Hemodialysis-Associated Infections

Duc B Nguyen, Matthew J Arduino, Priti R Patel
PMCID: PMC7152337

Abstract

Hemodialysis patients are at increased risk of infections, which are common adverse events among this patient population. We review factors contributing to infections among hemodialysis patients and epidemiology of common infections and outbreaks, including bloodstream infections, vascular access infections, and infections caused by bloodborne pathogens. Recommendations for prevention are discussed with emphasis on essential infection control practices for hemodialysis settings.

Keywords: hemodialysis, infections, infection control

Introduction

Of the patients with end-stage renal disease (ESRD) treated by maintenance dialysis in the United States, approximately 90% are on maintenance hemodialysis and 10% are on peritoneal dialysis.1 Maintenance hemodialysis patients are at higher risk for infection, because uremia is known to make patients with ESRD more susceptible to infectious agents through defects in cellular immunity, neutrophil function, and complement activation.2, 3 In addition, because the process requires vascular access for long periods in an environment where multiple patients receive hemodialysis concurrently, repeated opportunities exist for transmission of infectious agents. Patient-to-patient transmission of infectious agents, directly or indirectly through contaminated devices, equipment, supplies, injectable medications, environmental surfaces, or hands of healthcare personnel have all been demonstrated. Furthermore, hemodialysis patients require frequent hospitalizations and surgery, which increases their opportunities for exposure and risk for developing healthcare-associated infections. This chapter describes (1) the major infectious diseases that can be acquired in the dialysis center setting, (2) important epidemiological and environmental microbiological considerations, and (3) infection control strategies.

Factors Contributing to Infections Among Hemodialysis Patients

Technical development and clinical use of hemodialysis delivery systems improved dramatically in the late 1960s and early 1970s. However, a number of microbiological parameters were not accounted for in the design of many hemodialysis machines and their respective water supply systems. There are many situations where certain types of gram-negative water bacteria can persist and actively multiply in hemodialysis water supplies and aqueous environments associated with hemodialysis equipment. This can result in massive numbers of gram-negative bacteria, which can directly or indirectly lead to septicemia or endotoxemia.4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17 These bacteria can adhere to surfaces and form biofilms (glycocalyces), which are virtually impossible to eradicate.6, 18, 19, 20 Control strategies are designed not to eradicate bacteria but to reduce their concentration to relatively low levels and to prevent their regrowth.

Although certain genera of gram-negative water bacteria (e.g., Burkholderia, Flavobacterium, Pseudomonas, Ralstonia, Serratia, Stenotrophomonas maltophilia, and Sphingomonas) are most commonly encountered, virtually any bacterium that can grow in water can be a problem in a hemodialysis unit. Several species of nontuberculous mycobacteria may also contaminate water treatment systems, including Mycobacterium chelonae, M. abscessus, M. fortuitum, M. gordonae, M. mucogenicum, M. scrofulaceum, M. kansasii, M. avium, and M. intracellulare; these microorganisms do not contain bacterial endotoxin but are comparatively resistant to chemical germicides.21, 22, 23, 24, 25, 26

Gram-negative water bacteria can multiply even in water containing relatively small amounts of organic matter, such as water treated by distillation, softening, deionization, or reverse osmosis, reaching levels of 105 to 107 microorganisms/mL6; these levels are not associated with visible turbidity. When treated water is mixed with dialysis concentrate, the resulting dialysis fluid is a balanced salt solution and growth medium almost as rich in nutrients as conventional nutrient broth.6, 27 Gram-negative water bacteria growing in dialysis fluids can reach levels of 108 to 109 microorganisms/mL, producing visible turbidity.

Bacterial growth in water used for hemodialysis depends on the types of water treatment system used, dialysate distribution systems, dialysis machine type, and method of disinfection (Table 25.1 ).6, 18, 21, 28, 29 Each component is discussed separately next.

TABLE 25.1.

Factors Influencing Microbial Contamination in Hemodialysis Systems


Factors
Comments
Water Supply (Water Source)
Groundwater Contains endotoxin and bacteria
Surface water Contains high levels of endotoxin, bacteria, and other organisms
Water Treatment at the Dialysis Center
None Not Recommended
Filtration
Prefilter Particulate filter to protect equipment; does not remove microorganisms
Absolute filter (depth or membrane) Removes bacteria but unless changed frequently or disinfected, bacteria will accumulate and grow through the filter; acts as a significant reservoir of bacteria and endotoxin
Granular activated carbon (GAC) Removes organics and available chlorine or chloramine; significant reservoir of water bacteria and endotoxin
Water Treatment Devices
Ion exchange (softener, deionization) Softeners and deionizers remove cations and anions, contaminants from source water; significant reservoir for bacteria and endotoxin
Reverse osmosis (RO) Removes bacteria, endotoxin, chemicals, and must be cleaned and disinfected; most systems employed for dialysis applications operate under high pressure
Ultraviolet (UV) germicidal irradiator Kills most bacteria, but there is no residual; some UV-resistant bacteria can develop
Ultrafilter Removes bacteria and endotoxin; operates on normal line pressure; can be positioned distal to storage tank and deionizer; must be disinfected or changed
Water and Dialysate Distribution System
Distribution pipes
Size Oversized diameters and length decrease fluid flow and increases bacterial reservoir in the form of biofilms for both treated water and central delivery systems (bicarbonate concentrate or bicarbonate dialysate)
Materials Pipe materials influence bacterial colonization and biofilm formation, as well as what types of chemical disinfectants can be used
Construction Rough joints, dead ends, and unused branches can act as bacterial reservoirs
Elevation Outlet taps should be located at highest elevation to prevent loss of disinfectant
Storage tanks Generally undesirable because of large surface area and can act as a reservoir for water bacteria; a properly designed tank can minimize this risk
Dialysis Machines
Single pass Disinfectant should have contact time with all parts of the machine that are in contact with treated water or dialysate
Recirculating single pass, or recirculating batch Recirculating pumps and machine design allow for massive contamination levels if not properly disinfected; overnight disinfection recommended

Microbial Contamination of Water

Water used for the production of dialysis fluid must be treated to remove chemical and microbial contaminants. The Association for the Advancement of Medical Instrumentation (AAMI) published guidelines and recommended practices for the chemical and microbial quality of water used to prepare dialysis fluid and reprocess hemodialyzers (Table 25.2 ).30, 31, 32, 33 The Centers for Medicare and Medicaid Services (CMS) has incorporated into their ESRD facility conditions for coverage infection control requirements that dialysis facilities need to follow, including water quality standards.34 Some components of the water treatment system may allow for amplification of water bacteria. For example, ion exchangers such as water softeners and deionizers do not remove endotoxin or microorganisms and provide many sites for significant bacterial multiplication.35 Granular activated carbon adsorption media (i.e., carbon filters) are used primarily to remove certain organic compounds and available chlorine (free and combined) from water, but they also significantly increase the level of water bacteria, yeast, fungi, and endotoxins.

TABLE 25.2.

AAMI Microbial Quality Standards for Dialysis Fluids31, 33


Microbial Bioburden
Endotoxin
Type of Fluid Maximum Contaminant Level Action Level Maximum Contaminant Level Action Level
Water for all purposes 100 CFU/mL 50 CFU/mL 0.25 EU/mL 0.125 EU/mL
Conventional dialysate 100 CFU/mL 50 CFU/mL 0.5 EU/mL 0.25 EU/mL
Ultrapure dialysate 1 CFU/10 mL 0.03 EU/mL
Dialysate for infusion This online process shall be validated by the manufacturer to produce fluid that is sterile and nonpyrogenic.

Compliance with a maximum bacterial level of 10–6 CFU/mL cannot be demonstrated by culturing, but by processes developed by the machine manufacturers.

A variety of filters are marketed to control bacterial contamination of water and dialysis fluids. Most are inadequate, especially if they are not routinely disinfected or frequently changed. Particulate filters, commonly called prefilters, operate by depth filtration and do not remove bacteria or endotoxin. These filters can become colonized with gram-negative water bacteria, resulting in higher levels of bacteria and endotoxin in the filter effluent. Absolute filters, including membrane types, temporarily remove bacteria from passing water. However, some of these filters tend to clog, and gram-negative water bacteria can “grow through” the filter matrix and colonize downstream surfaces of the filters within a few days. Further, absolute filters do not reduce levels of endotoxin in the effluent water. These filters should be changed regularly in accordance with the manufacturer’s directions and disinfected in the same manner and at the same time as the rest of the water distribution system.

Ultraviolet germicidal irradiation (UVGI) is sometimes used to reduce microbial contamination in water, but the use of UVGI has some special considerations. The lamp should be appropriately sized for the flow rate of water passing through the device, and the energy output should be monitored to ensure effectiveness of the lamp. Manufacturers of the lamp may require routine replacement schedule. Some bacterial populations may develop resistance to UVGI. In recirculating dialysis distribution systems, repeated exposure to UVGI are used to ensure adequate disinfection; however, this approach allows for progressive removal of sensitive microorganisms and selection of UVGI-resistant organisms. In addition, bacterial endotoxins are not affected.

Reverse osmosis (RO) is an effective water treatment modality that is used in more than 97% of US hemodialysis centers. RO possesses the singular advantage of being able to remove a variety of substances, including microorganisms and endotoxins, from supply water based primarily on particle size and adsorption to the membrane. However, low numbers of gram-negative and acid-fast organisms may penetrate the membrane or by other means (leaks around seals), and colonize downstream portions of the water distribution system. Consequently, the RO unit must be disinfected routinely.

We recommend a water treatment system that produces chemically adequate water while avoiding high levels of microbial contamination. The components in a typical water system should include (1) prefilters, (2) a water softener, (3) carbon adsorption tanks (at least two in series), (4) a particulate filter (to protect the reverse osmosis membrane), and (5) an RO unit. If one includes a deionization unit as a polisher (post–reverse osmosis unit) and a storage tank, the final component should be an ultrafilter to remove microorganisms and endotoxin. As the incoming tap water passes through the system components, it becomes more chemically pure, but the level of microbial contamination increases, which is why ultrafiltration and RO are important. Additional components or processes may be included in the pretreatment chain (see Table 25.1) depending on the pH, potable water disinfectant, and chemical quality of the incoming municipal water. If the system is adequately disinfected and properly maintained, the microbial content of water should be well within the recommended limits.

Distribution Systems

Water that has passed through the water distribution system (product water) is then distributed to individual dialysis machines where it is combined with dialysate concentrates and to a reprocessing area if a facility reprocesses hemodialyzers. It may also be combined with concentrates at a central location where the resulting dialysis fluid is supplied to the individual machines. Plastic pipe (most often polyvinyl chloride) is then used to distribute water, or dialysis fluids to the dialysis machines. Distribution systems should include the use of a loop-based system and no dead-ended pipes. Outlets to dialysis machines should have a relatively short path with the least amount of fittings and the use of valves with minimal dead space. Voids, dead ends, and large surface areas serve as sites for microbial colonization. Also large diameter pipes decrease fluid velocity and increase the wetted surface area available for microbial colonization. In addition, long pipe runs also increase the available surface area for colonization. Gram-negative water bacteria in fluids remaining in pipes overnight can rapidly multiply and colonize wetted surfaces of the distribution system, producing microbial populations and endotoxin in quantities proportional to the total volume of the surface area. Such colonization results in the formation of protective biofilm, which is difficult to remove and protects the bacteria and other organisms from disinfection.36 Continuous circulation of water slows down this process.37

Disinfection of the water or dialysate distribution system should be performed on a regular basis so that the microbial quality of the fluids is within the acceptable standards range. The frequency of disinfection should be validated by each facility and should be performed after any changes or modifications to the system.27, 38 AAMI standards and recommended practices are community consensus standards, and do not specify a schedule for disinfection other than to suggest that routine disinfection be conducted. In many instances, microbiological monitoring can be used to determine the frequency of testing of disinfection of the distribution system.38, 39 In some circumstances, repeat disinfection of the system cannot adequately control microbial growth because of established biofilm and replacement of the system is the only option.

To prevent disinfectant from draining from pipes by gravity before adequate contact time, distribution systems should be designed with all taps at equal elevation and at the highest point of the system. Furthermore, the system should be free of rough joints and dead-end pipes. Fluid trapped in such stagnant areas can serve as reservoirs for bacteria and fungi that later contaminate the rest of the distribution system.40

Storage tanks greatly increase the volume of fluid and surface area of the distribution system. If used, these should be designed with a conical bottom so that water exits the storage tank at its lowest point (and allows the tank to be drained), be fitted with a tight-sealing lid, be equipped with a spray head, and possess an air vent containing a bacteriological filter. If used, the storage tanks should be routinely cleaned, disinfected, and drained. To remove biofilm, use of strong oxidizers may aid in stripping biofilm from surfaces; however, physical scrubbing of the inner surfaces of the tank may be necessary. When using a storage tank, an ultrafilter should be incorporated before water is pumped into the distribution system.

Hemodialysis Machines, Effluent, and Environmental Surfaces

In the 1970s, most dialysis machines were of the recirculating or recirculating single-pass type; their design contributed to relatively high levels of gram-negative bacterial contamination in dialysis fluid. Virtually all dialysis machines in the United States now are single-pass machines (i.e., the dialysate flows through the machine once). Single-pass machines tend to respond to adequate cleaning and disinfection procedures and, in general, have lower levels of bacterial contamination than do recirculating machines. Levels of contamination in single-pass machines depend primarily on the microbiological quality of the incoming water and the method of machine disinfection.6, 38 Earlier dialysis machines had a port (waste-handling option) that allowed disposal of the extracorporeal circuit priming fluids. If one-way check valves in the waste-handling option are not maintained, checked for competency, or disinfected as recommended, it allows backflow from the effluent dialysate path into and contamination of the port and the attached bloodline. This led to outbreaks of infections among hemodialysis patients.41, 42, 43 The waste-handling option is much less commonly used now.

The external surfaces of dialysis machines and components are also likely sources for contamination. These include frequently touched surfaces (e.g., the control panel, dialysis chairs, keyboard, shared charting computers), attached priming buckets used during the priming of the dialyzers, blood tubing draped or clipped to waste containers, or other equipment brought into the station. For example, among nine outbreaks of bacteremia, fungemia, and pyrogenic reactions not related to dialyzer reuse investigated by the Centers for Disease Control and Prevention (CDC), inadequate disinfection of the water distribution system or dialysis machines was implicated in seven (Table 25.3 ).4, 9, 40, 41, 42, 43, 44, 45 Surface contamination has been described as a potential contributor to transmission of bloodborne pathogens in the context of other poor practices.46 A novel source of transmission has been identified: dialysis wall boxes, which contain several connections that allow the dialysis machine to hook up to the water supply and drain effluent. A large outbreak of bloodstream infections caused by Serratia marcescens, Pseudomonas aeruginosa, Enterobacter cloacae, and other gram-negative bacteria was identified and wall boxes were determined to be the source.47 More work is needed to understand the role of wall boxes and other surfaces and related infection control aspects in transmission of pathogens.

TABLE 25.3.

Outbreaks of Dialysis-Associated Illnesses Investigated by the Centers for Disease Control and Prevention, 1975–2016

Description Cause(s) of Outbreak Corrective Measure(s) Recommended Reference
Bacteremia, Fungemia, or Pyrogenic Reactions Not Related to Dialyzer Reuse
Pyrogenic reactions in 49 patients Untreated city water contained high levels of endotoxin Install a reverse osmosis system 4
Pyrogenic reactions in 45 patients Inadequate disinfection of the fluid distribution system Increase disinfection frequency and contact time 40
Pyrogenic reactions in 14 patients; 2 cases of bacteremia; 1 death Reverse osmosis water storage tank contaminated with bacteria Remove or properly maintain and disinfect the storage tank 28
Pyrogenic reactions in 6 patients; 7 cases of bacteremia Inadequate disinfection of water distribution system and dialysis machines; improper microbial assay procedure Use correct microbial assay procedures; disinfect water treatment system and dialysis machines following manufacturer’s recommended procedures 302
Bacteremia in 35 patients with central venous catheters (CVCs) CVCs used as facilities’ primary vascular access; median duration of infected catheters was 311 days; improper aseptic techniques Uses CVCs when only absolutely necessary for vascular access; use appropriate aseptic technique when inserting and performing routine catheter care 303
Three pyrogenic reactions and 10 cases of bacteremia in patients treated on machines with a port for disposal of dialyzer priming fluid (waste handling option [WHO] port) Incompetent check valves allowing backflow of fluid from the waste side of the machine into attached blood tubing; bacterial contamination of the WHO Routine disinfection and maintenance of the dialysis machine including the WHO; check competency of WHO before patient treatment 41
Bacteremia in 10 patients treated on machines with WHO port Incompetent backflow to allow backflow from dialysate effluent side of the machine in the WHO port and attached bloodlines Routine maintenance, disinfection, and check for check valve competence of the WHO port 42
Outbreak of pyrogenic reactions and gram-negative bacteremia in 11 patients Water distribution system and machines were not routinely disinfected according to manufacturer’s recommendations
Water and dialysate samples were cultured using a calibrated loop and blood agar plates—results always indicated no growth
Disinfect machines according to manufacturer’s recommendations; include reverse osmosis water distribution system in the weekly disinfection schedule; microbiological assay should be performed via membrane filtration or spread plate using Trypticase soy agar 9
Phialemonium curvatum access infections in four dialysis patients; two of these patients died of systemic disease Observations at the facility noted some irregularities in site preparation for needle insertion
All affected patients had synthetic grafts
One environmental sample was positive for P. curvatum (condensate pan of HVAC serving the unit)
Review infection control practices clean and disinfect HVAC system where water accumulated; perform surveillance on all patients 304
P. curvatum bloodstream infection (BSI) in two patients Water system and dialysis machines with WHO ports not routinely maintained; water system contained dead legs and laboratory used wrong assays Conduct routine maintenance and disinfection of machines and WHO ports; redesign water system to eliminate dead legs; have a routine schedule for disinfection of the water system 43
Outbreak of gram-negative BSI in 58 patients Poor infection control practices, contamination from dialysis wall boxes Improve infection control practices, cleaning and disinfection of wall boxes 47
Bacteremia/Pyrogenic Reactions Related to Dialyzer Reprocessing
Mycobacterial infections in 27 patients Inadequate concentration of dialyzer disinfectant Increase formaldehyde concentration used to disinfect dialyzers to 4% 22
Mycobacterial infections in five high-flux dialysis patients; two deaths Inadequate concentration of dialyzer disinfectant and inadequate disinfection of water treatment system Use higher concentration of peracetic acid for reprocessing dialyzers and follow manufacturer’s labeled recommendations; increase frequency of disinfecting the water treatment system 26
Bacteremia in six patients Inadequate concentration of dialyzer disinfectant; water used to reprocess dialyzers did not meet AAMI standards Use AAMI-quality water; ensure proper germicide concentration in the dialyzer CDC unpublished data
Bacteremia and pyrogenic reactions in six patients Dialyzer disinfectant diluted to improper concentration Use disinfectant at the manufacturer’s recommended dilution and verify concentration 60
Bacteremia and pyrogenic reactions in six patients Inadequate mixing of dialyzer disinfectant Thoroughly mix disinfectant and verify proper concentration 10
Bacteremia in 33 patients at 2 dialysis centers Dialyzer disinfectant created holes in the dialyzer membrane Change disinfectant (product was withdrawn from the market by the manufacturer) 305, 306
Bacteremia in six patients; all blood isolates had similar plasmid profiles Dialyzers were contaminated during removal and cleaning of headers with gauze; staff not routinely changing gloves; dialyzers not reprocessed for several hours after disassembly and cleaning Do not use gauze or similar material to remove clots from header; change gloves frequently; process dialyzers after rinsing and cleaning 59
Pyrogenic reactions in three high-flux dialysis patients Dialyzer reprocessed with two disinfectants; water for reuse did not meet AAMI standards Do not disinfect dialyzers with multiple germicides; more frequent disinfection of water treatment system and conduct routine environmental monitoring of water for reuse 307
Pyrogenic reactions in 14 high-flux dialysis patients; 1 death Dialyzers rinsed with city (tap) water containing high levels of endotoxin; water used to reprocess dialyzers did not meet AAMI standards Do not rinse or reprocess dialyzers with tap water; use AAMI-quality water for rinsing and preparing dialyzer disinfectant 308
Pyrogenic reactions in 18 patients Dialyzers rinsed with city (tap) water containing high levels of endotoxin; water used to reprocess dialyzers did not meet AAMI standards Do not rinse or reprocess dialyzers with tap water; use AAMI-quality water for rinsing and preparing dialyzer disinfectant 11
Pyrogenic reactions in 22 patients Water for reuse did not meet AAMI standards; improper microbiological technique was used on samples collected for monthly monitoring Use the recommended assay procedure for water analysis of water and dialysate; disinfect water distribution system 8
Bacteremia and candidemia among patients in seven dialysis units (in Minnesota and California) Dialyzers were not reprocessed in a timely manner; some dialyzer refrigerated for extended periods before reprocessing; company made changes to header cleaning protocol Reprocess dialyzers as soon as possible; follow joint CDC and dialyzer reprocessing equipment and disinfectant manufacturer guidance for cleaning and disinfecting headers of dialyzer CDC unpublished Data
Outbreak of gram-negative BSI, including Burkholderia cepacia and Stenotrophomonas maltophilia in 17 patients B. cepacia was isolated from header cleaning machine matched patient isolates
Contamination likely was due to incomplete disinfection during reprocessing
Reuse was stopped 52
Transmission of Viral Agents
26 patients seroconverted to HBsAg+ during a 10-month period Leakage of coil dialyzer membranes and use of recirculating bath dialysis machines Separation of HBsAg+ patients and equipment from all other patients 262
19 patients and 1 staff member seroconverted to HBsAg+ during a 14- month period No specific cause determined; false-positive HBsAg results caused some susceptible patients to be dialyzed with infected patients Laboratory confirmation of HBsAg+ results; strict adherence to glove use and use of separate equipment for HBsAg+ patients 309
24 patients and 6 staff seroconverted to HBsAg+ during a 10-month period Staff not wearing gloves; surfaces not properly disinfected; improper handling of needles/sharps resulting in many staff needlestick injuries Separation of HBsAg+ patients and equipment from susceptible patients; proper precautions by staff (e.g., gloves; handling of needles and sharps) 262
13 patients and 1 staff member seroconverted to HBsAg+ during a 1-month period Extrinsic contamination of intravenous medication being prepared adjacent to an area where blood samples were handled Separate medication preparation area from area where blood processing for diagnostic tests is performed 267
Eight patients seroconverted to HBsAg+ during a 5-month period Extrinsic contamination of multidose medication vial shared by HBsAg+ and HBsAg-susceptible patients No sharing of supplies, equipment, and medications between patients (CDC, unpublished data)
Seven patients seroconverted to HBsAg+ during a 3-month period Same staff caring for HBsAg+ and HBsAg-susceptible patients Separation of HBsAg+ patients from other patients; same staff should not care for HBsAg+ and HBsAg– patients 264
Eight patients seroconverted to HBsAg+ during a 1-month period Not consistently using external pressure transducer protectors; same staff members cared for both HBsAg+ patients and susceptible patients Use external pressure transducer protectors and replace after each use; same staff members should not care for HBV-infected and -susceptible patients on the same shift 310
14 patients seroconverted to HBsAg+ during a 6-week period Failure to review results of admission and monthly HBsAg testing; inconsistent handwashing and use of gloves; adjacent clean and contaminated areas; <20% of patients vaccinated Proper infection control precautions for dialysis facilities; routine review of serological testing; hepatitis B vaccination of all patients 265
Seven patients on the same shift seroconverted to HBsAg+ during a 2-month period Same staff members cared for HBsAg+ and HBsAg– patients on the same shift; common medication and supply carts were moved between stations, and multidose vials were shared Dedicated staff for HBsAg+ patients; no sharing of equipment or supplies between any patients; centralized medication and supply areas; hepatitis B vaccination of all patients 265
Four patients seroconverted HBsAg+ during a 3-month period Transmission appeared to occur during hospitalization at an acute care facility Hepatitis B vaccination of all patients 265
11 patients seroconverted to HBsAg+ during a 3-month period Staff, equipment, and supplies were shared between HBsAg+ and HBs– patients; no patients were vaccinated Dedicated staff for HBsAg+; no sharing of medication or supplies between any patients; hepatitis B vaccination of all patients 265
Two patients converted to HBsAg+ during a 4-month period Transmission appeared to occur during hospitalization at an acute care facility; Same staff cared for HBsAg+ and HBs– patients; no patients vaccinated Hepatitis B vaccination of all patients; dedicate staff for the care of HBsAg+ patients; no sharing of supplies or medication between patients 268
One patient converted to HBsAg+ Transmission from a patient with history of resolved HBV infection, but the infection reactivated as a result of immunosuppression; multiple infection control breaches observed Awareness of the reactivation/reserve seroconversion situation 271
36 patients with liver enzyme elevations consistent with non-A, non-B hepatitis Environmental contamination with blood Use proper precautions (e.g., gloving of staff; environmental cleaning); monthly liver function tests (e.g., ALT) 311
35 patients developed elevated liver enzymes consistent with non-A, non-B hepatitis during a 22-month period; 82% of probable cases were anti-HCV+ Inconsistent use of infection control precautions, especially hand washing Strict compliance to aseptic technique and dialysis center precautions 312
HCV infection developed in 7 out of 40 (17.5%) HCV-susceptible patients; shift specific attack rates of 29%–36% Multidose vials left on top of machine and used by multiple patients; routine cleaning and disinfection of surfaces and equipment between patients not routinely done; arterial line for draining prime draped into a bucket that was not routinely cleaned or disinfected between patients Strict compliance with infection control precautions for all dialysis patients; routine HCV testing 239, 241
HCV infection developed in 5 out of 61 (8%) HCV-susceptible patients Sharing of equipment and supplies between chronically infected and susceptible patients; gloves not routinely used; clean and contaminated areas not separated Strict compliance with infection control precautions for all dialysis patients; CDC does not recommend separation of equipment/supplies between HCV-infected and -susceptible patients 239, 241
HCV infection developed in 3 out of 23 (13%) HCV- susceptible patients Supply carts moved between stations and contained both clean and blood-contaminated items; medications prepared in the same area used for disposal of used injection equipment Strict compliance with infection control precautions for all dialysis patients 241
HCV infection developed in 7 out of 52 (13%) HCV-susceptible patients; shift-specific attack rates 4%–21% Medication cart moved between stations and contained both clean and blood-contaminated items; single-dose medication vials used for multiple patients; cleaning and disinfection of surfaces and equipment between patients not routinely done Strict compliance with infection control precautions for all dialysis patients 241
HCV infection developed in 9 out of 119 (7.6%) patients; attack rate 10% Cleaning and disinfection of surfaces and equipment between patients not routinely done; gloves not routinely used; medications not stored in separate clean area Strict compliance with infection control precautions for all dialysis patients; perform routine HCV testing 227
HCV infections developed in 6 out of 66 (9%) patients Clean and contaminated areas not well delineated; clean supplies accessed with contaminated gloves; medication preparation in proximity to blood specimen processing; reuse of single-dose vial Strict compliance with infection control precautions for all dialysis patients CDC unpublished data
HCV infections developed in 8 out of 149 (5.4%) patients; attack rate 8.6% Multidose heparin vials taken to individual dialysis stations; poor hand hygiene and glove use; poor cleaning and disinfection practices Strict compliance with infection control precautions for all dialysis patients 244
HCV infections developed in 18 patients; attack rate 16.7% Poor hand hygiene and glove use; poor cleaning and disinfection practices; blood stains found on machine surfaces after cleaning Strict compliance with infection control precautions for all dialysis patients 46
HCV infections developed in 16 patients at 9 facilities between 2013 and 2015 Multiple infection control breaches identified Strict compliance with infection control precautions for all dialysis patients 313

ALT, Alanine aminotransferase; HBsAg, hepatitis B surface antigen; HVAC, heating, ventilation, and air conditioning.

Updates on HBV and HCV outbreaks among dialysis patients reported to CDC are available at https://www.cdc.gov/hepatitis/outbreaks/healthcarehepoutbreaktable.htm.

Hemodialyzer Reuse

Reuse of disposable hollow-fiber dialyzers in the United States increased between 1976 and 1982, from 18% to 43% of facilities reporting reuse; the highest percentage was 82% in 1997.48 By 2002 the percentage of facilities reporting reusing dialyzers had declined to 63%.49 Recent data from the CDC’s National Healthcare Safety Network indicated that only 1.8% of facilities reported reuse in 2017 (CDC, unpublished data). This decline coincides with decisions made by several large dialysis organizations to discontinue the practice of reuse and to only use single-use dialyzers. Although dialyzer reuse is still common in developing countries, it has become less popular in developed countries and some have plans to phase out this practice.50, 51 After a series of outbreaks of bacterial infections associated with reuse and reprocessing of dialyzers, CDC recommended that single use of dialyzers be the preferred practice and stated that it should be used whenever possible.52

In 1986, AAMI standards for reprocessing hemodialyzers53 were adopted by the United States Public Health Service and was incorporated into regulation by CMS. In the United States, dialyzer reuse has not been associated with the transmission of bloodborne pathogens such as hepatitis B (HBV), hepatitis C (HCV), or human immunodeficiency virus (HIV).54, 55 However, the reprocessing of dialyzers has been associated with pyrogenic reactions and bacterial infections.54 These adverse events may be the result of the use of incorrect concentrations of chemical germicides, the failure to maintain appropriate water quality, breaks in reprocessing procedures, or practical challenges to achieving complete disinfection of reused dialyzers. Manual reprocessing of dialyzers, which is allowed in the United States, does not include testing for membrane integrity, such as a pressure-leak test, may fail to detect membrane defects, and relies on disinfection processes that are particularly difficult to standardize.54, 55

Dialyzer reprocessing can be performed in myriad ways with few quality control checks.52 Procedures used to reprocess hemodialyzers generally constitute high-level disinfection rather than sterilization.20, 56 Several liquid chemical germicides have been used for high-level disinfection of dialyzers. There are commercially available chemical germicides specifically formulated for this purpose (e.g., peroxyacetic acid, chlorine-based, and glutaraldehyde-based products that are approved by the US Food and Drug Administration [FDA] as sterilants or high-level disinfectants for reprocessing hemodialyzers). During the period between 1983 and 2002, the percentage of centers using formaldehyde for reprocessing dialyzers decreased from 94% to 20%, whereas the percentage using peroxyacetic acid increased from 5% to 72%. Only a minority of facilities (4%) reported used either glutaraldehyde or heat disinfection.49

Using a suboptimal disinfectant may lead to outbreaks of infection, such as nontuberculous mycobacteria.20, 22, 54, 56 An outbreak of systemic mycobacterial infections in five hemodialysis patients, resulting in two deaths, occurred when high-flux dialyzers were contaminated with Mycobacterium abscessus during manual reprocessing and disinfected with a commercial disinfectant prepared at a concentration that did not ensure complete inactivation of mycobacteria.26 These and other outbreaks of infections in dialysis patients emphasize the need to reconsider the safety and necessity of dialyzer reuse.

Outbreaks of pyrogenic reactions (defined as fever or chills in a patient who was afebrile and had no signs or symptoms of an infection before the start of the dialysis treatment session) have often resulted from reprocessing hemodialyzers with water that did not meet AAMI standards (see Table 25.3). In most instances the water used to rinse dialyzers or to prepare the dialyzer disinfectants exceeded the allowable AAMI microbial or endotoxin standards, because the water distribution system was not disinfected frequently, the disinfectant was improperly prepared, or routine microbial assays were improperly performed. Several outbreaks associated with dialyzer reuse have been reported. Breaches in disinfection of dialyzer components (such as an O-ring) and contamination caused by poor infection control practices during reprocessing steps have been identified as major contributors to those outbreaks.52, 57, 58, 59 In at least one outbreak, no major breaches in reprocessing were identified. Rather, it was determined that dialyzers are difficult to reprocess safely and completely under typical conditions. This is due to poorly trained staff (often in low-paying jobs), variability in procedures, and few quality control standards.52

As described in the most recent investigation of a reuse associated outbreak that resulted in 17 cases, “In practice, reuse and reprocessing of dialyzers poses an increased risk for infection to patients.”52 In this investigation, each additional use of a dialyzer was associated with higher odds of bloodstream infection. In the era of affordable single-use dialyzers, dialysis providers have discontinued reuse in the interest of patient safety.52 For facilities or regions where reuse and reprocessing continues to be performed, improved standardization of processes and rigorous quality assurance programs are needed.

High-Flux Dialysis and Bicarbonate Dialysate

High-flux dialysis uses dialyzer membranes and hydraulic permeability that are 5 to 10 times greater than conventional dialyzer membranes. There has been concern that bacteria or more likely endotoxin in the dialysate may penetrate these highly permeable membranes.

High-flux membranes require the use of bicarbonate rather than acetate dialysate. Bicarbonate dialysate must be prepared from two concentrates, an acid concentrate (acetic acid or citric acid) with a pH of 2.8 that is not conducive to microbial growth and a bicarbonate concentrate with a relatively neutral pH and a salt molarity of 1.2 M. Because the bicarbonate concentrate will support rapid growth,60 its use can increase microbial and endotoxin concentrations in the dialysate and theoretically may contribute to an increase in pyrogenic reactions, especially when used during high-flux dialysis.

Some of the concern appeared justified by results of surveillance data during the 1990s showing a significant association between use of high-flux dialysis and reporting of pyrogenic reactions among patients during dialysis.61 However, a prospective study of pyrogenic reactions in patients receiving more than 27,000 conventional, high-efficiency, or high-flux dialysis with bicarbonate dialysate containing high concentrations of bacteria and endotoxin found no association between pyrogenic reactions and the type of dialysis treatment.5 Although there seems to be conflicting data on the relationship between high-flux dialysis and pyrogenic reactions, centers providing high-flux dialysis should ensure that dialysate meets AAMI microbial standards (see Table 25.2).

Disinfection of Hemodialysis Systems

Routine disinfection of isolated components of the dialysis system often produces inadequate results. Consequently, the total dialysis system (water treatment system, distribution system, and dialysis machine) should be included in the disinfection procedure.

Disinfection of dialysis systems usually employs sodium hypochlorite solutions, hydrogen peroxide solutions, commercially available peracetic acid disinfectants, ozone, and, in some systems, hot water pasteurization. Sodium hypochlorite solutions are convenient and effective in most parts of the dialysis system when used at the manufacturer’s recommended concentrations. Also, the test for residual available chlorine to confirm adequate rinsing is simple and sensitive. However, because chlorine is corrosive, it is usually rinsed from the system after a relatively short dwell time of 20 to 30 minutes. The rinse water invariably contains organisms that can multiply to significant levels if the system is permitted to stand overnight.27 Therefore disinfection with chlorine-based disinfectants are best used before the start of the first patient treatment session rather than at the end of the day. However, for models of machines that most dialysis facilities are using, options for disinfection include heat at the end of the day and use of other disinfectants with longer contact time that also require overnight dwell. There is no need to disinfect the fluid pathway between patients.

Aqueous formaldehyde, peroxyacetic acid, hydrogen peroxide, or glutaraldehyde solutions can produce good disinfection results.18, 62, 63 These products are not as corrosive as hypochlorite solutions and can be allowed to dwell in the system for long periods of time when the system is not in operation. However, formaldehyde, which has good penetrating power, is considered an environmental hazard and potential carcinogen and has irritating qualities that may be objectionable to staff.64 The US Environmental Protection Agency has also limited the amount of formaldehyde that can be discharged into the wastewater stream, which has drastically reduced the use of this chemical in the dialysis community as a disinfectant. Peroxyacetic acid and glutaraldehyde are commercially available and are designed for use with dialysis machines when used according to the manufacturers labeled instructions. Glutaraldehyde use is also limited because it is considered a sensitizer and may pose a risk to healthcare workers.

Some dialysis systems (both water treatment and distribution systems, some hemodialysis machines) use hot-water disinfection (pasteurization) for control of microbial contamination. In this type of system water heated to >80°C (176°F) is passed through the water distribution system and hemodialysis machine or just the hemodialysis machine at the end of the day. These systems are excellent for controlling microbial contamination. However, it should be noted that heat disinfection of the hemodialysis machine would not control microbial contamination of the waste lines and effluent drains. Additional processes may be needed to disinfect waste lines, drains, and wall boxes.

Monitoring of Water and Dialysis Fluid

Microbiological and endotoxin standards for water and dialysis fluids (see Table 25.2)30, 39, 65, 66, 67 were originally based on the results of culture assays performed during outbreak investigations. There is increasing evidence that the microbial quality of hemodialysis fluids plays a role in the chronic inflammatory response syndrome, affects anemia management, accelerates loss of residual renal function, and affects serum albumin levels in dialysis patients.68, 69, 70, 71, 72, 73, 74, 75, 76, 77, 78, 79, 80, 81, 82 Increasing data suggest that use of ultrapure water and dialysate would benefit maintenance hemodialysis patients and potentially save costs.83, 84 A large cohort study from Japan found a lower all-cause mortality in facilities using ultrapure water.85 However, there have been no randomized controlled studies to evaluate and confirm these studies, so regulatory agencies have not yet mandated these higher water standards.83

Water samples for routine testing should be collected from a source as close as possible to where water enters the dialysate proportioning unit. In most cases this is the tap (not from that hose connecting the tap to the dialysis machine) at the dialysis station (Fig. 25.1 ). Water samples should be collected at least monthly from several locations within the dialysis unit, including samples at different dialysis stations. Samples should also be collected using a similar approach after any modifications or maintenance have been made to the water treatment system water distribution system. Dialysate samples should be collected during or at the end of the dialysis treatment from a source close to where the dialysis fluid either enters or leaves the dialyzer (Fig. 25.2 ). Dialysate samples should be collected at least monthly from a representative number of dialysis machines. Samples of water and dialysate should also be collected when a pyrogenic reaction is suspected. If centers reprocess hemodialyzers for reuse, water used to prepare disinfectant and rinse dialyzers should also be assayed monthly.30, 66 The maximum contaminant levels for water are 100 CFU/mL and 0.25 EU/mL (see Table 25.2).30, 31, 33 Methods for microbiological and endotoxin testing are available elsewhere.86

FIG. 25.1.

FIG. 25.1

Example of sources to sample water. (A) Connection on water distribution loop, with added adapter to facilitate water sampling. (B) Water connection inside wall box, where water sample can be taken.

Photos courtesy Stephanie Booth.

FIG. 25.2.

FIG. 25.2

Examples of sources to sample dialysate. (A) Dialyzer port. (B) Hansen connector ports.

Photos courtesy Stephanie Booth.

In an outbreak investigation, the assay methods may need to be both qualitative and quantitative; also detection of nontuberculous mycobacteria and in some cases fungi in water or dialysate may be desirable. In such instances, plates should be incubated for 5 to 14 days at both 36°C and 28° to 30°C. Laboratories should be notified of special testing requests outside of routine water testing, such as if the facilities would like to look for specific pathogens.

Dialysis-Associated Pyrogenic Reactions

Gram-negative bacterial contamination of dialysis water or components of the dialysis system (water, dialysate, water used for reprocessing) can cause pyrogenic reactions. A pyrogenic reaction is defined as objective chills (visible rigors) or fever (oral temperature ≥ 37.8°C [100°F]) or both in a patient who was afebrile (oral temperature up to 37°C [98.6°F]) and had no signs or symptoms of an infection before the start of the dialysis treatment session.87, 88 Depending on the type of dialysis system and the level of contamination, fever and chills may start 1 to 5 hours after dialysis has been initiated. Other symptoms may include hypotension, headache, myalgia, nausea, and vomiting. Pyrogenic reactions can occur without bacteria; because presenting signs and symptoms cannot differentiate bacteremia from pyrogenic reactions, blood cultures are necessary.

During 1990–2002 an annual average of 20% to 24% of the hemodialysis centers in the United States reported at least one pyrogenic reaction in the absence of septicemia in their patients undergoing maintenance hemodialysis.48, 49, 89, 90, 91, 92, 93, 94, 95, 96, 97 Pyrogenic reactions can result from passage of bacterial endotoxin (lipopolysaccharide) or other substances in the dialysate across the dialyzer membrane98, 99, 100, 101, 102 or from the transmembrane stimulation of cytokine production in the patient’s blood by endotoxin in the dialysate.99, 103, 104, 105 In other instances, endotoxin can enter directly into the bloodstream with fluids that are contaminated with gram-negative bacteria.106 The signs and symptoms of pyrogenic reactions without bacteremia generally abate within a few hours after the dialysis has been stopped. If gram-negative sepsis is associated, fever and chills may persist and hypotension is more refractory to therapy.4, 106

When a patient develops a pyrogenic reaction (i.e., onset of fever or chills) while being dialyzed, the following steps are recommended: (1) careful physical examination of the patient to identify signs and symptoms and evaluate other possible causes of chills and fever (e.g., pneumonia, vascular access site infection); (2) blood cultures, other diagnostic tests (e.g., chest radiograph), and other cultures as clinically indicated; (3) collection of dialysate from the dialyzer (i.e., postdialyzer effluent sample) for quantitative and qualitative microbiological culture; and (4) recording of the incident in a log or other permanent record. In addition, empiric antibiotic treatment should be administered to the patient. Determining the cause of such episodes is important because they may be the first indication of a remediable problem that can affect a potentially large number of patients.

The higher the level of bacteria and endotoxin in dialysis fluid, the higher the probability that the bacteria or their products will pass through the dialyzer membrane to produce bacteremia or stimulate cytokine production. In an outbreak of febrile reactions among patients undergoing hemodialysis, the attack rates were directly proportional to the level of microbial contamination in the dialysis fluid.6 Prospective studies also reported a lower pyrogenic reaction rate among patients when they underwent dialysis with dialysis fluid from which most bacteria had been removed by filtration, compared with patients who underwent dialysis fluid that was highly contaminated (mean 19,000 CFU/mL).5, 87, 107

Disinfection, Sterilization, and Environmental Cleaning in Dialysis Facilities

Good cleaning, disinfection, and sterilization procedures are important components of the infection control program in the hemodialysis center. The procedures do not differ from those recommended for other healthcare settings,108, 109 but the high potential for blood contamination makes the hemodialysis setting unique. In addition, the need for routine aseptic access of the patient’s vascular system makes the hemodialysis unit more akin to a surgical suite than to a standard hospital room. Medical items are categorized as critical (e.g., needles and catheters), which are introduced directly into the bloodstream or normally sterile areas of the body; semicritical (e.g., fiberoptic endoscopes), which come in contact with intact mucous membranes; and noncritical (e.g., blood pressure cuffs), which touch only intact skin.109, 110

Cleaning and housekeeping in the dialysis center have two goals: to remove soil and waste on a regular basis, thereby preventing the accumulation of potentially infectious material, and to maintain an environment that is conducive to good patient care.110 Crowding of patients and patient stations, as well as overtaxing of staff members, may increase the likelihood of microbial transmission. Adequate cleaning may be difficult if there are multiple wires, tubes, and hoses in a small area. There should be enough space to move completely around each patient’s dialysis station without interfering with the neighboring stations. According to the Facility Guidelines Institute, each dialysis station should be at least 80 square feet and allow at least 4 feet distance between stations to avoid contamination.111 However, most of dialysis facilities do not have space to meet that guideline. To avoid contamination, cleaning should only start when patients have left the station and staff should not allow new patients into chairs until cleaning and disinfection is complete. Creating unit-wide patient-free intervals between treatment shifts is likely to improve the adequacy of station cleaning and disinfection between patients.

Where space is limited, elimination of unneeded items, orderly arrangement of required items and removal of excess lengths of tubes, hoses, and wires from the floor can improve accessibility for cleaning. Because of the special requirements for cleaning in the dialysis center, staff should be specially trained in this task.

After each patient treatment, frequently touched environmental surfaces, including external surfaces of the dialysis machine, should be properly disinfected; some surfaces may also require precleaning (with a detergent) before disinfection. A study in the Netherlands and an investigation of a large HCV outbreak in the United States where the investigators used chemiluminescent agents to detect nonvisible blood contamination have demonstrated the importance of environmental cleaning.46, 112 Antiseptics, such as formulations with povidone-iodine, hexachlorophene, or chlorhexidine, should not be used for surface disinfection because these are formulated for use on skin and are not designed for use on hard surfaces. Given the role of environmental surfaces of components adjacent to the machine (e.g., wall boxes) in transmission of pathogens, as illustrated in recent outbreak,47 attention should be paid to cleaning and disinfection of those surfaces as well.

Bloodstream Infections and Other Infections

The annual adjusted mortality rate among hemodialysis patients is 169 per thousand patient-years at risk. Infection is the second leading cause of mortality in this patient population, accounting for 8% of all deaths.1 In a number of published studies that have evaluated bacterial infections in outpatient hemodialysis, bacteremia occurred in 0.6% to 1.7% of patients per month and vascular access infections (VAIs; with or without bacteremia) in 1.3% to 7.2% of patients per month.113, 114, 115, 116, 117, 118, 119, 120, 121, 122, 123 A review of four studies published during 2002 estimated that 1.8% of hemodialysis patients have vascular access associated bacteremia each month, amounting to 50,000 episodes nationally per year.124 In a study of 27 French hemodialysis centers, 28% of 230 infections in hemodialysis patients involved the vascular access, whereas 25% involved the lung, 23% the urinary tract, 9% the skin and soft tissues, and 15% other or unknown sites.119

Because of the importance of bacterial infections in hemodialysis patients, the CDC initiated a voluntary ongoing surveillance system in the United States called the Dialysis Surveillance Network (DSN) in 1999.122 At the time, only bacterial infections associated with hospital admission or intravenous antimicrobial receipt were counted; as a result, this system likely only detected more severe infections. During 1999–2001, 109 dialysis centers reported data. Rates per 100 patient-months were 3.2 for all VAIs (including access infections both with and without bacteremia), 1.8 for vascular access associated bacteremia, 1.3 for wound infection not related to the vascular access, 0.8 for pneumonia, and 0.3 for urinary tract infection. Among patients with fistulas or grafts, wounds were the most common site for infection. Among patients with hemodialysis catheters, infections of the vascular access site were the most common site for infection.122 The surveillance project expanded and evolved into National Healthcare Safety Network (NHSN), of which Dialysis Event Surveillance is a component (https://www.cdc.gov/nhsn/dialysis/index.html).The NHSN is an Internet-based surveillance system that enables facilities to report healthcare-associated infection data to the CDC. VAIs in dialysis patients and related events are reported to NHSN’s Dialysis Event Surveillance. Outpatient hemodialysis facilities in the United States eligible to participate in the surveillance are instructed to follow a standard protocol,125 by which all outpatients who receive hemodialysis at the facility are monitored for three NHSN-defined dialysis events. The three types of dialysis events (positive blood culture; intravenous antimicrobial start; and pus, redness, or increased swelling at the vascular access site) are reported using a standard data collection form. During 2007–2011, 193 facilities reported to NHSN; the rate of bloodstream infection (BSI) and access-related BSI was 1.27 and 0.88 per 100 patient-months, respectively.126 Data reported to NHSN have been used by CMS as part of the ESRD Quality Incentive Program since 2012; as a result, almost all outpatient hemodialysis facilities now report to NHSN. In 2014 more than 6000 facilities now reported 160,971 events, including 29,516 BSIs and 22,576 access-related BSIs; the rate of BSI was 0.64 per 100 patient-months. The rate of BSI was much higher among patients with a central venous catheter (2.16 per 100 patient-months) compared with other vascular access types.127

Vascular Access Infections

Access site infections are particularly important because they can cause disseminated bacteremia or loss of the vascular access. Local signs of VAI include erythema, warmth, induration, swelling, tenderness, breakdown of skin, loculated fluid, or purulent exudates.116, 117, 122, 128 Based on data from DSN collected during 1995–2005, the overall VAI rate was 3.1 per 100 patient-months and varied from 0.6 for fistulas to 10.1 for temporary catheters.129 In the 2014 NHSN surveillance data report, the VAI rate was 1.21 per 100 patient-months.127 The access-related BSI rate was 0.49 per 100 patient-months, which varied by access type: 0.16 for fistulas, 0.27 for grafts, and 1.83 for central venous catheters (tunneled and nontunneled).

VAIs are caused (in descending order of frequency) by Staphylococcus aureus (32% to 53% of cases), coagulase negative staphylococci (20% to 32% of cases), gram-negative bacilli (10% to 18%), other gram-positive cocci (including enterococci; 10% to 12%), and fungi (<1%).122, 129, 130 Among BSIs, S. aureus remained the most commonly reported pathogen in 2014 NHSN data (31% of BSI and 32% of access-related BSI), and 40% of cases of S. aureus were resistant to methicillin.127

The primary risk factor for vascular access–related infection is access type, with catheters having highest risk for infection; grafts intermediate; and native arteriovenous (AV) fistulas the lowest.115, 116, 120, 127, 129, 130 Other potential risk factors for VAI include (1) location of the access in the lower extremity; (2) recent vascular access surgery; (3) trauma, hematoma, dermatitis, or scratching over the access site; (4) poor patient hygiene; (5) poor needle insertion technique; (6) older age; (7) diabetes; (8) immunosuppression; (9) iron overload; (10) intravenous drug use; and (11) chronic inflammatory state.116, 117, 131, 132, 133, 134, 135, 136

Based on the relative risk for both infectious and noninfectious complications, native AV fistulas are considered the preferred vascular access type; a goal of no more than 10% of patients maintained with permanent catheter–based hemodialysis treatment is recommended.137, 138, 139, 140, 141 To minimize infectious complications, patients should be referred early for creation of an arteriovenous access, thereby decreasing the time dialyzed through a temporary catheter. During the period between 1995 and 2002, the percentage of patients dialyzed through fistulas increased from 22% to 33%, with most of the increase occurring after 1999.49 Data from Dialysis Outcomes and Practice Patterns Study indicated that from August 2010 to August 2013, AV fistula use increased from 63% to 68%, whereas catheter use declined from 19% to 15%.142 However, the majority of incident patients still initiated dialysis with a catheter. The US Renal Data System (USRDS) annual data report for 2016 indicated that whereas 18.8% of prevalent hemodialysis patients used a catheter, 80.3% of incident patients started dialysis with a catheter.1

Etiology and Prevention of Bloodstream Infection

Bacterial pathogens causing infection can either be exogenous (i.e., acquired from contaminated dialysis fluids or equipment) or endogenous (i.e., caused by invasion of bacteria present in or on the patient). Catheter-related infections are most often caused by bacteria from the patient’s skin colonizing the outside of the catheter or from direct contact (e.g., touch contamination by healthcare personnel) with the catheter hub, leading to contamination of the inner surface of the catheter. Surveillance data indicate that S. aureus and other coagulase-negative staphylococci were the most common pathogens for BSI and access-related BSI.127, 130 Endogenous sources may also be more likely causes of VAI among fistula and graft patients. Contaminated infusates and hematogenous spread are thought to be less common causes of BSI in this patient population, regardless of vascular access type.

Exogenous pathogens have caused numerous outbreaks, most of which resulted from inadequate dialyzer reprocessing procedures (e.g., contaminated water or inadequate disinfectant concentration) or inadequate disinfection and maintenance of the water treatment and distribution system. During 1995–2006, five outbreaks were traced to contamination of the waste handling option on one type of dialysis machine.41, 42, 43, 143, 144, 145 Recommendations to prevent such outbreaks have been published elsewhere.146

Contaminated medication vials are also a source of bacterial infection for patients. In 1999, an outbreak of Serratia liquefaciens bloodstream infections and pyrogenic reactions among hemodialysis patients was traced to contamination of vials of erythropoietin. These vials, which were intended for single use, were contaminated by repeated puncture to obtain additional doses and by pooling of residual medication into a common vial.147

Recommendations for preventing VAIs have been developed by the CDC148 and the Healthcare Infection Control Practices Advisory Committee149 and the National Kidney Foundation.137, 138, 139, 140, 141 The CDC has developed a recommended “Approach to BSI Prevention in Dialysis Facilities” that includes core interventions to prevent BSI among hemodialysis patients (Table 25.4 ). Facilities that implemented this set of interventions were able to reduce their access-related BSI rates and sustained these lowered rates for at least 4 years.150 The core interventions include (1) BSI surveillance using NHSN and feedback to clinical staff; (2) hand hygiene observations with feedback to staff; (3) catheter/vascular access care observations to ensure clinical staff adherence to aseptic technique and good infection control practices (with staff feedback); (4) development of staff infection prevention skills, demonstrated through competency assessments; (5) patient education and engagement in infection control processes; (6) decrease catheter prevalence; (7) catheter hub disinfection; and (8) bacitracin zinc/polymyxin B sulfate (Polysporin) triple ointment or povidone-iodine ointment applied to catheter exit sites. The CDC has also developed tools, protocol, and guidance to assist in the implementation of the interventions (https://www.cdc.gov/dialysis/prevention-tools/index.html).

TABLE 25.4.

Core Interventions for Dialysis Bloodstream Infection Prevention

Surveillance and feedback using NHSN Conduct monthly surveillance for BSIs and other dialysis events using NHSN, and actively share results with frontline clinical staff.
Hand hygiene observations Perform observations of hand hygiene opportunities monthly and share results with clinical staff.
Catheter/vascular access care observations Perform observations of vascular access care and catheter accessing quarterly. Assess staff adherence to aseptic technique when connecting and disconnecting catheters and during dressing changes. Share results with clinical staff.
Staff education and competency Train staff on infection control topics, including access care and aseptic technique. Perform competency evaluation for skills such as catheter care and accessing every 6–12 months and on hire.
Patient education/engagement Provide standardized education to all patients on infection prevention topics.
Catheter reduction Incorporate efforts (e.g., through patient education, vascular access coordinator) to reduce catheters by identifying and addressing barriers to permanent vascular access placement and catheter removal.
Chlorhexidine for skin antisepsis Use an alcohol-based chlorhexidine (>0.5%) solution as the first-line skin antiseptic agent for central line insertion and during dressing changes.
Catheter hub disinfection Scrub catheter hubs with an appropriate antiseptic after cap is removed and before accessing.
Antimicrobial ointment Apply triple antibiotic ointment or povidone-iodine ointment to catheter exit sites during dressing change.

Other strategies that might assist in implementation of recommended interventions include staff engagement and safety culture. Use of a behavioral change strategy (“Positive Deviance”), in which positive BSI prevention practices by certain staff were encouraged among all staff, was found to contribute to the reduction of BSI in one dialysis facility.151

Additional recommendations for preventing hemodialysis-catheter–associated infections include (1) using sterile technique and maximal sterile barrier precautions (cap, mask, sterile gown, large sterile drapes, and gloves) during catheter insertion; (2) limiting use of noncuffed catheters to 3 to 4 weeks; (3) restricting catheter manipulation and dressing changes to trained personnel; (4) replacing catheter site dressing if damp, loosened, or soiled.148, 152

A number of studies have looked at the use of various antimicrobial locks to prevent catheter-related BSI among hemodialysis patients. Two meta-analyses of these studies concluded that (1) antimicrobial catheter lock solutions reduce catheter-related bloodstream infections and the (2) use of these lock solutions should be considered in routine clinical practice in conjunction with other prevention modalities.153, 154 However, the long-term consequence of using antibiotics routinely in catheter locking solutions is unknown. CDC and the Healthcare Infection Control Practices Advisory Committee guidelines recommend lock solutions in patients with multiple BSIs despite optimal adherence to aseptic technique.149 Routine prophylactic use of antimicrobial lock solutions for hemodialysis catheter–related BSI is not recommended at this time.148, 155

In hemodialysis patients, the Infectious Diseases Society of America has recommended treatment with nasal mupirocin in documented S. aureus carriers who have catheter-related BSI with S. aureus and continue to need a hemodialysis catheter.156, 157 Otherwise the routine use of nasal mupirocin in patients with hemodialysis catheters is not recommended by either the CDC or the National Kidney Foundation.137, 138, 148 The CDC also updated the Guidelines for the Prevention of Intravascular Catheter-Related Infections and included the recommendation of using chlorhexidine-impregnated dressings to protect the insertion site of short-term, nontunneled central venous catheters in patients aged 18 years and older (https://www.cdc.gov/infectioncontrol/guidelines/bsi/c-i-dressings/recommendations.html). However, no recommendations were made for patients with long-term, tunneled catheters, and the effect of chlorhexidine-impregnated dressings on reducing catheter-related bloodstream infections among hemodialysis patients remains unclear.158, 159

A recently developed chlorhexidine-impregnated catheter cap (ClearGuard®) has been reported in a cluster randomized trial to reduce catheter-related BSIs and hospital admissions for BSI.160 A needle-free connector (TEGO® needle-free hemodialysis connector [ICU Medical, Inc., San Clemente, Calif.]) was found to be significantly associated with less intravenous antibiotic use among hemodialysis patients; however, the risk for catheter-related BSI among patients who used the connector was not statistically significantly decreased.161

Poor injection safety practices have led to BSI among dialysis patients, and thus improving injection practices should be considered as a strategy to reduce the spread of both bloodborne viruses (e.g., hepatitis B and C) and BSIs.147 To reduce the risk for infection, the CDC recommends (a) preparing medications in a clean room or, if a clean room is not available, in an area separated from the patient treatment area and designated for medications; (b) performing hand hygiene and using aseptic technique when preparing medication; (c) disinfecting the rubber septum of vials with alcohol and using a new needle and a new syringe to withdraw medication; (d) discarding single-dose vials and storing multidose vials appropriately; (e) not handling or storing used supplies, equipment, blood samples, or biohazard containers in or adjacent to areas where medications and clean (i.e., unused) equipment and supplies are handled; (f) delivering medications separately to each patient and not using common carts within the patient treatment area to prepare or distribute medications; and (g) performing hand hygiene, putting on new, clean gloves, scrubbing the injection port with antiseptic, and using aseptic technique when administering medications.162 Intravenous medication vials labeled for single use, including erythropoietin, should not be punctured more than once. Multidose medication vials should be assigned to a single patient whenever possible.163

Respiratory Infections

Hospital admissions for pneumonia have been declining overall for dialysis patients; however, pneumonia rates for hemodialysis patients are 1.8 to 2.0 times that of renal transplant recipients or peritoneal dialysis patients. Hospital admissions for pneumonia are also 102% higher among hemodialysis patients compared with the general population.164 In one study of a group of 433 dialysis patients over a 9-year period, pneumonia was the third most common cause of infection (after vascular access and infections below the knee) and accounted for 13% of all infections.165 One- and five-year survival probabilities are 0.55 and 0.17, respectively. Pneumonia is common among hemodialysis patients, carries a poor prognosis, and is often the antecedent to cardiovascular death.166, 167 A recent analysis of incident hemodialysis patients found pneumonia to be associated with chronic obstructive pulmonary disease, inability to transfer or ambulate, hemodialysis as initial therapy, advanced age (≥75 years), and body mass index ≥ 30 kg/m2.167 According to the Advisory Committee on Immunization Practices, patients with chronic renal failure should be vaccinated with the pneumococcal polysaccharide vaccine.168 Both 13-valent pneumococcal conjugate vaccine and 23-valent pneumococcal polysaccharide vaccine can be used; the schedule depends on the vaccination status of patients and is available on the CDC website (https://www.cdc.gov/dialysis/pdfs/vaccinating_dialysis_patients_and_patients_dec2012.pdf).

Patients with chronic kidney diseases, including hemodialysis patients, are at high risk for developing complications of seasonal influenza,169 which can be effectively prevented by vaccination. Influenza vaccination is associated with lower risk for hospitalization and death in ESRD patients.170 Although transmission of influenza, even during pandemics, in US dialysis clinics is not evident through the published literature, anecdotal reports of transmission exist. Because of their higher risk for complications, it is important to maintain influenza vaccination coverage among hemodialysis patients. In addition to influenza vaccination for patients, vaccination for dialysis providers (clinicians, nurses, technicians) is also important. Vaccination for healthcare personnel has been found to decrease absenteeism and healthcare-facility acquired influenza.171, 172, 173 However, coverage among dialysis healthcare personnel was still suboptimal: data indicated that only 73% of healthcare personnel in dialysis clinics received influenza vaccination in the 2011–2012 season.174 Annual vaccination is therefore recommended for both dialysis patients and healthcare personnel.169

ESRD patients with latent tuberculosis (TB) infection are at higher risk for developing TB disease. For this reason, the CDC recommends that all dialysis patients be tested at least once on admission for latent TB infection or TB disease using a tuberculin skin test or TB blood test.175 Patients who test positive should be evaluated for treatment and for the presence of TB disease. TB transmission in US dialysis facilities has been very rare. The most recently reported instance occurred in 2003 when an infected healthcare worker transmitted the bacteria to patients and other healthcare workers at a dialysis facility.176 Another episode in 1998 involved a patient with smear-positive pulmonary TB, but no transmission to other patients at the dialysis facility was identified.177 Suspected or confirmed TB exposure occurring within a dialysis facility should be reported to the appropriate state or local public health authority.

A new emerging respiratory infection, Middle East respiratory syndrome (MERS) caused by a corona virus, was first reported in 2012.178 No MERS infections or transmissions have been reported in the United States, but because of their significance and transmissibility, healthcare facilities, including dialysis clinics, should remain vigilant for MERS and other respiratory pathogens.

To prevent the transmission of respiratory infections (e.g., influenza) in dialysis facilities, staff should have systems in place to detect patients with respiratory symptoms on presentation to the facilities and implement interventions to decrease transmission. Facilities should educate patients about respiratory hygiene and provide necessary supplies such as tissues, mask, and hand hygiene materials. Patients should be encouraged to notify facility staff of any respiratory symptoms when they arrive. Facilities should also have policies that encourage dialysis healthcare personnel to not work while sick with respiratory infection.179 For new and emerging pathogens, dialysis providers should maintain awareness of current issues and recommendations from state and local public health departments and the CDC. Any possible instances of transmission of one of these new and emerging pathogens in a dialysis facility should be reported to public health authorities.

Antimicrobial-Resistant Bacteria

Hemodialysis patients have been in the forefront of the epidemic of antimicrobial resistance, especially vancomycin resistance. One of the earliest reports of vancomycin-resistant enterococci (VRE) was from a renal unit in London in 1988.180 The prevalence of VRE stool colonization among dialysis patients has varied from 1.5% among pediatric dialysis patients in the United Kingdom181 and 2.4% of adult dialysis patients at three dialysis centers in Indianapolis, Indiana,182 to 9.5% at a university hospital in Baltimore, Maryland.183 In one center the prevalence of rectal carriage of VRE was 9%, and 2% of noncarriers developed VRE infections in 1 year.184 A meta-analysis of studies from 100 facilities and 4800 patients worldwide reported a pooled VRE colonization prevalence of 6.2%.185 It appears that hospital acquisition of VRE contributes substantially to the increasing prevalence of VRE in the maintenance hemodialysis patient population.186 Among enterococci causing bloodstream infections in hemodialysis patients, up to 11.4% have been reported to be resistant to vancomycin.122, 127, 187, 188

Vancomycin resistance in S. aureus has also been reported in dialysis patients. Five of the first six US patients with infections associated with vancomycin-intermediate S. aureus were receiving either peritoneal dialysis or hemodialysis.189, 190 In addition, the first US patient found to be infected with a vancomycin-resistant S. aureus (VRSA) strain was a maintenance hemodialysis patient; the VRSA was isolated from a diabetic foot wound and from a temporary central venous catheter exit site.191 In the period between 2002 and 2009 there were nine cases of VRSA in the United States; three of these patients had chronic renal failure and two were hemodialysis patients.192, 193 Five of those VRSA cases occurred in southeastern Michigan and contained a plasmid carrying the vanA gene, which had been donated from a VRE donor.194 To date, 14 cases of VRSA have been reported to the CDC, of which the most recent case was in a dialysis patient.195 A guide to investigation and control of VRSA is available from the CDC196 and includes suggested strategies for VRSA control in dialysis centers.

The percentage of hemodialysis facilities reporting methicillin-resistant S. aureus (MRSA) infection or colonization has increased from 40% in 199596 to 76% in 2002.49 In a 2005 CDC study assessing the incidence of invasive MRSA infection among dialysis patients, the incidence of invasive MRSA infection was found to be 42.5 cases per 1000 dialysis patient population.197 This is approximately 100-fold higher than the general population, in which rates for invasive MRSA infection are 0.2 to 0.4 cases per 1000 population. The rate of invasive MRSA infections among hemodialysis patients appears to be decreasing.198 In 2015, invasive MRSA incidence had decreased to 14.8 cases per 1000 population, still much higher than the incidence among general population.199 A study in the United Kingdom of VAIs found that MRSA was responsible for 30% of S. aureus catheter-related infections in hemodialysis patients.200 In the United States, 30.6% of BSIs in hemodialysis patients were caused by S. aureus and 39.5% of the S. aureus BSI isolates were methicillin-resistant strains.127

Patients with chronic kidney disease, including end-stage renal disease, are at high risk for Clostridium difficile infection (CDI).201 Limited data are available on CDI among dialysis patients in the United States. In a review of USRDS (Medicare claims) data between 2005 and 2008, 4.25% of dialysis patients were diagnosed with first episode of CDI.202 In a cohort of dialysis patients followed from 1999 to 2007, 14.3% of hemodialysis patients developed CDI (a rate of 8.3 cases per 100 patient-years).203 The UK Renal Registry reported an incidence of 1.09 CDI per 100 patient-years among hemodialysis patients in 2013–2014.204 An outbreak of CDI in a hemodialysis facility has been reported. The outbreak investigation revealed several challenges in prevention and control of CDI among dialysis patients (e.g., shared patient environment and equipment, lack of physical barriers between patient treatment stations, and adequacy of typical cleaning and disinfection procedures).205 CDI control strategies that were employed during this outbreak included designation of select dialysis stations as CDI contact isolation stations, use of dedicated, disposable gown and gloves by staff while caring for a patient in contact isolation, handwashing with soap and water after caring for CDI patients, use of 1:10 dilution of bleach to disinfect environmental surfaces in stations after treatment of CDI patients, and heightened diligence to ensure adequate wet contact time of bleach on surfaces.

To combat emerging antimicrobial resistance in dialysis patients, one must understand the transmission kinetics involved with each organism. For certain patients, including those infected with MRSA or VRE, contact precautions are used in the hospital setting.162 The CDC has not recommended routine use of contact precautions in hemodialysis centers for patients infected or colonized with multidrug-resistant organisms (MDROs). Transmission of pathogenic bacteria is well documented in hospitals. At least one study has suggested that the majority of transmission and acquisition of resistant pathogens among dialysis patients occurs when these patients are admitted to the acute care setting.186 However, studies have demonstrated MDRO spread in dialysis centers.205, 206 The CDC recommends additional precautions be used during treatment of patients who might be at higher risk for transmitting pathogenic bacteria (i.e., those with an infected skin wound with drainage that is not contained by dressings or fecal incontinence or uncontrolled diarrhea). These interventions include the following: (1) Staff members treating the patient should wear a separate gown over their usual clothing and remove the gown when finished caring for the patient; (2) patients should be dialyzed at a station away from the main flow of traffic and with as few adjacent stations as possible (e.g., at the end or corner of the unit).162 However, preventing transmission of resistant pathogens depends primarily on adherence to basic infection control practices and these additional practices. More work is needed to understand the transmission of targeted MDROs in dialysis settings and the effectiveness of interventions to reduce transmission.

One major contributor to the development of antimicrobial-resistant bacteria is inappropriate use of antimicrobial drugs. Antibiotics are commonly used in dialysis patients, especially vancomycin, cefazolin, and third- and fourth-generation cephalosporins. In a small study, as many as 30% of antibiotic indications were found to be inappropriate.207 Reasons for those inappropriate uses and possible strategies for improved antibiotic stewardship in dialysis facilities have been proposed.208 More data are needed to understand the relationship between antibiotic prescribing patterns in dialysis centers and antibiotic resistance to better target potential stewardship activities.209

Hepatitis C Virus

HCV is a single-stranded RNA virus that belongs to the family Flaviviridae.210 HCV was first recognized as non-A, non-B hepatitis virus in 1974 until cloning of the etiological agent in 1989.211, 212, 213 HCV is a relatively efficiently transmitted bloodborne viral pathogen in the dialysis setting. It is not as efficiently transmitted as HBV in this setting, and generally, recommended infection control practices do prevent transmission among hemodialysis patients (without need for isolation).162, 214, 215, 216 However, new acquisition of hepatitis C infection continues to occur among maintenance hemodialysis patients and outbreaks of hepatitis C are far more common than outbreaks of hepatitis B in the dialysis setting.

Epidemiology

In 2002, 63% of dialysis centers tested patients for antibodies against HCV (anti-HCV). In the facilities that performed screening, the incidence rate in 2002 was 0.34%, and among these centers, the prevalence of anti-HCV among patients was 7.8%, a decrease of 25.7% since 1995.49 Only 11.5% of dialysis facilities reported newly acquired HCV infection among their patients. Higher incidence rates have been reported from cohort studies of dialysis patients in the United States (<1% to 3%), Japan (<2%), and Europe (3% to 15%).217, 218, 219, 220, 221, 222, 223, 224 Higher prevalence rates (10% to >85%) also have been reported in individual facilities and in other countries.220, 224, 225, 226, 227, 228, 229

HCV is moderately stable in the environment and can survive drying and environmental exposure to room temperature for at least 16 hours.230 Longer survival, up to several weeks, has been reported.231 HCV is most efficiently transmitted by direct percutaneous exposure to blood, and like HBV, the chronically infected patient is central to the epidemiology of HCV transmission. Risk factors associated with HCV infection among hemodialysis patients include blood transfusions from unscreened donors, injection drug use, low staff-to-patient ratios, dialysis in a facility with high HCV prevalence, and number of years on dialysis.217, 223, 232, 233, 234, 235, 236 The number of years on dialysis is a risk factor that is independently associated with higher rates of HCV infection. Multiple studies found that as the time patients spent on dialysis increased, their prevalence of HCV infection increased.217, 236, 237, 238

These studies, as well as investigations of dialysis-associated outbreaks of hepatitis C infection, indicate that HCV transmission most likely occurs because of inadequate infection control practices.239 The practices that have been found to be associated with higher prevalence of HCV in dialysis facilities include handling blood specimens near medication preparation area or other clean areas, use of a mobile cart to distribute medications, poor disinfection of priming buckets, and inconsistent cleaning of dialysis machines.240 The CDC tracks HCV outbreaks in dialysis settings (https://www.cdc.gov/hepatitis/outbreaks/healthcarehepoutbreaktable.htm); during 1998–2008, the CDC helped investigate five outbreaks of HCV infection among patients in hemodialysis centers.241, 242 From 2008 to 2015, 18 outbreaks involving at least 98 newly infected patients were reported to the CDC.243 In those outbreaks a common finding was that seroconversions were associated with receiving dialysis immediately after or at a machine adjacent to a chronically infected patient.46, 244 Multiple opportunities for cross-contamination were observed in the involved facilities, including (a) equipment and supplies that were not disinfected between patient use; (b) use of common medication carts to prepare and distribute medications at patient stations; (c) sharing of multiple dose vials, which were used at patients’ stations (e.g., observed to be placed on the top of the hemodialysis machine); (d) contaminated priming buckets that were not routinely changed or cleaned and disinfected between patients; (e) machine surfaces that were not routinely cleaned and disinfected between patients; and (f) blood spills that were not cleaned up promptly. Investigation of an outbreak involving four different clusters found multiple lapses in infection control and blood contamination of environmental surfaces as a result of poor cleaning and disinfection practice.46 In these outbreaks, a single common exposure event is rarely identified, and many outbreaks involve separate chains of transmission occurring over time. Moreover, it has been noted that station turnover procedures are rushed and disinfection of machine surfaces is initiated before the patient has left the treatment station. These common practices are challenges to proper cleaning and disinfection and prevention of cross-transmission of bloodborne pathogens such as HCV.

Other traditional risk factors for acquiring HCV include injection drug use, exposure to an HCV-infected sexual partner or household contact, multiple sexual partners, and perinatal exposure.245, 246 The efficiency of transmission in settings involving sexual or household exposure to infected contacts is low, and the magnitude of risk and the circumstances under which these exposures result in transmission are not well defined. When a new HCV infection (includes acute, symptomatic infection or HCV seroconversion) occurs in a dialysis facility, it should be assumed that the infection was healthcare related and investigated as such. State and local health departments to whom these infections should be reported have extensive expertise in evaluating traditional risk factors that the patient might have in addition to healthcare exposures.

Treatment for HCV infection has gained significant achievements in the past several years, and recent data have indicated that ESRD patients infected with HCV can be treated successfully.247, 248 All dialysis patients with HCV infection should be referred to care and assessment. Because dialysis in a facility with high HCV prevalence is a risk factor for HCV infection, HCV treatment may reduce the number of infected patients and therefore help decrease the number of new infections. However, the effect of HCV treatment on transmission of HCV in dialysis facilities is unknown.

Screening and Diagnostic Tests

FDA-licensed or approved tests to screen for HCV antibodies (anti-HCV) in the United States comprise immunoassays, immunoblot assays, and immunochromatography-based rapid tests. None discriminate between active and resolved HCV infection, and confirmatory recombinant immunoblot tests have been discontinued.249 All individuals who test anti-HCV positive should be further tested for HCV RNA by an FDA-approved nucleic acid test to determine current infection status.250

Routine testing of hemodialysis patients for anti-HCV on admission and every 6 months has been recommended since 2001.162 For routine HCV screening of hemodialysis patients, the anti-HCV screening immunoassay (either rapid test or laboratory-based assay) is recommended, and if positive, this should be confirmed with HCV RNA testing (Box 25.1 ).250

BOX 25.1. Interpretation of Test Results for Hepatitis C Virus Infection.

Anti-HCV Positive

An anti-HCV positive result is consistent with current HCV infection, past HCV infection that has resolved, or biological false positivity for HCV antibody. Test for HCV RNA to identify current infection.

HCV RNA Positive
  • An HCV RNA–positive result indicates current (active) infection.

  • All HCV RNA–positive persons should receive counseling, undergo medical evaluation, and be considered for treatment.

Anti-HCV Negative
  • Anti-HCV negative result is defined as an anti-HCV screening test negative.

  • An anti-HCV–negative individual is considered uninfected. However, patients with exposure within the previous 6 months should be tested for HCV RNA or have a follow-up anti-HCV test ≥6 months after last exposure.

Anti-HCV, Antibody to hepatitis C virus.

Prevention of Hepatitis C Virus Transmission

Lessons from investigations of HCV outbreaks in dialysis indicate that breaches in infection control practices are the major contributors to HCV transmission. The following recommendations can be applied to prevent transmission of HCV in dialysis facilities (https://emergency.cdc.gov/han/han00386.asp): (1) Evaluate infection control practices in each facility and ensure adherence to infection control standards. CDC audit tools can be used to help assess practices such as injection medication preparation and administration, hand hygiene, and routine environmental surface cleaning and disinfection; (2) promptly address any gaps in infection control identified; (3) ensure dialysis staff are aware of and trained to implement infection control guidelines162; (4) follow CDC recommendations for HCV screening of hemodialysis patients and management of patients who test positive; (5) immediately report any case of new HCV infection among patients undergoing hemodialysis to the state or local health department. Any new HCV infections among hemodialysis patients should be investigated.251

HCV-positive patients do not have to be isolated from other patients or dialyzed separately on dedicated machines and can participate in dialyzer reuse programs.252 They should be referred for evaluation and treatment according to current medical practice guidelines.

Hepatitis B Virus

HBV is the most highly efficiently transmitted pathogen in the dialysis setting. Recommendations for control of hepatitis B in hemodialysis setting were first published in 1977,253 and by 1980 their widespread implementation was associated with a sharp decrease in the incidence of HBV infection among both patients and staff members.254, 255 In 1982 the hepatitis B vaccine was recommended for all susceptible patients and staff members.256 Hepatitis B vaccination is currently the standard of care and is recommended to all susceptible hemodialysis patients. The vaccine series should ideally be administered before starting dialysis for ESRD.162

Epidemiology

During the early 1970s, HBV infection was endemic in maintenance hemodialysis units and outbreaks were common. Subsequently, the incidence and prevalence of HBV infection among maintenance hemodialysis patients in the United States has declined dramatically and by 2002 was 0.12% and 1%, respectively.49 Data from 2002 indicated that newly acquired HBV infections were reported by 2.8% of US hemodialysis centers, and 27.3% of centers reported one or more chronically infected patients.49 New hepatitis B infections in hemodialysis patients are now rarely reported.

The chronically infected patient is central to the epidemiology of HBV transmission. HBV is transmitted by percutaneous (i.e., puncture through the skin) or mucosal (direct contact with mucous membranes) exposure to infectious blood or body fluids that contain blood. All hepatitis B surface antigen (HBsAg)–positive persons who are also positive for hepatitis Be antigen (HBeAg) have an extraordinary level of HBV circulating in their blood, approximately 108 to 109 virions per milliliter.257, 258 With virus titers this high in blood, body fluids containing serum or blood may also contain high levels of HBV and are potentially infectious. Furthermore, HBV at titers of 102 to 103 virions/mL can be present on environmental surfaces in the absence of any visible blood and still cause infection.257, 259, 260, 261

HBV is relatively stable in the environment and has been found to remain viable for at least 7 days on environmental surfaces at room temperature.257, 259, 261 HBsAg has been detected in dialysis facilities on hemostats, scissors, dialysis machine control panels, and door knobs.261 Thus blood-contaminated surfaces that are not routinely cleaned and disinfected represent a reservoir for HBV transmission. Dialysis staff members can transfer virus to susceptible patients through contamination in the environment.257, 259, 261

Most HBV outbreaks among hemodialysis patients (see Table 25.3) were caused by cross-contamination to patients via (1) environmental surfaces, supplies (e.g., hemostats, clamps, etc.), or equipment that were not routinely clean and disinfected after each use; (2) multiple-dose vials or intravenous solutions that were not used exclusively for one patient; (3) medications for injections that were prepared adjacent to areas where blood samples were handled; and (4) staff members who simultaneously provided care for both infected (HBsAg-positive) patients and susceptible patients.106, 262, 263, 264, 265, 266, 267, 268 Once the factors that promote HBV transmission among hemodialysis patients were identified, recommendations for control were published.253

The segregation of HBsAg-positive patients and their equipment from HBV-susceptible patients resulted in 70% to 80% reduction in the incidence of HBV infections among hemodialysis patients.255, 269, 270 The success of isolation practices in preventing transmission of HBV infection is linked to other infection control practices, including routine serological surveillance and routine cleaning and disinfection. Frequent serological testing for HBsAg detects patients recently infected with HBV so that isolation procedures can be implemented before cross-contamination can occur. Environmental control by routine cleaning and disinfection procedures reduces the opportunity for cross contamination, either directly from environmental surfaces or indirectly by hands of personnel.

In past studies, independent risk factors among maintenance hemodialysis patients for acquiring HBV infection included the presence of ≥1 HBV-infected patient in the hemodialysis facility who was not isolated, as well as a vaccination rate <50% among patients.89 However, transmission has been rarely reported in the United States in the past 20 years because of high rates of vaccination, screening, and isolation. The most recent documented transmission in a dialysis clinic in the United States was due to reactivation of hepatitis B infection that occurred in a patient with previous infection who became antigen positive as a result of immunosuppression.271 The CDC has received anecdotal reports of atypical hepatitis B serological test results among dialysis patients that may represent reactivation of HBV infection or HBV mutant strains; however, no further cases of dialysis-related transmission have been identified.

Other risk factors for acquiring HBV infection include injection drug use, sexual and household exposure to HBV-infected contacts, exposure to multiple sexual partners, male homosexual activity, and perinatal exposure. Dialysis patients should be educated about these and other risks and, for those patients with active HBV infection (HBsAg positive), informed that their sexual partners and household contacts should be vaccinated.272, 273, 274 HBV-infected patients should be evaluated for HBV treatment.

Screening and Diagnostic Tests

Several well-defined antigen-antibody systems are associated with HBV infection, including HBsAg and antibody to HBsAg (anti-HBs); hepatitis B core antigen (HBcAg) and antibody to HBcAg (anti-HBc); and HBeAg and antibody to HBeAg (anti-HBe). Serological assays are commercially available for all of these except for HBcAg because no free HBcAg circulates in the blood. One or more of these serological markers are present during different phases of HBV infection (Table 25.5 ).275 HBV infection can also be detected using qualitative or quantitative tests for HBV DNA.276, 277 These tests are most commonly used for HBV-infected patients being managed with antiviral therapy.278, 279, 280, 281, 282

TABLE 25.5.

Interpretation of Serological Test Results for Hepatitis B Virus Infection

Serologic Markers

HBsAg Total Anti-HBc IgM Anti-HBc Anti-HBs Interpretation
Susceptible, never infected
+ Acute infection, early incubation
+ + + Acute infection
+ + Acute resolving infection
+ + Past infection, recovered and immune
+ + Chronic infection
+ False positive (i.e., susceptible), past infection, or low-level chronic infection
+ Immune if titer ≥ 10 mIU/mL

Anti-HBc, Antibody to hepatitis B core antigen; Anti-HBs, antibody to hepatitis B surface antigen; HBsAg, hepatitis B surface antigen; IgM, Immunoglobulin M.

In some individuals the only HBV serological marker detected is total anti-HBc (i.e., isolated anti-HBc). Among most asymptomatic persons in the United States tested for HBV infection, an average of 2% (range: <0.1% to 6%) test positive for anti-HBc283; among injecting drug users, however, the rate is 24% to 28%.284, 285 This pattern can occur after HBV infection among individuals who have recovered but whose anti-HBs have waned or among individuals who have low-level chronic HBV infection and failed to develop anti-HBs. It may also represent a false positive total anti-HBc result or someone in the window of infection. HBV DNA has been detected in <10% of individuals with isolated anti-HBc, and these individuals are unlikely to be infectious to others except under unusual circumstances involving direct percutaneous exposures to large quantities of blood (e.g., transfusion).286, 287, 288 In most persons with isolated anti-HBc, the result appears to be false positive. Data from several studies have indicated that a primary anti-HBs response develops in most of these individuals after a three-dose series of hepatitis B vaccinations.289, 290 No data exist on response to vaccination among hemodialysis patients with this serological pattern. Testing and follow-up recommendations for hemodialysis patients with isolated anti-HBc are available.162

Prevention of Hepatitis B Virus Transmission

The following recommendations can be applied to prevent transmission of HBV in hemodialysis facilities: (1) serological screening of patients (and staff members) for HBV infection, including monthly testing of all susceptible patients for HBsAg; (2) HBV vaccination of susceptible patients (and patient care staff); (3) isolation of all HBsAg-positive patients in a separate room; (4) assignment of staff members to HBsAg-positive patients and not to HBV-susceptible patients during the same or overlapping shifts; (5) assignment of dedicated dialysis equipment to HBsAg-positive patients; (6) cleaning and disinfection of nondisposable items (e.g., hemostats, clamps, scissors) before use on another patient; (7) glove use whenever patient or hemodialysis equipment is touched and glove changes and hand hygiene between each patient (and station); and (8) routine cleaning and disinfection of equipment and environmental surfaces.162, 253 Because dialysis patients can have waning immunity to hepatitis B vaccine, patients who require one or more booster doses of vaccine should not be cared for by the same staff as infected patients.

Hepatitis Delta Virus

Delta hepatitis is caused by the hepatitis delta (HDV), a relatively small defective virus that causes infection only in persons with active HBV infection. The prevalence of HDV infection is extremely low in the United States, with rates <1% among HBsAg-positive persons in the general population and >10% among HBsAg-positive persons with repeated percutaneous exposures (e.g., intravenous drug users, persons with hemophilia).291

Only one transmission of HDV among dialysis patients has been reported in the United States.292 In this episode, transmission occurred from a patient who was chronically infected with HBV and HDV to an HBsAg-positive patient after a massive bleeding incident; both patients received dialysis at the same station. Therefore, in dialysis settings, HDV-infected patients should be isolated from other HBV-infected patients.

Human Immunodeficiency Virus Infection

During 1985–2002, the percentage of US hemodialysis centers that reported providing maintenance hemodialysis for patients with HIV infection increased from 11% to 39% and the proportion of patients with known HIV infection increased from 0.3% to 1.5%.49 Although the proportion of patients with HIV infection has remained stable during the past decade, the number of infected patients has increased, as has the number of centers treating patients with HIV infection. HIV is transmitted by blood and other body fluids that contain blood. No patient-to-patient transmission of HIV has been reported in a US hemodialysis center. However, there have been reports of transmission of HIV among patients in other countries. All these outbreaks have been attributed to several breaks in infection control: (a) reuse of access needles and inadequately disinfected equipment, (b) sharing of syringes among patients, and (c) and sharing of dialyzers among different patients.293, 294, 295, 296, 297 The most recent reported outbreak involved three new HIV infections and was associated with sharing of multidose heparin vials, inadequately disinfected hemodialysis equipment, and dialysis staff who used blood-contaminated gloves to manipulate vascular access for multiple patients.298 Adherence to recommended infection control practices is adequate to prevent HIV transmission in dialysis facilities.162

Other Emerging Infections

In 2014 the largest outbreak of Ebola in history occurred in West Africa. Healthcare personnel caring for Ebola patients are at high risk for becoming infected, and during this outbreak, a significant number of healthcare personnel acquired the virus.299 Other high-consequence pathogens have continued to be identified, including Candida auris, a yeast that is resistant to multiple antifungals.300 Dialysis center staff and management should prepare for the possible introduction of highly virulent pathogens into their communities and dialysis centers by developing contingency plans, improving baseline adherence to recommended infection prevention practices, and strengthening communication channels with public health departments. The CDC has released on its website recommendations for infection control to prevent transmission of C. auris (https://www.cdc.gov/fungal/diseases/candidiasis/c-auris-infection-control.html), including dialysis-specific recommendations.

Summary of Recommendations and Future Directions

Preventing transmission of pathogens and reducing healthcare-associated infections among maintenance hemodialysis patients requires implementation of a comprehensive infection control program that can support consistent adherence to infection control recommendations (Table 25.6 ; BOX 25.2, BOX 25.3, BOX 25.4 ) among all staff members. Adherence to core prevention practices (see Table 25.4) has been found to sustainably reduce highly morbid bloodstream infections among dialysis patients with central venous catheters. An active infection control program is the foundation of these efforts. The components of such a program include routine implementation of infection prevention and control practices specifically designed for the hemodialysis setting: (1) each dialysis facility should have at least one staff member with basic infection control knowledge and experience in addition to being able to access personnel with advanced infection control expertise; (2) infection prevention training and education should be provided to both staff and patients; (3) regular auditing of infection prevention practices should be conducted (audit and assessment tools are available at https://www.cdc.gov/dialysis/prevention-tools/index.html); (4) a culture of safety should be developed, including engaged leadership and involvement of frontline staff in infection prevention efforts; (5) routine serological testing and immunization of patients and staff should be performed; (6) infection surveillance should be conducted and the data used for continuous quality improvement; and (7) systems should be in place for public health reporting. An excellent review of those essential components of an infection prevention program is available elsewhere.301 The CDC has also published recommendations describing these components in detail.162

TABLE 25.6.

Schedule for Routine Testing for Hepatitis B Virus and Hepatitis C Virus Infections

Patient Status On Admission Monthly Semi-Annual Annual
All patients HBsAg, Anti-HBc (total), Anti-HBs, Anti-HCV, ALT
HBV susceptible, including
vaccine nonresponders
HBsAg
Anti-HBs positive (≥10 mIU/mL), anti-HBc negative Anti-HBs
Anti-HBs and Anti-HBc positive No additional testing is needed
Anti-HCV negative ALT Anti-HCV

ALT, Alanine aminotransferase.

Results of HBV testing should be known before patient begins dialysis.

BOX 25.2. Recommended Infection Control Practices for Hemodialysis Units.

Infection Control Precautions for All Patients

  • Hand hygiene should be performed:
    • Before and after having direct contact with a patient’s intact skin
    • After contact with blood, body fluids or excretions, mucous membranes, non-intact skin, or wound dressings
    • After contact with inanimate objects (including medical equipment) in the immediate vicinity of the patient
    • If hands will be moving from a contaminated-body site to a clean-body site during patient care
    • After glove removal
  • Wear disposable gloves when caring for the patient or touching the patient’s equipment at the dialysis station; remove gloves and perform hand hygiene (if hands are visibly soiled wash with soap and water) between each patient or station.

  • Items taken into the dialysis station should be disposed of or cleaned and disinfected before taken to a common clean area or used on another patient.
    • Nondisposable items taken to the patient treatment station that cannot be cleaned or disinfected (e.g., adhesive tape) should be discarded after use.
    • Unused medications (including multi-dose vials) or supplies (syringes, alcohol swabs, etc.) taken to the patient’s station should be used only for that patient and should not be returned to a common clean area or used on other patients.
  • When multidose medication vials are used (including vials containing diluents), prepare individual patient doses in a clean (centralized) area away from dialysis stations and deliver separately to each patient. Do not carry multidose medication vials from station to station.

  • Do not use common medication carts to deliver medications to patients. Do not carry medication vials, syringes, alcohol swabs, or supplies in pockets. If trays are used to deliver medication to individual patients, they must be cleaned between patients.

  • Clean areas should be clearly designated for the preparation, handling, and storage of medications and unused supplies and equipment. Clean areas should be clearly separated from contaminated areas where used supplies and equipment are handled. Do not handle and store medications or clean supplies in the same or adjacent area to where used equipment or blood samples are handled.

  • Use external transducer protectors (venous or arterial) for each patient treatment to prevent blood contamination of the dialysis machine’s pressure monitoring equipment. Change these external transducer protectors between each patient treatment and when they become wet, and do not reuse them. The redundant internal transducer protectors do not need to be changed routinely between patients. If the external transducer protectors are contaminated with blood the internal transducer protector should be assessed for contamination before dialyzing another patient with the same machine.

  • Clean and disinfect the dialysis station (chairs, beds, tables, machines, etc.) between patients.
    • Start cleaning only when patient has left the station and only admit new patient after cleaning and disinfection are complete
    • Give special attention to cleaning control panels on the dialysis machine and other surfaces that are frequently touched and potentially contaminated with patient’s blood.
    • Discard all fluid, and clean and disinfect all surfaces and containers associated with the prime waste (including buckets attached to the machines).
  • For dialyzers and blood tubing that will be reprocessed, cap dialyzer ports and clamp tubing. Place all used dialyzers and tubing in a leak-proof containers for transport from station to reprocessing or disposal area.

Modified from Centers for Disease Control and Prevention, Recommendations for preventing transmission of infections among chronic hemodialysis patients. MMWR Recomm Rep, 2001. 50(RR-5): pp. 1-43.

BOX 25.3. Hepatitis B Vaccination.

  • Vaccinate all susceptible patients against hepatitis B

  • Test for anti-HBs 1–2 months after the last dose
    • If anti-HBs is <10 mIU/mL, consider patient susceptible, revaccinate with an additional three doses, and retest for anti-HBs
    • If anti-HBs is >10 mIU/mL, consider immune and retest annually
  • Give booster dose of vaccine if anti-HBs declines to <10 mIU/mL and continue to retest annually

BOX 25.4. Management of HBsAg-Positive Patients.

  • Follow infection control practices for hemodialysis units for all patients.

  • Dialyze HBsAg-positive patients in a separate room using separate machines, equipment, instruments, and supplies.

  • Staff members caring for HBsAg-positive patients should not care for HBV-susceptible patients at the same time (e.g., during same shift or during patient change over).

FDA Safety Alert. Modified from Centers for Disease Control and Prevention, Recommendations for preventing transmission of infections among chronic hemodialysis patients. MMWR Recomm Rep, 2001. 50(RR-5): pp. 1-43.

Future Directions

Infection control strategies that prevent HBV infection among hemodialysis patients have been well established; however, some questions remain. More work is needed to determine the ideal hepatitis B vaccine dosage regimen for pre- and postdialysis pediatric patients and for predialysis adult patients, as well as the optimal timing for follow-up testing and administration of booster doses among vaccine responders. Also, reports of patients with mutant HBV, patients with reverse seroconversion, and patients with atypical HBV serological test results highlight the need for more research to evaluate their significance in dialysis population. Further work is needed to clarify the specific factors responsible for transmission of HCV among hemodialysis patients and to evaluate the effect of current prevention recommendations, HCV treatment, and other strategies on prevention and control of HCV infection in this setting.

VAIs continue to be a devastating complication among patient receiving maintenance hemodialysis; additional interventions are needed to further reduce rates of these infections. Finally, other important questions about the role dialysis centers play in the spread of MDROs and the effectiveness of interventions designed to prevent MDRO transmission require further investigation.

Acknowledgments

We would like to thank Dr. Saleem Kamili and Ms. Anne Moorman from Division of Viral Hepatitis, Centers for Disease Control and Prevention, for their thoughtful comments. We would like to thank Ms. Stephanie Booth for her contribution to the chapter.

A full list of references is available at www.expertconsult.com.

References

  • 1.United States Renal Data System . National Institutes of Health, National Institute of Diabetes and Digestive and Kidney Diseases; Bethesda, MD: 2016. USRDS 2016 Annual Data Report: Atlas of Chronic Kidney Disease and End-Stage Renal Disease in the United States. [Google Scholar]
  • 2.Khan I.H., Catto G.R. Long-term complications of dialysis: infection. Kidney Int Suppl. 1993;41:S143–S148. [PubMed] [Google Scholar]
  • 3.Vanholder R., Ringoir S. Polymorphonuclear cell function and infection in dialysis. Kidney Int Suppl. 1992;38:S91–S95. [PubMed] [Google Scholar]
  • 4.Hindman S.H. Pyrogenic reactions during haemodialysis caused by extramural endotoxin. Lancet. 1975;2(7938):732–734. doi: 10.1016/s0140-6736(75)90721-7. [DOI] [PubMed] [Google Scholar]
  • 5.Gordon S.M. Pyrogenic reactions in patients receiving conventional, high-efficiency, or high-flux hemodialysis treatments with bicarbonate dialysate containing high concentrations of bacteria and endotoxin. J Am Soc Nephrol. 1992;2(9):1436–1444. doi: 10.1681/ASN.V291436. [DOI] [PubMed] [Google Scholar]
  • 6.Favero M.S. Gram-negative water bacteria in hemodialysis systems. Health Lab Sci. 1975;12(4):321–334. [PubMed] [Google Scholar]
  • 7.Archibald L.K. Pyrogenic reactions in hemodialysis patients, Hanoi, Vietnam. Infect Control Hosp Epidemiol. 2006;27(4):424–426. doi: 10.1086/503347. [DOI] [PubMed] [Google Scholar]
  • 8.Rudnick J.R. An outbreak of pyrogenic reactions in chronic hemodialysis patients associated with hemodialyzer reuse. Artif Organs. 1995;19(4):289–294. doi: 10.1111/j.1525-1594.1995.tb02331.x. [DOI] [PubMed] [Google Scholar]
  • 9.Jackson B.M. Outbreak of pyrogenic reactions and gram-negative bacteremia in a hemodialysis center. Am J Nephrol. 1994;14(2):85–89. doi: 10.1159/000168694. [DOI] [PubMed] [Google Scholar]
  • 10.Beck-Sague C.M. Outbreak of gram-negative bacteremia and pyrogenic reactions in a hemodialysis center. Am J Nephrol. 1990;10(5):397–403. doi: 10.1159/000168155. [DOI] [PubMed] [Google Scholar]
  • 11.Gordon S.M. Pyrogenic reactions associated with the reuse of disposable hollow-fiber hemodialyzers. JAMA. 1988;260(14):2077–2081. [PubMed] [Google Scholar]
  • 12.Roth V.R., Jarvis W.R. Outbreaks of infection and/or pyrogenic reactions in dialysis patients. Semin Dial. 2000;13(2):92–96. doi: 10.1046/j.1525-139x.2000.00027.x. [DOI] [PubMed] [Google Scholar]
  • 13.Pollak V.E. Adverse effects and pyrogenic reactions during hemodialysis. Jama. 1988;260(14):2106–2107. [PubMed] [Google Scholar]
  • 14.Lefton C.K. Patients suffer pyrogenic reactions in Philadelphia dialysis units. Nephrol News Issues. 1994;8(12):10. [PubMed] [Google Scholar]
  • 15.Nystrand R. The microbial world and fluids in dialysis. Biomed Instrum Technol. 2008;42(2):150–159. doi: 10.2345/0899-8205(2008)42[150:TMWAFI]2.0.CO;2. [DOI] [PubMed] [Google Scholar]
  • 16.Petersen N.J., Carson L.A., Favero M.S.. Bacterial endotoxin in new and reused hemodialyzers: a potential cause of endotoxemia. Trans Am Soc Artif Intern Organs. 27:155–160. [PubMed]
  • 17.Raij L., Shapiro F.L., Michael A.F. Endotoxemia in febrile reactions during hemodialysis. Kidney Int. 1973;4(1):57–60. doi: 10.1038/ki.1973.79. [DOI] [PubMed] [Google Scholar]
  • 18.Favero M.S. Factors that influence microbial contamination of fluids associated with hemodialysis machines. Appl Microbiol. 1974;28(5):822–830. doi: 10.1128/am.28.5.822-830.1974. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 19.Favero M.S., et al. Pseudomonas aeruginosa: growth in distilled water from hospitals. Science. 173(999):836–838. [DOI] [PubMed]
  • 20.Favero, M.S. and Bland, L.A. eds. Microbiologic principles applied to reprocessing hemodialyzers. Guide to reprocessing of hemodialyzers. ed. Deane N, Wineman R, and Bemis J. 1986, Martinus Nijhoff: Boston. 63–73.
  • 21.Carson L.A. Prevalence of nontuberculous mycobacteria in water supplies of hemodialysis centers. Appl Environ Microbiol. 1988;54(12):3122–3125. doi: 10.1128/aem.54.12.3122-3125.1988. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 22.Bolan G. Infections with Mycobacterium chelonei in patients receiving dialysis and using processed hemodialyzers. J Infect Dis. 1985;152(5):1013–1019. doi: 10.1093/infdis/152.5.1013. [DOI] [PubMed] [Google Scholar]
  • 23.Gomila M., Ramirez A., Lalucat J. Diversity of environmental Mycobacterium isolates from hemodialysis water as shown by a multigene sequencing approach. Appl Environ Microbiol. 2007;73(12):3787–3797. doi: 10.1128/AEM.02934-06. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 24.Basok A. Spectrum of mycobacterial infections: tuberculosis and Mycobacterium other than tuberculosis in dialysis patients. Isr Med Assoc J. 2007;9(6):448–451. [PubMed] [Google Scholar]
  • 25.Centers for Disease Control and Prevention Nontuberculous mycobacterial infections in hemodialysis patients–Louisiana, 1982. MMWR Morb Mortal Wkly Rep. 1983;32(18):244–246. [PubMed] [Google Scholar]
  • 26.Lowry P.W. Mycobacterium chelonae infection among patients receiving high-flux dialysis in a hemodialysis clinic in California. J Infect Dis. 1990;161(1):85–90. doi: 10.1093/infdis/161.1.85. [DOI] [PubMed] [Google Scholar]
  • 27.Bland L.A., Favero M.S., editors. vol. 3. Joint Commission on Accreditation of Healthcare Organizations; Oakbrook Terrace: 1989. (Microbial contamination control strategies for hemodialysis systems. Plant, Technology, and Safety Management Series). [Google Scholar]
  • 28.Favero M.S. Microbial contamination of renal dialysis systems and associated health risks. Trans Am Soc Artif Intern Organs. 1974;20A:175–183. [PubMed] [Google Scholar]
  • 29.Carson L.A. Factors affecting endotoxin levels in fluids associated with hemodialysis procedures. Prog Clin Biol Res. 1987;231:223–234. [PubMed] [Google Scholar]
  • 30.AAMI . Association for the Advancement for Medical Instrumentation; Arlington, VA: 2008. American National Standard: Reuse of Hemodialyzers. [Google Scholar]
  • 31.AAMI . Association for the Advancement of Medical Instrumentation; Arlington, VA: 2014. Recommended Practice: Water for hemodialysis and related therapies. [Google Scholar]
  • 32.AAMI . Association for the Advancement of Medical Instrumentation; Arlington, VA: 2014. Guidance for the preparation and quality management of fluids for hemodialysis and related therapies. [Google Scholar]
  • 33.AAMI . Association for the Advancement of Medical Instrumentation; Arlington, VA: 2014. Quality of dialysis fluids for hemodialysis and related therapies. [Google Scholar]
  • 34.Centers for Medicare & Medicaid Services Medicare and Medicaid programs; conditions for coverage for end-stage renal disease facilities. Final rule. Fed Regist. 2008;73(73):20369–20484. [PubMed] [Google Scholar]
  • 35.Stamm J.M., Engelhard W.E., Parsons J.E. Microbiological study of water-softener resins. Applied Microbiology. 1969;18:376–386. doi: 10.1128/am.18.3.376-386.1969. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 36.Anderson R.L., Holland B.W., Carr J.K. Effect of disinfectants on pseudomonads colonized on the interior surfaces of PVC Pipes. Am J Public Health. 1990;80:17–21. doi: 10.2105/ajph.80.1.17. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 37.AAMI . Association for the Advancement of Medical Instrumentation; Arlington, VA: 2014. American National Standard: Water treatment equipment for hemodialysis and related therapies. [Google Scholar]
  • 38.Arduino M.J. Microbiologic quality of water used for hemodialysis. Contemp Dial Nephrol. 1996;17:17–19. [Google Scholar]
  • 39.Arduino M.J. What’s new in water treatment standards for hemodialysis. Contemp Dial Nephrol. 1997;18:21–24. [Google Scholar]
  • 40.Petersen N.J. Pyrogenic reactions from inadequate disinfection of a dialysis fluid distribution system. Dialysis Transplant. 1978;7:52–57. [Google Scholar]
  • 41.Jochimsen E.M. A cluster of bloodstream infections and pyrogenic reactions among hemodialysis patients traced to dialysis machine waste-handling option units. Am J Nephrol. 1998;18(6):485–489. doi: 10.1159/000013392. [DOI] [PubMed] [Google Scholar]
  • 42.Wang S.A. An outbreak of gram-negative bacteremia in hemodialysis patients traced to hemodialysis machine waste drain ports. Infect Control Hosp Epidemiol. 1999;20(11):746–751. doi: 10.1086/501576. [DOI] [PubMed] [Google Scholar]
  • 43.Rao C.Y. CDC; Atlanta, GA: 2006. An Outbreak of Phialemonium Mold Infections in Hemodialysis Patients: When Purified Water Is Not So Pure – Illinois, 2005, 55th Annual Epidemic Intelligence Service Conference. [Google Scholar]
  • 44.Favero M.S., P.N., Boyer K.M., Carson L.A., Bond W.W. Microbial contamination of renal dialysis systems and associated health risks. Trans Am Soc Artif Intern Organs. 1974;20A:175–183. [PubMed] [Google Scholar]
  • 45.Centers for Disease Control and Prevention . Pyrogenic reactions and gram-negative bacteremia in a hemodialysis center. In: Services H.a.H., editor. Epidemiologic Investigation Report. Department of Health and Human Services; Atlanta: 1991. [Google Scholar]
  • 46.Nguyen D.B. A large outbreak of hepatitis C virus infections in a hemodialysis clinic. Infect Control Hosp Epidemiol. 2016;37(2):125–133. doi: 10.1017/ice.2015.247. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 47.Novosad S. 2017. Unusual Source of Gram-negative Bloodstream Infections in Hemodialysis Patients, in SHEA Spring 2017 Conference. St. Louis, MO. [Google Scholar]
  • 48.Tokars J.I. National surveillance of dialysis-associated diseases in the United States, 2000. Semin Dial. 2002;15(3):162–171. doi: 10.1046/j.1525-139x.2002.00051.x. [DOI] [PubMed] [Google Scholar]
  • 49.Finelli L. National surveillance of dialysis-associated diseases in the United States, 2002. Semin Dial. 2005;18(1):52–61. doi: 10.1111/j.1525-139X.2005.18108.x. [DOI] [PubMed] [Google Scholar]
  • 50.Toniolo Ado R. Evaluation of the effectiveness of manual and automated dialyzers reprocessing after multiple reuses. Am J Infect Control. 2016;44(6):719–720. doi: 10.1016/j.ajic.2015.12.035. [DOI] [PubMed] [Google Scholar]
  • 51.Prasad N., Jha V. Hemodialysis in Asia. Kidney Dis (Basel) 2015;1(3):165–177. doi: 10.1159/000441816. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 52.Edens C. Hemodialyzer reuse and gram-negative bloodstream infections. Am J Kidney Dis. 2017;69(6):726–733. doi: 10.1053/j.ajkd.2016.09.022. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 53.AAMI . Association for the Advancement of Medical Instrumentation; Arlington, VA: 1986. Reuse of hemodiayzers. [Google Scholar]
  • 54.Bland L. Hemodialyzer reuse: practices in the United States and implication for infection control. Trans Am Soc Artif Intern Organs. 1985;31:556–559. [PubMed] [Google Scholar]
  • 55.Arduino M.J. How should dialyzers be reprocessed? Seminars in Dialysis. 1998;11(5):282–284. [Google Scholar]
  • 56.Favero M.S. Distinguishing between high-level disinfection, reprocessing, and sterilization. In: Easterling R.E., editor. Reuse of Disposables: Implications for Quality Health Care and Cost Containment. AAMI; Arlington, VA: 1983. pp. 19–23. [Google Scholar]
  • 57.Oyong K. Outbreak of bloodstream infections associated with multiuse dialyzers containing O-rings. Infect Control Hosp Epidemiol. 2014;35(1):89–91. doi: 10.1086/674399. [DOI] [PubMed] [Google Scholar]
  • 58.Rosenberg, J. Primary Bloodstream Infections Associated with Dialyzer Reuse in California Dialysis Centers in IDSA 2005; October 6-9, 2005; San Francisco, CA. 2005: IDSA 2005; October 6-9, 2005; San Francisco, CA.
  • 59.Welbel S.F. An outbreak of gram-negative bloodstream infections in chronic hemodialysis patients. Am J Nephrol. 1995;15(1):1–4. doi: 10.1159/000168793. [DOI] [PubMed] [Google Scholar]
  • 60.Bland L.A. Potential bacteriologic and endotoxin hazards associated with liquid bicarbonate concentrate. ASAIO Trans. 1987;33(3):542–545. [PubMed] [Google Scholar]
  • 61.Tokars J.I. US Department of Health and Human Services; Altanta, GA: 1998. National surveillance of dialysis-associated diseases in the United States, 1995. [DOI] [PubMed] [Google Scholar]
  • 62.Petersen N.J. Microbiologic evaluation of a new glutaraldehyde-based disinfectant for hemodialysis systems. Trans Am Soc Artif Intern Organs. 1982;28:287–290. [PubMed] [Google Scholar]
  • 63.Townsend T.R., Wee S.B., Bartlett J. Disinfection of hemodialysis machines. Dialysis and Transplantation. 1985;14:274–287. [Google Scholar]
  • 64.Centers for Disease Control and Prevention Occupational exposures to formaldehyde in dialysis units. MMWR Morb Mortal Wkly Rep. 1986;35(24):399–401. [PubMed] [Google Scholar]
  • 65.AAMI . Association for the Advancement of Medical Instrumentation; Arlington, VA: 2004. Recommended Practice: Dialysate for Hemodialysis. [Google Scholar]
  • 66.AAMI . Association for the Advancement for Medical Instrumentation; Arlington, VA: 2006. American National Standard: Water Treatment Equipment for Hemodialysis Applications. [Google Scholar]
  • 67.Favero M.S., Petersen N.J. Microbiologic guidelines for hemodialysis systems. Dialysis and Transplantation. 1977;6:34–36. [Google Scholar]
  • 68.Bommer J., Jaber B.L. Ultrapure dialysate: facts and myths. Semin Dial. 2006;19(2):115–119. doi: 10.1111/j.1525-139X.2006.00136.x. [DOI] [PubMed] [Google Scholar]
  • 69.Ward R.A. Ultrapure dialysate. Semin Dial. 2004;17(6):489–497. doi: 10.1111/j.0894-0959.2004.17617.x. [DOI] [PubMed] [Google Scholar]
  • 70.Izuhara Y. Ultrapure dialysate decreases plasma pentosidine, a marker of “carbonyl stress”. Am J Kidney Dis. 2004;43(6):1024–1029. doi: 10.1053/j.ajkd.2004.02.015. [DOI] [PubMed] [Google Scholar]
  • 71.Johnson D.W., Pollock C.A., Macdougall I.C. Erythropoiesis-stimulating agent hyporesponsiveness. Nephrology (Carlton) 2007;12(4):321–330. doi: 10.1111/j.1440-1797.2007.00810.x. [DOI] [PubMed] [Google Scholar]
  • 72.Go I. The effect of ultrapure dialysate on improving renal anemia. Osaka City Med J. 2007;53(1):17–23. [PubMed] [Google Scholar]
  • 73.Lacson E., Jr., Levin N.W. C-reactive protein and end-stage renal disease. Semin Dial. 2004;17(6):438–448. doi: 10.1111/j.0894-0959.2004.17604.x. [DOI] [PubMed] [Google Scholar]
  • 74.Sitter T., Bergner A., Schiffl H. Dialysate related cytokine induction and response to recombinant human erythropoietin in haemodialysis patients. Nephrol Dial Transplant. 2000;15(8):1207–1211. doi: 10.1093/ndt/15.8.1207. [DOI] [PubMed] [Google Scholar]
  • 75.Schiffl H. Effects of ultrapure dialysis fluid on nutritional status and inflammatory parameters. Nephrol Dial Transplant. 2001;16(9):1863–1869. doi: 10.1093/ndt/16.9.1863. [DOI] [PubMed] [Google Scholar]
  • 76.Hsu P.Y. Ultrapure dialysate improves iron utilization and erythropoietin response in chronic hemodialysis patients—a prospective cross-over study. J Nephrol. 2004;17(5):693–700. [PubMed] [Google Scholar]
  • 77.Furuya R. Ultrapure dialysate reduces plasma levels of beta2-microglobulin and pentosidine in hemodialysis patients. Blood Purif. 2005;23(4):311–316. doi: 10.1159/000086554. [DOI] [PubMed] [Google Scholar]
  • 78.Schiffl H., Lang S.M., Fischer R. Ultrapure dialysis fluid slows loss of residual renal function in new dialysis patients. Nephrol Dial Transplant. 2002;17(10):1814–1818. doi: 10.1093/ndt/17.10.1814. [DOI] [PubMed] [Google Scholar]
  • 79.Schiffl H., Wendinger H., Lang S.M. Ultrapure dialysis fluid and response to hepatitis B vaccine. Nephron. 2002;91(3):530–531. doi: 10.1159/000064303. [DOI] [PubMed] [Google Scholar]
  • 80.Schiffl H., Lang S.M., Bergner A. Ultrapure dialysate reduces dose of recombinant human erythropoietin. Nephron. 1999;83(3):278–279. doi: 10.1159/000045525. [DOI] [PubMed] [Google Scholar]
  • 81.Tielemans C. Effects of ultrapure and non-sterile dialysate on the inflammatory response during in vitro hemodialysis. Kidney Int. 1996;49(1):236–243. doi: 10.1038/ki.1996.33. [DOI] [PubMed] [Google Scholar]
  • 82.Baz M. Using ultrapure water in hemodialysis delays carpal tunnel syndrome. Int J Artif Organs. 1991;14(11):681–685. [PubMed] [Google Scholar]
  • 83.Upadhyay A., Jaber B.L. We use impure water to make dialysate for hemodialysis. Semin Dial. 2016;29(4):297–299. doi: 10.1111/sdi.12493. [DOI] [PubMed] [Google Scholar]
  • 84.Upadhyay A., Susantitaphong P., Jaber B.L. Ultrapure versus standard dialysate: a cost-benefit analysis. Semin Dial. 2017 doi: 10.1111/sdi.12618. [DOI] [PubMed] [Google Scholar]
  • 85.Hasegawa T. Dialysis fluid endotoxin level and mortality in maintenance hemodialysis: a nationwide cohort study. Am J Kidney Dis. 2015;65(6):899–904. doi: 10.1053/j.ajkd.2014.12.009. [DOI] [PubMed] [Google Scholar]
  • 86.AAMI . Association for the Advancement of Medical Instrumentation; Arlington, VA: 2014. Water testing methodologies. [Google Scholar]
  • 87.Pegues D.A. A prospective study of pyrogenic reactions in hemodialysis patients using bicarbonate dialysis fluids filtered to remove bacteria and endotoxin. J Am Soc Nephrol. 1992;3(4):1002–1007. doi: 10.1681/ASN.V341002. [DOI] [PubMed] [Google Scholar]
  • 88.Alter M.J. National surveillance of dialysis-associated diseases in the United States, 1989. ASAIO Trans. 1991;37(2):97–109. [PubMed] [Google Scholar]
  • 89.Tokars J.I. National surveillance of dialysis associated diseases in the United States–1994. ASAIO J. 1997;43(1):108–119. [PubMed] [Google Scholar]
  • 90.Tokars J.I. National surveillance of dialysis associated diseases in the United States, 1993. ASAIO J. 1996;42(3):219–229. [PubMed] [Google Scholar]
  • 91.Tokars J.I. National surveillance of dialysis associated diseases in the United States, 1992. ASAIO J. 1994;40(4):1020–1031. [PubMed] [Google Scholar]
  • 92.Tokars J.I. National surveillance of dialysis associated diseases in the United States, 1991. ASAIO J. 1993;39(4):966–975. [PubMed] [Google Scholar]
  • 93.Tokars J.I. National surveillance of hemodialysis associated diseases in the United States, 1990. ASAIO J. 1993;39(1):71–80. [PubMed] [Google Scholar]
  • 94.Alter M.J. National surveillance of dialysis-associated diseases in the United States, 1987. ASAIO Trans. 1989;35(4):820–831. [PubMed] [Google Scholar]
  • 95.Tokars J.I. National surveillance of dialysis-associated diseases in the United States, 2001. Semin Dial. 2004;17(4):310–319. doi: 10.1111/j.0894-0959.2004.17339.x. [DOI] [PubMed] [Google Scholar]
  • 96.Tokars J.I. National surveillance of dialysis associated diseases in the United States, 1995. ASAIO J. 1998;44(1):98–107. doi: 10.1097/00002480-199801000-00019. [DOI] [PubMed] [Google Scholar]
  • 97.Tokars J.I. National surveillance of dialysis-associated diseases in the United States, 1997. Semin Dial. 2000;13(2):75–85. doi: 10.1046/j.1525-139x.2000.00026.x. [DOI] [PubMed] [Google Scholar]
  • 98.David S. Production of platelet activating factor by human neutrophils after backfiltration of endotoxin contaminated dialysate. ASAIO J. 1993;39(3) M773–7. [PubMed] [Google Scholar]
  • 99.Laude-Sharp M. Induction of IL-1 during hemodialysis: transmembrane passage of intact endotoxins (LPS) Kidney Int. 1990;38(6):1089–1094. doi: 10.1038/ki.1990.317. [DOI] [PubMed] [Google Scholar]
  • 100.Yamagami S. Detection of endotoxin antibody in long-term dialysis patients. Int J Artif Organs. 1990;13(4):205–210. [PubMed] [Google Scholar]
  • 101.Gazenfield-Gazit E., Eliahou H.E. Endotoxin antibodies in patients on maintenance hemodialysis. Isr J Med Sci. 1969;5(5):1032–1036. [PubMed] [Google Scholar]
  • 102.Sundaram S. Transmembrane passage of cytokine-inducing bacterial products across new and reprocessed polysulfone dialyzers. J Am Soc Nephrol. 1996;7(10):2183–2191. doi: 10.1681/ASN.V7102183. [DOI] [PubMed] [Google Scholar]
  • 103.Arduino M.J. The effects of endotoxin-contaminated dialysate and polysulfone or cellulosic membranes on the release of TNF alpha during simulated dialysis. Artif Organs. 1995;19(9):880–886. doi: 10.1111/j.1525-1594.1995.tb02446.x. [DOI] [PubMed] [Google Scholar]
  • 104.Henderson L.W. Haemodialysis hypotension: the interleukin hypothesis. Blood Purification. 1993;1:3–8. [Google Scholar]
  • 105.Port F.K. The role of dialysate in the stimulation of interleukin-1 production during clinical hemodialysis. Am J Kidney Dis. 1987;10(2):118–122. doi: 10.1016/s0272-6386(87)80043-4. [DOI] [PubMed] [Google Scholar]
  • 106.Kantor R.J. Outbreak of pyrogenic reactions at a dialysis center. Association with infusion of heparinized saline solution. Am J Med. 1983;74(3):449–456. doi: 10.1016/0002-9343(83)90978-6. [DOI] [PubMed] [Google Scholar]
  • 107.Oliver J.C. Bacteria and endotoxin removal from bicarbonate dialysis fluids for use in conventional, high-efficiency, and high-flux hemodialysis. Artif Organs. 1992;16(2):141–145. doi: 10.1111/j.1525-1594.1992.tb00284.x. [DOI] [PubMed] [Google Scholar]
  • 108.Favero M.S., Bolyard E.A. Microbiological considerations. Disinfection and sterilization strategies and the potential for airborne transmission of bloodborne pathogens. Surg Clin North Am. 1995;75(6):1071–1089. doi: 10.1016/s0039-6109(16)46782-4. [DOI] [PubMed] [Google Scholar]
  • 109.Favero M.S., Bond, W.W. Chemical disinfection of medical and surgical materials. In: Block S.S., editor. Disinfection, Sterilization, and Preservation. 4th ed. Lea & Febiger; Philadelphia: 1991. pp. 617–641. [Google Scholar]
  • 110.Sehulster L., Chinn R.Y. Guidelines for environmental infection control in health-care facilities. Recommendations of CDC and the Healthcare Infection Control Practices Advisory Committee (HICPAC) MMWR Recomm Rep. 2003;52(RR-10):1–42. [PubMed] [Google Scholar]
  • 111.Facility Guidelines Institute . 2014. Guidelines for Design and Construction of Hospitals and Outpatient Facilities. [Google Scholar]
  • 112.Bergervoet P.W. Application of the forensic Luminol for blood in infection control. J Hosp Infect. 2008;68(4):329–333. doi: 10.1016/j.jhin.2008.01.026. [DOI] [PubMed] [Google Scholar]
  • 113.Bloembergen W.E., Port F.K. Epidemiological perspective on infections in chronic dialysis patients. Adv Ren Replace Ther. 1996;3(3):201–207. doi: 10.1016/s1073-4449(96)80022-7. [DOI] [PubMed] [Google Scholar]
  • 114.Dobkin J.F., Miller M.H., Steigbigel N.H. Septicemia in patients on chronic hemodialysis. Ann Intern Med. 1978;88(1):28–33. doi: 10.7326/0003-4819-88-1-28. [DOI] [PubMed] [Google Scholar]
  • 115.Hoen B. EPIBACDIAL: a multicenter prospective study of risk factors for bacteremia in chronic hemodialysis patients. J Am Soc Nephrol. 1998;9(5):869–876. doi: 10.1681/ASN.V95869. [DOI] [PubMed] [Google Scholar]
  • 116.Bonomo R.A. Risk factors associated with permanent access-site infections in chronic hemodialysis patients. Infect Control Hosp Epidemiol. 1997;18(11):757–761. doi: 10.1086/647530. [DOI] [PubMed] [Google Scholar]
  • 117.Kaplowitz L.G. A prospective study of infections in hemodialysis patients: patient hygiene and other risk factors for infection. Infect Control Hosp Epidemiol. 1988;9(12):534–541. doi: 10.1086/645772. [DOI] [PubMed] [Google Scholar]
  • 118.Keane W.F., Shapiro F.L., Raij L. Incidence and type of infections occurring in 445 chronic hemodialysis patients. Trans Am Soc Artif Intern Organs. 1977;23:41–47. doi: 10.1097/00002480-197700230-00012. [DOI] [PubMed] [Google Scholar]
  • 119.Kessler M. Bacteremia in patients on chronic hemodialysis. A multicenter prospective survey. Nephron. 1993;64(1):95–100. doi: 10.1159/000187285. [DOI] [PubMed] [Google Scholar]
  • 120.Stevenson K.B. Epidemiology of hemodialysis vascular access infections from longitudinal infection surveillance data: predicting the impact of NKF-DOQI clinical practice guidelines for vascular access. Am J Kidney Dis. 2002;39(3):549–555. doi: 10.1053/ajkd.2002.31405. [DOI] [PubMed] [Google Scholar]
  • 121.Tokars J.I. A prospective study of vascular access infections at seven outpatient hemodialysis centers. Am J Kidney Dis. 2001;37(6):1232–1240. doi: 10.1053/ajkd.2001.24527. [DOI] [PubMed] [Google Scholar]
  • 122.Tokars J.I., Miller E.R., Stein G. New national surveillance system for hemodialysis-associated infections: initial results. Am J Infect Control. 2002;30(5):288–295. doi: 10.1067/mic.2002.120904. [DOI] [PubMed] [Google Scholar]
  • 123.Ponce P., et al. A prospective study on incidence of bacterial infections in portuguese dialysis units. Nephron Clin Pract. 107(4): c133–8. [DOI] [PubMed]
  • 124.Tokars J.I. Bloodstream infections in hemodialysis patients: getting some deserved attention. Infect Control Hosp Epidemiol. 2002;23(12):713–715. doi: 10.1086/501998. [DOI] [PubMed] [Google Scholar]
  • 125.Centers for Disease Control and Prevention. Dialysis Event Protocol. 4/25/2016; Available from: http://www.cdc.gov/nhsn/PDFs/pscManual/8pscDialysisEventcurrent.pdf.
  • 126.Patel P.R. Dialysis event surveillance report: national healthcare safety network data summary, January 2007 through April 2011. Am J Infect Control. 2016;44(8):944–947. doi: 10.1016/j.ajic.2016.02.009. [DOI] [PubMed] [Google Scholar]
  • 127.Nguyen D.B. National healthcare safety network (NHSN) dialysis event surveillance report for 2014. Clin J Am Soc Nephrol. 2017;12(7):1139–1146. doi: 10.2215/CJN.11411116. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 128.Padberg F.T., Jr., Lee B.C., Curl G.R. Hemoaccess site infection. Surg Gynecol Obstet. 1992;174(2):103–108. [PubMed] [Google Scholar]
  • 129.Klevens R.M., Tokars J.I., Andrus M. Electronic reporting of infections associated with hemodialysis. Nephrol News Issues. 2005;19(7):37–38. 43. [PubMed] [Google Scholar]
  • 130.Klevens R.M. Dialysis surveillance report: national healthcare safety network (NHSN)-data summary for 2006. Seminars in Dialysis. 2008;21(1):24–28. doi: 10.1111/j.1525-139X.2007.00379.x. [DOI] [PubMed] [Google Scholar]
  • 131.Thomson P.C. Vascular access in haemodialysis patients: a modifiable risk factor for bacteraemia and death. Qjm. 2007;100(7):415–422. doi: 10.1093/qjmed/hcm040. [DOI] [PubMed] [Google Scholar]
  • 132.Lafrance J.P. Vascular access-related infections: definitions, incidence rates, and risk factors. Am J Kidney Dis. 2008 doi: 10.1053/j.ajkd.2008.06.014. [DOI] [PubMed] [Google Scholar]
  • 133.Albers F.J. Clinical considerations in hemodialysis access infection. Adv Ren Replace Ther. 1996;3(3):208–217. doi: 10.1016/s1073-4449(96)80023-9. [DOI] [PubMed] [Google Scholar]
  • 134.Powe N.R. Septicemia in dialysis patients: incidence, risk factors, and prognosis. Kidney Int. 1999;55(3):1081–1090. doi: 10.1046/j.1523-1755.1999.0550031081.x. [DOI] [PubMed] [Google Scholar]
  • 135.Fan P.Y., Schwab S.J. Vascular access: concepts for the 1990s. J Am Soc Nephrol. 1992;3(1):1–11. doi: 10.1681/ASN.V311. [DOI] [PubMed] [Google Scholar]
  • 136.Gulati S. Role of vascular access as a risk factor for infections in hemodialysis. Ren Fail. 2003;25(6):967–973. doi: 10.1081/jdi-120026031. [DOI] [PubMed] [Google Scholar]
  • 137.NKF, NKF-DOQI clinical practice guidelines for vascular access National Kidney Foundation-Dialysis Outcomes Quality Initiative. Am J Kidney Dis. 1997;30(4 suppl 3):S150–S191. [PubMed] [Google Scholar]
  • 138.NKF, III NKF-K/DOQI Clinical Practice Guidelines for Vascular Access: update 2000. Am J Kidney Dis. 2001;37(1 suppl 1):S137–S181. doi: 10.1016/s0272-6386(01)70007-8. [DOI] [PubMed] [Google Scholar]
  • 139.NKF Clinical practice recommendation 8: vascular access in pediatric patients. Am J Kidney Dis. 2006;48(suppl 1):S274–S276. doi: 10.1053/j.ajkd.2006.04.049. [DOI] [PubMed] [Google Scholar]
  • 140.NKF Clinical practice guidelines for vascular access. Am J Kidney Dis. 2006;48(suppl 1):S248–S273. doi: 10.1053/j.ajkd.2006.04.040. [DOI] [PubMed] [Google Scholar]
  • 141.NKF Clinical practice guidelines for vascular access. Am J Kidney Dis. 2006;48(suppl 1):S176–S247. doi: 10.1053/j.ajkd.2006.04.029. [DOI] [PubMed] [Google Scholar]
  • 142.Pisoni R.L. Trends in US vascular access use, patient preferences, and related practices: an update from the US DOPPS practice monitor with international comparisons. Am J Kidney Dis. 2015;65(6):905–915. doi: 10.1053/j.ajkd.2014.12.014. [DOI] [PubMed] [Google Scholar]
  • 143.Arnow P.M. An outbreak of bloodstream infections arising from hemodialysis equipment. J Infect Dis. 1998;178(3):783–791. doi: 10.1086/515363. [DOI] [PubMed] [Google Scholar]
  • 144.Block C. Outbreak of bloodstream infections associated with dialysis machine waste ports in a hemodialysis facility. Eur J Clin Microbiol Infect Dis. 1999;18(10):723–725. doi: 10.1007/s100960050385. [DOI] [PubMed] [Google Scholar]
  • 145.Centers for Disease Control and Prevention Outbreaks of gram-negative bacterial bloodstream infections traced to probable contamination of hemodialysis machines–Canada, 1995; United States, 1997; and Israel, 1997. MMWR Morb Mortal Wkly Rep. 1998;47(3):55–59. [PubMed] [Google Scholar]
  • 146.Tokars J.I., A.M., Arduino M.J., editors. Nosocomial infections in hemodialysis units: strategies for control. The Principles and Practices of Nephrology. Mosby; St. Louis: 1995. pp. 337–357. [Google Scholar]
  • 147.Grohskopf L.A. Serratia liquefaciens bloodstream infections from contamination of epoetin alfa at a hemodialysis center. N Engl J Med. 2001;344(20):1491–1497. doi: 10.1056/NEJM200105173442001. [DOI] [PubMed] [Google Scholar]
  • 148.Centers for Disease Control and Prevention Guidelines for the prevention of intravascular catheter-related infections. MMWR Morb Mortal Wkly Rep. 2002;51(RR-10):1–29. [PubMed] [Google Scholar]
  • 149.O’Grady N.P. Guidelines for the prevention of intravascular catheter-related infections. Clin Infect Dis. 2011;52(9) doi: 10.1093/cid/cir257. e162–93. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 150.Patel P.R. Bloodstream infection rates in outpatient hemodialysis facilities participating in a collaborative prevention effort: a quality improvement report. Am J Kidney Dis. 2013;62(2):322–330. doi: 10.1053/j.ajkd.2013.03.011. [DOI] [PubMed] [Google Scholar]
  • 151.Centers for Disease Control and Prevention Reducing bloodstream infections in an outpatient hemodialysis center–New Jersey, 2008-2011. MMWR Morb Mortal Wkly Rep. 2012;61(10):169–173. [PubMed] [Google Scholar]
  • 152.Dinwiddie L. Cleansing agents used for hemodialysis catheter care. Nephrol Nurs J. 2002;29(6):599–613. [PubMed] [Google Scholar]
  • 153.Yahav D. Antimicrobial lock solutions for the prevention of infections associated with intravascular catheters in patients undergoing hemodialysis: systematic review and meta-analysis of randomized, controlled trials. Clin Infect Dis. 2008;47(1):83–93. doi: 10.1086/588667. [DOI] [PubMed] [Google Scholar]
  • 154.Jaffer Y. A meta-analysis of hemodialysis catheter locking solutions in the prevention of catheter-related infection. Am J Kidney Dis. 2008;51(2):233–241. doi: 10.1053/j.ajkd.2007.10.038. [DOI] [PubMed] [Google Scholar]
  • 155.Berns J.S., Tokars J.I. Preventing bacterial infections and antimicrobial resistance in dialysis patients. Am J Kidney Dis. 2002;40(5):886–898. doi: 10.1053/ajkd.2002.36332. [DOI] [PubMed] [Google Scholar]
  • 156.Mermel L.A. Prevention of intravascular catheter infections–insights and prospects for hemodialysis catheters. Nephrologie. 2001;22(8):449–451. [PubMed] [Google Scholar]
  • 157.Mermel L.A. Guidelines for the management of intravascular catheter-related infections. Clin Infect Dis. 2001;32(9):1249–1272. doi: 10.1086/320001. [DOI] [PubMed] [Google Scholar]
  • 158.Camins B.C. A crossover intervention trial evaluating the efficacy of a chlorhexidine-impregnated sponge in reducing catheter-related bloodstream infections among patients undergoing hemodialysis. Infect Control Hosp Epidemiol. 2010;31(11):1118–1123. doi: 10.1086/657075. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 159.Onder A.M. Controlling exit site infections: does it decrease the incidence of catheter-related bacteremia in children on chronic hemodialysis? Hemodial Int. 2009;13(1):11–18. doi: 10.1111/j.1542-4758.2009.00348.x. [DOI] [PubMed] [Google Scholar]
  • 160.Hymes J.L. Dialysis catheter-related bloodstream infections: a cluster-randomized trial of the clearguard hd antimicrobial barrier cap. Am J Kidney Dis. 2017;69(2):220–227. doi: 10.1053/j.ajkd.2016.09.014. [DOI] [PubMed] [Google Scholar]
  • 161.Brunelli S.M. Use of the Tego needlefree connector is associated with reduced incidence of catheter-related bloodstream infections in hemodialysis patients. Int J Nephrol Renovasc Dis. 2014;7:131–139. doi: 10.2147/IJNRD.S59937. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 162.Centers for Disease Control and Prevention Recommendations for preventing transmission of infections among chronic hemodialysis patients. MMWR Recomm Rep. 2001;50(RR-5):1–43. [PubMed] [Google Scholar]
  • 163.Centers for Disease Control and Prevention Infection control requirements for dialysis facilities and clarification regarding guidance on parenteral medication vials. MMWR Morb Mortal Wkly Rep. 2008;57(32):875–876. [PubMed] [Google Scholar]
  • 164.United States Renal Data System . National Institutes of Health, National Institute of Diabetes and Digestive and Kidney Diseases; Bethesda, MD: 2008. USRDS 2008 Annual Data Report: Atlas of Chronic Kidney Disease and End-Stage Renal Disease in the United States. [Google Scholar]
  • 165.Berman S.J. Burden of infection in patients with end-stage renal disease requiring long-term dialysis. Clin Infect Dis. 2004;39(12):1747–1753. doi: 10.1086/424516. [DOI] [PubMed] [Google Scholar]
  • 166.Slinin Y., Foley R.N., Collins A.J. Clinical epidemiology of pneumonia in hemodialysis patients: the USRDS waves 1, 3, and 4 study. Kidney Int. 2006;70(6):1135–1141. doi: 10.1038/sj.ki.5001714. [DOI] [PubMed] [Google Scholar]
  • 167.Guo H. Pneumonia in incident dialysis patients–the United States Renal Data System. Nephrol Dial Transplant. 2008;23(2):680–686. doi: 10.1093/ndt/gfm474. [DOI] [PubMed] [Google Scholar]
  • 168.Centers for Disease Control and Prevention Use of 13-valent pneumococcal conjugate vaccine and 23-valent pneumococcal polysaccharide vaccine for adults with immunocompromising conditions: recommendations of the Advisory Committee on Immunization Practices (ACIP) MMWR Morb Mortal Wkly Rep. 2012;61(40):816–819. [PubMed] [Google Scholar]
  • 169.Grohskopf L.A. Prevention and control of seasonal influenza with vaccines. MMWR Recomm Rep. 2016;65(5):1–54. doi: 10.15585/mmwr.rr6505a1. [DOI] [PubMed] [Google Scholar]
  • 170.Gilbertson D.T. Influenza vaccine delivery and effectiveness in end-stage renal disease. Kidney Int. 2003;63(2):738–743. doi: 10.1046/j.1523-1755.2003.00787.x. [DOI] [PubMed] [Google Scholar]
  • 171.Van Buynder P.G. Healthcare worker influenza immunization vaccinate or mask policy: strategies for cost effective implementation and subsequent reductions in staff absenteeism due to illness. Vaccine. 2015;33(13):1625–1628. doi: 10.1016/j.vaccine.2015.01.048. [DOI] [PubMed] [Google Scholar]
  • 172.Saxen H., Virtanen M. Randomized, placebo-controlled double blind study on the efficacy of influenza immunization on absenteeism of health care workers. Pediatr Infect Dis J. 1999;18(9):779–783. doi: 10.1097/00006454-199909000-00007. [DOI] [PubMed] [Google Scholar]
  • 173.Salgado C.D. Preventing nosocomial influenza by improving the vaccine acceptance rate of clinicians. Infect Control Hosp Epidemiol. 2004;25(11):923–928. doi: 10.1086/502321. [DOI] [PubMed] [Google Scholar]
  • 174.Lynch J.R. Correlates of change in health care worker seasonal influenza vaccination rates among dialysis facilities. Am J Infect Control. 2015;43(4):409–411. doi: 10.1016/j.ajic.2014.12.011. [DOI] [PubMed] [Google Scholar]
  • 175.Jensen P.A. Guidelines for preventing the transmission of Mycobacterium tuberculosis in health-care settings, 2005. MMWR Recomm Rep. 2005;54(RR-17):1–141. [PubMed] [Google Scholar]
  • 176.Centers for Disease Control and Prevention Tuberculosis transmission in a renal dialysis center—Nevada, 2003. MMWR Morb Mortal Wkly Rep. 2004;53(37):873–875. [PubMed] [Google Scholar]
  • 177.Linquist J.A. Tuberculosis exposure of patients and staff in an outpatient hemodialysis unit. Am J Infect Control. 2002;30(5):307–310. doi: 10.1067/mic.2002.123394. [DOI] [PubMed] [Google Scholar]
  • 178.Zaki A.M. Isolation of a novel coronavirus from a man with pneumonia in Saudi Arabia. N Engl J Med. 2012;367(19):1814–1820. doi: 10.1056/NEJMoa1211721. [DOI] [PubMed] [Google Scholar]
  • 179.Kallen A.J., Arduino M.J., Patel P.R. Preventing infections in patients undergoing hemodialysis. Expert Rev Anti Infect Ther. 2010;8(6):643–655. doi: 10.1586/eri.10.47. [DOI] [PubMed] [Google Scholar]
  • 180.Uttley A.H. High-level vancomycin-resistant enterococci causing hospital infections. Epidemiol Infect. 1989;103(1):173–181. doi: 10.1017/s0950268800030478. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 181.Gray J.W., George R.H. Experience of vancomycin-resistant enterococci in a children’s hospital. J Hosp Infect. 2000;45(1):11–18. doi: 10.1053/jhin.1999.0724. [DOI] [PubMed] [Google Scholar]
  • 182.Brady J.P., Snyder J.W., Hasbargen J.A. Vancomycin-resistant enterococcus in end-stage renal disease. Am J Kidney Dis. 1998;32(3):415–418. doi: 10.1053/ajkd.1998.v32.pm9740157. [DOI] [PubMed] [Google Scholar]
  • 183.Roghmann M.C. Colonization with vancomycin-resistant enterococci in chronic hemodialysis patients. Am J Kidney Dis. 1998;32(2):254–257. doi: 10.1053/ajkd.1998.v32.pm9708609. [DOI] [PubMed] [Google Scholar]
  • 184.Fishbane S. Vancomycin-resistant enterococci in hemodialysis patients is related to intravenous vancomycin use. Infect Control Hosp Epidemiol. 1999;20(7):461–462. doi: 10.1086/503139. [DOI] [PubMed] [Google Scholar]
  • 185.Zacharioudakis I.M. Vancomycin-resistant enterococci colonization among dialysis patients: a meta-analysis of prevalence, risk factors, and significance. Am J Kidney Dis. 2015;65(1):88–97. doi: 10.1053/j.ajkd.2014.05.016. [DOI] [PubMed] [Google Scholar]
  • 186.D’Agata E.M. Vancomycin-resistant enterococci among chronic hemodialysis patients: a prospective study of acquisition. Clin Infect Dis. 2001;32(1):23–29. doi: 10.1086/317549. [DOI] [PubMed] [Google Scholar]
  • 187.Dopirak M. Surveillance of hemodialysis-associated primary bloodstream infections: the experience of ten hospital-based centers. Infect Control Hosp Epidemiol. 2002;23(12):721–724. doi: 10.1086/502000. [DOI] [PubMed] [Google Scholar]
  • 188.Taylor G. Prospective surveillance for primary bloodstream infections occurring in Canadian hemodialysis units. Infect Control Hosp Epidemiol. 2002;23(12):716–720. doi: 10.1086/501999. [DOI] [PubMed] [Google Scholar]
  • 189.McDonald L.C., Hageman J.C. Vancomycin intermediate and resistant Staphylococcus aureus. What the nephrologist needs to know. Nephrol News Issues. 2004;18(11):63–64. 66–7, 71–2 passim. [PubMed] [Google Scholar]
  • 190.Fridkin S.K. Vancomycin-intermediate and -resistant Staphylococcus aureus: what the infectious disease specialist needs to know. Clin Infect Dis. 2001;32(1):108–115. doi: 10.1086/317542. [DOI] [PubMed] [Google Scholar]
  • 191.Chang S. Infection with vancomycin-resistant Staphylococcus aureus containing the vanA resistance gene. N Engl J Med. 2003;348(14):1342–1347. doi: 10.1056/NEJMoa025025. [DOI] [PubMed] [Google Scholar]
  • 192.Sievert D.M. Vancomycin-resistant Staphylococcus aureus in the United States, 2002-2006. Clin Infect Dis. 2008;46(5):668–674. doi: 10.1086/527392. [DOI] [PubMed] [Google Scholar]
  • 193.Finks J. Vancomycin-resistant Staphylococcus aureus, Michigan, USA, 2007. Emerg Infect Dis. 2009;15(6):943–945. doi: 10.3201/eid1506.081312. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 194.Zhu W. Vancomycin-resistant Staphylococcus aureus isolates associated with Inc18-like vanA plasmids in Michigan. Antimicrob Agents Chemother. 2008;52(2):452–457. doi: 10.1128/AAC.00908-07. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 195.Walters M.S. Vancomycin-resistant staphylococcus aureus—Delaware, 2015. MMWR Morb Mortal Wkly Rep. 2015;64(37):1056. doi: 10.15585/mmwr.mm6437a6. [DOI] [PubMed] [Google Scholar]
  • 196.Walters M. 2015. Investigation and Control of Vancomycin-resistant Staphylococcus aureus: A Guide for Health Departments and Infection Control Personnel.https://www.cdc.gov/hai/pdfs/vrsa-investigation-guide-05_12_2015.pdf Available from. [Google Scholar]
  • 197.Centers for Disease Control and Prevention Invasive methicillin-resistant Staphylococcus aureus infections among dialysis patients—United States, 2005. MMWR Morb Mortal Wkly Rep. 2007;56(9):197–199. [PubMed] [Google Scholar]
  • 198.Nguyen D.B. Invasive methicillin-resistant Staphylococcus aureus infections among patients on chronic dialysis in the United States, 2005-2011. Clin Infect Dis. 2013;57(10):1393–1400. doi: 10.1093/cid/cit546. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 199.Centers for Disease Control and Prevention . 2015. Active Bacterial Core Surveillance Report, Emerging Infections Program Network, Methicillin-Resistant Staphylococcus aureus, 2015. [Google Scholar]
  • 200.Fluck R. The UK Vascular Access Survey—follow-up data and repeat survey (chapter 5) Nephrol Dial Transplant. 2007;22(suppl 7) doi: 10.1093/ndt/gfm329. vii, 51–7. [DOI] [PubMed] [Google Scholar]
  • 201.Phatharacharukul P. The risks of incident and recurrent clostridium difficile-associated diarrhea in chronic kidney disease and end-stage kidney disease patients: a systematic review and meta-analysis. Dig Dis Sci. 2015;60(10):2913–2922. doi: 10.1007/s10620-015-3714-9. [DOI] [PubMed] [Google Scholar]
  • 202.Tirath A. Clostridium difficile infection in dialysis patients. J Investig Med. 2017;65(2):353–357. doi: 10.1136/jim-2016-000183. [DOI] [PubMed] [Google Scholar]
  • 203.Sheth H. Clostridium difficile infections in outpatient dialysis cohort. Infect Control Hosp Epidemiol. 2010;31(1):89–91. doi: 10.1086/648448. [DOI] [PubMed] [Google Scholar]
  • 204.Evans R. UK renal registry 18th annual report: chapter 12 epidemiology of reported infections amongst patients receiving dialysis for established renal failure in england 2013 to 2014: a joint report from public health england and the UK renal registry. Nephron. 2016;132(suppl 1):279–288. doi: 10.1159/000444826. [DOI] [PubMed] [Google Scholar]
  • 205.See I. Outbreak of clostridium difficile infections at an outpatient hemodialysis facility-michigan, 2012-2013. Infect Control Hosp Epidemiol. 2015;36(8):972–974. doi: 10.1017/ice.2015.90. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 206.Pop-Vicas A. Multidrug-resistant gram-negative bacteria among patients who require chronic hemodialysis. Clin J Am Soc Nephrol. 2008;3(3):752–758. doi: 10.2215/CJN.04651107. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 207.Snyder G.M. Antimicrobial use in outpatient hemodialysis units. Infect Control Hosp Epidemiol. 2013;34(4):349–357. doi: 10.1086/669869. [DOI] [PubMed] [Google Scholar]
  • 208.D’Agata E.M. Antimicrobial use and stewardship programs among dialysis centers. Semin Dial. 2013;26(4):457–464. doi: 10.1111/sdi.12090. [DOI] [PubMed] [Google Scholar]
  • 209.Infectious Diseases Society of America Combating antimicrobial resistance: policy recommendations to save lives. Clin Infect Dis. 2011;52(suppl 5):S397–428. doi: 10.1093/cid/cir153. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 210.Bendinelli M. Blood-borne hepatitis viruses: hepatitis B, C, D, and G viruses and TT virus. In: Specter R.L.H.S., Young S.A., editors. Clinical virology manual. 3rd ed. ASM Press; Washington, DC: 2000. pp. 306–337. [Google Scholar]
  • 211.Alter H. Discovery of non-A, non-B hepatitis and identification of its etiology. Am J Med. 1999;107(6B):16S–20S. doi: 10.1016/s0002-9343(99)00375-7. [DOI] [PubMed] [Google Scholar]
  • 212.Choo Q.L. Isolation of a cDNA clone derived from a blood-borne non-A, non-B viral hepatitis genome. Science. 1989;244(4902):359–362. doi: 10.1126/science.2523562. [DOI] [PubMed] [Google Scholar]
  • 213.Choo Q.L. Identification of the major, parenteral non-A, non-B hepatitis agent (hepatitis C virus) using a recombinant cDNA approach. Semin Liver Dis. 1992;12(3):279–288. doi: 10.1055/s-2007-1007399. [DOI] [PubMed] [Google Scholar]
  • 214.Centers for Disease Control and Prevention Recommendations for prevention and control of hepatitis C virus (HCV) infection and HCV-related chronic disease. MMWR Recomm Rep. 1998;47(RR19):1–39. [PubMed] [Google Scholar]
  • 215.Moyer L.A., Alter M.J. Hepatitis C virus in the hemodialysis setting: a review with recommendations for control. Semin Dial. 1994;7:124–127. [Google Scholar]
  • 216.Favero M.S., Alter M.J. The reemergence of hepatitis B virus infection in hemodialysis centers. Semin Dial. 1996;9:373–374. [Google Scholar]
  • 217.Niu M.T., Coleman P.J., Alter M.J. Multicenter study of hepatitis C virus infection in chronic hemodialysis patients and hemodialysis center staff members. Am J Kidney Dis. 1993;22(4):568–573. doi: 10.1016/s0272-6386(12)80930-9. [DOI] [PubMed] [Google Scholar]
  • 218.Fabrizi F. Incidence of seroconversion for hepatitis C virus in chronic haemodialysis patients: a prospective study. Nephrol Dial Transplant. 1994;9(11):1611–1615. [PubMed] [Google Scholar]
  • 219.Fabrizi F. Hepatitis C virus infection and diabetes mellitus in end-stage renal disease: evidence of a negative association. Int J Artif Organs. 2006;29(7):691–697. doi: 10.1177/039139880602900707. [DOI] [PubMed] [Google Scholar]
  • 220.dos Santos J.P. Impact of dialysis room and reuse strategies on the incidence of hepatitis C virus infection in haemodialysis units. Nephrol Dial Transplant. 1996;11(10):2017–2022. doi: 10.1093/oxfordjournals.ndt.a027090. [DOI] [PubMed] [Google Scholar]
  • 221.Forns X. Incidence and risk factors of hepatitis C virus infection in a haemodialysis unit. Nephrol Dial Transplant. 1997;12(4):736–740. doi: 10.1093/ndt/12.4.736. [DOI] [PubMed] [Google Scholar]
  • 222.McLaughlin K.J. Nosocomial transmission of hepatitis C virus within a British dialysis centre. Nephrol Dial Transplant. 1997;12(2):304–309. doi: 10.1093/ndt/12.2.304. [DOI] [PubMed] [Google Scholar]
  • 223.Petrosillo N. Prevalence of infected patients and understaffing have a role in hepatitis C virus transmission in dialysis. Am J Kidney Dis. 2001;37(5):1004–1010. doi: 10.1016/s0272-6386(05)80017-4. [DOI] [PubMed] [Google Scholar]
  • 224.Bergman S. Hepatitis C infection is acquired pre-ESRD. Am J Kidney Dis. 2005;45(4):684–689. doi: 10.1053/j.ajkd.2004.12.014. [DOI] [PubMed] [Google Scholar]
  • 225.Rahnavardi M., Hosseini Moghaddam S.M., Alavian S.M. Hepatitis C in hemodialysis patients: current global magnitude, natural history, diagnostic difficulties, and preventive measures. Am J Nephrol. 2008;28(4):628–640. doi: 10.1159/000117573. [DOI] [PubMed] [Google Scholar]
  • 226.Saxena A.K., Panhotra B.R., Sundaram D.S. The role the type of vascular access plays in the transmission of hepatitis C virus in a high prevalence hemodialysis unit. J Vasc Access. 2002;3(4):158–163. doi: 10.1177/112972980200300405. [DOI] [PubMed] [Google Scholar]
  • 227.Yakaryilmaz F. Prevalence of occult hepatitis B and hepatitis C virus infections in Turkish hemodialysis patients. Ren Fail. 2006;28(8):729–735. doi: 10.1080/08860220600925602. [DOI] [PubMed] [Google Scholar]
  • 228.El-Reshaid K. Hepatitis C virus infection in patients on maintenance dialysis in kuwait: epidemiological profile and efficacy of prophylaxis. Saudi J Kidney Dis Transpl. 1995;6(2):144–150. [PubMed] [Google Scholar]
  • 229.Gohar S.A. Prevalence of antibodies to hepatitis C virus in hemodialysis patients and renal transplant recipients. J Egypt Public Health Assoc. 1995;70(5-6):465–484. [PubMed] [Google Scholar]
  • 230.Kamili S. Infectivity of hepatitis C virus in plasma after drying and storing at room temperature. Infect Control Hosp Epidemiol. 2007;28(5):519–524. doi: 10.1086/513727. [DOI] [PubMed] [Google Scholar]
  • 231.Paintsil E. Hepatitis C virus maintains infectivity for weeks after drying on inanimate surfaces at room temperature: implications for risks of transmission. J Infect Dis. 2014;209(8):1205–1211. doi: 10.1093/infdis/jit648. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 232.Jeffers L.J. Hepatitis C infection in two urban hemodialysis units. Kidney Int. 1990;38(2):320–322. doi: 10.1038/ki.1990.203. [DOI] [PubMed] [Google Scholar]
  • 233.Carrera F. Prevalence of non-A non-B hepatitis and anti-HCV antibodies in a Portuguese dialysis population. Nephrol Dial Transplant. 1992;7(9):913–916. doi: 10.1093/ndt/7.9.913. [DOI] [PubMed] [Google Scholar]
  • 234.Manescalchi F. Anti-hepatitis C virus epidemiological study in two dialysis centers in Florence. Nephron. 1992;61(3):342–343. doi: 10.1159/000186934. [DOI] [PubMed] [Google Scholar]
  • 235.Schneeberger P.M. The prevalence and incidence of hepatitis C virus infections among dialysis patients in the Netherlands: a nationwide prospective study. J Infect Dis. 2000;182(5):1291–1299. doi: 10.1086/315869. [DOI] [PubMed] [Google Scholar]
  • 236.Sivapalasingam S. High prevalence of hepatitis C infection among patients receiving hemodialysis at an urban dialysis center. Infect Control Hosp Epidemiol. 2002;23(6):319–324. doi: 10.1086/502058. [DOI] [PubMed] [Google Scholar]
  • 237.Dussol B. Hepatitis C virus infection among chronic dialysis patients in the south of France: a collaborative study. Am J Kidney Dis. 1995;25(3):399–404. doi: 10.1016/0272-6386(95)90100-0. [DOI] [PubMed] [Google Scholar]
  • 238.Selgas R. Prevalence of hepatitis C antibodies (HCV) in a dialysis population at one center. Perit Dial Int. 1992;12(1):28–30. [PubMed] [Google Scholar]
  • 239.Thompson N.D. Nonhospital health care-associated hepatitis B and C virus transmission: United States, 1998-2008. Ann Intern Med. 2009;150(1):33–39. doi: 10.7326/0003-4819-150-1-200901060-00007. [DOI] [PubMed] [Google Scholar]
  • 240.Shimokura G. Patient-care practices associated with an increased prevalence of hepatitis C virus infection among chronic hemodialysis patients. Infect Control Hosp Epidemiol. 2011;32(5):415–424. doi: 10.1086/659407. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 241.Thompson N.D. Hepatitis C virus transmission in the hemodialysis setting: importance of infection control practices and aseptic technique. Infect Control Hosp Epidemiol. 2009;30(9):900–903. doi: 10.1086/605472. [DOI] [PubMed] [Google Scholar]
  • 242.Halleck R. Hepatitis C transmission at an outpatient hemodialysis unit—New York 2001-2008. MMWR Morb Mortal Wkly Rep. 2009;58(8):189–194. [PubMed] [Google Scholar]
  • 243.Collier M.G. Detection, reporting, and treatment of hepatitis C infections among hemodialysis patients. Infect Control Hosp Epidemiol. 2017;38(4):493–494. doi: 10.1017/ice.2016.317. [DOI] [PubMed] [Google Scholar]
  • 244.Rao A.K. Outbreak of hepatitis C virus infections at an outpatient hemodialysis facility: the importance of infection control competencies. Nephrol Nurs J. 2013;40(2):101–110. 164; quiz 111. [PubMed] [Google Scholar]
  • 245.Alter M.J. The epidemiology of acute and chronic hepatis C. Clinics in Liver Disease. 1997;1:559–568. doi: 10.1016/s1089-3261(05)70321-4. [DOI] [PubMed] [Google Scholar]
  • 246.Alter M.J. Prevention of spread of hepatitis C. Hepatology. 2002;26(5 suppl 1):S93–S98. doi: 10.1053/jhep.2002.36389. [DOI] [PubMed] [Google Scholar]
  • 247.Roth D. Grazoprevir plus elbasvir in treatment-naive and treatment-experienced patients with hepatitis C virus genotype 1 infection and stage 4-5 chronic kidney disease (the C-SURFER study): a combination phase 3 study. Lancet. 2015;386(10003):1537–1545. doi: 10.1016/S0140-6736(15)00349-9. [DOI] [PubMed] [Google Scholar]
  • 248.Fabrizi F., Martin P., Messa P. New treatment for hepatitis C in chronic kidney disease, dialysis, and transplant. Kidney Int. 2016;89(5):988–994. doi: 10.1016/j.kint.2016.01.011. [DOI] [PubMed] [Google Scholar]
  • 249.Kamili S. Laboratory diagnostics for hepatitis C virus infection. Clin Infect Dis. 2012;55(suppl 1):S43–S48. doi: 10.1093/cid/cis368. [DOI] [PubMed] [Google Scholar]
  • 250.Centers for Disease Control and Prevention Testing for HCV infection: an update of guidance for clinicians and laboratorians. MMWR Morb Mortal Wkly Rep. 2013;62(18):362–365. [PMC free article] [PubMed] [Google Scholar]
  • 251.Mbaeyi C., Thompson N.D. Hepatitis C virus screening and management of seroconversions in hemodialysis facilities. Semin Dial. 2013;26(4):439–446. doi: 10.1111/sdi.12097. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 252.Kidney Disease Improving Global Outcomes, KDIGO clinical practice guidelines for the prevention, diagnosis, evaluation, and treatment of hepatitis C in chronic kidney disease. Kidney Int Suppl. 2008;(109):S1–99. doi: 10.1038/ki.2008.81. [DOI] [PubMed] [Google Scholar]
  • 253.Centers for Disease Control and Prevention . In: Control Measures for hepatitis B in dialysis centers. Welfare H.E.a., editor. Department of Health, Education, and Welfare; Atlanta, GA: 1977. [Google Scholar]
  • 254.Alter M.J., Favero M.S., Francis D.P. Cost benefit of vaccination for hepatitis B in hemodialysis centers. J Infect Dis. 1983;148(4):770–771. doi: 10.1093/infdis/148.4.770a. [DOI] [PubMed] [Google Scholar]
  • 255.Alter M.J., Favero M.S., Maynard J.E. Impact of infection control strategies on the incidence of dialysis-associated hepatitis in the United States. J Infect Dis. 1986;153(6):1149–1151. doi: 10.1093/infdis/153.6.1149. [DOI] [PubMed] [Google Scholar]
  • 256.Centers for Disease Control and Prevention Recommendations of the Immunization Practices Advisory Committee (ACIP): Inactivated hepatitis B vaccine. MMWR Morb Mortal Wkly Rep. 1982;31(24):317–322. 327–328. [PubMed] [Google Scholar]
  • 257.Alter H.J. Type B hepatitis: the infectivity of blood positive for e antigen and DNA polymerase after accidental needlestick exposure. N Engl J Med. 1976;295(17):909–913. doi: 10.1056/NEJM197610212951701. [DOI] [PubMed] [Google Scholar]
  • 258.Shikata T. Hepatitis Be antigen and infectivity of hepatitis B virus. J Infect Dis. 1977;136(4):571–576. doi: 10.1093/infdis/136.4.571. [DOI] [PubMed] [Google Scholar]
  • 259.Bond W.W. Survival of hepatitis B virus after drying and storage for one week. Lancet. 1981;1(8219):550–551. doi: 10.1016/s0140-6736(81)92877-4. [DOI] [PubMed] [Google Scholar]
  • 260.Favero M.S. Detection methods for study of the stability of hepatitis B antigen on surfaces. J Infect Dis. 1974;129(2):210–212. doi: 10.1093/infdis/129.2.210. [DOI] [PubMed] [Google Scholar]
  • 261.Favero M.S. Letter: Hepatitis-B antigen on environmental surfaces. Lancet. 1973;2(7843):1455. doi: 10.1016/s0140-6736(73)92860-2. [DOI] [PubMed] [Google Scholar]
  • 262.Snydman D.R. Transmission of hepatitis B associated with hemodialysis: role of malfunction (blood leaks) in dialysis machines. J Infect Dis. 1976;134(6):562–570. doi: 10.1093/infdis/134.6.562. [DOI] [PubMed] [Google Scholar]
  • 263.Snydman D.R. Hemodialysis-associated hepatitis: report of an epidemic with further evidence on mechanisms of transmission. Am J Epidemiol. 1976;104(5):563–570. doi: 10.1093/oxfordjournals.aje.a112331. [DOI] [PubMed] [Google Scholar]
  • 264.Niu M.T. Hemodialysis-associated hepatitis B: report of an outbreak. Dial Transplant. 1989;18:542–555. [Google Scholar]
  • 265.Centers for Disease Control and Prevention Outbreaks of hepatitis B virus infection among hemodialysis patients—California, Nebraska, and Texas, 1994. MMWR Morb Mortal Wkly Rep. 1996;45(14):285–289. [PubMed] [Google Scholar]
  • 266.Alter M.J., Ahtone J., Maynard J.E. Hepatitis B virus transmission associated with a multiple-dose vial in a hemodialysis unit. Ann Intern Med. 1983;99(3):330–333. doi: 10.7326/0003-4819-99-3-330. [DOI] [PubMed] [Google Scholar]
  • 267.Carl M., Francis D.P., Maynard J.E. A common-source outbreak of hepatitis B in a hemodialysis unit. Dial Transplant. 1983;12:222–229. [Google Scholar]
  • 268.Hutin Y.J. An outbreak of hospital-acquired hepatitis B virus infection among patients receiving chronic hemodialysis. Infect Control Hosp Epidemiol. 1999;20(11):731–735. doi: 10.1086/501573. [DOI] [PubMed] [Google Scholar]
  • 269.Public Health Laboratory Service Survey Decrease in the incidence of hepatitis in dialysis units associated with prevention programme. Br Med J. 1974;4(5947):751–754. [PMC free article] [PubMed] [Google Scholar]
  • 270.Najem G.R. Control of hepatitis B infection. The role of surveillance and an isolation hemodialysis center. JAMA. 1981;245(2):153–157. doi: 10.1001/jama.245.2.153. [DOI] [PubMed] [Google Scholar]
  • 271.Rhea S. Hepatitis B reverse seroconversion and transmission in a hemodialysis center: a public health investigation and case report. Am J Kidney Dis. 2016;68(2):292–295. doi: 10.1053/j.ajkd.2016.03.424. [DOI] [PubMed] [Google Scholar]
  • 272.Rangel M.C. Vaccine recommendations for patients on chronic dialysis. The Advisory Committee on Immunization Practices and the American Academy of Pediatrics. Semin Dial. 2000;13(2):101–107. doi: 10.1046/j.1525-139x.2000.00029.x. [DOI] [PubMed] [Google Scholar]
  • 273.Mast E.E. A comprehensive immunization strategy to eliminate transmission of hepatitis B virus infection in the United States: recommendations of the Advisory Committee on Immunization Practices (ACIP) Part II: immunization of adults. MMWR Recomm Rep. 2006;55(RR-16):1–33. quiz CE1–4. [PubMed] [Google Scholar]
  • 274.Mast E.E. A comprehensive immunization strategy to eliminate transmission of hepatitis B virus infection in the United States: recommendations of the Advisory Committee on Immunization Practices (ACIP) part I: immunization of infants, children, and adolescents. MMWR Recomm Rep. 2005;54(RR-16):1–31. [PubMed] [Google Scholar]
  • 275.Hoofnagle J.H., Di Bisceglie A.M. Serologic diagnosis of a cute and chronic hepatitis. Sem Liver Dis. 1991;11(2):73–83. doi: 10.1055/s-2008-1040426. [DOI] [PubMed] [Google Scholar]
  • 276.Hochberger S. Fully automated quantitation of hepatitis B virus (HBV) DNA in human plasma by the COBAS AmpliPrep/COBAS TaqMan system. J Clin Virol. 2006;35(4):373–380. doi: 10.1016/j.jcv.2006.01.003. [DOI] [PubMed] [Google Scholar]
  • 277.Kaneko S. Hepatitis B virus DNA detection and comparison with hepatitis B surface antigen. Gastroenterol Jpn. 1990;25(suppl 2):57–61. doi: 10.1007/BF02779930. [DOI] [PubMed] [Google Scholar]
  • 278.Dienstag J.L. A preliminary trial of lamivudine for chronic hepatitis B infection. N Engl J Med. 1995;333(25):1657–1661. doi: 10.1056/NEJM199512213332501. [DOI] [PubMed] [Google Scholar]
  • 279.Bourne E.J. Quantitative analysis of HBV cccDNA from clinical specimens: correlation with clinical and virological response during antiviral therapy. J Viral Hepat. 2007;14(1):55–63. doi: 10.1111/j.1365-2893.2006.00775.x. [DOI] [PubMed] [Google Scholar]
  • 280.Dienstag J.L. Extended lamivudine retreatment for chronic hepatitis B: maintenance of viral suppression after discontinuation of therapy. Hepatology. 1999;30(4):1082–1087. doi: 10.1002/hep.510300427. [DOI] [PubMed] [Google Scholar]
  • 281.Dienstag J.L. Lamivudine as initial treatment for chronic hepatitis B in the United States. N Engl J Med. 1999;341(17):1256–1263. doi: 10.1056/NEJM199910213411702. [DOI] [PubMed] [Google Scholar]
  • 282.Lai C.L. A one-year trial of lamivudine for chronic hepatitis B. Asia Hepatitis Lamivudine Study Group. N Engl J Med. 1998;339(2):61–68. doi: 10.1056/NEJM199807093390201. [DOI] [PubMed] [Google Scholar]
  • 283.Hadler S.C. Epidemiological analysis of the significance of low-positive test results for antibody to hepatitis B surface and core antigens. J Clin Microbiol. 1984;19(4):521–525. doi: 10.1128/jcm.19.4.521-525.1984. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 284.Mezzelani P. [The significance of the isolated anti-HBc carrier. A study of 1797 drug addicts. The Intersert Group of Scientific Collaboration] Recenti Prog Med. 1994;85(9):419–424. [PubMed] [Google Scholar]
  • 285.Levine O.S. Seroepidemiology of hepatitis B virus in a population of injecting drug users. Association with drug injection patterns. Am J Epidemiol. 1995;142(3):331–341. doi: 10.1093/oxfordjournals.aje.a117639. [DOI] [PubMed] [Google Scholar]
  • 286.Satake M. Infectivity of blood components with low hepatitis B virus DNA levels identified in a lookback program. Transfusion. 2007;47(7):1197–1205. doi: 10.1111/j.1537-2995.2007.01276.x. [DOI] [PubMed] [Google Scholar]
  • 287.Bhatti F.A. Anti-hepatits B core antigen testing, viral markers, and occult hepatitis B virus infection in Pakistani blood donors: implications for transfusion practice. Transfusion. 2007;47(1):74–79. doi: 10.1111/j.1537-2995.2007.01066.x. [DOI] [PubMed] [Google Scholar]
  • 288.Silva A.E. Hepatitis B virus DNA in persons with isolated antibody to hepatitis B core antigen who subsequently received hepatitis B vaccine. Clin Infect Dis. 1998;26(4):895–897. doi: 10.1086/513918. [DOI] [PubMed] [Google Scholar]
  • 289.McMahon B.J. Response to hepatitis B vaccine of persons positive for antibody to hepatitis B core antigen. Gastroenterology. 1992;103(2):590–594. doi: 10.1016/0016-5085(92)90851-o. [DOI] [PubMed] [Google Scholar]
  • 290.Lai C.L. Significance of isolated anti-HBc seropositivity by ELISA: implications and the role of radioimmunoassay. J Med Virol. 1992;36(3):180–183. doi: 10.1002/jmv.1890360306. [DOI] [PubMed] [Google Scholar]
  • 291.Hadler, S.C. and H.A. Fields, eds. Hepatitis delta virus. Textbook of Human Virology, ed. B.B. Belshe. 1991, Mosby: St. Louis, MO. 749–765.
  • 292.Lettau L.A. Nosocomial transmission of delta hepatitis. Ann Intern Med. 1986;104(5):631–635. doi: 10.7326/0003-4819-104-5-631. [DOI] [PubMed] [Google Scholar]
  • 293.Velandia M. Transmission of HIV in dialysis centre. Lancet. 1995;345(8962):1417–1422. doi: 10.1016/s0140-6736(95)92603-8. [DOI] [PubMed] [Google Scholar]
  • 294.El Sayed N.M. Epidemic transmission of human immunodeficiency virus in renal dialysis centers in Egypt. J Infect Dis. 2000;181(1):91–97. doi: 10.1086/315167. [DOI] [PubMed] [Google Scholar]
  • 295.Arduino M.J. Preventing health-care associated transmission of bloodborne pathogens in hemodialysis facilities. Seminars in Infect Control. 2001;1(1):49–60. [Google Scholar]
  • 296.Favero M.S. Transmission of HIV in dialysis units. Anna J. 1993;20(5):599–600. [PubMed] [Google Scholar]
  • 297.Dyer E. Argentinian doctors accused of spreading AIDS. BMJ. 1993;307(6904):584. [PubMed] [Google Scholar]
  • 298.Mashragi F. HIV transmission at a Saudi Arabia hemodialysis unit. Clin Infect Dis. 2014;59(6):897–902. doi: 10.1093/cid/ciu373. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 299.Team W.H.O.E.R. Ebola virus disease in West Africa–the first 9 months of the epidemic and forward projections. N Engl J Med. 2014;371(16):1481–1495. doi: 10.1056/NEJMoa1411100. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 300.Vallabhaneni S. Investigation of the first seven reported cases of candida auris, a globally emerging invasive, multidrug-resistant fungus—United States, May 2013-August 2016. MMWR Morb Mortal Wkly Rep. 2016;65(44):1234–1237. doi: 10.15585/mmwr.mm6544e1. [DOI] [PubMed] [Google Scholar]
  • 301.Hess S., Bren V. Essential components of an infection prevention program for outpatient hemodialysis centers. Semin Dial. 2013;26(4):384–398. doi: 10.1111/sdi.12102. [DOI] [PubMed] [Google Scholar]
  • 302.Centers for Disease Control and Prevention . Pyrogenic reactions and gram-negative bacteremia in a hemodialysis center, in Epidemic Investigation Report. In: C.f.D.C.a.P. (Centers for Disease Control and Prevention), editor. Author; Atlanta, GA: 1991. [Google Scholar]
  • 303.Centers for Disease Control and Prevention . Epidemiologic Investigations Report, CDC. Centers for Disease Control and Prevention; Atlanta, GA: 1992. Bacteremia in hemodialysis patients. [Google Scholar]
  • 304.Clark T. Outbreak of bloodstream infection with the mold Phialemonium among patients receiving dialysis at a hemodialysis unit. Infect Control Hosp Epidemiol. 2006;27(11):1164–1170. doi: 10.1086/508822. [DOI] [PubMed] [Google Scholar]
  • 305.Centers for Disease Control and Prevention Bacteremia associated with reuse of disposable hollow-fiber hemodialyzers. MMWR Morb Mortal Wkly Rep. 1986;35:417–418. [PubMed] [Google Scholar]
  • 306.Murphy J. Outbreaks of bacteremia in hemodialysis patients associated with alteration of dialyzer membranes [abstract] Asaio J. 1987;16:51. [Google Scholar]
  • 307.Centers for Disease Control and Prevention . Pyrogenic reactions in patients undergoing high-flux hemodialysis–California, in Epidemic Investigations Report. In: C.f.D.C.a.P. (Centers for Disease Control and Prevention), editor. Author; Atlanta, GA: 1987. [Google Scholar]
  • 308.Centers for Disease Control and Prevention . Pyrogenic reactions in hemodialysis patients on high-flux hemodialsis–California, in Epidemic Investigations Report. In: C.f.D.C.a.P. (Centers for Disease Control and Prevention), editor. Author; Atlanta, GA: 1987. [Google Scholar]
  • 309.Kantor R.J. Outbreak of hepatitis B in a dialysis unit, complicated by false positive HBsg test results. Dial Transplant. 1979;8:232–235. [Google Scholar]
  • 310.Centers for Disease Control and Prevention . CDC; Atlanta, GA: 1993. Outbreak of hepatitis B in a dialysis center. Epidemic Investigation Report EPI91-17. Atlanta, CDC, 1993, in Epidemic Investigations Report. [Google Scholar]
  • 311.Centers for Disease Control and Prevention . Non-A, Non-B hepatitis in a dialysis center, Nashville, Tennessee., in Epidemic Investigation Report. In: C.f.D.C.a.P. (Centers for Disease Control and Prevention), editor. Author; Atlanta, GA: 1979. [Google Scholar]
  • 312.Niu M.T. Outbreak of hemodialysis-associated non-A, non-B hepatitis and correlation with antibody to hepatitis C virus. Am J Kidney Dis. 1992;19(4):345–352. doi: 10.1016/s0272-6386(12)80452-5. [DOI] [PubMed] [Google Scholar]
  • 313.Lake J. 2016. Improving Infection Control in Hemodialysis Centers After Acute Hepatitis C Infections, in National Kidney Foundation Spring Clinical Meeting. Boston, MA. [Google Scholar]

Articles from Chronic Kidney Disease, Dialysis, and Transplantation are provided here courtesy of Elsevier

RESOURCES