F. Evaluation of a lysis-centrifugation and biphasic bottle blood culture system during routine use. J Clin Microbiol. 1983 Sep;18(3):554–557. doi: 10.1128/jcm.18.3.554-557.1983. [DOI] [PMC free article] [PubMed] [Google Scholar]
  7. Kelly M. T., Fojtasek M. F., Abbott T. M., Hale D. C., Dizikes J. R., Boshard R., Buck G. E., Martin W. J., Matsen J. M. Clinical evaluation of a lysis-centrifugation technique for the detection of septicemia. JAMA. 1983 Oct 28;250(16):2185–2188. [PubMed] [Google Scholar]
  8. Kiehn T. E., Edwards F. F., Brannon P., Tsang A. Y., Maio M., Gold J. W., Whimbey E., Wong B., McClatchy J. K., Armstrong D. Infections caused by Mycobacterium avium complex in immunocompromised patients: diagnosis by blood culture and fecal examination, antimicrobial susceptibility tests, and morphological and seroagglutination characteristics. J Clin Microbiol. 1985 Feb;21(2):168–173. doi: 10.1128/jcm.21.2.168-173.1985. [DOI] [PMC free article] [PubMed] [Google Scholar]
  9. Kiehn T. E., Wong B., Edwards F. F., Armstrong D. Comparative recovery of bacteria and yeasts from lysis-centrifugation and a conventional blood culture system. J Clin Microbiol. 1983 Aug;18(2):300–304. doi: 10.1128/jcm.18.2.300-304.1983. [DOI] [PMC free article] [PubMed] [Google Scholar]
  10. Kiehn T. E., Wong B., Edwards F. F., Armstrong D. Routine aerobic terminal subculturing of blood cultures in a cancer hospital. J Clin Microbiol. 1983 Oct;18(4):885–889. doi: 10.1128/jcm.18.4.885-889.1983. [DOI] [PMC free article] [PubMed] [Google Scholar]
  11. McLaughlin J. C., Hamilton P., Scholes J. V., Bartlett R. C. Clinical laboratory comparison of lysis-centrifugation and BACTEC radiometric blood culture techniques. J Clin Microbiol. 1983 Nov;18(5):1027–1031. doi: 10.1128/jcm.18.5.1027-1031.1983. [DOI] [PMC free article] [PubMed] [Google Scholar]
  12. Whimbey E., Wong B., Kiehn T. E., Armstrong D. Clinical correlations of serial quantitative blood cultures determined by lysis-centrifugation in patients with persistent septicemia. J Clin Microbiol. 1984 Jun;19(6):766–771. doi: 10.1128/jcm.19.6.766-771.1984. [DOI] [PMC free article] [PubMed] [Google Scholar]
  13. Wong B., Edwards F. F., Kiehn T. E., Whimbey E., Donnelly H., Bernard E. M., Gold J. W., Armstrong D. Continuous high-grade mycobacterium avium-intracellulare bacteremia in patients with the acquired immune deficiency syndrome. Am J Med. 1985 Jan;78(1):35–40. doi: 10.1016/0002-9343(85)90458-9. [DOI] [PubMed] [Google Scholar]

Articles from Journal of Clinical Microbiology are provided here courtesy of American Society for Microbiology (ASM)

RESOURCES