The challenges with the validation of research antibodies

Jan LA Voskuil 1,a
PMCID: PMC5333605  PMID: 28357047

Abstract

This article further discusses the reproducibility crisis in biomedical science and how poor conduct of commercial antibodies contribute to this. In addition, the way quality data are presented on product sheets by antibody vendors is scrutinized. The article proposes that there is a distinction between testing data and validation data, and special attention is asked for consistency between batches and aliquots. Moreover, the article separates the specifics, such as formulation, antigen and price, from the specifics on performance. Finally, a two-tier approach is discussed, enabling scientists to anticipate how an antibody is likely to perform when repeated purchases are required.

Keywords: Antibodies, validation, reproducibility, conformance

Introduction

In the scientific community, there is growing attention to the quality of commercial research antibodies, particularly since the recent intensified publications on the crisis of reproducibility 16. Although some papers have already addressed the lack of quality in the antibody market much earlier 710, since a link was made between lack of scientific reproducibility and antibody conduct 1113, more efforts were made to bring all stakeholders in the research antibody market together to move forward. Such efforts resulted in online discussions ( https://www.protocols.io/groups/gbsi-antibody-validation-online-group), publications on validation 1417 and two international meetings 1820. Everyone agreed that to some extent bad quality antibodies may contribute to lack of scientific progress and that something had to be done to remove such blame from the industries. The strong message is that antibodies need proper validation first before being used in scientific research. A few large vendors have commenced with exhaustive validation for some of their products, but the investment for validation of each individual product is very high and such efforts are not commercially attractive enough to apply for all catalogue items when the size of the catalogue is in the hundreds of thousands 21. Besides, despite all the good intensions and large investments in the industry, the approach of exhaustive validation is not the complete answer to the problem. When it comes to antibody validation there are some practical difficulties that are not always appreciated, or they are underestimated if not totally ignored. This article aims to create clarity in the practical issues that directly affects the quality and performance of research antibodies, even when a product has successfully gone through an exhaustive validation process.

Basic principles of validation

There is a fundamental difference between testing an antibody in a certain application, and validation. The former is put in practice by most of us (both vendors/manufacturers and research scientists). Until recently testing with a positive result was more than adequate to pass a product for the market and to persuade researchers to buy the tested antibody. For example, when an antibody was tested in Immunohistochemistry (IHC) and there was a signal, the vendor would go ahead adding the data to the product sheet and adding IHC to the tested applications. Any scientist would not think otherwise than to assume this antibody was fit for IHC and to buy the product, especially when the brand is large and deemed reliable. These times are over. Currently a signal needs to be in the right place and in a relevant tissue to be credible.

Validation goes way beyond mere testing. Here, we first consider how the antibody is commonly used. For example, a CD4 antibody is most likely being used in Flow Cytometry (FC). Then it follows that this antibody is primarily tested in FC and not in Western Blot (WB) or IHC. However, for proper validation the signal needs to be specific and selective; that is at the maximal dilution for good signal in the right cell type, there should be hardly any signal in the wrong cell types. Hence, validation always involves comparison between expressing and non-expressing cells or tissues at identical antibody dilutions. A CD4 antibody is validated in FC when it lifts out a proportionate sub population from all T-cells (the proportion of CD4+ T cells). The way to do this is to have all T cells selected from the buffy coat first by a generic T cell marker antibody (formerly and fully validated for this purpose) and have the signal of CD4 label related to the total T cell signal quantified. Ideally there is another validated CD4 antibody to compare with and to confirm that the observed proportion of CD4 signal relative to the total T cell signal is consistent across the two CD4 antibodies. A commonly used format showing a stain distribution of a single cell line with a peak away from background is not evidence of specificity. For IHC or WB, again comparison between expressing and non-expressing cells/tissues is required for proper validation. An antibody fit for and validated in WB will not automatically pass in IHC or FC though. The notion in the literature 7 that every antibody needs first validation in WB before moving on to the required assay is flawed and entails the risk of losing out on precious FC antibodies that will never work in WB or IHC.

Conformity of validated antibodies in batches and aliquots

In an ideal world, all antibodies on offer are fully validated for the applications on demand by the market. Although we are far away from this reality, all vendors and manufacturers are currently working very hard to reach this goal. Consequently, increasing amounts of fully validated products are emerging daily. However, this is not the end of the tragedy. As discussed thoroughly in multimedia and to a smaller extent in the literature 8, 14, the antibodies on sale come in batches or lots. And there will be variabilities from batch to batch or from lot to lot. This is true for monoclonal antibodies (especially when sold in an undefined formulation, such as culture media or ascites), but to a much larger extent this is the case for polyclonal antibodies (especially for undefined formulations, such as serum or plasma, but also for antibodies raised to the entire protein and with an undefined epitope). Therefore, the test/validation results shown on the product sheet will no longer be representative after the batch or lot has been replaced by its successor, unless the data have been reproduced with the new batch/lot.

There is confusion about the terms batch and lot. They are generally used interchangeably. There is a strong case though to distinguish batches from aliquots: It is recommended to have a batch defined by the harvest and purification, while an aliquot is defined by the place and the day a stock vial is split. The term lot is best avoided to keep the separation between batch and aliquot unambiguous. This article proposes to have this principle copied worldwide. The functionality of this distinction is that any non-conformity can be easily traced back either to inactivation by storage or transit (then a different aliquot with a different history will show conformity again), or to a bad purification or bad production (in which case the entire batch will be withdrawn from the market and be replaced by a new batch).

It is recommended to have transparency regarding batches and aliquots. The batch codes are preferred to be visible on the product sheet, while both the batch code and aliquot coding is required to be specified on the label of every vial.

Responsibility of testing and validation

As soon as a purchased antibody has arrived, it is the responsibility of the scientist to make sure the product arrived in proper conditions. It would be good practice to start reproducing the data as described on the product sheet to make sure the antibody shows conformity. This should be done before splitting the product into aliquots and storage in a (non-cycling) freezer. This way a non-conforming product can be returned or the specifics on the label can be forwarded to the vendor together with the complaint. Any self-respecting vendor will either replace or refund when a product is non-conformant. Once the antibody has demonstrated its integrity, it is time to use it in the intended experiments. No matter the high quality of data shown on the product sheet, every scientist must validate the antibody in the assay and biological material of interest. It is not evident at all that a positively tested antibody on liver or kidney is going to work on fibroblast or neuronal cell lines. In addition, one should not assume that positive result on a lysate of a neuroblast cell line in WB means that the scientist is going to get the antibody to work in lysates of different brain regions. So, the scientist is primarily responsible for the validation of the purchased antibody in the very defined conditions of the experiments to be done. A lot of precious time and biological research material is saved by following the above steps before using the purchased antibody for the intended experiments. Most vendors and manufacturers will most likely not go much further than confirmation of their products in one or a few assay types in one or a few cell types. Vendor and scientist will achieve a shared responsibility when they develop a mutual understanding and respect for each other’s objectives 21.

Deciding factors on the product of choice

Given the size and complexity of the research antibody market, the best way to decide which antibody to pick is to consider a two-tier approach. The first tier considers the specifications of the product regardless of its performance (see Table 1). The scientist needs to decide if a mono-specific antibody is required (which may be essential for certain assays when dependent on repeat purchases), and how the product is formulated. These considerations need to be weighed against the clone/batch specifications, presence of quality data and price. The second tier considers the claimed performance, as specified on the product sheet. Here, the scientific integrity of the quality data come into play (see Table 2). There is an important distinction to be made by the scientist if the antibody is required for native conditions or for non-native conditions. Antibodies confirmed in native assays may not work in non-native assays and vice versa. The extent of quality data, as described on the product sheet, is incrementally listed for each of the most common assay types.

Table 1. Tier 1: Performance-independent specifications.

Overview of variety on performance-independent specification visible on the vendor’s product sheet. WB: Western Blot.

Antigen Clone/batch
specification
Quality data to back
up application codes
Formulation Quantity/price
Entire protein/large
part of protein
Nothing specified No data and no
literature references
Serum, culture
supernatant, ascitus
No quantity, ask for
quotation
Epitope/short peptide
sequence, undisclosed
Clone # specified No data, but proven
record through literature
IgG-fraction Good for # WBs
Epitope/short peptide
sequence, disclosed
Batch available on
request
Data not batch-specific Affinity purified without
specification
Volume
Batch on product
sheet/cat #-spec
Data batch-specific but
not specified
Protein A or G purified Specified IgG in ug
or mg
Data batch-specific and
specified
Antigen affinity purified

Table 2. Tier 2: Performance specifications.

Overview of variety of performance specifications visible on the vendor’s product sheet. NB: Comparison between wildtype and knock-out is in all cases the best validation and is not incorporated in this schedule.

Cell type, a cell line or a cell type from primary culture or a cell type within a mixture of types/tissue; KD: Knock-Down by induced siRNA expression; RT-PCR, quantitative data demonstrated the levels of mRNA in KD relative to wildtype levels; WB: Western Blot; IP: Immunoprecipitation.

Native conditions
ELISA
On coated purified peptide
On coated purified entire protein
Sandwich in buffer with purified protein for calibration
Sandwich in natural matrix, spiked with purified protein for calibration
Sandwich in natural matrix comparing naturally low and high level samples
Flow Cytometry
Irrelevant cell type, one ab only and without any controls
Irrelevant cell type, one ab only and with isotype control
Relevant cell type, one Ab only and without any controls
Relevant cell type, one Ab only and with isotype control
Relevant cell type mixed with a non-expressing cell type and co-stained with a
sharing marker
Mixed cell types with a subpopulation stained by a shared marker, and part of it
stained by research antibody
Immunocytochemistry
Irrelevant cell type without comparisons
Irrelevant cell type compared with KD but without RT-PCR data
Irrelevant cell type compared with KD and with RT-PCR data
Relevant cell type without comparisons
Relevant cell type compared with KD but without RT-PCR data
Relevant cell type compared with KD and with RT-PCR data
Non-native conditions
Western Blot
WB on overexpression only
WB on irrelevant cell type at endogenous levels
WB on relevant cell type but wrong band(s)
WB on relevant cell type with correct band(s), but no further controls
WB on relevant cell type with correct band(s), and with controls:
Immunoprecipitation
IP without proper controls, detected by WB with same antibody
IP without proper controls, detected by WB with a different antibody
IP without proper controls, detected directly through radiogram or fluorescence
IP comparing with and without primary, detected by WB with same antibody
IP comparing with isotype, detected by WB with same antibody (using light chain
or heavy chain detected by secondary as loading control)
IP comparing with and without primary, detected by WB with a different antibody
IP comparing with isotype, detected by WB with a different antibody (not having
loading control)
IP comparing with isotype, detected by WB with a different antibody (but having
loading control by other means)
Immunohistochemistry
Unclear cellular location staining on cancerous tissue only
Irrelevant tissues and with unclear cellular location staining
Irrelevant tissues but with clear and correct cellular location staining
Relevant tissues, but unclear cellular location staining
Relevant tissues, with clear cellular location staining

The two tables highlight a sliding scale of quality specifications currently offered on many catalogues worldwide. We should not dismiss vendors and manufacturers for not having the highest level of quality specifications available for each single product because of the practical restrictions coming with the size and resources of every company 21. It is down to the scientist to find their way, and in the meanwhile the manufacturers and vendors do their utmost to deserve the scientist’s trust in their quality. Nonetheless, Table 2 demonstrates that many product sheets show inadequate information and are not yet meeting current requirements in the market. There will be increasing demand for testing in biological relevant cell types/tissues or when gene expression allows to have comparative data to validate the observed signals against negative controls.

In addition, product sheets of many peptide-generated antibodies show an ELISA titre to the immunizing peptide, but they usually claim ELISA in the tested application list, which is deceiving because this claim is read as any type of ELISA involving detection of entire protein. When the antibody was merely tested on peptide-coated micro-wells, it would be better to claim peptide-ELISA as the tested application rather than ELISA. We do see more often the application code IHC better specified as IHC-p (paraffin-embedded) and IHC-fr (frozen sections). Similarly, we could use ELISA-p (peptide or protein coated wells) and ELISA-s (sandwich).

Reproducibility and specificity

Any proper validation must include evidence of robustness from batch to batch. External factors, such as exposure to freeze/thaw cycles, and to radiation or extreme heat, will affect the integrity of the antibody. An inactivated aliquot may show either lack of signal, or non-specific signal. Batch variations are subject to variations from animal to animal and from purification to purification. It is worth mentioning that undefined formulations, as described in Table 1 column 4, will have a profound effect on the reproducibility from batch to batch and needs serious consideration especially by assay/kit developers who depend on long term supply of product with identical characteristics from order to order. Antibodies with a defined epitope/immunizing peptide are intrinsically more robust compared to antibodies raised to entire proteins because the limited size of the antigen increases the chance of reproducible characteristics 8. This principle can only be overruled when large amounts of animals are immunized with the same entire protein and their antibodies are pooled together to reach a gold standard. However, potential cross-reactivity to related other proteins needs to be considered as well. This is not possible for monoclonal antibodies without known epitope mapping, and in such cases validation must include testing of cross-reactivity directly to such related proteins.

Discussion

The considerations set out above can be used as a starting point to generate scoring systems. Many vendors are already doing this. However, research scientists remain unaware of such scoring as they are used for internal purposes only. Although such practice will ultimately lead to a much higher quality product on the market, for the moment there is a need for research scientists and assay developers to find their way when looking for that specific antibody fit for their special set-up. Up to this point, they are reliant on cited literature and the reputation of the vendor. However, because of exchange of products across catalogues 8, 20, a situation is created that it is no longer evident from the product sheet if the antibody is offered by the original manufacturer and if the associated quality data is still representative for the current batch on sale. In addition, each large catalogue has several antibodies to the same protein. This makes the choice for the scientist difficult, especially when the cited literature does not specify the catalogue number, and the manufacturer will not be able to tell which one of their products was used for the experiments shown in that paper. This omission has been recognized and publishers are no longer expected to accept a paper without the catalogue numbers of the antibodies used. Therefore, any guidance industries can provide to facilitate biomedical research in finding the right antibody for the specific needs would be more than welcome. In the meanwhile, one is dependent on advice from individual insiders of the industries as they know all relevant details that may not be visible by the public. Such advisers will be best equipped to sift out the best candidate antibodies from the different catalogues for initial testing, followed by proper validation.

Funding Statement

The author(s) declared that no grants were involved in supporting this work.

[version 1; referees: 4 approved]

References

  • 1. Prinz F, Schlange T, Asadullah K: Believe it or not: how much can we rely on published data on potential drug targets? Nat Rev Drug Discov. 2011;10(9):712. 10.1038/nrd3439-c1 [DOI] [PubMed] [Google Scholar]
  • 2. Begley CG, Ellis LM: Drug development: Raise standards for preclinical cancer research. Nature. 2012;483(7391):531–533. 10.1038/483531a [DOI] [PubMed] [Google Scholar]
  • 3. Ioannidis JP: Why Most Clinical Research Is Not Useful. PLoS Med. 2016;13(6):e1002049. 10.1371/journal.pmed.1002049 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 4. Nosek BA, Errington TM: Making sense of replications. eLife. 2017;6: pii: e23383. 10.7554/eLife.23383 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 5. Baker M, Dolgin E: Cancer reproducibility project releases first results. Nature. 2017;541(7637):269–270. 10.1038/541269a [DOI] [PubMed] [Google Scholar]
  • 6. Kaiser J: BIOMEDICAL RESEARCH. Calling all failed replication experiments. Science. 2016;351(6273):548. 10.1126/science.351.6273.548 [DOI] [PubMed] [Google Scholar]
  • 7. Bordeaux J, Welsh A, Agarwal S, et al. : Antibody validation. Biotechniques. 2010;48(3):197–209. 10.2144/000113382 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 8. Voskuil J: Commercial antibodies and their validation [version 2; referees: 3 approved]. F1000Res. 2014;3:232. 10.12688/f1000research.4966.2 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 9. Bradbury A, Plückthun A: Reproducibility: Standardize antibodies used in research. Nature. 2015;518(7537):27–29. 10.1038/518027a [DOI] [PubMed] [Google Scholar]
  • 10. Roncador G, Engel P, Maestre L, et al. : The European antibody network's practical guide to finding and validating suitable antibodies for research. MAbs. 2016;8(1):27–36. 10.1080/19420862.2015.1100787 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 11. Baker M: Reproducibility crisis: Blame it on the antibodies. Nature. 2015;521(7552):274–276. 10.1038/521274a [DOI] [PubMed] [Google Scholar]
  • 12. Baker M: Antibody anarchy: A call to order. Nature. 2015;527(7579):545–551. 10.1038/527545a [DOI] [PubMed] [Google Scholar]
  • 13. Weller MG: Quality issues of research antibodies. Anal Chem Insights. 2016;11:21–27. 10.4137/ACI.S31614 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 14. Pauly D, Hanack K: How to avoid pitfalls in antibody use [version 1; referees: 2 approved]. F1000Res. 2015;4:691. 10.12688/f1000research.6894.1 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 15. Rizner TL, Sasano H, Choi MH, et al. : Recommendations for description and validation of antibodies for research use. J Steroid Biochem Mol Biol. 2016;156:40–42. 10.1016/j.jsbmb.2015.11.021 [DOI] [PubMed] [Google Scholar]
  • 16. Freedman LP, Gibson MC, Bradbury AR, et al. : [Letter to the Editor] The need for improved education and training in research antibody usage and validation practices. Biotechniques. 2016;61(1):16–18. 10.2144/000114431 [DOI] [PubMed] [Google Scholar]
  • 17. Uhlen M, Bandrowski A, Carr S, et al. : A proposal for validation of antibodies. Nat Methods. 2016;13(10):823–827. 10.1038/nmeth.3995 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 18. Freedman LP: GBSI Workshop Report: Antibody Validation: Strategies, Policies, and Practices.2016. Reference Source [Google Scholar]
  • 19. Visk DA: Antibody validation stakeholders speak. Gen. 2016;36(21): 1, 10,12–13. 10.1089/gen.36.21.01 [DOI] [Google Scholar]
  • 20. Freedman LP: The drive for antibody standards-Time to herd the cats. Gen. 2016;36 Reference Source [Google Scholar]
  • 21. Li J: A scientific crisis that starts in the market, not the lab. Sci Am. 2016. Reference Source [Google Scholar]
F1000Res. 2017 Mar 16. doi: 10.5256/f1000research.11700.r20350

Referee response for version 1

Simon Glerup 1

This opinion article makes an important contribution to the ongoing and growing discussion of the use of antibodies in research. The main point is that validation goes beyond mere testing and that when selecting an antibody it is of critical importance for scientists to consider the data provided by the manufacturer in the light of the actual experiment it is intended for. This includes considerations of the relevant tissue, cell type and technique as well as the use of proper positive and negative controls.

Minor comments:

  1. I strongly agree with Referee 2 regarding clarification of the statement ”Antibodies with a defined epitope / immunizing peptide are intrinsically more robust compared to antibodies raised to the entire proteins because the limited size of the antigen increases the chance of reproducible characteristics”. Such statement needs to be accompanied by references to actual data showing this. The current reference 8 is a review.

  2. I consider the sentence “and in the meanwhile the manufacturers and vendors do their utmost to deserve the scientist’s trust in their quality” highly subjective. This may be true in certain cases but I do not think that this can be extended to describe the behavior of the entire industry.

I have read this submission. I believe that I have an appropriate level of expertise to confirm that it is of an acceptable scientific standard.

F1000Res. 2017 Mar 6. doi: 10.5256/f1000research.11700.r20349

Referee response for version 1

Michael G Weller 1

This article is a valuable and welcome contribution to the ongoing discussion of antibody quality. The suggestion of a two-tier approach is helpful to distinguish between simple descriptive data and the validation of an antibody for a specified application.

For an updated article some minor changes should be considered:

  1. Validation is a very old concept in analytical chemistry and therefore, some definitions have already emerged and many regulations and guidelines, e.g. Thompson et al. 1, have been put into effect. Validations of antibody-based methods should make use of these established and proven approaches and should be seen in this context.

  2. In Table 1 the declaration of "Specified IgG in µg or mg" should be discussed briefly, since only in very rare cases the relevant amount has been determined properly. Either non-specific IgG (e.g. antibodies based on ascites) and IgG of a different species (such as bovine IgG) may contaminate the product. In many cases, only the protein content was determined with a semiquantitative spectrophotometric method.

  3. "Comparison between wildtype and knock-out is in all cases the best validation and is not incorporated in this schedule." I want to mention that there are research antibodies against non-proteinaceous targets, which can not be validated this way. Furthermore, in the case of chemically defined antigens (e.g. peptides), the use of LC-MS/MS is perhaps the most powerful approach to validate an antibody-based method.

  4. "This omission has been recognized and publishers are no longer expected to accept a paper without the catalogue numbers of the antibodies used." I do not think that a catalogue number is sufficient for this purpose. A clone number or a real antibody ID would be much better to make an antibody fully traceable 2.

I have read this submission. I believe that I have an appropriate level of expertise to confirm that it is of an acceptable scientific standard.

References

  • 1. Thompson M, Ellison S, Wood R: Harmonized guidelines for single-laboratory validation of methods of analysis (IUPAC Technical Report). Pure and Applied Chemistry.2002;74(5) : 10.1351/pac200274050835 10.1351/pac200274050835 [DOI] [Google Scholar]
  • 2. Weller MG: Quality Issues of Research Antibodies. Anal Chem Insights.2016;11: 10.4137/ACI.S31614 21-7 10.4137/ACI.S31614 [DOI] [PMC free article] [PubMed] [Google Scholar]
F1000Res. 2017 Mar 1. doi: 10.5256/f1000research.11700.r20353

Referee response for version 1

Fridtjof Lund-Johansen 1

The author provides a good overview of current issues with antibody validation. His proposal for a tiered approach to validation is well in line with suggestions from a recent workshop organized by the Global Biological Standards Institute (GBSI) 1 and also with published guidelines from the International Working Group on Antibody Validation (IWGAV) 2. My main comment relates to the choice of controls.

The author explains that "validation always involves comparison between expressing and non-expressing cells or tissues at identical antibody dilutions". In fact, reputable antibody manufacturers rarely show negative controls in their product specification sheets. This is not surprising since there is no comprehensive and definitive source of information about the distribution of proteins in tissues, cells or subcellular compartments. There are now precise maps for the transcriptome, and some researchers argue that mRNA levels are predictive of protein abundance 3 , 4 , 5 , 6. However, published data do not provide a definitive answer to this question, so this remains a controversial issue. In my view, the author should discuss the problems associated with finding bona-fide negative controls for application-specific antibody validation.

I have read this submission. I believe that I have an appropriate level of expertise to confirm that it is of an acceptable scientific standard.

References

  • 1. Baker M: Biologists plan scoring system for antibodies. Nature.2016; 10.1038/nature.2016.20712 10.1038/nature.2016.20712 [DOI] [Google Scholar]
  • 2. Uhlen M, Bandrowski A, Carr S, Edwards A, Ellenberg J, Lundberg E, Rimm DL, Rodriguez H, Hiltke T, Snyder M, Yamamoto T: A proposal for validation of antibodies. Nat Methods.2016;13(10) : 10.1038/nmeth.3995 823-7 10.1038/nmeth.3995 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 3. Uhlén M, Fagerberg L, Hallström BM, Lindskog C, Oksvold P, Mardinoglu A, Sivertsson Å, Kampf C, Sjöstedt E, Asplund A, Olsson I, Edlund K, Lundberg E, Navani S, Szigyarto CA, Odeberg J, Djureinovic D, Takanen JO, Hober S, Alm T, Edqvist PH, Berling H, Tegel H, Mulder J, Rockberg J, Nilsson P, Schwenk JM, Hamsten M, von Feilitzen K, Forsberg M, Persson L, Johansson F, Zwahlen M, von Heijne G, Nielsen J, Pontén F: Proteomics. Tissue-based map of the human proteome. Science.2015;347(6220) : 10.1126/science.1260419 1260419 10.1126/science.1260419 [DOI] [PubMed] [Google Scholar]
  • 4. Melé M, Ferreira PG, Reverter F, DeLuca DS, Monlong J, Sammeth M, Young TR, Goldmann JM, Pervouchine DD, Sullivan TJ, Johnson R, Segrè AV, Djebali S, Niarchou A., GTEx Consortium, Wright FA, Lappalainen T, Calvo M, Getz G, Dermitzakis ET, Ardlie KG, Guigó R: Human genomics. The human transcriptome across tissues and individuals. Science.2015;348(6235) : 10.1126/science.aaa0355 660-5 10.1126/science.aaa0355 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 5. Wilhelm M, Schlegl J, Hahne H, Gholami AM, Lieberenz M, Savitski MM, Ziegler E, Butzmann L, Gessulat S, Marx H, Mathieson T, Lemeer S, Schnatbaum K, Reimer U, Wenschuh H, Mollenhauer M, Slotta-Huspenina J, Boese JH, Bantscheff M, Gerstmair A, Faerber F, Kuster B: Mass-spectrometry-based draft of the human proteome. Nature.2014;509(7502) : 10.1038/nature13319 582-7 10.1038/nature13319 [DOI] [PubMed] [Google Scholar]
  • 6. Edfors F, Danielsson F, Hallström BM, Käll L, Lundberg E, Pontén F, Forsström B, Uhlén M: Gene-specific correlation of RNA and protein levels in human cells and tissues. Mol Syst Biol.2016;12(10) :883 [DOI] [PMC free article] [PubMed] [Google Scholar]
F1000Res. 2017 Feb 24. doi: 10.5256/f1000research.11700.r20351

Referee response for version 1

Alison H Banham 1

This article is a valuable contribution to the ongoing discussion regarding the importance of using properly validated antibodies to undertake robust and reproducible scientific research. The article distinguishes antibody testing, in which reactivity is seen using a specific technique, from validation, where specificity is observed using the appropriate positive and negative controls, and outlines the information provided on commercial product sheets. This article addresses key practical issues that can arise during production, storage, and shipping that can affect the quality of an antibody, even when the reagent has been well validated. Furthermore, the author proposes that distinguishing and identifying batch and aliquot information is adopted universally.

An interesting point arising from reading this article is that despite the mention of using two independent antibodies to the target antigen to validate flow cytometry data (in the example using CD4), this information does not appear frequently on the performance specifications from vendors’ product sheets (Table 2), the exception being for immunoprecipitation. The lack of availability of comparative data (same experiment and biological samples) for multiple antibodies makes it difficult to identify the most effective reagent. It would be helpful if product sheets could display comparative data from suppliers having multiple antibodies to the same antigen. While researchers might still need to purchase another antibody, if they wished to compare the best from different manufacturers, having supportive data using an independent antibody significantly strengthens scientific conclusions.

Minor comments

  1. It might be useful for more inexperienced researchers to highlight in Table 2 what level of information is considered to be inadequate.

  2. The statement that “Antibodies with a defined epitope/immunizing peptide are intrinsically more robust compared to antibodies raised to entire proteins because the limited size of the antigen increases the chance of reproducible characteristics” would benefit from further clarification. While this is true for polyclonals, a monoclonal antibody raised against an entire protein is as robust and reproducible as one recognising an immunizing peptide, as both will bind a single epitope.

I have read this submission. I believe that I have an appropriate level of expertise to confirm that it is of an acceptable scientific standard.


Articles from F1000Research are provided here courtesy of F1000 Research Ltd

RESOURCES