Skip to main content
The Journal of Clinical Investigation logoLink to The Journal of Clinical Investigation
. 1967 Sep;46(9):1402–1412. doi: 10.1172/JCI105632

Regional Myocardial Blood Flow*

Jay M Sullivan 1,, Warren J Taylor 1,§, William C Elliott 1,ǁ, Richard Gorlin 1,
PMCID: PMC292886  PMID: 6036537

Abstract

A method is described which measures the local effectiveness of the myocardial circulation, expressed as a clearance constant. Uniform clearance constants have been demonstrated in the normal canine and human myocardium. A distinct difference in clearance constants has been demonstrated between the normal canine myocardium and areas of naturally occurring disease. Heterogeneous clearance constants have been found in a majority of human subjects with coronary artery disease—the lowest rates being noted in areas of fibrous aneurysm.

Full text

PDF
1410

Selected References

These references are in PubMed. This may not be the complete list of references from this article.

  1. Brener B. J., Warren R. Internal-mammary implantation operations for relief of myocardial ischemia. N Engl J Med. 1965 Aug 26;273(9):479–489. doi: 10.1056/NEJM196508262730905. [DOI] [PubMed] [Google Scholar]
  2. CONNOLLY J. E., BACANER M. B., BRUNS D. L., LOWENSTEIN J. M., STORLI E. The effect of venoarterial bypass on coronary blood flow. Arch Surg. 1960 Jul;81:58–60. doi: 10.1001/archsurg.1960.01300010060009. [DOI] [PubMed] [Google Scholar]
  3. CULLEN M. L., REESE H. L. Myocardial circulatory changes measured by clearance of Na24; effect of common duct distension on myocardial circulation. J Appl Physiol. 1952 Dec;5(6):281–284. doi: 10.1152/jappl.1952.5.6.281. [DOI] [PubMed] [Google Scholar]
  4. HERD J. A., HOLLENBERG M., THORBURN G. D., KOPALD H. H., BARGER A. C. Myocardial blood flow determined with krypton 85 in unanesthetized dogs. Am J Physiol. 1962 Jul;203:122–124. doi: 10.1152/ajplegacy.1962.203.1.122. [DOI] [PubMed] [Google Scholar]
  5. HOLLANDER W., MADOFF I. M., CHOBANIAN A. V. Local myocardial blood flow as indicated by the disappearance of Nal-131 from the heart muscle: studies at rest, during exercise, and following nitrite administration. J Pharmacol Exp Ther. 1963 Jan;139:53–59. [PubMed] [Google Scholar]
  6. KIRK E. S., HONIG C. R. NONUNIFORM DISTRIBUTION OF BLOOD FLOW AND GRADIENTS OF OXYGEN TENSION WITHIN THE HEART. Am J Physiol. 1964 Sep;207:661–668. doi: 10.1152/ajplegacy.1964.207.3.661. [DOI] [PubMed] [Google Scholar]
  7. LASSEN N. A., LINDBJERG I. F., DAHN I. VALIDITY OF THE XENON-133-METHOD FOR MEASUREMENT OF MUSCLE BLOOD FLOW EVALUATED BY SIMULTANEOUS VENOUS OCCLUSION PLETHYSMOGRAPHY: OBSERVATIONS IN THE CALF OF NORMAL MAN AND IN PATIENTS WITH OCCLUSIVE VASCULAR DISEASE. Circ Res. 1965 Mar;16:287–293. doi: 10.1161/01.res.16.3.287. [DOI] [PubMed] [Google Scholar]
  8. LASSEN N. A. MUSCLE BLOOD FLOW IN NORMAL MAN AND IN PATIENTS WITH INTERMITTENT CLAUDICATION EVALUATED BY SIMULTANEOUS XE-133 AND NA24 CLEARANCES. J Clin Invest. 1964 Sep;43:1805–1812. doi: 10.1172/JCI105054. [DOI] [PMC free article] [PubMed] [Google Scholar]
  9. RENKIN E. M. Transport of potassium-42 from blood to tissue in isolated mammalian skeletal muscles. Am J Physiol. 1959 Dec;197:1205–1210. doi: 10.1152/ajplegacy.1959.197.6.1205. [DOI] [PubMed] [Google Scholar]
  10. ROSS R. S., UEDA K., LICHTLEN P. R., REES J. R. MEASUREMENT OF MYOCARDIAL BLOOD FLOW IN ANIMALS AND MAN BY SELECTIVE INJECTION OF RADIOACTIVE INERT GAS INTO THE CORONARY ARTERIES. Circ Res. 1964 Jul;15:28–41. doi: 10.1161/01.res.15.1.28. [DOI] [PubMed] [Google Scholar]
  11. SALISBURY P. F., CROSS C. E., OBLATH R. W., RIEBEN P. A. Local circulation in heart muscle studied with Na24 clearance method. J Appl Physiol. 1962 May;17:475–478. doi: 10.1152/jappl.1962.17.3.475. [DOI] [PubMed] [Google Scholar]

Articles from Journal of Clinical Investigation are provided here courtesy of American Society for Clinical Investigation

RESOURCES