Abstract
Background
Physical capacity tasks (ie, observer-administered outcome measures that comprise a standardized activity) are useful for assessing functioning in patients with low back pain.
Purpose
The purpose of this study was to systematically review the level of evidence for the reliability, validity, and responsiveness of physical capacity tasks.
Data Sources
MEDLINE, CINAHL, PsycINFO, Scopus, the Cochrane Library, and relevant reference lists were used as data sources.
Study Selection
Two authors independently selected articles addressing the reliability, validity, and responsiveness of physical capacity tasks, and a third author resolved discrepancies.
Data Extraction and Quality Assessment
One author performed data extraction, and a second author independently checked the data extraction for accuracy. Two authors independently assessed the methodological quality with the Consensus-Based Standards for the Selection of Health Measurement Instruments (COSMIN) 4-point checklist, and a third author resolved discrepancies.
Data Synthesis and Analysis
Data synthesis was performed by all authors to determine the level of evidence per measurement property per physical capacity task. The 5-repetition sit-to-stand, 5-minute walk, 50-ft (∼15.3-m) walk, Progressive Isoinertial Lifting Evaluation, and Timed “Up & Go” tasks displayed moderate to strong evidence for positive ratings of both reliability and construct validity. The 1-minute stair-climbing, 5-repetition sit-to-stand, shuttle walking, and Timed “Up & Go” tasks showed limited evidence for positive ratings of responsiveness.
Limitations
The COSMIN 4-point checklist was originally developed for patient-reported outcome measures and not physical capacity tasks.
Conclusions
The 5-repetition sit-to-stand, 50-ft walk, 5-minute walk, Progressive Isoinertial Lifting Evaluation, Timed “Up & Go,” and 1-minute stair-climbing tasks are promising tests for the measurement of functioning in patients with chronic low back pain. However, more research on the measurement error and responsiveness of these tasks is needed to be able to fully recommend them as outcome measures in research and clinical practice.
Research suggests that low back pain (LBP) causes more years lived with disability than any other condition.1 Many patients with acute LBP recover quickly, but the pain becomes a chronic condition for some, with significant consequences related to restricted functioning.2 The measurement of functioning is complex and covers multidimensional constructs.3 Functioning is divided into 3 domains according to the International Classification of Functioning, Disability, and Health (ICF). The body functions and structures domain refers to psychological and physiological processes and anatomical structures; the activity domain refers to people's ability to perform activities in their daily life; and the participation domain describes people's interactions with their sociocultural environment (eg, when buying groceries, participating in sports, or working).3 Researchers have argued for the use of outcome measures that specifically measure functioning in the activity domain.4–6
The ICF activity domain is typically measured with patient-reported outcome measures (PROMs), with which patients rate their perceived ability to perform various activities in their usual environment.7–11 PROMs are relatively time saving, easy to administer, and, importantly, include the patient's perspective.12 However, PROMs as used in LBP research have shown both floor and ceiling effects as well as low- to very-low-quality evidence for content validity.13,14 Clinical experience and scientific evidence also indicate frequent discrepancies between how patients score PROMs and how they actually move and perform activities when observed in the clinic.15–17 Several authors5,6,16–18 have therefore recommended the use of physical capacity tasks that measure the capacity qualifier of the ICF activity domain,5,6,16–18 defined as “the ability to execute a task or an action in a standardized environment.”3 In a physical capacity task, a patient performs a standardized activity that is administered by an observer using predefined criteria such as repetition counts or task timing.18
Physical capacity tasks are designed to assess what patients actually can do rather than what they think they can do, and can therefore capture important information about functioning that PROMs often do not.17,19,20 Physical capacity tasks also appear to be less influenced by education level and language skills compared with PROMs.17,18,21,22
All outcome measures should have sufficient support for their reliability, validity, and responsiveness in order to be used in research or in clinical practice. Otherwise, there is a significant risk of imprecise or biased results that might lead to incorrect conclusions regarding the patient's level of functioning.23–25 However, to our knowledge, no study has yet summarized the level of evidence of measurement properties of physical capacity tasks for patients with LBP.
The objective of this study was to systematically review the level of evidence of the measurement properties of physical capacity tasks that are designed to assess functioning in patients with LBP.
Methods
The study protocol was registered at the International Prospective Register of Systematic Reviews (PROSPERO; http://www.crd.york.ac.uk/PROSPERO; registration number: CRD42016042011). We followed the working procedure developed by the Consensus-Based Standards for the Selection of Health Measurement Instruments (COSMIN) for conducting a systematic review of measurement properties.23 The systematic review was reported according to the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA).26
Data Sources and Searches
The electronic data sources were MEDLINE (through the Ovid interface), CINAHL (EBSCOhost), PsycINFO (Ovid), Scopus (Elsevier), and the Cochrane Library (Wiley). The reference lists of the articles from the electronic data sources that were identified for full-text reading were used as additional data sources.
A search strategy was developed in collaboration with 2 medical librarians who also performed the search (eAppendix 1, available at https://academic.oup.com/ptj). The search strategy included 4 main filters, specifically tailored for each electronic information source: target population (ie, LBP), the construct of interest (ie, capacity), type of outcome measures (ie, physical capacity tasks), and article type (ie, articles on the reliability, validity, and responsiveness of outcome measures). The search strategy was based on a preliminary search strategy as described in the PROSPERO protocol. Improvements of the preliminary search strategy included: (1) adaptation of a validated search filter for measurement properties;27 (2) addition of the specific names of all physical capacity tasks identified by the preliminary search strategy; (3) use of the Ovid interface rather than PubMed for MEDLINE due to the benefit of positional operators; and (4) the addition of supplementary search terms for LBP. The first search with the final search strategy was performed on May 11, 2017 (no limitations for publication period) and an updated search was performed on August 29, 2018 (publication period from January 1, 2016). No restrictions were applied for language. Two authors (M.J. and either A.G. or M.L.) independently performed a hand search of the reference lists of all articles that had been identified for full-text reading.
Study Selection
Two authors (M.J. and either A.G. or M.L.) independently screened the titles and abstracts of articles from the electronic and hand searches. A third author (R.S.) was consulted to resolve the disagreement if consensus could not be reached on the eligibility of articles for full-text review. Two authors (M.J. and A.G., R.S., or M.L.) then independently reviewed the full-text articles for eligibility, and a third author (A.G., R.S., or M.L.) was consulted if needed for consensus.
Articles that met 4 criteria (target population, construct, outcome measure, and article type) were included.
Target population
Patients in the study population were at least 18 years old and had had LBP for 6 weeks or more.28 Articles that contained pregnant participants or participants with fibromyalgia, confirmed rheumatic diseases, infections, tumors, osteoporosis, fractures, structural deformities (eg, scoliosis), or cauda equina syndrome were excluded unless data were presented specifically for patients who met the eligibility criteria.
Construct
The test was a measure of “capacity” under the ICF activity domain, defined as the ability to execute a task or an action in a standardized environment.3
Outcome measure
The test was a physical capacity task, defined as a standardized test that is used for an evaluative purpose and that is administered by an observer, includes an activity (as classified by the ICF) that is performed in a standardized setting, and requires readily available, low-cost, and portable equipment. Articles that exclusively investigated test batteries and did not present results for individual physical capacity tasks were excluded. If an article cited an original test manual that could then not be obtained, the test was excluded.
Article type
The article presented original data reporting the reliability (including reliability, measurement error, and internal consistency), validity (including content validity, construct validity, and criterion validity), or responsiveness of physical capacity tasks.29
Data Extraction and Quality Assessment
A pilot version of a data extraction form was developed by the first author (M.J.) and piloted by 3 authors (M.J., R.S., and M.L.) on 5 randomly selected, included articles. The data extraction form was modified in response to the pilot to include the following 6 data items: (1) patient sample characteristics; (2) eligibility criteria; (3) setting; (4) procedure and equipment for performing the physical capacity tasks; (5) results of the measurement properties, and (6) minimal important change. Minimal important change is not considered a measurement property in the COSMIN taxonomy29 but was included in the data extraction form because this measure is necessary to determine the level of evidence for measurement error.30 Data from all included articles were subsequently extracted by 1 author (M.J.) and then independently checked for accuracy by a second author (A.G., R.S., or M.L.).
Two authors (M.J. and M.L.) independently assessed all of the included studies for methodological quality using the COSMIN 4-point checklist,31,32 and a third author (A.G., R.S., or L.B.M.) was consulted if needed to reach consensus. The COSMIN 4-point checklist is specifically designed to determine methodological quality scores of studies of measurement properties. The scores (excellent, good, fair, or poor) are assigned for each measurement property using the “worst score counts method.”31,32 The item for sample size in the checklist was excluded from the “worst score counts method” as recommended when performing systematic reviews of measurement properties of physical capacity tasks.33 The rating authors (M.J. and M.L.) pretested and then discussed the ratings of the checklist with a third author (L.B.M.) to achieve consistency in scoring, as recommended to ensure the validity of the scoring method.34
Data Synthesis and Analysis
A “best-evidence synthesis” approach was performed by consensus of all authors to synthesize the level of evidence of measurement properties per physical capacity task.35 This procedure is similar to the Grading of Recommendations Assessment, Development, and Evaluation (GRADE),36 but different in that the best-evidence synthesis determines the level of evidence for the results of measurement properties, rather than the results of clinical trials.23 First, the results of each measurement property for each physical capacity task were rated as “positive,” “negative,” or “indeterminate” according to result rating criteria accepted with consensus in an international Delphi study (Tab. 1).30 Then, the level of evidence for the ratings of measurement properties was determined on the basis of the consistency of the result ratings of the measurement properties, the sample size of the combined eligible articles, and the methodological quality of the articles. Multiple articles were combined if they concerned the same physical capacity task and included samples with comparable characteristics. The possible levels of evidence were assigned according to 5 criteria (strong, moderate, limited, unknown, and conflicting) used in previous systematic reviews of the reliability, validity, and responsiveness of physical capacity tasks.33,35
Table 1.
Criteria for Result Ratings of Measurement Propertiesa
| Measurement Property | Ratingb | Criterion for Result Rating |
|---|---|---|
| Reliability | + | ICC or weighted κ ≥0.70 |
| ? | ICC or weighted κ not reported | |
| − | Criteria for “+” not met | |
| Measurement error | + | SDC or LoA < MICc |
| ? | MIC not defined | |
| − | Criteria for “+” not met | |
| Hypothesis testing for construct validity | + | 75% of the results in accordance with the hypotheses |
| ? | No hypotheses defined | |
| − | Criteria for “+” not met | |
| Criterion validity | + | Correlation with gold standard ≥ 0.70 or AUC ≥ 0.70 |
| ? | Not all information for “+” reported | |
| − | Criteria for “+” not met | |
| Responsiveness | + | 75% of the results in accordance with the hypotheses or AUC ≥ 0.70 |
| ? | No hypotheses defined | |
| − | Criteria for “+” not met |
aBased on Prinsen et al.30 AUC = area under the receiver operating characteristic curve; ICC = intraclass correlation coefficient; LoA = limits of agreement; MIC = minimal important change; SDC = smallest detectable change.
b+ = positive rating; ? = indeterminate rating; − = negative rating.
cThis evidence can come from different studies.
Strong
This criterion encompassed consistent result ratings in at least 2 good-quality articles or at least 1 excellent-quality article, with a total sample size of eligible articles equal to or greater than 100.
Moderate
This criterion encompassed consistent result ratings in at least 2 fair-quality articles or 1 good-quality article, with a total sample size of eligible articles equal to or greater than 50.
Limited
This criterion encompassed at least 1 fair-, good-, or excellent-quality article, with a total sample size of eligible articles of 25 to 49.
Unknown
This criterion encompassed the following 4 options: indeterminate result ratings, all eligible articles were of poor methodological quality, the total sample size of eligible articles was less than 25, or conflicting result ratings.
Conflicting
This criterion encompassed conflicting findings.
If an article lacked a priori hypotheses for validity and responsiveness, we extracted what the authors had expected in relation to those measurement properties from the description found in the article. We generated our own hypotheses for validity and responsiveness based on these descriptions, which were then added to the data synthesis (eAppendixes 2 and 3, available at https://academic.oup.com/ptj).
Role of the Funding Source
This review was supported by AFA Försäkring 120216, the Eurospine Research Grants 8-2014, the Health and Medical Care Executive Board of the Västra Götaland Region, and Vetenskapsrådet 2015-02511. The funders played no role in the study design, data analysis, interpretation of data, or writing of the manuscript. The views expressed here are those of the authors and do not necessarily reflect those of the funding sources.
Results
Study Selection and Characteristics
The search of electronic data sources and the hand search of reference lists resulted in 7900 articles after duplicates had been removed (Figure). Of these, 25 articles fulfilled the eligibility criteria (Tab. 2). The included articles comprised 18 physical capacity tasks that involved the following activities: walking (10 tasks), stair-climbing (1 task), lifting (3 tasks), rising from a chair (2 tasks), a combination of walking/rising from a chair (1 task), and a combination of walking and carrying (1 task) (Tab. 3).
Figure.
Flow of information through the different phases of the systematic review.
Table 2.
Characteristics of Included Studies in Alphabetical Order of First Authors’ Namesa
| Study | Criteria for Patient Inclusion | Sample Size (% Women) | Age, Mean (SD) [Range] | Setting (Country) | Back Pain Durationb | Back Pain Intensityb | Patient-Reported Disability, Mean (SD) | Eligible Physical Capacity Task |
|---|---|---|---|---|---|---|---|---|
| Andersson et al51 (2010) | Nonspecific LBP for >3 mo | 198 (47) | 41.9 (9.1) | Tertiary care (the Netherlands) | Median: 24.0 mo (IQR: 12.0–73.0 mo) | VAS: 48.9 (24.7) | RMDQ: 13.8 (3.6) | 1 min of stair climbing, 5-min walk, 50-ftc walk, PILE, sit-to-stand |
| Armstrong et al52 (2005) | LBP for ≥6 mo | 10 (80) | 40.8 (11.3) | Tertiary care (United Kingdom) | 77.1 (35.8) mo | VAS: 46 (23) | Shuttle walking test | |
| Campbell et al38 (2006) | LBP for >12 mo, considered for surgical stabilization of the spine (unspecified LBP, spondylolisthesis, or postlaminectomy) | 250 (44) | 40 (8.7) [19–55] | Hospitals (United Kingdom) | 7.6 (6.7) y | ODI for improved: 42.6 (13.6); ODI for stable: 46.8 (13.7); ODI for deteriorated: 51.8 (13.5) | Shuttle walking test | |
| Conway et al20 (2011) | Lumbar spinal stenosis | 12 (25) | 66.3 (9.8) [53–81] | Tertiary care (United States) | 4.7 (1.5) y | VAS: 39.9 (27.0) | ODI: 48.9 (11.6); QBPDS: 48.2 (16.8) | Self-paced walking test |
| Deen et al39 (2000) | Lumbar spinal stenosis | 28 (39.3) | 73.8 [57–91] | Treadmill examination (only the test parameter “total ambulation”) | ||||
| Gautschi et al15 (2016) | Lumbar disk herniation, lumbar spinal stenosis, and lumbar degenerative disk disease scheduled for lumbar spine surgery | 253 (42.3) | 58.4 (16.1) | Hospitals (Switzerland) | VAS: 39.1 (28.5); VAS for the leg: 48.8 (29.0) | RMDQ: 11.8 (5.2); ODI: 48.4 (20.8) | Timed “Up & Go” Test | |
| Gautschi et al45 (2016) | Lumbar disk herniation, lumbar spinal stenosis, and lumbar degenerative disk disease scheduled for lumbar spine surgery | 136 (44.1) | 57.7 (15.8) | Hospitals (Switzerland) | VAS: 45.6 (17.6); VAS for the leg: 5.5 (2.6) | ODI: 45.6 (17.6); RMDQ: 11.3 (5.1) | Timed “Up & Go” Test | |
| Gautschi et al44 (2017) | Lumbar disk herniation, lumbar spinal stenosis, and lumbar degenerative disk disease scheduled for lumbar spine surgery | 100 (43) | 56.2 (16.1) | Hospitals (Switzerland) | VAS: 38.0 (10); VAS for the leg: 55.0 (28) | RMDQ: 12 (5); ODI: 46 (18) | Timed “Up & Go” Test | |
| Kahraman et al47 (2016) | Nonspecific LBP for >12 wk | 38 (37) | 35 (10) | 7 (3) mo | VAS with rest: 21.3 (15.1); VAS with activity: 64.5 (20.1) | ODI: 22.6 (14.2) | 30-s chair stand test | |
| Lee et al19 (2001) | LBP with mechanical, structural, or nonspecific origins | 83 (57.8) | 45.64 (10.12) [24–65] | Orthopedic spine clinic (United States) | 108.2 (127.9) mo | VAS: 36.9 (27.0) | RMDQ: 10.4 (6.1) | 5-min walk, 50-ft walk, 5-repetition sit-to-stand |
| Magnussen et al37 (2004) | LBP for >8 wk | 32 (66%) | 38.1 (9.2) | Tertiary care (Norway) | RMDQ: 10.0 (4.0); FFbH-R: 22.5 (4.9) | Lift test | ||
| Ocarino et al53 (2009) | Nonspecific LBP for ≥3 mo | 30 | 43.16 (11.23) | University clinic (Brazil) | 42.3 (80.6) mo | RMDQ: 9.9 (3.7) | 50-ft walk, sit-to-stand | |
| Odebiyi et al54 (2007) | LBP for ≥3 mo with radiating leg pain | 23 | [25–65] | Two hospitals (Nigeria) | VAS for men: 45.2 (19.4); VAS for women: 64.1 (22.4) | RMDQ for men: 8.4 (5.3); RMDQ for women: 9.6 (4.9) | 50-ft walk, 5-min walk, 5-repetition sit-to-stand | |
| Pratt et al40 (2002) | Lumbar spinal stenosis | 29 (41) | 69 [49–82] | Orthopedic hospital (United Kingdom) | ODI: 39.8 (16.5) | Shuttle walking test | ||
| Rainville et al41 (2012) | Lumbar spinal stenosis | 50 (42) | 68 (7.9) [48–86] | Spine center of a hospital (United States) | VAS: 61; VAS for the leg: 54 | ODI: 35 | Motorized treadmill test, self-paced walking test | |
| Simmonds et al17 (1998) | Nonspecific, mechanical LBP | 44 (63.6) | 42.6 | Orthopedic clinic (United States) | 12.4 (20.8) [1–72] mo | VAS: 27.3 (23.9) [0.0–7.2] | RMDQ: 8.3 (6.0) | 1 min of stair climbing, 5-min walk, 50-ft walk, 50-ft walk (preferred speed), 5-repetition sit-to-stand |
| Smeets et al5 (2006) | Nonspecific LBP for >3 mo | 53 (52.8) | 43.19 (9.27) | Tertiary care (the Netherlands) | 53.4 (67.7) mo | VAS: 44.5 (23.5) | RMDQ: 13.2 (4.2) | 1-min of stair climbing, 5-min walk, 50-ft walk, PILE, 5-repetition sit-to-stand |
| Soer et al55 (2006) | LBP for >3 mo | 53 (39.6) | 38.5 (9.8) | 250 (375) wk | RMDQ: 9.2 (5.5) | PILE | ||
| Staartjes and Schroder46 (2018) | Lumbar disk herniation, lumbar spinal stenosis, spondylolisthesis, degenerative disk disease | 157 (49) | 49.9 (14.1) | Outpatient spine surgery clinic (the Netherlands) | VAS: 5.8 (2.8); VAS for the leg: 7.4 (2.0) | ODI: 43.0 (17.6); RMDQ: 11.7 (5.3) | 5-repetition sit-to-stand | |
| Strand et al56 (2002) | LBP for >3 mo | 114 (60) | 43.9 (10.6) | Tertiary care (Norway) | 10 (9.0) y | VAS: 52.6 (20.5) | Disability Rating Index: 56.2 (13.3) | Lift test |
| Strand et al48 (2011) | LBP for >3 mo | 98 (49.0) | 37.4 (10.4) [18–60] | Tertiary care (Norway) | RMDQ: 11.8 (4.4); FFbH-R: 7.9 (5.3) | 15-m walk test, lift test (modified), PILE | ||
| Taylor et al49 (2001) | Mechanical LBP with or without sciatica for ≥6 mo | 44 (59.2) | 48.2 (9.1) | Tertiary care (Great Britain) | ODI: 28.5 | |||
| Teixeira da Cunha-Filho et al50 (2010) | LBP for >3 mo | 30 (63.3) | 33.0 (10.6) | Tertiary care (Brazil) | VAS: 44 (26) | RMDQ: 9.8 (5.8) | 50-ft walk, 5-min walk, 5-repetition sit-to-stand, Timed “Up & Go” Test | |
| Tomkins et al42 (2009) | Lumbar spinal stenosis | 45 (57.8) | 66.9 (9.6) | 10 (11) y; leg pain: 7 (9) y | Self-paced walking test, treadmill protocol | |||
| Whitehurst et al43 (2001) | Lumbar spinal stenosis | 57 (56.1) | Men: 69 (5); women: 70 (3) | Treadmill walking test, weight-carrying test |
aFFbH-R = Hannover Functional Ability Questionnaire; IQR = interquartile range; LBP = low back pain; ODI = Oswestry Disability Index; PILE = Progressive Isoinertial Lifting Evaluation; QBPDS = Quebec Back Pain Disability Scale; RMDQ = Roland-Morris Disability Questionnaire; SD = standard deviation; VAS = 100-mm visual analog scale.
bReported as mean (SD) [range] unless otherwise indicated.
c50 ft ≈ 15.3 m.
Table 3.
Brief Descriptions of Included Physical Capacity Tasks
| Physical Capacity Task | Activity | Quantification Measure | Equipment Needed |
|---|---|---|---|
| 1-min stair climbing | Stair climbing | No. of stairs climbed in 1 min | A flight of stairs with handrails, stopwatch |
| 30-s chair stand test | Rising from a chair | No. of repetitions (sitting to standing) performed in 30 s | Chair, stopwatch |
| 5-repetition sit-to-stand | Rising from a chair | Seconds to complete 5 repetitions of sitting to standing | Chair, stopwatch |
| 50-fta walk | Walking | Seconds to complete a 50-ft course at maximum speed | Measuring tape, stopwatch, markers for indicating track end points |
| 50-ft walk, preferred speed | Walking | Seconds to complete a 50-ft course at preferred speed | Measuring tape, stopwatch, markers for indicating track endpoints |
| 5-min walk | Walking | Meters walked in 5 min | Measuring tape, stopwatch, markers for indicating track end points |
| Lift test | Lifting | Ordinal scale of no. of repetitions of lifting a box with a sandbag from floor to table and back | Table, 1.35-kg box with 5-kg sandbag |
| Lift test, modified | Lifting | No. of repetitions of lifting a box from floor to table and back in 1 min | Table, 1.35-kg box with 5-kg sandbag (4 kg for women) |
| Motorized treadmill test | Walking | Total walking time and distance walked at preferred speed (nonmodifiable during the test) at the moment when walking-related symptoms make the participant stop | Treadmill, stopwatch |
| Progressive isoinertial lifting evaluation | Lifting | Weight (in kg) of the box during the last completed cycle48/no. of completed lifting cycles5,51 | Standardized box, an assortment of weights |
| Self-paced walking test | Walking | Total walking time, speed, and distance walked at the moment when walking-related symptoms make the participant stop | Distance instrument, stopwatch |
| Shuttle walking test | Walking | Meters walked until the participant fails to complete a predefined “shuttle” in the time allocated | Standardized audiotape, measuring tape, markers for indicating track end points |
| Timed “Up & Go” Test | Rising from a chair and walking | Seconds to complete rising from a chair, walking 3 m, turning around, walking back to the chair, and sitting down | Chair, stopwatch |
| Treadmill examination, 1.2 mphb | Walking | Total time walked at 1.2 mph on a treadmill at the moment when walking-related symptoms make the participant stop (time limit: 15 min) | Treadmill, stopwatch |
| Treadmill examination, preferred speed | Walking | Total time walked at preferred speed on a treadmill at the moment when walking-related symptoms make the participant stop (time limit: 15 min) | Treadmill, stopwatch |
| Treadmill protocol | Walking | Total distance, time, and average speed walked on a treadmill at preferred speed (modifiable during the test) at the moment when symptoms of lumbar spinal stenosis or other reasons make the participant stop (time limit: 30 min) | Treadmill, stopwatch |
| Treadmill walking test | Walking | Distance walked at 53.6 m/min on a treadmill at the moment when pain or fatigue makes the participant stop or when 70% of the predicted maximum heart rate (70[220 – age]/100) is reached | Treadmill, stopwatch, heart rate monitor |
| Weight-carrying test | Walking and carrying | Time needed to walk 20 m as quickly as possible while carrying dumbbells equaling 10% of the person's weight | Stopwatch, an assortment of dumbbells |
a50 ft ≈ 15.3 m.
b1.2 miles ≈ 1.9 km.
One article included patients with a pain duration of at least 6 weeks (“subacute” LBP28),37 whereas the rest included patients with a pain duration of at least 12 weeks (“chronic” LBP28). Eleven articles included patients with back-related diagnoses known to affect walking capacity severely.15,20,38–46 Of these, 1 article included patients with lumbar spondylolisthesis and postlaminectomy,38 6 articles included patients with lumbar spinal stenosis,20,39–43 3 articles included patients with lumbar disk herniation and lumbar spinal stenosis,15,44,45 and 1 article included patients with lumbar disk herniation, lumbar spinal stenosis, and spondylolisthesis.46
The included articles investigated 5 measurement properties: reliability, measurement error, construct validity (hypothesis testing), criterion validity, and responsiveness.
Quality Assessment and Data Synthesis
Reliability
The results for reliability are shown in Table 4. Regarding methodological quality, 11 articles investigated reliability.5,17,37,39,40,42,46–50 Three studies of reliability in 1 article48 were rated as poor for methodological quality and therefore excluded from the best-evidence synthesis. The poor scores were due to the fact that patients received treatment between the first and second administration of the tasks.
Table 4.
COSMIN Methodological Quality Ratings, Result Ratings, and Level of Evidence for Reliability and Measurement Error as Well as Minimal Important Change Per Physical Capacity Taska
| Physical Capacity Task | Study | Study Designb | Sample Size | Reliability | Measurement Error | MICc | ||||
|---|---|---|---|---|---|---|---|---|---|---|
| COSMIN Score32 | Result Ratings (+/?/−)30 | Best-Evidence Synthesis: Level of Evidence | COSMIN Score32 | Result Ratings (+/?/−)30 | Best-Evidence Synthesis: Level of Evidence | |||||
| 1-min stair climbing | Andersson et al51 (2010) | Test-retest | 134 | Test-retest: moderate (+) | Poord | SDC: 28.6 stepse (−) | Test-retest: moderate (−) | 14.5 steps | ||
| Smeets et al5 (2006) | Test-retest | 53 | Good | ICC(1,1): 0.96 (+) (95% CI: 0.93–0.98) | Good | LoA: ±14.7 steps (−) | ||||
| 30-s chair stand test | Kahraman et al47 (2016) | Intrarater | 38 | Goodf | ICC(2,1): 0.94 (+) (95% CI: 0.89–0.97) | Intrarater: limited (+) | No information | |||
| 5-repetition sit-to-stand | Andersson et al51 (2010) | Test-retest | 134 | Test-retest: strong (+); interrater: unknown | Poord | SDC: 11.6 se (−) | Test-retest: strong (−); interrater: unknown | −4.1 s | ||
| Simmonds et al17 (1998) | Test-retest (participants tested on different days) | 44 | Goodf | ICC(1,k): 0.89 (+) | Goodf | SDC: 6.38 se (−) | ||||
| Simmonds et al17 (1998) | Test-retest (participants tested on the same day) | 44 | Fair | ICC(1,1): 0.45 (−) | Fair | SDC: 18.46 se (−) | ||||
| Simmonds et al17 (1998) | Interrater | 22 | Fair | ICC(1,1): 0.99 (+) | SDC: 1.14 se (+) | |||||
| Smeets et al5 (2006) | Test-retest | 53 | Good | ICC(1,1): 0.91(+) (95% CI: 0.84–0.94) | Good | LoA: ±/7.6 s (−) | ||||
| Staartjes and Schroder46 (2018) | Test-retest | 66 | Fair | 0.97 (95% CI: 0.94–0.98) | SDC: 4.1 se | |||||
| Teixeira da Cunha-Filho et al50 (2010) | Test-retest | 30 | Fair | ICC(2,1): 0.99 (+) | Fair | |||||
| 50-ftb,g walk | Andersson et al51 (2010) | Test-retest | 133 | Test-retest: strong (+); interrater: unknown | Poord | SDC: 3.0 se (−) | Test-retest: strong (−); interrater: unknown | −0.7 s | ||
| Simmonds et al17 (1998) | Test-retest (participants tested on different days) | 44 | Goodf | ICC(1,1): 0.80 (+) | Goodf | SDC: 4.82 se (−) | ||||
| Simmonds et al17 (1998) | Test-retest (participants tested on the same day) | 44 | Fair | ICC(1,1): 0.99 (+) | Fair | SDC: 1.19 se (−) | ||||
| Simmonds et al17 (1998) | Interrater | 22 | Fairf | ICC(1,1): 0.99 (+) | Fairf | SDC: 0.61 s (+) | ||||
| Smeets et al5 (2006) | Test-retest | 52 | Good | ICC(1,1): 0.76 (+) (95% CI: 0.61–0.85) | Good | LoA: ±3.9 s (−) | ||||
| Strand et al48 (2011) | Test-retest | 9 | Poord | ICC(2,1): 0.77 (+) (95% CI: 0.24–0.94) | Poord | SDC: 0.6 s (+) | ||||
| Teixeira da Cunha-Filho et al50 (2010) | Test-retest | 30 | Fair | ICC(2,1): 0.96 (+) | ||||||
| 50-ft walkg, preferred walking speed | Simmonds et al17 (1998) | Test-retest (participants tested on different days) | 44 | Good | ICC(1,1): 0.64 (−) | Test-retest: conflicting; interrater: unknown | Goodf | SDC: 7.10 se (?) | Unknown | |
| Simmonds et al17 (1998) | Test-retest (participants tested on the same day) | 44 | Fair | ICC(1,1): 0.95 (+) | Fair | SDC: 2.74 se (?) | ||||
| Simmonds et al17 (1998) | Interrater | 22 | Fairf | ICC(1,1): 0.98 (+) | Fair | SDC: 1.52 se (?) | ||||
| 5-min walk | Andersson et al51 (2010) | Test-retest | 132 | Test-retest: strong (+) | Poord | SDC: 105.1 me (−) | Test-retest: moderate (−) | 21.4 m | ||
| Simmonds et al17 (1998) | Test-retest (participants tested on different days) | 44 | Goodf | ICC(1,1): 0.99 (+) | Goodf | SDC: 100.3 me (−) | ||||
| Smeets et al5 (2006) | Test-retest | 53 | Good | ICC(1,1): 0.89 (+) (95% CI: 0.81–0.93) | Good | LoA: ±82.7 m (?) | ||||
| Teixeira da Cunha-Filho et al50 (2010) | Test-retest | 30 | Fair | ICC(2,1): 0.99 (+) | ||||||
| Lift test | Magnussen37 (2004) | Interrater | 32 | Goodf | κ: 1.00 (+) (95% CI: 1.00–1.00) | Interrater, subacute LBP: limited (+); test-retest, subacute LBP: limited (−) | No information | |||
| Magnussen37 (2004) | Test-retest | 28 | Goodf | κ: 0.55 (−) (95% CI: 0.51–0.59) | ||||||
| Lift test, modified | Strand et al48 (2011) | Test-retest | 9 | Poord | ICC(2,1): 0.87 (+) (95% CI: 0.50–0.97) | Test-retest: unknown | Poord | SDC: 6.5 lifts/min (−) | Unknown | 2.5 lifts/min |
| Progressive isoinertial lifting evaluation | Andersson et al51 (2010) | Test-retest | 126 | Test-retest: moderate (+) | Poord | SDC: 4.2 stagese (−) | Test-retest: moderate (−) | 1.5 stages | ||
| Smeets et al5 (2006) | Test-retest | 50 | Good | ICC(1,1): 0.92 (+) (95% CI: 0.87–0.96) | Good | LoA: ±2 stages (?) | ||||
| Strand et al48 (2011) | Test-retest | 9 | Poord | ICC(2,1): 0.91 (+) (95% CI: 0.65–0.98) | Poord | SDC: 8.4 kg (?) | ||||
| Self-paced walking test | Tomkins et al42 (2009) | Test-retest | 33 | Fair | ICC(3,1): 0.98 (+) | Test-retest, LSS: limited (+) | No information | |||
| Shuttle walking test | Armstrong et al52 (2005) | Test-retest | Test-retest: limited (+); test-retest, LSS: limited (+) | Goodf | LoA: ±22 m (?) | Unknown | ||||
| Pratt et al40 (2002) | Test-retest | 29 | Fairf | ICC(?,?): 0.92 (+) | ||||||
| Taylor et al49 (2001) | Test-retest | 44 | Fairf | ICC(1,1): 0.99 (+) | Fair | LoA: ±49.5 m (?) | ||||
| Timed “Up & Go” Test | Gautschi et al44 (2017) | Test-retest | 18–62 | Test-retest: moderate (+); interrater: unknown; test-retest, LDH/LSS/DDD: unknown | Poord | Average SDC: 4.9 s (?) | Test-retest: unknown; test-retest, LDH/LSS/DDD: unknown | LDH/LSS/DDD: 3.4 s | ||
| Simmonds et al17 (1998) | Test-retest (participants tested on different days) | 44 | Goodf | ICC(1,k): 0.98 (+) | Goodf | SDC: 2.74 se (?) | ||||
| Simmonds et al17 (1998) | Test-retest (participants tested on the same day) | 44 | Fair | ICC(1,1): 0.98 (+) | Fair | SDC: 1.16 se (?) | ||||
| Simmonds et al17 (1998) | Interrater | 22 | Fairf | ICC(1,1): 0.99 (+) | Fairf | SDC: 0.80 se | ||||
| Teixeira da Cunha-Filho et al50 (2010) | Test-retest | 30 | Fair | ICC(2,1): 0.92 (+) | ||||||
| Treadmill examination, 1.2 mi/hh | Deen et al39 (2000) | Test-retest | 28 | Fairf | CCC: 0.90 (+) | Test-retest, LSS: limited (+) | No information | |||
| Treadmill examination, preferred speed | Deen et al39 (2000) | Test-retest | 28 | Fairf | CCC: 0.96 (+) | Test-retest, LSS: limited (+) | No information | |||
aCCC = concordance correlation coefficient (comparable to ICC67); COSMIN = Consensus-Based Standards for the Selection of Health Measurement Instruments; DDD = lumbar degenerative disk disease; ICC = intraclass correlation coefficient; LBP = low back pain; LDH = lumbar disk herniation; LoA = limits of agreement; LSS = lumbar spinal stenosis; MIC = minimal important change; SDC = smallest detectable change. + = positive rating: ICC or weighted κ ≥ 0.70 (reliability), or SDC or LoA < MIC (measurement error); ? = indeterminate rating: ICC or weighted κ not reported (reliability) or MIC not defined (measurement error); − = negative rating: criteria for “+” not met.
bIntrarater reliability = when presenting repeatedly the same observations to 1 observer; interrater reliability = when presenting the same observations to 2 or more observers; test-retest reliability = when presenting the same task to the same subjects 2 or more times.68
cThe MIC (defined as “the smallest change in score that is perceived as important by patients”23) was added for reference because this value is needed to determine the result ratings for measurement error.66
dNot included in the data synthesis because of the poor methodological score.23
eThe SDC (defined as “the smallest change that can be detected by the measurement instrument, beyond measurement error”23) was calculated23 by the authors of the present systematic review by multiplying the standard error of measurement presented in the original article by 1.96 ×
.
fThe rating changed after removal of the sample size item from the “worst score counts” summary in the COSMIN 4-point checklist.
g50 ft ≈ 15.3 m.
h1.2 miles ≈ 1.9 km.
With regard to best-evidence synthesis, a strong level of evidence for positive ratings for test-retest reliability was found for 3 tasks (50-ft [∼15.3-m] walk, 5-minute walk, and 5-repetition sit-to-stand tasks). A moderate level of evidence for positive ratings for test-retest reliability was found for 4 tasks (1-minute stair-climbing, Progressive Isoinertial Lifting Evaluation, and Timed “Up & Go” tasks). Four tasks were specifically evaluated for patients with back-related diagnoses known to severely affect walking capacity (self-paced walking test, shuttle walking test, and treadmill examination at 1.2 mph [∼1.9 km/h] and at preferred speed), and all of these had limited evidence for positive ratings for test-retest reliability. Intrarater reliability was assessed for 1 task (30-second chair stand test), which had limited evidence for a positive rating. Most of the tasks investigated for interrater reliability displayed unknown evidence due to small sample sizes.
Measurement error
The results for measurement error are shown in Table 4.
Regarding methodological quality, 8 articles investigated measurement error.5,17,44,46,48,49,51,52 Nine studies of measurement error in 3 articles44,48,51 were rated as poor and therefore excluded from the best-evidence synthesis. The poor scores were due to the fact that patients in the articles received treatment between the first and second administration of the tasks.
With regard to best-evidence synthesis, a moderate level of evidence for negative ratings for measurement error was displayed by the 1-minute stair-climbing, 5-minute walk, and Progressive Isoinertial Lifting Evaluation tasks. A strong level of evidence for negative ratings was displayed by 50-ft walk and 5-repetition sit-to-stand tasks. The negative ratings were a consequence of failure to meet the criterion stating that the smallest detectable change must be smaller than the minimal important change.30 The level of evidence was unknown for 4 tasks (50-ft walk [preferred speed] task, modified lift test, shuttle walking test, and Timed “Up & Go” task), because the minimal important change was not investigated.
Construct validity (hypothesis testing)
The results for construct validity (hypothesis testing) are shown in eTable 1 (available at https://academic.oup.com/ptj).
With regard to methodological quality, 12 articles investigated construct validity.17,19,20,41,43,44,47,48,50,53–55 Five studies of construct validity in 2 articles53,54 were rated as poor and therefore excluded from the best-evidence synthesis. The poor scores were due to an absence of a priori validity hypotheses (such as the hypothesized correlation between 2 outcome measures required for adequate validity).
With regard to best-evidence synthesis, a moderate level of evidence for positive ratings of construct validity was found for 6 tasks (50-ft walk task, 5-minute walk task, modified lift test, Progressive Isoinertial Lifting Evaluation, 5-repetition sit-to-stand task, and Timed “Up & Go” task). Limited evidence for positive ratings for construct validity was found for 4 walking tasks investigated specifically for patients with back-related diagnoses known to severely affect walking capacity (Timed “Up & Go” task, motorized treadmill test, treadmill walking test, and weight-carrying test).
Criterion validity
The results for criterion validity are shown in eTable 1.
With regard to methodological quality, 1 article investigated criterion validity42 and was rated as good for methodological quality and was therefore included in the best-evidence synthesis.
As regards best-evidence synthesis, the treadmill protocol displayed limited evidence for a positive rating for criterion validity for patients with lumbar spinal stenosis.
Responsiveness
The results for responsiveness are shown in eTable 2.
Regarding methodological quality, 7 articles investigated responsiveness.38,41,48,49,51,56,57 All studies of responsiveness in the articles received either fair or good scores and were therefore included in the best-evidence synthesis.
With regard to best-evidence synthesis, a limited level of evidence for positive ratings for responsiveness was found for 3 tasks (1-minute stair-climbing task, shuttle walking test, and 5-repetition sit-to-stand task). A moderate level of evidence for negative ratings was found for 3 tasks (50-ft walk task, modified lift test, and Progressive Isoinertial Lifting Evaluation). A limited level of evidence for negative ratings was found for 4 tasks (5-minute walk task, lift test, motorized treadmill test, and self-paced walking test). A limited level of evidence for a positive rating for responsiveness was found for 1 task (Timed “Up & Go” task) that was specifically for patients with back-related diagnoses known to severely affect walking capacity.
Summary of the level of evidence
A summary of the level of evidence is shown in Table 5.
Table 5.
Overview of the Level of Evidence Per Measurement Property Per Physical Capacity Taska
| PhysicalCapacity Task | Test-Retest Reliability | Interrater Reliability | Intrarater Reliability | Measurement Error | Hypothesis Testing | Criterion Validity | Responsiveness |
|---|---|---|---|---|---|---|---|
| 1-min stair climbing | Moderate (+) | 0 | 0 | Moderate (−) | 0 | 0 | Limited (+) |
| 30-s chair stand | 0 | 0 | Limited (+) | 0 | Limited (+) | 0 | 0 |
| 5-repetition sit-to-stand | Strong (+) | Unknown | 0 | Strong (−) | Moderate (+) | 0 | Limited (+) |
| 50-ftb walk | Strong (+) | Unknown | 0 | Strong (−) | Moderate (+) | 0 | Moderate (−) |
| 50-ft walk, preferred speed | Conflicting | Unknown | 0 | Unknown | Conflicting | 0 | 0 |
| 5-min walk | Strong (+) | 0 | 0 | Moderate (−) | Moderate (+) | 0 | Limited (−) |
| Lift test | Limited (−) | Limited (+) | 0 | 0 | 0 | 0 | Limited (−) |
| Lift test, modified | Unknown | 0 | 0 | Unknown | Moderate (+) | 0 | Moderate (−) |
| Motorized treadmill test | 0 | 0 | 0 | 0 | Limited (+)c | 0 | Limited (−)c |
| Progressive isoinertial lifting evaluation | Moderate (+) | 0 | 0 | Moderate (−) | Moderate (+) | 0 | Moderate (−) |
| Self-paced walking test | Limited (+)c | 0 | 0 | 0 | Conflictingc | 0 | Limited (−)c |
| Shuttle walking test | Limited (+), Limited (+)c | 0 | 0 | Unknown | 0 | 0 | Limited (+), Limited (+)c |
| Timed “Up & Go” Test | Moderate (+) | Unknown | 0 | Unknown | Moderate (+), Limited (+)c | 0 | Limited (+)c |
| Treadmill examination, 1.2 mphd | Limited (+)c | 0 | 0 | 0 | 0 | 0 | 0 |
| Treadmill examination, preferred speed | Limited (+)c | 0 | 0 | 0 | 0 | 0 | 0 |
| Treadmill protocol | 0 | 0 | 0 | 0 | 0 | Limited (+)c | 0 |
| Treadmill walking test | 0 | 0 | 0 | 0 | Limited (+)c | 0 | 0 |
| Weight-carrying test | 0 | 0 | 0 | 0 | Limited (+)c | 0 | 0 |
a+ = positive result rating; − = negative result rating; 0 = no information
b50 ft ≈ 15.3 m.
cThe level of evidence marked in italics primarily concerns patients with back-related diagnoses known to severely affect walking capacity (eg, lumbar spinal stenosis, spondylolisthesis).
d1.2 miles ≈ 1.9 km.
The 5-repetition sit-to-stand task was the only physical capacity task that displayed positive ratings for more than 2 measurement properties: test-retest reliability (strong evidence), construct validity (moderate evidence), and responsiveness (limited evidence). The 50-ft walk, 5-minute walk, Progressive Isoinertial Lifting Evaluation, and Timed “Up & Go” tasks displayed moderate to strong evidence for positive ratings for both test-retest reliability and construct validity. The above-mentioned tasks, however, also displayed moderate to strong evidence for negative ratings for measurement error. The 1-minute stair-climbing task and shuttle walking test displayed positive ratings for responsiveness (limited evidence) as well as for test-retest reliability (moderate evidence for 1-minute stair-climbing task and limited evidence for shuttle walking test).
Of the walking tasks that were specifically investigated for patients with diagnoses known to severely affect walking capacity, the Timed “Up & Go” task and shuttle walking test were the only tasks that displayed positive ratings for more than 1 measurement property.
Discussion
To our knowledge, this is the first study to determine the level of evidence for the reliability, validity, and responsiveness of physical capacity tasks designed to assess functioning for patients with LBP. The 5-repetition sit-to-stand, 50-ft walk, 5-minute walk, Progressive Isoinertial Lifting Evaluation, and Timed “Up & Go” tasks displayed moderate to strong evidence for positive ratings for both test-retest reliability and construct validity. These results suggest that a clinician or researcher can be confident that the scores of these tasks have a high degree of reliability and are likely to measure the constructs they are designed to measure.23 A previous systematic review investigated the reliability of physical capacity tasks, but not the validity and responsiveness.58 That review reported similar results for reliability, despite a different method for determining the level of evidence.58
The 1-minute stair climbing task, 5-repetition sit-to-stand task, shuttle walking test, and Timed “Up & Go” displayed limited evidence for positive ratings for responsiveness. These results suggest that these tasks appear to have the ability to detect changes in functioning after a treatment, although the evidence is limited. In contrast, most included tasks that were investigated for responsiveness displayed limited to moderate evidence for negative ratings. An important aspect of the definition of responsiveness in the COSMIN taxonomy is the ability to detect change over time specifically in the construct to be measured.29 However, most of the included articles investigated responsiveness by comparison with global rating scales of constructs such as “LBP-associated disability,”51 “general health improvements,”38 and “return to work,”56 all constructs that are different from those found in the physical capacity tasks. In contrast, several authors have recommended using global rating scales of the same constructs as the outcome measures of interest.23 For instance, the responsiveness of a walking task could preferably be investigated by comparing the results with a global rating scale concerning walking ability.23 Future high-quality studies with a priori hypotheses that include global rating scales of capacity could show clearer evidence for the responsiveness of physical capacity tasks.
A moderate to strong level of evidence for negative ratings for measurement error was displayed by 5 tasks because the smallest detectable change was larger than the minimal important change. Similar findings have been reported previously for PROMs of self-efficacy and health-related quality of life.59,60 The smallest detectable change (defined as “the smallest change that can be detected by the measurement instrument, beyond measurement error”23) should be smaller than the minimal important change (defined as “the smallest change in score that is perceived as important by patients”23) in order to detect changes that are as small as the minimal important change.61 The data of the systematic review suggest that the smallest detectable change of the investigated tasks appears to be too large to distinguish minimal important change from measurement error. Nevertheless, all negative ratings of measurement error were due to comparisons with minimal important change values determined for 5 tasks in a single article.51 That article investigated minimal important change values with a global rating scale of “LBP-related disability” rather than the constructs that the physical capacity tasks measure. In contrast, minimal important change is recommended to be compared with similar constructs as those in the outcome measures of interest.61 Moreover, the COSMIN 4-point scale is also not designed to assess the quality of studies that investigate minimal important change32 and therefore the methodological quality of the relevant article was undetermined.
We argue that the results of the systematic review are generalizable to most individuals with chronic LBP. Research suggests that a representative sample is required to generalize the results of measurement properties beyond the research setting.23 The patients in the systematic review comprise a heterogeneous sample, which is partly reflected in the differences in levels of pain and disability seen between the included studies (Tab. 2). Although we acknowledge that such heterogeneity can influence the results of physical capacity testing (eg, meters walked or weight lifted), there seems to be little evidence that the heterogeneity would affect the results of measurement properties. Not least, this is seen in the almost unanimous positive results for test-retest reliability and construct validity regardless of the characteristics of the study populations. A subset of the results is, however, primarily generalizable to patients with back-related diagnoses known to severely affect walking capacity such as lumbar spinal stenosis and spondylolisthesis (see the level of evidence marked in italics in Tab. 5).62–64 In the data synthesis of walking tasks, we therefore did not combine studies of such patients with other studies.
Predominantly positive ratings for single measurement properties were found for walking tasks specifically investigated for patients with back-related diagnoses known to affect walking capacity severely. However, only the Timed “Up & Go” task and shuttle walking test displayed positive ratings for more than 1 measurement property. This result appears to be due to a lack of studies investigating measurement properties with the same test protocol. For instance, 5 treadmill walking tasks with similar protocols20,41–43 were evaluated for patients with lumbar spinal stenosis, but these protocols were considered too heterogeneous for the results to be combined in the data synthesis. Physical capacity tasks investigated in future research might show a stronger level of evidence considering the promising results reported in these articles.
Strengths and Limitations
A strength of the present review was the use of the COSMIN 4-point checklist for assessing the methodological quality of the included articles.32 To our knowledge, the checklist is the most widely used consensus-based quality assessment tool specifically developed for studies on measurement properties. During the course of this systematic review, the COSMIN checklist and the data synthesis procedure were updated.65,66 For instance, poor studies are included in the new data synthesis procedure.65,66 After weighing the pros and cons we decided to proceed with the original methodology as in our PROSPERO study protocol. In summary, we reasoned that the changes in the updated COSMIN methodology would not change the quality of the analysis. Moreover, breaching the study protocol would have decreased our trustworthiness in performing the data synthesis.
Another strength is the clearly defined construct that formed the basis for the selection of articles, ie, “capacity” in the ICF activity domain.3 This approach generated more homogeneous test content, which can make the results of the systematic review easier to interpret. Capacity denotes a patient's ability to perform an activity in a standardized environment and is useful to assess and compare patients’ functioning in a standardized way.3 However, it is important to note that results from a physical capacity task are not directly transferable to a patient's environment outside the test conditions, but rather signify the patient's potential of performing the activity outside the test conditions.
This review also has a few limitations. First, the COSMIN 4-point checklist was originally developed for PROMs,32 which could compromise its validity for assessing physical capacity tasks. However, we argue that the checklist is indeed appropriate for physical capacity tasks because the items of the checklist are phrased in a general manner and draw upon the researchers’ knowledge of the test at hand, such as the appropriate time interval between the first and second administrations in a reliability study. The checklist has also been successfully used in previous systematic reviews of physical capacity tasks for other patient groups.33,35
Another possible limitation is the exclusion of so-called functional capacity evaluations because we could not obtain the original test manuals for these tests due to copyright issues. Functional capacity evaluations are test batteries commonly used for return-to-work evaluations and could potentially have added value to this systematic review. However, we could not reliably determine the quality of the tests because we could not review the detailed procedures. Also, many of the excluded functional capacity evaluation articles appeared to focus on either the composite scores of the batteries or constructs such as “level of effort,” “work capacity,” and “safe lifting,” which would have led to the exclusion of several articles.
A final possible limitation is that the data extraction was not performed completely independently, as 1 author (M.J.) extracted the data and a second author (A.G., M.L., or R.S.) double-checked it for accuracy. In contrast, at least 2 authors independently performed all other methodological steps of the review. We decided on the current data extraction procedure because of the high accuracy of the first author in the pilot of this methodological step. We therefore argue that having a second author double-checking all data extracted was almost equivalent to having 2 authors independently performing the data extraction.
Conclusion
In conclusion, the 5-repetition sit-to-stand, 5-minute walk, 50-ft walk, Progressive Isoinertial Lifting Evaluation, Timed “Up & Go,” and 1-minute stair-climbing tasks are promising physical capacity tasks for the measurement of functioning in patients with chronic LBP. However, more research on the measurement error and responsiveness of these tasks is needed to be able to fully recommend them as outcome measures in research and clinical practice for patients with LBP.
Supplementary Material
Author Contributions and Acknowledgments
Concept/idea/research design: M. Jakobsson, A. Gutke, L.B. Mokkink, R. Smeets, M. Lundberg
Writing: M. Jakobsson, A. Gutke, L.B. Mokkink, R. Smeets, M. Lundberg
Data collection: M. Jakobsson, M. Lundberg
Data analysis: M. Jakobsson, A. Gutke, L.B. Mokkink, R. Smeets, M. Lundberg
Project management: M. Jakobsson, M. Lundberg
Fund procurement: M. Lundberg
Providing facilities/equipment: M. Lundberg
Providing institutional liaisons: R. Smeets, M. Lundberg
Consultation (including review of manuscript before submitting): A. Gutke, L.B. Mokkink, R. Smeets, M. Lundberg
The authors of the systematic review would like to acknowledge the medical librarians Anders Wändahl and Klas Moberg at Karolinska Institutet University Library for their valuable help in developing the search strategy and performing the search.
Funding
This review was supported by AFA Försäkring 120216, the Eurospine Research Grants 8-2014, the Health and Medical Care Executive Board of the Västra Götaland Region, and Vetenskapsrådet 2015-02511.
Clinical Trial or Systematic Review Registration
The study protocol was registered at the International Prospective Register of Systematic Reviews (PROSPERO; http://www.crd.york.ac.uk/PROSPERO; registration number: CRD42016042011).
Disclosures
The authors completed the ICJME Form for Disclosure of Potential Conflicts of Interest. A. Gutke reported a grant received by her institution from the Swedish Research Council. No other authors reported any conflicts of interest.
References
- 1. Hoy D, March L, Brooks P et al.. The global burden of low back pain: estimates from the Global Burden of Disease 2010 study. Ann Rheum Dis. 2014;73:968–974. [DOI] [PubMed] [Google Scholar]
- 2. Breivik H, Collett B, Ventafridda V, Cohen R, Gallacher D. Survey of chronic pain in Europe: prevalence, impact on daily life, and treatment. Eur J Pain. 2006;10:287–333. [DOI] [PubMed] [Google Scholar]
- 3. World Health Organization. The International Classification of Functioning, Disability and Health (ICF). 2nd ed Geneva, Switzerland: World Health Organization; 2001. [Google Scholar]
- 4. Gautschi OP, Corniola MV, Schaller K, Smoll NR, Stienen MN. The need for an objective outcome measurement in spine surgery–the timed-up-and-go test. Spine J. 2014;14:2521–2522. [DOI] [PubMed] [Google Scholar]
- 5. Smeets RJ, Hijdra HJ, Kester AD, Hitters MW, Knottnerus JA. The usability of six physical performance tasks in a rehabilitation population with chronic low back pain. Clin Rehabil. 2006;20:989–998. [DOI] [PubMed] [Google Scholar]
- 6. Wittink H. Functional capacity testing in patients with chronic pain. Clin J Pain. 2005;21:197–199. [DOI] [PubMed] [Google Scholar]
- 7. Daltroy LH, Cats-Baril WL, Katz JN, Fossel AH, Liang MH. The North American spine society lumbar spine outcome assessment instrument: reliability and validity tests. Spine (Phila Pa 1976). 1996;21:741–749. [DOI] [PubMed] [Google Scholar]
- 8. Fairbank JC, Pynsent PB. The Oswestry Disability Index. Spine. 2000;25:2940–2952. [DOI] [PubMed] [Google Scholar]
- 9. Salen BA, Spangfort EV, Nygren AL, Nordemar R. The Disability Rating Index: an instrument for the assessment of disability in clinical settings. J Clin Epidemiol. 1994;47:1423–1435. [DOI] [PubMed] [Google Scholar]
- 10. Kopec JA, Esdaile JM, Abrahamowicz M et al.. The Quebec Back Pain Disability Scale: conceptualization and development. J Clin Epidemiol. 1996;49:151–161. [DOI] [PubMed] [Google Scholar]
- 11. Roland M, Morris R. A study of the natural history of back pain. Part I: development of a reliable and sensitive measure of disability in low-back pain. Spine (Phila Pa 1976). 1983;8:141–144. [DOI] [PubMed] [Google Scholar]
- 12. Food and Drug Administration Center for Drug Evaluation and Research. Guidance for Industry. Patient-Reported Outcome Measures: Use in Medical Product Development to Support Labeling Claims. Silver Spring, MD: Food and Drug Administration; 2009. [Google Scholar]
- 13. Brodke DS, Goz V, Lawrence BD, Spiker WR, Neese A, Hung M. Oswestry Disability Index: a psychometric analysis with 1,610 patients. Spine J. 2017;17:321–327. [DOI] [PubMed] [Google Scholar]
- 14. Chiarotto A, Ostelo RW, Boers M, Terwee CB. A systematic review highlights the need to investigate the content validity of patient-reported outcome measures for physical functioning in patients with low back pain. J Clin Epidemiol. 2018;95:73–93. [DOI] [PubMed] [Google Scholar]
- 15. Gautschi OP, Smoll NR, Corniola MV et al.. Validity and reliability of a measurement of objective functional impairment in lumbar degenerative disc disease: the Timed Up and Go (TUG) test. Neurosurgery. 2016;79:270–278. [DOI] [PubMed] [Google Scholar]
- 16. Caporaso F, Pulkovski N, Sprott H, Mannion AF. How well do observed functional limitations explain the variance in Roland Morris scores in patients with chronic non-specific low back pain undergoing physiotherapy?. Eur Spine J. 2012;21:187–195. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 17. Simmonds MJ, Olson SL, Jones S et al.. Psychometric characteristics and clinical usefulness of physical performance tests in patients with low back pain. Spine. 1998;23:2412–2421. [DOI] [PubMed] [Google Scholar]
- 18. Harding VR, Williams AC, Richardson PH et al.. The development of a battery of measures for assessing physical functioning of chronic pain patients. Pain. 1994;58:367–375. [DOI] [PubMed] [Google Scholar]
- 19. Lee CE, Simmonds MJ, Novy DM, Jones S. Self-reports and clinician-measured physical function among patients with low back pain: a comparison. Arch Phys Med Rehabil. 2001;82:227–231. [DOI] [PubMed] [Google Scholar]
- 20. Conway J, Tomkins CC, Haig AJ. Walking assessment in people with lumbar spinal stenosis: capacity, performance, and self-report measures. Spine J. 2011;11:816–823. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 21. Guralnik JM, Branch LG, Cummings SR, Curb JD. Physical performance measures in aging research. J Gerontol. 1989;44:M141–M146. [DOI] [PubMed] [Google Scholar]
- 22. Wand BM, Chiffelle LA, O'Connell NE, McAuley JH, Desouza LH. Self-reported assessment of disability and performance-based assessment of disability are influenced by different patient characteristics in acute low back pain. Eur Spine J. 2010;19:633–640. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 23. de Vet HCW, Terwee CB, Mokkink LB, Knol DL. Measurement in Medicine: A Practical Guide. Cambridge, England: Cambridge University Press; 2011. [Google Scholar]
- 24. Brakenhoff TB, Mitroiu M, Keogh RH, Moons KGM, Groenwold RHH, van Smeden M. Measurement error is often neglected in medical literature: a systematic review. J Clin Epidemiol. 2018;98:89–97. [DOI] [PubMed] [Google Scholar]
- 25. Brakenhoff TB, van Smeden M, Visseren FLJ, Groenwold RHH. Random measurement error: why worry? An example of cardiovascular risk factors. PLoS One. 2018;13:e0192298. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 26. Moher D, Liberati A, Tetzlaff J, Altman DG. Preferred reporting items for systematic reviews and meta-analyses: the PRISMA statement. PLoS Med. 2009;6:e1000097. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 27. Terwee CB, Jansma EP, Riphagen II, de Vet HCW. Development of a methodological PubMed search filter for finding studies on measurement properties of measurement instruments. Qual Life Res. 2009;18:1115–1123. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 28. van Tulder M, Becker A, Bekkering T et al.. Chapter 3. European guidelines for the management of acute nonspecific low back pain in primary care. Eur Spine J. 2006;15:S169–S191. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 29. Mokkink LB, Terwee CB, Patrick DL et al.. The COSMIN study reached international consensus on taxonomy, terminology, and definitions of measurement properties for health-related patient-reported outcomes. J Clin Epidemiol. 2010;63:737–745. [DOI] [PubMed] [Google Scholar]
- 30. Prinsen CAC, Vohra S, Rose MR et al.. How to select outcome measurement instruments for outcomes included in a “Core Outcome Set”—a practical guideline. Trials. 2016;17:449. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 31. Mokkink L, Terwee C, Patrick D et al.. The COSMIN checklist for assessing the methodological quality of studies on measurement properties of health status measurement instruments: an international Delphi study. Qual Life Res. 2010;19:539–549. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 32. Terwee C, Mokkink L, Knol D, Ostelo RJG, Bouter L, de Vet HW. Rating the methodological quality in systematic reviews of studies on measurement properties: a scoring system for the COSMIN checklist. Qual Life Res. 2012;21:651–657. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 33. Dobson F, Hinman RS, Hall M, Terwee CB, Roos EM, Bennell KL. Measurement properties of performance-based measures to assess physical function in hip and knee osteoarthritis: a systematic review. Osteoarthritis Cartilage. 2012;20:1548–1562. [DOI] [PubMed] [Google Scholar]
- 34. Mokkink LB, Terwee CB, Gibbons E et al.. Inter-rater agreement and reliability of the COSMIN (COnsensus-based Standards for the selection of health status Measurement Instruments) checklist. BMC Med Res Methodol. 2010;10:82. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 35. Kroman SL, Roos EM, Bennell KL, Hinman RS, Dobson F. Measurement properties of performance-based outcome measures to assess physical function in young and middle-aged people known to be at high risk of hip and/or knee osteoarthritis: a systematic review. Osteoarthritis Cartilage. 2014;22:26–39. [DOI] [PubMed] [Google Scholar]
- 36. Guyatt GH, Oxman AD, Vist GE et al.. GRADE: an emerging consensus on rating quality of evidence and strength of recommendations. BMJ. 2008;336:924–926. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 37. Magnussen L, Strand LI, Lygren H. Reliability and validity of the back performance scale: observing activity limitation in patients with back pain. Spine (Phila Pa 1976). 2004;29:903–907. [DOI] [PubMed] [Google Scholar]
- 38. Campbell H, Rivero-Arias O, Johnston K, Gray A, Fairbank J, Frost H. Responsiveness of objective, disease-specific, and generic outcome measures in patients with chronic low back pain: an assessment for improving, stable, and deteriorating patients. Spine (Phila Pa 1976). 2006;31:815–822. [DOI] [PubMed] [Google Scholar]
- 39. Deen HG Jr, Zimmerman RS, Lyons MK, McPhee MC, Verheijde JL, Lemens SM. Test-retest reproducibility of the exercise treadmill examination in lumbar spinal stenosis. Mayo Clin Proc. 2000;75:1002–1007. [DOI] [PubMed] [Google Scholar]
- 40. Pratt RK, Fairbank JC, Virr A. The reliability of the Shuttle Walking Test, the Swiss Spinal Stenosis Questionnaire, the Oxford Spinal Stenosis Score, and the Oswestry Disability Index in the assessment of patients with lumbar spinal stenosis. Spine (Phila Pa 1976). 2002;27:84–91. [DOI] [PubMed] [Google Scholar]
- 41. Rainville J, Childs LA, Pena EB et al.. Quantification of walking ability in subjects with neurogenic claudication from lumbar spinal stenosis–a comparative study. Spine J. 2012;12:101–109. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 42. Tomkins CC, Battie MC, Rogers T, Jiang H, Petersen S. A criterion measure of walking capacity in lumbar spinal stenosis and its comparison with a treadmill protocol. Spine (Phila Pa 1976). 2009;34:2444–2449. [DOI] [PubMed] [Google Scholar]
- 43. Whitehurst M, Brown LE, Eidelson SG, D'Angelo A. Functional mobility performance in an elderly population with lumbar spinal stenosis. Arch Phys Med Rehabil. 2001;82:464–467. [DOI] [PubMed] [Google Scholar]
- 44. Gautschi OP, Stienen MN, Corniola MV et al.. Assessment of the minimum clinically important difference in the Timed Up and Go test after surgery for lumbar degenerative disc disease. Neurosurgery. 2017;80:380–385. [DOI] [PubMed] [Google Scholar]
- 45. Gautschi OP, Joswig H, Corniola MV et al.. Pre- and postoperative correlation of patient-reported outcome measures with standardized Timed Up and Go (TUG) test results in lumbar degenerative disc disease. Acta Neurochir (Wien). 2016;158:1875–1881. [DOI] [PubMed] [Google Scholar]
- 46. Staartjes VE, Schroder ML. The five-repetition sit-to-stand test: evaluation of a simple and objective tool for the assessment of degenerative pathologies of the lumbar spine. J Neurosurg Spine. 2018;29:380–387. [DOI] [PubMed] [Google Scholar]
- 47. Kahraman T, Ozcan Kahraman B, Salik Sengul Y, Kalemci O. Assessment of sit-to-stand movement in nonspecific low back pain: a comparison study for psychometric properties of field-based and laboratory-based methods. Int J Rehabil Res. 2016;39:165–170. [DOI] [PubMed] [Google Scholar]
- 48. Strand LI, Anderson B, Lygren H, Skouen JS, Ostelo R, Magnussen LH. Responsiveness to change of 10 physical tests used for patients with back pain. Phys Ther. 2011;91:404–415. [DOI] [PubMed] [Google Scholar]
- 49. Taylor S, Frost H, Taylor A, Barker K. Reliability and responsiveness of the shuttle walking test in patients with chronic low back pain. Physiother Res Int. 2001;6:170–178. [DOI] [PubMed] [Google Scholar]
- 50. Teixeira da Cunha-Filho I, Lima FC, Guimarães FR, Leite HR. Use of physical performance tests in a group of Brazilian Portuguese-speaking individuals with low back pain. Physiother Theory Pract. 2010;26:49–55. [DOI] [PubMed] [Google Scholar]
- 51. Andersson EI, Lin CC, Smeets RJ. Performance tests in people with chronic low back pain: responsiveness and minimal clinically important change. Spine (Phila Pa 1976). 2010;35:E1559–E1563. [DOI] [PubMed] [Google Scholar]
- 52. Armstrong M, McDonough S, Baxter D. Reliability and repeatability of the shuttle walk test in patients with chronic low back pain. Int J Ther Rehabil. 2005;12:438–443. [Google Scholar]
- 53. Ocarino J, Gonçalves G, Vaz D, Cabral A, Porto J, Silva M. Correlation between a functional performance questionnaire and physical performance tests among patients with low back pain. Braz J Phys Ther. 2009;13:343–349. [Google Scholar]
- 54. Odebiyi DO, Kujero SO, Lawal TA. Relationship between spinal mobility, physical performance, pain intensity and functional disability in patients with chronic low back pain. Nigerian Journal of Medical Rehabilitation. 2007;11:49–54. [Google Scholar]
- 55. Soer R, Poels BJ, Geertzen JH, Reneman MF. A comparison of two lifting assessment approaches in patients with chronic low back pain. J Occup Rehabil. 2006;16:639–646. [DOI] [PubMed] [Google Scholar]
- 56. Strand LI, Moe-Nilssen R, Ljunggren AE. Back Performance Scale for the assessment of mobility-related activities in people with back pain. Phys Ther. 2002;82:1213–1223. [PubMed] [Google Scholar]
- 57. Gautschi OP, Joswig H, Corniola MV et al.. Pre- and postoperative correlation of patient-reported outcome measures with standardized Timed Up and Go (TUG) test results in lumbar degenerative disc disease. Acta Neurochir (Wien). 2016;158:1875–1881. [DOI] [PubMed] [Google Scholar]
- 58. Denteneer L, Van Daele U, Truijen S, De Hertogh W, Meirte J, Stassijns G. Reliability of physical functioning tests in patients with low back pain: a systematic review. Spine J. 2018;18:190–207. [DOI] [PubMed] [Google Scholar]
- 59. Maughan EF, Lewis JS. Outcome measures in chronic low back pain. Eur Spine J. 2010;19:1484–1494. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 60. van der Roer N, Ostelo RW, Bekkering GE, van Tulder MW, de Vet HC. Minimal clinically important change for pain intensity, functional status, and general health status in patients with nonspecific low back pain. Spine (Phila Pa 1976). 2006;31:578–582. [DOI] [PubMed] [Google Scholar]
- 61. de Vet HC, Terwee CB, Ostelo RW, Beckerman H, Knol DL, Bouter LM. Minimal changes in health status questionnaires: distinction between minimally detectable change and minimally important change. Health Qual Life Outcomes. 2006;4:54. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 62. Budithi S, Dhawan R, Cattell A, Balain B, Jaffray D. Only walking matters—assessment following lumbar stenosis decompression. Eur Spine J. 2017;26:481–487. [DOI] [PubMed] [Google Scholar]
- 63. Tomkins-Lane CC, Battie MC. Predictors of objectively measured walking capacity in people with degenerative lumbar spinal stenosis. J Back Musculoskelet Rehabil. 2013;26:345–352. [DOI] [PubMed] [Google Scholar]
- 64. Drury T, Ames SE, Costi K, Beynnon B, Hall J. Degenerative spondylolisthesis in patients with neurogenic claudication effects functional performance and self-reported quality of life. Spine (Phila Pa 1976). 2009;34:2812–2817. [DOI] [PubMed] [Google Scholar]
- 65. Mokkink LB, de Vet HCW, Prinsen CAC et al.. COSMIN Risk of Bias checklist for systematic reviews of Patient-Reported Outcome Measures. Qual Life Res. 2018;27:1171–1179. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 66. Prinsen CAC, Mokkink LB, Bouter LM et al.. COSMIN guideline for systematic reviews of patient-reported outcome measures. Qual Life Res. 2018;27:1147–1157. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 67. Lin LI. A concordance correlation coefficient to evaluate reproducibility. Biometrics. 1989;45:255–268. [PubMed] [Google Scholar]
- 68. Rousson V, Gasser T, Seifert B. Assessing intrarater, interrater and test-retest reliability of continuous measurements. Stat Med. 2002;21:3431–3446. [DOI] [PubMed] [Google Scholar]
Associated Data
This section collects any data citations, data availability statements, or supplementary materials included in this article.