Abstract
Background: Rain and flooding from Hurricane Katrina resulted in widespread growth of mold and bacteria and production of allergens in New Orleans, Louisiana, which may have led to increased exposures and morbidity in children with asthma.
Objectives: The goal of the Head-off Environmental Asthma in Louisiana (HEAL) study was to characterize post-Katrina exposures to mold and allergens in children with asthma.
Methods: The homes of 182 children with asthma in New Orleans and surrounding parishes were evaluated by visual inspection, temperature and moisture measurements, and air and dust sampling. Air was collected using vacuum-pump spore traps and analyzed for > 30 mold taxa using bright field microscopy. Dust was collected from the children’s beds and bedroom floors and analyzed for mouse (Mus m 1), dust mite (Der p 1), cockroach (Bla g 1), and mold (Alternaria mix) allergens using ELISA.
Results: More than half (62%) of the children were living in homes that had been damaged by rain, flooding, or both. Geometric mean indoor and outdoor airborne mold levels were 501 and 3,958 spores/m3, respectively. Alternaria antigen was detected in dust from 98% of homes, with 58% having concentrations > 10 µg/g. Mus m 1, Der p 1, and Bla g 1 were detected in 60%, 35%, and 20% of homes, respectively, at low mean concentrations.
Conclusions: Except for Alternaria antigen in dust, concentrations of airborne mold (ratio of indoor to outdoor mold) and dust allergens in the homes of HEAL children were lower than measurements found in other studies, possibly because of extensive post-Katrina mold remediation and renovations, or because children moved into cleaner homes upon returning to New Orleans.
Keywords: allergens, asthma, endotoxin, environmental remediation, glucan, Hurricane Katrina, mold
On 29 August 2005, Hurricane Katrina struck the Gulf Coast, devastating much of the area in its path. The next day, many of the levees in Orleans Parish were breached, and 80% of the parish flooded; water levels rose to 20 feet in some areas (Kates et al. 2006). In addition, high winds caused roof damage, resulting in further water intrusion and moisture. The wet conditions provided an ideal environment for mold and bacterial growth in the city of New Orleans and surrounding parishes (NOLA). These organisms and their by-products (glucans, endotoxins) and allergens that are associated with moist environments (e.g., dust mite, cockroach) can exacerbate childhood asthma and allergies (Clark et al. 2004; Fisk et al. 2007; Jaakkola et al. 2005; Rosenbaum et al. 2010; Rosenstreich et al. 1997). However, the levels at which health effects occur and the factors associated with individual susceptibility to these outcomes are not well characterized (Brandt et al. 2006; Horner et al. 2008).
Several months after Katrina, many homes exhibited visible mold growth. In one study, 46% of 112 homes representing a random cross-section of homes in several NOLA parishes had visible mold growth (Ratard et al. 2006). In other studies, indoor airborne mold concentrations were higher than outdoor concentrations (Rao et al. 2007; Solomon et al. 2006). Indoor airborne mold concentrations were especially high in homes that had flooded (Chew et al. 2006), sometimes as much as five times higher than in homes that had not flooded (p < 0.05) (Solomon et al. 2006). The high mold concentrations were a concern for children with asthma returning to NOLA because associations between mold and asthma, wheeze, and other respiratory symptoms have been observed in other studies (Clark et al. 2004; Fisk et al. 2007; Jaakkola et al. 2005; Rockwell 2005; Rosenbaum et al. 2010). High concentrations of airborne endotoxin (Rao et al. 2007; Solomon et al. 2006) and glucan (Rao et al. 2007) were also reported in these post-Katrina studies at levels previously associated with respiratory pathology and decreased lung function (Douwes et al. 2002; Reynolds et al. 2001; Rylander et al. 1998).
HEAL was implemented to better understand the risk factors and needs of children with moderate-to-severe asthma in postdisaster settings such as post-Katrina NOLA. Its primary goals were to a) characterize post-Katrina environmental exposures; b) examine relationships between exposures, allergen sensitivities, and asthma morbidity; and c) implement a novel hybrid asthma counselor program that combined case management with tailored guidance for reducing allergens in the home (Chulada et al. 2012). Home environment evaluations were an important component of HEAL. Results from these evaluations were used to characterize post-Katrina environmental exposures in children with asthma as described above, tailor the asthma counselor intervention to the child’s sensitivity and exposure, and assess the effectiveness of the asthma counselor intervention at reducing allergens in the home. In this report, we describe the baseline environmental exposures (airborne mold and dust levels of allergens, endotoxin, and glucan) of HEAL children. These data are important in light of the dynamic nature of the post-Katrina environment, and will be instrumental in further analysis of the relationships between asthma, mold, and allergens in a postdisaster setting.
Methods
Participants. Eligibility criteria, recruitment methods, and characteristics of the 182 HEAL children have been described elsewhere (Chulada et al. 2012). Children were recruited based on having physician-diagnosed, moderate-to-severe asthma, as defined by the 2007 National Asthma Education and Prevention Program (National Heart Lung and Blood Institute 2007). Although more than half of HEAL children (62%) came from water-damaged homes, this was not a recruitment criterion. HEAL was approved by the National Institute of Environmental Health Sciences, Tulane University, and Louisiana State University institutional review boards; written informed consent was provided by each child’s caretaker or legal guardian, and children were asked for written or oral assent, depending on age.
Home environment evaluations. The homes of HEAL children were evaluated by teams of two trained environmental technicians. The evaluations lasted about 2.5 hr and consisted of a visual inspection, moisture and temperature measurements, a home survey with caregivers to collect residential and remediation histories, and environmental sample collection.
Visual inspections. Technicians followed a standardized protocol for conducting visual inspections that was modeled on the Inner-City Asthma Study (ICAS) (Crain et al. 2002) but modified for HEAL. The homes were inspected to determine the dwelling type and size, collect information on floor coverings and window treatments, and record the presence of dirty or greasy kitchen appliances, dehumidifiers, high-efficiency particulate air (HEPA) filtration units, animals, and odors [e.g., mustiness, tobacco smoke; formaldehyde if a FEMA (Federal Emergency Management Agency) trailer]. Homes were also inspected for signs of mold, moisture, water damage, roof leaks, smoking, open food containers, crumbs, pest infestation, and other sources of allergens and environmental hazards. The technicians focused on the living room, kitchen, child’s sleeping room, and child’s bathroom.
Moisture and temperature measurements. Indoor air temperature and relative humidity were measured as an indicator of dampness using a thermohygrometer pen (Fisher Scientific, Pittsburgh, PA). Outdoor temperature and humidity were also measured.
Home survey. The home surveys were based on instruments used in ICAS (Crain et al. 2002; Morgan et al. 2004) that were modified for HEAL. In the HEAL version, questions were added regarding the pre- and post-Katrina presence of mold and post-Katrina water damage and roof leaks, renovation (gutting walls, replacing floors and ceilings), and remediation for mold (scrubbing, treating or pressure washing walls or floors, replacing porous furnishings or heating, ventilation, and air conditioning systems).
Airborne mold sampling procedures. Indoor airborne mold samples were collected from the children’s bedrooms and living rooms using Zefon Air-O-Cell spore traps and battery-operated Zefon Bio-Pumps (Zefon International Inc., Ocala, FL). The spore trap and pump assembly was attached to a Bio-Pump tripod (Zefon International Inc.) and placed in the center of each room approximately 1.2 m above the floor. Duplicate air samples were collected from each room for 10 min at a flow rate of 15 L air/min. The time was based on Zefon recommendations for indoor sampling where no visible dust is evident. One outdoor airborne mold sample was collected approximately 6 m from the front door of the home using the same technique.
For the baseline dataset, one bedroom air sample and one outdoor air sample were analyzed at Air Quality Sciences (AQS) (Marietta, GA), an AIHA-EMLAP (American Industrial Hygiene Association–Environmental Microbiology Laboratory Accreditation Program) accredited laboratory, using bright field optical microscopy (Zeiss, Melrose, NY). The glass slips contained within the cassettes were removed, affixed onto regular glass microscope slides, and mounted in lactic acid with cotton blue. Particle deposit traces were located at a magnification of 100×. Large spores (≥ 7 μm) present on 100% of the deposit trace were identified and counted at a magnification of 400×. Small spores (< 7 μm) present on 25% of the deposit trace and spore types that were too numerous to count under 400× were identified and counted at a magnification of 1,000×. Spores were categorized by morphological groups following general taxonomic guidelines. The levels of total spores and specific spore types were expressed as spores per cubic meter of air.
Dust allergen collection and analysis. Dust was collected from the children’s beds and bedroom floors using Mitest collectors and filters (Indoor Biotechnologies, Charlottesville, VA) that were fitted onto the nozzle of a standard vacuum cleaner (Eureka Mighty Mite canister 3670G; Eureka, Peoria, IL) (Gruchalla et al. 2005). Technicians vacuumed a 1 m × 1 m square area of floor for 5 min. The Mitest collectors and filters were changed and the wand extension cleaned before the beds were vacuumed; dust was collected from the entire bed for 5 min.
Dust samples were analyzed at AQS. Bed dust was sieved using 50-mesh (300-μm openings) screens. An aqueous extract was prepared by adding 2 mL phosphate-buffered saline (PBS)/0.05% Tween 20 to 100 mg of sieved dust. Dust suspensions were mixed on a tube rotator (Multi-purpose rotator; Scientific Labs, Bohemia, NY) for 2 hr at room temperature and then clarified by centrifugation at 4°C, and the supernatants were frozen until use. If the quantity of bed dust was insufficient to make the extract, it was supplemented or replaced with bedroom floor dust.
Supernatants were analyzed for Der p 1 (dust mite), Bla g 1 (cockroach), and Mus m 1 (mouse) allergens using monoclonal antibody-based (or monoclonal/polyclonal for Bla g 1) enzyme-linked immunosorbent assays (ELISA) (Indoor Biotechnologies, Charlottesville, VA). Results were expressed as the mass of allergen per gram of dust, or as units per gram in the case of Bla g 1. Detection limits were 0.2 µg/g for Der p 1, 0.015 µg/g for Mus m 1, and 0.4 U/g for Bla g 1. Dust samples were also assayed for mold (Alternaria mix) by inhibition ELISA using polyclonal antibodies raised against a crude extract of Alternaria alternata (Greer Laboratories, Inc., Lenoir, NC). This assay had a detection limit of 0.3 µg/g (Salo et al. 2005). Previous cut-offs associated with increased allergic sensitization are used to establish “high” exposure levels for Bla g 1 (Eggleston et al. 1998), Der p 1 (Platts-Mills et al. 1992), and Mus m 1 (Phipatanakul et al. 2000). Although no standard cut-off has been proposed for Alternaria, data from the National Survey of Lead and Allergens in Housing showed that only 25% of U.S. homes have Alternaria > 10 µg/g (Salo et al. 2005).
Endotoxin and glucan analyses. Sieved bedroom dust was assayed for endotoxin and glucan by the laboratory of Peter Thorne, Environmental Health Sciences Research Center, University of Iowa (Blanc et al. 2005). Dust was suspended to concentrations of 50 mg/mL using pyrogen-free water containing 0.05% Tween 20 and shaken for 1 hr at room temperature. Samples were then centrifuged for 20 minutes at 600 × g at 4oC, and 0.1-mL aliquots of supernatant were removed to pyrogen-free cryovials for analysis.
Endotoxin was analyzed using the Limulus Amebocyte Lysate Kinetic-QCL Test Kit (BioWhittaker, Walkersville, MD). Standards were diluted in clean borosilicate glass tubes (heated > 2 hr at 200oC to remove endotoxin). Two-fold serial dilutions were prepared using pyrogen-free water containing 0.05% Tween 20. A 12-point calibration curve ranging from 0.05 to 100 EU endotoxin/mL gave a correlation of 0.997 to 0.998 based on the maximum change of optical density over time.
Glucan was extracted by adding 0.1 mL of 10× PBS to the supernatants from above. These were shaken for 1 hr at room temperature, autoclaved for 1 hr at 120oC, shaken for 15 minutes, and centrifuged at 600 × g for 20 min at 4oC. The concentration of fungal glucan in the eluates was quantified by sandwich ELISA using custom mouse anti-(1□3, 1□6)-β-d-glucan monoclonal antibody as the capture antibody and rabbit anti-scleroglucan polyclonal antibody as the detection antibody (Blanc et al. 2005).
Statistical methods. Log-transformations were used for all airborne mold analyses because the values were log-normally distributed. Results are presented as geometric means and standard deviations. Population-level differences between mold levels in flooded and nonflooded homes were compared using t-tests, and the relationship between mold level and flooding was examined in subgroups of interest using both between-group (interaction F-tests) and within-group (t-tests) differences. Unadjusted baseline correlations between exposures and home characteristics were calculated using Spearman correlations. Analyses were conducted using SAS version 9.2 (SAS Institute Inc., Cary, NC) and R version 2.13 (R Project for Statistical Computing, Vienna, Austria).
Results
Home surveys and visual inspection. Baseline home environmental evaluations occurred between 19 and 35 months post-Katrina (March 2007 through July 2008). A total of 182 homes were evaluated; the predominant type of dwelling was a single-family house (62%). Only nine of the dwellings (5%) were FEMA trailers (Table 1). Mold was visually detected in 21 (12%) of the homes, and a musty smell was detected in 7 (4%) of the children’s bedrooms. Thirty-two percent of the homes had pets (dog only, 23%; cat only, 6%; both, 3%). Problems with cockroaches were reported by caregivers in 40% of the homes, but visual signs of cockroaches were seen in only 16%. Average (± SD) temperature and relative humidity in the children’s bedrooms on the day of the baseline home evaluation were 75.2 ± 4.1oF and 51.9 ± 8.9%, respectively.
Table 1.
n (%) or mean ± SD | |
---|---|
Home characteristics (182 enrolled homes) | |
Katrina-related water damage to current home | |
Flooding only | 43 (24) |
Roof leak only | 45 (25) |
Flooding and roof leak | 25 (14) |
None | 69 (38) |
Current housing type | |
Single-family detached house | 112 (62) |
Multifamily house (duplex/triplex/row house) | 39 (21) |
Apartment | 15 (8) |
FEMA trailer | 9 (5) |
Other | 7 (4) |
Visible mold in the homea | 21 (12) |
Musty smell in child’s bedroom | 7 (4) |
Pets | |
Dog | 41 (23) |
Cat | 11 (6) |
Both | 5 (3) |
Evidence of cockroaches in the home | |
Reported | 72 (40) |
Observed | 29 (16) |
Temperature (°F) and relative humidity (%) | |
Bedroom temperature | 75.2 ± 4.1 |
Outdoor temperature | 81.5 ± 11.3 |
Bedroom relative humidity | 51.9 ± 8.9 |
Outdoor relative humidity | 55.1 ± 17.1 |
Renovation and remediation of flooded homes before baseline | |
Renovation status of 68 flooded homes at baseline | |
Completed | 41 (60) |
Ongoing | 18 (26) |
Not started | 9 (13) |
Types of renovation completed (22 homes)b | |
Gutted walls | 17 (77) |
Replaced ceilings | 16 (73) |
Replaced flooring | 20 (91) |
Mold remediation completed (22 homes) | 20 (91) |
Types of mold remediation completed (20 homes) | |
Scrubbed, treated, or pressure-washed walls | 5 (25) |
Scrubbed, treated, or pressure-washed studs | 10 (50) |
Scrubbed, treated, or pressure-washed floors | 7 (35) |
Replaced porous furnishings | 20 (100) |
Replaced heating/cooling system | 15 (75) |
Cleaned vents/ducts | 14 (70) |
aInformation available for 179 homes only. bDetails about the types of renovation and mold remediation that occurred were collected for 22 of 41 homes that had renovations completed before HEAL enrollment; 20 of these 22 homes also completed mold-specific remediation. |
More than half of the participants (63%) were living in homes that had been water-damaged after Katrina (Table 1); 24% had flood damage only, 25% had roof leaks only, and 14% had both. Of the 68 homes that flooded, 41 had completed renovations and mold remediation before HEAL baseline evaluations were conducted, and details about the steps taken were available for 22 of the 41 homes (Table 1).
Dust allergens. Alternaria antigen was detected in dust from 98% of the bedrooms (Table 2) with a median concentration of 13.7 µg/g. The majority of the bedrooms (58%) had Alternaria antigen concentrations ≥ 10 µg/g. Mus m 1 (mouse) allergen was the next most prevalent allergen (detected in 60% of bedrooms), with high concentrations (≥ 1.6 µg/g) detected in 3% of the bedrooms. Bla g 1 (cockroach) allergen was detected in 20% of bedrooms, with 4% having high concentrations (≥ 2 U/g). Der p 1 (dust mite) allergen was detected in 35% of bedrooms, with 9% having high concentrations (≥ 2 µg/g).
Table 2.
Geometric mean (GSE) | n (%) detectablea | n (%) highb | ||||
---|---|---|---|---|---|---|
Bedroom dust–allergen levels (181 homes) | ||||||
Alternaria (µg/g) | 11.3 (1.1) | 178 (98) | 105 (58) | |||
Cockroach [Bla g 1 (U/g)] | 0.30 (0.02) | 37 (20) | 8 (4) | |||
Dust mite [Der p 1 (µg/g)] | 0.22 (0.02) | 63 (35) | 16 (9) | |||
Mouse [Mus m 1 (µg/g)] | 0.04 (0.01) | 108 (60) | 5 (3) | |||
Bedroom dust–microbial components (181 homes) | ||||||
β-glucan (µg/g) | 0.50 (0.06) | |||||
Endotoxin (EU/mg) | 11.4 (1.5) | |||||
Mold air sampling (182 homes) | ||||||
Indoor total (spores/m3) | 501 (48) | |||||
Outdoor total (spores/m3) | 3,958 (467) | |||||
aDetection limits were 0.4 U/g for Bla g 1, 0.2 µg/g for Der p 1, 0.015 µg/g for Mus m 1, and 0.3 µg/g for Alternaria. bHigh levels were above 2 U/g for Bla g 1, 2 µg/g for Der p 1, 1.6 µg/g for Mus m 1, and 10 µg/g Alternaria. |
Airborne mold. Geometric mean airborne mold levels were found to be lower indoors than outdoors (501 spores/m3 indoors and 3,859 spores/m3 outdoors) (Table 2). There was no obvious time trend in indoor or outdoor airborne mold levels during HEAL [see Supplemental Material, Figure S1 (http://dx.doi.org/10.1289/ehp.1104840)]. A small increase in indoor and outdoor levels was observed in the fall (September, October, and November) of 2007, but differences between fall and non-fall months were not significant (p = 0.25 for indoor; p = 0.89 for outdoor).
Mold spore taxa in indoor and outdoor air, ranked by prevalence, are presented in Table 3. Molds commonly found in leaf surface/outdoor taxa (e.g., Basidiospores, 98%; Cladosporium, 97%; Ascospores, 92%) were detected most frequently indoor and reflected what was detected outdoors and molds associated with severe water damage (e.g., Ulocladium, 18%; Chaeromium, 15%; Stachybotrys, 3%) were not as commonly detected indoors and also reflected what was detected outdoors.
Table 3.
Rank | Indoor molds | Geometric mean (GSE) | Outdoor molds | Geometric mean (GSD) | ||
---|---|---|---|---|---|---|
Mold type | n (%) detectable | Mold type | n (%) detectable | |||
1st | Basidiospores | 179 (98) | 143 (17.8) | Basidiospores | 181 (99) | 1,311 (202.7) |
2nd | Cladosporium | 176 (97) | 64 (7.5) | Cladosporium | 181 (99) | 481 (60.4) |
3rd | Ascospores | 167 (92) | 32 (3.6) | Ascospores | 181 (99) | 251(29.4) |
4th | Penicillium–Aspergillus | 142 (78) | 17 (2.5) | Penicillium–Aspergillus | 133 (73) | 19 (2.9) |
5th | Curvularia | 140 (77) | 13 (1.6) | Ganoderma | 134 (74) | 14 (2.1) |
6th | Unidentified | 111 (61) | 5 (0.6) | Curvularia | 122 (67) | 11 (1.7) |
7th | Bipolaris | 106 (58) | 5 (0.6) | Unidentified | 117 (64) | 8 (1.2) |
8th | Pithomyces | 100 (55) | 5 (0.6) | Cercospora | 114 (63) | 7 (0.9) |
9th | Alternaria | 72 (40) | 3 (0.3) | Alternaria | 118 (65) | 7 (0.8) |
10th | Ganoderma | 60 (33) | 2 (0.2) | Bipolaris | 108 (59) | 5 (0.7) |
11th | Epicoccum | 51 (28) | 2 (0.2) | Epicoccum | 82 (45) | 3 (0.4) |
12th | Ulocladium | 32 (18) | 2 (0.1) | Pithomyces | 67 (37) | 3 (0.3) |
13th | Chaetomium | 27 (15) | 1 (0.1) | Pestalotia | 42 (23) | 2 (0.1) |
14th | Arthrinium | 17 (9) | 1 (0.1) | Arthrinium | 13 (7) | 1 (0.08) |
15th | Cercospora | 23 (13) | 1 (0.1) | Chaetomium | 17 (9) | 1 (0.09) |
16th | Pestalotia | 20 (11) | 1 (0.1) | Stachybotrys | 8 (4) | 1 (0.06) |
17th | Stemphylium | 8 (4) | 1 (0.04) | Ulocladium | 9 (5) | 1 (0.04) |
18th | Stachybotrys | 6 (3) | 1 (0.03) | Stemphylium | 9 (5) | 1 (0.04) |
19th | Trichoderma | 1 (1) | 1 (0.03) | Rust | 5 (3) | 1 (0.03) |
20th | Rust | 2 (1) | 1 (0.02) | Trichoderma | 1 (1) | 1 (0.02) |
21st | Other | 0 (0) | 0 (0) | Other | 0 (0) | 0 (0) |
Flooded versus nonflooded homes. Flooded homes (n = 68) had marginally higher levels of airborne mold than non-flooded homes (n = 114) [627 vs. 438 spores/m3 for indoor, p = 0.07 (Table 4); 4,954 vs. 3,462 for outdoor, p = 0.15]. Flooded homes also had higher levels of indoor airborne mold compared with nonflooded homes when children lived in the same homes during Katrina and at HEAL baseline (p = 0.02). Homes that were flooded and also had roof leaks had higher mold levels (742 spores/m3) than homes that had roof leaks only or that did not flood or have a roof leak (438 spores/m3 for both, p = 0.15 and 0.05, respectively). Mold spore levels were consistently higher in flooded versus nonflooded homes, though the differences were not statistically significant. As seen with the total population, the geometric mean airborne mold levels were found to be lower indoors than outdoors for both flooded and nonflooded homes. Also as seen with the total population, molds commonly found in leaf surface/outdoor taxa (e.g., Basidiospores, Cladosporium, Ascospores) were detected most frequently indoors and out, whereas molds associated with water damage (e.g., Ulocladium, Chaeromium, Stachybotrys) were not commonly found indoors and outdoors and were distributed similarly in flooded and nonflooded homes [see Supplemental Material, Tables S1 and S2 (http://dx.doi.org/10.1289/ehp.1104840)]. Allergen concentrations measured in bedroom dust (Alternaria antigen, Der p 1, Mus m 1, and Bla g 1) did not differ between flooded and nonflooded homes (all p > 0.30, data not shown).
Table 4.
Flooded | Not flooded | p-Valuea | ||||||||
---|---|---|---|---|---|---|---|---|---|---|
n | Level | n | Level | |||||||
All participants | 68 | 627 | 114 | 438 | 0.07 | |||||
Current home is same home child lived in during Katrina | ||||||||||
Yes | 36 | 679 | 56 | 359 | 0.02 | |||||
No | 32 | 573 | 58 | 531 | 0.79 | |||||
Current home, renovated after Katrina | ||||||||||
Yes | 41 | 587 | 44 | 445 | 0.29 | |||||
No | 27 | 693 | 70 | 434 | 0.14 | |||||
Current home, had roof leak during Katrina | ||||||||||
Yes | 25 | 742 | 45 | 438 | 0.15 | |||||
No | 43 | 568 | 69 | 438 | 0.27 | |||||
Current home residence typeb | ||||||||||
Single-family | 49 | 613 | 63 | 375 | 0.05 | |||||
Multifamily | 13 | 799 | 26 | 557 | 0.40 | |||||
Apartment | 4 | 380 | 11 | 365 | 0.96 | |||||
FEMA trailer | 0 | — | 9 | 711 | — | |||||
Values are geometric means in spores per cubic meter. ap-Values test for differences between homes that were flooded and not flooded. Interaction p-values between the flood status and the given strata were not statistically significant (all p > 0.10). bSingle-family refers to a detached house or non-FEMA trailer; multifamily refers to a duplex, triplex, or row house. |
The 41 homes that flooded but were completely renovated before the baseline evaluation had indoor mold levels of 587 spores/m3, compared with 693 spores/m3 for the 27 homes that flooded but were not completely renovated by baseline (p = 0.63, Table 3). Of the 27 flooded homes that had not been completely renovated by baseline, 14 had renovations that were completed during the course of the study. The changes in airborne mold levels from baseline to 12 months in these 14 homes (406 to 235 spores/m3) were not significantly different than the changes observed in the 6 homes that remained unrenovated or had incomplete renovations (1,312 to 327 spores/m3, comparison p = 0.35). Seven of the 27 flooded homes did not have 12-month evaluations.
Correlations between exposures and baseline home conditions. A small correlation was observed between indoor airborne mold levels and bedroom relative humidity (r = 0.22, p = 0.003) (Table 5). A correlation was observed between β-d-glucan and Alternaria antigen concentrations (r = 0.26, p = 0.006) (Table 5). An inverse correlation was observed between airborne bedroom mold and Alternaria allergen levels in bedroom dust (r = –0.16, p = 0.04).
Table 5.
Correlations (r-values) | Indoor air mold (n = 182) | Outdoor air mold (n = 182) | Alternaria (dust) (n = 181) | β-d-glucan (n = 109) | Endotoxin (n = 140) | ||
---|---|---|---|---|---|---|---|
Indoor mold | — | ||||||
Outdoor mold | 0.40** | — | |||||
Alternaria (bedroom dust) | –0.16** | 0.00 | — | ||||
β-d-glucan | 0.01 | –0.09 | 0.26** | — | |||
Endotoxin | 0.09 | 0.09 | 0.04 | 0.34* | — | ||
Flood level (feet) | –0.14 | –0.03 | 0.06 | 0.18 | –0.04 | ||
Bedroom relative humidity | 0.22** | 0.19** | –0.09 | 0.02 | –0.03 | ||
Outdoor relative humidity | 0.06 | 0.24** | –0.21** | –0.18* | –0.04 | ||
Bedroom temperature | 0.13* | 0.13* | –0.20* | 0.04 | 0.16* | ||
Outdoor temperature | 0.15** | 0.18** | –0.28* | –0.09 | 0.11 | ||
*0.05 < p < 0.1. **p < 0.05. |
Discussion
Many children with asthma have underlying allergies (Burrows et al. 1989; Remes and Korppi 1996; von Mutius et al. 1994), and for these children, indoor environmental allergens can exacerbate their symptoms. This is especially true in water-damaged areas such as post-Katrina NOLA, where concentrations of mold and other indoor allergens, including those that increase in moist environments such as dust mite, cockroach, and endotoxin, can reach high levels. In the months after Katrina, the concentrations of airborne mold, glucan, and endotoxin (Chew et al. 2006; Rao et al. 2007; Solomon et al. 2006) were of concern because they had reached levels previously associated with respiratory pathology, wheeze, and asthma in other studies (Douwes et al. 2002; Reynolds et al. 2001; Rockwell 2005; Rylander et al. 1998).
A major goal of HEAL was to characterize the post-Katrina environmental exposures of children with asthma. Therefore, we evaluated HEAL children’s homes for mold, allergens, and other asthma triggers at study baseline. Airborne mold levels vary over short periods of time, and cut-offs for normal mold exposure levels and levels associated with symptoms are not well established (Horner et al. 2008). Instead, characterization of potential mold exposure problems in a home is determined by the type of mold present (e.g., water-associated molds and soil mold spores rarely dominate in houses free of visible mold or water damage) and the ratio of indoor to outdoor mold (e.g., indoor is expected to be lower than outdoor levels) (Horner et al. 2008). When looking at the types of spores detected from HEAL samples, mold found indoors reflected what was detected outdoors; molds associated with water damage (e.g., Stachybotrys, Chaetomium, Ulocladium) were uncommon (3–18% of homes) and the most common molds were leaf surface/outdoor molds (e.g., Ascospores, Cladosporium, Basidiospores in 92–98% of homes). We found the average levels of indoor airborne mold to be lower than outdoor airborne mold, even for HEAL homes that had been flooded (geometric means of 627 indoor/4,954 outdoor spores/m3), in contrast with measurements taken within 2 months (11,000–645,000 indoor/21,000–102,000 outdoor spores/m3) (Solomon et al. 2006) and 1 month (356,000 indoor/43,000 outdoor spores/m3) (Rao et al. 2007) after Katrina.
These levels detected in HEAL compared with the other post-Katrina studies might not only reflect a difference in when the samples were collected and the state of the homes they were collected from, but may also reflect sampling time variability [10 min vs. 36–144 min (Rao et al. 2007) and 6–24 hr (Solomon et al. 2006)]. Other limitations in HEAL air sampling were the limited number of samples collected (i.e., two from each room), sample collection on a single day at a single point in time, and use of the Air-O-Cell/light microscopy method for mold identification. Previous research suggests that use of the Air-O-Cell/light microscopy method in combination with culturable mold identification, such as that used with the Andersen sampler, might provide a more representative indication of indoor mold levels and types (Heinsohn 2007; Tsai et al. 1999). The levels found in HEAL might also be a result, in part, of a natural reduction of mold and allergens as flood waters receded and debris piles were removed. They might also have been attributable to extensive home renovation and mold remediation measures conducted by NOLA residents after the storm. Renovation and mold remediation can be effective at reducing mold. In a demonstration project conducted shortly after Katrina, marked reductions in indoor airborne mold levels were observed in postrenovation homes compared with prerenovation homes, sometimes of multiple orders of magnitude (Chew et al. 2006). Similar reductions were observed in another study of 17 homes in the greater Kansas City, Missouri, area that underwent renovation/remediation because of visible mold and health concerns (Barnes et al. 2007). At HEAL baseline, a significant portion of HEAL children (n = 68) were living in homes that had flooded post-Katrina. Of these, 41 homes had completed renovation or mold remediation before HEAL baseline. Unfortunately, only 22 of the 41 caregivers in these homes were able to provide us with detailed information about the specific measures taken (Table 1), which was not enough data for a detailed analysis.
Another finding in HEAL was that flooded homes, regardless of renovation and remediation, had higher levels of indoor airborne mold than nonflooded homes. Although this finding was of borderline statistical significance (p = 0.07), the pattern persisted across several subsets of the study population. For example, airborne mold levels were higher in single-family homes that had flooded than in nonflooded single-family homes (p = 0.05) and when the child lived in the same home during Katrina that he or she lived in at HEAL baseline (p = 0.02). Living in a different location (instead of the same location) may be an indication that the home was new and therefore clean; however, we did not ask how old the home was. Homes that were both flooded and rain-damaged had some of the highest mold levels observed in the study (742 spores/m3), and these levels were significantly higher than in homes that sustained no water damage by flooding or a roof leak (438 spores/m3, p = 0.05; p-value not shown in Table 4). It would be informative to monitor indoor mold levels in these and other water-damaged homes over longer periods of time and to conduct a detailed analysis to examine relationships between mold levels and specific remediation measures.
Another interesting finding in HEAL was that although indoor airborne mold levels were lower than outdoor levels and substantially lower than what had been found within 2 months after Hurricane Katrina, Alternaria antigen was prevalent in dust samples collected from the children’s bedrooms; it was detected in almost all (98%) bedrooms and in 58% of bedrooms at concentrations > 10 µg/g. This relationship was unexpected and requires further investigation. Alternaria is a common fungus, and at high exposure levels, it has been associated with the onset of childhood asthma and with severe asthma reactions in sensitive individuals (Bush and Prochnau 2004; Downs et al. 2001; Lemanske 2002; Salo et al. 2005). Alternaria, like most molds, grows in humid areas and has been found in water-damaged homes, especially those that have cellulose in their building materials (Ren et al. 1998) (e.g., wood, insulation, ceiling tiles). Whether Alternaria was a significant asthma trigger in HEAL will require further investigation. It is possible that the high prevalence and concentration of Alternaria in HEAL bedroom dust samples were artifacts of the assay technique. Other fungi, such as those belonging to the Pleosporaceae family (Alternaria, Ulocladium, Stemphylium) and other dematiaceous genera including Epicoccum, can cross-react with the polyclonal antibody used in the Alternaria inhibition ELISA assay and artificially increase the results (Schmechel et al. 2008); these fungi were detected in HEAL air samples. Polymerase chain reaction analyses of HEAL dust (Vesper et al. 2007a, 2007b) will provide us with a more comprehensive mold profile. These results will be important in relating mold species to asthma morbidity as comparative genomic studies have indicated that certain allergens (Alt a 1, for example) may be shared between different species of fungi (Bowyer et al. 2006; Saenz-de-Santamaria et al. 2006).
Compared with Alternaria, other allergens (Bla g 1, Der p 1, and Mus m 1) were less abundant in dust samples (Table 2). Another post-Katrina study conducted at about the same time as HEAL also found low dust mite allergen levels; Der p 1 was detected from 14.7% of homes (1.6–18.7 μg/g from 3 of 7 occupied flooded homes and 2 of 27 unoccupied flooded homes) (Adhikari et al. 2010), compared with 35% of homes with detectable Der p 1 in HEAL (0.20–18.5 μg/g from 181 homes). This is in contrast with concentrations reported by the New Orleans Healthy Home Initiative (HHI), which was conducted several months before Katrina (Rabito et al. 2007), where Der p 1 exceeded 2 μg/g in 63.9% of homes compared with 9% of HEAL homes exceeding this level. Cockroach allergens detected in dust samples were also higher in HHI than in HEAL (Bla g 1 > 2U/g in 90.3% of homes in HHI vs. 4% in HEAL) (Rabito et al. 2007). The low concentrations in HEAL bedrooms might have been attributable partly to renovations and mold remediation or to children moving to new, cleaner homes. Environmental sampling techniques also might have contributed to the differences in allergen concentrations. In HEAL, dust from the children’s beds and bedroom floors was analyzed, whereas in HHI, dust was collected from the living room floor and upholstery, child’s bedroom floor and bed, and kitchen floor, and the highest value for the home from any of these locations was reported.
Similar to airborne concentrations of mold, geometric mean levels of dust-borne endotoxin and glucan in HEAL homes were low compared with other environmental studies (11.4 EU/mg in HEAL vs. 20 and 44 EU/mg endotoxin) (Park et al. 2000; Thorne et al. 2009), (0.5 μg/g in HEAL vs. 2,743 μg/g (1□3)-β-glucan and 55.1 μg/g (1□3)-β-d-glucan) (Bertelsen et al. 2010; Iossifova et al. 2007). However, the concentrations of endotoxin in HEAL are still of concern because they have previously been associated with increased asthma symptoms and use of asthma medications (Rizzo et al. 1997).
When we tested for correlations between mold, indoor allergens, and other home environment conditions, we found that the negative correlation between indoor airborne mold and dust Alternaria antigen concentrations described above was significant (p = 0.04). This result was unexpected and requires further investigation. Other correlations were as expected, such as the correlations between dust glucan and Alternaria antigen concentrations and between indoor airborne mold levels and bedroom relative humidity.
Conclusion
Before HEAL, flood waters had receded, most of the debris piles had been removed, and mold levels were decreasing naturally on their own. In addition, steps taken through public awareness programs to ensure that no one was living in mold-ridden homes seemed to be effective because no HEAL children were found living in unhealthy conditions from copious amounts of mold growing throughout a room or home. Although we found only low-to-moderate concentrations of airborne mold and dust allergens, the levels of certain exposures (endotoxin, Alternaria antigen) had previously been associated with increased asthma morbidity.
Supplemental Material
Footnotes
This project has been funded, in whole or in part, with federal funds from the National Institute of Environmental Health Sciences (NIEHS), National Institutes of Health (NIH), under contract NO1-ES-55553. Additional funding support was provided by the Merck Childhood Asthma Network and the National Center on Minority Health and Health Disparities under the auspices of the Foundation for the NIH, a nonprofit, 501(c)(3) charitable organization that raises private-sector funds for a broad portfolio of unique programs that complement and enhance the NIH priorities and activities. Other organizations that contributed include the National Toxicology Program (NIEHS), the U.S. Environmental Protection Agency (Cincinnati, OH), and the de Laski Family Foundation. The Clinical and Translational Research Center of Tulane and Louisiana State Universities Schools of Medicine was supported in whole or in part by funds provided through the Louisiana Board of Regents RC/EEP. H.M., J.W., and S.K. are employed by Rho Federal Systems Division, Inc. R.D.C. is employed by SRA International, Inc. E.T. is employed by Visionary Consulting Partners, LLC.
The authors declare they have no actual or potential competing financial interests.
References
- Adhikari A, Lewis JS, Reponen T, Degrasse EC, Grimsley LF, Chew GL, et al. Exposure matrices of endotoxin, (1□3)-β-d-glucan, fungi, and dust mite allergens in flood-affected homes of New Orleans. Sci Total Environ. 2010;408(22):5489–5498. doi: 10.1016/j.scitotenv.2010.07.087. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Barnes CS, Dowling P, Van Osdol T, Portnoy J. Comparison of indoor fungal spore levels before and after professional home remediation. Ann Allergy Asthma Immunol. 2007;98(3):262–268. doi: 10.1016/S1081-1206(10)60716-8. [DOI] [PubMed] [Google Scholar]
- Bertelsen RJ, Carlsen KC, Carlsen KH, Granum B, Doekes G, Haland G, et al. Childhood asthma and early life exposure to indoor allergens, endotoxin and beta(1,3)-glucans. Clin Exp Allergy. 2010;40(2):307–316. doi: 10.1111/j.1365-2222.2009.03424.x. [DOI] [PubMed] [Google Scholar]
- Blanc PD, Eisner MD, Katz PP, Yen IH, Archea C, Earnest G, et al. Impact of the home indoor environment on adult asthma and rhinitis. J Occup Environ Med. 2005;47(4):362–372. doi: 10.1097/01.jom.0000158708.32491.9d. [DOI] [PubMed] [Google Scholar]
- Bowyer P, Fraczek M, Denning DW. Comparative genomics of fungal allergens and epitopes shows widespread distribution of closely related allergen and epitope orthologues. BMC Genomics. 2006;7:251. doi: 10.1186/1471-2164-7-251. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Brandt M, Brown C, Burkhart J, Burton N, Cox-Ganser J, Damon S, et al. Mold prevention strategies and possible health effects in the aftermath of hurricanes and major floods. MMWR Recomm Rep. 2006;55(RR-8):1–27. [PubMed] [Google Scholar]
- Burrows B, Martinez FD, Halonen M, Barbee RA, Cline MG. Association of asthma with serum IgE levels and skin-test reactivity to allergens. N Engl J Med. 1989;320(5):271–277. doi: 10.1056/NEJM198902023200502. [DOI] [PubMed] [Google Scholar]
- Bush RK, Prochnau JJ. Alternaria-induced asthma. J Allergy Clin Immunol. 2004;113(2):227–234. doi: 10.1016/j.jaci.2003.11.023. [DOI] [PubMed] [Google Scholar]
- Chew GL, Wilson J, Rabito FA, Grimsley F, Iqbal S, Reponen T, et al. Mold and endotoxin levels in the aftermath of Hurricane Katrina: a pilot project of homes in New Orleans undergoing renovation. Environ Health Perspect. 2006;114:1883–1889. doi: 10.1289/ehp.9258. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Chulada PC, Kennedy S, Mvula MM, Jaffee K, Wildfire J, Thornton E, et al. The Head-off Environmental Asthma in Louisiana (HEAL) Study—methods and study population. Environ Health Perspect. 2012;120:1592–1599. doi: 10.1289/ehp.1104239. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Clark N, Fisk W, Nevalainen A. Washington, DC: National Academies Press; 2004. Damp Indoor Spaces and Health. [PubMed] [Google Scholar]
- Crain E, Walter M, O’Connor GT, Mitchell H, Gruchalla RS, Kattan M, et al. Home and allergic characteristics of children with asthma in seven U.S. urban communities and design of an environmental intervention: the Inner-City Asthma Study. Environ Health Perspect. 2002;110:939–945. doi: 10.1289/ehp.02110939. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Douwes J, Pearce N, Heederik D. Does environmental endotoxin exposure prevent asthma? Thorax. 2002;57(1):86–90. doi: 10.1136/thorax.57.1.86. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Downs SH, Mitakakis TZ, Marks GB, Car NG, Belousova EG, Leuppi JD, et al. Clinical importance of Alternaria exposure in children. Am J Respir Crit Care Med. 2001;164(3):455–459. doi: 10.1164/ajrccm.164.3.2008042. [DOI] [PubMed] [Google Scholar]
- Eggleston PA, Rosenstreich D, Lynn H, Gergen P, Baker D, Kattan M, et al. Relationship of indoor allergen exposure to skin test sensitivity in inner-city children with asthma. J Allergy Clin Immunol. 1998;102(4 pt 1):563–570. doi: 10.1016/s0091-6749(98)70272-6. [DOI] [PubMed] [Google Scholar]
- Fisk WJ, Lei-Gomez Q, Mendell MJ. Meta-analyses of the associations of respiratory health effects with dampness and mold in homes. Indoor Air. 2007;17(4):284–296. doi: 10.1111/j.1600-0668.2007.00475.x. [DOI] [PubMed] [Google Scholar]
- Gruchalla RS, Pongracic J, Plaut M, Evans R, III, Visness CM, Walter M, et al. Inner City Asthma Study: relationships among sensitivity, allergen exposure, and asthma morbidity. J Allergy Clin Immunol. 2005;115(3):478–485. doi: 10.1016/j.jaci.2004.12.006. [DOI] [PubMed] [Google Scholar]
- Heinsohn P. Hoboken, NJ: Wiley; 2007. Sampling And Analysis Of Indoor Microorganisms. [Google Scholar]
- Horner WE, Barnes C, Codina R, Levetin E. Guide for interpreting reports from inspections/investigations of indoor mold. J Allergy Clin Immunol. 2008;121(3):592–597 e597. doi: 10.1016/j.jaci.2007.11.020. [DOI] [PubMed] [Google Scholar]
- Iossifova YY, Reponen T, Bernstein DI, Levin L, Kalra H, Campo P, et al. House dust (1–3)-β-d-glucan and wheezing in infants. Allergy. 2007;62(5):504–513. doi: 10.1111/j.1398-9995.2007.01340.x. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Jaakkola JJ, Hwang BF, Jaakkola N. Home dampness and molds, parental atopy, and asthma in childhood: a six-year population-based cohort study. Environ Health Perspect. 2005;113:357–361. doi: 10.1289/ehp.7242. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Kates RW, Colten CE, Laska S, Leatherman SP. Reconstruction of New Orleans after Hurricane Katrina: a research perspective. Proc Natl Acad Sci USA. 2006;103(40):14653–14660. doi: 10.1073/pnas.0605726103. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Lemanske RF., Jr Issues in understanding pediatric asthma: epidemiology and genetics. J Allergy Clin Immunol. 2002;109(6(Suppl)):S521–S524. doi: 10.1067/mai.2002.124564. [DOI] [PubMed] [Google Scholar]
- Morgan WJ, Crain EF, Gruchalla RS, O’Connor GT, Kattan M, Evans R, III, et al. Results of a home-based environmental intervention among urban children with asthma. N Engl J Med. 2004;351(11):1068–1080. doi: 10.1056/NEJMoa032097. [DOI] [PubMed] [Google Scholar]
- National Heart, Lung, and Blood Institute. Expert Panel Report 3 (EPR-3): Guidelines for the Diagnosis and Management of Asthma–Full Report 2007. August 28, 2007. 2007. Available: www.nhlbi.nih.gov/guidelines/asthma/asthgdln.htm [accessed 1 December 2011]
- Park JH, Spiegelman DL, Burge HA, Gold DR, Chew GL, Milton DK. Longitudinal study of dust and airborne endotoxin in the home. Environ Health Perspect. 2000;108:1023–1028. doi: 10.1289/ehp.001081023. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Phipatanakul W, Eggleston PA, Wright EC, Wood RA. Mouse allergen. II. The relationship of mouse allergen exposure to mouse sensitization and asthma morbidity in inner-city children with asthma. J Allergy Clin Immunol. 2000;106(6):1075–1080. doi: 10.1067/mai.2000.110795. [DOI] [PubMed] [Google Scholar]
- Platts-Mills TA, Thomas WR, Aalberse RC, Vervloet D, Champman MD. Dust mite allergens and asthma: report of a second international workshop. J Allergy Clin Immunol. 1992;89(5):1046–1060. doi: 10.1016/0091-6749(92)90228-t. [DOI] [PubMed] [Google Scholar]
- Rabito FA, Iqbal S, Holt E, Grimsley LF, Islam TM, Scott SK. Prevalence of indoor allergen exposures among New Orleans children with asthma. J Urban Health. 2007;84(6):782–792. doi: 10.1007/s11524-007-9216-0. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Rao CY, Riggs MA, Chew GL, Muilenberg ML, Thorne PS, Van Sickle D, et al. Characterization of airborne molds, endotoxins, and glucans in homes in New Orleans after Hurricanes Katrina and Rita. Appl Environ Microbiol. 2007;73(5):1630–1634. doi: 10.1128/AEM.01973-06. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Ratard R, Brown C, Ferdinands J, Callahan D, Dunn K, Scalia M, et al. Health concerns associated with mold in water-damaged homes after Hurricanes Katrina and Rita–New Orleans area, Louisiana, October 2005. MMWR Morb Mortal Wkly Rep. 2006;55(2):41–44. [PubMed] [Google Scholar]
- Remes ST, Korppi M. Asthma and atopy in schoolchildren in a defined population. Acta Paediatr. 1996;85(8):965–970. doi: 10.1111/j.1651-2227.1996.tb14195.x. [DOI] [PubMed] [Google Scholar]
- Ren P, Ahearn DG, Crow SA., Jr Mycotoxins of Alternaria alternata produced on ceiling tiles. J Ind Microbiol Biotechnol. 1998;20(1):53–54. doi: 10.1038/sj.jim.2900477. [DOI] [PubMed] [Google Scholar]
- Reynolds S, Black DW, Borin SS, Breuer G, Burmeister LF, Fuortes LJ, et al. Indoor environmental quality in six commercial office buildings in the midwest United States. Appl Occup Environ Hyg. 2001;16(11):1065–1077. doi: 10.1080/104732201753214170. [DOI] [PubMed] [Google Scholar]
- Rizzo MC, Naspitz CK, Fernandez-Caldas E, Lockey RF, Mimica I, Sole D. Endotoxin exposure and symptoms in asthmatic children. Pediatr Allergy Immunol. 1997;8(3):121–126. doi: 10.1111/j.1399-3038.1997.tb00164.x. [DOI] [PubMed] [Google Scholar]
- Rockwell W. Prompt remediation of water intrusion corrects the resultant mold contamination in a home. Allergy Asthma Proc. 2005;26(4):316–318. [PubMed] [Google Scholar]
- Rosenbaum PF, Crawford JA, Anagnost SE, Wang CJ, Hunt A, Anbar RD, et al. Indoor airborne fungi and wheeze in the first year of life among a cohort of infants at risk for asthma. J Expo Sci Environ Epidemiol. 2010;20(6):503–515. doi: 10.1038/jes.2009.27. [DOI] [PubMed] [Google Scholar]
- Rosenstreich DL, Eggleston P, Kattan M, Baker D, Slavin RG, Gergen P, et al. The role of cockroach allergy and exposure to cockroach allergen in causing morbidity among inner-city children with asthma. N Engl J Med. 1997;336(19):1356–1363. doi: 10.1056/NEJM199705083361904. [DOI] [PubMed] [Google Scholar]
- Rylander R, Norrhall M, Engdahl U, Tunsater A, Holt PG. Airways inflammation, atopy, and (1□3)-β-d-glucan exposures in two schools. Am J Respir Crit Care Med. 1998;158(5 pt 1):1685–1687. doi: 10.1164/ajrccm.158.5.9712139. [DOI] [PubMed] [Google Scholar]
- Saenz-de-Santamaria M, Postigo I, Gutierrez-Rodriguez A, Cardona G, Guisantes JA, Asturias J, et al. The major allergen of Alternaria alternata (Alt a 1) is expressed in other members of the Pleosporaceae family. Mycoses. 2006;49(2):91–95. doi: 10.1111/j.1439-0507.2006.01195.x. [DOI] [PubMed] [Google Scholar]
- Salo PM, Yin M, Arbes SJ, Jr, Cohn RD, Sever M, Muilenberg M, et al. Dustborne Alternaria alternata antigens in US homes: results from the National Survey of Lead and Allergens in Housing. J Allergy Clin Immunol. 2005;116(3):623–629. doi: 10.1016/j.jaci.2005.05.030. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Schmechel D, Green BJ, Blachere FM, Janotka E, Beezhold DH. Analytical bias of cross-reactive polyclonal antibodies for environmental immunoassays of Alternaria alternata. J Allergy Clin Immunol. 2008;121(3):763–768. doi: 10.1016/j.jaci.2007.09.046. [DOI] [PubMed] [Google Scholar]
- Solomon GM, Hjelmroos-Koski M, Rotkin-Ellman M, Hammond SK. Airborne mold and endotoxin concentrations in New Orleans, Louisiana, after flooding, October through November 2005. Environ Health Perspect. 2006;114:1381–1386. doi: 10.1289/ehp.9198. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Thorne PS, Cohn RD, Mav D, Arbes SJ, Zeldin DC. Predictors of endotoxin levels in U.S. housing. Environ Health Perspect. 2009;117:763–771. doi: 10.1289/ehp.11759. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Tsai S, Yang C, Moffett P, Puccetti A. Albany, NY: Eastern New York Occupational and Environmental Health Center, 457–464; 1999. Comparative studies of collection efficiency of airborne fungal matter using Andersen single stage sampler and Air-O-Cell cassettes. In: Bioaerosols, Fungi, and Mycotoxins: Health Effects, Assessment, Prevention, and Control (Johanning E, ed) [Google Scholar]
- Vesper S, McKinstry C, Haugland RA, Iossifova Y, Lemasters G, Levin L, et al. Relative moldiness index as predictor of childhood respiratory illness. J Expo Sci Environ Epidemiol. 2007a;17(1):88–94. doi: 10.1038/sj.jes.7500528. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Vesper S, McKinstry C, Haugland R, Wymer L, Bradham K, Ashley P, et al. Development of an Environmental Relative Moldiness index for US homes. J Occup Environ Med. 2007b;49(8):829–833. doi: 10.1097/JOM.0b013e3181255e98. [DOI] [PubMed] [Google Scholar]
- von Mutius E, Martinez FD, Fritzsch C, Nicolai T, Roell G, Thiemann HH. Prevalence of asthma and atopy in two areas of West and East Germany. Am J Respir Crit Care Med. 1994;149(2pt 1):358–364. doi: 10.1164/ajrccm.149.2.8306030. [DOI] [PubMed] [Google Scholar]
Associated Data
This section collects any data citations, data availability statements, or supplementary materials included in this article.