Toluidine red unheated serum test, a nontreponemal test for syphilis.

D E Pettit, S A Larsen, P S Harbec, J C Feeley, C E Parham, D D Cruce, E A Hambie, M W Perryman
PMCID: PMC272857  PMID: 6417160

Abstract

We have shown that a modification of the color-coded antigen developed by Kasatiya and Lambert (Appl. Microbiol. 28:317-318, 1974) can be used as a substitute for other nontreponemal antigens used in screening tests for syphilis. The antigen is based on the Venereal Disease Research Laboratory antigen, with EDTA, choline chloride, and toluidine red toner added. Performance of the toluidine red unheated serum test (TRUST) is identical to that of the rapid plasma reagin 18-mm circle card test (U.S. Department of Health, Education, and Welfare, Public Health Service Publication no. 411). In a series of preliminary evaluations, the TRUST antigen was found to be stable over a period of 6 months at 4 degrees C. In a comparison of TRUST with the rapid plasma reagin card test, the qualitative agreement was 100%, whereas agreement between these two tests and the Venereal Disease Research Laboratory slide test was 99.7%. The quantitative agreement +/- 1 twofold dilution between TRUST and the rapid plasma reagin card test was 100%; between TRUST and the Venereal Disease Research Laboratory slide test it was 75.0%; and between the rapid plasma reagin card and Venereal Disease Research Laboratory slide tests it was 60.0%.

Full text

PDF
1145

Selected References

These references are in PubMed. This may not be the complete list of references from this article.

  1. Kasatiya S. S., Lambert N. G. Color-coded antigen for the automated reagin test for syphilis. Appl Microbiol. 1974 Aug;28(2):317–318. doi: 10.1128/am.28.2.317-318.1974. [DOI] [PMC free article] [PubMed] [Google Scholar]
  2. Lambert N. G., Ste-Marie A. R. A more complete evaluation of the color-coded antigen for the automated reagin test. J Clin Microbiol. 1975 Apr;1(4):390–390. doi: 10.1128/jcm.1.4.390-390.1975. [DOI] [PMC free article] [PubMed] [Google Scholar]
  3. Larsen S. A., Pettit D. E., Perryman M. W., Hambie E. A., Mullally R., Whittington W. EDTA-treated plasma in the rapid plasma reagin card test and the toluidine red unheated serum test for serodiagnosis of syphilis. J Clin Microbiol. 1983 Feb;17(2):341–345. doi: 10.1128/jcm.17.2.341-345.1983. [DOI] [PMC free article] [PubMed] [Google Scholar]
  4. PORTNOY J., BREWER J. H., HARRIS A. Rapid plasma reagin card test for syphilis and other treponematoses. Public Health Rep. 1962 Aug;77:645–652. [PMC free article] [PubMed] [Google Scholar]