Abstract
The multiply charged ions produced by electrospray ionization of peptides of molecular masses up to 29 kDa have been successfully introduced into a Fourier transform mass spectrometer of unique capabilities for tandem mass spectrometry, large ion dissociation, and resolution. Electrospray ionization places an unusually high number of charges on a peptide yielding mass/charge (m/z) values of 600-1500; in this range at normal operating pressures (approximately 10(-9) torr; 1 torr = 133.3 Pa) Fourier-transform mass spectrometry resolving power is greater than 100,000. Although only 10(-7) torr pressure has been obtained with the initial interface, the resulting resolving power of 5000 makes possible the resolution of isotopic peaks of multiply charged ions. Mass measuring accuracies of a few daltons for molecular masses up to 17 kDa have also been achieved.
Full text
PDF![9075](https://cdn.ncbi.nlm.nih.gov/pmc/blobs/35e7/298436/d0e30583d227/pnas00290-0033.png)
![9076](https://cdn.ncbi.nlm.nih.gov/pmc/blobs/35e7/298436/47e484d7fa3f/pnas00290-0034.png)
![9077](https://cdn.ncbi.nlm.nih.gov/pmc/blobs/35e7/298436/4647176b4a3d/pnas00290-0035.png)
![9078](https://cdn.ncbi.nlm.nih.gov/pmc/blobs/35e7/298436/6cb71f7044bc/pnas00290-0036.png)
Selected References
These references are in PubMed. This may not be the complete list of references from this article.
- Amster I. J., McLafferty F. W., Castro M. E., Russell D. H., Cody R. B., Jr, Ghaderi S. Detection of mass 16 241 ions by Fourier-transform mass spectrometry. Anal Chem. 1986 Feb;58(2):483–485. doi: 10.1021/ac00293a049. [DOI] [PubMed] [Google Scholar]
- Chen L., Wang T. C., Ricca T. L., Marshall A. G. Phase-modulated stored waveform inverse Fourier transform excitation for trapped ion mass spectrometry. Anal Chem. 1987 Feb 1;59(3):449–454. doi: 10.1021/ac00130a016. [DOI] [PubMed] [Google Scholar]
- Cody R. B., Jr, Amster I. J., McLafferty F. W. Peptide mixture sequencing by tandem Fourier-transform mass spectrometry. Proc Natl Acad Sci U S A. 1985 Oct;82(19):6367–6370. doi: 10.1073/pnas.82.19.6367. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Covey T. R., Bonner R. F., Shushan B. I., Henion J. The determination of protein, oligonucleotide and peptide molecular weights by ion-spray mass spectrometry. Rapid Commun Mass Spectrom. 1988 Nov;2(11):249–256. doi: 10.1002/rcm.1290021111. [DOI] [PubMed] [Google Scholar]
- Hunt D. F., Shabanowitz J., Yates J. R., 3rd, Zhu N. Z., Russell D. H., Castro M. E. Tandem quadrupole Fourier-transform mass spectrometry of oligopeptides and small proteins. Proc Natl Acad Sci U S A. 1987 Feb;84(3):620–623. doi: 10.1073/pnas.84.3.620. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Hunt D. F., Zhu N. Z., Shabanowitz J. Oligopeptide sequence analysis by collision-activated dissociation of multiply charged ions. Rapid Commun Mass Spectrom. 1989 Apr;3(4):122–124. doi: 10.1002/rcm.1290030408. [DOI] [PubMed] [Google Scholar]
- Loo J. A., Udseth H. R., Smith R. D. Peptide and protein analysis by electrospray ionization-mass spectrometry and capillary electrophoresis-mass spectrometry. Anal Biochem. 1989 Jun;179(2):404–412. doi: 10.1016/0003-2697(89)90153-x. [DOI] [PubMed] [Google Scholar]
- Wibf H. K., Irving P., McCamish M., Venkataraghavan R., McLafferty F. W. Mass spectrometric studies of peptides. V. Determination of amino acid sequences in peptide mixtures by mass spectrometry. J Am Chem Soc. 1973 May 16;95(10):3369–3375. doi: 10.1021/ja00791a048. [DOI] [PubMed] [Google Scholar]
- Williams R. E., Berry J. G. Evaluation of CGA 72662 as a topical spray and feed additive for controlling house flies breeding in chicken manure. Poult Sci. 1980 Oct;59(10):2207–2212. doi: 10.3382/ps.0592207. [DOI] [PubMed] [Google Scholar]