Abstract
The CAPTIA Syphilis-G enzyme immunoassay for the detection of antibodies to Treponema pallidum was evaluated as a screening test for syphilis in comparison with the standard rapid plasma reagin (RPR) test. One thousand samples were tested, and the standard fluorescent treponemal antibody absorption test and the standard microhemmaglutination test were used to confirm the presence of treponemal antibodies. Diagnosis of syphilis was based on traditional standard serology results. Clinical data used in the diagnosis of patients whose samples yielded conflicting results were provided by physicians. Initially, 7 patients whose samples were reactive in the RPR test and 14 patients whose samples yielded positive or equivocal results in the CAPTIA Syphilis-G test were diagnosed as not being infected. After discrepancies due to technical problems were reconciled, samples from six patients remained reactive in the RPR test and that from one patient remained positive in the CAPTIA Syphilis-G test. In addition, seven patients whose samples were nonreactive in the RPR test and two patients whose samples were negative in the CAPTIA Syphilis-G test were diagnosed as having untreated syphilis. After discrepancies were reconciled, samples from five patients remained nonreactive in the RPR test and none remained negative in the CAPTIA Syphilis-G test. Final results indicate that the specificities are 99.4 and 99.9%, respectively. In addition to the improved sensitivity and specificity of the CAPTIA Syphilis-G screen, other potential benefits of this assay lead us to believe that this method could serve as a better screening tool than the RPR test.
Full text
PDFSelected References
These references are in PubMed. This may not be the complete list of references from this article.
- Anderson J., Mindel A., Tovey S. J., Williams P. Primary and secondary syphilis, 20 years' experience. 3: Diagnosis, treatment, and follow up. Genitourin Med. 1989 Aug;65(4):239–243. doi: 10.1136/sti.65.4.239. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Buchanan C. S., Haserick J. R. FTA-ABS test in pregnancy. A probable false-positive reaction. Arch Dermatol. 1970 Sep;102(3):322–325. [PubMed] [Google Scholar]
- Catterall R. D. Presidential Address to the M.S.S.V.D. Systemic disease and the biological false positive reaction. Br J Vener Dis. 1972 Feb;48(1):1–12. doi: 10.1136/sti.48.1.1. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Chen J., Lin T. M., Schubert C. M., Halbert S. P. Treponemal antibody-absorbent enzyme immunoassay for syphilis. J Clin Microbiol. 1986 May;23(5):876–880. doi: 10.1128/jcm.23.5.876-880.1986. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Dorwart B. B., Myers A. R. Comparison of rapid plasma reagin card test and venereal disease research laboratory test in the detection of biological false positive reactions in systemic lupus erythematosus. Br J Vener Dis. 1974 Dec;50(6):435–436. doi: 10.1136/sti.50.6.435. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Dyckman J. D., Storms S., Huber T. W. Reactivity of microhemagglutination, fluorescent treponemal antibody absorption, and venereal disease research laboratory tests in primary syphilis. J Clin Microbiol. 1980 Oct;12(4):629–630. doi: 10.1128/jcm.12.4.629-630.1980. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Farshy C. E., Hunter E. F., Helsel L. O., Larsen S. A. Four-step enzyme-linked immunosorbent assay for detection of Treponema pallidum antibody. J Clin Microbiol. 1985 Mar;21(3):387–389. doi: 10.1128/jcm.21.3.387-389.1985. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Farshy C. E., Hunter E. F., Larsen S. A., Cerny E. H. Double-conjugate enzyme-linked immunosorbent assay for immunoglobulins G and M against Treponema pallidum. J Clin Microbiol. 1984 Dec;20(6):1109–1113. doi: 10.1128/jcm.20.6.1109-1113.1984. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Hart G. Syphilis tests in diagnostic and therapeutic decision making. Ann Intern Med. 1986 Mar;104(3):368–376. doi: 10.7326/0003-4819-104-3-368. [DOI] [PubMed] [Google Scholar]
- Hook E. W., 3rd, Marra C. M. Acquired syphilis in adults. N Engl J Med. 1992 Apr 16;326(16):1060–1069. doi: 10.1056/NEJM199204163261606. [DOI] [PubMed] [Google Scholar]
- Kaufman R. E., Weiss S., Moore J. D., Falcone V., Wiesner P. J. Biological false positive serological tests for syphilis among drug addicts. Br J Vener Dis. 1974 Oct;50(5):350–353. doi: 10.1136/sti.50.5.350. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Larsen S. A., Hambie E. A., Pettit D. E., Perryman M. W., Kraus S. J. Specificity, sensitivity, and reproducibility among the fluorescent treponemal antibody-absorption test, the microhemagglutination assay for Treponema pallidum antibodies, and the hemagglutination treponemal test for syphilis. J Clin Microbiol. 1981 Oct;14(4):441–445. doi: 10.1128/jcm.14.4.441-445.1981. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Lefevre J. C., Bertrand M. A., Bauriaud R. Evaluation of the Captia enzyme immunoassays for detection of immunoglobulins G and M to Treponema pallidum in syphilis. J Clin Microbiol. 1990 Aug;28(8):1704–1707. doi: 10.1128/jcm.28.8.1704-1707.1990. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Manikowska-Lesińska W., Linda B., Zajac W. Specificity of the FTA-ABS and TPHA tests during pregnancy. Br J Vener Dis. 1978 Oct;54(5):295–298. doi: 10.1136/sti.54.5.295. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Nayar R., Campos J. M. Evaluation of the DCL Syphilis-G enzyme immunoassay test kit for the serologic diagnosis of syphilis. Am J Clin Pathol. 1993 Mar;99(3):282–285. doi: 10.1093/ajcp/99.3.282. [DOI] [PubMed] [Google Scholar]
- Peter C. R., Thompson M. A., Wilson D. L. False-positive reactions in the rapid plasma reagin-card, fluorescent treponemal antibody-absorbed, and hemagglutination treponemal syphilis serology tests. J Clin Microbiol. 1979 Mar;9(3):369–372. doi: 10.1128/jcm.9.3.369-372.1979. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Pope V., Hunter E. F., Feeley J. C. Evaluation of the microenzyme-linked immunosorbent assay with Treponema pallidum antigen. J Clin Microbiol. 1982 Apr;15(4):630–634. doi: 10.1128/jcm.15.4.630-634.1982. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Rolfs R. T., Goldberg M., Sharrar R. G. Risk factors for syphilis: cocaine use and prostitution. Am J Public Health. 1990 Jul;80(7):853–857. doi: 10.2105/ajph.80.7.853. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Thornton J. G., Foote G. A., Page C. E., Clayden A. D., Tovey L. A., Scott J. S. False positive results of tests for syphilis and outcome of pregnancy: a retrospective case-control study. Br Med J (Clin Res Ed) 1987 Aug 8;295(6594):355–356. doi: 10.1136/bmj.295.6594.355. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Veldkamp J., Visser A. M. Application of the enzyme-linked immunosorbent assay (ELISA) in the serodiagnosis of syphilis. Br J Vener Dis. 1975 Aug;51(4):227–231. doi: 10.1136/sti.51.4.227. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Wright J. T., Cremer A. W., Ridgway G. L. False positive FTA-ABS results in patients with genital herpes. Br J Vener Dis. 1975 Oct;51(5):329–330. doi: 10.1136/sti.51.5.329. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Young H., Moyes A., McMillan A., Patterson J. Enzyme immunoassay for anti-treponemal IgG: screening or confirmatory test? J Clin Pathol. 1992 Jan;45(1):37–41. doi: 10.1136/jcp.45.1.37. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Young H., Moyes A., McMillan A., Robertson D. H. Screening for treponemal infection by a new enzyme immunoassay. Genitourin Med. 1989 Apr;65(2):72–78. doi: 10.1136/sti.65.2.72. [DOI] [PMC free article] [PubMed] [Google Scholar]