Abstract
Digital subtraction angiography was used as the sole imaging technique in 95 infants and children aged 13 hours to 16 years undergoing cardiac catheterisation for the investigation of congenital heart disease. Injections of diluted contrast medium were made selectively at central sites, and the images were obtained using continuous image intensification fluoroscopy at either 32.25 nC/kg/s (125 microR /s) or 129 nC/kg/s (500 microR /s). In all cases images adequate for diagnosis and management were obtained with appreciably less contrast medium and a lower radiation dose than in a comparable group of patients using conventional biplane cineangiography. Thus digital subtraction angiography is a viable alternative to biplane cineangiography for children with congenital heart disease.
Full text
PDFImages in this article
Selected References
These references are in PubMed. This may not be the complete list of references from this article.
- Buonocore E., Pavlicek W., Modic M. T., Meaney T. F., O'Donovan P. B., Grossman L. B., Moodie D. S., Yiannikas J. Anatomic and functional imaging of congenital heart disease with digital subtraction angiography. Radiology. 1983 Jun;147(3):647–654. doi: 10.1148/radiology.147.3.6342029. [DOI] [PubMed] [Google Scholar]
- Gootman N., Rudolph A. M., Buckley N. M. Effects of angiographic contrast media on cardiac function. Am J Cardiol. 1970 Jan;25(1):59–65. doi: 10.1016/0002-9149(70)90815-5. [DOI] [PubMed] [Google Scholar]
- Harrington D. P., Boxt L. M., Murray P. D. Digital subtraction angiography: overview of technical principles. AJR Am J Roentgenol. 1982 Oct;139(4):781–786. doi: 10.2214/ajr.139.4.781. [DOI] [PubMed] [Google Scholar]
- Levin A. R., Goldberg H. L., Borer J. S., Rothenberg L. N., Nolan F. A., Engle M. A., Cohen B., Skelly N. T., Carter J. Digital angiography in the pediatric patient with congenital heart disease: comparison with standard methods. Circulation. 1983 Aug;68(2):374–384. doi: 10.1161/01.cir.68.2.374. [DOI] [PubMed] [Google Scholar]
- Martin E. C., Olson A. Radiation exposure to the paediatric patient from cardiac catheterization and angiocardiography. Br J Radiol. 1980 Feb;53(626):100–106. doi: 10.1259/0007-1285-53-626-100. [DOI] [PubMed] [Google Scholar]
- Maxon H. R., Thomas S. R., Saenger E. L., Buncher C. R., Kereiakes J. G. Ionizing irradiation and the induction of clinically significant disease in the human thyroid gland. Am J Med. 1977 Dec;63(6):967–978. doi: 10.1016/0002-9343(77)90552-6. [DOI] [PubMed] [Google Scholar]
- Moodie D. S., Yiannikas J., Gill C. C., Buonocore E., Pavlicek W. Intravenous digital subtraction angiography in the evaluation of congenital abnormalities of the aorta and aortic arch. Am Heart J. 1982 Sep;104(3):628–634. doi: 10.1016/0002-8703(82)90238-1. [DOI] [PubMed] [Google Scholar]
- Shehadi W. H. Adverse reactions to intravascularly administered contrast media. A comprehensive study based on a prospective survey. Am J Roentgenol Radium Ther Nucl Med. 1975 May;124(1):145–152. doi: 10.2214/ajr.124.1.145. [DOI] [PubMed] [Google Scholar]
- Wagner M. L., Singleton E. B., Egan M. E. Digital subtraction angiography in children. AJR Am J Roentgenol. 1983 Jan;140(1):127–133. doi: 10.2214/ajr.140.1.127. [DOI] [PubMed] [Google Scholar]
- Waldman J. D., Rummerfield P. S., Gilpin E. A., Kirkpatrick S. E. Radiation exposure to the child during cardiac catheterization. Circulation. 1981 Jul;64(1):158–163. doi: 10.1161/01.cir.64.1.158. [DOI] [PubMed] [Google Scholar]