Abstract
It is suggested that non-invasive techniques for measuring intracranial pressure should be suitable for use in the unsedated infant and should be capable of measuring pressure continuously. Methods described by other authors are reviewed. After investigation of 18 patients the technique relying upon the pulsation of the fontanelle described by Purin was rejected as being difficult to perform and applicable only in certain patients with large fontanelles. The technique of using a modified Schiotz tonometer was examined but rejected on grounds of inaccuracy, the need to perform the measurement with the infant in a vertical position, and the varying compressibility of the fontanelle. A method for indirectly estimating intracranial pressure using a modified aplanation principle is described, and a comparison of the pressures so measured and needle pressures is reported. The possible uses of a `fontanometer' using the aplanation principle are discussed and a preliminary report given of its use to monitor the changes of intracranial pressure caused by drugs.
Full text
PDFImages in this article
Selected References
These references are in PubMed. This may not be the complete list of references from this article.
- Brett E. M. Measurement of cerebrospinal fluid pressure in infants without puncture. Dev Med Child Neurol. 1966 Apr;8(2):207–210. doi: 10.1111/j.1469-8749.1966.tb01729.x. [DOI] [PubMed] [Google Scholar]
- DAVIDOFF L. M., CHAMLIN M. The "fontanometer"; adaptation of the Schiotz tonometer for the determination of intracranial pressure in the neonatal and early periods of infancy. Pediatrics. 1959 Dec;24:1065–1068. [PubMed] [Google Scholar]
- Guthrie T. C., Dunbar H. S., Karpell B. Ventricular size and chronic increased intracranial venous pressure in the dog. J Neurosurg. 1970 Oct;33(4):407–414. doi: 10.3171/jns.1970.33.4.0407. [DOI] [PubMed] [Google Scholar]
- Hayden P. W., Shurtleff D. B., Foltz E. L. Ventricular fluid pressure recordings in hydrocephalic patients. Arch Neurol. 1970 Aug;23(2):147–154. doi: 10.1001/archneur.1970.00480260053007. [DOI] [PubMed] [Google Scholar]
- Hussey F., Schanzer B., Katzman R. A simple constant-infusion manometric test for measurement of CSF absorption. II. Clinical studies. Neurology. 1970 Jul;20(7):665–680. doi: 10.1212/wnl.20.7.665. [DOI] [PubMed] [Google Scholar]
- Katzman R., Hussey F. A simple constant-infusion manometric test for measurement of CSF absorption. I. Rationale and method. Neurology. 1970 Jun;20(6):534–544. doi: 10.1212/wnl.20.6.534. [DOI] [PubMed] [Google Scholar]
- Lorber J. The use of isosorbide in the treatment of hydrocephalus. Dev Med Child Neurol Suppl. 1972;27:87–93. doi: 10.1111/j.1469-8749.1972.tb09779.x. [DOI] [PubMed] [Google Scholar]
- Martins A. N., Wiley J. K., Myers P. W. Dynamics of the cerebrospinal fluid and the spinal dura mater. J Neurol Neurosurg Psychiatry. 1972 Aug;35(4):468–473. doi: 10.1136/jnnp.35.4.468. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Sibayan R. Q., Begeman P. C., King A. I., Gurdjian E. S., Thomas L. M. Experimental hydrocephalus. Ventricular cerebrospinal fluid pressure and waveform studies. Arch Neurol. 1970 Aug;23(2):165–172. doi: 10.1001/archneur.1970.00480260071010. [DOI] [PubMed] [Google Scholar]