Abstract
An anaerobic transport system (ATS) which provides for catalytic removal of oxygen was evaluated by using in vitro-prepared polymicrobial mixtures of logphase bacteria and clinical specimens. Inoculated swabs were stored at room temperature in (i) aerobic, (ii) anaerobic glove box, and (iii) ATS environments, and bacteria were quantitated after 2, 24, 48, and 72 h. Bacteria in a three-part mixture of Bacteroides fragilis, Peptostreptococcus anaerobius, and Escherichia coli and in a five-part mixture of B. fragilis, P. anaerobius, Fusobacterium nucleatum, Staphylococcus epidermidis, and Pseudomonas aeruginosa survived 72 h of storage in the ATS and anaerobic glove box environments, but the anaerobic species were inactivated in the aerobic storage except for B. fragilis in pure culture or in the three-part mixture. Changes in relative proportions among the species in a mixture were least in the ATS and anaerobic glove box environments and greatest during the aerobic storage, particularly in the five-part mixture. Bacteria present in pure or mixed culture in clinical specimens generally survived 72 h of storage in the ATS. These data indicate that changes in relative proportions occur with prolonged storage even under anaerobic conditions, but that the ATS would be most effective for preserving anaerobic bacteria and preventing drastic concentration changes and overgrowth of facultative and aerobic bacteria.
Full text
PDFImages in this article
Selected References
These references are in PubMed. This may not be the complete list of references from this article.
- Barry A. L., Fay G. D., Sauer R. L. Efficiency of a transport medium for the recovery of aerobic and anaerobic bacteria from applicator swabs. Appl Microbiol. 1972 Jul;24(1):31–33. doi: 10.1128/am.24.1.31-33.1972. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Bartlett J. G., Sullivan-Sigler N., Louie T. J., Gorbach S. L. Anaerobes survive in clinical specimens despite delayed processing. J Clin Microbiol. 1976 Feb;3(2):133–136. doi: 10.1128/jcm.3.2.133-136.1976. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Chow A. W., Cunningham P. J., Guze L. B. Survival of anaerobic and aerobic bacteria in a nonsupportive gassed transport system. J Clin Microbiol. 1976 Feb;3(2):128–132. doi: 10.1128/jcm.3.2.128-132.1976. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Ederer G. M., Christian D. L. Evaluation of bacteriological transport systems. Am J Med Technol. 1975 Aug;41(8):299–306. [PubMed] [Google Scholar]
- Hagen J. C., Wood W. S., Hashimoto T. Effect of chilling on the survival of Bacteroides fragilis. J Clin Microbiol. 1976 Nov;4(5):432–436. doi: 10.1128/jcm.4.5.432-436.1976. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Hallander H. O., Flodström A., Holmberg K. Influence of the collection and transport of specimens on the recovery of bacteria from peritonsillar abscesses. J Clin Microbiol. 1975 Dec;2(6):504–509. doi: 10.1128/jcm.2.6.504-509.1975. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Jefferson H., Dalton H. P., Escobar M. R., Allison M. J. Transportation delay and the microbiological quality of clinical specimens. Am J Clin Pathol. 1975 Nov;64(5):689–693. doi: 10.1093/ajcp/64.5.689. [DOI] [PubMed] [Google Scholar]
- Ledger W. J., Gee C. L., Pollin R., Nakamura R. M., Lewis W. P. The use of pr-reduced media and a portable jar for the collection of anaerobic organisms for clinical sites of infection. Am J Obstet Gynecol. 1976 Jul 1;125(5):677–681. doi: 10.1016/0002-9378(76)90793-6. [DOI] [PubMed] [Google Scholar]
- Syed S. A., Loesche W. J. Survival of human dental plaque flora in various transport media. Appl Microbiol. 1972 Oct;24(4):638–644. doi: 10.1128/am.24.4.638-644.1972. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Tally F. P., Stewart P. R., Sutter V. L., Rosenblatt J. E. Oxygen tolerance of fresh clinical anaerobic bacteria. J Clin Microbiol. 1975 Feb;1(2):161–164. doi: 10.1128/jcm.1.2.161-164.1975. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Wilkins T. D., Jimenez-Ulate F. Anaerobic specimen transport device. J Clin Microbiol. 1975 Nov;2(5):441–447. doi: 10.1128/jcm.2.5.441-447.1975. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Yrios J. W., Balish E., Helstad A., Field C., Inhorn S. Survival of anaerobic and aerobic bacteria on cotton swabs in three transport systems. J Clin Microbiol. 1975 Feb;1(2):196–200. doi: 10.1128/jcm.1.2.196-200.1975. [DOI] [PMC free article] [PubMed] [Google Scholar]