Abstract
Silver nanoparticles (Ag NPs) are increasingly used in biomedical applications because of their large antimicrobial spectrum. Data in the literature on the ability of Ag NPs to perform their desired function without eliciting undesirable effects on blood elements are very limited and contradictory. We studied the impact of Ag NPs on erythrocyte integrity, platelet function and blood coagulation. Erythrocyte integrity was assessed by spectrophotometric measurement of haemoglobin release. Platelet adhesion and aggregation was determined by light transmission aggregometry and scanning electron microscopy. The calibrated thrombin generation test was used to study the impact on coagulation cascade. We demonstrated that Ag NPs induced haemolysis. They also increase platelet adhesion without having any impact on platelet aggregation. Finally, they also had procoagulant potential. Bringing all data from these tests together, the no observed effect concentration is 5 μg/mL.
Keywords: Silver Nanoparticles, Red Blood Cells, Platelets, Coagulation
1. Introduction
Silver has been used in medicine for centuries on account of its antimicrobial properties [1,2]. Because of their large surface area-to-volume ratios, silver nanoparticles (Ag NPs) offer a large antimicrobial spectrum and greater efficacy against bacteria than common antibiotics [3-5]. Ag NPs provide new opportunities for use in both consumer and biomedical applications, making them the most commercialised NPs [6]. For example, they are integrated into garments in order to neutralize odourforming bacteria [7], they coat various food contact materials (refrigerator surfaces, storage bags…) on purpose to inhibit microorganism growth and to preserve food longer [8]. They are also used in disinfectants, deodorants, water purificants, antimicrobial sprays, etc. [9]. In the medical field, Ag NPs coat cardiovascular and neurosurgical catheters, orthopaedic and cardiovascular implants, surgical instruments, wound and burn dressings, and bone substitute biomaterials [1, 3, 10, 11]. Other biomedical applications of Ag NPs include drug delivery systems and targeting [12]. Moreover, Ag NPs have demonstrated anti-inflammatory effects, improving the outcome of the healing process [13, 14].
In some biomedical applications, Ag NPs are directly in contact with blood. Because of their reduced particle size and increased surface area Ag NPs may also enter the body and translocate into systemic blood flow after inhalation, ingestion, dermal contact or systemic administration [9, 15-17]. Ag NPs, after inhalation, oral administration or subcutaneous injection in rats, may reach the blood stream and be distributed to organs including liver, kidney and brain [15-19]. Information on the potential impact of Ag NPs on haemolysis, platelet activity and coagulation associated with human exposure is however very limited [3, 10]. An important haemolysis (destruction of red blood cells (RBC)) may result in pathological conditions such as anaemia and renal failure [20]. Moreover, a homeostatic imbalance in platelet function (primary haemostasis) or in the coagulation system (secondary haemostasis) can lead to thrombotic or haemorrhagic disorders. The plasma coagulation cascade, responsible for blood clotting, consists in a series of sequential enzymatic reactions performed by activated coagulation factors. It can be triggered through two distinct pathways: the cell-mediated tissue factor (TF) pathway and the surface-mediated contact pathway (formerly known as extrinsic and intrinsic pathways, respectively). Both pathways converge to a common pathway resulting in active thrombin generation and fibrin clot formation. The majority of these proteolytic reactions occur on anionic phospholipid membrane surfaces from activated platelets or endothelial cells in vivo and require calcium as a cofactor [21]. There is therefore a plausible possibility that some nanomaterials interfere with some of these reactions, as recently demonstrated [22]. In the present study, we focused on the effects of Ag NPs on three parameters of blood: (i) haemolysis, (ii) primary haemostasis and (iii) secondary haemostasis.
It is proposed that the no observed effect concentration (NOEC) identified for a particular NP in the most sensitive in vitro assay of the haemocompatibility testing battery could be used to guide the selection of the human free plasma concentration that could be considered safe from a haemocompatibility perspective for a first-inhuman exposure, and to identify appropriate safety margins (i.e., the ratio between the NOEC and the human free plasma concentration at the clinical starting dose). In addition, the lowest effect concentration (LOEC) for a particular NP could similarly be extrapolated to estimate the human plasma concentration where haematotoxicity would be expected to occur (toxic concentration). Both NOEC and LOEC will be determined.
2. Methods
2.1 Nanoparticle characterization
Ag NPs were obtained from the European project NanoValid. They were suspended in water at a stock concentration of 40 mg/mL, stabilized by polyvinyl pyrolidone (PVP) and stored at 4°C. Ag NPs were diluted in tyrode buffer (10 mM Hepes, 6 mM NaHCO3, 137 mM NaCl, 2.7 mM KCl, 5 mM glucose, 1 mM MgCl2 and 0.8 mM NaH2PO4, diluted in ultrapure water (milliQ 18.2 MW.cm), pH 7.4).
A proper characterization of Ag NPs was performed as previously reported [23]. Briefly, the bulk composition was determined by energy dispersive X-ray (EDX). The surface composition was analysed with an X-ray photoelectron spectroscopy (XPS) system. A droplet of 10 μL of the Ag NPs dispersion was left to dry on a gold-covered silicon wafer. The particle size distribution was measured with a DC24000 system Disc Centrifuge (CPS Instruments Inc.). A certified PVC microparticle calibration standard (226 nm), provided by the instrument supplier, was used to calibrate all measurements. The volume injected was 0.02 mL for each experiment.
2.2 Preparation of human platelet-rich plasma (PRP), platelet-poor plasma (PPP) and washed red blood cells (RBC) suspension and normal pooled plasma (NPP)
PRP, PPP, whole blood, washed RBC suspension and NPP were prepared with blood from healthy volunteers who were free from any medication for at least two weeks. Blood was collected by venepuncture into tubes containing buffered sodium citrate (109 mM, nine parts blood to one part of sodium citrate solution) (BD Vacutainer®). The study protocol was in accordance with the Declaration of Helsinki and was approved by the Medical Ethical Committee of the CHU Dinant-Godinne UCL Namur (Yvoir, Belgium).
Platelet-rich plasma (PRP) was carefully prepared by centrifugation at 200 g at room temperature for 10 min. The platelet count was adjusted to 300,000 platelets/μL and PRP were used immediately after preparation.
Platelet-poor plasma (PPP) was subsequently obtained by centrifugation at 2,000 g of the pellet at room temperature for 10 min. It was frozen at −80 °C immediately after centrifugation. It was defrosted at 37 °C just before use.
To prepare a suspension of washed RBC in PBS, whole blood is centrifuged at 3,000 g over 5 min. The PPP is removed and used for interference assays. RBC are washed with physiological phosphate buffered saline (PBS, 6.7 mM phosphate, pH=7.4) three times with intermediate centrifugation of 3,000 g over 5 min. They are then resuspended in PBS with the same volume as PBS removed.
For NPP, a total of 40 healthy individuals were included in the study. The exclusion criteria were thrombotic and/or haemorrhagic events, antiplatelet and/or anticoagulant medication, pregnancy and uptake of drugs potentially affecting the platelet and/or coagulation factor functions during the two weeks prior to the blood drawn. A written informed consent was obtained from each donor. The study population displayed the following characteristics: 24 females and 16 males aged from 19 to 48 years (mean age = 25 years) with body mass index (BMI) ranging from 16.8 to 34.6 kg/m2 (mean BMI = 22.3 kg/m2). After collection of blood, the PPP was obtained from the supernatant fraction of the blood tubes after a double centrifugation for 15 minutes at 2,000 g at room temperature. It was immediately frozen at −80°C after centrifugation. The NPP samples were thawed and kept at 37 °C just before use.
2.3 Haemolysis assays
Haemolysis assays were performed on the blood of one healthy donor: 15 μL of nanoparticles (suspended in tyrode), tyrode (negative control) or triton X-100 (positive control) are added to 285 μL of whole blood (protocol 1) or washed RBC (protocol 2). The suspension is incubated at room temperature on a shaking plate during 1 h, 4 h and 24 h. After the incubation time, the suspension is centrifuged at 10 000 g over 5 min. Supernatant is read in a 96-well plate using a microplate scanning spectrophotometer XMark (Biorad, USA) at 550 nm. The % haemolysis was calculated as: H (%) = (OD550nm sample –OD550nm tyrode)/(OD550nm Triton X-100 1% – OD550nm tyrode)*100. For each term of the equation, the corresponding interference was subtracted. The interference corresponds to the same conditions except that the solution does not contain RBC. Positive and negative controls induced 100% and 0% of lysis, respectively. The results were expressed as means ± SD (n = 3).
2.4 Platelet functional assays
2.4.1 Light transmission aggregometry (LTA)
The impact of Ag NPs on spontaneous or induced platelet aggregation was studied using the chronometric aggregometer type 490–2D as previously reported [24]. The reaction mixture for spontaneous aggregation tests contained 285 μL of PRP at 300,000 platelets/μL and 15 μL of NPs with final concentrations from 1 to 25 μg/mL. The reaction mixture for induced aggregation tests contained 255, 255 or 280 μL of PRP at 300,000 platelets/μL, with respectively 30 μL of ADP (final concentration: 20 μM, Bio/Data corporation, USA), 30 μL of collagen (final concentration: 190 μg/mL, calf skin, Bio/Data corporation, USA) or 6 μL of arachidonic acid (AA, final concentration: 600 μM, Calbiochem, Germany) and 15 μl of NPs at final concentration from 1 to 25 μg/mL. Inducers alone were also used before any experiment to check platelet reactivity. PPP was used as a reference. Data were collected with the chronolog two-channel recorders at 405 nm connected to a computer.
2.4.2 Scanning electron microscopy (FEG-SEM)
Preparation of samples was similar to LTA. The samples of PRP (500 μL) were deposited on a glass slice coated with poly-L-lysine; 500 μL of glutaraldehyde (final concentration: 2.5%) in cacodylate buffer (Na(CH3)2.AsO2.3H2O in distilled water at pH 7.4, final concentration: 0.1 M) was added over 90 minutes. Samples were then centrifuged at 2,000 g for platelet adhesion onto the slice. The glutaraldehyde solution was removed and 400 μL of 0.2 M cacodylate buffer was added. The next step is the dehydration of the sample with successive baths of alcohol from 30° to 100°. A critical point drying was performed with a specific apparatus: the Balzers Critical Point Dryer (CPD) 030 (BAL-TEC GmbH®, Germany). Afterwards, a thin layer of platinum (20 nm) was deposited under argon atmosphere on the sample with the metallizer Balzers union (BAL-TEC GmbH®, Germany). The samples were observed with FEG-SEM (Jeol, Japan; resolution of 0.6 nm at 20 keV) [22].
2.5 Coagulation: Calibrated thrombin generation test (cTGT)
The impact of Ag NPs on coagulation was studied using the calibrated thrombin generation test (cTGT) as previously reported [22]. For each experiment, a fresh mixture of fluorogenic substrate/calcium chloride buffered solution was prepared as follows: 2.6 mL of Fluo Buffer® (Thrombinoscope BV, The Netherlands) were mixed with 65 μL of Fluo substrate® (100 mM in DMSO, Thrombinoscope BV, The Netherlands). PPP-Reagent, PPP-Reagent LOW, MP-Reagent and Thrombin Calibrator (Thrombinoscope BV, The Netherlands) are four inducers, giving final assay concentrations of 5 pM tissue factor (TF) with 4 μM phospholipids (PL) and 16.7 mM CaCl2; 1 pM TF with 4 μM PL and 16.7 mM CaCl2; 4 μM PL and 16.7 mM CaCl2; and 620 nM α2-macroglobulin-thrombin complex, respectively. They are reconstituted with 1 mL distilled water according to the instructions provided by the manufacturer. A calibration curve was simultaneously performed using the thrombin calibrator. The acquired data were automatically processed by the software, which provided thrombin activity curves and lag time (minutes), Cmax (nM) and endogenous thrombin potential (ETP, nM*minutes) parameters. The NP suspensions were tested at final concentrations from 5 to 500 μg/mL. Statistical analyses were conducted with an unpaired t-test using the GraphPad Prism software (GraphPad software, v 5.01, USA).
2.6 Interferences of NPs with the detection methods used
2.6.1 NP interferences with methods using light absorbance detection
Haemolysis assay and LTA use light absorbance detection. In order to study light interference of NPs, 20 μL of Ag NP suspensions and 180 μL of suspension agent were mixed in a 96-well polystyrene plate (Greiner Bio One, Belgium). The light absorbance was measured from 400 to 800 nm using a microplate absorbance spectrophotometer XMark (Biorad, USA). For haemolysis assay, the interference was avoided by the subtraction of the OD550nm of NPs suspended in the vehicle from the measured OD550nm at the same concentration. For LTA, the NP concentration requiring an increase of 0.1 unit of the OD at 405 nm (Δ0.1 OD405nm) was calculated from the plot of the OD405nm against the NP concentration by a linear regression curve using the GraphPad Prism® software (GraphPad Prism software, v 5.01, USA). The lower this parameter, the more NP suspensions absorb light.
2.6.2 NP interferences with the cTGT method
The autofluorescence of the NP suspensions was measured at 390/460 nm using the microplate fluorometer Fluoroskan Ascent® FL (Thermo Labsystems, The Netherlands). Furthermore, the quenching of 7-amino-4-methyl coumarin acetic acid (AMC) by the NP suspensions was also measured.
3. Results
3.1 Nanoparticle characterization
Ag NPS have a spheroid shape.
A bimodal distribution was observed with primary particles around 16 nm and agglomerates around 71 nm (Table 1). The NP surface composition was not similar to their bulk composition with a lower content of oxygen and the presence of nitrogen. The elements other than Ag are attributed to traces of the suspension solution.
Table 1.
Summary of Ag NPs characterization
| Parameters | Measurement |
|---|---|
| Hydrodynamic diameter (CLS, [nm]) | 16 (primary particles), 71 (agglomerates) |
| Elemental composition | Ag O C N Na |
| Surface composition (XPS, [% at])* | 5 23.8 61 9.2 1 |
| Bulk composition (SEM-EDX, [% at])* | 4.71 34.22 60.78–0.29 |
Ag NPs are dispersed in water and stabilized with PVP
3.2 Haemolysis
We performed the absorbance spectrum of the supernatant of RBC suspension 0.5% (v/v) incubated with Triton X-100 1% (v/v) (data not shown). We selected the wavelength of 550 nm to perform our assay. Note that OD interference has been observed with Ag NPs due to their absorbance at 550 nm. This interference was avoided by the subtraction of the OD550 nm of NPs suspended in the vehicle from the measured OD550 nm at the same concentration. Negative control (tyrode) and positive control (triton X-100 1%) induced 0% and 100% respectively of haemolysis.
Ag NPs at 1 μg/mL, 10 μg/mL and 100 μg/mL induced no haemolysis in whole blood (data not shown) after 1 h, 4 h or 24 h (data not shown). With washed RBC, no haemolysis was observed, except for the concentration of 100 μg/mL after 24 h of incubation. A statistically different percentage of haemolysis (4.7%) is obtained (Figure 1).
Figure 1.

Human RBC lysis (%) induced by Ag NPs in washed RBC after 1 h, 4 h and 24 h at concentrations ranging from 1 to 100 μg/mL (protocol 2). Triton X-100 1% and tyrode (v/v) are respectively used as positive control and negative control. Mean (%) ± SD, n = 3. Statistical analysis was performed with GraphPad Prism software (unpaired t-test). Statistical significance between control and Ag NPs samples: * indicates p<0.05.
3.3 Platelet function
To evaluate the suitability of LTA for Ag NPs, the light absorbance properties of these NPs was determined. Ag NP suspensions absorb light between 400 and 800 nm.
According to the detection sensitivity of LTA, the NP concentration required to obtain a 0.1 unit increase in the OD at 620 nm (Δ0.1 OD620 nm) was measured; significant light absorbance was observed from a concentration higher than 10 μg/mL Ag NPs.
The potential impact of Ag NPs on platelet activity was investigated at the concentration without interference in tested conditions (< 25 μg/mL). The cut-off was arbitrarily defined at 5% reduction of the aggregation by agonist in control conditions. At the investigated concentrations avoiding interferences, Ag NPs did not significantly affect platelet aggregation, regardless of the inducer used (ADP, collagen or AA) (Figure 2). In the absence of agonists, Ag NPs did not induce spontaneous platelet aggregation (data not shown).
Figure 2.

Platelet aggregation induced by ADP (A), collagen (B) or AA (C) at different concentrations of Ag NPs. PBS is used as a negative control. Results are expressed as % of response (Mean ± SD, n = 6, unpaired t-test).
In FEG-SEM, a reduction of platelet adhesion is observed with Ag NPs at 50 μg/mL (Figure 3D and E). FEG-SEM does not allow conclusion of a potential effect of Ag NPs on the platelet activation and aggregation (Figure 3).
Figure 3.

SEM pictures of platelet adhesion without (A -C) or with Ag NPs at a final concentration of 50 μg/mL (D -F). Platelet aggregation was induced by AA (C, F). Scale bare = 10 μm (A, D) or 1 μm (B, C, E, F). Arrows indicate adherent platelets.
3.4 Coagulation: Calibrated thrombin generation test (cTGT)
The investigations of the two potential interferences of Ag NPs with cTGT indicated that Ag NPs were not autofluorescent at wavelengths of 390/460 nm, but they were able to reduce the fluorescent signal of the AMC fluorophore. This interference can be excluded by performing a specific calibration curve for each concentration tested [22].
Figure 4 shows representative active thrombin profiles after activation by the use of three specific inducers in the presence of Ag NPs. Figure 5 represents the control parameters. Firstly, the investigation of the TF pathway showed that only a high concentration of Ag NPs (500 μg/mL) increases the concentration of generated thrombin (Cmax) (Figure 4A and Figure 5B). Secondly, the active thrombin was generated through the TF pathway, but with a lower concentration of TF in order to allow the thrombin-positive feedback loop activation on the contact pathway (Figure 4B). In these specific activation conditions, it appeared that high concentration decreased lag time and increased Cmax (Figure 5A and B).
Figure 4.

Representative thrombin activity profiles induced by TF (A), contact (C) or both pathways (B) in the presence of Ag NPs. Data shown are the means of three independent experiments.
Figure 5.

Control parameters (lag time (A), Cmax (B) and ETP (C)) of thrombin activity profiles induced by TF, contact or both pathways of negative control and different concentrations of Ag NPs. Statistical analysis was performed with GraphPad Prism software (unpaired t-test). Statistical significance between control and Ag NPs samples: * indicates p<0.05; ** indicates p<0.01; *** indicates p<0.001.
When the contact pathway was triggered, Ag NPs showed a procoagulant activity with a decrease of lag time and an increase of Cmax (Figure 4C). Based on these results, it appears that Ag NPs have a procoagulant activity by reducing lag time and by increasing Cmax when the contact pathway (4 μM PL) is preferentially stimulated.
3.5 No/low observed effect concentration
NOEC and LOEC were determined for blood parameters studied. For red blood cells, the NOEC and LOEC were 50 μg/mL and 100 μg/mL, respectively. The NOEC and LOEC were 5 μg/mL and 50 μg/mL for coagulation, respectively. For platelet function, due to the technical limitations of LTA, the NOEC is 25 μg/mL and no LOEC could be determined. The effects on platelet adhesion observed in FEG-SEM are a qualitative result allowing no NOEC and no LOEC.
4. Discussion
The increasing use of Ag NPs leads to the need of toxicological evaluation to insure patient safety [25]. There is limited information on the biological effects of Ag NPs on human blood cells and the potential risk of inducing thrombosis [11]. Moreover, some published studies do not provide information on interferences of the assays. In addition, results are sometimes contradictory [26-29]. Physicochemical properties of NPs are of major importance in toxicology and may be affected by the dispersing media [30, 31]. Therefore, results of blood assays can differ according to the media used. We suggested that the NP suspensions should be prepared in the most physiological media suitable for blood components (tyrode buffer), avoiding sonication [22, 25]. As their unique size and composition affect their functionality, complete physicochemical description of nanoparticles was performed, allowing the comparison of results between scientific studies [25].
The determination of haemolysis is based on haemoglobin absorbance at 550 nm, with subtraction of the interference of Ag NPs. A significant difference was observed in washed RBC with Ag NPs at 50 and 100 μg/mL after 24 h of incubation in comparison with controls. A lower haemolytic effect was observed in whole blood than in washed RBC. This is probably due to the fact that, in whole blood, an adsorption of plasma proteins on the NPs may occur and impact upon the haemolytic properties. This effect has already been reported in the literature for SiO2 NPs [32, 33]. Although various studies evaluated the haemolysis induced by Ag NPs [25, 34, 35], it remains difficult to compare results across studies due to the lack of harmonization of standardized physicochemical characterizations and in vitro haemolysis protocols. However, our results are in agreement with previous studies that concluded to the prohaemolytic properties of Ag NPs [25, 34, 35]. These results may have a clinical impact, since a release of haemoglobin can lead to adverse health effects such as anaemia, pulmonary hypertension, renal toxicity [36]. The mechanism explaining this induced haemolysis by Ag NPs has not yet been completely elucidated. It is known that low concentrations of Ag ions lead to RBC death [37, 38]. In contact with blood, metallic silver ionizes and releases ions in the bloodstream, which can interact with transmembrane proteins [2, 25]. However silver ion generation is not the only factor for haemolysis; other mechanisms contribute to haemolysis induced by NPs (deformability, adhesiveness, membrane vesiculation etc.) [25, 39].
Two techniques were used to assess the potential effect of Ag NPs on platelet function: LTA and FEG-SEM. With the first technique, Ag NPs did not affect the platelet aggregation at the highest tested concentration avoiding interferences (25 μg/mL). Jun et al. also showed interference of Ag NPs with light transmission, especially at high concentrations. With the second technique, an increase of the platelet adhesion is observed at 50 μg/mL, with no observed effect on the two following steps of the primary haemostasis (i.e., platelet activation and aggregation). Jun et al. and Krajewski et al. demonstrated that Ag NPs induce platelet activation and aggregation [26, 27]. An anti-aggregating effect of Ag NPs has been demonstrated by Shrivastava et al. using LTA [40]. However, the interference of Ag NPs was not taken into account with this technique. Moreover, as discussed by Deb et al., the anti-platelet effect observed by Shrivastava et al. was due to citric acid present at the surface of the NPs [41]. The key mechanism underlying platelet activation induced by Ag NPs would be an increase of intracellular calcium levels, directly related to GPIIb/IIIa activation and leading to P-selectin expression and serotonin secretion [26].
On coagulation, the sensitive cTGT assay showed that Ag NPs had significant procoagulant activity. These results were in accordance with the work of Jun et al. which demonstrated the procoagulant activity of silver NPs <100 nm on two different assays (chromogenic generation assay and P-selectin expression) [26]. In the cTGT assays, the interferences (autofluorescence of the NP suspensions and the quenching of the fluorophore signal) are excluded by performing, for each NP concentration, a specific calibration curve run [22]. To explain the procoagulant effect observed, Jun et al. suggested that Ag NPs enhance procoagulant activity through phosphatidylserine exposure in platelets [26]. On the other side, Shrivastava et al. concluded to a delay of fibrin polymerization by silver NPs (10–15 nm). Interestingly, this effect is strongly inhibited when the experiment is performed with bovine serum albumin at a concentration below the protein concentration in the blood [28]. Martínez-Gutierrez et al. concluded to a moderate anticoagulant effect of Ag NPs on the intrinsic pathway performing an activated partial thromboplastin time (aPTT). We performed the same assay using a mechanical semi-automated coagulometer KC10 (Amelung, Germany) with Synthasil® (Instrumentation Laboratory, Lexington, KY, USA) and CK Prest® (Diagnostica Stago, Asnières, France). We observed a significant and dose-dependant decrease in coagulation with aPTT with Ag NPs (data not shown). Contrarily, we demonstrated a procoagulant effect of Ag NPs with cTGT mainly on the contact pathway. The conclusion of a procoagulant activity performed by cTGT should be regarded as more physiologically relevant and predictive. Indeed, reagents used in KC 10 contain, in addition to phospholipid substitutes, colloidal silica activator for Synthasil® and kaolin for CK Prest® to induce the contact pathway. cTGT reagents contain physiological phospholipids. In KC10, an interaction of charges between the negatively charged reagents and the Ag NPs delivering positive ions is anticipated. Consequently, this non-physiological interaction prevents tenase and prothrombinase complex formation, finally inducing an increase in the coagulation time. Moreover, procoagulant activity mediated by platelets could amplify the procoagulant effect observed on the coagulation cascade by Ag NPs. Because of the abovementioned interactions, aPTT using colloidal silica activator or kaolin to induce the contact pathway should not be considered as a relevant assay for assessing the impact of charged nanomaterials on coagulation. As suggested in previous work, cTGT appears to be the goldstandard assay [22].
Regarding biomedical applications, Ag NPs are currently used for wound dressing because of their antimicrobial effect [42]. Moreover, recent studies have shown that Ag NPs have significant anti-inflammatory effects [13, 43], preventing the wound from inflammation. In this study, we demonstrated a platelet proadhesion and a procoagulant effect promoting the healing process [44].
In the emerging field of nanomedicine, blood could be in contact with Ag NPs after injection or direct contact (coated biomaterial). We demonstrated prohaemolytic, proadherent and procoagulant effects of Ag NPs that could enhance the risk of thrombosis.
The most sensitive in vitro assay of the haemocompatibility testing battery for Ag NPs is the cTGT, used to propose a NOEC at 5 μg/mL and a LOEC at 50 μg/mL. The NOEC could be used to determine a safe human plasma-free concentration for a first-inhuman exposure and to identify appropriate safety margins. In addition, the LOEC could estimate the human plasma concentration where haematotoxicity would be expected to occur. As the human maximum therapeutic free plasma concentration would approach the toxic concentration, the probability of toxicity would increase and the exposure margin would decrease. The latter could also guide specific safety monitoring that would need to be foreseen in a clinical setting. As such, these in vitro hemocompatiblity data could contribute to the identification of starting and maximum doses as described in the ICH M3(R2) guideline on non-clinical safety studies for the conduct of human clinical trials and marketing authorization for pharmaceuticals [45]. It should be noted that the use of in vitro (haemato-) toxicity data in a decision-making process could be considered provided that the basic criteria of test method qualification are met [46].
5. Conclusion
Silver NPs present numerous interactions with blood components as RBCs, platelets and a coagulation system. We recommend specific haematological tests overcoming interferences to determine NP haemocompatibility and estimate NOEC. Using such tests, Ag NPs demonstrated prohaemolytic, procoagulant effects, and promote platelet adhesion. A maximal NOEC and LOEC in blood have been determined at 5 and 50 μg/mL, respectively. For local Ag NPs applications such as wound dressings, these properties may be favourable. For the development of Ag nanomedicines from a haemocompatibility perspective, the NOEC and LOEC may be useful for first-in-human exposure and for identifying appropriate safety margins.
6. Funding
The research leading to these results has received funding from the European Community's Seventh Framework Programme (FP7/2007-2013) under grant agreement n° 263147 (NanoValid – Development of reference methods for hazard identification, risk assessment and LCA of engineered nanomaterials).
7. Conflit of interest
The authors declare there is no conflict of interest.
References
- [1].Chaloupka K, Malam Y, Seifalian AM. (2010) Nanosilver as a new generation of nanoproduct in biomedical applications. Trends Biotechnol. 28:580–8. [DOI] [PubMed] [Google Scholar]
- [2].Lansdown AB. (2010) A pharmacological and toxicological profile of silver as an antimicrobial agent in medical devices. Adv Pharmacol Sci. 2010:910686. [DOI] [PMC free article] [PubMed] [Google Scholar]
- [3].Ahamed M, Alsalhi MS, Siddiqui MK. (2010) Silver nanoparticle applications and human health. Clin Chim Acta. 411:1841–8. [DOI] [PubMed] [Google Scholar]
- [4].Mohanty S, Mishra S, Jena P, Jacob B, Sarkar B, Sonawane A. (2012) An investigation on the antibacterial, cytotoxic, and antibiofilm efficacy of starch-stabilized silver nanoparticles. Nanomedicine. 8:916–24. [DOI] [PubMed] [Google Scholar]
- [5].Shahverdi AR, Fakhimi A, Shahverdi HR, Minaian S. (2007) Synthesis and effect of silver nanoparticles on the antibacterial activity of different antibiotics against Staphylococcus aureus and Escherichia coli. Nanomedicine. 3:168–71. [DOI] [PubMed] [Google Scholar]
- [6].Scholars WWICf. A nanotechnology consumer products inventory.
- [7].Benn TM, Westerhoff P. (2008) Nanoparticle silver released into water from commercially available sock fabrics. Environ Sci Technol. 42:4133–9. [DOI] [PubMed] [Google Scholar]
- [8].Chaudhry Q, Scotter M, Blackburn J, Ross B, Boxall A, Castle L, et al. (2008) Applications and implications of nanotechnologies for the food sector. Food Addit Contam Part A Chem Anal Control Expo Risk Assess. 25:241–58. [DOI] [PubMed] [Google Scholar]
- [9].Chen X, Schluesener HJ. (2008) Nanosilver: A nanoproduct in medical application. Toxicol Lett. 176:1–12. [DOI] [PubMed] [Google Scholar]
- [10].You J, Zhang Y, Hu Z. (2011) Bacteria and bacteriophage inactivation by silver and zinc oxide nanoparticles. Colloids Surf B Biointerfaces. 85:161–7. [DOI] [PubMed] [Google Scholar]
- [11].Greulich C, Diendorf J, Gessmann J, Simon T, Habijan T, Eggeler G, et al. (2011) Cell type-specific responses of peripheral blood mononuclear cells to silver nanoparticles. Acta Biomater. 7:3505–14. [DOI] [PubMed] [Google Scholar]
- [12].Dreaden EC, El-Sayed MA. (2012) Detecting and destroying cancer cells in more than one way with noble metals and different confinement properties on the nanoscale. Acc Chem Res. 45:1854–65. [DOI] [PMC free article] [PubMed] [Google Scholar]
- [13].Nadworny PL, Wang J, Tredget EE, Burrell RE. (2008) Anti-inflammatory activity of nanocrystalline silver in a porcine contact dermatitis model. Nanomedicine. 4:241–51. [DOI] [PubMed] [Google Scholar]
- [14].Kwan KH, Yeung KW, Liu X, Wong KK, Shum HC, Lam YW, et al. (2013) Silver nanoparticles alter proteoglycan expression in the promotion of tendon repair. Nanomedicine. DOI: 10.1016/j.nano.2013.11.015. [DOI] [PubMed]
- [15].Sung JH, Ji JH, Yoon JU, Kim DS, Song MY, Jeong J, et al. (2008) Lung function changes in Sprague-Dawley rats after prolonged inhalation exposure to silver nanoparticles. Inhal Toxicol. 20:567–74. [DOI] [PubMed] [Google Scholar]
- [16].Oberdorster G, Oberdorster E, Oberdorster J. (2005) Nanotoxicology: An emerging discipline evolving from studies of ultrafine particles. Environ Health Perspect. 113:823–39. [DOI] [PMC free article] [PubMed] [Google Scholar]
- [17].Sung JH, Ji JH, Park JD, Yoon JU, Kim DS, Jeon KS, et al. (2009) Subchronic inhalation toxicity of silver nanoparticles. Toxicol Sci. 108:452–61. [DOI] [PubMed] [Google Scholar]
- [18].Takenaka S, Karg E, Roth C, Schulz H, Ziesenis A, Heinzmann U, et al. (2001) Pulmonary and systemic distribution of inhaled ultrafine silver particles in rats. Environ Health Perspect. 109 Suppl 4:547–51. [DOI] [PMC free article] [PubMed] [Google Scholar]
- [19].Kim YS, Song MY, Park JD, Song KS, Ryu HR, Chung YH, et al. (2010) Subchronic oral toxicity of silver nanoparticles. Part Fibre Toxicol. 7:20. [DOI] [PMC free article] [PubMed] [Google Scholar]
- [20].Dobrovolskaia MA, Clogston JD, Neun BW, Hall JB, Patri AK, McNeil SE. (2008) Method for analysis of nanoparticle hemolytic properties in vitro. Nano Lett. 8:2180–7. [DOI] [PMC free article] [PubMed] [Google Scholar]
- [21].Smith SA. (2009) The cell-based model of coagulation. J Vet Emerg Crit Care (San Antonio). 19:3–10. [DOI] [PubMed] [Google Scholar]
- [22].Laloy J, Robert S, Marbehant C, Mullier F, Mejia J, Piret JP, et al. (2012) Validation of the calibrated thrombin generation test (cTGT) as the reference assay to evaluate the procoagulant activity of nanomaterials. Nanotoxicology. 6:213–32. [DOI] [PubMed] [Google Scholar]
- [23].Mejia J, Tichelaar F, Saout C, Toussaint O, Masereel B, Mekhalif Z, et al. (2011) Effects of the dispersion methods in Pluronic F108 on the size and the surface composition of MWCNTs and their implications in toxicology assessment. Journal of Nanopart Res. 13:655–67. [Google Scholar]
- [24].Laloy J, Mullier F, Alpan L, Mejia J, Lucas S, Chatelain B, et al. (2014) A comparison of six major platelet functional tests to assess the impact of carbon nanomaterials on platelet function: A practical guide. Nanotoxicology. 8:220–32. [DOI] [PubMed] [Google Scholar]
- [25].Choi J, Reipa V, Hitchins VM, Goering PL, Malinauskas RA. (2011) Physicochemical characterization and in vitro hemolysis evaluation of silver nanoparticles. Toxicol Sci. 123:133–43. [DOI] [PubMed] [Google Scholar]
- [26].Jun EA, Lim KM, Kim K, Bae ON, Noh JY, Chung KH, et al. (2011) Silver nanoparticles enhance thrombus formation through increased platelet aggregation and procoagulant activity. Nanotoxicology. 5:157–67. [DOI] [PubMed] [Google Scholar]
- [27].Krajewski S, Prucek R, Panacek A, Avci-Adali M, Nolte A, Straub A, et al. (2013) Hemocompatibility evaluation of different silver nanoparticle concentrations employing a modified Chandler-loop in vitro assay on human blood. Acta Biomater. 9:7460–8. [DOI] [PubMed] [Google Scholar]
- [28].Shrivastava S, Singh SK, Mukhopadhyay A, Sinha AS, Mandal RK, Dash D. (2011) Negative regulation of fibrin polymerization and clot formation by nanoparticles of silver. Colloids Surf B Biointerfaces. 82:241–6. [DOI] [PubMed] [Google Scholar]
- [29].Shrivastava Siddhartha TB, Singh Sunil K., Singh Gajendra, Ramachandrarao, Dash Debabrata. (2009) Characterization of antiplatelet properties of silver nanoparticles. ACS Nano. 3:1357–64. [DOI] [PubMed] [Google Scholar]
- [30].Bouwmeester H, Lynch I, Marvin HJ, Dawson KA, Berges M, Braguer D, et al. (2011) Minimal analytical characterization of engineered nanomaterials needed for hazard assessment in biological matrices. Nanotoxicology. 5:1–11. [DOI] [PubMed] [Google Scholar]
- [31].Taurozzi JS, Hackley VA, Wiesner MR. (2011) Ultrasonic dispersion of nanoparticles for environmental, health and safety assessment–issues and recommendations. Nanotoxicology. 5:711–29. [DOI] [PubMed] [Google Scholar]
- [32].Shi J, Hedberg Y, Lundin M, Wallinder Odnevall I, Karlsson HL, Moller L. (2012) Hemolytic properties of synthetic nano- and porous silica particles: The effect of surface properties and the protection by the plasma corona. Acta Biomater. 8:3478–90. [DOI] [PubMed] [Google Scholar]
- [33].Lundqvist M, Stigler J, Cedervall T, Berggard T, Flanagan MB, Lynch I, et al. (2011) The evolution of the protein corona around nanoparticles: A test study. ACS Nano. 5:7503–9. [DOI] [PubMed] [Google Scholar]
- [34].Kwon T, Woo HJ, Kim YH, Lee HJ, Park KH, Park S, et al. (2012) Optimizing hemocompatibility of surfactant-coated silver nanoparticles in human erythrocytes. J Nanosci Nanotechnol. 12:6168–75. [DOI] [PubMed] [Google Scholar]
- [35].de Mel A, Chaloupka K, Malam Y, Darbyshire A, Cousins B, Seifalian AM. (2012) A silver nanocomposite biomaterial for blood-contacting implants. J Biomed Mater Res A. 100:2348–57. [DOI] [PubMed] [Google Scholar]
- [36].Rother RP, Bell L, Hillmen P, Gladwin MT. (2005) The clinical sequelae of intravascular hemolysis and extracellular plasma hemoglobin: A novel mechanism of human disease. JAMA. 293:1653–62. [DOI] [PubMed] [Google Scholar]
- [37].Ballinger PM, Brown BS, Griffin MM, Steven FS. (1982) Evidence for carriage of silver by sulphadimidine: Haemolysis of human erythrocytes. Br J Pharmacol. 77:141–5. [DOI] [PMC free article] [PubMed] [Google Scholar]
- [38].Sopjani M, Foller M, Haendeler J, Gotz F, Lang F. (2009) Silver ion-induced suicidal erythrocyte death. J Appl Toxicol. 29:531–6. [DOI] [PubMed] [Google Scholar]
- [39].Nohl H, Stolze K. (1998) The effects of xenobiotics on erythrocytes. Gen Pharmacol. 31:343–7. [DOI] [PubMed] [Google Scholar]
- [40].Shrivastava S, Bera T, Singh SK, Singh G, Ramachandrarao P, Dash D. (2009) Characterization of antiplatelet properties of silver nanoparticles. ACS Nano. 3:1357–64. [DOI] [PubMed] [Google Scholar]
- [41].Deb S, Raja SO, Dasgupta AK, Sarkar R, Chattopadhyay AP, Chaudhuri U, et al. (2012) Surface tunability of nanoparticles in modulating platelet functions. Blood Cells Mol Dis. 48:36–44. [DOI] [PubMed] [Google Scholar]
- [42].Tian J, Wong KK, Ho CM, Lok CN, Yu WY, Che CM, et al. (2007) Topical delivery of silver nanoparticles promotes wound healing. ChemMedChem. 2:129–36. [DOI] [PubMed] [Google Scholar]
- [43].Martinez-Gutierrez F, Thi EP, Silverman JM, de Oliveira CC, Svensson SL, Vanden Hoek A, et al. (2012) Antibacterial activity, inflammatory response, coagulation and cytotoxicity effects of silver nanoparticles. Nanomedicine. 8:328–36. [DOI] [PubMed] [Google Scholar]
- [44].Reinke JM, Sorg H. (2012) Wound repair and regeneration. Eur Surg Res. 49:35–43. [DOI] [PubMed] [Google Scholar]
- [45].European Medicine Agency (EMA). (2008) ICH Topic M 3 (R2) Non-clinical safety studies for the conduct of human clinical trials and marketing authorization for pharmaceuticals. CPMP/ICH/286/95. 1–22.
- [46].European Medicine Agency (EMA). (2014) Qualification of novel methodologies for drug development: Guidance to applicants. EMA/CHMP/SAWP/72894. 1–16.