Abstract
A solid-phase radioimmunoassay for the rapid determination of human immunoglobulin M (IgM) rheumatoid factor (RF) has been developed. Preparation of the solid phase for the assay involved the formation of complexes between respiratory syncytial virus-specific human IgG antibodies and virus antigen on the surface of polystyrene balls. Binding of serum RF to IgG in the immune complex was subsequently detected by 125I-labeled mu-chain-specific antibodies to human IgM. The amount of radioactive indicator antibody bound was converted to units of RF by comparison to the standard curve for an RF reference-serum pool. This assay should prove useful in studies of the physiological role of RF, since it can effectively measure low levels of circulating RF.
Full text
PDF![134](https://cdn.ncbi.nlm.nih.gov/pmc/blobs/05f1/275170/abbdf8c057a9/jcm00193-0035.png)
![135](https://cdn.ncbi.nlm.nih.gov/pmc/blobs/05f1/275170/216207f21c93/jcm00193-0036.png)
![136](https://cdn.ncbi.nlm.nih.gov/pmc/blobs/05f1/275170/f59720b57533/jcm00193-0037.png)
![137](https://cdn.ncbi.nlm.nih.gov/pmc/blobs/05f1/275170/027bf6303a6f/jcm00193-0038.png)
![138](https://cdn.ncbi.nlm.nih.gov/pmc/blobs/05f1/275170/58d5a01233c3/jcm00193-0039.png)
![139](https://cdn.ncbi.nlm.nih.gov/pmc/blobs/05f1/275170/4c299f8c23da/jcm00193-0040.png)
![140](https://cdn.ncbi.nlm.nih.gov/pmc/blobs/05f1/275170/b0bd67d33058/jcm00193-0041.png)
![141](https://cdn.ncbi.nlm.nih.gov/pmc/blobs/05f1/275170/c085c7bd46df/jcm00193-0042.png)
Selected References
These references are in PubMed. This may not be the complete list of references from this article.
- 1958 REVISION of diagnostic criteria for rheumatoid arthritis. Arthritis Rheum. 1959 Feb;2(1):16–20. doi: 10.1002/1529-0131(195902)2:1<16::aid-art1780020104>3.0.co;2-9. [DOI] [PubMed] [Google Scholar]
- AHO K. The problem of the antibody nature of the rheumatoid factor. Ann Med Exp Biol Fenn. 1961;39(Suppl 7):1–60. [PubMed] [Google Scholar]
- Arstila P., Vuorimaa T., Kalimo K., Halonen P., Viljanen M., Granfors K., Toivanen P. A solid-phase radioimmunoassay for IgG and IgM antibodies against measles virus. J Gen Virol. 1977 Jan;34(1):167–176. doi: 10.1099/0022-1317-34-1-167. [DOI] [PubMed] [Google Scholar]
- Cambiaso C. L., Goffinet A., Vaerman J. P., Heremans J. F. Glutaraldehyde-activated aminohexyl- derivative of Sepharose 4B as a new verstile immunoabsorbent. Immunochemistry. 1975 Apr;12(4):273–278. doi: 10.1016/0019-2791(75)90175-5. [DOI] [PubMed] [Google Scholar]
- Carson D. A., Lawrance S., Catalano M. A., Vaughan J. H., Abraham G. Radioimmunoassay of IgG and IgM rheumatoid factors reacting with human IgG. J Immunol. 1977 Jul;119(1):295–300. [PubMed] [Google Scholar]
- Focan-Henrard D., Franchimont P., Bertrand E. Radioimmunoassay of the rheumatoid factors. Rheumatology. 1975;6:140–150. [PubMed] [Google Scholar]
- Franchimont P., Suteanu S. Radioimmunoassay of rheumatoid factor. Arthritis Rheum. 1969 Oct;12(5):483–490. doi: 10.1002/art.1780120504. [DOI] [PubMed] [Google Scholar]
- HARBOE M. Relation between Gm types and hemagglutinating substances in rheumatoid sera. Acta Pathol Microbiol Scand. 1960;50:89–105. doi: 10.1111/j.1699-0463.1960.tb01175.x. [DOI] [PubMed] [Google Scholar]
- HUNTER W. M., GREENWOOD F. C. Preparation of iodine-131 labelled human growth hormone of high specific activity. Nature. 1962 May 5;194:495–496. doi: 10.1038/194495a0. [DOI] [PubMed] [Google Scholar]
- Hay F. C., Nineham L. J., Roitt I. M. Routine assay for detection of IgG and IgM antiglobulins in seronegative and seropositive rheumatoid arthritis. Br Med J. 1975 Jul 26;3(5977):203–204. doi: 10.1136/bmj.3.5977.203. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Johnson P. M., Faulk W. P. Rheumatoid factor: its nature, specificity, and production in rheumatoid arthritis. Clin Immunol Immunopathol. 1976 Nov;6(3):414–430. doi: 10.1016/0090-1229(76)90094-5. [DOI] [PubMed] [Google Scholar]
- Kalimo K. O., Meurman O. H., Halonen P. E., Ziola B. R., Viljanen M. K., Granfors K., Toivanen P. Solid-phase radioimmunoassay of rubella virus immunoglobulin G and immunoglobulin M antibodies. J Clin Microbiol. 1976 Aug;4(2):117–123. doi: 10.1128/jcm.4.2.117-123.1976. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Kalimo K. O., Ziola B. R., Viljanen M. K., Granfors K., Toivanen P. Solid-phase radioimmunoassay of herpes simplex virus IgG and IgM antibodies. J Immunol Methods. 1977;14(2):183–195. doi: 10.1016/0022-1759(77)90008-4. [DOI] [PubMed] [Google Scholar]
- Knez V., Reimer C. B. An indirect solid-phase microradioimmunoassay for human IgM-anti-IgG (rheumatoid factor). J Immunol Methods. 1977;18(1-2):105–121. doi: 10.1016/0022-1759(77)90162-4. [DOI] [PubMed] [Google Scholar]
- Kochwa S., Brownell M., Rosenfield R. E., Wasserman L. R. Adsorption of proteins by polystyrene particles. I. Molecular unfolding and acquired immunogenicity of IgG. J Immunol. 1967 Nov;99(5):981–986. [PubMed] [Google Scholar]
- Krohn K., Sherman L., Welch M. Studies of radioiodinated fibrinogen. I. Physicochemical properties of the ICl, chloramine-T, and electrolytic reaction products. Biochim Biophys Acta. 1972 Dec 28;285(2):404–413. doi: 10.1016/0005-2795(72)90327-3. [DOI] [PubMed] [Google Scholar]
- LOWRY O. H., ROSEBROUGH N. J., FARR A. L., RANDALL R. J. Protein measurement with the Folin phenol reagent. J Biol Chem. 1951 Nov;193(1):265–275. [PubMed] [Google Scholar]
- Levine S., Hamilton R. Kinetics of the respiratory syncytial virus growth cycle in HeLa cells. Arch Gesamte Virusforsch. 1969;28(2):122–132. doi: 10.1007/BF01249378. [DOI] [PubMed] [Google Scholar]
- Meurman O. H., Viljanen M. K., Granfors K. Solid-phase radioimmunoassay of rubella virus immunoglobulin M antibodies: comparison with sucrose density gradient centrifugation test. J Clin Microbiol. 1977 Mar;5(3):257–262. doi: 10.1128/jcm.5.3.257-262.1977. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Nineham L. J., Hay F. C., Roitt I. M. Laboratory diagnosis of rheumatoid arthritis: a solid phase radioassay for IgG and IgM antiglobulins. J Clin Pathol. 1976 Dec;29(12):1121–1126. doi: 10.1136/jcp.29.12.1121. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Normansell D. E. Anti- -globulins in rheumatoid arthritis sera. 3. The reactivity of anti- -globulin rheumatoid factors with heterologous G-globulin. Immunochemistry. 1972 Jul;9(7):725–736. doi: 10.1016/0019-2791(72)90016-x. [DOI] [PubMed] [Google Scholar]
- SIEVERS K. THE RHEUMATOID FACTOR IN DEFINITE RHEUMATOID ARTHRITIS. AN ANALYSIS OF 1279 ADULT PATIENTS, WITH A FOLLOW-UP STUDY. Acta Rheumatol Scand Suppl. 1965:SUPPL 9–121. doi: 10.3109/rhe1.1965.10.suppl-9.01. [DOI] [PubMed] [Google Scholar]
- Shirodaria P. V., Fraser K. B., Stanford F. Secondary fluorescent staining of virus antigens by rheumatoid factor and fluorescein-conjugated anti-IgM. Ann Rheum Dis. 1973 Jan;32(1):53–57. doi: 10.1136/ard.32.1.53. [DOI] [PMC free article] [PubMed] [Google Scholar]
- WALLER M. V., VAUGHAN J. H. Use of anti-Rh sera for demonstrating agglutination activating factor in rheumatoid arthritis. Proc Soc Exp Biol Med. 1956 May;92(1):198–200. doi: 10.3181/00379727-92-22426. [DOI] [PubMed] [Google Scholar]
- Wunner W. H., Pringle C. R. Respiratory syncytial virus proteins. Virology. 1976 Aug;73(1):228–243. doi: 10.1016/0042-6822(76)90077-5. [DOI] [PubMed] [Google Scholar]
- Ziola B. R., Matikainen M. T., Salmi A. Polystyrene balls as the solid-phase of a double-antibody radioimmunoassay for human serum albumin. J Immunol Methods. 1977;17(3-4):309–317. doi: 10.1016/0022-1759(77)90113-2. [DOI] [PubMed] [Google Scholar]