. 2015 Mar 20;10(3):e0119144. doi: 10.1371/journal.pone.0119144

Polybrominated Diphenyl Ethers (PBDEs) in PM2.5, PM10, TSP and Gas Phase in Office Environment in Shanghai, China: Occurrence and Human Exposure

Yue Li 1, Ling Chen 1,*, Duong Minh Ngoc 1, Yan-Ping Duan 1,2,*, Zhi-Bo Lu 1, Zhi-Hao Wen 1, Xiang-Zhou Meng 1
Editor: Josué Sznitman3
PMCID: PMC4367993  PMID: 25793925

Abstract

To evaluate risk via inhalation exposure of polybrominated diphenyl ethers (PBDEs) in office environment, thirty-six pairs air samples including PM2.5 (particles with aerodynamic diameter less than 2.5 μm), PM10 (particles with aerodynamic diameter less than 10 μm), total suspended particles (TSP) with matching gas phase were collected in office environment in Shanghai, China. The average concentrations of PM2.5, PM10 and TSP were 20.4, 27.2 and 50.3 μg/m3, respectively. Σ15PBDEs mean concentrations in PM2.5, PM10, TSP and gas phase were 51.8, 110.7, 148 and 59.6 pg/m3, respectively. Much more PBDEs distributed in fine fractions than coarse ones. PBDEs congener profiles found in PM2.5, PM10 and TSP (dominated by BDE-209) were different from that in gas phase (dominated by the tri- to penta-BDEs). Approximately 3.20 pg/kg/d PM2.5 bound PBDEs can be inhaled into the lung; 3.62 pg/kg/d PM10-PM2.5(particles with aerodynamic diameter of 2.5-10 μm) bound PBDEs tended to be deposited in the upper part of respiratory system, and the intake of PBDEs via gas-phase was 2.74 pg/kg/d. The exposure of PBDEs was far below the minimal risk levels (MRLs), indicating lower risk from PBDEs via inhalation in the studied office in Shanghai.

Introduction

In recent years, some studies have shown that some brominated flame retardants, especially polybrominated diphenyl ethers (PBDEs), are potentially toxic, bio-accumulative, ubiquitous and persistent in the environment [1]. Human exposure to PBDEs has been linked to changes in neurodevelopment and reproduction, adverse birth outcomes and disruption of thyroid and reproductive hormone homeostasis [24]. As additives, PBDEs can presumably enter the environment by releasing from products, such as televisions, polyurethane, computers, etc [1]. Therefore, the indoor environment has been considered to be important for human exposure to PBDEs. Wu et al.[5] reported that the indoor environment played a prominent role as an exposure media of PBDEs. Many studies have reported PBDEs concentrations in residences in many countries [610]. However, information is rather limited regarding levels in offices and other workplaces [11]. Office workers are often in close to office equipment such as computers, printer and other equipment containing PBDEs which may cause serious exposure [12].Therefore, there is a need to assess exposure to PBDEs in office environment.

Like other semi-volatile organic compounds (SVOCs), PBDEs partition between the gaseous and the particulate phase in the atmosphere [13]. These PBDEs bound to particulate matters (PM) may be more persistent in indoor environment due to slow degradation (microbial and photolysis) and other dissipation (volatilization, dissolution) processes [14]. Fine particulates are associated with mortality because they can be deposited much more deeply in the lungs than coarse ones when inhaled. Therefore, indoor PM2.5 (particles with aerodynamic diameter less than 2.5 μm) has caused a great deal of attention [15]. Ohura et al. [16] reported that exposure to PM2.5 bound PAHs is particularly worrisome for both children and adults who spend over 10 h home every day. Ni et al.[17] measured PBDE levels bound different particle size dust from central air conditioner filters in a new office building. To our best knowledge, no study on PBDEs bound to different size PM in office air has been published.

The objectives of this study were to investigate mass concentrations of PM2.5, PM10 (particles with aerodynamic diameter less than 10 μm), TSP (total suspended particles) and PBDEs levels in PM2.5, PM10, TSP and gas phase in a representative office in Shanghai, China; to assess the risk of PBDEs exposure via inhalation in office environment.

Materials and Methods

Ethics statement

No specific permissions were required for the described field studies in Shanghai and the field studies did not involve endangered or protected species. The specific location of our study is located at 31°30’N, 121°51’E in Shanghai, China.

Chemicals

Nineteen PBDEs congeners (BDE-17, 28, 33, 47, 49, 66, 99, 100, 138, 153,154, 183, 190, 196, 203, 206, 207,208, and 209) (purity >99%) were purchased from Accu Standards (New Haven, CT, USA). BDE-50 and BDE-172 used as surrogate standards and BDE-118 (purity >99%) and BDE-128 (purity >99%) used as internal standards were also purchased from Accu Standards.

Sampling sites

The study was conducted in Shanghai in the Eastern China. The representative office was selected using the following criteria: location, scale, electronic and electrical equipment, flooring, building age and ventilation pattern, etc. The selected office building is located in downtown Shanghai which was not adjacent to any industrial activity; it is somehow representative of a white-collar working office. The studied office located on the third floor covers an area of 1450 m2 with the height of 3 m. The offices were equipped with common office furniture and electronic products. There is about 350 staff; each of them has a computer and a desktop phone. A printer is shared between 14 staff members. There are also a lot of humidifiers, water dispensers and other electrical and electronic equipment. The office was occupied all the day with a few occupants on duty during the night, so the central air conditioner operated all day. The indoor temperature was 21–25°C and the humility was 45%–70%. The windows of the whole building are completely closed all the time. There are automatic controls for entrance doors of offices. The ventilation rate in this study is significantly lower than others with windows opened (natural ventilation). Central air conditioners are used to recirculate indoor air, with more than 90% of the supply-air typically being recirculated.

Sample collection

PM2.5, PM10, TSP and gas phase samples were collected using two high volume air samplers (ECHO HiVol, Italy).Six sampling events were conducted in June, July, August, December 2012 and January, February 2013, respectively. During sampling, particles and gas phase samples were isolated from the atmosphere by drawing air through a quartz fiber filter (QFF, 102 mm in diameter, Munktell, Sweden) and polyurethane foam (PUF, 65 mm× 75 mm, TISCH, USA)at a flow rate of about 0.2 m3/min. PM2.5 and PM10 were collected using PM2.5 and PM10 cyclones, respectively. To avoid disturbing most staff during the day, the sampler was operated from midnight to the early morning and the sampling process was repeated for 3 days until 300 m3 of air was sampled. The time interval for collecting PM2.5, PM10 and TSP with matching gas phase samples was 7 days. To obtain duplicate samples, two air samplers were operated simultaneously. All samples were collected from the atmosphere at a height of 1.5 m above ground.

Before being used, QFFs were baked at 450°C for 4 h and PUF plugs were Soxhlet extracted for 48 h with methanol and for another 48 h with an acetone and hexane mixture (1:1) to remove any organic containment. After sampling, the QFFs were wrapped with aluminum foils and sealed in double-layer polyethylene bags, and PUFs were placed in solvent rinsed glass cartridges with PTEE covers, and then transported to the laboratory and stored at -20°C until extraction. The concentrations of PM2.5, PM10 and TSP were determined by weighing the filters after conditioning the filter at 33% relative humidity and 22°C before and after sampling.

Sample extraction and PBDEs analysis

The QFFs and PUF plugs spiked with surrogate standards were extracted with a Soxhlet extractor using 150 ml dichloromethane for 48 h. The extract was rotary-evaporated to about 2 ml and solvent-exchanged to hexane, and then 4 ml concentrated sulfuric acid was added. Each extract was subsequently cleaned with a gel permeation chromatography column (40 g Bio-Beads SX-3). The final extract volume was evaporated to 100 μL under a gentle N2 stream. Internal standards were added before instrumental analysis.

PBDEs congeners were quantified with a Shimadzu GCMS-QP 2010 plus instrument with the selective ion monitoring (SIM) mode. A DB-5 column (15 m × 0.25 mm × 0.1 μm, J&W Scientific) was employed. The analysis of PBDEs congeners using the isotope internal standard method followed our previous study[18].

Quality assurance/quality control (QA/QC)

Breakthrough of gas-phase chemicals was tested by using a second PUF plug in series with the first one. The PBDEs contents in the second plug were less than 7% of those in the first plug for all congeners.

For each batch of PM2.5, PM10, TSP and gas samples, a procedural blank, spiked blank and drift tests were processed. All targets were lower than the limit of detection (LOD) in procedural blanks, so they were not subtracted from the sample measurement. The surrogate recovery of BDE-50 and BDE-172 was 79.3 ± 4.5% and 86.5 ± 6.5%, respectively. The quantification was performed with a seven-point calibration curve with 20 μg/L 13C-BDE-118 and 13C-BDE-128 as internal standards (R 2 >0.999) for both lower and higher BDE congeners. Both external calibration and internal standard (BDE-118) calibration were applied in the quantification of BDE-209, while internal standard calibration was used for other congeners. To check drift, standards were run after every 6 samples, and the results were unacceptable unless the relative standard deviation for individual PBDEs congener in standards was less than 10%. Recoveries of targets ranged from 81.5% to 89.7%, and relative standard deviations ranged from 3.2% to 7.9% in spiked blank samples. Reported concentrations were not surrogate recovery corrected.

Risk assessment

Based on the NOAELHEC values (human equivalent no-observed-adverse-effect level), the MRL (Minimal Risk Levels) is derived as follows:

MRL=(NOAELHEC)÷(UF×MF) (1)

where UF is uncertainty factor and MF is modifying factor. This method is limited to intermediate-duration (15–364 days) inhalation study of PBDEs.

The NOAELHEC was calculated from the duration-adjusted NOAEL (NOAELADJ) using EPA RfDs methodology as follows:

NOAELHEC=NOAELADJ×RDDR (2)

The regional deposited dose ratio (RDDR) (2.7) for the extrathoracic (ET) region was used to extrapolate deposited doses in species studied to deposited doses in human [19].

For the lower brominated PBDEs: NOAEL was 1.1 mg/m3;

NOAELADJ=1.1mg/m3×6 hours/24hours ×5days/7days=0.196mg/m3
NOAELHEC=0.196mg/m3×2.7=0.53mg/m3

The MRL was derived by dividing the NOAELHEC by UF of 30 (3 for species to species extrapolation with dosimetric adjustments and 10 for human variability) and MF of 3 (for an incomplete database reflecting a single study in one species).

MRL=0.53 mg/m3÷(30×3)=0.006mg/m3

For higher brominated PBDEs: The MRL was estimated by dividing the NOAEL (1000 mg/kg/day) by UF of 100 (10 for animal to human extrapolation and 10 for human variability). It has been suggested that deca-BDE is very poorly absorbed via inhalation (≈ 1% or less of an oral dose) and rapidly eliminated (≈ 99% of the dose within 72 hours) [20]. Then 0.001 mg/kg/day for inhalation exposure was derived. For adults, the inhalation value of 0.07 mg/day was estimated by multiplying by the body weight (70 kg) [21]. Considering the inhalation rate (0.54 m3/h = 12.96 m3/day [21]), the final MRL for deca-BDE was 0.005 mg/m3.

Statistical Analysis

One-way ANOVA was performed to assess the significance of differences. Statistical significance was evaluated at p<0.05 level. The measured PBDE data followed the normal distribution with the average and standard deviations. Data were not transformed during the analysis. All statistical analyses were performed with SPSS software (Ver 13.0; SPSS, Chicago, IL, USA).The experimental data were expressed as mean ± standard deviation (SD).

Results and Discussion

Average concentrations of PM2.5, PM10 and TSP

Because there was no significant difference between the mass concentrations of suspended particles in summer and winter in the office the average concentrations of these particles were applied (S1 Table). Table 1 showed the concentrations of PM2.5, PM10 and TSP in this study and previous studies. The average concentrations of PM2.5, PM10 and TSP were 20.4, 27.2 and 50.3 μg/m3, respectively. Higher concentrations of indoor PM were generally found in developing countries than developed countries [22]. The office concentration of PM2.5 in this study was comparable to those reported in offices in Beijing (China) [23], but much lower than those from Belgium [24]and Greece [22, 25]. Compared with the Global Air Quality Guidelines set by World Health Organization (10 μg/m3 for annual mean)and U.S. annual health standard (12 μg/m3)[26], the PM2.5 level in this study was slightly higher. In the European Union, the Air Quality Directive (Directive 1999/30/EC) established the limit values for PM10, to be accomplished by 2010 (20 μg/m3 as annual daily value)[27]. The concentration of PM10 in this study was higher than this directive. Those regulations were established for ambient air pollution. It is inappropriate to compare the indoor measurements with them, however, there is no any other regulations for indoor air quality. The ambient standard is considered to be a reasonably conservative benchmark for occupational exposure since it represents an effective maximum allowable concentration for the general population. The indoor air quality regulation is still required, so further work is needed to do to get more information to support more definitive occupational exposure.

Table 1. Average concentrations of PM2.5, PM10 and TSP in the present study and those from previous studies (μg/m3).

Location Type PM2.5 PM10 TSP PM2.5/PM10 PM2.5/TSP PM10/TSP ETS Ref
Beijing, China Offices 28.1 63 105 0.45 0.27 0.6 No [23]
Bhilai-Durg, India Offices - 278.8±84.3 - - - - Yes [28]
Antwerp, Belgium Offices 59±7 67±8 - 0.88 - - Yes [24]
Antwerp, Belgium Offices 15±0.9 20±1 - 0.75 - - No [24]
Athens, Greece Offices 199 281 - 0.71 - - Yes [25]
Seoul, Korea Offices - 99±68 - - - - Yes [29]
New, Jersey, USA Offices - 30.3±17.6 - - - - No [30]
Paris, France Offices - 53 - - - - No [31]
Thessaloniki, Greece Offices 67±32 93±43 - 0.72 - - No [22]
Shanghai, China Offices 20.4±6.9 27.2±9.3 50.3±15.7 0.75 0.40 0.54 No This study

ETS, represents environmental tobacco smoking.

Except for the offices in Belgium, the concentrations in this study were obviously lower compared to others [2225, 2831]. Several factors influenced the concentrations of PM2.5, PM10, and TSP in indoor air. It is generally thought that indoor concentrations of particles derive from indoor and outdoor sources, determined by several variables: air-exchange rate, outdoor air quality, indoor activities, aerodynamic diameter of PM emitted. etc. [32]. Because the central air conditioner operated all day, the air exchange rate (0.5 h-1)in this study is significantly lower than others with windows opened (natural ventilation)[11]. The filtration units installed with the air conditioners can also remove some of the particulate. This makes the indoor and outdoor correlation poor in the investigated office. Therefore, indoor activities and aerodynamic diameter of PM emitted may be the principal factors, especially, the tobacco smoking[33]. As expected, the smokers' office showed higher indoor PM concentrations than without environmental tobacco smoking in Table 1. Smoking is prohibited in the entire building in this study, which might be one of the reasons that the concentrations of particles were lower than others. Researchers also found that occupant-related activities may also be the source (composed of cloth fibers, skin cells, resuspended particles of origin by walking, and emission from materials handled) of the indoors with no specific source (like smoking and combustion of fuel) [34].

The ratio of PM2.5/PM10 mass concentrations was calculated as presented in Table 1. The PM2.5/PM10 ratio in the studied office was significantly higher than previous studies [23, 35]. A PM2.5/PM10 ratio of 0.5 is typical of developing country urban areas and is at the bottom of the range found in developed country urban areas (0.5–0.8) [36]. The result reflected that Shanghai was in the similar situation with developed countries. Higher PM2.5 /PM10 ratio may also be explained by the release of ultrafine particles from office equipment such as printers and copiers. There were about twenty-six printers and copiers in the studied office. Reports have identified ultrafine aerosol particle formation during operation of laser printer and copiers [37, 38]. In the study of Koivisto et al. [39], they presented how an indoor aerosol model can be used to characterize particle emitter and predict influence of the source on indoor air quality. According to their model, peak emission rates of the printers exceeded 7.0×108 s-1, and emitted mainly ultrafine particles (diameter less than 100 nm). Printer-emitted particles increased 6-h averaged particle concentration over eleven times compared to the background particle concentration. Toner and paper dust from printing devices may become airborne, generating respirable particles (PM2.5) [38, 40].

PBDEs concentrations and profiles

Among 19 target PBDE congeners, only those detected in at least 60% of the samples were quantified, including BDE-28, 33, 47, 66, 99,138, 153, 154, 183, 190, 196,203, 206,207 and 209. Here we defined Σ15PBDEs as the sum of all these congeners. Concentrations of PBDEs in PM2.5, PM10, TSP and gas phase in summer and winter are presented in Fig. 1 and S2S7 Table. The PBDEs congeners profile did not show notable seasonal variations (P>0.05). The office was occupied around the clock with a few occupants on duty during the night. The central air conditioner operated all day, so the temperature and humidity of the room fluctuated in a narrow range. The indoor temperature was 21–25°C and the humility was 45%–70%. Moreover, sample sizes were not large enough to cover all the differences statistically. Nevertheless, the concentrations in winter were slightly higher than those in summer. This may be caused by the higher organic carbon of the particulate in winter. Baek et al [29] investigated the seasonality on indoor air quality (homes, offices), and there was a general pattern of increasing levels from summer to winter for RSP and volatile organic compounds. Han et al. [41] found stronger correlation between PBDEs with organic carbon of particles suggesting that part of PBDEs was absorbed into the organic matter. This slight difference may also be caused by the smaller sample size.

Fig 1. Concentrations of PBDEs congeners in PM2.5, PM10, TSP and gas phase (Summer: June, July and August 2012; Winter: December 2012, January, and February 2013).

Fig 1

Octa-, nona- and deca-BDE were only found in the particulate phase, whereas the tri-BDE (BDE-28/33) and BDE-47 were almost exclusively present in the gas phase (89–93% and 86–91%). The tetra- to hepta-BDEs were both found in the particulate and gas phase. PBDEs distributed disproportionally between the fine and coarse fractions. Much more PBDEs distributed in fine fractions than coarse ones, especially for lower brominated PBDEs. Fine fractions contain more PBDEs, indicating higher accumulative effect. This was consistent with the result found by Wang et al. [8]; more than 80% of ΣPBDEs were associated with fine particles implying a definite enrichment in fine particles. Meanwhile, over 46% ΣPBDEs in atmospheric particles of Greece [42] were associated with particles <0.57 μm in diameter, and PBDEs in particles of larger size were substantially lower. However, the average PM2.5/TSP ratio of BDE-209 concentration was 26% in winter and 24% in summer suggesting higher brominated PBDEs existed mainly in coarse particles. BDE-209 concentrations in particles 2.5–10 μm in diameter were 64% and 54% in summer and winter, respectively. It was also found that BDE-209 was mainly associated with particles 3–10 μm in diameter [43].

No publication data on PBDEs concentrations in PM2.5 and PM10 in office air were available. PBDEs bound to different size of dust in the central air conditioner filter of an office building in Shenzhen, China [17]were selected for comparison, because central air conditioner filter dust was able to cover the essential information of PBDEs in indoor environments in a given time interval. As shown in Table 2, PBDEs concentrations in PM2.5 and PM10 in this study were slightly higher than that in dust in conditioner filter due to the different sample types and sources[17].

Table 2. Comparison of PBDEs concentrations in PM2.5, PM10, TSP and gas phase in office environment (pg/m3).

Location Number BDE-28/33 BDE-47 BDE-99 BDE-153 BDE-209 Σ15PBDEs Ref
PM2.5 Shanghai, China 6 (summer) 0.45 2.89 8.10 1.01 12.9 41.1 This study
Shanghai, China 6 (winter) 0.39 1.98 7.81 3.69 18.3 62.5 This study
Shenzhen, China a 56 0.014 0.021 0.014 0.004 7.285 10.84 [17]
PM10 Shanghai, China 6 (summer) 0.49 3.01 8.75 2.98 45.3 89.3 This study
Shanghai, China 6 (winter) 0.53 2.01 9.52 3.98 59.5 132 This study
Shenzhen, China a 56 0.089 0.132 0.086 0.022 44.75 66.61 [17]
TSP Shanghai, China 6 (summer) 0.53 3.22 9.98 3.69 50.4 126 This study
Shanghai, China 6 (winter) 0.79 2.32 13.4 4.32 70.5 170 This study
Michigan, America b 13 8 933 156 - - 1170 [11]
Sweden c 6 - 760 380 22 170 - [44]
Gas Shanghai, China 18 (summer) 3.98 20.2 16.3 3.11 - 52.8 This study
Shanghai, China 18 (winter) 5.91 25.3 19.9 3.96 - 66.4 This study
Michigan, America b 18 404 1490 259 - - 3400 [11]
Boston, America d 31 57 263 82 5.8 - - [45]
Greece e 5 - - - - - 205 [46]
Kuwait f 24 0.8 19.0 6.7 0.2 - 32.7 [47]

a central air conditioner filter dust samples, the sum of BDE-28, 47, 49, 85, 99, 100, 153, 154, 138, 183, 196, 206, 207, 208, 209;

b the sum ofBDE-17, 28, 75, 49, 71, 47, 66, 100, 99, 85, 154, 153, 138, 166, 183, 190, 203, 208, 207, 206, 209;

c the sum of BDE-47, 100, 99, 85, 154, 153, 128, 183, 209;

dthe sum of BDE-28, 47, 49,66, 75, 85, 99, 100, 138, 153, 154, 183;

e the sum of BDE-15, 32, 36, 17 25, 39, 38, 35, 62, 49, 47, 66, 100, 99, 154, 153, 183;

f the sum of 1, 2, 3, 7, 8, 10, 11, 12, 13, 15, 17, 25, 28, 30, 32, 33, 35, 37, 47, 49, 66, 71, 75, 77, 85, 99, 100, 116, 118, 119, 126, 138, 153, 154, 155, 166, 181, 183, 190,209.

Concentrations of Σ15PBDEs in TSP (124, 170 pg/m3 for summer and winter) were 1 order of magnitude lower than America [11] and Sweden [44]. BDE-209 was the dominant congener suggesting that commercial deca-BDE may have been added into the appliances. This was consistent with other studies in China [48, 49]. BDE-209 accounted for 40% and 45% of total PBDEs in summer and winter, respectively. These values were lower than the other air studies [50, 51]. The nona-BDE congeners constituted were higher than what was reported in the deca-BDE commercial mixture [52]. This may be due to debromination of BDE-209 in the atmosphere. However, higher nona-BDE may be derived from the octa-BDE DE-79 and Bromkal 79–8DE [52]. The Σ15PBDEs in gas phase (52.1 pg/m3, 66.4 pg/m3for summer and winter) in this study were lower than those reported in Greece [46], and America [11], but slightly higher than Kuwait [47]. This may be due to the room characteristics and potentially flame-retarded items. However, this analysis cannot be conducted appropriately in this study unless detailed information about different offices was obtained. Further study about the correlation between different PBDEs levels and room characteristics is required. The average ratio of BDE-47 to BDE-99 in air (including TSP and gas phase) were 1.17, between those in the technical penta-BDE mixture Bromkal 70–5DE (1.05) and DE-71 (1.27) [52], suggesting that a penta-BDE commercial mixture may also been the formula used in the equipment of the office.

Risk assessment

Daily exposure to PBDEs via inhalation

The office exposure can occur from air inhalation, dust ingestion and dermal contact. The exposure was assessed only via inhalation pathways to address inhalation exposure in office environment [21]. In this study, the risk of potential adverse health effects was calculated using mean concentrations of PBDEs in PM2.5, PM10, TSP and the gas phase during summer and winter. The exposed persons were all adults. The daily exposure dose by air inhalation (DEDair) of PBDEs in gas phase can be estimated as:

DEDair=C×IR×T×frbw (3)

where C is the average PBDEs concentration in gas phase (pg/m3), IR is inhalation rate (m3/d), T is exposure time (h), fr is the alveolar fraction retained in the lungs (a value of 0.75 was used [53]) and bw is the body weight of the exposed person (kg). With IR = 0.54 m3/h, bw = 70 kg (adults)[21], T is the exposure duration (8 h per day in the studied office).

The daily exposure dose by air inhalation (DEDair) of Σ15PBDEs in different sizes of particulate matter was estimated using the following equation.

DEDair=CPM×IR×Tbw (4)

Where CPM (pg/m3) is the PBDEs concentration in PM. Human exposure via inhalation of PM-bound and gas-phase PBDEs were calculated and presented in Table 3.

Table 3. Exposures of BDEs of PM-bound and gas-phase via inhalation (pg/kg/d).
BDE-33 BDE-47 BDE-100 BDE-99 BDE-153 BDE-138 BDE-209 Σ15PBDEs
PM2.5 0.03 0.15 0.05 0.49 0.15 0.22 1.18 3.20
PM10 0.03 0.16 0.06 0.56 0.22 0.28 3.08 6.82
PM10-PM2.5 0.01 0.01 0.01 0.07 0.07 0.07 2.11 3.62
TSP 0.04 0.17 0.10 0.72 0.24 0.31 3.92 9.05
gas 0.23 1.05 0.13 0.84 0.16 0.04 - 2.74
Total 0.27 1.22 0.23 1.56 0.41 0.35 3.92 11.8

As shown in Fig. 2, about 3.20(0.69–4.33) pg/kg/d PM2.5 bound PBDEs can be inhaled deep into the lungs and reach the pulmonary alveoli. They can cause breathing and respiratory problems [15]. The values were much higher than that (0.67 pg/kg /d) obtained via dust of central air conditioner filter with particulate diameter of 0.4–2.2 μm [17]. Meanwhile, 3.62 pg/kg/d PM10-PM2.5 bound PBDEs tended to be deposited in the upper parts of the respiratory system. However, this part of PBDEs can generally be expelled back into the throat and therefore do less harm to human health than PM2.5. The mean concentrations of PBDEs bound to particulates with diameter greater than 10 μm were 2.23 pg/kg/d. Due to inhalable particles excluding these particulates, the potential harm of this portion can be ignored in consideration of respiratory exposure. However, this portion can also be cleared from the extrathoracic region and the tracheobronchial compartment via mucociliary clearance and ingested. So this part should be taken into consideration when estimate the accurate ingestion exposure. Approximately 2.74 pg/kg/d PBDEs can be inhaled in the lungs via gas-phase. The total intake of PBDEs (11.8 pg/kg/d) was far below the lowest observed adverse effect level of 1 mg/kg/d recommended by Darnerud et al.[54]. The USEPA recommended the RfD of daily oral PBDEs exposure, and the RfD values were 0.1, 0.1, 0.2 and 7 μg/kg/d for BDE-47, 99, 153 and 209, respectively [55]. Obviously, the average intake of PBDEs congeners via inhalation for occupants in this office was far below the recommended RfD values. However, other studies have suggested that inhalation is only a minor exposure route compared to incidental dust ingestion and diet [9]. Therefore, overall and accurate risk assessment in workplace is necessary in the further work (i.e. the exposure associated with dust).

Fig 2. Daily exposure to PBDEs via inhalation of PM2.5, PM10, TSP and gas phase.

Fig 2

Health risks of inhalation PBDEs exposure

People are exposed to environmental PBDE mixtures of different congeners rather than the original commercial PBDE products. However, the toxicity data based on MRLs for environmental PBDEs are insufficient. Hence data from commercial PBDE mixtures are used to develop MRLs from environmental concentrations to PBDEs, owing to the following factors: (1) multiple mechanisms may be involved in health effects induced by PBDEs; (2) different PBDE congeners may produce effects by different mechanisms; (3) humans are exposed to complex mixtures of interacting PBDEs with differing biological activities, as well as to the lack of a suitable approach for quantitatively evaluating joint toxic action from concurrent exposures to PBDEs in the environment [56]. An MRL of 0.006 mg/m3 has been derived for intermediate-duration inhalation exposure (15–364 days) to lower brominated BDEs [57]. (The calculation of MRL was presented in materials and methods) There are obvious differences in the environmental chemistry and toxicity of deca-BDE compared to lower brominated BDEs. However, no MRL was derived for acute-, intermediate-, or chronic-duration inhalation exposure to deca-BDE due to a lack of inhalation studies for this PBDE congener. It has been suggested that deca-BDE is very poorly absorbed via inhalation (≈ 1% or less of an oral dose) and rapidly eliminated (≈ 99% of the dose within 72 hours) [20]. Therefore, inhalation MRL of deca-BDE in this study is derived based on the study of oral exposure to deca-BDE [20]. An MRL of 0.005 mg/m3 was derived for intermediate-duration inhalation exposure to deca-BDE. We divided the targets 15 PBDE congeners into two categories: the lower brominated BDEs (including BDE-28, 33, 47, 66, 99, 138, 153, 154, and 183) and higher brominated BDEs (including BDE-196, 203,206, 207, 208 and 209). As shown in Fig. 3, exposure to higher brominated BDEs via inhalation was only contributed by PM. The values were far below the MRLs (0.005 mg/m3), indicating much lower risk for higher brominated BDE in the surrounding air. Exposure to lower brominated BDEs was 22.32, 35.79 and 70.98pg/m3 for PM2.5, PM10 and gas phase respectively. The exposure to lower brominated BDEs did not exceed the value of MRLs (0.006 mg/m3), indicating lower risk of adverse health effects for inhalation exposure during working time. The present study provides useful information about PBDEs exposure and the risk of adverse health effects for office occupation population during working time. However, the MRLs in this study were derived for intermediate-duration (15–364 days) inhalation exposure. No MRLs were derived for chronic-duration inhalation exposure to PBDEs due to a lack of inhalation studies. Further study on chronic-duration inhalation exposure to PBDEs was required.

Fig 3. Health risks of inhalation PBDEs exposure via PM2.5, PM10, TSP and gas phase.

Fig 3

Conclusions

This study was the first in Shanghai, China to address exposure to PBDEs via PM2.5, PM10, TSP and gas phase in office environment. Both mass concentrations of PM10 and PM2.5were higher than the European Air Quality Directive, Global Air Quality Guidelines set by World Health Organization and U.S. annual health standard, suggesting higher PM2.5 exposure in the studied office. The PBDE congeners profile did not show notable seasonal variation. PBDEs were primarily associated with the fine fractions compared to coarse ones, especially for lower brominated PBDEs. PBDEs exposure via inhalation was below the RfD values recommended by USEPA. Both exposure amount of lower and higher brominated BDEs in PM2.5, PM10 and gas phase were far below their MRLs values, which were 0.006 mg/m3 for lower brominated BDEs and 0.005 mg/m3 for higher brominated BDEs, indicating lower risk for PBDEs in the office environment. However, further work of PBDEs exposure for office workers was also required to allow for overall and accurate risk assessment.

Supporting Information

S1 Table. Particulate mass concentrations (μg/m3) for PM2.5, PM10 and TSP.

(DOCX)

S2 Table. PBDEs concentrations (pg/m3) in different particulate matter and gas phase in June, 2012.

(DOCX)

S3 Table. PBDEs concentrations (pg/m3) in different particulate matter and gas phase in July, 2012.

(DOCX)

S4 Table. PBDEs concentrations (pg/m3) in different particulate matter and gas phase in August, 2012.

(DOCX)

S5 Table. PBDEs concentrations (pg/m3) in different particulate matter and gas phase in December, 2012.

(DOCX)

S6 Table. PBDEs concentrations (pg/m3) in different particulate matter and gas phase in January, 2013.

(DOCX)

S7 Table. PBDEs concentrations (pg/m3) in different particulate matter and gas phase in February, 2013.

(DOCX)

Acknowledgments

The authors thank Dr. Wen Zhang (Department of Civil and Environmental Engineering, New Jersey Institute of Technology) for valuable advice.

Data Availability

All relevant data are within the paper and its Supporting Information files.

Funding Statement

This study is financed by the National Key Technology R&D Program in the 12th Five-Year Plan of China: Research & Development on Suitable Key Technologies of the Village Environmental Monitoring (2012BAJ24B01). The funder had no role in study design, data collection and analysis,decision to publish, or preparation of the manuscript.

References

  • 1. Tung EW, Boudreau A, Wade MG, Atlas E. Induction of Adipocyte Differentiation by Polybrominated Diphenyl Ethers (PBDEs) in 3T3-L1 Cells. PLoS ONE. 2014; 9: e94583 10.1371/journal.pone.0094583 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 2. Johnson PI, Altshul L, Cramer DW, Missmer SA, Hauser R and Meeker JD. Serum and follicular fluid concentrations of polybrominated diphenyl ethers and in-vitro fertilization outcome. Environ Int. 2012; 45: 9–14. 10.1016/j.envint.2012.04.004 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 3. Harley KG, Chevrier J, Schall RA, Sjödin A, Bradman A and Eskenazi B. Association of prenatal exposure to polybrominated diphenyl ethers and infant birth weight. Am J Epidemiol. 2011; 174: 885–892. 10.1093/aje/kwr212 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 4. Park H-R and Loch-Caruso R. Protective effect of nuclear factor E2-related factor 2 on inflammatory cytokine response to brominated diphenyl ether-47 in the HTR-8/SVneo human first trimester extravillous trophoblast cell line. Toxicol Appl Pharm. 2014. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 5. Wu N, Herrmann T, Paepke O, Tickner J, Hale R, Harvey E, et al. Human exposure to PBDEs: Associations of PBDE body burdens with food consumption and house dust concentrations. Environ Sci Technol. 2007; 41: 1584–1589. [DOI] [PubMed] [Google Scholar]
  • 6. Toms L-ML, Bartkow ME, Symons R, Paepke O and Mueller JF. Assessment of polybrominated diphenyl ethers (PBDEs) in samples collected from indoor environments in South East Queensland, Australia. Chemosphere. 2009; 76: 173–178. 10.1016/j.chemosphere.2009.03.057 [DOI] [PubMed] [Google Scholar]
  • 7. Harrad S, Hazrati S and Ibarra C. Concentrations of polychlorinated biphenyls in indoor air and polybrominated diphenyl ethers in indoor air and dust in Birmingham, United Kingdom: implications for human exposure. Environ Sci Technol. 2006; 40: 4633–4638. [DOI] [PubMed] [Google Scholar]
  • 8. Wang W, Zheng J, Chan C-Y, Huang M-j, Cheung KC and Wong MH. Health risk assessment of exposure to polybrominated diphenyl ethers (PBDEs) contained in residential air particulate and dust in Guangzhou and Hong Kong. Atmos Environ. 2014; 89: 786–796. [Google Scholar]
  • 9. Allen JG, McClean MD, Stapleton HM, Nelson JW and Webster TF. Personal Exposure to Polybrominated Diphenyl Ethers (PBDEs) in Residential Indoor Air. Environ Sci Technol. 2007; 41: 4574–4579. [DOI] [PubMed] [Google Scholar]
  • 10. Shoeib M, Harner T, Ikonomou M and Kannan K. Indoor and outdoor air concentrations and phase partitioning of perfluoroalkyl sulfonamides and polybrominated diphenyl ethers. Environ Sci Technol. 2004; 38: 1313–1320. [DOI] [PubMed] [Google Scholar]
  • 11. Batterman S, Godwin C, Chernyak S, Jia C and Charles S. Brominated flame retardants in offices in Michigan, USA. Environ Int. 2010; 36: 548–556. 10.1016/j.envint.2010.04.008 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 12. Watkins DJ, McClean MD, Fraser AJ, Weinberg J, Stapleton HM, Sjödin A, et al. Exposure to PBDEs in the office environment: evaluating the relationships between dust, handwipes, and serum. Environ Health Perspect. 2011; 119: 1247 10.1289/ehp.1003271 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 13. Qi H, Li W-L, Liu L-Y, Song W-W, Ma W-L and Li Y-F. Brominated flame retardants in the urban atmosphere of Northeast China: Concentrations, temperature dependence and gas–particle partitioning. Sci Total Environ. 2014. [DOI] [PubMed] [Google Scholar]
  • 14. Stapleton HM, Sjodin A, Jones RS, Niehoser S, Zhang Y and Patterson DG. Serum levels of polyhrominated diphenyl ethers (PBDEs) in foam recyclers and carpet installers working in the united states. Environ Sci Technol. 2008; 42: 3453–3458. [DOI] [PubMed] [Google Scholar]
  • 15. Zhang A, Qi Q, Jiang L, Zhou F and Wang J. Population Exposure to PM2.5 in the Urban Area of Beijing. PLoS ONE. 2013; 8: e63486 10.1371/journal.pone.0063486 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 16. Ohura T, Noda T, Amagai T and Fusaya M. Prediction of personal exposure to PM2.5 and carcinogenic polycyclic aromatic hydrocarbons by their concentrations in residential microenvironments. Environ Sci Technol. 2005; 39: 5592–5599. [DOI] [PubMed] [Google Scholar]
  • 17. Ni H-G, Cao S-P, Chang W-J and Zeng H. Incidence of polybrominated diphenyl ethers in central air conditioner filter dust from a new office building. Environ Pollut. 2011; 159: 1957–1962. 10.1016/j.envpol.2010.12.007 [DOI] [PubMed] [Google Scholar]
  • 18. Duan Y-P, Meng X-Z, Yang C, Pan Z-Y, Chen L, Yu R, et al. Polybrominated diphenyl ethers in background surface soils from the Yangtze River Delta (YRD), China: occurrence, sources, and inventory. Environ Sci Pollut Res. 2010; 17: 948–956. [DOI] [PubMed] [Google Scholar]
  • 19.Biphenyls P. Toxicological profile for polybrominated biphenyls and polybrominated diphenyl ethers. 2004; Available: http://scholar.google.com/.
  • 20. Hardy M. The toxicology of the three commercial polybrominated diphenyl oxide (ether) flame retardants. Chemosphere. 2002; 46: 757–777. [DOI] [PubMed] [Google Scholar]
  • 21. Chen S-J, Ma Y-J, Wang J, Tian M, Luo X-J, Chen D, et al. Measurement and human exposure assessment of brominated flame retardants in household products from South China. J Hazard Mater. 2010; 176: 979–984. 10.1016/j.jhazmat.2009.11.138 [DOI] [PubMed] [Google Scholar]
  • 22. Gemenetzis P, Moussas P, Arditsoglou A and Samara C. Mass concentration and elemental composition of indoor PM2.5 and PM10 in University rooms in Thessaloniki, northern Greece. Atmos Environ. 2006; 40: 3195–3206. 16749681 [Google Scholar]
  • 23. Liu Y, Chen R, Shen X and Mao X. Wintertime indoor air levels of PM10, PM2.5 and PM1 at public places and their contributions to TSP. Environ Int. 2004; 30: 189–197. [DOI] [PubMed] [Google Scholar]
  • 24. Horemans B and Van Grieken R. Speciation and diurnal variation of thoracic, fine thoracic and sub-micrometer airborne particulate matter at naturally ventilated office environments. Atmos Environ. 2010; 44: 1497–1505. [Google Scholar]
  • 25. Diapouli E, Konstantinopoulos P., Chaloulakou A.N., Spyrellis N. (2004) Indoor and outdoor PM concentrations at schools in Athens Area Conference on Protection and Restoration of the Environment. Mykonos, Greece. [Google Scholar]
  • 26.Angency USEP. 2013. Available: http://www.epa.gov/pm/.
  • 27. Rodrıguez S, Querol X, Alastuey A, Kallos G and Kakaliagou O. Saharan dust contributions to PM10 and TSP levels in Southern and Eastern Spain. Atmos Environ. 2001; 35: 2433–2447. [Google Scholar]
  • 28. Gadkari NM. Study of personal–indoor–ambient fine particulate matters among school communities in mixed urban–industrial environment in India. Environ Monit Assess. 2010; 165: 365–375. 10.1007/s10661-009-0952-3 [DOI] [PubMed] [Google Scholar]
  • 29. Baek S-O, Kim Y-S and Perry R. Indoor air quality in homes, offices and restaurants in Korean urban areas—indoor/outdoor relationships. Atmos Environ. 1997; 31: 529–544. [Google Scholar]
  • 30. Heavner DL, Morgan WT and Ogden MW. Determination of volatile organic compounds and respirable suspended particulate matter in New Jersey and Pennsylvania homes and workplaces. Environ Int. 1996; 22: 159–183. [Google Scholar]
  • 31. Phillips K, Bentley M, Howard D and Alvan nG. Assessment of air quality in Paris by personal monitoring of nonsmokers for respirable suspended particles and environmental tobacco smoke. Environ Int. 1998; 24: 405–425. [PubMed] [Google Scholar]
  • 32. Braniš M, Řezáčová P and Domasová M. The effect of outdoor air and indoor human activity on mass concentrations of PM10, PM2.5, and PM1 in a classroom. Environ Res. 2005; 99: 143–149. [DOI] [PubMed] [Google Scholar]
  • 33. Ott W, Switzer P and Robinson J. Particle concentrations inside a tavern before and after prohibition of smoking: Evaluating the performance of an indoor air quality model. J Air Waste Manage. 1996; 46: 1120–1134. [DOI] [PubMed] [Google Scholar]
  • 34. Batterman SA. Characterization of particulate emissions from occupant activities in offices. Indoor air. 2001; 11: 35–48. [DOI] [PubMed] [Google Scholar]
  • 35. Naeher L, Leaderer B and Smith K. Particulate matter and carbon monoxide in highland Guatemala: indoor and outdoor levels from traditional and improved wood stoves and gas stoves. Indoor air. 2000; 10: 200–205. [DOI] [PubMed] [Google Scholar]
  • 36.Organization WH. WHO Air quality guidelines for particulate matter, ozone, nitrogen dioxide and sulfur dioxide: global update 2005: summary of risk assessment. 2006.
  • 37. Wensing M, Pinz G, Bednarek M, Schripp T, Uhde E, Salthammer T. Particle measurement of hardcopy devices Proceedings of the Healthy Building, Lisbon, Portugal: 2006; 2: 4–8. [Google Scholar]
  • 38. He C, Morawska L and Taplin L. Particle emission characteristics of office printers. Environ Sci Technol. 2007; 41: 6039–6045. [DOI] [PubMed] [Google Scholar]
  • 39. Koivisto AJ, Hussein T, Niemelä R, Tuomi T and Hämeri K. Impact of particle emissions of new laser printers on modeled office room. Atmos Environ. 2010; 44: 2140–2146. [Google Scholar]
  • 40. Lee C-W and Hsu D-J. Measurements of fine and ultrafine particles formation in photocopy centers in Taiwan. Atmos Environ. 2007; 41: 6598–6609. 17948814 [Google Scholar]
  • 41. Han W, Feng J, Gu Z, Chen D, Wu M and Fu J. Polybrominated Diphenyl Ethers in the Atmosphere of Taizhou, a Major E-Waste Dismantling Area in China. Bull Environ Contam Toxicol. 2009; 83: 783–788. 10.1007/s00128-009-9855-9 [DOI] [PubMed] [Google Scholar]
  • 42. Mandalakis M, Besis A and Stephanou EG. Particle-size distribution and gas/particle partitioning of atmospheric polybrominated diphenyl ethers in urban areas of Greece. Environ Pollut. 2009; 157: 1227–1233. 10.1016/j.envpol.2008.12.010 [DOI] [PubMed] [Google Scholar]
  • 43. Wilford BH, Thomas GO, Jones KC, Davison B and Hurst DK. Decabromodiphenyl ether (deca-BDE) commercial mixture components, and other PBDEs, in airborne particles at a UK site. Environ Int. 2008; 34: 412–419. [DOI] [PubMed] [Google Scholar]
  • 44. Sjödin A, Carlsson Ha, Thuresson K, Sjölin S, Bergman Å and Östman C. Flame retardants in indoor air at an electronics recycling plant and at other work environments. Environ Sci Technol. 2001; 35: 448–454. [DOI] [PubMed] [Google Scholar]
  • 45. Watkins DJ, McClean MD, Fraser AJ, Weinberg J, Stapleton HM and Webster TF. Associations between PBDEs in office air, dust, and surface wipes. Environ Int. 2013; 59: 124–132. 10.1016/j.envint.2013.06.001 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 46. Mandalakis M, Atsarou V and Stephanou EG. Airborne PBDEs in specialized occupational settings, houses and outdoor urban areas in Greece. Environ Pollut. 2008; 155: 375–382. [DOI] [PubMed] [Google Scholar]
  • 47. Gevao B, Al-Bahloul M, Al-Ghadban AN, Ali L, Al-Omair A, Helaleh M, et al. Polybrominated diphenyl ethers in indoor air in Kuwait: Implications for human exposure. Atmos Environ. 2006; 40: 1419–1426. [Google Scholar]
  • 48. Qu WY, Bi XH, Sheng GY, Lu SY, Fu H, Yuan J, et al. Exposure to polybrominated diphenyl ethers among workers at an electronic waste dismantling region in Guangdong, China. Environ Int. 2007; 33: 1029–1034. [DOI] [PubMed] [Google Scholar]
  • 49. Chen D, Bi X, Zhao J, Chen L, Tan J, Mai B, et al. Pollution characterization and diurnal variation of PBDEs in the atmosphere of an E-waste dismantling region. Environ Pollut. 2009; 157: 1051–1057. 10.1016/j.envpol.2008.06.005 [DOI] [PubMed] [Google Scholar]
  • 50. Hayakawa K, Takatsuki H, Watanabe I and Sakai S. Polybrominated diphenyl ethers (PBDEs), polybrominated dibenzo-p-dioxins/dibenzofurans (PBDD/Fs) and monobromo-polychlorinated dibenzo-p-dioxins/dibenzofurans (MoBPXDD/Fs) in the atmosphere and bulk deposition in Kyoto, Japan. Chemosphere. 2004; 57: 343–356. [DOI] [PubMed] [Google Scholar]
  • 51. Agrell C, ter Schure AFH, Sveder J, Bokenstrand A, Larsson P and Zegers BN. Polybrominated diphenyl ethers (PBDES) at a solid waste incineration plant I: Atmospheric concentrations. Atmos Environ. 2004; 38: 5139–5148. [Google Scholar]
  • 52. La Guardia MJ, Hale RC and Harvey E. Detailed polybrominated diphenyl ether (PBDE) congener composition of the widely used penta-, octa-, and deca-PBDE technical flame-retardant mixtures. Environ Sci Technol. 2006; 40: 6247–6254. [DOI] [PubMed] [Google Scholar]
  • 53. Chen D, Bi X, Liu M, Huang B, Sheng G and Fu J. Phase partitioning, concentration variation and risk assessment of polybrominated diphenyl ethers (PBDEs) in the atmosphere of an e-waste recycling site. Chemosphere. 2011; 82: 1246–1252. 10.1016/j.chemosphere.2010.12.035 [DOI] [PubMed] [Google Scholar]
  • 54. Darnerud PO, Eriksen GS, Johannesson T, Larsen PB and Viluksela M. Polybrominated diphenyl ethers: Occurrence, dietary exposure, and toxicology. Environ Health Perspect. 2001; 109: 49–68. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 55. Staskal DF, Scott LLF, Haws LC, Luksemburg WJ, Birnbaum LS, Urban JD, et al. Assessment of polybrominated diphenyl ether exposures and health risks associated with consumption of southern Mississippi catfish. Environ Sci Technol. 2008; 42: 6755–6761. [DOI] [PubMed] [Google Scholar]
  • 56. AfTSaD R. Toxicological profile for polybrominated biphenyls and polybrominated diphenyl ethers. Atlanta, GA: US Department of Health and Human Services; 2004: 45–48. [Google Scholar]
  • 57.Corporation GLC. Letter from Great Lakes Chemical Corporation to U.S. EPA summarizing 90-day inhalation toxicity study of octabromodiphenyl oxide in albino rats. 2001. [Google Scholar]

Associated Data

This section collects any data citations, data availability statements, or supplementary materials included in this article.

Supplementary Materials

S1 Table. Particulate mass concentrations (μg/m3) for PM2.5, PM10 and TSP.

(DOCX)

S2 Table. PBDEs concentrations (pg/m3) in different particulate matter and gas phase in June, 2012.

(DOCX)

S3 Table. PBDEs concentrations (pg/m3) in different particulate matter and gas phase in July, 2012.

(DOCX)

S4 Table. PBDEs concentrations (pg/m3) in different particulate matter and gas phase in August, 2012.

(DOCX)

S5 Table. PBDEs concentrations (pg/m3) in different particulate matter and gas phase in December, 2012.

(DOCX)

S6 Table. PBDEs concentrations (pg/m3) in different particulate matter and gas phase in January, 2013.

(DOCX)

S7 Table. PBDEs concentrations (pg/m3) in different particulate matter and gas phase in February, 2013.

(DOCX)

Data Availability Statement

All relevant data are within the paper and its Supporting Information files.