Abstract
Retinal imaging has undergone a revolution in the past 50 years to allow for better understanding of the eye in health and disease. Significant improvements have occurred both in hardware such as lasers and optics in addition to software image analysis. Optical imaging modalities include optical coherence tomography (OCT), OCT angiography (OCTA), photoacoustic microscopy (PAM), scanning laser ophthalmoscopy (SLO), adaptive optics (AO), fundus autofluorescence (FAF), and molecular imaging (MI). These imaging modalities have enabled improved visualization of retinal pathophysiology and have had a substantial impact on basic and translational medical research. These improvements in technology have translated into early disease detection, more accurate diagnosis, and improved management of numerous chorioretinal diseases. This article summarizes recent advances and applications of retinal optical imaging techniques, discusses current clinical challenges, and predicts future directions in retinal optical imaging.
Keywords: optical imaging, retina, optical coherence tomography (OCT), optical coherence tomography angiography (OCTA), photoacoustic microscopy, fundus autofluorescence, adaptive optics (AO), scanning laser ophthalmoscopy (SLO), molecular imaging, age-related macular degeneration (AMD), diabetic retinopathy (DR), retinal vein occlusions (RVO), choroidal neovascularization (CNV)
1. Introduction
The human eye is optically transparent, and thus the retina and choroid are ideally suited for optical imaging of pathological disease changes. By the end of the 19th century, the first photograph of the human retina had been obtained [1]. Since then, there have been huge advances in ophthalmic imaging, including fluorescein angiography (FA) and indocyanine green angiography (ICGA) and more recently scanning laser ophthalmoscopy (SLO) and optical coherence tomography (OCT). The development of these optical instruments has greatly extended our ability to evaluate chorioretinal disease pathophysiology. Furthermore, OCT angiography (OCTA) as a noninvasive angiographic technique provides visualization of vascular structures. Other appealing technologies such as adaptive optics (AO), ultra-wide field imaging, fundus autofluorescence (FAF), and photoacoustic microscopy (PAM) have been integrated into available retinal imaging modalities, which can significantly improve our image quality or field of view. Molecular imaging (MI) is an area that combines retinal molecular biomarkers and advanced ocular imaging technologies and has the potential to visualize the earliest cellular and biochemical process before advanced retinal disease. This review focuses on emerging imaging instruments, their recent advances, and medical applications.
2. Optical Coherence Tomography (OCT)
Optical coherence tomography (OCT) was first introduced for ophthalmic imaging in 1991 [2], and OCT has been rapidly and widely adopted in ophthalmology [3]. As the eye is optically accessible for visible and near-infrared light, ophthalmic OCT allows an unparalleled combination of high axial resolution (1–10 μm) with appropriate tissue penetration depth (1–2 mm in tissue) [4]. Fourier-domain OCT (FD-OCT) can be characterized into two types: spectral-domain OCT (SD-OCT) and swept source OCT (SS-OCT). With the development of time-domain OCT (TD-OCT) and the more recent FD-OCT, high quality images of the retinal structure are now clearly demonstrated, such as inner limiting membrane (ILM), retinal nerve fiber layer (RNFL), photoreceptor inner and outer segments (IS/OS), and outer limiting membrane [5]. Even though SD-OCT and SS-OCT both use the Fourier transform, SD-OCT instruments use a broadband near infrared superluminescent diode as a light source with a spectrometer as the detector. Current clinical systems often employ a center wavelength of about 840 nm (e.g., Carl Zeiss Meditec, Inc., Jena, Germany). SS-OCT instruments use a tunable swept laser, with a single photodiode detector. Current clinical systems often employ a longer center wavelength of about 1050 nm [6,7]. TD-OCT technology has limited speed and sensitivity compared with more recent SD-OCT and SS-OCT. SD-OCT has greatly improved speed and sensitivity and is able to detect small changes in morphology of retinal layers and choroidal neovascularization (CNV) activity. However, SD-OCT has difficulty differentiating vascular and fibrous components of CNV because of their similar reflectivity properties [8,9].
SS-OCT technology is the latest development in OCT technology. SS-OCT often utilizes infrared (1050 nm) laser source, has less susceptibility to sensitivity roll-off, and has ultrahigh speed image acquisition often of 100,000 Hz A scans speed or higher for clinical systems and above 1 MHz in research systems [10–14]. These characteristics of SS-OCT enable deeper penetration, excellent axial resolution, and fewer motion artifacts, to generate ultrahigh-definition B-scan images of the retinal microstructure [9]. For example, in patients with classic choroidal neovascularization (CNV), SS-OCT images in line scan mode can show intraretinal edema, CNV lesions, outer retina disorganization, RPE atrophy, and choroid and choriocapillaris thickness. SS-OCT en face mode provides a coronal view of the posterior segment of different depths and enables visualization of structures that cannot be easily appreciated in cross-sectional images [15]. When B-scan and en face mode are used together, they may provide additional anatomic insight into diseases in a non-invasive manner. The Topcon DRI Triton and the Zeiss Plex Elite 9000 are two clinical systems based on SS-OCT technology. They also provide 3D volumetric cubes that can be viewed either in cross-sectional or en face views [16–18]. Ferrara et al. [15] have described en face SS-OCT findings in patients with chronic central serous chorioretinopathy (CSCR) and neovascular age-related macular degeneration (AMD) and have reported two distinct patterns of choroidal vascular dilatation: focal and diffuse. Dansingani et al. [17] used en face SS-OCT to correlate clinical manifestations with choroidal morphology in pachychoroid disorders, including central serous chorioretinopathy, pachychoroid pigment epitheliopathy, pachychoroid neovasculopathy, and polypoidal choroidal vasculopathy. They find that en face SS-OCT can localize the changes of increased thickness and dilated outer choroidal vessels at disease foci. Dastiridou et al. [19] uses a SS-OCT device (DRI-OCT1 Atlantis; Topcon) to characterize choroidal thickness and choroidal reflectivity in the eyes of patients with birdshot chorioretinopathy. They found that there are evident changes in choroidal reflectivity and choroidal thickness between active and inactive birdshot chorioretinopathy patients. A study by Lee et al. [20] investigated total retinal blood flow(TRBF) in diabetic eyes with or without diabetic retinopathy (DR) and in healthy eyes using the high-speed en face Doppler OCT. They demonstrate that diabetic eyes with DME exhibited lower TRBF than healthy eyes. En face Doppler OCT provides an effective method for measuring TRBF in the clinic.
3. OCT Angiography (OCTA)
OCT angiography (OCTA) is a new, noninvasive imaging technique based on OCT imaging which allows for the visualization of the retinal and choroidal microvasculature without the injection of exogenous dyes [3,21–25]. OCTA is a method of visualizing vasculature that is enhanced from the signal (intensity and/or phase) change caused by erythrocyte movement that arises from multiple B-scans performed at the same position. OCTA images are essentially motion-contrast images.
Various algorithms have been developed for OCTA devices. OCTA can be separated into three categories: phase-signal-based OCTA (e.g., Doppler OCT, phase-variance OCT), intensity-signal-based OCTA (e.g., speckle-variance OCT, correlation mapping OCT, OCTA ratio analysis and split-spectrum amplitude decorrelation angiography), and complex-signal-based OCTA (e.g., optical microangiography, multiple signal classification OMAG, and imaginary part-based correlation mapping OCT) [26]. Direct comparisons among OCTA algorithms are currently limited [27,28]. In 2012, Jia et al. [29] proposed the split-spectrum amplitude decorrelation angiography (SSADA) algorithm, as a kind of intensity-signal-based OCTA method, based on the decorrelation of OCT signal amplitude due to flow. It has been demonstrated that the SSADA algorithm improves the signal to noise ratio of flow direction and facilitates visualization of retinal vasculature [8,29]. OCTA ratio analysis (OCTARA) is the intensity ratio calculation OCTA algorithm. As the full spectrum is preserved, there is no loss of axial resolution [27,30]. Optical Microangiography (OMAG) algorithm [31–35] is a complex-signal-based OCTA technique, proposed first by Wang et al. [34] in 2007. It utilizes both the intensity and phase information of the OCT signal in the flow signal calculation to increase its sensitivity. OMAG can provide angiography either with or without directional information. Optical microangiography has been used to illustrate the microcirculation in human retina. In the United States, two commercially available OCTA systems currently approved by the Food and Drug Administration (FDA) use different algorithms. The AngioVue system (Optovue, Inc., Fremont, CA, USA) [36] uses the SSADA algorithm, while the Zeiss AngioPlex system (Carl Zeiss Meditec Inc., Dublin, CA, USA) [37] employs the OMAG algorithm.
Clinical investigations that use OCTA have increased exponentially in recent years. OCTA has often replaced fluorescein angiography and become an important imaging method to evaluate retinal vascular diseases, including diabetic retinopathy (DR), retinal vein occlusions (RVO), and neovascular AMD (Figure 1) [38–41]. One common retinal vascular disease utilizing OCTA is to assess the microvascular pathology in DR [41–43]. OCTA can clearly visualize and quantify nonperfusion, neovascularization, and the foveal avascular zone (FAZ) area change, which can be helpful to identify non-proliferative DR and macular ischemia in patients with DR [44–46]. Hirano et al. [47] reported that SS-OCTA with extended field imaging (EFI) allows acquisition of large areas of en face images of retinal vasculature in patients with DR that are larger by an average ratio of 1.80 ± 0.18 (range, 1.50–2.18). OCTA is a noninvasive, rapid, and reliable method to evaluate the area of capillary nonperfusion and FAZ morphology in patients with RVO [48,49]. In addition, OCTA provides depth-resolved information that has never before been available with conventional fluorescein angiography. OCTA thus allows visualization of occult type 1 neovascular membranes in AMD, which are located under the RPE, and the microvascular details of which are not easily identified with conventional angiography [50]. Roisman et al. [51] demonstrated that SS-OMAG OCTA can identify type 1 neovascularization within ICGA plaques. One advantage of SS-OMAG OCTA over ICGA is that it can be easily repeated at follow-up visits because it is fast, safe, and noninvasive. OCTA can play an important role in treatment monitoring of intravitreal injections of anti-VEGF agents that are highly successful and currently the treatment of choice for neovascular AMD [52]. OCTA offers noninvasive monitoring of the retinal and choriocapillaris microvasculature in patients with CNV and can aid in treatment decisions during patient follow-up [53].
Fluorescein angiography (FA) is a vitally important diagnostic tool and has been the gold standard for the evaluation of patients with retinal disease since its advent in 1961 [54]. However, FA is an invasive test and requires typically 10–15 min to obtain images. FA also does not provide depth information and has difficulty imaging the deep capillary network well. OCTA, in comparison, is a non-invasive technique and has the capability to image all layers of the vasculature. However, it requires blood flow and lacks the ability to identify staining, leakage, and pooling [23,55]. OCTA technology also has other limitations. First, currently available clinical OCTA systems can have relatively poor axial resolution (~15 μm) due to signal averaging, limiting the identification of small-caliber vessels. Second, because OCTA uses the principle that movement in the back of the eye represents blood flow, it is prone to motion artifact. Although the presence of computer algorithms and eye tracking software are employed to help reduce motion artifacts, correction of all artifacts is challenging. In addition, OCTA creates flow images by comparing the differences between consecutive OCT B-scan images. OCTA may miss areas of slow blood flow such as in microaneurysms or fibrotic CNV, which give us very important information about diseases [27,55]. Future advances may reduce artifacts, and faster scanning speeds may help obtain larger fields of view. An efficient angiography algorithm with fast scanning speeds without sacrificing the posterior pole information would be a great boon to assessing the retinal vasculature non-invasively.
In conclusion, OCTA is a rapidly evolving, noninvasive, and dyeless technology that will potentially improve patient care by decreasing the disease morbidity through earlier disease detection and intervention.
4. Photoacoustic Microscopy (PAM)
Photoacoustic microscopy (PAM) is based on optical excitation and ultrasonic detection. A short pulse duration laser (nanosecond pulse duration) illuminates and excites a target tissue, thus inducing ultrasonic pressure waves because of specific optical absorption. The ultrasound transducer is focused on the tissue surface and records ultrasonic signals, generating an image [56–60].
Several groups have developed ocular PAM imaging systems [61–63]. As the technology has advanced, PAM can image retinal vasculature and the RPE with a better contrast-to-background ratio than any other intrinsic retinal imaging modality. One can obtain more quantitative imaging information, including estimation of oxygen saturation of hemoglobin (sO2) and retinal metabolic rate of oxygen (rMRO2) [64]. Hennen et al. [65] through PAM sO2 measurement concluded that PAM can resolve anatomic structures of the eye. PAM also provides a safe, non-invasive method of in vivo imaging of sO2, which is important to evaluate the role of oxidative damage, hypoxia, and ischemia in the pathogenesis of ocular diseases. Song et al. [66] combined PAM with SD-OCT to measure rMRO2 by having PAM measure the sO2 and SD-OCT map the blood flow rate. The quantitative method helps further understanding of some ocular diseases, including DR, RVO, and glaucoma.
Multimodal imaging can be very beneficial for investigating ocular pathology and detecting disease. When PAM is integrated with other imaging modalities, such as OCT, fundus photography, ultrasound imaging, fluorescence imaging, confocal scanning laser ophthalmoscopy (cSLO), and multi-photon microscopy, more structural and functional information can be acquired [66–69]. The most useful integrated imaging system utilizes both multi-wavelength PAM and OCT. Tian et al. [68] reported a novel integrated PAM and SD-OCT to image the choroid, retina, and microvasculature in living rabbits (Figure 2). In this multimodal platform, OCT can provide structural information about the retina, and PAM can reveal functional and molecular details of biological tissue particularly when combined with nanoparticle contrast agents. Another multimodal imaging example is integrating PAM, SD-OCT, and autofluorescence-scanning laser ophthalmoscopy (AF-SLO) to visualize retinal vasculature and provide the concentration of melanin in the retinal pigment epithelium [70]. At present, PAM remains at an early stage in the development process. No clinically approved system exists for eyes, and all the photoacoustic imaging work in eyes has been performed in animals or in vitro. However, its development may greatly extend the scope of retinal imaging in future.
5. Adaptive Optics (AO) and Scanning Laser Ophthalmoscopy (SLO)
AO is an emerging discipline that seeks to improve the performance of an optical system by reducing the effects of wavefront distortions [71]. AO imaging systems use active optical elements to compensate for aberrations in the optical path between the object and the camera. AO systems have three principal components: a wavefront sensor, a corrective element, and a control system [72]. The power of AO is to provide cellular level resolution imaging of retinal cells by correcting for ocular aberrations. In recent years AO has been successfully integrated with some primary ophthalmic imaging devices, including AO-SLO, fluorescence AO-SLO, AO-OCT, and AO-two photon imaging. Each integration offers unique benefits [71].
Scanning laser ophthalmoscopy (SLO) was first described in 1981 [73]. Scanning laser ophthalmoscopy (SLO) uses a single, monochromatic laser with low power and a confocal raster scanning technique to collect an image of the retina and optic nerve head [58,73]. SLO images demonstrate higher contrast than standard fundus camera photos as they can reduce the effect of light scatter. SLO has been significantly improved through integration to AO, called AO-SLO [74]. AO-SLO systems have been reported to have the capability of observing individual cone and rod photoreceptors [75], blood vessels [76], capillaries [77,78], and RPE [79,80] Many of these same structures have also been visualized with AO-OCT imaging systems. 3D visualization of the retinal nerve fiber layer, microstructure in the ganglion cell layer [81] and Henle’s fiber layer, retinal microvasculature such as choriocapillaris and the capillaries that form the rim of the foveal avascular zone (FAZ), the 3D photoreceptor mosaic, the RPE, and the tiny pores of the lamina cribrosa of the optical nerve have been demonstrated using AO-OCT [72]. Both AO-SLO and AO-OCT are promising techniques (Figure 3). They are playing an important role in observing microstructures in living human retina with growing popularity. AO-OCT in particular offers some technical advantages over AO-SLO, including improved axial resolution and increased sensitivity to weak reflections [82].
Currently, imaging methods using AO are being applied to study several diseases including macular telangiectasia, cone-rod dystrophy, retinitis pigmentosa, and AMD. The ability of an AO ophthalmoscope to resolve cells and return to the same cells in the future offers the ability to track disease progression and monitor novel treatment strategies on an unprecedented cellular scale [83].
Traditional fundus cameras take images of the retina with a 20- to 50-degree field of view. However, with conventional fundus images, a significant portion of the fundus remains unphotographed. Image montages were thus created to put together several photos and create a wider image of the retina. To extend the field of view, newer devices have sought to image more of the retinal surface, termed ultra-wide field imaging, and can provide up to a 200° view of the retina (Figure 4). This field of view is equivalent to 82% of the retinal surface compared to 15% offered by a single 45° image [84,85].
Current studies with ultra-wide field imaging modality have suggested important clinical applications for various retinal diseases, including DR, RVO, ophthalmic oncology, pediatric vitreoretinal disorders, and hereditary retinal degenerations. There is a growing consensus that ultra-wide field imaging improves detection of peripheral lesions in diabetic retinopathy, leads to more accurate classification of the disease, and gives important prognostic information on the diabetic retinopathy progression over time [85,86]. There is improvement in DR classification by using ultra-wide field imaging (Figure 4). Kumar et al. [87] described the use of ultra-wide field imaging in the diagnosis and management of adult onset Coats’ disease. They found that the ultra-wide field pseudo-color photographs and fluorescein angiograms were able to provide clinically useful information over and above that provided by conventional imaging. Ultra-wide field imaging has also been employed in other retinal imaging instruments, such as fluorescein angiography [88,89], OCT [90], SLO [91], and FAF [92].
6. Fundus Autofluorescence (FAF)
Fundus autofluorescence (FAF) imaging is a noninvasive imaging modality for in vivo mapping of naturally or pathologically occurring fluorophores of the ocular fundus. The primary sources are lipofuscin (LF) granules that have accumulated in retinal pigment epithelium (RPE) cells [94]. Excessive accumulation of lipofuscin granules in the RPE cells represents a common downstream pathogenic pathway in numerous retinal diseases [95]. The relevance of alterations in FAF images can further be addressed by assessing corresponding retinal sensitivity and response to stimuli. Severe damage to the RPE corresponds to areas of decreased autofluorescence.
The clinical applications of FAF continue to expand. It is an essential tool for evaluating AMD [96], geographic atrophy (GA), macular dystrophies, retinitis pigmentosa [97], white dot syndromes [98], and numerous other retinal disorders [99]. FAF imaging is particularly helpful for the differential diagnosis, detection, and extent delineation of involved retinal areas, genotype-phenotype correlation, and monitoring of changes overtime. FAF provides information on the metabolic state and overall health of the RPE and photoreceptors.
Quantitative AF (qAF) has potential applications in the diagnosis and monitoring of retinal conditions and may also have utility in prognosis and risk stratification. However, there is no universally accepted standard approach for qAF. This lack of standardized quantitative assessment can limit the utility of FAF as a method for diagnosis or monitoring and poses an important clinical need for future development.
7. Molecular Imaging
Conventional ophthalmic imaging platforms, such as fundus photography, scanning laser ophthalmoscopy, FA, ICGA, OCT, OCTA, and adaptive optics, are capable of imaging retinal anatomy and morphology with improved resolution. However, an important clinical challenge remains to visualize the early cellular and biochemical processes, which occur before advanced anatomic retinal changes. The aim of molecular imaging techniques is the visualization of molecular processes and functional changes in living animals and human patients before morphological changes occur at the cellular and tissue level [100]. Molecular imaging requires high image resolution, sensitive instrument detection, specific imaging agents, and endogenous molecular probes or exogenous contrast agents that link the imaging signal with a molecular probe or event [101,102].
Molecular imaging modalities include optical imaging techniques such as fluorescence and bioluminescence imaging, reflectance-based approach (e.g., SLO, retinal multispectral imaging, OCT), PAM, magnetic resonance imaging (MRI), radionuclide techniques such as positron emission tomography (PET) and single photon emission computed tomography (SPECT), ultrasonography, and computed tomography (CT) [100]. Several molecular imaging instruments are available, and all have their advantages and limitations. Multimodality molecular imaging combines instruments to utilize the advantages of modalities and to make up for the disadvantages of different modalities. So far, in vivo imaging of the ophthalmic molecular imaging has been largely applied in pre-clinical research using experimental animals by several research groups.
Molecular imaging depends on the development of specific and sensitive imaging agents, which is a pivotal step in the development of molecular imaging. Targeting moieties include small molecules, peptides, antibodies, and aptamers. These targeting moieties are applied to target imaging agents to recognize specific pathologic molecules [103]. Molecular probes are then detected. Molecular imaging is a potentially powerful tool for monitoring early events in retinal disease, such as apoptosis, cell injury, inflammation, and hypoxia. Frimmel et al. [104], in order to quantify the expression of retinal endothelial surface molecules in vivo, used α-ICAM-1 imaging probes to bind to ICAM-1. The results indicated that molecular imaging of retinal endothelial ICAM-1 could provide an early warning signal before clinical symptoms develop and can be used to detect subtle changes in the diabetic retina prior to the occurrence of irreversible pathology (Figure 5). Uddin et al. [105] suggest that, HYPOX-4, a new optical imaging probe, is capable of imaging retinal hypoxia in vivo in experimental RVO, before the onset of physiological changes leading to retinal cell damage and neovascularization. Tsuda et al. [106] injected molecular probe SYTOX orange (SO) into the vitreous of optic nerve crush (ONC) mice. With this, retinal ganglion cell (RGC) death was visualized with a confocal scanning laser ophthalmoscope (cSLO) in vivo. The study concluded that real-time imaging with SO was able to quickly quantify ONC-induced RGC death. This method may be an effective way to understand the pathogenesis of diseases involving RGC death, particularly glaucoma and to monitor disease progression. Recently, a new cutting–edge technology called “Detection of Apoptosing Retinal Cells” (DARC) has been reported to detect RGC apoptosis in vivo [107,108]. Annexin V is labeled with a fluorescent marker, such as FITC, bound to phosphotidylserine has been utilized as a sensitive probe for the identification of apoptosing cells [109,110]. The apoptosing cells can then be visualized using conventional ophthalmic imaging devices such as cSLO. It can detect RGC damage at a very early stage, at the moment apoptosis starts, even before visual field defects develop.
Recently, the application of nanotechnology has stimulated the development of imaging agents. Nanoparticles modified with unique and tunable optical properties, along with their small size and capacity for cellular targeting, make them as promising class of molecular imaging agents. It has been reported that gold nanoparticles have the potential for use as contrast agents with OCT. With multimodality imaging techniques clearly on the rise, the development has led to explosive growth in multimodal imaging agents [111]. Nanoparticles are attractive candidates for multimodal imaging probes [112]. Although there are few reports on the application of nanoparticles to ophthalmic multimodality imaging systems, molecular imaging is rapidly expanding and showing significant promise. With the ongoing advancement in theranostics, molecular imaging should not only be viewed solely as an imaging tool, but instead as a possible platform for the clinical application of nanotherapeutics.
While preclinical molecular imaging is useful in the development of nanomaterials or other agents, clinical molecular imaging is critical for the appropriate application of nanomaterials. Nevertheless, many critical challenges, including toxicity, biocompatibility, targeting efficacy, and long-term stability of nanomaterials, should be addressed for their clinical translation. It is also important to choose the most suitable nanomaterials and imaging modalities to obtain desired information. The sustainable development of nanotechnology in molecular imaging is expected to drive the next generation of diagnosis and therapy of diseases in the future.
8. Current Clinical Challenges and Future Directions in Retinal Optical Imaging
While optical imaging can provide unprecedented image resolution and speed, clinical challenges persist in the field. One clinical challenge is the lack of adequate biomarkers. Current imaging-based clinical biomarkers do not provide an adequate correlation between anatomy and function. For example, trials of anti-vascular endothelial growth factor therapy have demonstrated that visual acuity does not correlate with OCT thickness measurements. Also, OCTA reveals vasculature but has difficulty visualizing microaneurysms and leakage, the two primary reasons to acquire fluorescein angiograms. While we have seen great improvements in vascular imaging (e.g., OCTA), there remains limited ability to evaluate ischemia and hypoxia in tissue micro-environments. Several diseases can impede the ability of tissue to extract oxygen and nutrients even when present within vasculature, and thus moving from vascular analysis to extravascular tissue-level analysis becomes critical. While SLO and ultra-wide field imaging have improved our visualization of the periphery, there remain challenges in visualization of the far periphery and thus systems that provide an even wider field of view from ora serrata to the ora serrata are needed. Improved visualization and understanding is also needed of the choroid, which is being noted to play an increasingly important role in retinal diseases. There is also need for imaging the retina in patients with media opacities (e.g., vitreous hemorrhage, dense white cataracts, severe central keratitis, and total 8-ball hyphemas) where currently we can only perform low resolution 10 MHz B scan ultrasonography clinically.
Another challenge is the rapid interpretation and analysis of the large amount of data generated from these imaging modalities. With declining reimbursements, particularly for imaging, the amount of time retina specialists spend per patient has been reduced, with many physicians spending 5 to 10 min per patient to obtain a clinical history, examine, evaluate and interpret imaging, answer patient questions, educate patients, document, and treat patients. Thus, there is a need for computer-assisted interpretation and software to facilitate the rapid evaluation of the extensive data generated from these images. In addition, there is a clinical shortage of skilled and trained ophthalmic photographers, particularly in developing countries, and thus it is critical that new devices be developed that can be performed by minimally trained allied health care professionals without extensive training. While most imaging requires large table-top systems, there is further need for mobile imaging platforms, such as hand-held OCT and intra-operative OCT.
Medicine, retina, and therapies are increasingly driven by molecular and genetic changes, and thus there is a major clinical need for non-invasively determining molecular and genetic changes taking place in tissue. While one can acquire blood, aqueous humor, and even vitreous readily, getting tissue access of retina through biopsy is challenging with a significant risk of complications. Thus, there is a need for non-invasively measures of retina molecular markers to evaluate ischemia, inflammation, cell injury, and cell death which could necessitate multi-modal imaging platforms. There is also significant need for theranostics, where agents can both serve as diagnostic and therapeutic modalities.
9. Discussion/Conclusions
Optical imaging has played an indispensable role in giving us our current understanding of retinal and choroidal disease. We currently stand on the cusp of a revolution in retinal optical imaging with numerous recent advances, including OCT, OCTA, adaptive optics, SLO, fundus autofluorescence (FAF), photoacoustic microscopy (PAM), and molecular imaging. These imaging modalities have begun to transform our understanding of the molecular pathogenesis of retinal disease and are playing an increasing role in the early diagnosis and management of patients. Continuous innovations in imaging technology and progress in the understanding of retinal pathophysiology will make optical imaging continue to play a critical role in retinal diseases for many years to come.
Funding:
This work was supported by the generous support of the National Eye Institute 4K12EY022299 (Y.M.P.), Fight for Sight—International Retinal Research Foundation (Y.M.P.), and unrestricted departmental support from Research to Prevent Blindness (Y.M.P.).
Conflicts of Interest: The authors declare no conflict of interest. The funding sponsors had no role in the design of the study; in the collection, analyses, or interpretation of data; in the writing of the manuscript, and in the decision to publish the results.
References
- 1.Jackman W; Webster J On photographing the eye of the living human retina. Phila. Photogr 1886, 23, 340–341. [Google Scholar]
- 2.Huang D; Swanson EA; Lin CP; Schuman JS; Stinson WG; Chang W; Hee MR; Flotte T; Gregory K; Puliafito CA; et al. Optical coherence tomography. Science 1991, 254, 1178–1181. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 3.Gao SS; Jia Y; Zhang M; Su JP; Liu G; Hwang TS; Bailey ST; Huang D Optical coherence tomography angiography. Investig. Ophthalmol. Vis. Sci 2016, 57, OCT27–OCT36. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 4.Leitgeb R; Hitzenberger C; Fercher A Performance of fourier domain vs. Time domain optical coherence tomography. Opt. Express 2003, 11, 889–894. [DOI] [PubMed] [Google Scholar]
- 5.Yu S; Lu J; Cao D; Liu R; Liu B; Li T; Luo Y; Lu L The role of optical coherence tomography angiography in fundus vascular abnormalities. BMC Ophthalmol. 2016, 16, 107. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 6.Potsaid B; Baumann B; Huang D; Barry S; Cable AE; Schuman JS; Duker JS; Fujimoto JG Ultrahigh speed 1050 nm swept source/fourier domain OCT retinal and anterior segment imaging at 100,000 to 400,000 axial scans per second. Opt. Express 2010, 18, 20029–20048. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 7.Miller AR; Roisman L; Zhang Q; Zheng F; Rafael de Oliveira Dias J; Yehoshua Z; Schaal KB; Feuer W; Gregori G; Chu Z; et al. Comparison between spectral-domain and swept-source optical coherence tomography angiographic imaging of choroidal neovascularization. Investig. Ophthalmol. Vis. Sci 2017, 58, 1499–1505. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 8.Jia Y; Bailey ST; Wilson DJ; Tan O; Klein ML; Flaxel CJ; Potsaid B; Liu JJ; Lu CD; Kraus MF; et al. Quantitative optical coherence tomography angiography of choroidal neovascularization in age-related macular degeneration. Ophthalmology 2014, 121, 1435–1444. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 9.Moussa M; Leila M; Khalid H Imaging choroidal neovascular membrane using en face swept-source optical coherence tomography angiography. Clin. Ophthalmol 2017, 11, 1859–1869. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 10.Bonin T; Franke G; Hagen-Eggert M; Koch P; Hüttmann G In vivo fourier-domain full-field OCT of the human retina with 1.5 million a-lines/s. Opt. Lett 2010, 35, 3432–3434. [DOI] [PubMed] [Google Scholar]
- 11.Kang J; Feng P; Wei X; Lam EY; Tsia KK; Wong KK 102-nm, 44.5-MHz inertial-free swept source by mode-locked fiber laser and time stretch technique for optical coherence tomography. Opt. Express 2018, 26, 4370–4381. [DOI] [PubMed] [Google Scholar]
- 12.Klein T; Huber R High-speed OCT light sources and systems. Biomed. Opt. Express 2017, 8, 828–859. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 13.Klein T; Wieser W; Eigenwillig CM; Biedermann BR; Huber R Megahertz OCT for ultrawide-field retinal imaging with a 1050 nm fourier domain mode-locked laser. Opt. Express 2011, 19, 3044–3062. [DOI] [PubMed] [Google Scholar]
- 14.Poddar R; Migacz JV; Schwartz DM; Werner JS; Gorczynska I Challenges and advantages in wide-field optical coherence tomography angiography imaging of the human retinal and choroidal vasculature at1.7-MHz a-scan rate. J. Biomed. Opt 2017, 22, 1–14. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 15.Ferrara D; Mohler KJ; Waheed N; Adhi M; Liu JJ; Grulkowski I; Kraus MF; Baumal C; Hornegger J; Fujimoto JG; et al. En face enhanced-depth swept-source optical coherence tomography features of chronic central serous chorioretinopathy. Ophthalmology 2014, 121, 719–726. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 16.Lee WJ; Lee JW; Park SH; Lee BR En face choroidal vascular feature imaging in acute and chronic central serous chorioretinopathy using swept source optical coherence tomography. Br. J. Ophthalmol 2017, 101, 580–586. [DOI] [PubMed] [Google Scholar]
- 17.Dansingani KK; Balaratnasingam C; Naysan J; Freund KB En face imaging of pachychoroid spectrum disorders with swept-source optical coherence tomography. Retina 2016, 36, 499–516. [DOI] [PubMed] [Google Scholar]
- 18.Flores-Moreno I; Arias-Barquet L; Rubio-Caso MJ; Ruiz-Moreno JM; Duker JS; Caminal JM En face swept-source optical coherence tomography in neovascular age-related macular degeneration. Br. J. Ophthalmol 2015, 99, 1260–1267. [DOI] [PubMed] [Google Scholar]
- 19.Dastiridou AI; Bousquet E; Kuehlewein L; Tepelus T; Monnet D; Salah S; Brezin A; Sadda SR Choroidal imaging with swept-source optical coherence tomography in patients with birdshot chorioretinopathy: Choroidal reflectivity and thickness. Ophthalmology 2017, 124, 1186–1195. [DOI] [PubMed] [Google Scholar]
- 20.Lee B; Novais EA; Waheed NK; Adhi M; de Carlo TE; Cole ED; Moult EM; Choi W; Lane M; Baumal CR; et al. En face doppler optical coherence tomography measurement of total retinal blood flow in diabetic retinopathy and diabetic macular edema. JAMA Ophthalmol. 2017, 135, 244–251. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 21.Salz DA; de Carlo TE; Adhi M; Moult E; Choi W; Baumal CR; Witkin AJ; Duker JS; Fujimoto JG; Waheed NK Select features of diabetic retinopathy on swept-source optical coherence tomographic angiography compared with fluorescein angiography and normal eyes. JAMA Ophthalmol. 2016, 134, 644–650. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 22.Chalam KV; Sambhav K Optical coherence tomography angiography in retinal diseases. J. Ophthalmic Vis. Res 2016, 11, 84–92. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 23.Spaide RF; Klancnik JM Jr.; Cooney MJ Retinal vascular layers imaged by fluorescein angiography and optical coherence tomography angiography. JAMA Ophthalmol. 2015, 133, 45–50. [DOI] [PubMed] [Google Scholar]
- 24.Nagiel A; Sadda SR; Sarraf D A promising future for optical coherence tomography angiography. JAMA Ophthalmol. 2015, 133, 629–630. [DOI] [PubMed] [Google Scholar]
- 25.Moult E; Choi W; Waheed NK; Adhi M; Lee B; Lu CD; Jayaraman V; Potsaid B; Rosenfeld PJ; Duker JS; et al. Ultrahigh-speed swept-source OCT angiography in exudative AMD. Ophthalmic Surg. Lasers Imaging Retin 2014, 45, 496–505. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 26.Kashani AH; Chen CL; Gahm JK; Zheng F; Richter GM; Rosenfeld PJ; Shi Y; Wang RK Optical coherence tomography angiography: A comprehensive review of current methods and clinical applications. Prog. Retin. Eye Res 2017, 60, 66–100. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 27.Sambhav K; Grover S; Chalam KV The application of optical coherence tomography angiography in retinal diseases. Surv. Ophthalmol 2017, 62, 838–866. [DOI] [PubMed] [Google Scholar]
- 28.Zhang M; Hwang TS; Dongye C; Wilson DJ; Huang D; Jia Y Automated quantification of nonperfusion in three retinal plexuses using projection-resolved optical coherence tomography angiography in diabetic retinopathy. Investig. Ophthalmol. Vis. Sci 2016, 57, 5101–5106. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 29.Jia Y; Tan O; Tokayer J; Potsaid B; Wang Y; Liu JJ; Kraus MF; Subhash H; Fujimoto JG; Hornegger J; et al. Split-spectrum amplitude-decorrelation angiography with optical coherence tomography. Opt. Express 2012, 20, 4710–4725. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 30.Stanga PE; Tsamis E; Papayannis A; Stringa F; Cole T; Jalil A Swept-source optical coherence tomography Angio (Topcon Corp, Japan): Technology review. Dev. Ophthalmol 2016, 56, 13–17. [DOI] [PubMed] [Google Scholar]
- 31.Huang Y; Zhang Q; Thorell MR; An L; Durbin MK; Laron M; Sharma U; Gregori G; Rosenfeld PJ; Wang RK Swept-source OCT angiography of the retinal vasculature using intensity differentiation-based optical microangiography algorithms. Ophthalmic Surg. Lasers Imaging Retin. 2014, 45, 382–389. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 32.An L; Subhush HM; Wilson DJ; Wang RK High-resolution wide-field imaging of retinal and choroidal blood perfusion with optical microangiography. J. Biomed. Opt 2010, 15, 026011. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 33.Wang RK; An L; Francis P; Wilson DJ Depth-resolved imaging of capillary networks in retina and choroid using ultrahigh sensitive optical microangiography. Opt. Lett 2010, 35, 1467–1469. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 34.Wang RK; Jacques SL; Ma Z; Hurst S; Hanson SR; Gruber A Three dimensional optical angiography. Opt. Express 2007, 15, 4083–4097. [DOI] [PubMed] [Google Scholar]
- 35.Zhang Q; Wang RK; Chen CL; Legarreta AD; Durbin MK; An L; Sharma U; Stetson PF; Legarreta JE; Roisman L; et al. Swept source optical coherence tomography angiography of neovascular macular telangiectasia type 2. Retina 2015, 35, 2285–2299. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 36.Huang D; Jia Y; Gao SS; Lumbroso B; Rispoli M Optical coherence tomography angiography using the optovue device. Dev. Ophthalmol 2016, 56, 6–12. [DOI] [PubMed] [Google Scholar]
- 37.Rosenfeld PJ; Durbin MK; Roisman L; Zheng F; Miller A; Robbins G; Schaal KB; Gregori G Zeiss angioplex spectral domain optical coherence tomography angiography: Technical aspects. Dev. Ophthalmol 2016, 56, 18–29. [DOI] [PubMed] [Google Scholar]
- 38.Falavarjani KG; Al-Sheikh M; Akil H; Sadda SR Image artefacts in swept-source optical coherence tomography angiography. Br. J. Ophthalmol 2017, 101, 564–568. [DOI] [PubMed] [Google Scholar]
- 39.Eandi CM; Ciardella A; Parravano M; Missiroli F; Alovisi C; Veronese C; Morara MC; Grossi M; Virgili G; Ricci F Indocyanine green angiography and optical coherence tomography angiography of choroidal neovascularization in age-related macular degeneration. Investig. Ophthalmol. Vis. Sci 2017, 58, 3690–3696. [DOI] [PubMed] [Google Scholar]
- 40.Ting DSW; Tan GSW; Agrawal R; Yanagi Y; Sie NM; Wong CW; San Yeo IY; Lee SY; Cheung CMG; Wong TY Optical coherence tomographic angiography in type 2 diabetes and diabetic retinopathy. JAMA Ophthalmol. 2017, 135, 306–312. [DOI] [PubMed] [Google Scholar]
- 41.Durbin MK; An L; Shemonski ND; Soares M; Santos T; Lopes M; Neves C; Cunha-Vaz J Quantification of retinal microvascular density in optical coherence tomographic angiography images in diabetic retinopathy. JAMA Ophthalmol 2017, 135, 370–376. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 42.Agemy SA; Scripsema NK; Shah CM; Chui T; Garcia PM; Lee JG; Gentile RC; Hsiao YS; Zhou Q; Ko T; et al. Retinal vascular perfusion density mapping using optical coherence tomography angiography in normals and diabetic retinopathy patients. Retina 2015, 35, 2353–2363. [DOI] [PubMed] [Google Scholar]
- 43.Nesper PL; Roberts PK; Onishi AC; Chai H; Liu L; Jampol LM; Fawzi AA Quantifying microvascular abnormalities with increasing severity of diabetic retinopathy using optical coherence tomography angiography. Investig. Ophthalmol. Vis. Sci 2017, 58, BIO307–BIO315. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 44.Hwang TS; Gao SS; Liu L; Lauer AK; Bailey ST; Flaxel CJ; Wilson DJ; Huang D; Jia Y Automated quantification of capillary nonperfusion using optical coherence tomography angiography in diabetic retinopathy. JAMA Ophthalmol. 2016, 134, 367–373. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 45.Takase N; Nozaki M; Kato A; Ozeki H; Yoshida M; Ogura Y Enlargement of foveal avascular zone in diabetic eyes evaluated by en face optical coherence tomography angiography. Retina 2015, 35, 2377–2383. [DOI] [PubMed] [Google Scholar]
- 46.Ho J; Dans K; You Q; Nudleman EN; Freeman WR Comparison of 3 mm × 3 mm versus 6 mm × 6 mm optical coherence tomography angiography scan sizes in the evaluation of non-proliferative diabetic retinopathy. Retina 2017. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 47.Hirano T; Kakihara S; Toriyama Y; Nittala MG; Murata T; Sadda S Wide-field en face swept-source optical coherence tomography angiography using extended field imaging in diabetic retinopathy. Br. J. Ophthalmol 2017. [DOI] [PubMed] [Google Scholar]
- 48.Ghashut R; Muraoka Y; Ooto S; Iida Y; Miwa Y; Suzuma K; Murakami T; Kadomoto S; Tsujikawa A; Yoshimura N Evaluation of macular ischemia in eyes with central retinal vein occlusion: An optical coherence tomography angiography study. Retina 2017. [DOI] [PubMed] [Google Scholar]
- 49.Coscas F; Glacet-Bernard A; Miere A; Caillaux V; Uzzan J; Lupidi M; Coscas G; Souied EH Optical coherence tomography angiography in retinal vein occlusion: Evaluation of superficial and deep capillary plexa. Am. J. Ophthalmol 2016, 161. [DOI] [PubMed] [Google Scholar]
- 50.Kuehlewein L; Bansal M; Lenis TL; Iafe NA; Sadda SR; Bonini Filho MA; De Carlo TE; Waheed NK; Duker JS; Sarraf D Optical coherence tomography angiography of type 1 neovascularization in age-related macular degeneration. Am. J. Ophthalmol 2015, 160, 739–748. [DOI] [PubMed] [Google Scholar]
- 51.Roisman L; Zhang Q; Wang RK; Gregori G; Zhang A; Chen CL; Durbin MK; An L; Stetson PF; Robbins G; et al. Optical coherence tomography angiography of asymptomatic neovascularization in intermediate age-related macular degeneration. Ophthalmology 2016, 123, 1309–1319. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 52.Rosenfeld PJ; Brown DM; Heier JS; Boyer DS; Kaiser PK; Chung CY; Kim RY; Group MS Ranibizumab for neovascular age-related macular degeneration. N. Engl. J. Med 2006, 355, 1419–1431. [DOI] [PubMed] [Google Scholar]
- 53.Miere A; Querques G; Semoun O; Amoroso F; Zambrowski O; Chapron T; Capuano V; Souied EH Optical coherence tomography angiography changes in early type 3 neovascularization after anti-vascular endothelial growth factor treatment. Retina 2017, 37, 1873–1879. [DOI] [PubMed] [Google Scholar]
- 54.Novotny HR; Alvis DL A method of photographing fluorescence in circulating blood in the human retina. Circulation 1961, 24, 82–86. [DOI] [PubMed] [Google Scholar]
- 55.Coscas GJ; Lupidi M; Coscas F; Cagini C; Souied EH Optical coherence tomography angiography versus traditional multimodal imaging in assessing the activity of exudative age-related macular degeneration: A new diagnostic challenge. Retina 2015, 35, 2219–2228. [DOI] [PubMed] [Google Scholar]
- 56.Zhang HF; Maslov K; Stoica G; Wang LV Functional photoacoustic microscopy for high-resolution and noninvasive in vivo imaging. Nat. Biotechnol 2006, 24, 848–851. [DOI] [PubMed] [Google Scholar]
- 57.Li Y; Xia X; Paulus Y Novel retinal imaging technologies. Int. J. Ophthalmol. Eye Sci 2017, 5, 1–5. [Google Scholar]
- 58.Hu Z; Liu Q; Paulus YM New frontiers in retinal imaging. Int. J. Ophthalmic Res 2016, 2, 148–158. [Google Scholar]
- 59.Liu W; Zhang HF Photoacoustic imaging of the eye: A mini review. Photoacoustics 2016, 4, 112–123. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 60.Tian C; Feng T; Wang C; Liu S; Cheng Q; Oliver DE; Wang X; Xu G Non-contact photoacoustic imaging using a commercial heterodyne interferometer. IEEE Sens. J 2016, 16, 8381–8388. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 61.De la Zerda A; Paulus YM; Teed R; Bodapati S; Dollberg Y; Khuri-Yakub BT; Blumenkranz MS; Moshfeghi DM; Gambhir SS Photoacoustic ocular imaging. Opt. Lett 2010, 35, 270–272. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 62.Hu S; Rao B; Maslov K; Wang LV Label-free photoacoustic ophthalmic angiography. Opt. Lett 2010, 35, 1–3. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 63.Jiao S; Jiang M; Hu J; Fawzi A; Zhou Q; Shung KK; Puliafito CA; Zhang HF Photoacoustic ophthalmoscopy for in vivo retinal imaging. Opt. Express 2010, 18, 3967–3972. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 64.Linsenmeier RA; Zhang HF Retinal oxygen: From animals to humans. Prog. Retin. Eye Res 2017, 58, 115–151. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 65.Hennen SN; Xing W; Shui YB; Zhou Y; Kalishman J; Andrews-Kaminsky LB; Kass MA; Beebe DC; Maslov KI; Wang LV Photoacoustic tomography imaging and estimation of oxygen saturation of hemoglobin in ocular tissue of rabbits. Exp. Eye Res 2015, 138, 153–158. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 66.Song W; Wei Q; Liu W; Liu T; Yi J; Sheibani N; Fawzi AA; Linsenmeier RA; Jiao S; Zhang HF A combined method to quantify the retinal metabolic rate of oxygen using photoacoustic ophthalmoscopy and optical coherence tomography. Sci. Rep 2014, 4, 6525. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 67.Liu X; Liu T; Wen R; Li Y; Puliafito CA; Zhang HF; Jiao S Optical coherence photoacoustic microscopy for in vivo multimodal retinal imaging. Opt. Lett 2015, 40, 1370–1373. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 68.Tian C; Zhang W; Mordovanakis A; Wang X; Paulus YM Noninvasive chorioretinal imaging in living rabbits using integrated photoacoustic microscopy and optical coherence tomography. Opt. Express 2017, 25, 15947–15955. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 69.Kim J; Lee D; Jung U; Kim C Photoacoustic imaging platforms for multimodal imaging. Ultrasonography 2015, 34, 88–97. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 70.Song W; Wei Q; Feng L; Sarthy V; Jiao S; Liu X; Zhang HF Multimodal photoacoustic ophthalmoscopy in mouse. J. Biophotonics 2013, 6, 505–512. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 71.Godara P; Dubis AM; Roorda A; Duncan JL; Carroll J Adaptive optics retinal imaging: Emerging clinical applications. Optom. Vis. Sci 2010, 87, 930–941. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 72.Carroll J; Kay DB; Scoles D; Dubra A; Lombardo M Adaptive optics retinal imaging—clinical opportunities and challenges. Curr. Eye Res 2013, 38, 709–721. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 73.Webb RH; Hughes GW Scanning laser ophthalmoscope. IEEE Trans. Biomed. Eng 1981, 28, 488–492. [DOI] [PubMed] [Google Scholar]
- 74.Roorda A Applications of adaptive optics scanning laser ophthalmoscopy. Optom. Vis. Sci 2010, 87, 260–268. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 75.Dubra A; Sulai Y; Norris JL; Cooper RF; Dubis AM; Williams DR; Carroll J Noninvasive imaging of the human rod photoreceptor mosaic using a confocal adaptive optics scanning ophthalmoscope. Biomed. Opt. Express 2011, 2, 1864–1876. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 76.Kaizu Y; Nakao S; Wada I; Yamaguchi M; Fujiwara K; Yoshida S; Hisatomi T; Ikeda Y; Hayami T; Ishibashi T; et al. Imaging of retinal vascular layers: Adaptive optics scanning laser ophthalmoscopy versus optical coherence tomography angiography. Transl. Vis. Sci. Technol 2017, 6, 2. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 77.Tam J; Martin JA; Roorda A Noninvasive visualization and analysis of parafoveal capillaries in humans. Investig. Ophthalmol. Vis. Sci 2010, 51, 1691–1698. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 78.Chui TY; Zhong Z; Song H; Burns SA Foveal avascular zone and its relationship to foveal pit shape. Optom. Vis. Sci 2012, 89, 602. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 79.Liu Z; Kocaoglu OP; Miller DT 3D imaging of retinal pigment epithelial cells in the living human retina. Investig. Ophthalmol. Vis. Sci 2016, 57, OCT533–OCT543. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 80.Scoles D; Sulai YN; Dubra A In vivo dark-field imaging of the retinal pigment epithelium cell mosaic. Biomed. Opt. Express 2013, 4, 1710–1723. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 81.Liu Z; Kurokawa K; Zhang F; Lee JJ; Miller DT Imaging and quantifying ganglion cells and other transparent neurons in the living human retina. PNAS 2017. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 82.Miller D; Kocaoglu O; Wang Q; Lee S Adaptive optics and the eye (super resolution OCT). Eye 2011, 25, 321–330. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 83.Williams DR Imaging single cells in the living retina. Vis. Res 2011, 51, 1379–1396. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 84.Falavarjani KG; Wang K; Khadamy J; Sadda SR Ultra-wide-field imaging in diabetic retinopathy; An overview. J. Curr. Ophthalmol 2016, 28, 57–60. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 85.Falavarjani KG; Tsui I; Sadda SR Ultra-wide-field imaging in diabetic retinopathy. Vis. Res 2017, 139, 187–190. [DOI] [PubMed] [Google Scholar]
- 86.Silva PS; Cavallerano JD; Haddad NMN; Kwak H; Dyer KH; Omar AF; Shikari H; Aiello LM; Sun JK; Aiello LP Peripheral lesions identified on ultrawide field imaging predict increased risk of diabetic retinopathy progression over 4 years. Ophthalmology 2015, 122, 949–956. [DOI] [PubMed] [Google Scholar]
- 87.Kumar V; Chandra P; Kumar A Ultra-wide field imaging in the diagnosis and management of adult-onset coats’ disease. Clin. Exp. Optom 2017, 100, 79–82. [DOI] [PubMed] [Google Scholar]
- 88.Rabiolo A; Parravano M; Querques L; Cicinelli MV; Carnevali A; Sacconi R; Centoducati T; Vujosevic S; Bandello F; Querques G Ultra-wide-field fluorescein angiography in diabetic retinopathy: A narrative review. Clin. Ophthalmol 2017, 11, 803–807. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 89.Bae K; Cho K; Kang SW; Kim SJ; Kim JM Peripheral reticular pigmentary degeneration and choroidal vascular insufficiency, studied by ultra wide-field fluorescein angiography. PLoS ONE 2017, 12, e0170526. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 90.Campbell JP; Nudleman E; Yang J; Tan O; Chan RP; Chiang MF; Huang D; Liu G Handheld optical coherence tomography angiography and ultra–wide-field optical coherence tomography in retinopathy of prematurity. JAMA Ophthalmol. 2017, 135, 977–981. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 91.Espina M; Arcinue CA; Ma F; Camacho N; Bartsch D-UG; Freeman WR Analysis of a confocal scanning laser ophthalmoscope noncontact ultra-wide field lens system in retinal and choroidal disease. Retina 2015, 35, 2664–2668. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 92.Saleh MG; Campbell JP; Yang P; Lin P Ultra-wide-field fundus autofluorescence and spectral-domain optical coherence tomography findings in syphilitic outer retinitis. Ophthalmic Surg. Lasers Imaging Retin 2017, 48, 208–215. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 93.Zhang Y; Wang X; Rivero EB; Clark ME; Witherspoon CD; Spaide RF; Girkin CA; Owsley C; Curcio CA Photoreceptor perturbation around subretinal drusenoid deposits as revealed by adaptive optics scanning laser ophthalmoscopy. Am. J. Ophthalmol 2014, 158, 584–596. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 94.Delori FC; Dorey CK; Staurenghi G; Arend O; Goger DG; Weiter JJ In vivo fluorescence of the ocular fundus exhibits retinal pigment epithelium lipofuscin characteristics. Investig. Ophthalmol. Vis. Sci 1995, 36, 718–729. [PubMed] [Google Scholar]
- 95.Pichi F; Abboud EB; Ghazi NG; Khan AO Fundus autofluorescence imaging in hereditary retinal diseases. Acta Ophthalmol. 2017. [DOI] [PubMed] [Google Scholar]
- 96.Borrelli E; Lei J; Balasubramanian S; Uji A; Cozzi M; Sarao V; Lanzetta P; Staurenghi G; Sadda SR Green emission fluorophores in eyes with atrophic age-related macular degeneration: A colour fundus autofluorescence pilot study. Br. J. Ophthalmol 2017. [DOI] [PubMed] [Google Scholar]
- 97.Trichonas G; Traboulsi EI; Ehlers JP Correlation of ultra-widefield fundus autofluorescence patterns with the underlying genotype in retinal dystrophies and retinitis pigmentosa. Ophthalmic Genet. 2017, 38, 320–324. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 98.Wong E; Nivison-Smith L; Assaad NN; Kalloniatis M OCT and fundus autofluorescence enhances visualization of white dot syndromes. Optom. Vis. Sci 2015, 92, 642–653. [DOI] [PubMed] [Google Scholar]
- 99.Yung M; Klufas MA; Sarraf D Clinical applications of fundus autofluorescence in retinal disease. Int. J. Retin. Vitreous 2016, 2, 12. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 100.De Carvalho JER; Verbraak FD; Aalders MC; van Noorden CJ; Schlingemann RO Recent advances in ophthalmic molecular imaging. Surv. Ophthalmol 2014, 59, 393–413. [DOI] [PubMed] [Google Scholar]
- 101.Capozzi ME; Gordon AY; Penn JS; Jayagopal A Molecular imaging of retinal disease. J. Ocul. Pharmacol. Ther 2013, 29, 275–286. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 102.Chen ZY; Wang YX; Lin Y; Zhang JS; Yang F; Zhou QL; Liao YY Advance of molecular imaging technology and targeted imaging agent in imaging and therapy. Biomed. Res. Int 2014, 2014, 819324. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 103.James ML; Gambhir SS A molecular imaging primer: Modalities, imaging agents, and applications.Physiol. Rev 2012, 92, 897–965. [DOI] [PubMed] [Google Scholar]
- 104.Frimmel S; Zandi S; Sun D; Zhang Z; Schering A; Melhorn MI; Nakao S; Hafezi-Moghadam A Molecular imaging of retinal endothelial injury in diabetic animals. J. Ophthalmic Vis. Res 2017, 12, 175–182. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 105.Uddin MI; Jayagopal A; McCollum GW; Yang R; Penn JS In vivo imaging of retinal hypoxia using hypox-4-dependent fluorescence in a mouse model of laser-induced retinal vein occlusion (RVO). Investig. Ophthalmol. Vis. Sci 2017, 58, 3818–3824. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 106.Tsuda S; Tanaka Y; Kunikata H; Yokoyama Y; Yasuda M; Ito A; Nakazawa T Real-time imaging of RGC death with a cell-impermeable nucleic acid dyeing compound after optic nerve crush in a murine model. Exp. Eye Res 2016, 146, 179–188. [DOI] [PubMed] [Google Scholar]
- 107.Cordeiro MF; Migdal C; Bloom P; Fitzke FW; Moss SE Imaging apoptosis in the eye. Eye 2011, 25,545–553. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 108.Ahmad SS An introduction to DARC technology. Saudi J. Ophthalmol 2017, 31, 38–41. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 109.Coxon KM; Duggan J; Cordeiro MF; Moss SE Purification of annexin v and its use in the detection of apoptotic cells. Methods Mol. Biol 2011, 731, 293–308. [DOI] [PubMed] [Google Scholar]
- 110.Normando EM; Turner LA; Cordeiro MF The potential of annexin-labelling for the diagnosis and follow-up of glaucoma. Cell Tissue Res. 2013, 353, 279–285. [DOI] [PubMed] [Google Scholar]
- 111.Louie A Multimodality imaging probes: Design and challenges. Chem. Rev 2010, 110, 3146–3195. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 112.John R; Nguyen FT; Kolbeck KJ; Chaney EJ; Marjanovic M; Suslick KS; Boppart SA Targeted multifunctional multimodal protein-shell microspheres as cancer imaging contrast agents. Mol. Imaging Biol 2012, 14, 17–24. [DOI] [PMC free article] [PubMed] [Google Scholar]