Abstract
A female child, 10 months of age, weighing 7.2 kg, was catheterised for closure of a patent arterial duct. Aortography was performed in the lateral projection and the minimum diameter of the arterial duct was assessed by comparing it to the size of the catheter. The duct size was estimated between 3 and 3.5 mm at the narrowest point, therefore, it was decided to deliver two 5 mm patent arterial duct coils to avoid placement of an 8 mm coil in this small child. Similar operations were subsequently performed in two further children. Simultaneous delivery of two coils via a single long venous sheath is easy, fast, and safe. This simple and inexpensive procedure can reduce irradiation and anaesthesia time.
Full text
PDF

Images in this article
Selected References
These references are in PubMed. This may not be the complete list of references from this article.
- Hijazi Z. M., Geggel R. L. Transcatheter closure of large patent ductus arteriosus (> or = 4 mm) with multiple Gianturco coils: immediate and mid-term results. Heart. 1996 Dec;76(6):536–540. doi: 10.1136/hrt.76.6.536. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Rigby M. L. Closure of the arterial duct: past, present, and future. Heart. 1996 Dec;76(6):461–462. doi: 10.1136/hrt.76.6.461. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Rosenthal E., Qureshi S. A., Reidy J., Baker E. J., Tynan M. Evolving use of embolisation coils for occlusion of the arterial duct. Heart. 1996 Dec;76(6):525–530. doi: 10.1136/hrt.76.6.525. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Tometzki A. J., Arnold R., Peart I., Sreeram N., Abdulhamed J. M., Godman M. J., Patel R. G., Kitchiner D. J., Bu'Lock F. A., Walsh K. P. Transcatheter occlusion of the patent ductus arteriosus with Cook detachable coils. Heart. 1996 Dec;76(6):531–535. doi: 10.1136/hrt.76.6.531. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Tometzki A., Chan K., De Giovanni J., Houston A., Martin R., Redel D., Redington A., Rigby M., Wright J., Wilson N. Total UK multi-centre experience with a novel arterial occlusion device (Duct Occlud pfm). Heart. 1996 Dec;76(6):520–524. doi: 10.1136/hrt.76.6.520. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Uzun O., Hancock S., Parsons J. M., Dickinson D. F., Gibbs J. L. Transcatheter occlusion of the arterial duct with Cook detachable coils: early experience. Heart. 1996 Sep;76(3):269–273. doi: 10.1136/hrt.76.3.269. [DOI] [PMC free article] [PubMed] [Google Scholar]