Abstract
The use of the Mersilene mesh sling brow suspension procedure for the correction of severe blepharoptosis in 76 lids of 54 patients is presented. After a median follow up of 20 months functional and cosmetic results and complications were evaluated. The method is considered to be an alternative for those cases not primarily suitable for autogenous fascia lata brow suspension.
Full text
PDFSelected References
These references are in PubMed. This may not be the complete list of references from this article.
- ADLER R. H., FIRME C. N. Use of pliable synthetic mesh in the repair of hernias and tissue defects. Surg Gynecol Obstet. 1959 Feb;108(2):199–206. [PubMed] [Google Scholar]
- Adenis J. P., Lebraud P., Mathon M. Utilisation du PFTE (Goretex) dans la suspension palpébro-frontale pour le ptosis. J Fr Ophtalmol. 1987;10(10):607–609. [PubMed] [Google Scholar]
- Beaconsfield M., Walker J. W., Collin J. R. Visual development in the blepharophimosis syndrome. Br J Ophthalmol. 1991 Dec;75(12):746–748. doi: 10.1136/bjo.75.12.746. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Beyer C. K., Albert D. M. The use and fate of fascia lata and sclera in ophthalmic plastic and reconstructive surgery. Ophthalmology. 1981 Sep;88(9):869–886. doi: 10.1016/s0161-6420(81)80001-2. [DOI] [PubMed] [Google Scholar]
- Billet E. Bovine fascia lata in ptosis surgery. Am J Ophthalmol. 1968 Apr;65(4):561–571. doi: 10.1016/0002-9394(68)93875-0. [DOI] [PubMed] [Google Scholar]
- Bodian M. Repair of ptosis using human sclera. Am J Ophthalmol. 1968 Mar;65(3):352–358. doi: 10.1016/0002-9394(68)93084-5. [DOI] [PubMed] [Google Scholar]
- Broughton W. L., Matthews J. G., 2nd, Harris D. J., Jr Congenital ptosis. Results of treatment using lyophilized fascia lata for frontalis suspensions. Ophthalmology. 1982 Nov;89(11):1261–1266. doi: 10.1016/s0161-6420(82)34645-x. [DOI] [PubMed] [Google Scholar]
- CRAWFORD J. S. Repair of ptosis using frontalis muscle and fascia lata. Trans Am Acad Ophthalmol Otolaryngol. 1956 Sep-Oct;60(5):672–678. [PubMed] [Google Scholar]
- Cole M. D., O'Connor G. M., Raafai F., Willshaw H. E. A new synthetic material for the brow suspension procedure. Br J Ophthalmol. 1989 Jan;73(1):35–38. doi: 10.1136/bjo.73.1.35. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Crawford J. S. Fascia lata: its nature and fate after implantation and its use in ophthalmic surgery. Trans Am Ophthalmol Soc. 1968;66:673–745. [PMC free article] [PubMed] [Google Scholar]
- Crawford J. S. Repair of ptosis using frontalis muscle and fascia lata: a 20-year review. Ophthalmic Surg. 1977 Aug;8(4):31–40. [PubMed] [Google Scholar]
- Downes R. N., Collin J. R. The Mersilene mesh ptosis sling. Eye (Lond) 1990;4(Pt 3):456–463. doi: 10.1038/eye.1990.58. [DOI] [PubMed] [Google Scholar]
- Downes R. N., Collin J. R. The Mersilene mesh sling--a new concept in ptosis surgery. Br J Ophthalmol. 1989 Jul;73(7):498–501. doi: 10.1136/bjo.73.7.498. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Fox S. A. A new frontalis skin sling for ptosis. Am J Ophthalmol. 1968 Mar;65(3):359–362. doi: 10.1016/0002-9394(68)93085-7. [DOI] [PubMed] [Google Scholar]
- Fox S. A. Complications of frontalis sling surgery. Am J Ophthalmol. 1967 Apr;63(4):758–762. doi: 10.1016/0002-9394(67)91302-5. [DOI] [PubMed] [Google Scholar]
- Goldberger S., Conn H., Lemor M. Double rhomboid silicone rod frontalis suspension. Ophthal Plast Reconstr Surg. 1991;7(1):48–53. doi: 10.1097/00002341-199103000-00006. [DOI] [PubMed] [Google Scholar]
- Harrad R. A., Graham C. M., Collin J. R. Amblyopia and strabismus in congenital ptosis. Eye (Lond) 1988;2(Pt 6):625–627. doi: 10.1038/eye.1988.115. [DOI] [PubMed] [Google Scholar]
- Katowitz J. A. Frontalis suspension in congenital ptosis using a polyfilament, cable-type suture. Arch Ophthalmol. 1979 Sep;97(9):1659–1663. doi: 10.1001/archopht.1979.01020020227009. [DOI] [PubMed] [Google Scholar]
- Kemp E. G., James C. R., Collin J. R. Brow suspension in the management of ptosis: an analysis of over 100 cases. Trans Ophthalmol Soc U K. 1986;105(Pt 1):84–87. [PubMed] [Google Scholar]
- Saunders R. A., Grice C. M. Early correction of severe congenital ptosis. J Pediatr Ophthalmol Strabismus. 1991 Sep-Oct;28(5):271–273. doi: 10.3928/0191-3913-19910901-09. [DOI] [PubMed] [Google Scholar]
- Tillett C. W., Tillett G. M. Silicone sling in the correction of ptosis. Am J Ophthalmol. 1966 Sep;62(3):521–523. doi: 10.1016/0002-9394(66)91334-1. [DOI] [PubMed] [Google Scholar]
- Wagner R. S., Mauriello J. A., Jr, Nelson L. B., Calhoun J. H., Flanagan J. C., Harley R. D. Treatment of congenital ptosis with frontalis suspension: a comparison of suspensory materials. Ophthalmology. 1984 Mar;91(3):245–248. doi: 10.1016/s0161-6420(84)34298-1. [DOI] [PubMed] [Google Scholar]
- Wilson M. E., Johnson R. W. Congenital ptosis. Long-term results of treatment using lyophilized fascia lata for frontalis suspensions. Ophthalmology. 1991 Aug;98(8):1234–1237. [PubMed] [Google Scholar]