Skip to main content
Journal of Clinical Microbiology logoLink to Journal of Clinical Microbiology
. 1976 Mar;3(3):281–286. doi: 10.1128/jcm.3.3.281-286.1976

Clinical comparison of aerobic, hypertonic, and anaerobic culture media for the radiometric detection of bacteremia.

R M Coleman, W W Laslie, D W Lambe Jr
PMCID: PMC274284  PMID: 1270592

Abstract

The BACTEC 225 was used to test 5,811 routine blood cultures over a 20-month period. Aerobic, anaerobic, and hypertonic media were employed. The BACTEC 225 detected 511 positive cultures; 407 of these were considered significant organisms, and 104 were presumed contaminants. Of the significant positive cultures, 15% were detected within the first 12 h of incubation, 52% within 24 h, 82% within 48 h and 92% within 72 h. Aerobic, anaerobic, and hypertonic media are recommended for each venipuncture since 56 cultures were isolated from the aerobic medium only, 110 from the anaerobic medium only, and 94 from the hypertonic medium only. There were 16 patients who had multiple venipunctures from which organisms were repeatedly isolated from only one medium: two from the aerobic medium, four from the anaerobic medium, and ten from the hypertonic medium only. Detection times were not significantly different for the aerobic and hypertonic media. However, there were five patients with multiple venipunctures in which growth was detected radiometrically at least 48 h earlier in the hypertonic than in the aerobic medium. False-positive growth index readings were noted in 1,085 (19%) of the aerobic vial, 11 (0.19%) of the anaerobic vials, microorganisms were isolated from at least one of the companion vials. Using 5% co2 to flush the aerobic vials. With some false-positive aerobic and hypertonic vials decreased the number of false positives to about 6% of the total.

Full text

PDF
285

Selected References

These references are in PubMed. This may not be the complete list of references from this article.

  1. Bannatyne R. M., Harnett N. Radiometric detection of bacteremia in neonates. Appl Microbiol. 1974 Jun;27(6):1067–1069. doi: 10.1128/am.27.6.1067-1069.1974. [DOI] [PMC free article] [PubMed] [Google Scholar]
  2. Brooks K., Sodeman T. Rapid detection of bacteremia by a radiometric system. A clinical evaluation. Am J Clin Pathol. 1974 Jun;61(6):859–866. doi: 10.1093/ajcp/61.6.859. [DOI] [PubMed] [Google Scholar]
  3. Caslow M., Ellner P. D., Kiehn T. E. Comparison of the BACTEC system with blind subculture for the detection of bacteremia. Appl Microbiol. 1974 Sep;28(3):435–438. doi: 10.1128/am.28.3.435-438.1974. [DOI] [PMC free article] [PubMed] [Google Scholar]
  4. DeBlanc H. J., Jr, DeLand F., Wagner H. N., Jr Automated radiometric detection of bacteria in 2,967 blood cultures. Appl Microbiol. 1971 Nov;22(5):846–849. doi: 10.1128/am.22.5.846-849.1971. [DOI] [PMC free article] [PubMed] [Google Scholar]
  5. Johnson W. D., Kaye D. Serious infections caused by diphtheroids. Ann N Y Acad Sci. 1970 Oct 30;174(2):568–576. doi: 10.1111/j.1749-6632.1970.tb45582.x. [DOI] [PubMed] [Google Scholar]
  6. Renner E. D., Gatheridge L. A., Washington J. A., 2nd Evaluation of radiometric system for detecting bacteremia. Appl Microbiol. 1973 Sep;26(3):368–372. doi: 10.1128/am.26.3.368-372.1973. [DOI] [PMC free article] [PubMed] [Google Scholar]
  7. Rosner R. Comparison of a blood culture system containing liquoid and sucrose with systems containing either reagent alone. Appl Microbiol. 1970 Feb;19(2):281–282. doi: 10.1128/am.19.2.281-282.1970. [DOI] [PMC free article] [PubMed] [Google Scholar]
  8. Rosner R. Comparison of macroscopic, microscopic, and radiometric examinations of clinical blood cultures in hypertonic media. Appl Microbiol. 1974 Oct;28(4):644–646. doi: 10.1128/am.28.4.644-646.1974. [DOI] [PMC free article] [PubMed] [Google Scholar]
  9. Sullivan N. M., Sutter V. L., Carter W. T., Attebery H. R., Finegold S. M. Bacteremia after genitourinary tract manipulation: bacteriological aspects and evaluation of various blood culture systems. Appl Microbiol. 1972 Jun;23(6):1101–1106. doi: 10.1128/am.23.6.1101-1106.1972. [DOI] [PMC free article] [PubMed] [Google Scholar]
  10. Thiemke W. A., Wicher K. Laboratory experience with a radiometric method for detecting bacteremia. J Clin Microbiol. 1975 Mar;1(3):302–308. doi: 10.1128/jcm.1.3.302-308.1975. [DOI] [PMC free article] [PubMed] [Google Scholar]
  11. Washington J. A., 2nd Comparison of two commercially available media for detection of bacteremia. Appl Microbiol. 1971 Oct;22(4):604–607. doi: 10.1128/am.22.4.604-607.1971. [DOI] [PMC free article] [PubMed] [Google Scholar]

Articles from Journal of Clinical Microbiology are provided here courtesy of American Society for Microbiology (ASM)

RESOURCES