Skip to main content
Journal of Clinical Pathology logoLink to Journal of Clinical Pathology
. 1996 Dec;49(12):1019–1020. doi: 10.1136/jcp.49.12.1019

The order of draw of blood specimens into additive containing tubes not affect potassium and calcium measurements.

A Majid 1, D C Heaney 1, N Padmanabhan 1, R Spooner 1
PMCID: PMC499656  PMID: 9038745

Abstract

The effect of order of draw when taking blood into tubes containing additive was investigated in 47 medical inpatients; 12 of these patients acted as a control group. The samples were analysed in the order in which they were withdrawn. The results of potassium and calcium concentrations did not differ significantly between groups. Manufacturers recommend a specific order of draw when taking blood using vacuum based blood collection systems, which are routinely used in many hospitals. The results of this study, however, show that order of draw has no effect on calcium or potassium concentrations.

Full text

PDF
1019

Selected References

These references are in PubMed. This may not be the complete list of references from this article.

  1. Calam R. R., Cooper M. H. Recommended "order of draw" for collecting blood specimens into additive-containing tubes. Clin Chem. 1982 Jun;28(6):1399–1399. [PubMed] [Google Scholar]