Abstract
Background
Infections caught in buildings are a major global cause of sickness and mortality. Understanding how infections spread is pivotal to public health yet current knowledge of indoor transmission remains poor.
Aim
To review the roles of natural ventilation and sunlight for controlling infection within healthcare environments.
Methods
Comprehensive literature search was performed, using electronic and library databases to retrieve English language papers combining infection; risk; pathogen; and mention of ventilation; fresh air; and sunlight. Foreign language articles with English translation were included, with no limit imposed on publication date.
Findings
In the past, hospitals were designed with south-facing glazing, cross-ventilation and high ceilings because fresh air and sunlight were thought to reduce infection risk. Historical and recent studies suggest that natural ventilation offers protection from transmission of airborne pathogens. Particle size, dispersal characteristics and transmission risk require more work to justify infection control practices concerning airborne pathogens. Sunlight boosts resistance to infection, with older studies suggesting potential roles for surface decontamination.
Conclusions
Current knowledge of indoor transmission of pathogens is inadequate, partly due to lack of agreed definitions for particle types and mechanisms of spread. There is recent evidence to support historical data on the effects of natural ventilation but virtually none for sunlight. Modern practice of designing healthcare buildings for comfort favours pathogen persistence. As the number of effective antimicrobial agents declines, further work is required to clarify absolute risks from airborne pathogens along with any potential benefits from additional fresh air and sunlight.
Keywords: Airborne pathogens, Airborne transmission, Airborne transmission of infection, Hospital-acquired infection, Sunlight, Ventilation
We shape our buildings, and afterwards our buildings shape us.
Winston Churchill
Introduction
There is evidence that fresh air and sunlight penetration in buildings can influence the transmission of airborne pathogens.1, 2 Before the discovery of antibiotics, both ventilation and sunlight were considered important safeguards against infection.3 Now that microbial resistance is increasing, it may be helpful to review preventive strategies utilized during the pre-antibiotic era.4 Bioterrorism poses a further potential threat to public health indoors.5, 6, 7
Before considering the evidence for natural ventilation, there is a need to establish the range of pathogens that could potentially spread through the air along with their relative transmission risks. There is some confusion over types of airborne particles, modes of dispersal and risk of infection.8 Particles of different sizes pose different risks but current evidence does not provide assurance that infection control practices are appropriate for preventing transmission in hospitals.9 Furthermore, there is a paucity of work to support the relaxation of airborne precautions for convalescent patients with specific infections.
This article examines historical and current evidence supporting the effects of natural ventilation and sunlight in reducing the risk of infection in healthcare and home environments. Fresh air may provide additional microbiocidal and/or attenuating effects other than physical dilution or displacement of airborne pathogens. We examine current confusion over definitions of particle size, transmission characteristics and associated infection risk. Given the threat from escalating microbial resistance, it is timely to consider whether buildings could be designed or adapted to limit the risk from airborne pathogens, including those released with criminal intent.
Search strategy and selection criteria
An extensive literature search was performed, using electronic and library databases and personal files to retrieve English language papers combining any infection, pathogen, infection risk and mention of ventilation, fresh air and sunlight. Foreign language articles with English translation were also included. No limit was imposed on date.
Role of air in transmitting pathogens
Historical background
In 1864, Britain's Chief Medical Officer John Simon underlined the importance of natural ventilation in wards.10 Like Florence Nightingale, Simon supported oblong wards with sash windows reaching to the top along the two long sides, with sufficient space for one bed between each window.3 At the time, it was believed that smallpox and other infections were contracted following the inhalation of airborne material.11 The Victorians and Edwardians were preoccupied with ventilating their homes to stop the accumulation of ‘foul air’.12 Building codes and standards therefore set high ventilation rates in order to minimize the risk of airborne contagion.
In 1914, the British Admiralty recommended that the air change rate on the Royal Navy's ships should be 3000 cubic feet (85 m3) per man per hour.13 This was also recommended for British housing.14 By the 1920s, scientific opinion had turned against the airborne transmission of respiratory diseases. Aseptic surgery and barrier nursing had shown the importance of contact in hospital infection. It was thought that respiratory infections were transmitted by large droplets over short distances or through contact with freshly contaminated surfaces; not via the air, or dust.11 Natural cross-ventilation remained popular in hospitals, however, with open-air management of tuberculosis patients having a direct influence on hospital design.15
Following improvements in living conditions and anti-infective strategies, diseases such as tuberculosis, smallpox and others became less of a threat to public health. This eroded the importance of ventilation as an infection control strategy. Rather than construct buildings to prevent infection, the aim was to create comfortable conditions and remove odours produced by building occupants. Standards based on comfort remained in place until the 1973 Oil Embargo, when energy efficiency became a priority.16 There was increased use of recirculated air, particularly in commercial buildings. Air change rates were reduced to save fuel and money. The latter may have contributed towards so-called ‘sick building syndrome’, characterized by a range of symptoms including headache, fatigue, dry eyes and throat, nasal congestion and dry skin.16, 17
In 1976, an outbreak of Legionella pneumophila revived interest in indoor air quality in buildings, with the source traced to the ventilation and humidification system of a hotel.18 A decade later, New York City and other urban centres in the USA witnessed resurgence in tuberculosis, including multiple-drug-resistant strains.19, 20 Then in 2003, a new virus emerged, termed severe acute respiratory syndrome (SARS). The SARS pandemic illustrated the lack of scientific evidence underpinning minimum ventilation rate guidelines.21, 22
Current British guidance recommends passive natural ventilation rather than air-conditioning or mechanical ventilation in hospitals. This aims to control energy use and reduce carbon emissions, but it prioritizes patient comfort and containment of costs rather than infection control.23, 24 Whereas the risk of airborne transmission is recognized in specialist facilities such as operating theatres and isolation rooms, there is growing evidence that the airborne transmission of pathogens elsewhere has been underestimated.25, 26, 27 If this is true, the potential for ward ventilation to control infection needs to be reassessed, particularly with respect to increasing antimicrobial resistance, novel airborne pathogens and existing pathogens for whom an airborne route of transmission may only just be evident.
Mechanisms for airborne transmission of pathogens
Surprisingly little progress has been made in understanding how pathogens pass from one host to the next.28 Since the 1930s, four mechanisms of transmission have been described. These are: contact; dust; ‘respiratory droplets’ and ‘droplet nuclei’.11, 29 There is confusion in the literature regarding the definition of these particles and their mechanisms of spread. For example, ‘contact’ may be used to indicate inhalation of large droplets from contagious individuals when they cough or sneeze, i.e. droplet transmission, but ‘contact’ may also refer to infectious particles transmitted directly from contaminated surfaces.29 Aside from particle size, the potential for transmission depends upon dynamic factors, such as number of particles produced; velocity at which they are produced; number of micro-organisms contained within the spectrum of droplet sizes; infectious longevity of those microbes; and proximity of a susceptible target.9, 30
Large respiratory droplets fall on to horizontal surfaces, including the ground. They contribute towards the many and varied components of dust. Dust particles can be suspended and resuspended by activities such as dressing, sweeping, or bed-making.29 The range of these droplets is supposedly no more than 1 m, which suggests that anyone standing more than this distance from an infected person does not require protection.31 Resuspended dust and fibres from fabric, however, can easily be seen floating in air currents illuminated by beams of light during various energetic activities. Smaller respiratory droplets quickly evaporate, leaving residues which, in turn, become minute suspended particles or ‘droplet nuclei’.32 By contrast with larger droplets, these smaller particles can stay airborne for minutes to hours depending on size and density. Their size means that they could potentially penetrate deeper into lung tissues than droplets.9 Droplet nuclei are also exhaled during normal breathing and talking, although the number of particles exhaled during breathing and conversation are many orders of magnitude fewer than the aerosols produced by coughing or sneezing.9, 33
The importance and mode of airborne transmission has been a matter of dispute for decades and remains controversial.8, 34 The relative importance of droplets, droplet nuclei initially in air and raised again as a dust component, in the spread of respiratory infections remains unknown. All three modes of spread probably occur.35 Furthermore, there is no agreed classification of airborne particles.36 The cut-off diameter at which transmission changes from exclusively droplet to airborne droplet nuclei, or vice versa, has never been universally accepted, and indeed, may be impossible to determine. Nevertheless, current infection control procedures make a clear distinction between different types of droplet and the precautions required to prevent transmission according to presumed category of dispersal.37 The definitive test should be efficacy of a given infection control practice.
The survival of airborne pathogens depends partially on ambient environmental factors such as temperature and humidity (relative or absolute), as well as ultraviolet (UV) radiation and atmospheric pollutants.38 In addition, the movement of airborne droplets is affected by various other environmental factors, such as local ventilation airflows (including presence of vertical shafts), door opening, and movement of people, their clothes, and thermal gradients produced by electrical equipment.39, 40, 41
In healthcare premises, patients with accepted airborne infections, such as Mycobacterium tuberculosis, require the use of negative pressure isolation rooms. Anyone who enters an isolation room must wear a high filtration respirator, not just a surgical face mask.42 These precautions do not necessarily apply to diseases thought to be spread by droplet transmission such as influenza virus, rhinoviruses, adenoviruses and respiratory syncytial virus.43 If activities such as breathing, coughing, sneezing, and talking generate different sizes of particles, however, both droplets and droplet nuclei could be produced simultaneously. A recent literature review concluded that infection control precautions should be revised, so that airborne risk is considered whenever potentially infectious aerosols are generated, whatever the size of droplets.9
The following sections summarize current knowledge on transmission and control of a variety of pathogens, all of which may be dispersed into the air as infectious particles in one form or another.
Influenza
Influenza continues to have a major impact on global health, but knowledge of its transmission and control remains poor.44, 45, 46 Infection control is based on the assumption that influenza is transmitted by large droplets but it is possible that aerosol transmission is responsible for the most severe cases of influenza involving the lower respiratory tract.47 A report from 1979 describes an event involving transmission of influenza aboard an airliner, the particular circumstances of which seem to support airborne transmission of the virus over distances greater than a few metres.48
The possibility of aerosol transmission assumes greater importance when considering recent H5N1 avian influenza, which has demonstrated high virulence and lethality.49 Until recently, this form of influenza could only pass between humans via physical contact.50 Most of the reported cases were traced to direct contact with diseased poultry and other birds.51 However, recent work suggests that H5N1 can be transmitted through the air following modification. Strains have been experimentally spread between mammals without recombination in an intermediate host.52 This illustrates the potential for human pandemic influenza and underlines the need to revise current infection control practices in hospitals.46
Smallpox
In the past, smallpox was more widely believed to be airborne than any other disease.11 When the World Health Organization launched its campaign to eradicate smallpox in the 1960s it did so on the basis that the virus spread by face-to-face contact.53 This assumption was challenged following a smallpox outbreak at a German hospital in 1970.54 The pattern of spread suggested airborne transmission of the virus, later supported by smoke tests. Another incident occurred in 1971 when a naval scientist contracted smallpox while offshore from a smallpox testing site in Kazakhstan.55 The virus travelled downwind over a distance of at least 15 km to reach the ship. This raised concerns that scientists in the former Soviet Union not only ‘weaponized’ smallpox, but succeeded in aerosolizing it. Further evidence for airborne transmission of smallpox came in 1978 when a medical photographer contracted the disease and died.56 The virus is thought to have dispersed via air currents up a service duct from a laboratory to the room where the victim worked.
Severe acute respiratory syndrome
The official investigation into the 2003 SARS epidemic assumed that direct contact, not air, was the main transmission route.21 Viruses such as SARS are shed in large numbers and survive for long periods on surfaces or objects commonly found indoors.57 Healthcare workers who avoided face-to-face contact with SARS patients were certainly at less risk of contracting the virus. This may have been due to decreased exposure to infected droplets.58 However, the Amoy Gardens outbreak in Hong Kong suggests that airborne transmission was also involved.59 It is possible that virus-laden aerosol from sewage passed through faulty floor drains into bathrooms, where further exposures occurred. Later investigation implied that contaminated air then rose up a ventilating shaft and prevailing winds carried it to adjacent buildings.59, 60
Further examples include the spread of SARS at a Hong Kong hospital, thought to be due to faulty ventilation, and transmission on aircraft, suggesting that airborne droplets may have infected passengers during two separate flights.61, 62, 63 Before SARS emerged, the dynamics of virus-laden aerosols had attracted little research, so little was known about control and prevention.28 The SARS epidemic confirmed that the mechanisms of respiratory disease transmission are still poorly understood.63
Hantavirus
Ten years before the SARS pandemic, hantavirus demonstrated transmission between animals and humans. It was widely accepted that this viral pathogen was airborne and could travel over distance. Hantavirus spreads to humans through the inhalation of aerosolized excreta and saliva from wild rodents.64 In 1993–2007 there were 2500 cases of hantavirus with an overall mortality of 30%. This is comparable to the mortality rate for SARS during the 2003 epidemic.65 A key preventive measure is ventilating rooms or buildings showing signs of rodent infestation, with staff advised to use disposable respirators and gloves during cleaning after the ventilation process.64, 66
Norovirus
Norovirus causes a significant amount of gastrointestinal illness in the developed world.67 This virus is easily transmitted between individuals, via contact with contaminated surfaces, food, and/or through aerosol spread.68 A recent review of hospital outbreaks concluded that 18.5% were caused by person-to-person transmission; 3.7% were foodborne; and infection route for the remaining 77.8% was unknown.69 The latter may be due to aerosolized particles from vomiting or liquid diarrhoea. A sick person can produce 107 virus particles per millilitre of vomit whilst faecal material contains up to 1012 viruses per gram.27 Projectile vomiting is likely to be a major source of cross-infection and droplets generated by flushing toilets can be inhaled or deposited on surfaces.27, 70 The high attack rates seen during norovirus outbreaks could be due to rapid dispersal via aerosols.71, 72
Common cold
Adults suffer between two and five colds each year, usually caused by rhinoviruses.27, 73 Despite years of study, transmission between individuals remains controversial. There is evidence that sharing office space increases the risk of catching a cold.74 A study in mechanically ventilated office buildings found additional evidence for aerosol transmission of rhinovirus, when a low outdoor air supply resulted in an increased risk of inhaling infectious droplets.75 A more recent study found that students accommodated in six-person rooms were twice as likely to have colds as students in three-person rooms.76 Some 35% of students caught more than six colds each year when the ventilation rate was 1 L/s/person. If this rate was increased to 5 L/s/person, the number of students catching colds six times or more fell to 5%, suggesting that there was an association between colds and outdoor-to-indoor air flow rates; this reflects the multifactorial nature of the spread of such respiratory infections. There is evidence that hand-to-surface contacts are of greater significance, at least for respiratory syncytial virus.77 Nevertheless, ventilation may still be important in diluting and dispersing virus-laden droplets than is currently appreciated.78
Tuberculosis
The transmission of tuberculosis, like human viral infections, is assumed to be an indoor event. Improved housing is one of a number of factors thought to explain the decline of tuberculosis in Britain from the mid-19th century onwards.79 Since tuberculosis is mainly contracted through airborne droplets, it follows that transmission of M. tuberculosis to a non-infected person is more likely if there is overcrowding and poor ventilation.80 Anyone who lives and sleeps in the same household as an infected person is at risk. Similarly, there is greater risk of contracting the disease in confined environments such as prisons, homeless shelters and long-term care facilities.20 Studies on ventilation issues and transmission risk of tuberculosis in private houses have received little attention, in company with most other respiratory infections.81 Statistics from the USA in 2002 put the healthcare costs of building-influenced communicable respiratory infections, including tuberculosis, at US$10 billion.78
Staphylococcus aureus
Hospital patients continue to be at risk from meticillin-resistant Staphylococcus aureus (MRSA).82 Hands are presumed to be the main vehicle for transmission, but airborne contribution has been suspected since the 1960s.83, 84 This may be linked to daily shedding of 106–107 skin cells from colonized or infected patients.41 A staphylococcal carrier with a cold also facilitates spread and has been termed the so-called ‘cloud adult’.85 Nasal cavities of susceptible adults become colonized with S. aureus by inhaling particles from the air.86, 87 This type of transmission is more likely when there is increased people-traffic or activities such as bed-making that precipitate air turbulence.25, 88 Recent experimental work shows that MRSA bioaerosols can deposit throughout a room with no clear correlation between relative surface concentration and distance from source.89 Burns patients are particularly susceptible to staphylococcal infection, with airborne transmission implicated in outbreaks in hospital burns units.90, 91, 92
More recently, community strains have emerged that infect healthy young people who have not had prior hospital exposure.93 It is known that persons with MRSA infection and/or carriage will readily disperse their strain throughout the home environment.94 Contamination of household surfaces could play a major role in community-acquired MRSA, but the health effects associated with exposure to airborne S. aureus in housing have not yet been investigated.95
Aerial spread of other pathogens
Traditional airborne pathogens, such as aspergillus and Bacillus spp., are found throughout hospitals, particularly during hot, dry weather. These have also been associated with construction or renovation.96, 97 Other pathogens have demonstrated aerial spread in healthcare facilities, including Escherichia coli, klebsiella, acinetobacter, pseudomonas and Clostridium difficile.98, 99, 100, 101, 102 Patients infected with C. difficile shed large numbers of spores in faeces, contaminating skin, bedding and nearby surfaces. Symptomatic patients increase the risk of airborne spores, which fall to the ground at a rate dependent on spore size.102 Another potential source of spread is the lidless toilet frequently installed in hospitals. When a toilet is flushed without a closed lid, aerosol production may contaminate the surrounding environment with C. difficile.103 The potential for airborne transmission of C. difficile is not adequately addressed by current control measures.104
Preventing infection through ventilation
The open air factor
The majority of microbes that cause airborne infections cannot tolerate sunlight, oxidants or the temperature extremes that occur outdoors. Both the Nightingale ward and tuberculosis sanatorium were designed to make conditions indoors as close as possible to those outdoors.3, 105 There may be an additional protective effect other than dilution of pathogens from high ventilation rates. In 1894, it was noticed that exposure to fresh air appeared to reduce the virulence of the tubercle bacillus. Whereas this effect persisted in well-ventilated dark spaces, tubercles retained their infectivity for long periods in the absence of fresh air or confined air.106 In the 1960s, the lethality of outside air to micro-organisms was rediscovered and the term ‘open air factor’ (OAF) was introduced.107, 108 Further research showed that this ephemeral property of outdoor air had an adverse effect on viability and virulence of airborne micro-organisms, including influenza and the Category IV pathogen, Francisella tularensis.109, 110 These natural disinfection characteristics of outdoor air were then ignored for more than two decades.36
Whereas the OAF disappears rapidly in any form of enclosure, it is possible to ventilate experimental containers at rates that enable the germicidal properties of open air to be fully retained.107 More recently, an automated air disinfection system has been shown to reduce both airborne microbial counts and environmental contamination in the healthcare environment.111 The system produces hydroxyl radicals from a reaction of ozone and water vapour catalysed by an olefin (d-limonene).112 Hydroxyl radicals may be present in open air, with the main source of hydroxyl being the photolysis of ozone – this could relate to the ‘open air factor’. Hydroxyl radicals have been shown to possess disinfection characteristics.111 Despite widespread acceptance of the germicidal effect of fresh air over a century ago, it remains unknown whether maintaining high natural ventilation rates in buildings would preserve the OAF and its effects on indoor pathogen counts.106
Open windows
Natural ventilation has a number of advantages, including relatively low cost and low maintenance. Another advantage of open doors and windows is that air can enter a building by more than one route, whereas air must enter through a specified intake with mechanical systems. This is arguably more relevant regarding malicious dispersal of toxic chemicals or biological agents. Following the 2001 anthrax attacks, it was recommended that air intakes should be relocated to publicly inaccessible locations, with intakes on large buildings placed on secure roofs or high sidewalls.113 Mere presence of doors and windows, however, is no guarantee that they will be regularly utilized to encourage air movement. In addition, hospitals cannot necessarily keep windows open during unfavourable climatic conditions.114
Further disadvantages of using open windows include safety issues and entry of unfiltered air containing outdoor air contaminants such as fungal spores.115, 116 Whether originating from occupant or outside air, the quantity of potential pathogens in window-ventilated rooms is not necessarily higher than those in mechanically ventilated rooms.117 In British hospitals, a maximum opening of 100 mm is recommended for windows within reach of patients.118 The risk of unsupervised patients injuring themselves has to be weighed against cross-infection due to inadequate ventilation but window design could encompass both ventilation and patient safety. Designing buildings for human comfort rather than health may influence the ecology of indoor microbes.117
Natural versus mechanical ventilation
There is some evidence that natural ventilation can be more effective than mechanical systems for preventing transmission. During the 1918 influenza pandemic, sick patients who were accommodated in the open air survived in greater numbers than those in hospital wards.105, 119, 120 Eighty years later, during Operation Desert Shield, respiratory tract infections were more frequent in military personnel in air-conditioned barracks than among those housed in tents.121 A 1971 Scottish study reported that patients transferred from an old Nightingale-type ward to a mechanically ventilated ward had significantly fewer staphylococcal infections.122 This did not necessarily confirm superiority of mechanical over natural ventilation for reducing infection because respective ventilation rates for both wards were not included. Nightingale wards were designed for cross-ventilation via open windows but smoke tests showed that the old ward had no set ventilation pattern, other than ‘wild’ air streams from sporadically opened windows.122 There may also have been less staphylococcal debris in dust in a new ward.
In 2007, researchers measured natural ventilation in 70 different rooms containing tuberculosis patients.123 Air exchange rates in wards and outpatient areas were compared with those in mechanically ventilated negative-pressure isolation rooms, with an airborne infection model used to predict the effect on tuberculosis transmission. The highest risk of infection occurred in mechanically ventilated rooms with sealed windows, despite being ventilated at recommended rates. By contrast, clinical rooms with high ceilings and multiple large windows in pre-1950 hospitals gave the greatest protection, even if the windows were only partially open.123
Naturally ventilated wards can achieve higher air change rates than those with mechanical systems.124 Measurements on general wards found higher rates than the 12 air changes per hour specified for isolation rooms. In a ward with open doors and windows, cross-ventilation and a strong breeze, the maximum rate was 69 air changes per hour. Even without cross-ventilation, rates were between 14 and 31.6 air changes per hour.124 Case studies from China show that cross-ventilation is useful for controlling SARS transmission in hospitals.125 In addition, isolation wards with a high proportion of operable windows were more effective in preventing outbreaks of SARS among healthcare workers.126 A study from Thailand reported that air change rates in naturally ventilated hospital rooms were mostly higher than recommended standards. By contrast, ventilation rates in work areas with air-conditioning were often inadequate. This was most pronounced where there was a high risk for nosocomial tuberculosis infection such as radiological and emergency room departments.127
Ventilation systems in hospitals may be compromised by poor design, construction or inadequate maintenance, and these failings have been implicated in outbreaks of tuberculosis.123 Contaminated hospital ventilation systems have also been blamed for other types of outbreak.128, 129 The source of a Serratia marcescens outbreak in a baby unit of a hospital in United Arab Emirates was traced to an air conditioner duct.130 Faulty and/or contaminated ventilation systems have also been linked with outbreaks of MRSA.131, 132, 133
Ventilation in the home
Data from Germany, Canada, and the USA show that people spend most of their time indoors in private homes.134, 135, 136 According to one estimate, more than half of the body's intake of air during a lifetime is inhaled indoors.137 New homes in Britain and other countries make increasing use of mechanical ventilation. There is no evidence that mechanical ventilation has facilitated the spread of infection in houses, although a wide range of micro-organisms, including pathogens, may be found indoors.138 In 2012, a study of 299 mechanically ventilated Dutch homes identified major problems with the installation, operation and maintenance of ventilation systems in homes.139 Researchers found dust and dirt in the air supply ducts in 67% of houses fitted with mechanical ventilation heat recovery (MVHR). Air filters were dirty in almost half, with insufficient ventilation in at least one room, and exhaust air being recirculated in more than half of houses with MVHR. Most occupants did not control ventilation systems as recommended, nor use the highest ventilation settings due to noise levels.139
Preventing infection by sunlight
Historical background
In 1877, Downes and Blunt reported that sunlight inhibited the growth of bacteria from behind glass.140 Later studies showed that sunlight could kill a range of bacteria, including those causing tetanus, typhoid, anthrax and tuberculosis.141 In 1890, Koch reported that direct sunlight could kill the bacillus in a few minutes, or several hours, through glass. The time depended on the thickness of the layer of bacteria exposed. Furthermore, ordinary diffuse daylight, such as is found near windows in houses, could kill the bacterium in five to seven days.142 Even before this, it was recognized that tuberculosis transmission was less likely to occur in clean, well-lit, well-ventilated houses or hospitals.106
During the 1920s, manufacturers produced glass that transmitted a greater proportion of UV radiation than achieved by ordinary glass. Solar radiation was popular at this time, so encouraging a greater proportion of sunlight into buildings was a logical development.143 In 1930, the bactericidal power of direct sunlight, sunlight through plate glass, and sunlight through a commercial glass product (Vitaglass) was tested against S. aureus.144 Exposure times ranged from 30 min in good weather to 3 h in variable conditions. Nearly three-quarters of S. aureus were killed by unfiltered sunlight, half died when Vitaglass was used and one-quarter died following sunlight exposure through ordinary glass.144 These experiments were performed nearly a century ago, remain unverified and have not been recently explored.
The World Health Organization refers to sunlight in guidance on preventing hospital infections, although reasons for this are not made clear.145 For airborne infections such as tuberculosis, one document recommends that patients should be placed in single rooms with sunlight, negative air pressure and six to 12 air changes per hour. Guidelines on healthy housing state that natural lighting should be provided for toilets, preferably using special glass that transmits a higher proportion of UV rays. If ordinary window glass is fitted, windows should be left open in warm weather for at least 3 h in order to allow penetration by shorter wavelength UV radiation, presumably to exert some bactericidal effect.146
Mycobacteria and sunlight
Direct sunlight kills M. tuberculosis but diffuse light is less effective.147 A study from 1942 investigated the risk of tuberculosis infection among staff and patients in a Californian sanatorium. Patients were treated according to the ‘open air’ regimen where they were exposed to the elements day and night.148 Environmental cultures from hand-touch sites, dust and air samples in the ward were all negative. Further investigations suggested that tubercle bacilli exposed through an unglazed north window died within four or five days depending upon original inoculum. Bacilli survived for two or three months in a drawer in the same room, for six months in a refrigerator and for longer in winter than in summer.148 These studies have not been verified in recent times.
Streptococci and sunlight
Hospital dust near patients' beds was found to contain large numbers of streptococci during a 1944 outbreak of scarlet fever.149 Environmental screening demonstrated the absence of viable streptococci in dust at sites near windows. Previous work had already confirmed the lethal effect of sunlight on Streptococcus pyogenes.150, 151 Studies showed that streptococci could survive for long periods indoors with undiminished virulence, but only about 5 min in the sun compared with more than an hour in diffuse daylight.151 Garrod commented,
Although good lighting is universally recognised as desirable, it has never, so far as I am aware, been insisted on as a prime necessity in wards for septic surgical cases … preoccupation with the ultraviolet part of the spectrum has led to a common belief that only direct sunlight is usefully bactericidal; it must now be recognized that ordinary diffuse daylight, even on a cloudy day and even in winter in England, can be lethal to bacteria, and that glass is no absolute bar to this effect.149
Diffuse daylight is more rapidly lethal for the pneumococcus than for S. pyogenes. A 1905 study showed that exposing dried sputum to sunlight inactivates S. pneumoniae within half an hour.152 This illustrates the difficulty in separating out the effects of desiccation from that of light. Later, it was found that pneumococci in dried sputum exposed to diffuse daylight remained viable and retained virulence for extended periods of time.153 Pneumococci can survive in sputum, with airborne transmission thought to be possible.150, 154 There are no recent studies on pneumococcal survival in the environment and no additional evidence for airborne transmission.
Meningococci and sunlight
It is assumed that the meningococcus cannot withstand desiccation. In 1944, two linked studies showed that virulent organisms were recovered from a range of surfaces one week or more after drying and storing in a cupboard.155, 156 Meningococci were then exposed to different intensities of natural light. Direct sunlight passing through an ordinary window killed the organisms within a few hours, with less effect from diffuse daylight through a north-facing window. During cloudy weather, meningococci died more rapidly near a window than 12 feet away. Tests with coloured filters showed that whereas red light had little impact on meningococcal viability, blue light was highly bactericidal. Lethality of light transmitted by coloured filters of orange, green and yellow was proportional to the amount of blue light each filter transmitted.156 None of this work has since been repeated.
Staphylococci and sunlight
As noted above, sunlight also kills staphylococci. Cultures were exposed to sunlight for 45 min shielded by photocopier paper, window glass and Perspex.157 The bactericidal effect of sunlight was marginally reduced by the glass filter, whereas Perspex partially protected the staphylococci and photocopying paper inhibited the killing effect. Lethality of sunlight against staphylococci is due to radiation at 300–380 nm, with further effects apparent at shorter and longer wavelengths. In addition to bactericidal effect, solar radiation is mutagenic. It has long been believed that exposing clothing and bed linen to sunshine reduces the risk of staphylococcal contamination.157
Later tests show that unfiltered sunlight kills staphylococci within 70 min of exposure.158 Partial filtering of the UV-B component of sunlight (280–315 nm) using Perspex marginally reduces this effect. Cells took longer to die when UV-B was blocked in order to allow exposure to UV-A (315–400 nm) and visible radiation. Ordinary window glass absorbs solar radiation at <300 nm, which permits entry of solar UV-A and small amounts of UV-B. This would be lethal to staphylococci over time.158
Disinfection with artificial light
There are some older studies demonstrating the bactericidal effect of artificial light.159, 160, 161 UV wavelengths inactivate micro-organisms by causing cross-links between constituent nucleic acids. The absorption of UV can result in the formation of intra-strand cyclobutyl-pyrimidine dimers within DNA, which lead to mutations and/or cell death. This lethal effect of UV radiation is primarily due to the structural defects caused when thymine dimers form but secondary damage is also produced by cytosine dimers. There are other types of photoproducts that can contribute towards cell death.162 High-intensity narrow-spectrum light (HINS-light) is a modern light-based disinfection method that can inactivate a wide range of bacterial pathogens.163 The HINS-light method utilizes a narrow bandwidth of high-intensity visible violet light with peak output at 405 nm. Inactivation of bacteria by exposure to high-intensity light is thought to be associated with photo-excitation of certain molecules (porphyrins) within the bacteria. This results in the production of highly reactive compounds such as singlet oxygen which are strongly bactericidal.164 HINS-light has already been assessed for its efficacy in decontaminating the clinical environment but has not yet been linked to correspondingly lower rates of hospital infection.165
Sunlight and resistance to infection
Direct sunlight may enhance well-being and resistance to infection for those who receive it; even from behind glass. Bright-light therapy is used to treat a range of psychiatric conditions including seasonal and major depression.166 Hospital patients in sunlit wards recover better from depressive illness and other conditions, with sunlight having a positive effect on the length of stay, mortality rate, perceived stress and pain.167, 168, 169 Bright light also has benefits beyond relieving the symptoms of depression, since increasing light levels slows down the rate of cognitive decline in dementia patients.170 Without proper time-cues from the sun, or other sources, underlying body rhythms may become disturbed to cause a range of health problems, including depression, diabetes, obesity, and breast and prostate cancer.171 Regulating biological rhythms in patients may enhance immunological activity but it is not known whether habitual exposure to sunlight behind glass would help patients withstand infection.172
Solar infra-red radiation and infection
Infra-red radiation may also have a health impact on patients indoors. Roman villas and baths used to have a glazed sun-room called a ‘heliocaminus’ or solar furnace.173 In Scandinavian countries, saunas have been popular for hundreds of years, with evidence of health benefits.174 Passive solar design provides building occupants with radiant heat, which acts on the surface of the body as well as deeper-lying tissues. Infra-red radiation encourages wound-healing and relieves pain.175, 176, 177
Although light treatment in winter may alleviate seasonal depression, summertime usually brings spontaneous remission.178 It is possible that seasonal variations in the infra-red component of solar radiation may affect mood states. Like the visible spectrum, infra-red may also have an antidepressant effect, which could itself influence resistance to infection.179 Direct evidence of this in humans is lacking, although infra-red light has been shown to enhance immune response and wound-healing in mice with meticillin-susceptible Staphylococcus aureus (MRSA) skin infections.175, 180 In humans, infra-red irradiation inactivates fungal and other pathogens, as well as MRSA in the nasal passages of carriers.181
Sunlight through glass
During the 1920s, it was found that children develop rickets if they stay out of the sun.182 Ordinary window glass filters out the UV radiation that produces vitamin D. A study in 1933 found that exposing rachitic rats to sunlight through window glass improved resistance to infection without alleviating rickets.183 It is now accepted that vitamin D is involved in the functioning of the immune system but the immunological effect of sunlight through window glass has not been further explored.184 Sunrooms used to be a standard feature of hospitals.185 Whereas there is renewed appreciation that patients could benefit from sunlight, solar gains have to be minimized to prevent overheating.23 This might reduce the need for air-conditioning, but the exclusion of sunlight in hospitals, and indeed, other buildings, increases risk of infection, depression and other health problems. Greater sunlight exposure might encourage faster recovery for patients.186
Conclusion
Before the advent of antibiotics, ventilation and natural light were considered to be important safeguards against infection. Nowadays, there is less emphasis on fresh air and light in buildings. Many of the studies in this review were conducted a long time ago, which makes it difficult to assess the evidence in relation to modern hospitals. There is some justification in reviewing current lighting or ventilation arrangements for better protection of patients and staff from airborne contagion.
Despite more than a century of infection study, detailed specifications needed to prevent airborne dispersal of pathogens are still unknown, with ongoing controversy over the importance of airborne spread for certain pathogens.8, 187, 188 There is lack of consensus on particle size, transmission characteristics and associated infection risk. Scientists disagree over the number of changes required to dilute airborne pathogens such as SARS or avian influenza, as well as efficacy of natural cross-ventilation systems for control purposes. This means that infection control staff do not know how to manage isolation or droplet precautions for patients with airborne infections. There are also insufficient data to advise on ventilation requirements for non-hospital buildings.1, 114
Bioterrorism poses a further potential threat to public health indoors.5 Recent anthrax attacks exposed the vulnerability of building occupants to airborne pathogens and there is a concern that other aerosolized agents could be used for bioterrorism.6 It is therefore timely to re-examine ventilation requirements for infection control along with those for overall comfort.8 The same may be true for sunlight and its components, despite unverified science.189 Examples of older hospitals and other buildings structurally compatible for both comfort and health might offer a starting point.
Nowadays, building codes and regulations specify highly insulated sealed structures to meet government ‘zero carbon’ targets. As insulation levels have risen, so have the risks of overheating and poor indoor air quality.190 Typically, the heating in new buildings is provided by warm air, whereas heating in older ones was often from a radiant source.191 One advantage of radiant heating is that air temperatures can be kept lower than with convective systems. Since radiant sources heat internal surfaces rather than air, comfortable conditions can be maintained at lower air temperatures.192 The potential for energy savings and the health benefits of radiant heating have been overlooked in recent years.191 When Florence Nightingale set out to create healthy indoor environments, she insisted on radiant heat in sick rooms because she felt that air heated by metal surfaces was unhealthy. As she put it: ‘To shut your patients tight in artificially warmed air is to bake them in a slow oven.’3 She believed that combining warm-air heating and mechanical ventilation was especially harmful because it prevented or delayed recovery.
Nightingale was so opposed to warm-air heating that she called for it to be removed from hospitals along with mechanical ventilation. Any increase in fuel costs would be offset by the reduction in treatment time for patients.3 Later, during the 1920s, the British physiologist Sir Leonard Hill reported that the human body requires the stimulus of a constantly changing environment; and that monotonous over-warm indoor conditions are harmful. In common with Nightingale, he recommended sunlight, fresh air and radiant heating.193 Detailed research on indoor air quality and other health factors in today’s energy-efficient buildings is lacking.194 Present-day buildings may perform better in energy terms than older designs, but the exclusion of sunlight and fresh air could encourage poor health and associated costs.
In conclusion, designing buildings to allow increased exposure to sunlight and outdoor air may discourage survival and spread of infectious agents with consequential health benefits for occupants.2, 3 Most of the evidence in this review comes from the pre-antibiotic era and much of it has since been overlooked. Given the continuing decline in antimicrobial agents, and risk of future pathogens or modified pathogens, potential benefits from sunlight penetration and natural ventilation merit further investigation.
Acknowledgements
The authors are grateful for the helpful comments and suggestions provided by the reviewers.
Conflict of interest statement
None declared.
Funding source
R.H. received funding from Velux A/S Copenhagen for initial data collection and preliminary draft.
References
- 1.Li Y., Leung G.M., Tang J.W. Role of ventilation in airborne transmission of infectious agents in the built environment – a multidisciplinary systematic review. Indoor Air. 2007;17:2–18. doi: 10.1111/j.1600-0668.2006.00445.x. [DOI] [PubMed] [Google Scholar]
- 2.Hobday R.A. Sunlight therapy and solar architecture. Med Hist. 1997;42:455–472. doi: 10.1017/s0025727300063043. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 3.Nightingale F. 3rd ed. Longman, Roberts & Green; London: 1863. Notes on hospitals. [Google Scholar]
- 4.Gould I.M. Antibiotic resistance: the perfect storm. Int J Antimicrob Agents. 2009;34:S2–S5. doi: 10.1016/S0924-8579(09)70549-7. [DOI] [PubMed] [Google Scholar]
- 5.Wallin A., Luksiene Z., Zagminas K., Surkiene G. Public health and bioterrorism: renewed threat of anthrax and smallpox. Medicina (Kaunas) 2007;43:278–284. [PubMed] [Google Scholar]
- 6.Utrup L.J., Frey A.H. Fate of bioterrorism-relevant viruses and bacteria, including spores, aerosolized into an indoor air environment. Exp Biol Med. 2004;229:345–350. doi: 10.1177/153537020422900409. [DOI] [PubMed] [Google Scholar]
- 7.Fleck F. Conference warns of danger of re-emergence of smallpox as weapon of bioterror. Bull WHO. 2003;81:917–918. [PMC free article] [PubMed] [Google Scholar]
- 8.Eames I., Tang J.W., Li Y., Wilson P. Airborne transmission of disease in hospitals. J R Soc Interface. 2009;6(Suppl. 6):S697–702. doi: 10.1098/rsif.2009.0407.focus. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 9.Gralton J., Tovey E., McLaws M.L., Rawlinson W.D. The role of particle size in aerosolised pathogen transmission: a review. J Infect. 2011;62:1–13. doi: 10.1016/j.jinf.2010.11.010. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 10.Simon J. HMSO; London: 1864. Sixth Report of the Medical Officer of the Privy Council. House of Commons Parliamentary Papers. [Google Scholar]
- 11.Chapin C.V. Wiley & Sons; New York: 1910. The sources and mode of infection. [Google Scholar]
- 12.Mosley S. Fresh air and foul: the role of the open fireplace in ventilating the British home, 1837–1910. Plann Perspect. 2003;18:1–21. [Google Scholar]
- 13.Ellis F.P. Victuals and ventilation and the health and efficiency of seamen. Br J Ind Med. 1948;5:185–197. doi: 10.1136/oem.5.4.185. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 14.Macey F.W. 3rd ed. Crosby Lockwood & Son; London: 1905. Specifications in detail. [Google Scholar]
- 15.Watt J. The ventilation, heating and lighting of hospital wards. Proc R Soc Med. 1933;26:1411–1426. [PMC free article] [PubMed] [Google Scholar]
- 16.Mendell M., Fine L. Building ventilation and symptoms – where do we go from here? Am J Publ Health. 1994;84:346–348. doi: 10.2105/ajph.84.3.346. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 17.Menzies D., Bourbeau J. Building-related illnesses: current concepts. N Engl J Med. 1997;337:1524–1533. doi: 10.1056/NEJM199711203372107. [DOI] [PubMed] [Google Scholar]
- 18.Fraser D.W., Tsai T.R., Orenstein W. Legionnaires' disease: description of an epidemic of pneumonia. N Engl J Med. 1977;297:1189–1197. doi: 10.1056/NEJM197712012972201. [DOI] [PubMed] [Google Scholar]
- 19.Kamholz S.L. Resurgence of tuberculosis: the perspective a dozen years later. J Assoc Acad Minor Phys. 1996;7:83–86. [PubMed] [Google Scholar]
- 20.Cole E.C., Cook C.E. Characterization of infectious aerosols in health care facilities: an aid to effective engineering controls and preventive strategies. Am J Infect Control. 1998;26:453–464. doi: 10.1016/S0196-6553(98)70046-X. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 21.Roy C.J., Milton D.K. Airborne transmission of communicable infection – the elusive pathway. N Engl J Med. 2004;350:1710–1712. doi: 10.1056/NEJMp048051. [DOI] [PubMed] [Google Scholar]
- 22.Knibbs L.D., Morawska L., Bell S.C., Grzybowski P. Room ventilation and the risk of airborne infection transmission in 3 health care settings within a large teaching hospital. Am J Infect Control. 2011;39:866–872. doi: 10.1016/j.ajic.2011.02.014. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 23.Anonymous . The Stationary Office; Norwich: 2011. Tomorrow's healthcare environments – towards a sustainable future. 8758:0.7. [Google Scholar]
- 24.Beggs C.B., Kerr K.G., Noakes C.J., Hathway E.A., Sleigh P.A. The ventilation of multiple-bed hospital wards: review and analysis. Am J Infect Control. 2008;36:250–259. doi: 10.1016/j.ajic.2007.07.012. [DOI] [PubMed] [Google Scholar]
- 25.Shiomori T., Miyamoto H., Makishima K. Significance of airborne transmission of methicillin-resistant Staphylococcus aureus in an otolaryngology–head and neck surgery unit. Archs Otolaryngol Head Neck Surg. 2001;127:644–648. doi: 10.1001/archotol.127.6.644. [DOI] [PubMed] [Google Scholar]
- 26.Roberts K., Hathway E.A., Fletcher L.A., Beggs C.B., Elliott M.W., Sleigh P.A. Bioaerosol production on a respiratory ward. Indoor Built Environ. 2006;15:35–40. [Google Scholar]
- 27.Barker J., Stevens D., Bloomfield S.F. Spread and prevention of some common viral infections in community facilities and domestic homes. J Appl Microbiol. 2001;91:7–21. doi: 10.1046/j.1365-2672.2001.01364.x. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 28.Morawska L. Droplet fate in indoor environments, or can we prevent the spread of infection? Indoor Air. 2006;16:335–347. doi: 10.1111/j.1600-0668.2006.00432.x. [DOI] [PubMed] [Google Scholar]
- 29.Langmuir A.D. Epidemiology of airborne infection. Bacteriol Rev. 1961;25:173–181. doi: 10.1128/br.25.3.173-181.1961. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 30.Dimmick R.L., Akers A.B. Wiley InterScience; New York: 1969. An introduction to experimental aerobiology. [Google Scholar]
- 31.Weiss M.M., Weiss P.D., Weiss D.E., Weiss J.B. Disrupting the transmission of influenza A: face masks and ultraviolet light as control measures. Am J Public Health. 2007;97(Suppl. 1):S32–37. doi: 10.2105/AJPH.2006.096214. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 32.Wells W.F. On air-borne infection: study II. Droplets and droplet nuclei. Am J Hyg. 1934;20:611–618. [Google Scholar]
- 33.Lidwell O.M. Aerial dispersal of micro-organisms from the human respiratory tract. Soc Appl Bacteriol Symp Ser. 1974;3:135–154. [PubMed] [Google Scholar]
- 34.Beggs C.B. The airborne transmission of infection in hospital buildings: fact or fiction? Indoor Built Environ. 2003;12:9–18. [Google Scholar]
- 35.Loosli C.G. Dust and its control as a means of disinfection of air. Am J Public Health. 1947;37:353–358. [PubMed] [Google Scholar]
- 36.Weber T.P., Stilianakis N.I. Inactivation of influenza A viruses in the environment and modes of transmission: a critical review. J Infect. 2008;57:361–373. doi: 10.1016/j.jinf.2008.08.013. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 37.Tang J.W., Li Y., Eames I., Chan P.K., Ridgway G.L. Factors involved in the aerosol transmission of infection and control of ventilation in healthcare premises. J Hosp Infect. 2006;64:100–114. doi: 10.1016/j.jhin.2006.05.022. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 38.Tang J.W. The effect of environmental parameters on the survival of airborne infectious agents. J R Soc Interface. 2009;6(Suppl. 6):S737–S746. doi: 10.1098/rsif.2009.0227.focus. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 39.Nielsen P.V. Control of airborne infectious diseases in ventilated spaces. J R Soc Interface. 2009;6(Suppl. 6):S747–S755. doi: 10.1098/rsif.2009.0228.focus. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 40.Eames I., Shoaib D., Klettner C.A., Taban V. Movement of airborne contaminants in a hospital isolation room. J R Soc Interface. 2009;6(Suppl. 6):S757–S766. doi: 10.1098/rsif.2009.0319.focus. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 41.Clark R.P., de Calcina-Goff M.L. Some aspects of the airborne transmission of infection. J R Soc Interface. 2009;6(Suppl. 6):S767–S782. doi: 10.1098/rsif.2009.0236.focus. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 42.World Health Organization . 2004. Practical Guidelines for Infection Control in Health Care Facilities. SEARO Regional Publication No. 41, WPRO Regional Publication, India; [Google Scholar]
- 43.US Department of Health and Human Services, Centers for Disease Control and Prevention . CDC; Atlanta: 2003. Guidelines for environmental infection control in health-care facilities. [Google Scholar]
- 44.World Health Organization . WHO; Geneva, Switzerland: 2009. Pandemic Influenza Preparedness and Response. [PubMed] [Google Scholar]
- 45.Osterholm M.T. Preparing for the next pandemic. N Engl J Med. 2005;352:1839–1842. doi: 10.1056/NEJMp058068. [DOI] [PubMed] [Google Scholar]
- 46.Tang J.W., Li Y. Transmission of influenza A in human beings. Lancet Infect Dis. 2007;7:758. doi: 10.1016/S1473-3099(07)70268-2. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 47.Tellier R. Aerosol transmission of influenza A virus: a review of new studies. J R Soc Interface. 2009;6(Suppl. 6):S783–790. doi: 10.1098/rsif.2009.0302.focus. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 48.Moser M.R., Bender T.R., Margolis H.S., Noble G.R., Kendal A.P., Ritter D.G. An outbreak of influenza aboard a commercial airliner. Am J Epidemiol. 1979;110:1–5. doi: 10.1093/oxfordjournals.aje.a112781. [DOI] [PubMed] [Google Scholar]
- 49.Watanabe Y., Ibrahim M.S., Suzuki Y., Ikuta K. The changing nature of avian influenza A virus (H5N1) Trends Microbiol. 2012;20:11–20. doi: 10.1016/j.tim.2011.10.003. [DOI] [PubMed] [Google Scholar]
- 50.Gambotto A., Barratt-Boyes S.M., de Jong M.D., Neumann G., Kawaoka Y. Human infection with highly pathogenic H5N1 influenza virus. Lancet. 2008;371:1464–1475. doi: 10.1016/S0140-6736(08)60627-3. [DOI] [PubMed] [Google Scholar]
- 51.Aditama T.Y., Samaan G., Kusriastuti R. Avian Influenza H5N1 transmission in households, Indonesia. PLoS One. 2012;7:e29971. doi: 10.1371/journal.pone.0029971. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 52.Herfst S., Schrauwen E.J., Linster M. Airborne transmission of influenza A/H5N1 virus between ferrets. Science. 2012;336:1534–1541. doi: 10.1126/science.1213362. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 53.Langmuir L.D. Changing concepts of airborne infection of acute contagious diseases: a reconsideration of classic epidemiologic theories. Ann NY Acad Sci. 1980;353:35–44. doi: 10.1111/j.1749-6632.1980.tb18903.x. [DOI] [PubMed] [Google Scholar]
- 54.Wehrle P.F., Posch J., Richter K.H., Henderson D.A. An airborne outbreak of smallpox in a German hospital and its significance with respect to other recent outbreaks in Europe. Bull WHO. 1970;43:669–679. [PMC free article] [PubMed] [Google Scholar]
- 55.Zelicoff A.P. An epidemiological analysis of the 1971 smallpox outbreak in Aralsk, Kazakhstan. Crit Rev Microbiol. 2003;29:97–108. doi: 10.1080/713610418. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 56.Shooter R.A. H.M. Stationery Office; London: July 1980. Report of the investigation into the cause of the 1978 Birmingham smallpox occurrence. [Google Scholar]
- 57.Casanova L.M., Jeon S., Rutala W.A., Weber D.J., Sobsey M.D. Effects of air temperature and relative humidity coronavirus survival on surfaces. Appl Environ Microbiol. 2010;76:2712–2717. doi: 10.1128/AEM.02291-09. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 58.Chen W.Q., Ling W.H., Lu C.Y. Which preventive measures might protect health care workers from SARS? BMC Public Health. 2009;9:81. doi: 10.1186/1471-2458-9-81. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 59.Yu I.T., Li Y., Wong T.W., Tam W. Evidence of airborne transmission of the severe acute respiratory syndrome virus. N Engl J Med. 2004;350:1731–1739. doi: 10.1056/NEJMoa032867. [DOI] [PubMed] [Google Scholar]
- 60.McKinney K.R., Gong Y.Y., Lewis T.G. Environmental transmission of SARS at Amoy Gardens. J Environ Health. 2006;68:26–30. [PubMed] [Google Scholar]
- 61.Wong T.W., Lee C.K., Tam W. Cluster of SARS among medical students exposed to single patient, Hong Kong. Emerg Infect Dis. 2004;10:269–276. doi: 10.3201/eid1002.030452. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 62.Olsen S.J., Chang H.L., Cheung T.Y. Transmission of the severe acute respiratory syndrome on aircraft. N Engl J Med. 2003;349:2416–2422. doi: 10.1056/NEJMoa031349. [DOI] [PubMed] [Google Scholar]
- 63.Tong T.R. Airborne severe acute respiratory syndrome coronavirus and its implications. J Infect Dis. 2005;191:1401–1402. doi: 10.1086/429637. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 64.Kimmel M., Braun M., Alscher D.M. Should we recommend precautions during a hantavirus endemic? NDT Plus. 2010;3:424–426. doi: 10.1093/ndtplus/sfq093. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 65.Clement J., Maes P., Ducoffre G., Loock F.V., van Ranst M. Hantaviruses: underestimated respiratory viruses? Clin Infect Dis. 2008;46:477–479. doi: 10.1086/524896. [DOI] [PubMed] [Google Scholar]
- 66.Mills J.N., Corneli A., Young J.C., Garrison L.E., Khan A.S., Ksiazek T.G. Hantavirus pulmonary syndrome – United States: updated recommendations for risk reduction. Centers for Disease Control and Prevention. MMWR Recomm Rep. 2002;51(RR-9):1–12. [PubMed] [Google Scholar]
- 67.Widdowson M.A., Monroe S.S., Glass R.I. Are noroviruses emerging? Emerg Infect Dis. 2005;11:735–737. doi: 10.3201/eid1105.041090. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 68.Marshall J.A., Bruggink L.D. The dynamics of norovirus outbreak epidemics: recent insights. Int J Environ Res Public Health. 2011;8:1141–1149. doi: 10.3390/ijerph8041141. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 69.Greig J.D., Lee M.B. A review of nosocomial norovirus outbreaks: infection control interventions found effective. Epidemiol Infect. 2012;140:1151–1160. doi: 10.1017/S0950268811002731. [DOI] [PubMed] [Google Scholar]
- 70.Barker J., Jones M.V. The potential spread of infection caused by aerosol contamination of surfaces after flushing a domestic toilet. J Appl Microbiol. 2005;99:339–347. doi: 10.1111/j.1365-2672.2005.02610.x. [DOI] [PubMed] [Google Scholar]
- 71.Cunney R.J., Costigan P., McNamara E.B. Investigation of an outbreak of gastroenteritis caused by Norwalk-like virus, using solid phase immune electron microscopy. J Hosp Infect. 2000;44:113–118. doi: 10.1053/jhin.1999.0671. [DOI] [PubMed] [Google Scholar]
- 72.Nazaroff W.W. Norovirus, gastroenteritis, and indoor environmental quality. Indoor Air. 2011;21:353–356. doi: 10.1111/j.1600-0668.2011.00735.x. [DOI] [PubMed] [Google Scholar]
- 73.Monto A.S. Epidemiology of viral respiratory infections. Am J Med. 2002;112(Suppl 6A):4S–12S. doi: 10.1016/s0002-9343(01)01058-0. [DOI] [PubMed] [Google Scholar]
- 74.Jaakkola J.J., Heinonen O.P. Shared office space and the risk of the common cold. Eur J Epidemiol. 1995;11:213–216. doi: 10.1007/BF01719490. [DOI] [PubMed] [Google Scholar]
- 75.Myatt T.A., Johnston S.L., Zuo Z. Detection of airborne rhinovirus and its relation to outdoor air supply in office environments. Am J Respir Crit Care Med. 2004;169:1187–1190. doi: 10.1164/rccm.200306-760OC. [DOI] [PubMed] [Google Scholar]
- 76.Sun Y., Wang Z., Zhang Y., Sundell J. In China, students in crowded dormitories with a low ventilation rate have more common colds: evidence for airborne transmission. PLoS One. 2011;6:e27140. doi: 10.1371/journal.pone.0027140. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 77.Breese-Hall C. The nosocomial spread of respiratory syncytial virus infections. Ann Rev Med. 1983;34:311–319. doi: 10.1146/annurev.me.34.020183.001523. [DOI] [PubMed] [Google Scholar]
- 78.Mendell M.J., Fisk W.J., Kreiss K. Improving the health of workers in indoor environments: priority research needs for a national occupational research agenda. Am J Public Health. 2002;92:1430–1440. doi: 10.2105/ajph.92.9.1430. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 79.Fairchild A.L., Oppenheimer G.M. Public health nihilism vs pragmatism: history, politics, and the control of tuberculosis. Am J Public Health. 1998;88:1105–1117. doi: 10.2105/ajph.88.7.1105. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 80.Beggs C.B., Noakes C.J., Sleigh P.A. The transmission of tuberculosis in confined spaces: an analytical review of alternative epidemiological models. Int J Tuberc Lung Dis. 2003;7:1015–1026. [PubMed] [Google Scholar]
- 81.Larcombe L., Orr P. Housing conditions that serve as risk factors for tuberculosis infection and disease. An Advisory Committee Statement (ACS) Can Commun Dis Rep. 2007;33(ACS-9):1–13. [PubMed] [Google Scholar]
- 82.Kerr K. Controlling methicillin-resistant Staphylococcus aureus infection in hospitals. Eur Infect Dis. 2010;6:77–80. [Google Scholar]
- 83.Boyce J.M., Pittet D. Guideline for hand hygiene in health care settings: recommendations of the Healthcare Infection Control Practices Advisory Committee and the Hand Hygiene Task Force. Infect Control Hosp Epidemiol. 2003;23(Suppl.):1e40. doi: 10.1086/503164. [DOI] [PubMed] [Google Scholar]
- 84.Mortimer E.A., Jr., Wolinsky E., Gonzaga A.J., Rammelkamp C.H., Jr. Role of airborne transmission in staphylococcal infections. Br Med J. 1966;1:319–322. doi: 10.1136/bmj.1.5483.319. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 85.Sherertz R.J., Reagan D.R., Hampton K.D. A cloud adult: the Staphylococcus aureus–virus interaction revisited. Ann Intern Med. 1996;124:539–547. doi: 10.7326/0003-4819-124-6-199603150-00001. [DOI] [PubMed] [Google Scholar]
- 86.Williams R.E.O. Epidemiology of airborne staphylococcal infection. Bacteriol Rev. 1966;30:660–672. doi: 10.1128/br.30.3.660-674.1966. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 87.Lidwell O.M., Brock B., Shooter R.A., Cooke E.M., Thomas G.E. Airborne infection in a fully air-conditioned hospital. IV. Airborne dispersal of Staphylococcus aureus and its nasal acquisition by patients. J Hyg (Lond) 1975;75:445–474. doi: 10.1017/s0022172400024505. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 88.Shiomori T., Miyamoto H., Makishima K. Evaluation of bedmaking-related airborne and surface methicillin-resistant Staphylococcus aureus contamination. J Hosp Infect. 2002;50:30–35. doi: 10.1053/jhin.2001.1136. [DOI] [PubMed] [Google Scholar]
- 89.King M.F., Noakes C.J., Sleigh P.A., Carmago-Valero M.A. Bioaerosol deposition in single and two-bed hospital rooms: a numerical and experimental study. Build Environ. 2013;59:436–447. [Google Scholar]
- 90.Dansby W., Purdue G., Hunt J. Aerosolization of methicillin-resistant Staphylococcus aureus during an epidemic in a burn intensive care unit. J Burn Care Res. 2008;29:331–337. doi: 10.1097/BCR.0b013e3181667583. [DOI] [PubMed] [Google Scholar]
- 91.Rutala W.A., Katz E.B., Sherertz R.J., Sarubbi F.A., Jr. Environmental study of a methicillin-resistant Staphylococcus aureus epidemic in a burn unit. J Clin Microbiol. 1983;18:683–688. doi: 10.1128/jcm.18.3.683-688.1983. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 92.Farrington M., Ling J., Ling T., French G.L. Outbreaks of infection with methicillin-resistant Staphylococcus aureus on neonatal and burns units of a new hospital. Epidemiol Infect. 1990;105:215–228. doi: 10.1017/s0950268800047828. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 93.Cataldo M.A., Taglietti F., Petrosillo N. Methicillin-resistant Staphylococcus aureus: a community health threat. Postgrad Med J. 2010;122:16–23. doi: 10.3810/pgm.2010.11.2218. [DOI] [PubMed] [Google Scholar]
- 94.Allen K.D., Anson J.J., Parsons L.A., Frost N.G. Staff carriage of methicillin-resistant Staphylococcus aureus (EMRSA 15) and the home environment: a case report. J Hosp Infect. 1997;35:307–311. doi: 10.1016/s0195-6701(97)90225-5. [DOI] [PubMed] [Google Scholar]
- 95.Gandara A. Isolation of Staphylococcus aureus and antibiotic-resistant Staphylococcus aureus from residential indoor bioaerosols. Environ Health Perspect. 2006;114:1859–1864. doi: 10.1289/ehp.9585. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 96.Balm M.N., Jureen R., Teo C. Hot and steamy: outbreak of Bacillus cereus in Singapore associated with construction work and laundry practices. J Hosp Infect. 2012;81:224–230. doi: 10.1016/j.jhin.2012.04.022. [DOI] [PubMed] [Google Scholar]
- 97.Fournel I., Sautour M., Lafon I. Airborne aspergillus contamination during hospital construction works: efficacy of protective measures. Am J Infect Control. 2010;38:189–194. doi: 10.1016/j.ajic.2009.07.011. [DOI] [PubMed] [Google Scholar]
- 98.Wu M.J., Feng Y.S., Sung W.P., Surampalli R.Y. Quantification and analysis of airborne bacterial characteristics in a nursing care institution. J Air Waste Manag Assoc. 2011;61:732–739. doi: 10.3155/1047-3289.61.7.732. [DOI] [PubMed] [Google Scholar]
- 99.Bernards A.T., Frénay H.M., Lim B.T., Hendriks W.D., Dijkshoorn L., van Boven C.P. Methicillin-resistant Staphylococcus aureus and Acinetobacter baumannii: an unexpected difference in epidemiologic behavior. Am J Infect Control. 1998;26:544–551. doi: 10.1053/ic.1998.v26.a84555. [DOI] [PubMed] [Google Scholar]
- 100.Allen K.D., Green H.T. Hospital outbreak of multi-resistant Acinetobacter anitratus: an airborne mode of spread? J Hosp Infect. 1987;9:110–119. doi: 10.1016/0195-6701(87)90048-x. [DOI] [PubMed] [Google Scholar]
- 101.Panagea S., Winstanley C., Walshaw M.J., Ledson M.J., Hart C.A. Environmental contamination with an epidemic strain of Pseudomonas aeruginosa in a Liverpool cystic fibrosis centre, and study of its survival on dry surfaces. J Hosp Infect. 2005;59:102–107. doi: 10.1016/j.jhin.2004.09.018. [DOI] [PubMed] [Google Scholar]
- 102.Roberts K., Smith C.F., Snelling A.M. Aerial dissemination of Clostridium difficile spores. BMC Infect Dis. 2008;8:7. doi: 10.1186/1471-2334-8-7. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 103.Best E.L., Sandoe J.A., Wilcox M.H. Potential for aerosolization of Clostridium difficile after flushing toilets: the role of toilet lids in reducing environmental contamination risk. J Hosp Infect. 2012;80:1–5. doi: 10.1016/j.jhin.2011.08.010. [DOI] [PubMed] [Google Scholar]
- 104.Donskey C.J. Preventing transmission of Clostridium difficile: is the answer blowing in the wind? Clin Infect Dis. 2010;50:1458–1461. doi: 10.1086/652649. [DOI] [PubMed] [Google Scholar]
- 105.Hobday R.A., Cason J.W. The open-air treatment of pandemic influenza. Am J Public Health. 2009;99(Suppl. 2):S236–242. doi: 10.2105/AJPH.2008.134627. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 106.Ransome A., Delepine S. On the influence of certain natural agents on the virulence of the tubercle-bacillus. Proc R Soc Lond. 1894;56:51–56. [Google Scholar]
- 107.Hood A.M. Open-air factors in enclosed systems. J Hyg (Lond) 1974;72:53–60. doi: 10.1017/s0022172400023202. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 108.Cox C.S. The aerobiological pathway of microorganisms. John Wiley & Sons; Chichester: 1987. The open air factor; pp. 218–229. [Google Scholar]
- 109.Benbough J.E., Hood A.M. Viricidal activity of open air. J Hyg. 1971;69:619–626. doi: 10.1017/s0022172400021896. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 110.Hood A.M. The effect of open-air factors on the virulence and viability of airborne Francisella tularensis. Epidemiol Infect. 2009;137:753–761. doi: 10.1017/S0950268809002076. [DOI] [PubMed] [Google Scholar]
- 111.Wong V., Staniforth K., Boswell T. Environmental contamination and airborne microbial counts: a role for hydroxyl radical disinfection units? J Hosp Infect. 2011;78:194–199. doi: 10.1016/j.jhin.2011.03.003. [DOI] [PubMed] [Google Scholar]
- 112.Cox C.S., Hood A.M., Baxter J. Method for comparing concentrations of the open-air factor. Appl Microbiol. 1973;26:640–642. doi: 10.1128/am.26.4.640-642.1973. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 113.National Institute for Occupational Safety and Health . Department of Health and Human Services, Centers for Disease Control and Prevention, National Institute for Occupational Safety and Health; Cincinnati: May 2002. Guidance for protecting building environments from airborne chemical, biological, or radiological attacks. [Google Scholar]
- 114.Atkinson J., Chartier Y., Pessoa-Silva C.L., editors. Natural ventilation for infection control in health-care settings. World Health Organization; Geneva: 2009. [PubMed] [Google Scholar]
- 115.Bartley J.M., Olmsted R.N., Haas J. Current views of health care design and construction: practical implications for safer, cleaner environments. Am J Infect Control. 2010;38(Suppl. 1):S1–12. doi: 10.1016/j.ajic.2010.04.195. [DOI] [PubMed] [Google Scholar]
- 116.Phares C.R., Russell E., Thigpen M.C. Legionnaires’ disease among residents of a long-term care facility: the sentinel event in a community outbreak. Am J Infect Control. 2007;35:319–323. doi: 10.1016/j.ajic.2006.09.014. [DOI] [PubMed] [Google Scholar]
- 117.Kembel S.W., Jones E., Kline J. Architectural design influences the diversity and structure of the built environment microbiome. ISME J. 2012;6:1469–1479. doi: 10.1038/ismej.2011.211. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 118.Estates N.H.S. 2nd ed. NHS Estates; London: 1998. Health Technical Memorandum No 55. Windows. [Google Scholar]
- 119.Anonymous Influenza at the Camp Brooks open air hospital. JAMA. 1918;71:1746–1747. [Google Scholar]
- 120.Brooks W.A. The open air treatment of influenza. Am J Public Health. 1918;8:746–750. doi: 10.2105/ajph.8.10.746. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 121.Richards A.L., Hyams K.C., Watts D.M., Rozmajzl P.J., Woody J.N., Merrell B.R. Respiratory disease among military personnel in Saudi Arabia during Operation Desert Shield. Am J Public Health. 1993;83:1326–1329. doi: 10.2105/ajph.83.9.1326. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 122.Smylie H.G., Davidson A.I., Macdonald A., Smith G. Ward design in relation to postoperative wound infection. I. Br Med J. 1971;1(5740):67–72. doi: 10.1136/bmj.1.5740.67. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 123.Escombe A.R., Oeser C.C., Gilman R.H. Natural ventilation for the prevention of airborne contagion. PLoS Med. 2007;4:e68. doi: 10.1371/journal.pmed.0040068. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 124.Qian H., Li Y., Seto W.H., Ching P., Ching W.H., Sun H.Q. Natural ventilation for reducing airborne infection in hospitals. ISME J. 2010;45:559–565. doi: 10.1016/j.buildenv.2009.07.011. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 125.Jiang Y., Zhao B., Li X., Yang X., Zhang Z., Zhang Y. Investigating a safe ventilation rate for the prevention of indoor SARS transmission: an attempt based on simulation approach. Building Simulation. 2009;2:281–289. doi: 10.1007/s12273-009-9325-7. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 126.Jiang S., Huang L., Chen X. Ventilation of wards and nosocomial outbreak of severe acute respiratory syndrome among healthcare workers. Chin Med J. 2003;116:1293–1297. [PubMed] [Google Scholar]
- 127.Jiamjarasrangsi W., Bualert S., Chongthaleong A., Chaindamporn S., Udomsantisuk N., Euasamarnjit W. Inadequate ventilation for nosocomial tuberculosis prevention in public hospitals in Central Thailand. Int J Tuberc Lung Dis. 2009;13:454–459. [PubMed] [Google Scholar]
- 128.Lutz B.D., Jin J., Rinaldi M.G., Wickes B.L., Huycke M.M. Outbreak of invasive Aspergillus infection in surgical patients, associated with a contaminated air-handling system. Clin Infect Dis. 2003;37:786–793. doi: 10.1086/377537. [DOI] [PubMed] [Google Scholar]
- 129.McDonald L.C., Walker M., Carson L. Outbreak of Acinetobacter spp. bloodstream infections in a nursery associated with contaminated aerosols and air conditioners. Pediatr Infect Dis J. 1998;17:716–722. doi: 10.1097/00006454-199808000-00011. [DOI] [PubMed] [Google Scholar]
- 130.Uduman S.A., Farrukh A.S., Nath K.N. An outbreak of Serratia marcescens infection in a special-care baby unit of a community hospital in United Arab Emirates: the importance of the air conditioner duct as a nosocomial reservoir. J Hosp Infect. 2002;52:175–180. doi: 10.1053/jhin.2002.1308. [DOI] [PubMed] [Google Scholar]
- 131.Wagenvoort J.H., Davies B.I., Westermann E.J., Werink T.J., Toenbreker H.M. MRSA from air-exhaust channels. Lancet. 1993;341:840–841. doi: 10.1016/0140-6736(93)90626-r. [DOI] [PubMed] [Google Scholar]
- 132.Kumari D.N., Haji T.C., Keer V., Hawkey P.M., Duncanson V., Flower E. Ventilation grilles as a potential source of methicillin-resistant Staphylococcus aureus causing an outbreak in an orthopaedic ward at a district general hospital. J Hosp Infect. 1998;39:127–133. doi: 10.1016/s0195-6701(98)90326-7. [DOI] [PubMed] [Google Scholar]
- 133.Cotterill S., Evans R., Fraise A.P. An unusual source for an outbreak of methicillin-resistant Staphylococcus aureus. J Hosp Infect. 1996;32:207–216. doi: 10.1016/s0195-6701(96)90147-4. [DOI] [PubMed] [Google Scholar]
- 134.Brasche S., Bischof W. Daily time spent indoors in German homes – baseline data for the assessment of indoor exposure of German occupants. Int J Hyg Environ Health. 2005;208:247–253. doi: 10.1016/j.ijheh.2005.03.003. [DOI] [PubMed] [Google Scholar]
- 135.Leech J.A., Nelson W.C., Burnett R.T., Aaron S., Raizenne M.E. It’s about time: a comparison of Canadian and American time-activity patterns. J Expo Anal Environ Epidemiol. 2002;12:427–432. doi: 10.1038/sj.jea.7500244. [DOI] [PubMed] [Google Scholar]
- 136.Environmental Protection Agency. Report to Congress on Indoor Air Quality, Volume II: Assessment and Control of Indoor Air Pollution. Publication number EPA 400-1-89-001C. US Washington, DC: EPA; 1989. i, 4–14.
- 137.Sundell J. On the history of indoor air quality and health. Indoor Air. 2004;14(Suppl. 7):51–58. doi: 10.1111/j.1600-0668.2004.00273.x. [DOI] [PubMed] [Google Scholar]
- 138.Rintala H., Pitkäranta M., Toivola M., Paulin L., Nevalainen A. Diversity and seasonal dynamics of bacterial community in indoor environment. BMC Microbiol. 2008;8:56. doi: 10.1186/1471-2180-8-56. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 139.Balvers J., Bogers R., Jongeneel R., van Kamp I., Boerstra A., van Dijken F. Mechanical ventilation in recently built Dutch homes: technical shortcomings, possibilities for improvement, perceived indoor environment and health effects. Archs Sci Rev. 2012;55:4–14. [Google Scholar]
- 140.Downes A., Blunt T.P. Researches on the effect of light upon bacteria and other organisms. Proc R Soc. 1877;26:488–500. [Google Scholar]
- 141.Hockberger P.E. The discovery of the damaging effect of sunlight on bacteria. J Photochem Photobiol. 2000;58:185–191. doi: 10.1016/s1011-1344(00)00121-4. [DOI] [PubMed] [Google Scholar]
- 142.Solly S.E. Lea Brothers & Co.; Philadelphia and New York: 1897. A handbook of medical climatology. [Google Scholar]
- 143.Beckett H.E. HMSO; London: 1930. Ultra-violet window glazing. Building Research Bulletin No. 8. Department of Science and Industrial Research. [Google Scholar]
- 144.Broadhurst J., Hausmann T.W. Bacterial destruction through glass. Am J Nurs. 1930;30:1391–1394. [Google Scholar]
- 145.World Health Organization . WHO Regional Office for South-East Asia; New Delhi: January 2002. Guidelines on prevention and control of hospital associated infections. [Google Scholar]
- 146.Ranson R. Spon Press and the World Health Organization Regional Office for Europe; London: 1991. Healthy housing: a practical guide. [Google Scholar]
- 147.Rogers J.B. Studies on the viability of the tubercle bacillus. Am J Public Health (NY) 1920;10:345–347. doi: 10.2105/ajph.10.4.345. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 148.Smith C.R. Survival of tubercle bacilli. Am Rev Tuberc. 1942;45:334. [Google Scholar]
- 149.Garrod L.P. Some observations on hospital dust with special reference to light as a hygienic safeguard. Br Med J. 1944;1:245–247. doi: 10.1136/bmj.1.4337.245. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 150.Solowey M., Solotorovsky M., Buchbinder L. Studies on microorganisms in simulated room environments VII. Further observations on the survival rates of streptococci and pneumococci in daylight and darkness. J Bacteriol. 1942;42 doi: 10.1128/jb.43.5.545-555.1942. 545–555. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 151.Buchbinder L. The bactericidal effects of daylight and sunlight on chained Gram-positive cocci in simulated room environment: theoretical and practical considerations. In: Moulton F.R., editor. American Association for the Advancement of Science, Smithsonian Institute; Washington, DC: 1942. pp. 267–270. [Google Scholar]
- 152.Wood F.C. The viability of the pneumococcus after drying: a study of one of the factors in pneumonic infection. J Exp Med. 1905;7:592–625. doi: 10.1084/jem.7.5.592. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 153.Stillman E.G. Viability of pneumococci in dried sputum. J Infect Dis. 1938;63:340–345. [Google Scholar]
- 154.Williams S.G., Kauffman C.A. Survival of Streptococcus pneumoniae in sputum from patients with pneumonia. J Clin Microbiol. 1978;7:3–5. doi: 10.1128/jcm.7.1.3-5.1978. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 155.Miller C.P., Schad D. The resistance of meningococci to drying. J Bacteriol. 1944;47:71–77. doi: 10.1128/jb.47.1.71-77.1944. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 156.Miller C.P., Schad D. Germicidal action of daylight on meningococci in the dried state. J Bacteriol. 1944;47:79–84. doi: 10.1128/jb.47.1.79-84.1944. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 157.Chapple R.M., Inglis B., Stewart P.R. Lethal and mutational effects of solar and UV radiation on Staphylococcus aureus. Archs Microbiol. 1992;157:242–248. doi: 10.1007/BF00245157. [DOI] [PubMed] [Google Scholar]
- 158.el-Adhami W., Daly S., Stewart P.R. Biochemical studies on the lethal effects of solar and artificial ultraviolet radiation on Staphylococcus aureus. Arch Microbiol. 1994;161:82–87. doi: 10.1007/BF00248897. [DOI] [PubMed] [Google Scholar]
- 159.Buchbinder L., Solowey M., Phelps E.B. Studies on microorganisms in simulated room environments III. The survival rates in streptococci in the presence of natural daylight, sunlight and artificial illumination. J Bacteriol. 1941;42:353–366. doi: 10.1128/jb.42.3.353-366.1941. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 160.Lidwell O.M., Lowbury E.J. The survival of bacteria in dust: III. The effect of light on the survival of bacteria in dust. J Hyg (Lond) 1950;48:28–37. doi: 10.1017/s002217240001487x. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 161.Himmelfarb P., Scott A., Thayer P.S. Bactericidal activity of a broad-spectrum illumination source. Appl Microbiol. 1970;19:1013–1014. doi: 10.1128/am.19.6.1013-1014.1970. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 162.Kowalski W.J. Springer; Berlin: 2009. Ultraviolet germicidal irradiation handbook: UVGI for air and surface disinfection. [Google Scholar]
- 163.Maclean M., MacGregor S.J., Anderson J.G., Woolsey G.A. Inactivation of bacterial pathogens following exposure to light from a 405-nm LED array. Appl Environ Microbiol. 2009;75:1932–1937. doi: 10.1128/AEM.01892-08. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 164.Hamblin M.R., Viveros J., Yang C., Ahmadi A., Ganz R.A., Tolkoff M.J. Helicobacter pylori accumulates photoactive porphyrins and is killed by visible light. Antimicrob Agents Chemother. 2005;49:2822–2827. doi: 10.1128/AAC.49.7.2822-2827.2005. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 165.Maclean M., MacGregor S.J., Anderson J.G. Environmental decontamination of a hospital isolation room using high-intensity narrow-spectrum light. J Hosp Infect. 2011;76:247–251. doi: 10.1016/j.jhin.2010.07.010. [DOI] [PubMed] [Google Scholar]
- 166.Pail G., Huf W., Pjrek E. Bright-light therapy in the treatment of mood disorders. Neuropsychobiology. 2011;64:152–162. doi: 10.1159/000328950. [DOI] [PubMed] [Google Scholar]
- 167.Beauchemin K.M., Hayes P. Dying in the dark: sunshine, gender, and outcomes in myocardial infarction. J R Soc Med. 1998;91:352–354. doi: 10.1177/014107689809100703. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 168.Walch J.M., Rabin B.S., Day R., Williams J.N., Choi K., Kang J.D. The effect of sunlight on postoperative analgesic medication use: a prospective study of patients undergoing spinal surgery. Psychosom Med. 2005;67:156–163. doi: 10.1097/01.psy.0000149258.42508.70. [DOI] [PubMed] [Google Scholar]
- 169.Choi J.H., Beltran L.O., Kim H.S. Impacts of indoor daylight environments on patient average length of stay (ALOS) in a healthcare facility. Build Environ. 2012;50:65–75. [Google Scholar]
- 170.Riemersma-van der Lek R.F., Swaab D.F., Twisk J., Hol E.M., Hoogendijk W.J., Van Someren E.J. Effect of bright light and melatonin on cognitive and noncognitive function in elderly residents of group care facilities: a randomized controlled trial. JAMA. 2008;299:2642–2655. doi: 10.1001/jama.299.22.2642. [DOI] [PubMed] [Google Scholar]
- 171.Stevens R.G., Blask D.E., Brainard G.C. Meeting report: the role of environmental lighting and circadian disruption in cancer and other diseases. Environ Health Perspect. 2007;115:1357–1362. doi: 10.1289/ehp.10200. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 172.Silver A.C., Arjona A., Walker W.E., Fikrig E. The circadian clock controls toll-like receptor 9-mediated innate and adaptive immunity. Immunity. 2012;36:251–261. doi: 10.1016/j.immuni.2011.12.017. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 173.Butti K., Perlin J.K. Marion Boyars; London: 1980. A golden thread – 2500 years of solar architecture and technology. [Google Scholar]
- 174.Crinnion W.J. Sauna as a valuable clinical tool for cardiovascular, autoimmune, toxicant-induced and other chronic health problems. Altern Med Rev. 2011;16:215–225. [PubMed] [Google Scholar]
- 175.Danno K., Mori N., Toda K., Kobayashi T., Utani A. Near-infrared irradiation stimulates cutaneous wound repair: laboratory experiments on possible mechanisms. Photodermatol Photoimmunol Photomed. 2001;17:261–265. doi: 10.1034/j.1600-0781.2001.170603.x. [DOI] [PubMed] [Google Scholar]
- 176.Lewith G.T., Machin D. A randomised trial to evaluate the effect of infra-red stimulation of local trigger points, versus placebo, on the pain caused by cervical osteoarthrosis. Acupunct Electrother Res. 1981;6:277–284. doi: 10.3727/036012981816952180. [DOI] [PubMed] [Google Scholar]
- 177.Mercer J.B., Nielsen S.P., Hoffmann G. Improvement of wound healing by water-filtered infrared-A (wIRA) in patients with chronic venous stasis ulcers of the lower legs including evaluation using infrared thermography. Ger Med Science. 2008;6 Doc11. [PMC free article] [PubMed] [Google Scholar]
- 178.Postolache T.T., Hardin T.A., Myers F.S. Greater improvement in summer than with light treatment in winter in patients with seasonal affective disorder. Am J Psychiatry. 1998;155:1614–1616. doi: 10.1176/ajp.155.11.1614. [DOI] [PubMed] [Google Scholar]
- 179.Tsai J.F. Potential antidepressant effect of infrared irradiation has seasonality. Photomed Laser Surg. 2009;27:943–946. doi: 10.1089/pho.2008.2441. [DOI] [PubMed] [Google Scholar]
- 180.Lee S.Y., Seong I.W., Kim J.S. Enhancement of cutaneous immune response to bacterial infection after low-level light therapy with 1072nm infrared light: a preliminary study. J Photochem Photobiol. 2011;105:175–182. doi: 10.1016/j.jphotobiol.2011.08.009. [DOI] [PubMed] [Google Scholar]
- 181.Bornstein E., Hermans W., Gridley S., Manni J. Near-infrared photoinactivation of bacteria and fungi at physiologic temperatures. Photochem Photobiol. 2009;85:1364–1374. doi: 10.1111/j.1751-1097.2009.00615.x. [DOI] [PubMed] [Google Scholar]
- 182.Hess A.F., Unger L.J. The cure of infantile rickets by sunlight. J Am Med Assoc. 1921;77:39–41. [Google Scholar]
- 183.Ross J.R., Chant E., Tisdall F.F. Effect of sunshine through window glass and fresh air on resistance to infection. Am J Dis Childh. 1933;45:81–95. [Google Scholar]
- 184.Hewison M. Vitamin D and immune function: an overview. Proc Nutr Soc. 2012;71:50–61. doi: 10.1017/S0029665111001650. [DOI] [PubMed] [Google Scholar]
- 185.Atkinson W. J. Wiley & Sons; New York: 1912. The orientation of buildings or planning for sunlight. [Google Scholar]
- 186.Castro R., Angus D.C., Rosengart M.R. The effect of light on critical illness. Crit Care. 2011;15:218. doi: 10.1186/cc10000. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 187.Bernard M.C., Lanotte P., Lawrence C., Goudeau A., Bernard L. Air contamination around patients colonised with multidrug-resistant organisms. Infect Control Hosp Epidemiol. 2012;33:949–951. doi: 10.1086/667373. [DOI] [PubMed] [Google Scholar]
- 188.Fabian P., McDevitt J.J., DeHaan W.H. Influenza virus in human exhaled breath: an observational study. PLoS One. 2008;3:e2691. doi: 10.1371/journal.pone.0002691. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 189.Lytle C.D., Sagripanti J.L. Predicted inactivation of viruses of relevance to biodefense by solar radiation. J Virol. 2005;79:14244–14252. doi: 10.1128/JVI.79.22.14244-14252.2005. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 190.Bone A., Murray V., Myers I., Dengel A., Crump D. Will drivers for home energy-efficiency harm occupant health? Perspect Public Health. 2010;130:233–238. doi: 10.1177/1757913910369092. [DOI] [PubMed] [Google Scholar]
- 191.Hobday R.A. Historic Scotland; Edinburgh: 2011. Indoor environmental quality in refurbishment. Historic Scotland Research Report 12. [Google Scholar]
- 192.Goromosov M.S. World Health Organization; Geneva: 1968. The physiological basis of health standards for dwellings. Public Health Papers 33. [Google Scholar]
- 193.Hill L.E., Campbell A. Edward Arnold & Co.; London: 1925. Health and Environment. [Google Scholar]
- 194.Crump D., Dengel A., Swainson M. National House Building Council; Milton Keynes: 2009. Indoor air quality in highly energy-efficient homes – a review. NHBC Foundation Report NF18. [Google Scholar]