Abstract
Six strains of Haemophilus influenzae were distributed to 417 United Kingdom laboratories who were asked to test susceptibility of the strains to ampicillin, augmentin, tetracycline, chloramphenicol, and trimethoprim and to test for beta lactamase production. Laboratories were also asked to provide details of their methods by completing a questionnaire. The incidence of reports recording sensitive strains as resistant was 8% (ampicillin), 7% (augmentin), 3% (tetracycline), 1% (chloramphenicol), and 12% (trimethoprim). The incidence of reports recording resistant strains as sensitive was 9% (ampicillin), (2% with beta lactamase producing strains, 24% with non-beta lactamase producing strains), 51% (augmentin), 10% (tetracycline), 20% (chloramphenicol), and 3% (trimethoprim). High error rates were associated with several methods or practices. These included use of general purpose growth media rather than susceptibility testing media and failure to add lysed blood to the media when testing trimethoprim susceptibility; standardise the inoculum; use suitable control strains; and the use of high content discs for testing chloramphenicol, tetracycline, and ampicillin.
Full text
PDFSelected References
These references are in PubMed. This may not be the complete list of references from this article.
- Ericsson H. M., Sherris J. C. Antibiotic sensitivity testing. Report of an international collaborative study. Acta Pathol Microbiol Scand B Microbiol Immunol. 1971;217(Suppl):1+–1+. [PubMed] [Google Scholar]
- Harkness R. A., Lund R. J. Cerebrospinal fluid concentrations of hypoxanthine, xanthine, uridine and inosine: high concentrations of the ATP metabolite, hypoxanthine, after hypoxia. J Clin Pathol. 1983 Jan;36(1):1–8. doi: 10.1136/jcp.36.1.1. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Snell J. J., Brown D. F., Gardner P. S. An antibiotic susceptibility testing trial organised as part of the United Kingdom national external microbiological quality assessment scheme. J Clin Pathol. 1982 Nov;35(11):1169–1176. doi: 10.1136/jcp.35.11.1169. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Snell J. J., Brown D. F., Gardner P. S. Comparison of results from two antibiotic susceptibility testing trials that formed part of the United Kingdom national external quality assessment scheme. J Clin Pathol. 1984 Mar;37(3):321–328. doi: 10.1136/jcp.37.3.321. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Snell J. J., De Mello J. V., Gardner P. S. The United Kingdom national microbiological quality assessment scheme. J Clin Pathol. 1982 Jan;35(1):82–93. doi: 10.1136/jcp.35.1.82. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Snell J. J. United Kingdom National External Quality Assessment Scheme for Microbiology. Eur J Clin Microbiol. 1985 Oct;4(5):464–467. doi: 10.1007/BF02014425. [DOI] [PubMed] [Google Scholar]
- Waterworth P. M. Changes in sensitivity testing. J Antimicrob Chemother. 1983 Jan;11(1):1–3. doi: 10.1093/jac/11.1.1. [DOI] [PubMed] [Google Scholar]