Abstract
The interactions between and with nanostructures can only be fully understood when the functional group distribution on their surfaces can be quantified accurately. Here we apply a combination of direct stochastic optical reconstruction microscopy (dSTORM) imaging and probabilistic modelling to analyse molecular distributions on spherical nanoparticles. The properties of individual fluorophores are assessed and incorporated into a model for the dSTORM imaging process. Using this tailored model, overcounting artefacts are greatly reduced and the locations of dye labels can be accurately estimated, revealing their spatial distribution. We show that standard chemical protocols for dye attachment lead to inhomogeneous functionalization in the case of ubiquitous polystyrene nanoparticles. Moreover, we demonstrate that stochastic fluctuations result in large variability of the local group density between particles. These results cast doubt on the uniform surface coverage commonly assumed in the creation of amorphous functional nanoparticles and expose a striking difference between the average population and individual nanoparticle coverage.
Determining the spatial arrangement of molecules on a nanoparticle’s surface is key to understanding its interactions. Here, the authors use dSTORM imaging and probabilistic modelling to map the distribution of fluorophores on a nanoparticle, finding that ligand coverage is heterogeneous and highly variable between individual particles.
Introduction
Control over multivalent interactions is essential in engineering various interactions between and with nanoparticles1–5. Multivalency—i.e. the simultaneous occurrence of multiple molecular recognition events between two entities—presents a ubiquitous principle for tuning a variety of interactions, due to the profound thermodynamic and kinetic consequences associated with interdependence of binding events6–10. The prevalence of multifunctional structures in living cells has prompted efforts to improve the understanding of multivalency in biological interactions8,11, and synthetic multifunctional scaffolds have attracted increasing attention as therapeutic agents12,13.
Multivalent interactions are highly sensitive to the local density and spatial arrangement of ligands11,12,14,15. As such, inadequate characterization of multifunctional structures is a major hurdle for the implementation of multivalency-based approaches in nanotechnology. The average functionalization density can easily be obtained using fluorescence assays or other ensemble methods, but these analyses provide no spatial information16. Additionally, the influence of stochastic variations in ligand concentrations, which has far-reaching consequences in biochemical signalling17,18, cannot be probed due to the averaging of signals inherent in these approaches. Hence, the average functionalization degree is not indicative for the surfaces of individual nanostructures in a population, and does not provide a reliable predictor for their properties.
Microscopic methods seem most suitable for providing a detailed representation of functional group topology on the single-scaffold level. For instance, the binding events in cellular interactions are separated on the nanoscale, and only few techniques can provide the spatial resolution required. Scanning probe microscopies (i.e. atomic force microscopy and scanning tunneling microscopy) provide very high resolution and have been applied in the study of nanoscale structures19,20. Progress has also been reported by using electron microscopy, in studies of epitope distributions in protein complexes21 and nanoparticles22. However, these approaches are generally invasive and lack chemical specificity, especially when multiple labels are required.
Super-resolution optical microscopy combines benign sample preparation with high sensitivity and specificity23–26, and as such provides perfect complementarity with the aforementioned microscopic techniques. Localization-based implementations provide high versatility and nanometre spatial resolution, and thereby present a unique capability to distinguish complex chemical features in a crowded molecular environment. Super-resolution images of biological and synthetic nanostructures have already facilitated several ground-breaking studies27–32, but provide intriguing challenges in terms of quantification33–35. For example, the finite localization precision combined with the reversible blinking of fluorescent dyes result in overcounting errors that have been approached using specific experimental methods (e.g. quantitative points accumulation in nanoscale topography (qPAINT)36,37) or using computational tools38. For photoactivatable dyes with short-lived dark states, time-correlation of individual localizations has been applied to diminish overcounting artefacts39,40. More generally, correlative approaches also reduce overcounting and provide an accurate indication of dye density, at the cost of local averaging of localizations41,42. As an alternative, probabilistic approaches can be used to address the challenge of fluorophore counting43, and several recent papers discuss the application of these methods in the context of direct stochastic optical reconstruction microscopy (dSTORM) and photo-activated localization microscopy imaging44–47.
The focus of existing literature is on quantifying dye (copy) numbers in well-separated clusters, thereby decoupling quantification and spatial analysis. Nevertheless, accurate estimation of both numerical and geometric factors is required to study realistic nanostructures with a range of interfluorophore distances, prompting a more thorough evaluation of spatial distributions based on the precision of individual localizations. A recently developed Bayesian clustering method has demonstrated the robust identification of localization clusters in a range of sample conditions, in both 2D and 3D48,49. However, this work focuses on separating molecule clusters from background noise, rather than on the structure of the molecular clusters, and the occurrence of multiple blinking in dSTORM hinders the application of these methods for quantitative dye location estimation.
In this work, we quantitatively analyse the functional group distribution on the surface of a multifunctional synthetic nanoparticle, using a combination of tailored photophysical modelling of the dye behaviour and Maximum Likelihood Estimation (MLE) of localization patterns in dSTORM. We assess the number of dyes in line with existing probabilistic approaches43, subsequently apply this information to estimate the dye locations based on the spatial modelling, and validate this approach using simulated datasets. The methodology is compatible with long-lived dark states common in dSTORM and PAINT microscopies, and fully exploits the high photon budget and repeated blinking inherent to these techniques. For prevalent amorphous polystyrene nanoparticles, we demonstrate large stochastic fluctuation in the quantities of functional groups attached to different particles in a population. Moreover, we establish spatial inhomogeneity of the attached moieties on individual nanostructures, representing an even larger variation in local dye density than can be explained by “random” attachment. Finally, we provide an empirical measure to quantify dye clustering on nanoparticles, allowing the customized prediction of interaction efficiency in a heterogeneous population.
Results
Addressing stochastic effects
The number of functional groups on a nanostructure cannot be observed directly from localization-based super-resolution images due to overcounting artefacts. Figure 1a schematically illustrates the dSTORM imaging procedure. First, reactive handles on the surface of a nanostructure are functionalized with photoswitchable dyes. During dSTORM acquisition, these dyes switch between short-lived fluorescent and long-lived dark states, and the emitted photons are captured by the camera. The centroids of the resulting diffraction-limited spots are fitted to obtain localizations, and a large collection of such localizations forms the dSTORM image. This fitting procedure has a finite resolution limited mostly by the brightness of the observed spot, resulting in an error in the calculated location of the centroid (I in Fig. 1a). Additionally, photoswitching of the fluorescent dyes occurs repeatedly and thus a single dye may yield multiple localizations over the course of an acquisition period (II in Fig. 1a). Hence, it is increasingly difficult to assign localizations to particular dyes in case multiple fluorophores are emitting in close proximity (III in Fig. 1a). The random nature of these photophysical processes represents an important obstacle in the determination of ligand densities.
In order to accurately analyse dye locations on densely functionalized nanoparticles, our analysis will rely on three properties: (i) the dye photophysics, including overcounting, need to be quantitatively described; (ii) the variability in the number of dyes attached to individual nanoparticles needs to be accurately captured; (iii) the spatial estimation algorithm must reliably reproduce the underlying (random, 3D and relatively dense) dye distribution from localization collections using (i) and (ii).
If properties (i), (ii), and (iii) are verified, and the dye dynamics are assumed not to change in the presence of other dyes, then the experimental distribution of dye labels on nanoparticles can be determined from dSTORM images. In this experiment, we apply an MLE procedure (vide infra) incorporating blinking behaviour and the uncertainties associated with individual localizations. Property (i) is validated by comparing the model fit with data from beads with a single-dye label attached (see section Photophysical modelling). Given (i), property (ii) is validated using data on the number of localizations on experimental beads (see section Nanoparticle functionalization). Lastly, property (iii) is validated using simulations, as illustrated in Fig. 1b (see section Spatial distribution of functional groups). In these simulations, fluorescent emitters are distributed over the surface of a sphere, the dSTORM imaging and localization process is mimicked, and the MLE procedure is applied to the resulting localizations. Since the underlying distribution of the emitters is known, the performance of the estimation procedure can be assessed, thus benchmarking our method.
Photophysical modelling
The single-molecule dynamics of the Alexa647 fluorophore on a nanoparticle surface have been characterized to quantify the relevant photophysical processes. Carboxyl-functional polystyrene nanoparticles (diameter 330 nm) functionalized with a single Alexa647 moiety (Fig. 2a, experimental details are described in the Methods section) have been immobilized to a glass coverslip, and imaged using astigmatism-based 3D-dSTORM (Fig. 2b). The resulting localization clusters correspond to a single fluorophore photoswitching over the course of a dSTORM acquisition, providing a suitable dataset to verify property (i).
Inspired by existing models for photoactivatable dyes39, we apply a three-state model for photoswitchable dyes (Fig. 2c). Such a competition between processes with constant transition probabilities results in a geometric distribution for the number of active periods (i.e. a complete period between thiol-mediated or irreversible dark states) before bleaching, experimentally equating the number of localizations per dye. Indeed, the observed localizations can be adequately fit using a geometric distribution, as shown in Fig. 2c.
Since the number of photons in a localization determines the accuracy of its centroid fit50,51, this is a crucial parameter to quantify the spatial aspects of fluorophore distribution. Previous single-molecule studies have shown that fluorophores do not emit constantly over an active period, but alternate short-lived emissive and non-emissive states within this period52–54. Assuming exponential residence times in the emissive state, the total number of photons emitted is well approximated by a gamma distribution, which can indeed adequately fit the data (Fig. 2d).
Individual localizations are modelled as a 3D Gaussian distribution around the real location of the dye, with variances depending on the number of photons. Hence, the 3D spread of localizations that originate from a single fluorophore is used as an experimental measure of localization uncertainty (Fig. 2e). Figure 2f shows an overlay of the experimental localization uncertainty (solid points) with different variance expressions. We extended the theoretical expressions derived by Mortenson et al.55 for the estimation errors of a 2D Gaussian mask estimator for the centroid location to astigmatic 3D-imaging (red surface). The considerable deviation to the experimental data indicates that this basic framework fails to capture all relevant processes. If the expression is extended to include the effects of drift correction, a better approximation is obtained (blue surface). Further enhanced prediction of experimental data is provided by incorporating variability related to optical effects—for example, coupling of the fluorophore excitation dipole to nearby interfaces56. The resulting localization-dependent distortion of the PSF may be captured by replacing the Gaussian distribution by a normal-normal mixture model, and the complete model provides a further improved estimate of localization errors in three dimensions (green surface).
Nanoparticle functionalization
For the purpose of analysing the distribution of functional groups on the surface of a nanoparticle, and in particular the influence of stochastic variability, multifunctional dye-appended 330 nm polystyrene beads have been created (Fig. 3a). Functionalization has been performed using amine-NHS chemistry in dilute solution (nanoparticle and experimental details can be found in the Methods section), a common procedure for creating therapeutically active nanoparticles. By adjusting the reaction conditions, nanoparticles with different average degrees of functionalization (low, medium, high) could be generated in a simple manner. Medium-density particles have been imaged using astigmatic 3D-dSTORM (vide supra), resulting in well-reconstructed spherical clusters of localizations (Fig. 3b).
A measure of the variability between nanoparticles in a population can be obtained by investigating the distribution of the number of localizations per bead. In Fig. 3c, the probability mass function for this number of localizations is depicted (grey bars). This distribution is determined by the interplay between two properties: the number of fluorophore molecules attached to a nanoparticle, and the number of localizations per fluorophore. The latter is geometrically distributed with known parametrization (Fig. 2c). For fully random attachment processes, in which fluorophore molecules in the reacting solution have an equal probability to attach to any nanoparticle, the former property is expected to follow a Poisson distribution. Combining these distributions results in a compound Poisson distribution, which has been fit to the probability mass function in Fig. 3c (red solid line). As can be clearly seen, a compound Poisson distribution does not provide an appropriate fit. However, when the functionalization process is not Poissonian, but is characterized by additional dispersion instead, the number of dyes per nanoparticle can be captured by a negative binomial distribution. Then, the observed number of localizations per nanoparticle equals a random sum of negative binomial random variables, referred to as a compound negative binomial. This tailored distribution successfully captures the width and asymmetry of the data (Fig. 3c, solid green line) and thus verifies property (ii). The improved quality of the fit can be clearly seen in the cumulative distribution functions (Fig. 3d), demonstrating larger variability than expected by traditional count statistics. This overdispersion may indicate dispersity on the bead level or dependence between the reactions of different fluorophore molecules on a particular bead, thus casting doubt on the assumption of fully random functionalization that is almost universally adopted in the field.
Estimating fluorophore locations
Not only the number of functional groups can vary between different nanoparticles, but also their spatial distribution on the particle surface. A statistical procedure has been developed to analyse the distribution of fluorophores on a nanoparticle, based on clusters of localizations as present in a dSTORM image. Since the actual locations of fluorophores are unknown in an experimental setting, the performance of this procedure has been verified using stochastic simulations (Fig. 4), validating property (iii). In these simulations, fluorophores are placed on the surface of a nanoparticle according to a pre-defined distribution (Fig. 4a). Subsequently, the dSTORM imaging process is mimicked, resulting in a localization-based image (Fig. 4b). Using this simulated image as input, first the most likely number of dyes based on the compound negative binomial distribution is calculated using the number of localizations (vide supra).
We then approximate the locations of the source fluorophores using MLE, a singular and essential step for the determination of functional group distributions. In brief, the k-means algorithm57 is applied to provide an initial guess of the source locations. Based on this initial estimate, the probability distribution of origination (i.e. the chance that a localization originates from a particular source) is derived for all localizations using MLE. Subsequently, an improved location estimate is computed using weighted contributions of localizations, taking into account the distribution of origination, the nanoparticle geometry and the measurement uncertainty (Fig. 4c, d). This last factor enables differential appraisal of bright blinks with a high localization precision, and localizations based on few photons with a larger error margin. Allocation of localizations and weighted displacement of sources are then iteratively repeated in an expectation-maximization (EM) algorithm58, until convergence is reached and a final estimate of the source locations is obtained (Fig. 4e). In a simulated environment, the actual numbers and locations of the source fluorophores are known, and can be compared to the final estimate. After matching estimates and actual locations using the Hungarian method59 assuming a known number of dyes (Fig. 4f), the absolute average estimation error can be calculated. The estimation errors in the x, y and z dimensions equal ± 21 nm (see Supplementary Table 11), thus the actual fluorophore locations can be approximated with high accuracy. A more detailed explanation and mathematical derivation of the algorithm can be found in the Supplementary Methods.
Spatial distribution of functional groups
To elucidate the functional group distribution on individual nanoparticles, Alexa647-appended particles have been investigated using the EM-estimation algorithm (Fig. 5a). The most common assumption for the functionalization process is for the fluorophore molecules to attach “fully randomly”, i.e. independently of other dyes or particle orientation. It is necessary to stress that even for fully random functionalization, stochastic variability in functional group densities along the bead is to be expected. This stochastic clustering can be conveniently quantified using the distribution of nearest-neighbour distances (NNDs)58. When the likelihood for a fluorophore to attach is constant over the surface of a nanoparticle, and thus independent of other bound dyes, the functionalization procedure can be represented as a homogeneous negative binomial point process. Thus, we have simulated a large population of beads using this “stochastically homogeneous” (from here on termed “homogeneous” for clarity) process at the appropriate average functionalization density, and have calculated the NND distribution of the functional groups (Fig. 5b, blue bars). The localization lists from these simulated beads have been subjected to the EM-algorithm, and the NND distribution for the location estimates has also been calculated (Fig. 5b, red bars). Comparison of these two distributions shows some flattening of the features below ±50 nm (the residual effect of overcounting), but the main characteristics of the NND distribution are preserved. This confirms property (iii), enabling us to draw valid inference on the NND distribution of the experimental beads.
Compared to the estimation based on the simulated dye distribution, the NND distribution for fluorophore locations obtained from the experimental images using the EM-algorithm (Fig. 5b, yellow bars) is rather different, also clearly visible in the cumulative distribution plots (Fig. 5c). One can already qualitatively conclude that the experimental data are more clustered (smaller NND) than would be expected when assuming homogeneity in the functionalization. In order to quantitatively confirm the observed deviation from homogeneity at the population level, we have performed statistical significance testing of the average NND per nanoparticle. Based on the estimated dye positions of a population of particles simulated under the homogeneity assumption (Nbeads,sim/est = 937), we have constructed an empirical distribution of the average NND per bead. For each experimentally observed particle (Nbeads,exp = 379), we have calculated the average NND of its estimated dye locations. These values are compared to the 2.5% and 97.5% quantiles of the estimated simulated (homogeneous) average NND distribution, which correspond to values that are very rare under the homogeneity assumption, and the number of observed values outside these boundaries is counted. If the homogeneous model describes the data accurately, this sum is distributed. Using α = 0.05, the threshold value for accepting homogeneity is 26 observed values outside the specified boundaries. Experimentally, we find a value of 82 (P < 0.001, tailored test, see Supplementary Table 13), leading to the rejection of homogeneity in our experimental population. The low average NND found among these outliers indicates the presence of pronounced fluctuations in functional group density, resulting in a higher degree of clustering than the stochastic clustering that might be expected for a homogeneously functionalized bead.
Effects of heterogeneity
In addition to the population-level analysis, dSTORM provides insight into the particle-to-particle variability of functional group distributions (Supplementary Figure 13). Since functionalization of nanoparticles does not take place homogeneously over the surface, finding a closed expression for the prediction of local functional group density is problematic. The exact form of the heterogeneity is unknown, may be variable with nanoparticle composition, size or functionalization chemistry, and is difficult to determine experimentally. Rather, a dSTORM-based approach can be applied to estimate fluorophore locations and empirically determine their arrangement, capturing bead-to-bead stochastic variability in the number of functional groups and their spatial distribution. As an example relevant to multivalent interactions, we quantify the presence of high-density regions on the surface of our experimental nanoparticles. Such a patch might elicit a biochemical response in a therapeutic setting or might allow displacement in competitive interactions7,41. Moreover, patchy particles may yield emergent properties and display interesting colloidal behaviour60,61. As an arbitrary threshold, we define a high-density region as the presence of five functional groups within a 50 nm arclength radius (Fig. 6a). The occurrence of these patches on the experimental nanoparticles has been quantified using our MLE procedure, showing a quantitatively different distribution and a higher average number of patches compared to the homogeneous case (Fig. 6b). Notice that the distribution for the simulated dyes (blue) illustrates the enhanced stochastic clustering of the real beads compared to their simulated counterparts. Let us assume that the presence of at least three patches results in an effective interaction. Now, based on the estimations, the probability that an arbitrary bead cannot effectively interact, , equals 0.90 for the (homogeneously) simulated beads (which is close to the probability of 0.91 underlying the simulations) and 0.60 for the experimental beads (Fig. 6b). As a consequence, on average, more than 28 homogeneously functionalized beads are required to achieve 95% probability of successful signalling , as opposed to only 6 based on the empirical distribution . When more patches are needed for effective interaction, this difference is exacerbated. Hence, these results show that the multivalent action of nanoparticles prepared through such covalent functionalization cannot be predicted correctly by assuming homogeneously reacted species, and efficacy will be likewise affected.
Discussion
An approach combining super-resolution microscopy with stochastic modelling and statistical estimation has been outlined, in which we demonstrate improved interpretation of nanoparticle surface functionality. We have verified its ability to capture the dye photophysics (i), incorporate functional group quantities (ii) and reconstruct spatial patterns (iii), and have thus proven the accurate estimation of fluorophore locations on the nanoscale. Functionalization of nanostructures is generally performed with the (implicit) aim of creating a uniform functional group pattern, but we have identified various sources of variability when applying common protocols. Stochastic fluctuations proved insufficient to explain the experimentally observed variability in dye-labelled polystyrene nanoparticles, and the common hypothesis of stochastically homogeneous (“fully random”) attachment of functionalities was rejected.
The large particle-to-particle variation in the number of functional groups and the clear heterogeneity of their distribution on the nanoparticle surface imply some measure of association between attachment events. This heterogeneity may be related to the distribution of reactive sites on the beads, to the functionalization chemistry or other factors. While its exact origin is currently unclear, it is likely prevalent in synthetic nanoparticles customized for various applications, taking into account the ubiquity and robustness of the functionalization procedures applied here. Considering the growing relevance of controlling the surface topology of functional nanoparticles in both materials science and biomedical developments62,63, elucidation of the cause and form of the heterogeneity are priorities for future research.
Of course, inhomogeneous distributions of moieties over surfaces and volumes are consequential in a wider range of artificial, as well as biological, nanosystems. The MLE based analysis of such distributions can be generalized for different probes, densities and scales, although the requirements for the algorithm may be different and hence call for optimization. Validation may be performed in silico as demonstrated here or might be accomplished using discrete reference structures with well-defined fluorophore locations (e.g. DNA origami47). Especially when the underlying molecular distribution is inaccessible, our approach is suitable for measuring probe locations and separation. In this way, it might function similarly to other clustering methods, and benchmarking relative performance and location precision might be worthwhile.
Variation in surface functionality affects multivalent interactions in therapeutic, nanotechnological and biochemical applications. It is crucial to be aware of the difference between average functionalization densities and the real, highly variable, coverage of individual nanoparticles. Controlling and harnessing this interparticle variability requires single-particle analysis of functional group densities, of which the dSTORM-based empirical analysis of high-valency regions on synthetic nanoparticles described in this work is an example. We expect that improved accessibility of such approaches will contribute to significant improvements in the design of novel functional nanostructures.
Methods
Nanoparticle labelling
Carboxylic acid functionalized polystyrene beads (Spherotech CP-025, composition: polysterene (amorphous), functionality: carboxyl, functional group content: 50 mol g−1 solid, diameter: 337 nm, zeta potential: −63.8 mV) were suspended at 0.25% w/v in phosphate-buffered saline (pH 7.2) followed by addition of 10 eq. EDC (Sigma-Aldrich, 240 μg), 25 eq. NHS (Sigma-Aldrich, 357 μg) and Alexa647-Cadaverine (Invitrogen). Single-dye beads were created using 10−6 eq. of Alexa647-Cadaverine (0.2 ng, added through a dilution series in MilliQ). Multifunctional beads of different densities were created using 10−4 (L), 10−3 (M), 10−2 (H) and 10−1 (VH) eq. of Alexa647-Cadaverine, respectively. Reactions were shaken at room temperature for 4 h. Subsequently, the beads were iteratively centrifuged and resuspended in MilliQ (three iterations), followed by extensive dialysis for 24 h (1 kDa MWCO; Spectrum Labs, three iterations).
dSTORM imaging
In order to perform dSTORM imaging, sample chambers were created as follows. Glass microscope coverslips (No. 1.0, 26 ×22 mm, thickness 0.15 mm) were consecutively immersed in acetone, isopropanol and MilliQ and sonicated for 10 min in each solvent. Next, a fresh solution of Piranha etch was prepared (3:1 v/v concentrated H2SO4:H2O2 (aq, 30%)) in which the slides were incubated for 15 min. Finally, the slides were washed thoroughly with MilliQ and acetone before drying under N2-flow. In order to introduce fiducial markers, TetraSpeck™ Microspheres (solution) were diluted 50× in ethanol, and 5 μL of this solution was placed on the coverslip. After the solution had spread over the entire surface, the ethanol was evaporated under N2-flow. Subsequently, an imaging chamber was constructed using a glass slide, two strips of double-sided tape and the coverslip. The imaging chamber was incubated with 0.1% poly-l-lysine solution (Sigma-Aldrich) for 10 min, flushed three times with MilliQ and then incubated with a suspension of Alexa647-functional nanoparticles for 30 min. After this incubation, the imaging chamber was flushed with MilliQ (three times) and dSTORM buffer (three times). dSTORM buffer contains 50 mM Tris-HCl (pH 8.0), 10 mM NaCl, 5% w/v glucose, 0.1 M MEA (mercaptoethanolamine; Sigma-Aldrich) and an oxygen scavenging system (0.5 mg per mL glucose oxidase, 40 μg per m catalase). dSTORM images were acquired using a Nikon N-STORM 4.0 system configured for total internal reflection fluorescence imaging. Alexa647-labelled nanoparticles were illuminated using a 647 nm laser; the fiducial markers were illuminated using a 488 nm laser. No UV activation was employed. Fluorescence was captured using a Nikon ×100, 1.4 NA oil immersion objective and passed through a quad-band pass dichroic filter (97335, Nikon). Images were acquired using a 256 × 256 pixel region of interest (pixel size 160 nm) on a CMOS camera. For a measurement, 50,000 frames were acquired in the 647 channel at maximum camera speed (frametime ±4 ms for this ROI on the CMOS camera). Sample imaging was alternated every 100 frames by a single 488 channel frame for drift correction. Three-dimensional acquisition was performed using the astigmatic method, calibrated by Z-stepping a sample with a high-density of fiducial markers at optimized laser intensity. dSTORM images were analysed using the dSTORM module of the NIS Elements software (Nikon). Preprocessing of the acquired data is described in the Supplementary Methods.
Probabilistic model and data simulation
The probabilistic model for the dye dynamics describes the blinking behaviour (Supplementary Figs. 2 and 3), the number of localizations per bead (Supplementary Figs. 4–6) and the observation of a signal given its source (Supplementary Eqs. 4–43 and Supplementary Figs. 7–9). The details and reasoning behind the model are presented in the Supplementary Methods. Based on this probabilistic model computer simulated beads have been generated under the assumption of homogeneous functionalization.
Estimation of dye locations
Based on the probabilistic model the number of dyes can be estimated from a collection of localizations (Supplementary Eqs. 44–46). Subsequently, an EM-algorithm is used to estimate their positions on the bead (Supplementary Eqs. 47–63). The details and reasoning behind the estimation procedure are presented in the Supplementary Methods.
Distribution analysis
The processed dSTORM images are compared with the processed simulated localization sets to ascertain homogeneous functionalization. Inference is drawn based on the average NND per bead using a modified randomization test (Supplementary Eqs. 64–67 and Supplementary Figs. 14–16). The details and reasoning behind this distribution analysis are presented in the Supplementary Methods.
Supplementary information
Acknowledgements
The work of E.W.M. is supported by the Dutch Ministry of Education, Culture and Science (Gravity program 024.001.035) and the European Research Council (FP7/2007–2013, ERC Grant Agreement 246829). The work of R.W.vdH. is supported by the Netherlands Organisation for Scientific Research (NWO) through VICI grant 639.033.806 and the Gravitation Networks grant 024.002.003. The work of L.A. is financially supported by the Spanish Ministry of Economy, Industry and Competitiveness through the Project SAF2016-75241-R (MINECO-FEDER) and by the Generalitat de Catalunya through the CERCA program. L.A. moreover acknowledge the EuroNanoMed II plataform through the project NANOVAX and the European Research Council (ERC Grant Agreement 757397). The authors thank R.M. Castro and E.R. van den Heuvel for fruitful discussions.
Author contributions
R.A.J.P. and D.vdZ. analysed the data; D.vdZ. and S.P.W.W. performed experiments; R.A.J.P. developed the algorithm and performed the simulation study; L.A, G.B., E.W.M. and R.W.vdH. supervised the research and provided advice; R.A.J.P., D.vdZ., G.B. and R.W.vdH. wrote the Supplementary Information and R.A.J.P., D.vdZ., L.A., E.W.M. and R.W.vdH. wrote the manuscript.
Data availability
The data that support the findings of this study are available from the corresponding author upon reasonable request.
Code availability
The R code of the EM-algorithm is available from the corresponding author on reasonable request.
Competing interests
The authors declare no competing interests.
Footnotes
Journal Peer Review Information: Nature Communications thanks the anonymous reviewer(s) for their contribution to the peer review of this work.
Publisher’s note: Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
These authors contributed equally: R.A.J. Post, D. van der Zwaag.
Contributor Information
E. W. Meijer, Email: e.w.meijer@tue.nl
R. W. van der Hofstad, Email: r.w.v.d.hofstad@tue.nl
Supplementary information
Supplementary Information accompanies this paper at 10.1038/s41467-019-09595-y.
References
- 1.Newton AC, Groenewold J, Kegel WK, Bolhuis PG. The role of multivalency in the association kinetics of patchy particle complexes. J. Chem. Phys. 2017;146:1–10. doi: 10.1063/1.4984966. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 2.Rogers WB, Shih WM, Manoharan VN. Using DNA to program the self-assembly of colloidal nanoparticles and microparticles. Nat. Rev. Mater. 2016;1:16008. doi: 10.1038/natrevmats.2016.8. [DOI] [Google Scholar]
- 3.Kim Y, Macfarlane RJ, Jones MR, Mirkin CA. Transmutable nanoparticles with reconfigurable surface ligands. Science. 2016;351:579–582. doi: 10.1126/science.aad2212. [DOI] [PubMed] [Google Scholar]
- 4.Wang Y, et al. Colloids with valence and specific directional bonding. Nature. 2012;491:51–55. doi: 10.1038/nature11564. [DOI] [PubMed] [Google Scholar]
- 5.Gerth M, Voets IK. Molecular control over colloidal assembly. Chem. Commun. 2017;53:4414–4428. doi: 10.1039/C6CC09985H. [DOI] [PubMed] [Google Scholar]
- 6.Fasting C, et al. Multivalency as a chemical organization and action principle. Angew. Chem. Int. Ed. 2012;51:10472–10498. doi: 10.1002/anie.201201114. [DOI] [PubMed] [Google Scholar]
- 7.Badjic JD, Nelson A, Cantrill SJ, Turnbull WB, Fraser Stoddart J. Multivalency and cooperativity in supramolecular chemistry. Acc. Chem. Res. 2005;38:723–732. doi: 10.1021/ar040223k. [DOI] [PubMed] [Google Scholar]
- 8.Hunter CA, Anderson H. What is cooperativity? Angew. Chem. Int. Ed. 2009;48:7488–7499. doi: 10.1002/anie.200902490. [DOI] [PubMed] [Google Scholar]
- 9.Ercolani G, Schiaffino L. Allosteric, chelate, and interannular cooperativity: a mise au point. Angew. Chem. Int. Ed. 2011;50:1762–1768. doi: 10.1002/anie.201004201. [DOI] [PubMed] [Google Scholar]
- 10.Albertazzi L, et al. Spatiotemporal control and superselectivity in supramolecular polymers using multivalency. Proc. Natl Acad. Sci. USA. 2013;30:12203–12208. doi: 10.1073/pnas.1303109110. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 11.Wu H. Higher-order assemblies in a new paradigm of signal transduction. Cell. 2013;153:287–292. doi: 10.1016/j.cell.2013.03.013. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 12.Kiessling LL, Gestwicki JE, Strong LE. Synthetic multivalent ligands as probes of signal transduction. Angew. Chem. Int. Ed. 2006;45:2348–2368. doi: 10.1002/anie.200502794. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 13.Kamaly N, Xiao Z, Valencia PM, Radovic-Moreno AF, Farokhzad OC. Targeted polymeric therapeutic nanoparticles: design, development and clinical translation. Chem. Soc. Rev. 2012;41:2971–3010. doi: 10.1039/c2cs15344k. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 14.Dalal C, Saha A, Jana NR. Nanoparticle multivalency directed shifting of cellular uptake mechanism. J. Phys. Chem. C. 2016;12:6778–6786. doi: 10.1021/acs.jpcc.5b11059. [DOI] [Google Scholar]
- 15.Banani SF, Lee HO, Hyman AA, Rosen MK. Biomolecular condensates: organizers of cellular biochemistry. Nat. Rev. Mol. Cell Biol. 2017;18:285–298. doi: 10.1038/nrm.2017.7. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 16.Sapsford KE, Tyner KM, Dair BJ, Deschamps JR, Medintz I. Analyzing nanomaterial bioconjugates: a review of current and emerging purification and characterization techniques. Anal. Chem. 2011;83:4453–4488. doi: 10.1021/ac200853a. [DOI] [PubMed] [Google Scholar]
- 17.Elowitz MB, Levine AJ, Siggia ED, Swain PS. Stochastic gene expression in a single cell. Science. 2002;297:1183–1186. doi: 10.1126/science.1070919. [DOI] [PubMed] [Google Scholar]
- 18.Satija R, Shalek AK. Heterogeneity in immune responses: from populations to single cells. Trends Immunol. 2014;35:219–229. doi: 10.1016/j.it.2014.03.004. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 19.Pengo P, et al. Gold nanoparticles with patterned surface monolayers for nanomedicine: current perspectives. Eur. Biophys. J. 2017;46:749–771. doi: 10.1007/s00249-017-1250-6. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 20.Smith JR, Olusanya TOB, Lamprou DA. Characterization of drug delivery vehicles using atomic force microscopy: current status. Exp. Opin. Drug Deliv. 2018;15:1211–1221. doi: 10.1080/17425247.2018.1546693. [DOI] [PubMed] [Google Scholar]
- 21.Lu A, et al. Unified polymerization mechanism for the assembly of ASC-dependent inflammasomes. Cell. 2014;156:1193–1206. doi: 10.1016/j.cell.2014.02.008. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 22.Kelly PM. Mapping protein binding sites on the biomolecular corona of nanoparticles. Nat. Nanotechnol. 2015;10:472–479. doi: 10.1038/nnano.2015.47. [DOI] [PubMed] [Google Scholar]
- 23.Schermelleh L, Heintzmann R, Leonhardt H. A guide to super-resolution fluorescence microscopy. J. Cell Biol. 2010;190:165–175. doi: 10.1083/jcb.201002018. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 24.Liu Z, Lavis LD, Betzig E. Imaging live-cell dynamics and structure at the single-molecule level. Mol. Cell. 2015;58:644–659. doi: 10.1016/j.molcel.2015.02.033. [DOI] [PubMed] [Google Scholar]
- 25.Sydor AM, Czymmek KJ, Puchner EM, Mennella V. Super-resolution microscopy: from single molecules to supramolecular assemblies. Trends Cell Biol. 2015;25:730–748. doi: 10.1016/j.tcb.2015.10.004. [DOI] [PubMed] [Google Scholar]
- 26.Biteen J, Willets KA. Introduction: super-resolution and single-molecule imaging. Chem. Rev. 2017;117:7241–7243. doi: 10.1021/acs.chemrev.7b00242. [DOI] [PubMed] [Google Scholar]
- 27.Xu K, Zhong G, Zhuang X. Actin, spectrin and associated proteins form a periodic cytoskeletal structure in axons. Science. 2013;339:452–456. doi: 10.1126/science.1232251. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 28.Nixon-Abell J, et al. Increased spatiotemporal resolution reveals highly dynamic dense tubular matrices in the peripheral ER. Science. 2016;354:1–12. doi: 10.1126/science.aaf3928. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 29.Boott CE, et al. In situ visualization of block copolymer self-assembly in organic media by super-resolution fluorescence microscopy. Chem. Eur. J. 2015;21:18539–18542. doi: 10.1002/chem.201504100. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 30.Da Silva RMP, et al. Super-resolution microscopy reveals structural diversity in molecular exchange among peptide amphiphile nanofibers. Nat. Commun. 2016;7:11561. doi: 10.1038/ncomms11561. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 31.Feiner-Gracia N, et al. Super-resolution microscopy unveils dynamic heterogeneities in nanoparticle protein corona. Small. 2017;13:1701631. doi: 10.1002/smll.201701631. [DOI] [PubMed] [Google Scholar]
- 32.Pujals S, Tao K, Terradellas A, Gazit E, Albertazzi L. Studying structure and dynamics of self-assembled peptide nanostructures using fluorescence and super-resolution microscopy. Chem. Commun. 2017;53:7294–7297. doi: 10.1039/C7CC02176C. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 33.Vandenberg W, Leutenegger M, Lasser T, Hofkens J, Dedecker P. Diffraction-unlimited imaging: from pretty pictures to hard numbers. Cell Tissue Res. 2015;360:151–178. doi: 10.1007/s00441-014-2109-0. [DOI] [PubMed] [Google Scholar]
- 34.Durisic N, Laparra Cuervo L, Lakadamyali M. Quantitative super-resolution microscopy: pitfalls and strategies for image analysis. Curr. Opin. Chem. Biol. 2014;20:22–28. doi: 10.1016/j.cbpa.2014.04.005. [DOI] [PubMed] [Google Scholar]
- 35.Baddeley D, Bewersdorf J. Biological insight from super-resolution microscopy: what we can learn from localization-based images. Ann. Rev. Biochem. 2018;87:1. doi: 10.1146/annurev-biochem-060815-014801. [DOI] [PubMed] [Google Scholar]
- 36.Jungmann R, et al. Quantitative super-resolution imaging with qPAINT. Nat. Methods. 2016;13:439–442. doi: 10.1038/nmeth.3804. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 37.Jung SR, Fujimoto BS, Chiu DT. Quantitative microscopy based on single-molecule fluorescence. Curr. Opin. Chem. Biol. 2017;39:64–79. doi: 10.1016/j.cbpa.2017.06.004. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 38.Karathanasis C, Fricke F, Hummer G, Heilemann M. Molecule counts in localization microscopy with organic fluorophores. Chemphyschem. 2017;18:942–948. doi: 10.1002/cphc.201601425. [DOI] [PubMed] [Google Scholar]
- 39.Lee SH, Shin JY, Lee A, Bustamante C. Counting single photoactivatable fluorescent molecules by photoactivated localization microscopy (PALM) Proc. Natl Acad. Sci. USA. 2012;109:17436–17441. doi: 10.1073/pnas.1215175109. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 40.Pengo T, Holden SJ, Manley S. PALMsiever: a tool to turn raw data into results for single-molecule localization microscopy. Bioinformatics. 2015;31:797–798. doi: 10.1093/bioinformatics/btu720. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 41.Veatch SL, et al. Correlation functions quantify super-resolution images and estimate apparent clustering due to over-counting. PLoS ONE. 2012;7:1–13. doi: 10.1371/journal.pone.0031457. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 42.Nieuwenhuizen RPJ, et al. Quantitative localization microscopy: effects of photophysics and labeling stoichiometry. PLoS ONE. 2015;10:1–18. doi: 10.1371/journal.pone.0127989. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 43.Schmidt T, Schütz GJ, Gruber HJ, Schindler H. Local stoichiometries determined by counting individual molecules. Anal. Chem. 1996;68:4397–4401. doi: 10.1021/ac960710g. [DOI] [Google Scholar]
- 44.Finan K, Raulf A, Heilemann M. A set of homo-oligomeric standards allows accurate protein counting. Angew. Chem. Int. Ed. 2015;54:12049–12052. doi: 10.1002/anie.201505664. [DOI] [PubMed] [Google Scholar]
- 45.Fricke F, Beaudouin J, Eils R, Heilemann M. One, two or three? Probing the stoichiometry of membrane proteins by single-molecule localization microscopy. Sci. Rep. 2015;5:14072. doi: 10.1038/srep14072. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 46.Hummer G, Fricke F, Heilemann M. Model-independent counting of molecules in single-molecule localization microscopy. Mol. Biol. Cell. 2016;27:3637–3644. doi: 10.1091/mbc.e16-07-0525. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 47.Cella Zanacchi F, et al. A DNA origami platform for quantifying protein copy number in super-resolution. Nat. Methods. 2017;14:789–792. doi: 10.1038/nmeth.4342. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 48.Rubin-Delanchy P, et al. Bayesian cluster identification in single-molecule localization microscopy data. Nat. Methods. 2015;12:1072–1076. doi: 10.1038/nmeth.3612. [DOI] [PubMed] [Google Scholar]
- 49.Griffié, J., et al. 3D Bayesian cluster analysis of super-resolution data reveals LAT recruitment to the T cell synapse. Sci. Rep.7, 4077 (2017). [DOI] [PMC free article] [PubMed]
- 50.Thompson RE, Larson DR, Webb WW. Precise nanometer localization analysis for individual fluorescent probes. Biophys. J. 2002;82:2775–2783. doi: 10.1016/S0006-3495(02)75618-X. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 51.Dempsey GT, Vaughan JC, Hao Chen K, Bates M, Zhuang X. Evaluation of fluorophores for optimal performance in localization-based super-resolution imaging. Nat. Methods. 2011;8:1027–1036. doi: 10.1038/nmeth.1768. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 52.Nie S, Chiu DT, Zare RN. Probing individual molecules with confocal fluorescence microscopy. Science. 1994;266:1018–1021. doi: 10.1126/science.7973650. [DOI] [PubMed] [Google Scholar]
- 53.Chozinski TJ, Gagnon LA, Vaughan JC. Twinkle, twinkle, little star: photoswitchable fluorophores for super-resolution imaging. FEBS Lett. 2014;588:3603–3612. doi: 10.1016/j.febslet.2014.06.043. [DOI] [PubMed] [Google Scholar]
- 54.Van de Linde S, Sauer M. How to switch a fluorophore: from undesired blinking to controlled photoswitching. Chem. Soc. Rev. 2014;43:1076–1087. doi: 10.1039/C3CS60195A. [DOI] [PubMed] [Google Scholar]
- 55.Mortenson KI, Stirling Churchman L, Spudich JA, Flyvbjerg H. Optimized localization-analysis for single-molecule tracking and super-resolution microscopy. Nat. Methods. 2010;7:377–381. doi: 10.1038/nmeth.1447. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 56.Stallinga S, Rieger B. Accuracy of the Gaussian Point Spread Function model in 2D localization microscopy. Opt. Express. 2010;18:24461–24476. doi: 10.1364/OE.18.024461. [DOI] [PubMed] [Google Scholar]
- 57.Hartigan JA, Wong MA. A K-means clustering algorithm. Appl. Stat. 1979;28:100–108. doi: 10.2307/2346830. [DOI] [Google Scholar]
- 58.Duda RO, Hart PE, Stork DG. Pattern Classification. Chichester: Wiley-Interscience; 2001. [Google Scholar]
- 59.Kuhn HW. The Hungarian method for the assignment problem. Nav. Res.Logist. 2005;52:7–21. doi: 10.1002/nav.20053. [DOI] [Google Scholar]
- 60.Kraft DJ, et al. Surface roughness directed self-assembly of patchy particles into colloidal micelles. Proc. Natl Acad. Sci. USA. 2012;109:10787–10792. doi: 10.1073/pnas.1116820109. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 61.Evers CHJ, Luikens JA, Bolhuis PG, Kegel WK. Self-assembly of microcapsules via colloidal bond hybridization and anisotropy. Nature. 2016;534:364–368. doi: 10.1038/nature17956. [DOI] [PubMed] [Google Scholar]
- 62.Patiño T, et al. Influence of enzyme quantity and distribution on the self-propulsion of non-janus urease-powered micromotors. J. Am. Chem. Soc. 2018;140:7896–7903. doi: 10.1021/jacs.8b03460. [DOI] [PubMed] [Google Scholar]
- 63.Delcanale P, Miret-Ontiveros B, Arista-Romero M, Pujals S, Albertazzi L. Nanoscale mapping functional sites on nanoparticles by points accumulation for imaging in nanoscale topography (PAINT) ACS Nano. 2018;12:7629–7637. doi: 10.1021/acsnano.7b09063. [DOI] [PubMed] [Google Scholar]
Associated Data
This section collects any data citations, data availability statements, or supplementary materials included in this article.
Supplementary Materials
Data Availability Statement
The data that support the findings of this study are available from the corresponding author upon reasonable request.
The R code of the EM-algorithm is available from the corresponding author on reasonable request.