Abstract
13C and 15N chemical shift (CS) interaction is a sensitive probe of structure and dynamics in a wide variety of biological and inorganic systems, and in the recent years several magic angle spinning NMR approaches have emerged for residue-specific measurements of chemical shift anisotropy (CSA) tensors in uniformly and sparsely enriched proteins. All of the currently existing methods are applicable to slow and moderate magic angle spinning (MAS) regime, i.e., MAS frequencies below 20 kHz. With the advent of fast and ultrafast MAS probes capable of spinning frequencies of 40–100 kHz, and with the superior resolution and sensitivity attained at such high frequencies, development of CSA recoupling techniques working under such conditions is necessary. In this work, we present a family of R-symmetry based pulse sequences for recoupling of 13C/15N CSA interactions that work well in both natural abundance and isotopically enriched systems. We demonstrate that efficient recoupling of either first-rank (σ1) or second-rank (σ2) spatial components of CSA interaction is attained with appropriately chosen γ-encoded RNnv symmetry sequences. The advantage of these γ-encoded RNnv-symmetry based CSA (RNCSA) recoupling schemes is that they are suitable for CSA recoupling under a wide range of MAS frequencies, including fast MAS regime. Comprehensive analysis of the recoupling properties of these RNnv symmetry sequences reveals that the σ1-CSA recoupling symmetry sequences exhibit large scaling factors; however, the partial homonuclear dipolar Hamiltonian components are symmetry allowed, which makes this family of sequences suitable for CSA measurements in systems with weak homonuclear dipolar interactions. On the other hand, the γ-encoded symmetry sequences for σ2-CSA recoupling have smaller scaling factors but they efficiently suppress the homonuclear dipole-dipole interactions. Therefore, the latter family of sequences is applicable for measurements of CSA parameters in systems with strong homonuclear dipolar couplings, such as uniformly-13C labeled biological solids. We demonstrate RNCSA NMR experiments and numerical simulations establishing the utility of this approach to the measurements of 13C and 15N CSA parameters in model compounds, [15N]-N-acetyl-valine (NAV), [U-13C, 15N]-alanine, [U-13C,15N]-histidine, and present the application of this approach to [U-13C/15N]-Tyr labeled C-terminal domain of HIV-1 CA protein.
INTRODUCTION
Orientation-dependent spin interactions in nuclear magnetic resonance (NMR), such as chemical shift anisotropy (CSA), bear a wealth of information about molecular structure and dynamics.1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13 Even though select non-isotropic properties of chemical shift tensors can be obtained through solution-state NMR approaches, solid-state NMR spectroscopy is far more suitable for deriving the anisotropic information.14 In solids, CSA can be directly measured by recording powder patterns in static powder samples, but these experiments suffer from poor sensitivity, spectral overlap when multiple chemical sites are present, and from broadening and distortion to the CSA line shapes introduced by homonuclear dipolar couplings. Under magic angle spinning (MAS), the CSA interactions are averaged out provided sufficiently high spinning frequencies, giving rise to highly resolved isotropic spectra. Numerous methods have been developed to reintroduce the anisotropic chemical shift interactions in the indirect dimensions under MAS conditions.15, 16, 17, 18, 19, 20, 21, 22, 23, 24, 25, 26, 27, 28, 29, 30, 31, 32 For most of these recoupling methods, determination of the CSA parameters requires analysis of the spinning sideband patterns16, 21, 23, 26, 27, 28, 29, 31, 32 or powder patterns,15, 17, 18, 19, 20, 22, 24, 25, 30 and usually periodic radio frequency (rf) field irradiation is applied in synchrony with the MAS sample rotation during the evolution period. In these recoupling techniques, the required rf field strengths are generally so high that, in practice, these sequences are only applicable under low or moderate MAS conditions. In addition, since homonuclear dipole-dipole interactions cannot be suppressed efficiently, most of the existing recoupling methods are not suitable for CSA measurements in strongly coupled systems, i.e., uniformly 13C enriched samples.
In this work, we demonstrate that R-type symmetry pulse sequences33, 34, 35, 36 are well suited for recoupling of CSA interactions under MAS. Two classes of γ-encoded RNnv symmetry sequences are discussed, which are designed for recoupling of either the first-rank (σ1) or the second-rank (σ2) spatial CSA components. We have recently explored a subset of these sequences for the measurement of the relative orientations of the CSA and dipolar tensors under moderate MAS conditions.37 In this work, we analyze the general properties of these sequences and show that they are suitable for CSA recoupling under a wide range of MAS frequencies, including fast-MAS conditions with rotation frequencies of 25 kHz and above. We demonstrate that a specific combination of symmetry numbers (N, n, v) can be tailored to the MAS frequency range of interest within the practically attainable rf field strength. Furthermore, these R-symmetry sequences are not very sensitive to the rf field inhomogeneities, permitting accurate measurements of CSA tensors in samples with inherently low sensitivity or in hydrated samples, such as microcrystalline proteins and protein assemblies. As we demonstrate in this report, these sequences are suitable for CSA measurements in both isotopically enriched and natural abundance systems.
Our results indicate that the R-symmetry sequences for σ1-CSA recoupling generally have larger scaling factors than those for the σ2-CSA recoupling. At the same time, the first-order average homonuclear dipolar Hamiltonian terms are not fully suppressed to zero in the σ1-CSA sequences, which makes them suitable only for CSA measurements in systems with weak homonuclear dipolar interactions. In contrast, the γ-encoded symmetry sequences for σ2-CSA recoupling have smaller scaling factors but they suppress efficiently the homonuclear dipole-dipole interactions. Therefore, the latter family of sequences is well suited for the measurements of CSA parameters in systems with strong homonuclear dipolar couplings, such as uniformly-13C labeled biological solids. We present RNCSA experiments and simulations establishing the utility of this approach to the measurements of 13C and 15N CSA parameters in model compounds, [15N]-N-acetyl-valine (NAV), [U-13C, 15N]-alanine (Ala), [U-13C,15N]-histidine, and present the application of this approach to [U-13C/15N]-Tyr labeled C-terminal domain of HIV-1 CA protein.
EXPERIMENTS AND METHODS
Materials
[U-15N] NAV, [U-13C, 15N]-L-histidine (L-His), [U-13C, 15N]-Ala and natural abundance L-alanine were purchased from Cambridge Isotope Laboratories. Powder samples of NAV and Ala were used in the subsequent NMR experiments without any further purification or recrystallization. L-His was doped with 0.1 mol. % CuCl2 and recrystallized before solid-state NMR experiments. The conical assemblies of U-13C,15N-Tyr-labeled C-terminal domain (CTD) of HIV-1 CA protein were prepared by controlled precipitation from 50% w/v solution of PEG-4000 at the ratio of 1:1 (v/v) with the final protein concentration of 16 mg/mL, as reported previously.38, 39
Solid-state NMR spectroscopy
All NMR experiments were carried out on a 14.1 T Varian InfinityPlus narrow bore solid-state NMR spectrometer, operating at a Larmor frequency of 599.8 MHz for 1H, 150.8 MHz for 13C, and 60.8 MHz for 15N. A 3.2 mm Varian MAS triple-resonance T3 probe, a 1.6 mm Varian fast-MAS triple-resonance probe, and a 1.8 mm fast-MAS triple-resonance probe developed in the Ago Samoson Laboratory were used. The model compounds [U-15N]-NAV and [U-13C, 15N]-Ala were packed into 3.2 mm rotors, and all spectra were recorded at MAS frequencies of 10 and 20 kHz, controlled to within ±0.005 kHz. The n.a. alanine was packed into 1.6 mm rotor, and all spectra were recorded at MAS frequency of 10 kHz. The HIV-1 CTD CA protein and Cu(II)-doped L-His were packed into 1.8 mm rotors, and their spectra were recorded at MAS frequencies of 10 and 25 kHz. To reduce the sample heating during MAS, nitrogen gas was used for cooling, resulting in a final sample temperature of 20 °C for the three model samples, and of −25 °C for U-13C, 15N-Tyr labeled CTD CA protein. The temperature was calibrated for different MAS frequencies using a PbNO3 temperature sensor,40 and the actual temperature at the sample was maintained to within ±0.5 °C throughout the experiments using the Varian temperature controller.
For NMR experiments, a 2D RNCSA pulse sequence shown in Figure 1a was used. A series of 2D NMR spectra were recorded by applying different RNnv symmetry pulse irradiation during t1. The basic R element was a π pulse; the rf field strength (N/2n·ωR) and the phase (±v/N · 180°) are determined by the symmetry properties for each of the symmetry sequences used.34, 35, 36, 39, 41, 42, 43 During the RNnv symmetry pulse irradiation on nucleus X (X = 13C or 15N), a π pulse was applied at the center of each R cycle (nτr) on nucleus Y to decouple the X-Y heteronuclear dipolar interactions (X, Y = 13C or 15N), as shown in Figure 1b. High continuous-wave (CW) or two-pulse phase-modulated (TPPM) proton decoupling with rf field of 90–110 kHz was applied during the RN CSA recoupling period, and the actual 1H decoupling rf field was chosen so as to avoid 1H–13C/15N Hartmann-Hahn matching conditions (ω1H – ω1X > 3ωR or ω1H – ω1X ≠ nωR). Sixteen transients were added for each t1 increment (dw = nτr), and a total of 32 t1 increments were used to record the spectra for NAV, Ala, and His. For 2D RNCSA experiments on U-13C,15N-Tyr-CTD CA protein, 4096 and 3072 transients were accumulated for each t1 increment in the R813-based 15N σ1-CSA and R1214-based 13C′σ2-CSA measurements, respectively, and the same transients were used in the corresponding 2D recoupling of chemical shift anisotropy (ROCSA) experiments. The pulse delay was 2 s.
Numerical simulations
Numerical simulations of 13C/15N σ1- and σ2-CSA powder spectra were performed using the SIMPSON software package.44 To produce a powder average, 986 pairs of {α, β} angles generated according to the ZCW algorithm45 and 16 γ angles were used for all simulations, resulting in a total of 15 776 angle triplets. For extracting the best-fit CSA parameters (δσ, ησ), all of the experimental and processing parameters (i.e., Larmor frequency, MAS frequency, rf field strength, number of t1 points, finite pulse lengths, zero-filling, line broadening, etc.) were taken into account in the simulations for each experiment. Haeberlen-Mehring-Spiess convention was followed to define the CSA parameters, where the isotropic value δiso, the reduced anisotropy δσ, the anisotropy Ω, and the asymmetry parameter η, are related to the principal elements of the chemical shift tensor according to |δzz − δiso| ⩾ |δxx − δiso| ⩾ |δyy − δiso|, δiso = 1/3(δxx + δyy + δzz), δσ = δzz − δiso = 2/3Ω, and η = (δyy − δxx) / (δyy − δiso).
RESULTS AND DISCUSSION
γ-encoded σ1- and σ2-CSA recoupling by RNnv symmetry sequences
The rotational properties of anisotropic spin interactions under MAS conditions allow us to reintroduce the MAS-averaged anisotropic couplings by synchronization of nuclear spin degrees of freedom with rf field irradiation and MAS rotor frequency, in an appropriately designed sequence. The symmetry-based theory33, 34, 36, 41, 42 introduced and developed by Levitt and co-workers provides a general principle for designing rotor-synchronized rf pulse sequences to selectively recouple and/or decouple various anisotropic spin interactions in MAS NMR spectroscopy. The symmetry-based approaches are classified as CNnv and RNnv schemes, depending on whether a “Cycle” or “Reverse” operation is applied on the irradiated spins by a basic pulse element. The symbols N, n, and v are small integers and are referred to as the symmetry numbers of the pulse sequence. When the rf field irradiation is composed of the periodic RNnv symmetry pulses, the selection rules for the first-order average Hamiltonian are expressed as
(1) |
where Zλ is an integer with the same parity as λ, which is defined according to the rotational properties of the spin interactions.33, 34, 35, 36 The first-order average Hamiltonian term in Equation 1 can be expressed with the Magnus expansion of the effective Hamiltonian in the interaction frame,
(2) |
where Kmλμ, , and denote the scaling factor, the component of the spatial tensor and the component of the spin tensor, respectively. Each single Hamiltonian component is γ-encoded with its magnitude independent of the Euler angle γ. With specially designed symmetry sequences, a given single or multiple types of interactions can be recoupled selectively. The average CSA Hamiltonian interaction can be separated into three terms according to the spatial rank m = 0, ±1, ±2,37
(3) |
where σ0, σ1, and σ2 coefficients are dependent on the three principal components of the CSA tensor and on the crystallite orientations, and the recoupled CSA pattern of each spatial Hamiltonian term reveals all the properties of the CSA interactions.
The explicit expressions for σ0, σ1, and σ2 coefficients are
(4) |
(5) |
(6) |
where σcosi and σsini (i = 1 and 2) are the projected elements of the spatial ith-rank CSA Hamiltonian term (σi) in the x′y′ plane of the rotor fixed frame (RFF), δi denotes the projection angle of CSA Hamiltonian σi relative to the x′ axis of the RFF.37
Depending on the spatial rank number l and spin rank number λ of the tensorial interaction of interest, it is possible, using a suitable symmetry sequence, to reintroduce selectively the Hamiltonian components characterized by quantum numbers {l, m, λ, μ}. For the γ-encoded recoupling of CSA interaction with spatial rank number l = 2, either the first spatial component σ1-CSA or the second spatial component σ2-CSA can be reintroduced under the MAS conditions; these components correspond to the Hamiltonian terms {2, ±1, 1, ∓1} and {2, ±2, 1, ∓1}, respectively. It can be immediately seen that, in the regime of double-quantum homonuclear dipolar recoupling, when the first-rank spatial components (σ1-CSA) are recoupled by the RNnv schemes, the homonuclear dipole-dipole Hamiltonian components with quantum numbers {2, ±2, 2, ∓2} are recoupled as well. These recoupled σ1-CSA interactions and homonuclear dipolar couplings interfere with each other, which would result in inaccuracy or uncertainty of the derived CSA determinations. Therefore, γ-encoded σ1-CSA recoupling symmetry schemes are only suitable for systems that have either no or weak homonuclear dipolar interactions, such as 31P and 15N in dilute environments or naturally abundant 13C spins.
Figure 2 illustrates an example of the selection properties of anisotropic Hamiltonian interactions by R-type symmetry sequences R1013 (a) and R1014 (b). It can be seen that both of these sequences are suitable for γ-encoded single-quantum CSA recoupling, and the symmetry-allowed Hamiltonian components retained by R1013 and R1014 are {l, m, λ, μ} = {2, ±2, 1, ∓1} and {2, ±1, 1, ∓1}, respectively. R1014 symmetry sequence recouples σ1-CSA interactions (the first spatial rank), while σ2-CSA (the second spatial rank) is recoupled by R1013. As discussed above, usually the homonuclear dipolar interaction would be recoupled partially by the σ1-CSA recoupling symmetry sequence. In the case of the R1014 symmetry sequence, the components of the dipolar Hamiltonian with quantum numbers {2, ±2, 2, ∓2} are symmetry-allowed, as shown in the spin-space selection (SSS) diagram in Figure 2. Additionally, it should be noted that these γ-encoded σ1- and σ2-CSA symmetry sequences also reintroduce heteronuclear dipolar interactions since CSA and heteronucear dipolar interactions exhibit the same rotational properties under MAS. Heteronuclear decoupling, by CW, TPPM, or XiX (X inverse-X) irradiation or any other suitable sequence, is therefore required during the CSA evolution period. Alternatively, the reintroduced heteronuclear dipolar couplings can be refocussed easily with a series of π pulses located at the center of each R cycle, as shown in Figure 1b, and such π pulse-based refocusing is advantageous as it avoids the sample heating by rf field irradiation.
Scaling factors for σ1- and σ2-CSA recoupling
The R-type symmetry sequences suitable for σ1- and σ2-CSA recoupling under MAS are summarized in the supplementary material (see Table S1).46 The symmetry numbers of the sequences listed in Table S1 are limited to the range of 6 ≤ N ≤ 20, and the ratios of the symmetry numbers are limited to 1.0 < N/2n ≤ 8.0, to yield rf powers compatible with the available modern hardware. If the basic R element is a π pulse, the rf field strength required for the RNnv symmetry sequences is NωR/2n, and the different sequences exhibit different scaling factors for recoupling of σ1- or σ2- CSA interactions and for decoupling of homonuclear dipole-dipole interactions. All the σ2-CSA recoupling R-type symmetry sequences except for R611 and R812 can suppress the first-order homonuclear dipolar Hamiltonian to zero; however, there are always partial homonuclear dipolar Hamiltonian components reintroduced simultaneously while the σ1-CSA interactions are recoupled by γ-encoded RNnv symmetry sequences. In Figure 3, the effective scaling factors for the σ1- and σ2-CSA recoupling by RNnv symmetry sequences are plotted as a function of the symmetry number ratio, NωR/2n. As illustrated in this figure, the symmetry sequences with higher N/n ratio have larger scaling factors for both σ1- and σ2-CSA recoupling, and the scaling factors are reduced greatly when the ratio N/2n is lower than 2.0. Notably, the σ1-CSA recoupling schemes have at least 1.4-fold higher scaling factors than the σ2-CSA recoupling schemes with the same symmetry number ratio N/n. This higher scaling factor in σ1-CSA recoupling might be advantageous, especially at low magnetic fields, as it enables accurate measurements of small CSA values, even though these experiments are restricted to the spin systems with weak homonuclear dipolar couplings. Another advantage of the σ1-CSA recoupling schemes is that they are less sensitive to the required rf field strength. On the other hand, for the measurement of large CSA interactions (e.g., in 13C carbonyl atoms or in heavy nuclei, such as 207Pb), σ2-CSA recoupling sequences with smaller scaling factors would be more suitable, especially at high magnetic fields. For a given MAS frequency, it is generally the best to employ RNnv symmetry sequences with higher N/2n ratio for accurately determining CSA interactions, as long as the required rf field strength (NωR/2n) can be attained in the MAS NMR probes available to the experimentalist.
15N CSA recoupling by γ-encoded RNnv sequences
To understand the performance of the RNCSA recoupling with the RN-based pulse scheme shown in Figure 1, we simulated 15N σ1- and σ2-CSA line shape patterns for the R1014 and R1013 symmetry sequences, at the MAS frequency of 10 kHz. The resulting line shapes are shown in Figure S1 of the supplementary material.46 It can be seen that the CSA parameters can be accurately captured by both σ1- and σ2-CSA recoupled line shape patterns, and the line shapes are very similar in appearance except for the size of the scaling factors. These simulated spectra suggest that R-type symmetry sequences should work well for CSA recoupling under MAS conditions, that both the anisotropy and asymmetry parameters of the CSA tensor are available from each individual experiment. In practice, a single measurement is sufficient for extracting accurate CSA parameters. As shown below, the choice of a recoupling sequence for each measurement of interest is dictated by the system under study and by the available experimental settings (spectrometer hardware).
Following the results of the numerical simulations, we performed 15N σ1- and σ2-CSA measurements on [15N]-NAV spun at the MAS frequency of 10 kHz. Figure 4 shows the 15N RNCSA line shapes recorded by the various symmetry sequences designed for σ2-CSA recoupling (R1825 (a), R1013 (b), and R1214 (c)) and for σ1-CSA recoupling (R813 (d), R1014 (e), and R1215 (f)). The rf field strengths applied on 15N during the RNCSA recoupling period at this MAS frequency are 5N/n kHz. All these RNnv symmetry sequences produce similar 15N CSA line shapes, and the σ1-CSA recoupled line shapes (right) show much larger scaling factors than the σ2-CSA line shapes (left), in accord with the theory and simulations. For both σ1-CSA and σ2-CSA recoupling measurements, the symmetry sequences with higher symmetry number ratio of N/n give rise to higher scaling factors, i.e., R1215 > R1014 > R813, as expected. The 15N CSA parameters were extracted from numerical simulations of each line shape, and the simulated line shapes are displayed as dotted lines in Figure 4.
Since the 15N CSA tensor components, reduced anisotropy δσ and asymmetry parameter η, are the primary parameters determining the features of CSA line shape patterns recoupled by R-symmetry sequences, the best-fit line shape can be readily derived, using the minimal least square error criterion, χ2. It should be noted that the central part (usually the entire center peak) is excluded from the curve fitting when minimizing χ2, due to its complex dependence on rf field inhomogeneity, multiple relaxation processes and the recoupled second-order Hamiltonian terms. The exclusion of the center peak from the simulations does not affect the accuracy of the derived CSA parameters to any significant extent. The fit parameters as well as the uncertainty errors are derived using the SIMPLEX method, as shown in Figure S2 of the supplementary material.46 In Figure S2a, a χ2 contour plot is depicted for the fitting result of the 15N σ1-CSA line shape recorded by R1014 symmetry sequence, from which the best-fit values are determined to be δσ = 105.8 ± 0.5 ppm and η = 0.19 ± 0.04. These results are consistent with our previous report.37 Table 1 lists the 15N CSA parameters extracted from the σ1- and σ2-CSA measurements performed with various RNnv symmetry sequences. It can be seen that the 15N CSA parameters derived from all RNCSA experiments are in excellent agreement. The average values for the reduced anisotropy and asymmetry parameters recorded with the rest of the sequences are δσ = 105.9 ± 0.5 ppm and η = 0.20 ± 0.05.
Table 1.
N | n | v | δσ (ppm) | ησ |
---|---|---|---|---|
6 | 1 | 2 | 105.1 | 0.23 |
8 | 1 | 3 | 105.7 | 0.21 |
10 | 1 | 3 | 106.2 | 0.18 |
10 | 1 | 4 | 105.8 | 0.19 |
12 | 1 | 4 | 108.9 | 0.18 |
12 | 1 | 5 | 106.5 | 0.17 |
14 | 2 | 3 | 104.9 | 0.21 |
14 | 2 | 5 | 105.4 | 0.20 |
18 | 2 | 5 | 105.3 | 0.19 |
Static NMR | 107.2 | 0.19 |
Note: The MAS frequency was 10 kHz, and the rf field strength was 5N/n kHz for each RNnv symmetry sequence.
To verify the accuracy of CSA parameters determined by the R-symmetry sequences, static 15N CP NMR experiment was performed on 15N-NAV sample to record the 15N CSA powder pattern. The results are shown in Figure S2b of the supplementary material.46 The best-fit simulation yielded the following 15N CSA parameters: δσ = 107.2 ppm and η = 0.19, which agrees well with the corresponding values derived from the R-symmetry based experiments conducted under MAS conditions. Since the intermolecular homonuclear 15N–15N dipolar interactions are weak enough to be negligible, the 15N σ1-CSA measurements are as accurate as σ2-CSA experiments. The encouraging consistency of 15N CSA parameters extracted from these independent experiments illustrates the accuracy of the current RNCSA approach and that σ1-CSA recoupling technique is suitable for U-15N isotope-enriched systems.
As pointed out by us and by others in the case of dipolar recoupling,39, 47 R-symmetry based sequences are sensitive to the rf field inhomogeneity. At the same time, we have demonstrated that the sensitivity to the rf field inhomogeneity can be reduced significantly by choosing the appropriate symmetry sequences with symmetry ratio of N/2n > 2.5.39 It is thus important to consider the effect of rf field inhomogeneity on RNCSA line shapes. We have conducted numerical simulations and discovered that the rf inhomogeneity has more pronounced effect on the σ2-CSA RN symmetry sequences, especially for the sequences with smaller symmetry ratio of N/2n. These findings are summarized in Figure S3 of the supplementary material.46 In contrast, σ1-CSA R-symmetry sequences with relatively large scaling factors exhibit much lower sensitivity to the rf field inhomogeneity. The manifestation of the rf field inhomogeneity is an increase in the intensity of the central peak and a broadening of the RNCSA patterns, which become more pronounced with the increased rf field inhomogeneity. The simulations also reveal the fact that for either σ1-CSA or σ2-CSA R-symmetry sequences, the stronger the rf field (NωR/2n) is, the weaker the effect from rf field inhomogeneity. Generally, the effect from rf field inhomogeneity of up to 20% can be ignored when the symmetry ratio, N/2n, of the sequence employed is greater than 2.5. In practical terms, the above implies that one has to consider the trade-off between the scaling factor and the rf field inhomogeneity of a particular probe. It should be noted that the rf field inhomogeneity was not taken into account for all the RNCSA fittings in the present work because the 1.8 mm and 1.6 mm MAS probes used have extremely high rf field homogeneity (>90%), and also because the RN sequences used for all the current measurements have the symmetry ratio of N/2n > 2.5.
13C CSA recoupling by γ-encoded RNnv sequences
We also examined the performance of these γ-encoded RNnv symmetry sequences for determining 13C CSA interactions in both naturally abundant and isotopically enriched systems. Figure 5 shows the 13C experimental and simulated CSA line shapes for all of the carbon sites in an U-15N-NAV sample spun at the MAS frequency of 10 kHz, recorded with the R1014 sequence (σ1-CSA recoupling, right) and R1013 sequence (σ2-CSA recoupling, left). Similar to the 15N experiments, the fitted 13C CSA parameters as well as the uncertainty errors can be easily derived using the SIMPLEX method for each carbon site, as listed in Table 2. The fact that the 13C CSA parameters extracted from R1014σ1-CSA and R1013σ2-CSA experiments are in excellent agreement indicates that σ1-CSA recoupling technique is suitable for 13C CSA measurements in natural-abundance systems. Moreover, the 13C CSA parameters measured from these independent R-based experiments are consistent with the literature values derived on the basis of ROCSA spectra,25 indicating that these γ-encoded symmetry sequences yield highly accurate CSA estimates, even for the sites with small CSA.
Table 2.
R1013 |
R1014 |
|||||
---|---|---|---|---|---|---|
# | δσ (ppm) | ησ | δσ (ppm) | ησ | δσ (ppm)2 | ησ2 |
Cα | 26.3 | 0.48 | 24.6 | 0.51 | 26.0 | 0.36 |
Cβ | 10.3 | 1.0 | 10.8 | 1.0 | 11.0 | 1.0 |
C1 | 21.8 | 0.69 | 21.2 | 0.70 | … | … |
Cγ1 | 19.0 | 0.59 | 18.9 | 0.61 | 18.5 | 0.58 |
Cγ2 | 18.1 | 0.32 | 19.0 | 0.30 | 17.5 | 0.65 |
Co | 84.6 | 0.50 | 83.6 | 0.55 | 85.4 | 0.49 |
Note: R1013 and R1014 symmetry sequences were employed for σ2- and σ1-CSA recoupling. The MAS frequency was 10 kHz. Note that recoupling of 13C CSA is efficiently performed with these sequences for the natural abundance carbon sites in this sample.
Data reported for U-13C,15N-val enriched NAV sample (Reference 25).
The σ2-CSA symmetry-based recoupling sequences can be applied not only to natural abundance but also to uniformly 13C labeled systems due to the inherent capability of these sequences to suppress 13C–13C homonuclear dipolar couplings. An example of 13C CSA measurements in U-13C,15N-alanine using various σ2-CSA symmetry sequences is given in Figure S4 of the supplementary material.46 The best-fit 13C CSA parameters for each carbon site are summarized in Table 3. It can be seen that the 13C CSA parameters extracted from experiments recorded with different symmetry sequences are in good agreement and consistent with the literature values,25 with the average CSAs for Cα, Cβ, and C′ of 22.0, 13.8, and 68.6 ppm, respectively.
Table 3.
C′ |
Cα |
Cβ |
||||||
---|---|---|---|---|---|---|---|---|
N | n | v | δσ (ppm) | ησ | δσ (ppm) | ησ | δσ (ppm) | ησ |
14 | 2 | 3 | 68.5 | 0.87 | 21.9 | 0.60 | 13.5 | 0.65 |
18 | 2 | 5 | 68.4 | 0.77 | 22.2 | 0.58 | 14.1 | 0.75 |
10 | 1 | 3 | 69.6 | 0.80 | 21.2 | 0.72 | 14.3 | 0.62 |
12 | 1 | 4 | 67.7 | 0.74 | 22.5 | 0.52 | 13.2 | 0.97 |
Note: The MAS frequency was 10 kHz, and the rf field strength was 5N/n kHz for each RNnv symmetry sequence.
For uniformly 13C-labeled systems, since the partially recoupled 13C–13C dipolar interactions would interfere with the 13C σ1-CSA interaction, the σ1-CSA recoupling technique might not be suitable for dense networks of spins. To examine this hypothesis, we simulated the σ1-CSA and σ2-CSA line shapes in the presence of remote homonuclear spins. The results shown in Figure S5 of the supplementary material46 indicate that indeed, the σ1-CSA line shapes are broadened and distorted when dipolar-coupled homonuclear spins are present. Experimental results agree with these simulations, as shown in Figure S6 of the supplementary material:46 in a σ1-CSA recoupling measurements in U-13C,15N-Ala and natural abundance Ala samples, the σ1-CSA line shapes of the 13Cα and 13Cβ atoms in isotopically labeled Ala is highly distorted when recorded with R1215 symmetry sequence, as it deviates significantly from that of natural abundance Ala. This is due to the interference from homonuclear 13C–13C dipolar couplings. It should be noted that the degree of distortion of the CSA patterns is mostly dependent on the ratio of the magnitude of 13C–13C dipolar interactions to that of CSA interactions, and 13Cβ with the smallest CSA displays the largest line shape distortion. On the contrary, the recoupled σ2-CSA line shapes of isotopically labeled Ala are not affected at all by the additional homonuclear dipolar couplings, and we record the same powder patterns as for the natural abundance Ala, as illustrated in Figure S6 in the supplementary material.46
Notably, the fact that a variety of symmetry numbers are suitable for CSA recoupling makes these experiments applicable for a wide range of MAS frequencies, including fast MAS conditions. We have performed 13C σ2-CSA measurements on U-13C,15N-histidine spun at the MAS frequency of 25 kHz. As discussed above, the RNnv symmetry sequences for σ1-CSA recoupling have larger scaling factors, but they cannot suppress the homonuclear 13C–13C dipole-dipole couplings sufficiently well and give rise to distorted CSA line shapes thus affecting the accuracy of the measurements. The experimental and simulated 13C CSA line shapes for all of the carbon sites of histidine recorded by R1423 symmetry sequence with an rf field strength of 87.5 kHz, as shown in the left panel of Figure 6. As is clear from the figure, the experimental and the simulated CSA line shapes agree very well attesting to the fact that γ-encoded R-symmetry based sequences are suitable for CSA recoupling under fast MAS conditions. We also performed 13C σ2-CSA measurement with R2034 symmetry sequence at the MAS frequency of 25 kHz (see Figure S7 in the supplementary material46 for the details of NMR experiments and simulations). The CSA parameters extracted from this experiment are consistent with those determined by the R1423 symmetry sequence, illustrating that both large and small CSA interactions can be measured with high accuracy.
We have compared the 13C CSA line shapes recorded by the above R-symmetry sequences with those extracted from the ROCSA25 experiment at a MAS frequency of 10 kHz. The experimental and simulated 13C CSA line shapes for all of the carbon sites are shown on the right panel of Figure 6. As illustrated in Table 4, the best-fit 13C reduced anisotropies for all carbon sites are systematically lower in the ROCSA experiments. These lower values are the result of high sensitivity of the ROCSA conditions to the rf field inhomogeneity and rf power settings: even the slightest imperfections in the hardware and experimental conditions (which are often inevitable in biological samples) give rise to inaccurate CSA parameters. Severe distortions are present in the ROCSA 13C CSA patterns, especially for carbon groups with larger CSAs. In contrast, the R-symmetry based recoupling sequences are much more robust and tolerant to the hardware and experimental imperfections, especially when the symmetry ratio N/2n is greater than 2.5.
Table 4.
R1423 |
R2034,2 |
ROCSA |
||||
---|---|---|---|---|---|---|
# | δσ (ppm) | ησ | δσ (ppm) | ησ | δσ (ppm) | ησ |
Cα | 16.9 ± 0.6 | 0.46 ± 0.11 | 17.6 ± 0.9 | 0.58 ± 0.16 | 15.7 ± 1.6 | 0.55 ± 0.19 |
Cβ | 14.5 ± 2.2 | 0.93 ± 0.44 | … | … | 8.1 ± 2.6 | 0.97 ± 0.85 |
Cγ | 75.8 ± 2.9 | 0.87 ± 0.15 | 77.3 ± 0.5 | 0.80 ± 0.03 | 69.0 ± 4.3 | 1.00 ± 0.11 |
Cδ | 71.7 ± 3.4 | 1.00 ± 0.24 | 71.0 ± 2.2 | 0.88 ± 0.06 | 67.6 ± 0.3 | 1.00 ± 0.57 |
Cɛ | 71.8 ± 2.1 | 0.83 ± 0.08 | 71.0 ± 0.9 | 0.76 ± 0.11 | 70.0 ± 3.9 | 0.76 ± 0.09 |
Co | 66.0 ± 1.1 | 1.00 ± 0.45 | 68.1 ± 4.7 | 0.93 ± 0.17 | 64.8 ± 3.6 | 1.00 ± 0.04 |
Note: R2034 and R1423 symmetry sequences were employed for σ2-CSA recoupling. The rf field strengths were 83.3 and 87.5 kHz, respectively, and the MAS frequency was 25 kHz. TPPM 1H decoupling with rf field strength of 100 kHz was applied during the RNCSA period. The results of ROCSA recoupling are presented for comparison.
The experimental and simulated 13C CSA line shapes for each carbon site are shown in the supplementary material.46
We also note that due to the limitations on the 1H rf field strength for heteronuclear decoupling in our NMR probe (ω1Hmax ≈ 110 kHz), it is not possible to avoid 1H–13C Hartmann-Hahn matching conditions during the CSA recoupling period especially under fast MAS conditions. Therefore, with our hardware we could not pursue the R-based CSA recoupling experiments at MAS frequencies exceeding 25 kHz. However, with the availability of ultrafast MAS probes capable of delivering high-power 1H rf field irradiation the R-symmetry based CSA recoupling will be attainable at frequencies higher than 25 kHz.
γ-encoded CSA recoupling: Applications to protein structural and dynamics studies
The γ-encoded symmetry-based σ1-CSA and σ2-CSA recoupling methods described here are well suited for structural and dynamics characterization of uniformly and sparsely enriched proteins and protein assemblies. 15N and 13C′ CSA interactions of the backbone atoms provide quantitative insights into protein structure and dynamics. We have examined the performance of the R-symmetry based recoupling sequences for the determination of 15N σ1-CSA and 13C′σ2-CSA interactions in U-13C,15N-Tyr-enriched C-terminal domain (CTD) of HIV-1 CA capsid protein. The C-terminal domain of HIV-1 CA protein contains three tyrosine residues, Y145, Y164, and Y169. Y164 and Y169 are located in α-helices, while Y145 occupies a pivotal position in the hinge region connecting the C- and N-terminal domains of CA. The hinge region is conformationally flexible on millisecond timescales,39, 48, 49, 50, 51 and as we have recently demonstrated, these millisecond motions are related to conformational plasticity of CA, permitting its assembly into different morphologies (i.e., conical, tubular, and spherical).51
We have recorded the 15N σ1-CSA line shapes for all Tyr residues in U-13C,15N-Tyr-CTD by R813 symmetry sequence. The 15N CSA parameters extracted by numerical simulations of the experimental RNCSA and ROCSA line shapes are shown in Figure 7 and they are in excellent agreement with each other. The 15N reduced anisotropies, δσ, are similar for all tyrosine residues, and close to the rigid limit value (δσ = 110 ppm52). The asymmetry parameters, ησ, are also similar and nearly axially symmetric, between 0.27 and 0.38. This result is fully consistent with our recent studies revealing no significant averaging for the 15N CSA tensor of Y145 and indicating that the backbone nitrogen is rigid on the timescales faster than ∼10−6 s.39, 51
In our prior work, we were limited to the ROCSA-based measurements of 15N CSA parameters. We have previously attempted to record 13C′ CSA line shapes by the ROCSA sequence. As shown in the right panel of Figure 8, large distortions were observed in these line shapes, which precluded determination of accurate CSA parameters for these carbonyl sites and generally for sites with large CSAs under the experimental conditions attained with our hardware. In contrast, the R-symmetry based sequences discussed here enable the measurements of much larger 13C′ chemical shift anisotropies, with high sensitivity and only half of ROCSA experiment time. For carbonyl CSA measurement, we have employed R1214 symmetry sequence for σ2-CSA recoupling, as shown in the left panel of Figure 8. In Figure 8, the experimental (solid lines) and best-fit simulated (dashed lines) 13C′ CSA line shapes for each Tyr residue are presented. The Y145 and Y169 C′ peaks overlap, and therefore the corresponding line shape is a combination of contributions arising from both residues. Y164 and Y169/Y145 exhibit 13C′δσ values of 77.7 and 80.4 ppm, respectively. These values are close to the rigid limit CSA for carbonyl backbone carbons (δσ = 80 ppm53, 54), and indicate that no dynamic averaging is taking place on timescales of microseconds and faster, in full agreement with our 15N CSA and 1H–15N dipolar coupling results obtained in this and in recent work.39, 51
The above results demonstrate that γ-encoded R-type symmetry sequences are well suited for the measurement of large CSA interactions.
Taken together, the results presented in this report demonstrate that RNnv symmetry sequences permit recoupling of CSA interactions in a broad regime of experimental conditions, and offer a reliable route to site-specific measurements of chemical shift interactions in a variety of samples, including biological solids.
CONCLUSION
The γ-encoded R-type symmetry sequences are well suited for the measurements of CSA interactions under magic angle spinning. With the appropriately selected γ-encoded RNnv symmetry sequences either first-rank (σ1) or second-rank (σ2) spatial CSA recoupling can be attained. Both types of γ-encoded RNCSA symmetry schemes are applicable to a wide range of MAS frequencies, including fast MAS conditions. While σ1-CSA recoupling symmetry sequences exhibit large scaling factors and are advantageous for recoupling of small CSAs, the partial homonuclear dipolar Hamiltonian components being symmetry allowed, in practice make these sequences suitable for CSA measurements only in systems with weak or no homonuclear dipolar interactions. On the other hand, even though γ-encoded σ2-CSA recoupling symmetry sequences have smaller scaling factors, they efficiently suppress homonuclear dipole-dipole interactions. Therefore, these σ2-sequences are suitable for CSA measurements in the samples where homonuclear dipolar couplings are present, such as in U-13C labeled biological solids. These sequences are also advantageous at high magnetic fields and in systems possessing inherently large CSAs, such as 13C carbonyl sites in biological solids and heavy nuclei. We expect that the approach reported here will be widely used for structural and dynamics characterization of a broad range of systems, ranging from macromolecular assemblies to organic solids, and will find many interesting applications in chemistry, biology, materials science, and other disciplines.
ACKNOWLEDGMENTS
This work was supported by the National Institutes of Health (NIH) (NIGMS Grant Nos. P50GM082251 and 8P30GM103519-03, and NCRR Grant No. P30RR031160-03) and is a contribution from the Pittsburgh Center for HIV Protein Interactions.
References
- Veeman W. S., Prog. Nucl. Magn. Reson. Spectrosc. 16, 193 (1984). 10.1016/0079-6565(84)80006-0 [DOI] [Google Scholar]
- DeDios A. C., Pearson J. G., and Oldfield E., Science 260, 1491 (1993). 10.1126/science.8502992 [DOI] [PubMed] [Google Scholar]
- Tjandra N., Szabo A., and Bax A., J. Am. Chem. Soc. 118, 6986 (1996). 10.1021/ja960510m [DOI] [Google Scholar]
- Case D. A., Curr. Opin. Struct. Biol. 8, 624 (1998). 10.1016/S0959-440X(98)80155-3 [DOI] [PubMed] [Google Scholar]
- Lee D. K., Wittebort R. J., and Ramamoorthy A., J. Am. Chem. Soc. 120, 8868 (1998). 10.1021/ja981599u [DOI] [Google Scholar]
- Palmer A. G., Annu. Rev. Biophys. Biomol. Struct. 30, 129 (2001). 10.1146/annurev.biophys.30.1.129 [DOI] [PubMed] [Google Scholar]
- Chekmenev E. Y., Xu R. Z., Mashuta M. S., and Wittebort R. J., J. Am. Chem. Soc. 124, 11894 (2002). 10.1021/ja026700g [DOI] [PubMed] [Google Scholar]
- Sun H. H., Sanders L. K., and Oldfield E., J. Am. Chem. Soc. 124, 5486 (2002). 10.1021/ja011863a [DOI] [PubMed] [Google Scholar]
- Bim J., Poon A., Mao Y., and Ramamoorthy A., J. Am. Chem. Soc. 126, 8529 (2004). 10.1021/ja049879z [DOI] [PMC free article] [PubMed] [Google Scholar]
- Wi S., Sun H. H., Oldfield E., and Hong M., J. Am. Chem. Soc. 127, 6451 (2005). 10.1021/ja042935b [DOI] [PubMed] [Google Scholar]
- Wylie B. J., Franks T., Graesser D. T., and Rienstra C. M., J. Am. Chem. Soc. 127, 11946 (2005). 10.1021/ja053862e [DOI] [PubMed] [Google Scholar]
- McDermott A. and Polenova T., Curr. Opin. Struct. Biol. 17, 617 (2007). 10.1016/j.sbi.2007.10.001 [DOI] [PubMed] [Google Scholar]
- Wylie B. J., Sperling L. J., Nieuwkoop A. J., Franks W. T., Oldfield E., and Rienstra C. M., Proc. Natl. Acad. Sci. U.S.A. 108, 16974 (2011). 10.1073/pnas.1103728108 [DOI] [PMC free article] [PubMed] [Google Scholar]
- Czinki E., Csaszar A. G., Magyarfalvi G., Schreiner P. R., and Allen W. D., J. Am. Chem. Soc. 129, 1568 (2007). 10.1021/ja065461k [DOI] [PubMed] [Google Scholar]
- Yarimagaev Y., Tutunjian P. N., and Waugh J. S., J. Magn. Reson. 47, 51 (1982). 10.1016/0022-2364(82)90320-1 [DOI] [Google Scholar]
- Gullion T., J. Magn. Reson. 85, 614 (1989). 10.1016/0022-2364(89)90253-9 [DOI] [Google Scholar]
- Tycko R., Dabbagh G., and Mirau P. A., J. Magn. Reson. 85, 265 (1989). 10.1016/0022-2364(89)90142-X [DOI] [Google Scholar]
- Frydman L., Chingas G. C., Lee Y. K., Grandinetti P. J., Eastman M. A., Barrall G. A., and Pines A., J. Chem. Phys. 97, 4800 (1992). 10.1063/1.463860 [DOI] [Google Scholar]
- Gan Z. H., J. Am. Chem. Soc. 114, 8307 (1992). 10.1021/ja00047a062 [DOI] [Google Scholar]
- Hu J. Z., Orendt A. M., Alderman D. W., Pugmire R. J., Ye C. H., and Grant D. M., Solid State Nucl. Magn. Reson. 3, 181 (1994). 10.1016/0926-2040(94)90039-6 [DOI] [PubMed] [Google Scholar]
- Antzutkin O. N., Shekar S. C., and Levitt M. H., J. Magn. Reson., Ser. A 115, 7 (1995). 10.1006/jmra.1995.1142 [DOI] [Google Scholar]
- Hu J. Z., Wang W., Liu F., Solum M. S., Alderman D. W., Pugmire R. J., and Grant D. M., J. Magn. Reson., Ser A 113, 210 (1995). 10.1006/jmra.1995.1082 [DOI] [Google Scholar]
- Crockford C., Geen H., and Titman J. J., Chem. Phys. Lett. 344, 367 (2001). 10.1016/S0009-2614(01)00820-X [DOI] [Google Scholar]
- Liu S. F., Mao J. D., and Schmidt-Rohr K., J. Magn. Reson. 155, 15 (2002). 10.1006/jmre.2002.2503 [DOI] [PubMed] [Google Scholar]
- Chan J. C. C. and Tycko R., J. Chem. Phys. 118, 8378 (2003). 10.1063/1.1565109 [DOI] [Google Scholar]
- Elena B., Hediger S., and Emsley L., J. Magn. Reson. 160, 40 (2003). 10.1016/S1090-7807(02)00037-X [DOI] [PubMed] [Google Scholar]
- Shao L. M., Crockford C., Geen H., Grasso G., and Titman J. J., J. Magn. Reson. 167, 75 (2004). 10.1016/j.jmr.2003.11.005 [DOI] [PubMed] [Google Scholar]
- Strohmeier M. and Grant D. M., J. Magn. Reson. 168, 296 (2004). 10.1016/j.jmr.2004.03.003 [DOI] [PubMed] [Google Scholar]
- Kiihne S. R., Creemers A. F. L., Lugtenburg J., and de Groot H. J. M., J. Magn. Reson. 172, 1 (2005). 10.1016/j.jmr.2004.09.001 [DOI] [PubMed] [Google Scholar]
- Nishiyama Y., Yamazaki T., and Terao T., J. Chem. Phys. 124, 064304 (2006). 10.1063/1.2141949 [DOI] [PubMed] [Google Scholar]
- Orr R. M. and Duer M. J., Solid State Nucl. Magn. Reson. 30, 1 (2006). 10.1016/j.ssnmr.2005.12.001 [DOI] [PubMed] [Google Scholar]
- Hung I. and Gan Z. H., J. Magn. Reson. 213, 196 (2011). 10.1016/j.jmr.2011.09.015 [DOI] [PubMed] [Google Scholar]
- Eden M. and Levitt M. H., J. Chem. Phys. 111, 1511 (1999). 10.1063/1.479410 [DOI] [Google Scholar]
- Carravetta M., Eden M., Zhao X., Brinkmann A., and Levitt M. H., Chem. Phys. Lett. 321, 205 (2000). 10.1016/S0009-2614(00)00340-7 [DOI] [Google Scholar]
- Brinkmann A. and Levitt M. H., J. Chem. Phys. 115, 357 (2001). 10.1063/1.1377031 [DOI] [Google Scholar]
- Levitt M. H., in Encyclopedia of Nuclear Magnetic Resonance, edited by Grant D. M. and Harris R. K. (Wiley, Chichester, 2002), pp. 165. [Google Scholar]
- Hou G., Paramasivam S., Byeon I. J. L., Gronenborn A. M., and Polenova T., Phys. Chem. Chem. Phys. 12, 14873 (2010). 10.1039/c0cp00795a [DOI] [PMC free article] [PubMed] [Google Scholar]
- Han Y., Ahn J., Concel J., Byeon I. J., Gronenborn A. M., Yang J., and Polenova T., J. Am. Chem. Soc. 132, 1976 (2010). 10.1021/ja908687k [DOI] [PMC free article] [PubMed] [Google Scholar]
- Hou G. J., Byeon I. J. L., Ahn J., Gronenborn A. M., and Polenova T., J. Am. Chem. Soc. 133, 18646 (2011). 10.1021/ja203771a [DOI] [PMC free article] [PubMed] [Google Scholar]
- Neue G. and Dybowski C., Solid State Nucl. Magn. Reson. 7, 333 (1997). 10.1016/S0926-2040(96)01291-X [DOI] [PubMed] [Google Scholar]
- Zhao X., Eden M., and Levitt M. H., Chem. Phys. Lett. 342, 353 (2001). 10.1016/S0009-2614(01)00593-0 [DOI] [Google Scholar]
- Eden M., Chem. Phys. Lett. 378, 55 (2003). 10.1016/S0009-2614(03)01241-7 [DOI] [Google Scholar]
- Hou G. J. et al. , J. Am. Chem. Soc. 133, 3943 (2011). 10.1021/ja108650x [DOI] [PMC free article] [PubMed] [Google Scholar]
- Bak M., Rasmussen J. T., and Nielsen N. C., J. Magn. Reson. 147, 296 (2000). 10.1006/jmre.2000.2179 [DOI] [PubMed] [Google Scholar]
- Cheng V. B., Suzukawa H. H., and Wolfsber M., J. Chem. Phys. 59, 3992 (1973). 10.1063/1.1680590 [DOI] [Google Scholar]
- See supplementary material at http://dx.doi.org/10.1063/1.4754149 for additional figures and tables.
- Schanda P., Meier B. H., and Ernst M., J. Am. Chem. Soc. 132, 15957 (2010). 10.1021/ja100726a [DOI] [PubMed] [Google Scholar]
- Berthet-Colominas C., Monaco S., Novelli A., Sibai G., Mallet F., and Cusack S., EMBO J. 18, 1124 (1999). 10.1093/emboj/18.5.1124 [DOI] [PMC free article] [PubMed] [Google Scholar]
- Ternois F., Sticht J., Duquerroy S., Krausslich H. G., and Rey F. A., Nat. Struct. Mol. Biol. 12, 678 (2005). 10.1038/nsmb967 [DOI] [PubMed] [Google Scholar]
- Jiang J. et al. , Virology 421, 253 (2011). 10.1016/j.virol.2011.09.012 [DOI] [PMC free article] [PubMed] [Google Scholar]
- Byeon I. J. et al. , J. Am. Chem. Soc. 134, 6455 (2012). 10.1021/ja300937v [DOI] [PMC free article] [PubMed] [Google Scholar]
- Yang J., Tasayco M. L., and Polenova T., J. Am. Chem. Soc. 131, 13690 (2009). 10.1021/ja9037802 [DOI] [PMC free article] [PubMed] [Google Scholar]
- Weber P. L., Sieker L. C., Samy T. S. A., Reid B. R., and Drobny G. P., J. Am. Chem. Soc. 109, 5842 (1987). 10.1021/ja00253a042 [DOI] [Google Scholar]
- Buffy J. J., Waring A. J., Lehrer R. I., and Hong M., Biochemistry 42, 13725 (2003). 10.1021/bi035187w [DOI] [PubMed] [Google Scholar]