Skip to main content
Journal of Clinical Microbiology logoLink to Journal of Clinical Microbiology
. 1982 Dec;16(6):1048–1051. doi: 10.1128/jcm.16.6.1048-1051.1982

Direct identification of Staphylococcus aureus in blood culture fluid with a commercial latex agglutination test.

G V Doern, L I Robbie
PMCID: PMC272537  PMID: 6761357

Abstract

A commercial latex agglutination slide test (SeroSTAT Staph, Scott Laboratories, Inc., Fiskeville, R.I.) accurately identified Staphylococcus aureus when applied directly to blood culture fluid containing staphylococci. This latex agglutination test exhibited 100% accuracy when 30 seeded aerobic and anaerobic radiometric blood cultures (15 strains of S. aureus, 15 strains of other staphylococcal species) were tested blindly. In 36 actual clinical specimens yielding 16 isolates of S. aureus and 20 isolates of Staphylococcus epidermidis, 94.4% accuracy was achieved. The latex agglutination test provided positive test results before objective criteria of blood culture positivity such as radiometric growth indices and Gram stains became positive.

Full text

PDF
1049

Selected References

These references are in PubMed. This may not be the complete list of references from this article.

  1. Blazevic D. J., Stemper J. E., Matsen J. M. Effect of aerobic and anaerobic atmospheres on isolation of organisms from blood cultures. J Clin Microbiol. 1975 Feb;1(2):154–156. doi: 10.1128/jcm.1.2.154-156.1975. [DOI] [PMC free article] [PubMed] [Google Scholar]
  2. Doern G. V. Evaluation of a commercial latex agglutination test for identification of Staphylococcus aureus. J Clin Microbiol. 1982 Mar;15(3):416–418. doi: 10.1128/jcm.15.3.416-418.1982. [DOI] [PMC free article] [PubMed] [Google Scholar]
  3. Essers L., Radebold K. Rapid and reliable identification of Staphylococcus aureus by a latex agglutination test. J Clin Microbiol. 1980 Nov;12(5):641–643. doi: 10.1128/jcm.12.5.641-643.1980. [DOI] [PMC free article] [PubMed] [Google Scholar]
  4. Harkness J. L., Hall M., Ilstrup D. M., Washington J. A., 2nd Effects of atmosphere of incubation and of routine subcultures on detection of bacteremia in vacuum blood culture bottles. J Clin Microbiol. 1975 Oct;2(4):296–299. doi: 10.1128/jcm.2.4.296-299.1975. [DOI] [PMC free article] [PubMed] [Google Scholar]
  5. Myrick B. A., Ellner P. D. Evaluation of the latex slide agglutination test for identification of Staphylococcus aureus. J Clin Microbiol. 1982 Feb;15(2):275–277. doi: 10.1128/jcm.15.2.275-277.1982. [DOI] [PMC free article] [PubMed] [Google Scholar]
  6. Thiemke W. A., Wicher K. Laboratory experience with a radiometric method for detecting bacteremia. J Clin Microbiol. 1975 Mar;1(3):302–308. doi: 10.1128/jcm.1.3.302-308.1975. [DOI] [PMC free article] [PubMed] [Google Scholar]
  7. Washington J. A., 2nd, Hall M. M., Warren E. Evaluation of blood culture media supplemented with sucrose or with cysteine. J Clin Microbiol. 1975 Jan;1(1):79–81. doi: 10.1128/jcm.1.1.79-81.1975. [DOI] [PMC free article] [PubMed] [Google Scholar]

Articles from Journal of Clinical Microbiology are provided here courtesy of American Society for Microbiology (ASM)