Skip to main content
British Heart Journal logoLink to British Heart Journal
. 1977 Oct;39(10):1071–1075. doi: 10.1136/hrt.39.10.1071

Two-dimensional echocardiography with a wide angle (60 degrees) sector scanner.

A B Houston, N L Gregory, A Shaw, D J Wheatley, E N Coleman
PMCID: PMC483372  PMID: 911557

Abstract

A wide angle (60 degrees) sector scanner producing a real-time two-dimensional echocardiogram has been used to examine healthy infants, children, and adults. Its method of use is described and findings from longitudinal and transverse scans are presented. The points of difference between the various types of electronic and mechanical two-dimensional scanning systems are discussed. This equipment minimises problems of chest contact and rib and lung interference and, by providing echocardiograms of high line density from a wide angle, is a suitable real-time two-dimensional scanning system for examining patients of all ages.

Full text

PDF
1074

Images in this article

Selected References

These references are in PubMed. This may not be the complete list of references from this article.

  1. Bom N., Lancée C. T., van Zwieten G., Kloster F. E., Roelandt J. Multiscan echocardiography. I. Technical description. Circulation. 1973 Nov;48(5):1066–1074. doi: 10.1161/01.cir.48.5.1066. [DOI] [PubMed] [Google Scholar]
  2. Griffith J. M., Henry W. L. A sector scanner for real time two-dimensional echocardiography. Circulation. 1974 Jun;49(6):1147–1152. doi: 10.1161/01.cir.49.6.1147. [DOI] [PubMed] [Google Scholar]
  3. Nishimura K., Hibi N., Kato T., Fukui Y., Arakawa T. Real-time observation of cardiac movement and structures in congenital and acquired heart diseases employing high-speed ultrasonocardiotomography. Am Heart J. 1976 Sep;92(3):340–350. doi: 10.1016/s0002-8703(76)80115-9. [DOI] [PubMed] [Google Scholar]
  4. Sahn D. J., Terry R., O'Rourke R., Leopold G., Friedman W. F. Multiple crystal cross-sectional echocardiography in the diagnosis of cyanotic congenital heart disease. Circulation. 1974 Aug;50(2):230–238. doi: 10.1161/01.cir.50.2.230. [DOI] [PubMed] [Google Scholar]
  5. Sahn D. J., Williams D. E., Shackelton S., Friedman W. F. The validity of structure identification for cross-sectional echocardiography. J Clin Ultrasound. 1974 Sep;2(3):201–216. doi: 10.1002/jcu.1870020309. [DOI] [PubMed] [Google Scholar]
  6. Shaw A., Paton J. S., Gregory N. L., Wheatley D. J. A real time 2-dimensional ultrasonic scanner for clinical use. Ultrasonics. 1976 Jan;14(1):35–40. doi: 10.1016/0041-624x(76)90070-6. [DOI] [PubMed] [Google Scholar]
  7. vonRamm O. T., Thurstone F. L. Cardiac imaging using a phased array ultrasound system. I. System design. Circulation. 1976 Feb;53(2):258–262. doi: 10.1161/01.cir.53.2.258. [DOI] [PubMed] [Google Scholar]

Articles from British Heart Journal are provided here courtesy of BMJ Publishing Group

RESOURCES