Skip to main content
Scientific Reports logoLink to Scientific Reports
. 2016 Feb 22;6:21913. doi: 10.1038/srep21913

Effect of diabetic duration on hemorheological properties and platelet aggregation in streptozotocin-induced diabetic rats

Eunseop Yeom 1, Hyeokjun Byeon 1, Sang Joon Lee 1,a
PMCID: PMC4762006  PMID: 26898237

Abstract

Diabetes mellitus with abnormal glucose concentration is associated with changes in hemorheological properties, endothelial function, and platelets hyperactivity. Disturbances may significantly be responsible for diabetes-related vascular complications. In this study, hemorheological and hemodynamic properties were measured according to diabetic duration after streptozotocin treatment in rats. For ex vivo measurements, an extracorporeal model was adopted. Flow rate and blood viscosity were measured using a microfluidic device. Erythrocyte aggregation and morphological parameters of erythrocytes were measured by modified erythrocyte sedimentation rate and the phase-contrast holography under in vitro conditions. The platelet aggregation and mean pressure in the femoral artery were estimated under ex vivo conditions. Hemorheological properties including blood viscosity, erythrocyte aggregation and shape parameters for the control group are significantly different with those for diabetic groups. The changes with respect to diabetic duration were relatively unnoticeable. However, the platelet aggregation is strongly dependent on the diabetic duration. Based on these results, hyperglycemia exposure may induce hemorheological variations in early stages of diabetes mellitus. High platelet aggregation may become more pronounced according to the diabetic duration caused by variations in hemorheological properties resulting in endothelial dysfunction. This study would be helpful in understanding the effects of diabetic duration on biophysical properties.


Diabetes mellitus is characterized by disordered metabolism and high hyperglycemia resulting from either low insulin level or high insulin resistance. Diabetes mellitus is associated with abnormal endothelial function, increase of arterial stiffness, platelet hyper-reactivity and hemorheological changes1,2,3. These resultant disturbances may play a critical role in the etiology of diabetes-related vascular complications, including arteriosclerosis, cardiac autonomic neuropathy and myocardial infarction4,5.

Among the variations, the viscosity increase of both plasma and whole blood caused by marked changes in hemorheological parameters, such as hematocrit, plasma proteins, erythrocyte aggregation, and deformability, can lead to the development of microvascular complications6,7,8. Specifically, hemorheological changes contribute to the production of vasoactive materials, such as nitric oxide (NO), prostacyclin, and endothelin, by changing shear stress on the endothelial cells9. The relationship between blood viscosity and peripheral vascular resistance was reported to be mediated by NO production10.

In previous studies using diabetic models, it was demonstrated that hyperglycemia leads to hyperaggregation and low deformability of erythrocytes by changing hemoglobin and membrane proteins of erythrocyte, and serum proteins (fibrinogen and globulins)3,11. Such hemorheological changes are implicated in the progression of retinal failure in diabetic retinopathy and renal failure in diabetic nephropathy.

Endothelial dysfunction mainly results from imbalance between reduced bioavailability of NO and abundant formation of reactive oxygen species (ROS) in the vascular wall. This dysfunctional phenomenon is accelerated in diabetics12. Impaired endothelial functions are observed in the very early stages of diabetes mellitus and hyperglycemia13. Given that NO and prostacyclin are inhibitors of platelet aggregation and leukocyte activation, the reduced bioavailability of NO in diabetes may result in platelet activation1. These activated platelets play a critical role in the progression of atherosclerotic lesion formation14. Therefore, a systematic monitoring of hemorheological properties such as blood viscosity, platelet adhesion, erythrocyte aggregation, and erythrocyte shape would provide a grasp of the pathophysiological features about the diabetes-related vascular complications.

To investigate between hemorheological properties and diabetes mellitus, various assessment techniques was adopted including rotational viscometer, ultrasonic diagnostic, erythrocyte sedimentation rate (ESR), filtration, 3D topography, optical tweezer, and microfluidic devices8,11,15,16. However, rotational viscometer requires a large amount of blood samples for repetitive tests. Ultrasonic diagnostic needs calibration procedure with varying flow speed and hematocrits, due to dependency of these factors. The ESR results are influenced by the installation angle and surface condition of test tubes. Since most techniques used to measure erythrocyte deformability handle single cells, it is difficult to measure statistically-averaged biophysical properties for many cells. In addition, they usually measure hemorheological properties under in vitro conditions. External exposure of blood samples can modify the aggregability and deformability of erythrocytes17.

For the measurement of biophysical properties under ex vivo condition, a rat extracorporeal loop model, circulating blood through an external loop that directly connects artery and vein, was employed in this study18. A number of biophysical properties were measured with the lapse of time by inserting a microfluidic device into the rat extracorporeal model. Given that the risk of developing vascular complications related with diabetes mellitus is associated with the degree and duration of hyperglycemia, we examined the effects of duration of hyperglycemia on biophysical properties, including blood viscosity, flow rate, pressure, degree of erythrocyte aggregation, erythrocyte shape, and platelet adhesion using the rat extracorporeal model and other measurement techniques.

Results

Rat conditions

The toxic effect of streptozotocin (STZ) treatment destroys pancreatic beta cells and changes physiological conditions of rat model19. Table 1 summarizes the biophysical characteristics for control and diabetic groups according to diabetic duration. The weight is gradually decreased in compliance with the duration of diabetes. Glucose concentration in blood samples was measured using an Accu-Chek® sensor instrument with test strips (Roche Diagnostics, Mannheim, Germany). Blood glucose for the control group is significantly lower than that for diabetic groups, but significant statistical difference is not observed among diabetic groups. Hematocrits are almost similar among all groups. The measured hematocrit values are relatively higher, compared with normal physiological condition20. It may be related with the dehydration of the rat due to a long-operational time. The level of fibrinogen in the plasma was measured by fibrinogen ELISA kit (Abcam, Cambridge, MA) in accordance with the manufacturer’s instructions. Fibrinogen concentration for the diabetic groups is significantly higher than that for control group. The platelet counts were measured by a semiautomated haematology analyzer (Medonic CA 620). The platelet numbers for diabetic groups are slightly lower than that for control group.

Table 1. Biophysical characteristics of normal and diabetic rat groups.

  Control DM (3 day) DM (7 day) DM (20 day)
Weight (g) 404.2 ± 15.7 364.9 ± 24.0 319.3 ± 38.1 241.9 ± 20.4*
Blood sugar (mg/dL) 67.7 ± 9.3 468.0 ± 49.2* 455.0 ± 41.4* 534.8 ± 39.4*
Hematocrit (–) 0.52 ± 0.01 0.52 ± 0.03 0.52 ± 0.04 0.49 ± 0.02
Fibrinogen (mg/mL) 3.24 ± 0.40 4.94 ± 0.25* 5.10 ± 0.25* 5.38 ± 0.30*
Platelets (×1000/μL) 735 ± 33 689.6 ± 54 704 ± 57 644 ± 49

Each value represents mean ± standard deviation.

*p < 0.001: significant difference from the control group.

Ex vivo blood viscosity

Blood viscosity and flow rate were repeatedly measured at intervals of 10 min for a total of 30 min after establishing the rat extracorporeal model. In this condition, response time, which is dependent on the flow rate, is less than 20 s. The time for observing the hydrodynamic balancing state is about 2 min. For minimization of dilution or blood loss due to ex vivo measurement, phosphate buffered saline (PBS; pH 7.4, Bio Solution, Korea) is only delivered at specific measurement instants. A blood sample was collected after 30 min of extracorporeal circulation to measure other biophysical properties including blood glucose, hematocrit, viscosity curve, aggregation, and erythrocyte shape.

The viscosity of whole blood passing through the rat extracorporeal model was measured under ex vivo condition, as depicted in Fig. 1A. The flow rate of blood was estimated from the velocity profiles (Fig. 1B) measured using the micro-PIV technique. Figure 1C shows that the measured velocity profile in the center region of the microchannel is somewhat blunt because of the low aspect ratio (H/W1) of the rectangular channel. To measure blood viscosity, the hydrodynamic balancing state was induced in the H-shaped microfluidic device by adjusting the injection flow rate of PBS solution, as depicted in the bottom insets of Fig. 1D.

Figure 1. Experimental system for ex vivo monitoring of biophysical properties.

Figure 1

(A) Blood is supplied into the extracorporeal fluidic network by connecting an extracorporeal loop to the blood vessels of a rat model. The extracorporeal loop consists of a pulse-free chamber (air cavity = 1.5 mL), and H-shaped and straight microchannels. The syringe and microfluidic devices were illustrated by the authors using SolidWorks software (Dassault Systèmes SolidWorks Corp., USA). (B) Procedure of micro-PIV measurement. The H-shaped microchannel has a width (W1) of 3000 μm and a height (H) of 80 μm. An instantaneous velocity field superimposed on the corresponding flow image is represented in the inset. (C) Axial velocity profile along the lateral position (x) of the channel. 3D velocity distribution in the channel and calculation of flow rate (Q). (D) Temporal variations in the flow rate of the PBS solution at the hydrodynamic balancing state (QPBSB) and blood flow rate (QBlood) measured by using Eq. (2). Microscopic images show hydrodynamic unbalancing and balancing states in the H-shaped microchannel. (E) Temporal variation of blood viscosity (μBlood).

Figure 1D shows the flow rate of PBS solution at the hydrodynamic balancing state (QPBSB) and the flow rate of blood (QBlood) for the control rat sample. Although both flow rates QPBSB and QBlood slightly increase and decrease for 30 min, its variances are not very noticeable. The variation of flow rate may be caused by some external factors including anesthetization and environmental stress. By using Eq. (3), blood viscosity (μBlood) can be estimated at specific measurement instants (Fig. 1E). Considering the slight variances of QPBSB and QBlood, measured values of μBlood seem to be almost similar during the ex vivo measurements. The temporal variation of μBlood is inversely correlated with that of QPBSB and QBlood, due to shear dependency of blood viscosity. Mean shear rate under ex vivo condition is approximately 2600 s−1.

Variation of in vitro blood viscosity

Since the blood viscosity estimated under ex vivo condition depicts only the hemorheological property at a specific flow condition, the variation of blood viscosity according to shear rate was obtained by changing the flow rate of collected blood sample based on the relation between shear rate and flow rate. The input flow rate of a syringe pump was varied from 0.1 to 25 mL/h. Figure 2A shows variation of blood viscosity in a normal rat sample with respect to shear rate Inline graphic. A number of different fitting equations have been used to depict blood viscosity according to shear rate21. Among these equations, the following Carreau model was adopted for blood viscosity prediction22.

Figure 2. Variation of blood viscosity measured under in vitro condition.

Figure 2

(A) Variation of blood viscosity according to shear rate. A curve fitted with Carreau model is included. (B) Viscosity values at zero shear rate (μ0) in the Carreau model are depicted according to duration of diabetes (DDiabetes). The line in the box represents median value. (*p < 0.001: significant difference from the control group).

graphic file with name srep21913-m2.jpg

where, μ, μ0, λ and n represent viscosity values at infinite and zero shear rates, relaxation time, and power index, respectively. As expected, a line fitted with Carreau model is well matched with the measured viscosity data. A fitting parameter μ0 is depicted by the results in a box plot representation to compare different viscosity degree according to the duration of diabetes (DDiabetes) (Fig. 2B). Mean value of μ0for the control group is significantly lower than that for the diabetic groups. However, statistical difference between the diabetic groups is not observed.

Variation of modified ESR

To determine the extent of erythrocyte aggregation, the modified ESR value was measured. Aggregated erythrocytes are easily sedimented by gravity (Fig. 3A). Right panel of Fig. 3A shows optical images with respect to time. As expected, the volume of the erythrocyte-depleted plasma (∆V) is gradually increased with lapse of time. Different degrees of erythrocyte aggregation between groups were compared by calculating Inline graphic (Fig. 3C). Similar to the results of blood glucose and viscosity, Inline graphic values for diabetic groups are markedly higher than that for the control group regardless of diabetic duration. The hyperaggregation of erythrocytes in diabetic groups can be elucidated by using the depletion theory. Since the osmotic force caused by the different concentrations of long-chain macromolecules between surface of erythrocyte and the bulk plasma makes adjacent erythrocytes aggregate together, the increased fibrinogen in STZ rat model gives rise to a high Inline graphic23,24.

Figure 3. Measured modified ESR values.

Figure 3

(A) Schematic of the modified ESR measurement. After loading a blood sample in a disposable syringe (1 mL), the syringe is vertically disposed in the inverted position. Typical images show the sedimentation of erythrocytes in the blood sample with respect to time (t). The syringe was illustrated by the authors using SolidWorks software. (B) Variation of ESR value Inline graphic according to DDiabetes. (*p < 0.001: significant difference from the control group).

Variation of erythrocyte shapes

The cytoplasmic viscosity of erythrocyte is highly dependent on hyperglycaemia. Variation in the membrane lipid-protein interactions may alter viscoelastic properties of erythrocyte membrane. These abnormalities in erythrocyte membrane contribute to the changes in morphological features of erythrocytes in diabetic groups. The deformability of individual erythrocytes is closely related to the morphological feature of erythrocytes11. Specifically, the surface area-to-volume ratio of a biconcave disc significantly contributes to the degree of deformability25. In order to estimate the deformability of erythrocytes for each group, 3D shape of erythrocytes was measured by the phase-contrast digital holography. Figure 4 compares 3D morphologies of normal and diabetic erythrocytes. Since the shape changes according to the duration of diabetes are not significant, 3D morphology of a diabetic sample at the 20 days diabetic duration is only represented. Diabetic erythrocytes have relatively higher cell thickness compared to that of normal erythrocytes. However, significant shape changes, such as loss of biconcave shape and echinocyte shape transformation26, are not observed.

Figure 4. 3D morphology of erythrocytes.

Figure 4

A modified version of common-path diffraction phase microscopy was utilized to measure 3D morphology of individual erythrocytes. Overall magnification is approximately 120 × . Blood sample was diluted in PBS solution with volume ratio of 1:200. Topography of (A) a control and (B) diabetic erythrocyte after 20 days from STZ treatment. Color bar indicates the depth of the erythrocyte.

To more systematically investigate the morphological changes of erythrocytes, some morphological parameters, such as perimeter, 2D area, perimeter-to-2D area ratio, volume, 3D surface, and surface area-to-volume ratio, are summarized in Table 2. Perimeter, 2D area, volume, and 3D surface do not show noticeable changes in the consideration of their relatively high standard deviations. However, the perimeter-to-area ratio and surface area-to-volume ratio for the control group are significantly different with those for diabetic groups. Similar to other hemorheological properties, changes in morphological properties between diabetic groups are relatively weak with no statistical difference.

Table 2. Morphological parameters of erythrocyte between normal and diabetic groups.

  Control DM (3 days) DM (7 days) DM (20 days)
Perimeter (μm) 20.96 ± 1.11 20.42 ± 0.76 21.33 ± 0.81 20.73 ± 0.75
2D area (μm2) 44.01 ± 2.40 41.14 ± 3.25** 44.53 ± 2.07 42.38 ± 2.59
Perimeter/Area (μm−1) 0.48 ± 0.02 0.50 ± 0.02** 0.49 ± 0.02* 0.49 ± 0.01**
Volume (fL) 81.71 ± 12.59 88.88 ± 10.94 88.57 ± 8.26 87.03 ± 9.89
3D surface area (μm2) 111.20 ± 12.34 107.08 ± 9.07 111.32 ± 8.18 111.20 ± 5.91
Surface area/volume (μm−1) 1.37 ± 0.10 1.22 ± 0.16** 1.26 ± 0.12** 1.29 ± 0.15*

Each value represents mean ± standard deviation.

*p < 0.1, **p < 0.05: significant difference from the control group.

Estimation of platelet aggregation under ex vivo condition

As depicted in Fig. 5A, the degree of platelet aggregation was estimated by quantifying the area of adhered platelets in the straight channel under ex vivo condition. Temporal variations of the area of adhered platelets were monitored to find the optimal condition in advance of the main experiments. Figure 5B shows extremely severe variation in APlatelet for a diabetic rat model with the 30 days diabetic duration. APlatelet slightly increases at the initial state after establishing the rat extracorporeal model. Subsequently, the adhered platelets are almost not observed until 20 min later. As depicted in insets (Fig. 5B(a–c)), some platelets are rapidly attached in the straight channel after 20 min. Given that large platelet aggregates are subjected to large force caused by increased fluidic resistance, large aggregates are suddenly detached from the microchannel at around t = 25 min. However, platelets are re-adhered and then the straight channel is completely blocked by platelet aggregates at 40 min. Based on this temporal variation of APlatelet, the area of platelets APlatelet at 30 min is used as the representative parameter to compare the platelet aggregation between the normal and diabetic groups.

Figure 5. Quantification of platelet adhesion under ex vivo condition.

Figure 5

(A) Procedure for measurement of platelet aggregation in the straight channel. Optical images were obtained by high-speed camera with time intervals (∆t) of 1 s. Scale bar indicates 100 μm. To distinguish adhered platelets from the flowing blood, a correlation map depicting the correlation coefficient of two consecutive images is obtained. By conducting additional image processing techniques, the area of adhered platelets (APlatelet) is obtained. (B) Temporal variation of APlatelet for a rat model with 30 days diabetic duration. Correlation maps at 10, 20, 30 min are inserted. (C) Variation of APlatelet according to the duration of diabetes DDiabetes. Typical binary images for the four groups are included. (*p < 0.005: significant difference from the control group).

Figure 5C shows a box plot representing APlatelet at t = 30 min after the ex vivo measurement according to the duration of diabetes (DDiabetes). Unlike other hemorheological properties such as blood viscosity, erythrocyte aggregation, and erythrocyte shape, the degree of platelet adhesion for diabetic groups is largely increased with diabetic duration DDiabetes. As DDiabetes increases, the standard deviation of APlatelet is also significantly increased. Platelet activated by hemodynamic features is primarily mediated by soluble fibrinogen and von Willebrand factor (vWF) which support both adhesion and aggregation of platelets. Thus, the enhanced fibrinogen and vWF in diabetic rat models induce hyper-adhesion of platelets (Table 1)27.

Observation of ex vivo hemodynamic conditions

Mean pressure variation was monitored during the ex vivo measurements. The different size of channels in the extracorporeal loop induces different shear rate at a certain part of the extracorporeal loop despite of the same flow rate. For reasonable estimation of mean pressure in the femoral artery (PArtery), the viscosity value at a specific shear condition fitted by Eq (1) was applied to Eq (5). Figure 6A shows temporal variation of PArtery with the lapse of time under ex vivo condition for the control sample. Like flow rate results (Fig. 1D), PArtery is slightly increased and then decreased in a 30 min period. A dotted line indicates the mean value of PArtery Inline graphic during the experiment time. Inline graphic was used as a parameter representing the hemodynamic condition for all groups. As depicted in the box plot of Fig. 6B, statistically different tendency of Inline graphic is not observed for all groups.

Figure 6. Estimation of mean pressure in the femoral artery under ex vivo condition.

Figure 6

(A) Temporal variation of mean pressure at the femoral artery (PArtery) of the control rat sample, estimated based on the pressure drop in the fluidic circuit. The mean pressure Inline graphic during the measurement is included. (B) Variation of Inline graphic according to duration of diabetes DDiabetes.

Discussion

Considering that glucose is an essential nutrient for body cells, abnormal glucose concentration may have a direct influence on the constituents and biochemical properties of blood circulating in vascular networks28,29. In previous studies, it was found that STZ-induced diabetes mellitus significantly alter lipid composition, mRNA and plasma protein levels16,30,31. Specifically, increase in soluble thrombomodulin (sTM), vWF and fibrinogen and decrease in activated factor XIII have also been reported in STZ diabetic models27. These alterations can induce change in hemorheological properties such as viscosity, hematocrit, plasma proteins, erythrocyte aggregation, and deformability, and platelet aggregation32.

To investigate variation of hemorheological properties and platelet aggregation according diabetic duration, some measurement methods were adopted in the present study. Although ex vivo measurement can offer more reasonable data compared with in vitro measurement based on our previous studies17, it is difficult to simultaneously measure various hemorheological properties under ex vivo conditions. Therefore, viscosity variation, erythrocyte aggregation, and shape were measured by in vitro experiments. Fortunately, platelet adhesion can be quantified without significant flow modification when blood flow is similar among ex vivo measurements. To check flow conditions of ex vivo measurements, pressures at the femoral artery were compared.

Among these hemorheological properties, blood viscosity has a profound impact on blood circulation. In this regard, the variation of viscosity according to shear rate was measured using the H-shaped microchannel. Diabetic rats were found to have relatively high viscosities compared to the control. These results are in accordance with previous studies conducted on STZ-induced rats16. The increase in blood viscosity is consistently observed after 3 days from the STZ treatment. The elevated blood viscosity may be associated with the aggregability and deformability of erythrocytes3,29.

The ESR has been widely used as a nonspecific indicator of inflammation, because it is mainly affected by erythrocyte aggregation. Specific plasma proteins of fibrinogen and globulins form intercellular layer in the vicinity of erythrocytes, leading to an aggregating force. Therefore, the increase of these proteins contributes to enhanced erythrocyte aggregation in STZ diabetic models33,34. The contribution of the erythrocyte aggregation to the increase of the blood viscosity was evaluated by measuring the modified ESR. As expected, the modified ESR result exhibits similar variation trends of blood viscosity results according to diabetic duration.

In addition, diabetic state can cause reduced deformability of erythrocytes35,36. The deformability of erythrocytes is influenced by three factors: (i) the viscosity of intracellular fluid determined by the presence of hemoglobin, (ii) the viscoelastic properties of cell membrane, and (iii) the morphological feature of erythrocytes such as diameter, concave depth, surface area, and volume. In this study, morphological parameters were intensively investigated using phase-contrast digital holography. The erythrocytes suffered from hyperglycemia have different morphology compared to healthy erythrocytes35. It was reported that the perimeter-to-2D area ratio for erythrocytes becomes high with relatively low deformability, as the glucose concentration increases37. Similar to previous studies, the perimeter-to-2D area ratios for diabetic groups have smaller values than those for the normal group with high surface area-to-volume ratios. This morphological change in diabetic groups may be resulted from lipid alterations of erythrocyte membrane caused by decreased Na+-K+-ATPase activity36,38. However, significant variations are not observed among the diabetic groups with different diabetic duration. It signifies that the slightly reduced deformability of erythrocytes caused by the morphological shape change is continuously maintained after 3 days from the STZ treatment.

A sudden shear acceleration can directly initiate platelet aggregation, independent of biochemical triggers39,40,41. Therefore, platelets can be activated when they pass through the narrow inlet of the straight channel and adhered on the downstream of straight channel. By applying the correlation mapping, platelet aggregation can be estimated by measuring the area of adhered platelets. As shown in Fig. 5C, the degree of platelet adhesion and diabetic duration have a positive correlation (R2 = 0.623). Considering the process of platelet aggregation is dependent on the shear condition42,43, the mean pressure in the femoral artery was also estimated under ex vivo conditions to check the shear condition during the measurements of platelet adhesion. The measured mean pressures indicate that no significant difference exists among all groups tested in this study. Therefore, shear conditions may not have any significant influence on the increase trend of platelet aggregation according to the duration of diabetes.

Exposure to hyperglycemia can damage or alter endothelial barrier12. Increases in the blood viscosity and erythrocyte aggregation, as well as morphological shape change induced by diabetes mellitus, may also lead to endothelial dysfunction by disturbing the blood circulation in microvessels. Impaired endothelial dysfunction under diabetic conditions can result in reduced NO bioavailability and abundant ROS formation13. This type of imbalance between NO and ROS can lead to platelet aggregation with shape change of platelets, degranulation, and rapid surface expression of adhesion molecules44. In addition, the increases of vWF and fibrinogen due to endothelial dysfunction was observed in STZ diabetic models (Table 1)27. These proteins support both adhesion and aggregation of platelets. Thus, the hyper-adhesion of platelets may become more pronounced according to the diabetic duration caused by consistent exposure to hyperglycemia and large variations in hemorheological properties resulting in endothelial dysfunction. However, the results of platelet accumulation might be influenced by some artifacts caused by extracorporeal circulation of blood. Some portions of the platelet aggregates circulating in the rat model and extracorporeal loop can promote the aggregation of platelets. Thus, the measurement time under ex vivo condition is important to quantify the degree of platelet aggregation. Through preliminary experimental results, we found that the usage of a rat sample with high diabetic duration (more than 30 days) or prolonged experiment (more than 30 min) easily blocked the straight channel due to significant adhesion of platelet aggregates. Based on these results, a suitable experimental condition for estimating the platelet aggregation and blood pressure at the artery was determined.

Conclusion

In this study, various biophysical properties, such as blood viscosity, erythrocyte aggregation, 3D morphology, and platelet aggregation, were measured according to the duration of diabetes under ex vivo and in vitro conditions. Based on these results, hyperglycemia induces variations in hemorheological properties from the very early stage of diabetes mellitus. It is caused by alteration of plasma proteins such as sTM, vWF and fibrinogen. These variations may lead to the hyper-adhesion of platelets and may be responsible for the diabetic-related vascular complications, such as nephropathy, retinopathy, and atherosclerosis in coronary and carotid arteries. Although further detailed study is required to examine the relationship between the variations of hemorheological properties and vascular complications of diabetic patients, we believe that this study would be beneficial in understanding temporal variations of hemorheological properties according to the duration of diabetes.

Methods

Fabrication of microfluidic devices

A rectangular master replica mold (height = 80 μm) was fabricated using microelectromechanical system (MEMS) technologies based on soft lithography and deep reactive-ion etching. An H-shaped microfluidic device has two identical side channels with width (W1) of 3000 μm and length of 14.4 mm. A bridge channel connecting both side channels has width of 100 μm and length of 2.4 mm. A straight microchannel has width (W2) of 1 mm and length of 10 mm. To initiate platelet aggregation in the straight microchannel, inlet region has narrow width about 100 μm and the microchannel was coated by collagen based on previous studies (Supplementary Fig. 1)40,45. After pouring Polydimethylsiloxane (PDMS; Sylgard 184, Dow Corning, USA) on the silicon replica mold, it was cured at 80 °C for 3 h. Thereafter, a PDMS block was peeled off from the silicon mold. The inlet and outlet of microchips were made with a puncher of 1.2 mm in diameter. After oxygen-plasma treatment (CUTE, Femto Science, Korea), the microfluidic device was finally prepared by bonding the PDMS block to a glass substrate.

Microfluidic devices employed for simultaneous measurements of biophysical properties, including blood pressure, viscosity, flow rate, and platelet adhesion have several distinctive advantages. First, biophysical properties of real blood can be directly measured by connecting the microfluidic devices with blood vessels of a rat model without noticeable hemorheological changes. The microfluidic devices can measure biophysical properties using small amount of sample consumptions. In addition, they do not require any calibration procedures.

Preparation of extracorporeal model using diabetic rat samples

Male Sprague-Dawley rats were exposed to a 12/12 reverse-light cycle. Type 1 diabetes with hyperglycemia was induced by intraperitoneal injection of streptozotocin (STZ; 65 mg/kg in sterile saline) to rat samples under anesthesia with isoflurane and oxygen. Rat samples were fasted for 24 h prior to the STZ injection, and then fasted for another 24 h. They were divided into four groups, depending on the duration of diabetes (control, 3, 7 and 20 days).

A rat extracorporeal model was adopted to measure some biophysical properties under ex vivo conditions (Fig. 1A)18. All experiments were conducted using 16-week-old rat samples, which were anesthetized with intramuscular injection of ketamine (100 mg/kg) and xylazine (10 mg/kg). A PE-50 tube (ID = 0.58 mm, polyethylene tube) at one end of the extracorporeal loop was cannulated into the right jugular vein. Exact amount of heparin (1500 IU/mL/kg) was precisely injected into the right jugular vein for anticoagulation. After 10 min of heparin injection, another PE-50 tube at the other end of the loop was inserted into the left femoral artery. A pulsed-free microfluidic device with 1.5 mL air cavity was installed between the femoral artery and the inlet of the H-shaped microfluidic device to supply stabilized blood samples. The outlet of the H-shaped microchannel and the inlet of the straight microchannel were connected by a Tygon tube (ID = 250 μm). The blood passing through the extracorporeal conduits was returned to the jugular vein of the rat model. The cooling effect caused by the blood circulation through the extracorporeal loop was minimized by installing a heat chamber maintained at 36 °C to 37 °C. All experimental procedures were approved by the Animal Care and Ethics Committee of Pohang University of Science and Technology, and all methods were performed in accordance with the approved guidelines.

Micro-PIV technique for flow rate measurement

As shown in Fig. 1B, a micro-PIV was used to measure blood flows in the H-shaped microchannel. The microfluidic devices were mounted on the stage of an optical microscope (Nikon, Tokyo, Japan) with 4 × objective lens (NA = 0.1). Optical images of blood flows were consecutively acquired using a high-speed camera (FASTCAM SA 1.1, Photron Ltd., San Diego, USA) at a frame rate of 5000 fps. Before applying the cross-correlation PIV algorithm to each image pair, the captured images were cropped into images of 408 pixels × 320 pixels. The detailed procedures of micro-PIV technique employed in the present study were well described in our previous studies46,47. The size of each interrogation window was 16 pixels × 32 pixels with 50% overlapping. The obtained velocity fields were filtered using a 3 × 3 median kernel. Velocity profiles were obtained by averaging the velocity field along the flow direction (y-axis).

Based on our previous study15, the measured velocity information can be postulated to represent the mean velocity of erythrocytes in the whole depth, because the depth of correlation (δC = 310 μm), which expresses the depth over which particles contribute to the cross-correlation analysis, is larger than the channel depth under present experiment condition. Therefore, the flow rate of blood (QBlood) in the microchannel can be estimated using the following equation:

graphic file with name srep21913-m9.jpg

where U(x) is the velocity profile at a specific lateral position (x); and W1 and H indicate the width and depth of the H-shaped microchannel, respectively.

Viscosity estimation

Blood sample and PBS solution were separately delivered into the two inlets of the H-shaped microfluidic device to estimate blood viscosity. The PBS solution was supplied using a syringe pump (neMESYS, Centoni Gmbh, Germany) with a 5 mL plastic syringe (BD). When a blood sample does not move in the bridge channel (hydrodynamic balancing state), the viscosity of the blood sample (μBlood) can be simply estimated based on the following analytical formula:

graphic file with name srep21913-m10.jpg

where, μPBS, and QPBSB denote viscosity, and the flow rate of PBS solution at the hydrodynamic balancing condition, respectively. The viscosity of PBS solution (μPBS) is approximately 1.00 ± 0.05 cP48. Details of viscosity estimation procedure were well described in our previous study46.

Modified erythrocyte sedimentation rate measurement

Modified ESR value was measured using a 1 mL plastic syringe (BD). Based on our previous results, the hematocrit of the blood samples was adjusted to 20% for effective measurement of erythrocyte aggregation using the modified ESR value15. After loading blood sample (0.9 mL) into a disposable syringe, the syringe was disposed in an inverted vertical posture (Fig. 3A). Snap shots of the syringe were continuously captured with a digital camera (D700, Nikon, Japan) at 5 min intervals for 12 h. Boundaries between erythrocytes and erythrocyte-depleted plasma were determined by adopting Canny’s method49. ESR value Inline graphic can be calculated by dividing the volume of erythrocyte-depleted plasma (∆V) by the measurement time (t = 12 h).

Phase-contrast digital holography

Whole blood was diluted 1:200 in the PBS solution and then placed between slide glass and cover glass. Prepared blood sample was mounted on the stage of an upright microscope (Eclipse i50, Nikon) with 40 × objective lens (NA = 0.75). Additional relay optics were used to provide overall magnification of 120 × . A modified version of common-path diffraction-related phase microscopy was utilized to measure the 3D morphological shape of erythrocytes50. The laser beam (He–Ne laser; λ = 633 nm) is separated into two beams by a beam splitter. One beam passes through the test sample and the other beam, which is used as the reference beam, passes through a pinhole. A hologram, made by interference between the two beams, was captured by a charge-coupled device camera (PCO 2000, 2K × 2K pixel, 7.4 μm/pixel). An angular spectrum algorithm was employed for numerical reconstruction of hologram images. Perimeter, 2D projected area, 3D surface area and volume of erythrocytes were evaluated from the reconstructed phase images. The detailed procedures of hologram reconstruction and cell analysis were well described in our previous study51.

Quantification of adhered platelets

Before establishing the rat extracorporeal model, the conduits, except for the straight microchannel, were incubated with 2% bovine serum albumin (Sigma, MO) for 1 h at room temperature to inhibit platelet deposition and fibrin adhesion. After 1 h, BSA is washed by PBS solution. A total of 60 images of blood flow and adhered platelets in the straight microchannel were consecutively acquired by the high-speed CMOS camera (FASTCAM SA 1.1) with time interval of 1 s at 30 min after establishing the extracorporeal rat model. In order to accurately distinguish the adhered platelets from the flowing blood, a correlation map, labeling the 2D correlation coefficient between small tiles of two consecutive images, was adopted (Fig. 5A)52. Each optical image was divided into small tiles of m × n. The 2D correlation coefficient (R) of tiles was calculated using the following equation:

graphic file with name srep21913-m12.jpg

where A and B represent the tiles centered at (Ci, Cj) in two consecutive images, (i, j) is the pixel coordinate of the tile, and Inline graphic and Inline graphic denote the mean intensity of the tiles A and B, respectively. The size of each tile used in this study is 11 pixels × 11 pixels. The correlation maps were converted into binary images by applying the thresholding with an optimal value of Otsu’s algorithm. Finally, area for adhered platelets (APlatelet) is estimated by calculating the total number of any nonzero pixels in the binary image.

Estimation of mean pressure in the femoral artery

A discrete fluidic circuit of the present extracorporeal model is composed of fluidic resistances, air compliance of the pulse-free chamber, and flow rates. By adding pressure drops in the fluidic circuits from hydrodynamic balancing pressure in the microfluidic device, the mean pressure in the femoral artery (PArtery) can be estimated using the following equation;

graphic file with name srep21913-m15.jpg

where, μn, Ln and Dn represent the blood viscosity, characteristic length and hydraulics diameter at a certain part of the extracorporeal network (Supplementary Fig. 2). PPBSB denotes the hydrodynamic balancing pressure in the H-shaped microchannel. In the prediction of blood pressure, it is assumed that blood is circulated in the extracorporeal network without bleeding and no change in the fluidic resistance. However, due to accumulation of platelet aggregates in the straight channel, the pressure in the artery (PArtery) would be somewhat overestimated.

Statistical analysis

Results in each group indicate the mean value evaluated from five test samples. The statistical analysis of the data was carried out by Student t-test between control and diabetic groups. The statistical analysis among diabetic groups are not observed in all Tables and Figures.

Additional Information

How to cite this article: Yeom, E. et al. Effect of diabetic duration on hemorheological properties and platelet aggregation in streptozotocin-induced diabetic rats. Sci. Rep. 6, 21913; doi: 10.1038/srep21913 (2016).

Supplementary Material

Supplementary Information
srep21913-s1.pdf (173.3KB, pdf)

Acknowledgments

We greatly appreciate Dr. Nam’ permission to use the drawing of the rat in the schemes of the proposed system (Figures 1 and S2). This work was supported by the National Research Foundation of Korea (NRF) grant funded by the Korea Government (MSIP) (No. 2008–0061991).

Footnotes

Author Contributions E.Y. and S.J.L. proposed the study. E.Y. and H.B. performed the experiment and analyzed the data. E.Y. and S.J.L. wrote the paper. All authors participated in completing the manuscript.

References

  1. Schafer A. et al. Improved endothelial function and reduced platelet activation by chronic HMG-CoA-reductase inhibition with rosuvastatin in rats with streptozotocin-induced diabetes mellitus. Biochem. Pharmacol. 73, 1367–1375 (2007). [DOI] [PubMed] [Google Scholar]
  2. Wilkinson I. B. et al. Increased augmentation index and systolic stress in type 1 diabetes mellitus. QJM 93, 441–448 (2000). [DOI] [PubMed] [Google Scholar]
  3. Cho Y. I., Mooney M. P. & Cho D. J. Hemorheological disorders in diabetes mellitus. J. Diabetes Sci. Technol. 2, 1130–1138 (2008). [DOI] [PMC free article] [PubMed] [Google Scholar]
  4. Loomans C. J. et al. Endothelial progenitor cell dysfunction: a novel concept in the pathogenesis of vascular complications of type 1 diabetes. Diabetes 53, 195–199 (2004). [DOI] [PubMed] [Google Scholar]
  5. Beckman J. A., Creager M. A. & Libby P. Diabetes and atherosclerosis: epidemiology, pathophysiology, and management. JAMA 287, 2570–2581 (2002). [DOI] [PubMed] [Google Scholar]
  6. Tamariz L. J. et al. Blood viscosity and hematocrit as risk factors for type 2 diabetes mellitus. The atherosclerosis risk in communities (ARIC) study. Am. J. Epidemiol. 168, 1153–1160 (2008). [DOI] [PMC free article] [PubMed] [Google Scholar]
  7. Ford E. S. Leukocyte count, erythrocyte sedimentation rate, and diabetes incidence in a national sample of US adults. Am. J. Epidemiol. 155, 57–64 (2002). [DOI] [PubMed] [Google Scholar]
  8. Cloutier G., Zimmer A., Yu F. T. & Chiasson J. L. Increased shear rate resistance and fastest kinetics of erythrocyte aggregation in diabetes measured with ultrasound. Diabetes Care 31, 1400–1402 (2008). [DOI] [PMC free article] [PubMed] [Google Scholar]
  9. Salazar-Vazquez B. Y., Intaglietta M., Rodriguez-Moran M. & Guerrero-Romero F. Blood pressure and hematocrit in diabetes and the role of endothelial responses in the variability of blood viscosity. Diabetes Care 29, 1523–1528 (2006). [DOI] [PubMed] [Google Scholar]
  10. Martini J., Carpentier B., Negrete A. C., Frangos J. A. & Intaglietta M. Paradoxical hypotension following increased hematocrit and blood viscosity. Am. J. Physiol. Heart Circ. Physiol. 289, H2136–2143 (2005). [DOI] [PubMed] [Google Scholar]
  11. Tomaiuolo G. Biomechanical properties of red blood cells in health and disease towards microfluidics. Biomicrofluidics 8, 051501 (2014). [DOI] [PMC free article] [PubMed] [Google Scholar]
  12. Wagenknecht L. E. et al. Diabetes and progression of carotid atherosclerosis: the insulin resistance atherosclerosis study. Arterioscler. Thromb. Vasc. Biol. 23, 1035–1041 (2003). [DOI] [PubMed] [Google Scholar]
  13. Guerci B., Bohme P., Kearney-Schwartz A., Zannad F. & Drouin P. Endothelial dysfunction and type 2 diabetes. Part 2: altered endothelial function and the effects of treatments in type 2 diabetes mellitus. Diabetes Metab. 27, 436–447 (2001). [PubMed] [Google Scholar]
  14. Massberg S. et al. A critical role of platelet adhesion in the initiation of atherosclerotic lesion formation. J. Exp. Med. 196, 887–896 (2002). [DOI] [PMC free article] [PubMed] [Google Scholar]
  15. Yeom E. & Lee S. J. Microfluidic-based speckle analysis for sensitive measurement of erythrocyte aggregation: A comparison of four methods for detection of elevated erythrocyte aggregation in diabetic rat blood. Biomicrofluidics 9, 024110 (2015). [DOI] [PMC free article] [PubMed] [Google Scholar]
  16. Xue W. L. et al. Effect of Trigonella foenum-graecum (fenugreek) extract on blood glucose, blood lipid and hemorheological properties in streptozotocin-induced diabetic rats. Asia Pac. J. Clin. Nutr. 16 Suppl 1, 422–426 (2007). [PubMed] [Google Scholar]
  17. Yeom E., Kang Y. J. & Lee S. J. Hybrid system for ex vivo hemorheological and hemodynamic analysis: A feasibility study. Sci. Rep. 5, 11064 (2015). [DOI] [PMC free article] [PubMed] [Google Scholar]
  18. Nam K. H., Yeom E. & Lee S. J. Extracorporeal bypass model of blood circulation for the study of microvascular hemodynamics. Microvasc. Res. 83, 372–375 (2012). [DOI] [PubMed] [Google Scholar]
  19. Shimomura I. et al. Insulin selectively increases SREBP-1c mRNA in the livers of rats with streptozotocin-induced diabetes. Proc. Natl. Acad. Sci. USA 96, 13656–13661 (1999). [DOI] [PMC free article] [PubMed] [Google Scholar]
  20. Baskurt O. K., Farley R. A. & Meiselman H. J. Erythrocyte aggregation tendency and cellular properties in horse, human, and rat: a comparative study. Am. J. Physiol. Heart Circ. Physiol. 273, H2604–2612 (1997). [DOI] [PubMed] [Google Scholar]
  21. Cho Y. I. & Kensey K. R. Effects of the non-Newtonian viscosity of blood on flows in a diseased arterial vessel. Part 1: Steady flows. Biorheology 28, 241–262 (1991). [DOI] [PubMed] [Google Scholar]
  22. Carreau P. J., De Kee D. & Chhabra R. P. Rheology of polymeric systems: principles and applications. (Hanser Publishers Munich, 1997). [Google Scholar]
  23. Van Oss C. J., Arnold K. & Coakley W. T. Depletion flocculation and depletion stabilization of erythrocytes. Cell Biophys. 17, 1–10 (1990). [DOI] [PubMed] [Google Scholar]
  24. Bishop J. J., Popel A. S., Intaglietta M. & Johnson P. C. Rheological effects of red blood cell aggregation in the venous network: a review of recent studies. Biorheology 38, 263–274 (2001). [PubMed] [Google Scholar]
  25. Reinhart W. H. & Chien S. Red cell rheology in stomatocyte-echinocyte transformation: roles of cell geometry and cell shape. Blood 67, 1110–1118 (1986). [PubMed] [Google Scholar]
  26. Park Y. et al. Metabolic remodeling of the human red blood cell membrane. Proc. Natl. Acad. Sci. USA 107, 1289–1294 (2010). [DOI] [PMC free article] [PubMed] [Google Scholar]
  27. Haidara M., Khloussy H., Ammar H. & Kassem L. A. A. Impact of a-tocopherol and vitamin C on endothelial markers in rats with streptozotocin-induced diabetes. Med. Sci. Monit. 10, Br41–Br46 (2004). [PubMed] [Google Scholar]
  28. Caimi G. et al. Diabetes mellitus: mean erythrocyte aggregation, glycometabolic pattern, red cell Ca2+content, and erythrocyte membrane dynamic properties. Microvasc. Res. 46, 401–405 (1993). [DOI] [PubMed] [Google Scholar]
  29. Singh M. & Shin S. Changes in erythrocyte aggregation and deformability in diabetes mellitus: a brief review. Indian J. Exp. Biol. 47, 7–15 (2009). [PubMed] [Google Scholar]
  30. Kesavan S. K. et al. Proteome wide reduction in AGE modification in streptozotocin induced diabetic mice by hydralazine mediated transglycation. Sci. Rep. 3, 2941 (2013). [DOI] [PMC free article] [PubMed] [Google Scholar]
  31. Li Y. G. et al. 1-deoxynojirimycin inhibits glucose absorption and accelerates glucose metabolism in streptozotocin-induced diabetic mice. Sci. Rep. 3, 1377 (2013). [DOI] [PMC free article] [PubMed] [Google Scholar]
  32. Irace C. et al. Influence of blood lipids on plasma and blood viscosity. Clin. Hemorheol. Microcirc. 57, 267–274 (2014). [DOI] [PubMed] [Google Scholar]
  33. Khan H. A. & Ola M. S. Markers of blood coagulation, lipid profile, renal function test and serum electrolytes in streptozotocin-induced diabetic rats. Biomed Res-India 23, 421–424 (2012). [Google Scholar]
  34. Li Q., Li L. & Li Y. Enhanced RBC aggregation in type 2 diabetes patients. J. Clin. Lab. Anal. 1, 1–3 (2014). [DOI] [PMC free article] [PubMed] [Google Scholar]
  35. Buys A. V. et al. Changes in red blood cell membrane structure in type 2 diabetes: a scanning electron and atomic force microscopy study. Cardiovasc. Diabetol. 12, 25 (2013). [DOI] [PMC free article] [PubMed] [Google Scholar]
  36. Mohamed J., Wen H. K., Idris M. H., Zainalabidin S. & Budin S. B. Reduced red blood cell membrane damage in streptozotocin-induced diabetic rats supplemented with roselle (UKMR-2) calyx extract. Pak. J. Biol. Sci. 17, 682–688 (2014). [DOI] [PubMed] [Google Scholar]
  37. Babu N. & Singh M. Influence of hyperglycemia on aggregation, deformability and shape parameters of erythrocytes. Clin. Hemorheol. Microcirc. 31, 273–280 (2004). [PubMed] [Google Scholar]
  38. Sureka C., Ramesh T. & Begum V. H. Attenuation of erythrocyte membrane oxidative stress by Sesbania grandiflora in streptozotocin-induced diabetic rats. Biochem. Cell Biol. 93, 385–395 (2015). [DOI] [PubMed] [Google Scholar]
  39. Maxwell M. J. et al. Identification of a 2-stage platelet aggregation process mediating shear-dependent thrombus formation. Blood 109, 566–576 (2007). [DOI] [PubMed] [Google Scholar]
  40. Nesbitt W. S. et al. A shear gradient-dependent platelet aggregation mechanism drives thrombus formation. Nat. Med. 15, 665–673 (2009). [DOI] [PubMed] [Google Scholar]
  41. Ha H. & Lee S. J. Hemodynamic features and platelet aggregation in a stenosed microchannel. Microvasc. Res. 90, 96–105 (2013). [DOI] [PubMed] [Google Scholar]
  42. Savage B., Saldivar E. & Ruggeri Z. M. Initiation of platelet adhesion by arrest onto fibrinogen or translocation on von Willebrand factor. Cell 84, 289–297 (1996). [DOI] [PubMed] [Google Scholar]
  43. Savage B., Almus-Jacobs F. & Ruggeri Z. M. Specific synergy of multiple substrate-receptor interactions in platelet thrombus formation under flow. Cell 94, 657–666 (1998). [DOI] [PubMed] [Google Scholar]
  44. Schwarz U. R., Kobsar A. L., Koksch M., Walter U. & Eigenthaler M. Inhibition of agonist-induced p42 and p38 mitogen-activated protein kinase phosphorylation and CD40 ligand/P-selectin expression by cyclic nucleotide-regulated pathways in human platelets. Biochem. Pharmacol. 60, 1399–1407 (2000). [DOI] [PubMed] [Google Scholar]
  45. Tovar-Lopez F. J. et al. A microfluidics device to monitor platelet aggregation dynamics in response to strain rate micro-gradients in flowing blood. Lab Chip 10, 291–302 (2010). [DOI] [PubMed] [Google Scholar]
  46. Yeom E., Kang Y. J. & Lee S. J. Changes in velocity profile according to blood viscosity in a microchannel. Biomicrofluidics 8, 034110 (2014). [DOI] [PMC free article] [PubMed] [Google Scholar]
  47. Yeom E., Nam K. H., Paeng D. G. & Lee S. J. Improvement of ultrasound speckle image velocimetry using image enhancement techniques. Ultrasonics 54, 205–216 (2014). [DOI] [PubMed] [Google Scholar]
  48. Kang Y. J., Yeom E. & Lee S. J. A microfluidic device for simultaneous measurement of viscosity and flow rate of blood in a complex fluidic network. Biomicrofluidics 7, 054111 (2013). [DOI] [PMC free article] [PubMed] [Google Scholar]
  49. Canny J. A computational approach to edge detection. IEEE Trans. Pattern Anal. Mach. Intell. 8, 679–698 (1986). [PubMed] [Google Scholar]
  50. Popescu G., Ikeda T., Dasari R. R. & Feld M. S. Diffraction phase microscopy for quantifying cell structure and dynamics. Opt. Lett. 31, 775–777 (2006). [DOI] [PubMed] [Google Scholar]
  51. Seo K. W., Choi Y. S., Seo E. S. & Lee S. J. Aberration compensation for objective phase curvature in phase holographic microscopy. Opt. Lett. 37, 4976–4978 (2012). [DOI] [PubMed] [Google Scholar]
  52. Yeom E., Nam K. H., Jin C., Paeng D. G. & Lee S. J. 3D reconstruction of a carotid bifurcation from 2D transversal ultrasound images. Ultrasonics 54, 2184–2192 (2014). [DOI] [PubMed] [Google Scholar]

Associated Data

This section collects any data citations, data availability statements, or supplementary materials included in this article.

Supplementary Materials

Supplementary Information
srep21913-s1.pdf (173.3KB, pdf)

Articles from Scientific Reports are provided here courtesy of Nature Publishing Group

RESOURCES