Abstract
With the recent advent of accurate orbital volume assessment by computed tomography, a retrospective analysis was made of 31 patients with 'pure' blowout fracture of the orbital floor, managed either surgically or conservatively, to determine whether orbital volume measurement could provide an additional parameter of use in the management of such fractures. There was a significant difference in orbital volume discrepancy between patients managed surgically or conservatively suggesting that this investigation may be of use in decision making on surgical intervention in patients with orbital blowout fractures.
Full text
PDFImages in this article
Selected References
These references are in PubMed. This may not be the complete list of references from this article.
- Ball J. B., Jr Direct oblique sagittal CT of orbital wall fractures. AJR Am J Roentgenol. 1987 Mar;148(3):601–608. doi: 10.2214/ajr.148.3.601. [DOI] [PubMed] [Google Scholar]
- CRAMER L. M., TOOZE F. M., LERMAN S. BLOWOUT FRACTURES OF THE ORBIT. Br J Plast Surg. 1965 Apr;18:171–179. doi: 10.1016/s0007-1226(65)80022-4. [DOI] [PubMed] [Google Scholar]
- Converse J. M. On the treatment of blow-out fractures of the orbit. Plast Reconstr Surg. 1978 Jul;62(1):100–104. doi: 10.1097/00006534-197807000-00016. [DOI] [PubMed] [Google Scholar]
- Converse J. M., Smith B., Obear M. F., Wood-Smith D. Orbital blowout fractures: a ten-year survey. Plast Reconstr Surg. 1967 Jan;39(1):20–36. doi: 10.1097/00006534-196701000-00002. [DOI] [PubMed] [Google Scholar]
- Dutton J. J. Management of blow-out fractures of the orbital floor. Surv Ophthalmol. 1991 Jan-Feb;35(4):279–280. doi: 10.1016/0039-6257(91)90048-k. [DOI] [PubMed] [Google Scholar]
- Emery J. M., Noorden G. K., Sclernitzauer D. A. Orbital floor fractures: long-term follow-up of cases with and without surgical repair. Trans Am Acad Ophthalmol Otolaryngol. 1971 Jul-Aug;75(4):802–812. [PubMed] [Google Scholar]
- Fitzsimons R., White J. Functional scoring of the field of binocular single vision. Ophthalmology. 1990 Jan;97(1):33–35. doi: 10.1016/s0161-6420(90)32631-3. [DOI] [PubMed] [Google Scholar]
- Gholkar A., Gillespie J. E., Hart C. W., Mott D., Isherwood I. Dynamic low-dose three-dimensional computed tomography: a preliminary study. Br J Radiol. 1988 Dec;61(732):1095–1099. doi: 10.1259/0007-1285-61-732-1095. [DOI] [PubMed] [Google Scholar]
- Gilbard S. M., Mafee M. F., Lagouros P. A., Langer B. G. Orbital blowout fractures. The prognostic significance of computed tomography. Ophthalmology. 1985 Nov;92(11):1523–1528. doi: 10.1016/s0161-6420(85)33826-5. [DOI] [PubMed] [Google Scholar]
- Manson P. N., Grivas A., Rosenbaum A., Vannier M., Zinreich J., Iliff N. Studies on enophthalmos: II. The measurement of orbital injuries and their treatment by quantitative computed tomography. Plast Reconstr Surg. 1986 Feb;77(2):203–214. [PubMed] [Google Scholar]
- Putterman A. M., Stevens T., Urist M. J. Nonsurgical management of blow-out fractures of the orbital floor. Am J Ophthalmol. 1974 Feb;77(2):232–239. doi: 10.1016/0002-9394(74)90679-5. [DOI] [PubMed] [Google Scholar]
- Weiss R. A., Haik B. G., Saint-Louis L. A., Ellsworth R. M. Advanced diagnostic imaging techniques in ophthalmology. Adv Ophthalmic Plast Reconstr Surg. 1987;6:207–263. [PubMed] [Google Scholar]
- Wilkins R. B., Havins W. E. Current treatment of blow-out fractures. Ophthalmology. 1982 May;89(5):464–466. doi: 10.1016/s0161-6420(82)34767-3. [DOI] [PubMed] [Google Scholar]