Summary
Loop‐mediated isothermal amplification (LAMP) amplifies DNA with high specificity, efficiency and rapidity under isothermal conditions by using a DNA polymerase with high displacement strand activity and a set of specifically designed primers to amplify targeted DNA strands. Following its first discovery by Notomi et al. (2000 Nucleic Acids Res 28: E63), LAMP was further developed over the years which involved the combination of this technique with other molecular approaches, such as reverse transcription and multiplex amplification for the detection of infectious diseases caused by micro‐organisms in humans, livestock and plants. In this review, available types of LAMP techniques will be discussed together with their applications in detection of various micro‐organisms. Up to date, there are varieties of LAMP detection methods available including colorimetric and fluorescent detection, real‐time monitoring using turbidity metre and detection using lateral flow device which will also be highlighted in this review. Apart from that, commercialization of LAMP technique had also been reported such as lyophilized form of LAMP reagents kit and LAMP primer sets for detection of pathogenic micro‐organisms. On top of that, advantages and limitations of this molecular detection method are also described together with its future potential as a diagnostic method for infectious disease.
Keywords: biotechnology, detection, diagnosis, diseases, rapid methods
Introduction
Nucleic acid amplification is one of the most valued methods across all fields of science, from diagnosis of infectious diseases to application in biotechnology (Parida et al. 2008). In addition to the widely used polymerase chain reaction (PCR)‐based detection, numerous amplification techniques were designed (Guatelli et al. 1990). Examples of popular methods used are nucleic acid sequence‐based amplification (Malek et al. 1994), self‐sustained sequence replication (3SR; Fahy et al. 1991) and strand displacement amplification (SDA; Walker et al. 1992). Each of these methods has a different set of requirements to initiate DNA synthesis. For instance, PCR involves heat to denature the double‐stranded target DNA into single‐stranded to initiate DNA synthesis. SDA uses strand displacement action of exo‐klenow to produce target DNA copies from 5′ to 3′ and the procedure occurs at a single temperature (Walker et al. 1992). These methods are widely used in all fields of science to amplify the target sequence. However, they still suffer from insufficiencies and inadequacies. All these methods require a sophisticated instrument for amplification and detection or elaborate methods for performance (Fang et al. 2008). As a result, researchers and scientists have worked hard to overcome these limitations.
In the past decade, numerous isothermal amplification techniques were established. These include recombinase polymerase amplification, rolling circle amplification and helicase‐dependent amplification (Zanoli and Spoto 2013). Finally, Notomi et al. (2000) successfully devised a novel isothermal amplification method to amplify a limited amount of DNA copies into a million copies within an hour. This method is known as loop‐mediated isothermal amplification (LAMP).
LAMP is a novel molecular technique of nucleic acid amplification where a set of four (or six) different primers binds to six (or eight) different regions on the target gene making it highly specific (Notomi et al. 2000). This primer set consists of two outer (F3 and B3) primers, two inner primers (forward inner primer (FIP) and backward inner primer (BIP)) and loop primers (loop forward and loop backward). LAMP reaction can be done simply at an isothermal condition (Chen et al. 2015) by using Bst DNA polymerase which have high‐displacement activity (Notomi et al. 2000). An illustration on the LAMP primers binding sites and the amplification process is given in Fig. 1.
Figure 1.

Schematic representation of LAMP reaction and its principle. LAMP reaction involved reaction mixture consists of dNTPs mix, Bst polymerase, fluorescence dye, primers and DNA template. Primer design: Design of primer for LAMP reaction and is characterized by the use of four different primers specially designed to recognize six distinct regions of the target DNA. Forward Inner Primer (FIP) consists of a F2 region at the 3'‐end and an F1c region at the 5'‐end; Forward Outer Primer (F3 Primer) consists of a F3 region which is complementary to the F3c region of the template sequence; Backward Inner Primer (BIP) consists of a B2 region at the 3'‐end and a B1c region at the 5'‐end. Backward Outer Primer (B3 Primer) consists of a B3 region which is complementary to the B3c region of the template sequence. LAMP reaction: The amplification starts when F2 region of FIP hybridizes to F2c region of the target DNA and initiates complementary strand synthesis, follow by F3 primer that hybridizes to the F3c region of the target DNA and extends, displacing the FIP linked complementary strand. This displaced strand forms a loop at the 5'‐end. This single‐stranded DNA with a loop at the 5'‐end then serves as a template for BIP. B2 hybridizes to B2c region of the template DNA. DNA synthesis is initiated leading to the formation of a complementary strand and opening of the 5'‐end loop. Subsequently, B3 hybridizes to B3c region of the target DNA and extends, displacing the BIP linked complementary strand. This results in the formation of a dumbbell‐shaped DNA. The nucleotides are added to the 3'‐end of F1 by Bst DNA polymerase, which extends and opens up the loop at the 5'‐end. The dumbbell‐shaped DNA now gets converted to a stem‐loop structure (refer a and b). This structure serves as an initiator for LAMP cycling, which is the second stage of the LAMP reaction. Loop primers can be added as well for exponential amplification of LAMP. The final products obtained are a mixture of stem‐loop DNA with various stem lengths and various cauliflower‐like structures with multiple loops. Fig. 1 was modified from Notomi et al. (2000). [Colour figure can be viewed at http://wileyonlinelibrary.com]
Different forms of LAMP assays
Since its development in Notomi et al. (2000), LAMP has undergone numerous advancement in terms of its applications as a molecular amplification technique. In this section, different forms of LAMP assays including conventional LAMP, reverse‐transcription LAMP, multiplex LAMP and a few other LAMP forms for detection of micro‐organisms will be discussed in details.
Conventional LAMP
LAMP was successfully demonstrated to detect human respiratory pathogens, such as Mycobacterium tuberculosis (Kumar et al. 2014; Bentaleb et al. 2016; Nagai et al. 2016; Sethi et al. 2016; Sharma et al. 2016; Kaewphinit et al. 2017), Streptococcus pneumoniae (Seki et al. 2005; Xia et al. 2014), Bordetella pertussis (Fujino et al. 2015; Brotons et al. 2016; Kamachi et al. 2017), and carbapenem‐resistant Klebsiella pneumoniae (Nakano et al. 2015). Furthermore, LAMP was also devised to diagnose pathogens associated with food‐borne diseases, for instance, Salmonella typhi (Abdullah et al. 2014; Fan et al. 2015), Campylobacter jejuni and Campylobacter coli (Pham et al. 2015), and Helicobacter pylori (Bakhtiari et al. 2016; Yari et al. 2016). Other successful examples of LAMP usage include Neisseria meningitidis (Lee et al. 2015), Listeria monocytogenes (Birmpa et al. 2015; Wang et al. 2015b; Ye et al. 2015), Entamoeba histolytica (Rivera and Ong 2013; Singh et al. 2013; Mwendwa et al. 2017), and human leptospirosis (Seesom et al. 2015; Hsu et al. 2017). LAMP was also efficiently formulated against several multidrug‐resistant Pseudomonas aeruginosa and Acinetobacter baumannii (Kim et al. 2016b). The high LAMP assay usage proves its potential as a means for accurate molecular detection and to differentiate human pathogens.
Recently, LAMP was used for the detection of a wide range of viruses. For example, adenovirus (Ziros et al. 2015), varicella zoster (Kobayashi et al. 2014; Niihara et al. 2017) and cytomegalovirus (Wang et al. 2015a). Hepatoviruses such as hepatitis B (Zhao et al. 2016) can also be detected using LAMP technique. The results showed that LAMP assay is promising for hepatitis diagnostics, donor screening, epidemiological studies and therapeutic monitoring of patients undergoing antiviral treatment.
Protozoan parasites are equally harmful to humans and are one of the leading causes of death in the world. A parasitic disease detected by using LAMP was for malaria diagnosis of Plasmodium spp. (Britton et al. 2016; Lau et al. 2016; Zhang et al. 2017). Poole et al. (2015) developed a highly sensitive LAMP for Loa loa detection, targeting the RF4 genes. The study reported that RF4‐specific LAMP can detect 1 microfilaria which is equivalent to 100 pg within 30 min. These studies provide examples of how LAMP can be implemented in field detection and early management of the parasitic infection (Poole et al. 2015).
A research was conducted by Nzelu et al. (2014) to detect Leishmania. In the study, they developed LAMP and tested it with 122 suspected clinical samples. The study showed that LAMP was efficient to detect 101 copies of DNA. They concluded that the newly developed LAMP was helpful when leishmania parasite density is very low, especially during the early infection stage (Nzelu et al. 2014, 2016). There was a number of other reported significant practices of LAMP including Trichomonas viganalis (Reyes et al. 2014), Necator americanus (Mugambi et al. 2015) and Strongyloides stercoralis (Watts et al. 2014), and it was shown that LAMP is at least 1000 times more sensitive than the conventional PCR.
The routine detection of fungi is laborious and expensive. A recent study was carried out to detect an extensive range of fungi, including Candida albicans, Cryptococcus neoformans and Mucor racemosus. The study reported the sensitivity of LAMP assay was 102 copies per 25 μl reaction. The assay can be efficiently used to detect fungi from the environment (Nakayama et al. 2017). Another study was carried out by Luo et al. (2014) to detect aflatoxins by Aspergillus flavus, Aspergillus parasiticus and Aspergillus nomius. The study developed real‐time LAMP to quantify A. flavus, A. parasiticus and A. nomius, and stated the detection limits of 101, 102 and 103, respectively, at 65°C within 60 min. The real‐time LAMP assay established could be a promising assay for early diagnosis of Aspergillus infection in humans (Luo et al. 2014).
Other successful examples of LAMP usage to detect fungal infections include Fonsecaea species (Sun et al. 2010), Trichosporon asahii and Pneumocystis jirovecii (Nakashima et al. 2014; Singh et al. 2015). LAMP requires minute quantities of DNA for detection of the fungal pathogen with unrivalled high sensitivity and easy handling. These qualities make LAMP suitable for all ranges of applications in the diagnosis of communicable diseases.
Reverse transcription LAMP
Reverse transcription loop‐mediated isothermal amplification (RT‐LAMP) is a one‐step nucleic acid amplification technique used by taking a step further and adding LAMP with a reverse transcriptase enzyme to allow RNA detection (Notomi et al. 2000). Like RT‐PCR, RT‐LAMP uses reverse transcriptase to make complementary DNA from RNA and is further amplified by using DNA polymerase. This method is valuable and beneficial because the assay can be completed in a single step, by incubating all the primers and enzymes (Bst polymerase and reverse transcriptase) with a constant temperature (Notomi et al. 2000, 2015; Mori et al. 2013), and this was very effective in detecting viruses with an RNA genome.
RT‐LAMP was established for Dengue virus (Hu et al. 2015; Lau et al. 2015), influenza viruses (Nakauchi et al. 2014; Bao et al. 2015; Kim et al. 2016a), Hepatitis C (Nyan and Swinson 2016; Zhao et al. 2017), Ebola virus (Oloniniyi et al. 2017), respiratory syncytial virus (Hoos et al. 2017), zika virus (Tian et al. 2016; Wang et al. 2016; Chotiwan et al. 2017) and Middle East Respiratory Syndrome coronavirus (Mers‐CoV) (Li et al. 2015; Lee et al. 2016). Apart from helping in diagnosis, the RT‐LAMP can also be used as an epidemiologic surveillance system for human virus infections.
Currently, one of the most successful uses of RT‐LAMP is diagnosing the HIV retrovirus. RT‐LAMP was developed to diagnose dormant HIV stage in infected individuals (Ocwieja et al. 2015; Odari et al. 2015). A recent advancement was carried out by Damhorst et al. (2015) by incorporating a digital device with RT‐LAMP to provide a smartphone‐image of positive HIV‐1 detection from whole blood. The assay showed sensitivity of 670 viruses per microlitre of whole blood. The digital RT‐LAMP method could be used for the detection of viral load from a simple finger prick of blood from HIV‐positive individuals in primary care amenities and clinical laboratory. The assay is functional for hospital‐based infection control and for laboratory‐based observations (Damhorst et al. 2015).
A recent study by Tian et al. (2016) also used RT‐LAMP for the detection of synthetic zika virus (ZIKV) by targeting the NS5 gene. Although the study was only tested with synthetic ZIKV, it was one of a few studies that used a dual enzyme activity, Bst 3.0 polymerase which could amplify both DNA and RNA under the same conditions. The sensitivity of the assay was reported to be 1 attomolar (aM) synthetic ZIKV within 30 min. The study also reported no cross‐reactivity with closely related Flaviviruses (Tian et al. 2016).
RT‐LAMP was also used to detect plant pathogens. One of the recent examples of RT‐LAMP plant pathogens detection is Apple chlorotic leaf spot virus (ACLSV), by targeting the virus coat protein gene. The reaction conditions were optimized according to temperature and reaction time. The RT‐LAMP developed was capable to detect concentration as low as 0·02 μg μl−1 at 64°C. The study reported that RT‐LAMP has a 100‐fold greater sensitivity as compared with RT‐PCR (2·29 μg μl−1). The assay could be successfully applied to field‐collected apples to diagnose the diseases and to potentially control the spreading of ACLSV (Peng et al. 2017).
RT‐LAMP was as well developed for animal pathogens, for example, Batai virus (BATV), a mosquito‐borne virus, which would cause congenital defects in ruminants (cattle). Liu et al. (2016) developed and optimized RT‐LAMP targeting the M gene of BATV. The time detection of BATV was reduced to 40 min, at 65°C, when RT‐PCR would normally take hours. The results were simply and readily visualized with the naked eye on colour change. The assay reported a sensitivity of 2·86 copies per μl, which is roughly 100 folds higher than qRT‐PCR. Therefore, RT‐LAMP showed a promising diagnostic tool for BATV detection, especially in the farm house (Liu et al. 2016).
A novel RT‐LAMP was developed by Chander et al. (2014) and it was the first study to report the application of novel polymerase, OmniAmp polymerase. The polymerase enzyme exhibited similar activity to that of Bst 3.0 polymerase that allows the direct detection of both DNA and RNA. RT‐LAMP assays were developed for six RNA viruses. All targets were amplified within 30 min without extra steps or alteration of the reaction designs used for DNA targets. In comparison to the conventional Bst polymerase, OmniAmp polymerase was reported to be less inhibited by whole blood components, more rapid detection for diluted low viremia samples, more thermostable and perfect with a dry set‐up that allows extended storage period at ambient temperature, thus it was more suitable for the development of lateral flow device and lyophilized LAMP. Considering the qualities, OmniAmp polymerase is more suitable to be used for molecular diagnostic in field setting (Chander et al. 2014).
Multiplex LAMP
Simultaneous detection of multiple target genes could enhance the specificity and reliability of a diagnosis method. This was applied in LAMP reaction as an advancement of the method, namely multiplex LAMP (mLAMP). Lau et al. (2015) developed RT‐LAMP in a single tube coupled with mLAMP approach for detection of the dengue virus. This is one of the simplest mLAMP approach reported since identification of specific LAMP product was not needed. In this study, LAMP primer sets were specifically designed for each serotype of the dengue virus: DENV‐1, DENV‐2, DENV‐3 and DENV‐4 targeting on the 3′‐noncoding region (NCR). Interestingly, all the primer sets were added together into a single tube of LAMP reaction to detect the presence of the dengue virus within 60 min of a LAMP reaction. The samples used in this reaction was the serum of dengue infected patients and healthy donors. Colorimetric detection was performed by using hydroxynaphthol blue (HNB), in which it allows the naked eye observation of final LAMP products. The sensitivity of this RT‐mLAMP system was 10 RNA copies for all serotypes, and there was no cross‐reactivity with three closely related arboviruses observed (Lau et al. 2015).
Due to formation of multiple amplicons in the mLAMP products, this method needs to be coupled with several types of multiplex product detection method to specifically differentiate them. One of the example is combining mLAMP with dot enzyme‐linked immunosorbent assay (dot‐ELISA) for differential identification of Taenia solium, Taenia saginata and Taenia asiatica, where cytochrome c oxidase subunit 1 gene was chosen as the target (Nkouawa et al. 2016). In this study, a single tube of mLAMP reaction was performed with FIP primers labelled with fluorescein isothiocyanate (FITC), digoxigenin (DIG) and tetramethylrhodamine (TAMRA), and BIP primers labelled with biotin. The mLAMP products from each plasmid containing the cox1 genes for T. solium, T. saginata and T. asiatica were captured by antibodies that were specific for FITC, DIG and TAMRA, respectively. Following this, Strep‐Tactin alkaline phosphatase conjugate and chromogenic substrate was used to detect the mLAMP products. A positive result was indicated by purple dots developed on the membrane while uncoloured dots represented a negative result permitting the differential detection of these species.
A study by Lee et al. (2010) reported the development of a one‐tube reaction by using LAMP‐PCR, hybridization, digestion with restriction endonuclease and colorimetric method of ELISA for the detection of M. tuberculosis that resistance to isoniazid, ethambutol and streptomycin. This was made possible by targeting hot spot point mutations in targeted drug‐resistant genes: for isoniazid at katG 315 and katG 463, ethambutol at embB 306 and embB 497, and streptomycin at rpsL 43. In a reaction tube, LAMP primer sets targeting each of the mentioned point mutations and specific internal primers for PCR of individual resistance genes were added together with mycobacterial DNA template. The mixture was incubated at 65°C for 30 min to perform LAMP reaction followed by PCR assay by using LAMP products as the template. For differentiation of wild‐type codons of resistance genes from mutant codon, specific restriction endonucleases were added to LAMP‐PCR products where wild‐type products were digested by specific restriction endonucleases. The digested products were then subjected to ELISA procedure where colour development and OD readings were recorded to indicate positive amplification for each target (Lee et al. 2010).
A rapid LAMP and real‐time monitoring procedure was combined for the simultaneous detection of food‐borne disease pathogens, such as Salmonella spp. and Vibrio parahaemolyticus, as reported by Liu et al. (2017). In a reaction tube, primer sets targeting these two species, respectively, were added and subjected to LAMP reaction for 60 min. However, LAMP selection caused by amplification bias was observed where Salmonella target sequence amplification rate is higher over that of V. parahaemolyticus. In order to overcome this issue, concentration of primer set detecting Salmonella was halved which resulted in equal amplification efficiency of both target sequence. After the isothermal amplification reaction, the products were subjected to a melting curve analysis and difference in melting temperatures (T m values) during the LAMP reaction was observed to distinguish these two pathogens (Liu et al. 2017).
A novel mLAMP was developed by Stratakos et al. (2017) for detection and differentiation of nonpathogenic Escherichia coli and verocytotoxigenic E. coli (VTEC) in beef and bovine faeces. The mLAMP assay was designed for the detection of generic E. coli (nonpathogenic) targeting the phoA gene and VTEC strains targeting the stx1 or stx2 genes at 65°C for 30 min. In terms of the assay specificity, no cross‐reactions were reported when 58 bacterial strains and specimens was used. Limit of detection for this assay was reported to be 103–102 CFU per g, which may be adequate to be used for monitoring hygienic status of beef and to control food‐borne diseases caused by VTEC (Stratakos et al. 2017).
The utility of mLAMP for detection of multiple genes for specific identification of parasites in mosquitoes was reported by Aonuma et al. (2010). In this reaction, a mixture of LAMP primers for the detection of SPECT2 gene of Plasmodium berghei and cytochrome oxidase subunit I gene of Dirofilaria immitis was used. The FIP for each primer set was specifically labelled with FITC for P. berghei and cyanine5.5 (Cy5.5) for D. immitis. Real‐time turbidity metre was used to monitor the amplification reaction and image analyser was used to examine the fluorescent dye‐conjugated fragments. Green fluorescence signal produced by FITC indicated positive amplification of P. berghei, while for D. immitis, a magenta colour of Cy.55 was observed. This permitted the simultaneous detection of these two‐parasitic species (Aonuma et al. 2010).
Electric LAMP
A study reported by Salinas and Little (2012) explains on the development of electric LAMP (eLAMP), an electronic simulation where it provides a fast and inexpensive putative tests of LAMP primers on target sequences compatibility. This method helps to improve the efficiency and aids to determine the opportunity of using existing primers to detect recently discovered sequence variants (Salinas and Little 2012). In this study, sets of existing LAMP primers were tested using this eLAMP on 40 whole‐genome sequences of Staphylococcus. The results correctly predicted that the tested primer sets would amplify from Staphylococcus aureus genomes and not from other Staphylococcus species.
In‐disc LAMP
Santiago‐Felipe et al. (2016) developed an assay for detection of pathogenic Salmonella spp. and identification of bovine meat in meat samples by using the principle of in‐disc LAMP (iD‐LAMP) and quantitative optical read‐out by a disc drive. iD‐LAMP is an integrated device composed of micro‐reactors embedded onto compact discs for real‐time targeted DNA determination (Santiago‐Felipe et al. 2016). Similar reagents used in conventional LAMP were used in this iD‐LAMP except that it was performed in a micro‐reactor placed in a 65°C oven. During the incubation, the disc was cyclically scanned and a sample was considered positive when the optical response was greater than the cut‐off value. From this study, it shows that the result of iD‐LAMP was comparable to those obtained by conventional LAMP with an extra advantage of using a smaller amount of template.
LAMP end‐point detection method
Frequently used detection methods include turbidity, agarose gel electrophoresis, calorimetric detection using naked eyes and detection using UV light. Real‐time monitoring based on turbidity using real‐time turbidity metre (e.g. Loopamp Realtime Turbidimeter LA‐200, LA‐320, LA‐500, Eiken Chemical Co., Ltd., Tokyo, Japan) is commonly used for LAMP product detection. LAMP assay was monitored for the white precipitation caused by the presence of magnesium pyrophosphate, Mg2P2O7 (a by‐product of LAMP reaction) at optical density 650 nm every 6 s. Several studies have been reported using turbidity to detect the presence of desired micro‐organisms, for instances, Mycoplasma pneumoniae (Sakai et al. 2017), Salmonella spp. (Mashooq et al. 2016), human papillomavirus (Kumvongpin et al. 2016) and Clostridium difficile (Lin et al. 2015). In case of unavailability of turbidimeter, a brief centrifugation of the LAMP products could be used as an alternative to observe the white precipitation, which is visible to naked eyes (Zhou et al. 2014).
Agarose gel electrophoresis could be used to visualize LAMP products as well. The end products of LAMP gene amplification will be stem‐loop DNA structures with several inverted repeats of the target and cauliflower‐like structures with multiple loops which cause the gel electrophoresis image of these products to be in ladder‐like patterns. This method has been used for detection of E. histolytica (Mwendwa et al. 2017), S. aureus (Chen et al. 2017b), V. parahaemolyticus (Siddique et al. 2017), Clostridium perfringens (Radhika et al. 2016), parasitic tapeworm Echinococcus spp. (Ahmed et al. 2016), and plant disease caused by Southern tomato virus (Elvira‐Gonzalez et al. 2017). However, visualization of LAMP DNA product by gel electrophoresis required the opening of the reaction tubes, therefore increases the risk of carryover contamination, and application of gel electrophoresis is restricted due to the use of ethidium bromide stain, a highly hazardous chemical which is carcinogenic to human (Zhou et al. 2014).
An alternative to gel electrophoresis, intercalating dyes were used for direct detection of the DNA products, for example, calcein, SYBR green I and HNB dye. Calcein dye, a metal ion binding fluorophore, which was added before isothermal incubation will form an insoluble salt complex, manganese‐pyrophosphate (manganese ion, Mn2+ from calcein whereas pyrophosphate is the by‐product of LAMP reaction), thus making the reaction fluorescent. Subsequently, the fluorescence is further intensified when free calcein binds to magnesium ions (Mg2+ from LAMP reaction mixture) and could be easily be observed under UV light (365 nm; Sahoo et al. 2016). The reaction between Mg2+ and calcein also causes the colour changes from orange to green, which could be observed via naked eyes under natural light. Positive LAMP reaction was indicated with green colour, whereas negative LAMP reaction indicated with orange colour. To name a few, calcein has been used in detection of Trypanosoma cruzi (Besuschio et al. 2017), avian influenza H5 virus (Liu et al. 2013), hepatitis C virus (Zhao et al. 2017), human papillomavirus (Lin et al. 2017), human coronavirus (Geng et al. 2016) and Flavobacterium columnare in tilapia fish (Suebsing et al. 2015). Calcein‐based end‐point detection is most commonly used due to its high sensitivity and notable colour change for naked eye observation (Fischbach et al. 2015).
SYBR green I is also commonly used in LAMP assay. Addition of SYBR green I to reaction tubes containing LAMP products lead to visible colour change from reddish orange to yellowish green, and fluorescent under UV light. SYBR green I has been used for detection of coxsackievirus (Monazah et al. 2017), Plasmodium vivax and Plasmodium falciparum (Singh et al. 2017), Mycoplasma synoviae (Kursa et al. 2015), fish pathogen Nocardia salmonicida (Xia et al. 2015), maize chlorotic mottle virus (Chen et al. 2017a) and tomato chlorosis virus (Zhao et al. 2015). Despite reported with good sensitivity, SYBR green I dye could inhibit LAMP reaction if the dye is added before isothermal incubation. Post‐LAMP added dye required the opening of the LAMP tube which will leads to false‐positive results due to aerosol contamination (Karthik et al. 2014). HNB dye was commonly used as well for visualization of LAMP products. HNB dye changes from violet to sky blue colour and has been used for identification of Gram‐negative bacilli (Srisrattakarn et al. 2017), Chlamydia trachomatis (Choopara et al. 2016), and M. tuberculosis (Balne et al. 2015), orf virus in goat and cattle (Inoshima et al. 2017) and feline coronavirus (Stranieri et al. 2017). Addition of HNB dye in LAMP reaction tube prior amplification could help to reduce aerosol contamination to the surrounding; however, HNB does not exhibit fluorescent ability, thus, only limited to naked colour changes observation (summarized end‐point detection in Fig. 2).
Figure 2.

A summary of the commonly used LAMP detection method. (a) LAMP endpoint detection with turbidity, (b) LAMP calorimetric detection using calcein dye, (c) LAMP calorimetric detection using SYBR Green I dye, (d) LAMP calorimteric detection using HNB dye, and (e) analysis of LAMP product using gel electrophoresis. [Colour figure can be viewed at http://wileyonlinelibrary.com]
Other dyes such as malachite green dye (Sriworarat et al. 2015; Lucchi et al. 2016; Nzelu et al. 2016), Picogreen dye (Batra et al. 2015), Gelred dye (Wozniakowski et al. 2013; Wassermann et al. 2014), SYTO fluorescent dye (Liu et al. 2013; Watts et al. 2014; Mwendwa et al. 2017), Evagreen dye (Lee et al. 2016; Oscorbin et al. 2016), and Goldview II dye (Shi et al. 2011; Wu et al. 2014) were used as well for detection of LAMP DNA products. An alternative natural plant alkaloid dye known as berberine has been explored and used for detection of LAMP products. A study has been reported that berberine dye exhibit similar specificity and sensitivity compared with existing DNA intercalating dye and can be used as a fluorescent probe. Berberine dye is recommended for large field applications as it is cheaply available than other dyes (Fischbach et al. 2015).
Recently, more studies have been focused on developing lateral flow assay (LFA) for end‐point detection of LAMP product. LFA is currently a favoured technique due to low‐cost, user‐friendly, simple, rapid, light and portable. The sample of interest, for example, saliva, blood, urine and other body fluids, is applied at one end of the strip (sample pad), which is conjugated with LAMP buffer mix and biotin, making the loaded sample suitable for interaction with the detection system. Most generally, lateral flow test was established using fluorescein in isothiocyanate (FITC) labelled DNA probes (which will recognize the specific region in the LAMP amplicon) hybridized with biotinylated LAMP amplicons (Thongkao et al. 2015; Fowler et al. 2016; Huang et al. 2017; Park et al. 2017). This complex would be captured by streptavidin on the biotin, forming another complex with anti‐FITC antibody coated on the gold nanoparticles. This would give a visible result on the test line. However, the biotinylated nontargeted product would not hybridize with FITC DNA probe (only specific to LAMP amplicon), nor forming complexes with gold‐labelled anti‐FITC antibody to react with streptavidin on the test line, generating no signal thus a negative result on the test line. This complex would then move through the test line and was trapped at the control line (Chowdry et al. 2014; Yan et al. 2015; Nawattanapaiboon et al. 2016).
Successful LFA includes multiplex LFA‐LAMP to simultaneously detect sea and seb gene of S. aureus (Yin et al. 2016) and identification of adulterants in meats (Li and Fan 2016). Lateral flow dipstick (LFD) was developed as well for simultaneous detection of pathogenic Leptospira spp. (Nurul Najian et al. 2016), measles virus (Xu et al. 2016), animal babesiosis, caused by Babesia bovis and Babesia bigemina (Yang et al. 2016), foot‐and‐mouth diseases (Waters et al. 2014), Japanese encephalitis (Deng et al. 2015), P. vivax, and P. falciparum (Yongkiettrakul et al. 2014; Kongkasuriyachai et al. 2017), Jembrana disease virus (Kusumawati et al. 2015), canine parvovirus (Sun et al. 2014), Vibrio alginolyticus (Plaon et al. 2015), Macrobrachium rosenbergii nodavirus (Lin et al. 2014) and shrimp yellow head virus (Khunthong et al. 2013). Lateral flow biosensor (LFB) was successfully developed for multiplex detection of Enterococcus faecalis and S. aureus. The development of the LFB with gold nanoparticles had greatly helped in the visual detection of human pathogens without any instrumentation (Wang et al. 2017).
Further advancement of LAMP end‐point detection was made when Draz and Lu (2016) developed LAMP coupled with Surface Enhanced Raman spectroscopy (SERS) for rapid detection of Salmonella enteritidis. The study reported SERS detection labelling with Raman active gold nanoparticle was highly sensitive (100 times more than PCR), requires little sample preparation, and improves specificity and reliability by limiting false‐positive results (Draz and Lu, 2016).
Advances in LAMP
Moving towards the application of LAMP as a point‐of‐care detection method, several advances have been reported to date including development of lyophilized form of LAMP reagents and commercially available LAMP kit for micro‐organisms' specific detection.
Lyophilized LAMP is a term used for the dried form of LAMP reagents, where it can withstand ambient temperature and long storage before being used for any molecular detection purpose hence the making of on‐site diagnosis is possible. One of the examples on the utilization of lyophilized LAMP was reported by Hayashida et al., where they developed a single tube of dried LAMP reagent for diagnosis of human African trypanosomiasis on‐site. By using this lyophilized LAMP reagents, the detection limit for detection of repetitive insertion mobile element (RIME), 18S rRNA and SRA‐LAMP were 0·01, 0·1 and 1 parasite equivalent DNA per reaction, respectively. In terms of thermostability assessment, the lyophilized LAMP was incubated at 25 or 45°C for 72 h and used in comparison with fresh LAMP reagents for RIME‐LAMP reaction, where the result was comparable (Hayashida et al. 2015).
The application of lyophilized LAMP reagents was reported by Chen et al. (2016) for the detection of Leptospira by using a LAMP primers combination targeting lipL32 and lipL41 genes. Bst DNA polymerase, dNTPs and primers were supplemented with sugars and subjected to lyophilization in a freeze‐dryer. To evaluate the reagent stability and sensitivity, lyophilized LAMP reagents, which were stored at 4, 25 and 37°C, were used to test the detection limit alongside the freshly prepared LAMP reagents for Leptospira detection. The limit of detection observed for these two preparations were 12 copies of genomic DNA. In terms of stability, the results showed that lyophilized LAMP reagents retain the same reactivity as freshly prepared reagents and remain stable for up to 3 months when stored at 4°C (Chen et al. 2016).
One of the latest development of the lyophilization method of RT‐LAMP reaction was reported by Carter et al. (2017) with its application in the detection of Zaire Ebola Virus (ZEBOV). LAMP primers targeting L gene of ZEBOV were designed based on the alignment of isolates from 1976, 1995, 2007 and 2014 outbreaks as well as corresponding fragments were synthesized and cloned into plasmid which served as the template for in vitro transcription of the sense strand. The master mix was then subjected to cool in liquid nitrogen followed by freeze‐drying. In this study, they highlighted key modifications of the reaction components in order to maintain the lyophilized reagents stability, which was the addition of a nonreducing sugar trehalose and dialysis of the used enzyme preparations (Carter et al. 2017).
Several LAMP kits are commercially available in the market. For instance, the Loopamp TB detection kit, Trypanosoma brucei kit, L. monocytogenes detection kit, Legionella screening kit E for environmental detection, Malaria kit, SARS Coronavirus detection kit, Campylobacter detection kit, M. pneumoniae detection kit, E. coli O157 detection kit, Cryptosporidium detection kit, and Bovine Embryo Sex Typing Kit are all currently available from Eiken Chemical Co., Ltd. In 2010, another LAMP assay to detect C. difficile was developed by Meridian Bioscience USA, termed as illumigene ® C. difficile. It was welcomed by many researchers due to its high sensitivity for detecting C. difficile (Pancholi et al. 2012).
LAMP primer sets are also commercially available from Eiken Chemical Co., Ltd, such as the Loopamp primer set for the West Nile virus; Avian flu H5 and H7; FluA influenza; Flavobacterium psychrophilum and Alicyclobacilus acidoterrestris.
Advantages of LAMP
As suggested by WHO, the criteria for an ideal diagnostic test must comprise sensitivity, specificity, low‐cost, simplicity, rapidity, adaptability to all kinds of climatic changes and the availability of instruments (Mabey et al. 2004). Since detection of diseases is becoming progressively more difficult due to the occurrence of new as well as existing disease or pathogens, an alternative diagnostic method is in need to be discovered. Among the amplification techniques, LAMP stands out an effective diagnostic test. It is a preferred diagnostic tool, even though its principle and reaction mechanism is slightly complex (Notomi et al. 2015). Ever since its development, the striking properties of LAMP have encouraged researchers to further explore its usage for analysis in various fields.
As been discussed in this paper, LAMP could be one of the diagnostic method alternative in relation to its rapidity, sensitivity (Ishiguro et al. 2015; Kumvongpin et al. 2016; Besuschio et al. 2017) and specificity. The most significant advantage of LAMP would be its rapidity where LAMP allows immediate diagnosis. Unlike any other nucleic acid amplification technique, for example, PCR, LAMP could be performed in just 30 min rather than at least 90 min for PCR. In addition, a LAMP amplification proceeds rapidly since the initial heat denaturation for the DNA template is not required.
Another advantage of LAMP would be its simplicity to be performed where all it needs is a simple water bath or heating block that provides an isothermal condition. This eliminates the need of advanced instruments as needed in other amplification technique. LAMP has the potential to improve molecular biology technology with the simplicity of the assay as it is much easier to use as compared with PCR. The simplicity of LAMP can also be described in the method of analysing the results. Direct evaluation of results were made possible whereby the dyes used in LAMP reactions enable naked eye observation of colorimetric changes be it under natural light or UV light with the use of fluorescence dye. Thus, unlike PCR, tedious gel electrophoresis procedure of the amplification products is not needed.
Apart from that, a new pH sensitive dye for LAMP was recently developed by taking into consideration the unique features of Bst DNA polymerase in buffered solutions. Since a significant pH change from alkaline to acidic was observed during LAMP amplification, pH indicator dyes can be used to monitor the LAMP reaction and a significant colour change was easily visualized (Tanner et al. 2015). This helps to further improve the flexibility of LAMP as a simple tool for use in endemic countries. LAMP assays also appeared unaffected by the presence of nontarget DNA in the acquired samples (Kaneko et al. 2007; Lin et al. 2012) which resembles its high specificity characteristic. The LAMP assay is stable against some PCR inhibitors such as blood and detection can be performed without the template extraction step and with a nonprocessed sample (Nagamine et al. 2001; Francois et al. 2011; Lin et al. 2012; Mori et al. 2013; Wang et al. 2013).
As LAMP advances, it can be made into a portable device to ease transportation to the site of diagnosis, for example, the diagnosis of the Ebola virus and food‐borne pathogens (Uddin et al. 2015; Kurosaki et al. 2016; Safavieh et al. 2016). On top of that, LAMP can amplify RNA with high efficiency by using reverse transcriptase (Mori et al. 2001; Nagamine et al. 2002; Dukes et al. 2006). At present, improved DNA polymerases, such as Bst 3.0 polymerase and OmniAmp polymerase, are available for the application of LAMP and RT‐LAMP. These DNA polymerases demonstrated a robust performance with increase reverse transcriptase activity as compared to conventional Bst DNA polymerase (Chander et al. 2014; Tian et al. 2016).
Limitations of LAMP
Despite the robustness of this novel technique, there are a few limitations that could impede its smooth application. This technique is inapplicable for cloning or other molecular biology purposes since the final product is a large DNA chain, making it to be less versatile when compared to PCR (Sahoo et al. 2016). Furthermore, the multiplexing approaches of LAMP is still considered less successful than PCR as they increase the difficulty of the experimental design and procedures (Dhama et al. 2014).
It is also challenging to choose a correct and proper target for amplification, for either a highly conserved region or target site which is specific to a particular strain of micro‐organism. Furthermore, in order to increase the sensitivity and specificity, LAMP uses 4–6 primers targeting 6 or 8 regions within a rather small segment of target sequence. Therefore, the primer design is exposed to many restrictions and it is problematic to design a LAMP primer. Even though a free online software is available to help with primer design, however, under certain circumstances, some of the preferred target sites might not be selected and, thus, would still rely on the need to manually design the primers. The usage of multiple primers will increase the chances of primer–primer hybridizations leading to template‐free amplification, giving false‐positive results (Watts et al. 2014), but the chances of false positivity require further investigation. In the case of the aforementioned phenomenon occurs, it is recommended to redesign the primers.
One major drawback of LAMP is its high risk of carryover contamination which often leads to false‐positive results in negative controls (Hsieh et al. 2014; Karthik et al. 2014). This is due to the extremely high efficiency of the LAMP reaction. The LAMP product is so stable that it is not degraded easily and thus unintended carryover contamination can occurs (Bi et al. 2012; Dhama et al. 2014; Fischbach et al. 2015). In case aforesaid contamination occurs, it is suggested to perform LAMP in a laminar flow hood and use separate pipettes and filtered tips. For procedures that involved opening of the reaction tubes, for example, gel electrophoresis, it is wise to carry out LAMP in an isolated room as LAMP is highly sensitive to even minute amounts of product contamination.
The turbidimetric and colorimetric determination of the LAMP reaction is subjective when determined by visual observation alone, as it relies on an individual's perception of colour (Bista et al. 2007). Furthermore, the product of LAMP results in a ladder pattern or smearing on the gel rather than a single band as in PCR, thus identification of a target by size of the band on a gel is not possible with LAMP (Wastling et al. 2010).
Future potential of LAMP
The significant characteristics of LAMP are easy handling – it only needs a simple water bath at a constant temperature and its rapidity. Developing a mobile biosensor with LAMP technology application may result in a significant advancement. To date, LAMP was widely used as a diagnostic tool for the detection of human, livestock and plant diseases. However, there are few publications on the use of this technique for the direct detection of environmental pathogens. The development of a sensor that can detect the presence of pathogenic pathogens directly from an environmental sample may bring vast benefits, especially in diseases that are caused by environmental pathogens, such as Leptospirosis. Apart from that, LAMP could also be applied in the early detection of genetic diseases in a foetus, for instance, Down syndrome and thalassemia, as it has high specificity. The development of microfluidic devices with LAMP also comes with many advantages, such as easy to operate, palm‐sized, high output applicability, decrease in the consumption of expensive reagents and do not require electricity. LAMP microfluidic devices are commonly developed for food testing, cancer screening and virus detection. In summary, all of the features of LAMP prove that its straightforwardness is beneficial for the on‐site field or diagnostics in an everyday basis in a POC setting.
Conclusion
LAMP is a ground‐breaking gene amplification technique. It works as a fast and simple diagnostic tool for the quick detection and identification of microbiological infections. Besides being simple to operate and easily adapted to any field circumstances and environments, LAMP has all the features required for real‐time assays, especially in high sensitivity. LAMP is also a beneficial and valuable tool for use in developing countries due to its ease of performance without needing any advanced equipment or experts to operate it. In summary, LAMP could be the ideal diagnostic method, as it fulfils all criteria proposed by the WHO on ideal diagnostics.
Conflict of Interest
No conflict of interest declared. All authors read and approved the final version of the manuscript.
Acknowledgements
A special thanks to Lam Jia Yong for proofreading this manuscript. We also acknowledge Long Term Research Grant Scheme by Ministry of Higher Education Malaysia (UPM/700‐2/1/LRGS/5526400). Graduate student support for research works was provided by a Graduate Research Fellowship (GRF) from the Universiti Putra Malaysia and MyBrain15 from the Ministry of Higher Education Malaysia.
Yien‐Ping Wong and Shuhaidah Othman contributed equally.
References
- Abdullah, J. , Saffie, N. , Sjasri, F.A. , Husin, A. , Abdul‐Rahman, Z. , Ismail, A. , Aziah, I. and Mohamed, M. (2014) Rapid detection of Salmonella Typhi by loop‐mediated isothermal amplification (LAMP) method. Braz J Microbiol 45, 1385–1391. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Ahmed, M.E. , Eldigail, M.H. , Elamin, F.M. , Ali, I.A. , Grobusch, M.P. and Aradaib, I.E. (2016) Development and evaluation of real‐time loop‐mediated isothermal amplification assay for rapid detection of cystic echinococcosis. BMC Vet Res 12, 202. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Aonuma, H. , Yoshimura, A. , Kobayashi, T. , Okado, K. , Badolo, A. , Nelson, B. , Kanuka, H. and Fukumoto, S. (2010) A single fluorescence‐based LAMP reaction for identifying multiple parasites in mosquitoes. Exp Parasitol 125, 179–183. [DOI] [PubMed] [Google Scholar]
- Bakhtiari, S. , Alvandi, A. , Pajavand, H. , Navabi, J. , Najafi, F. and Abiri, R. (2016) Development and diagnostic evaluation of loop‐mediated isothermal amplification using a new gene target for rapid detection of Helicobacter pylori . Jundishapur J Microbiol 9, e28831. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Balne, P.K. , Basu, S. , Rath, S. , Barik, M.R. and Sharma, S. (2015) Loop mediated isothermal amplification assay using hydroxy naphthol blue, conventional polymerase chain reaction and real‐time PCR in the diagnosis of intraocular tuberculosis. Indian J Med Microbiol 33, 568–571. [DOI] [PubMed] [Google Scholar]
- Bao, H. , Feng, X. , Ma, Y. , Shi, J. , Zhao, Y. , Gu, L. , Wang, X. and Chen, H. (2015) Rapid detection of subtype H10N8 influenza virus by one‐step reverse transcription‐loop‐mediated isothermal amplification methods. J Clin Microbiol 53, 3884–3887. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Batra, K. , Kumar, A. , Kumar, V. , Nanda, T. , Maan, N.S. and Maan, S. (2015) Development and evaluation of loop‐mediated isothermal amplification assay for rapid detection of Capripoxvirus. Vet World 8, 1286–1292. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Bentaleb, E.M. , Abid, M. , el Messaoudi, M.D. , Lakssir, B. , Ressami, E.M. , Amzazi, S. , Sefrioui, H. and Ait Benhassou, H. (2016) Development and evaluation of an in‐house single step loop‐mediated isothermal amplification (SS‐LAMP) assay for the detection of Mycobacterium tuberculosis complex in sputum samples from Moroccan patients. BMC Infect Dis 16, 517. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Besuschio, S. A. , Llano Murcia, M. , Benatar, A. F. , Monnerat, S. , Cruz Mata, I. , de Picado Puig, A. , Curto, M. L. A. , Kubota, Y. et al (2017). Analytical sensitivity and specificity of a loop‐mediated isothermal amplification (LAMP) kit prototype for detection of Trypanosoma cruzi DNA in human blood samples. PLoS Negl Trop Dis, 11, e0005779. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Bi, A. , Nakajima, C. , Fukushima, Y. , Tamaru, A. , Sugawara, I. , Kimura, A. , Kawahara, R. , Hu, Z. et al (2012) A rapid loop‐mediated isothermal amplification assay targeting hspX for the detection of Mycobacterium tuberculosis complex. Jpn J Infect Dis 65, 247–251. [DOI] [PubMed] [Google Scholar]
- Birmpa, A. , Kalogeropoulos, K. , Kokkinos, P. and Vantarakis, A. (2015) Evaluation of two loop‐mediated isothermal amplification methods for the detection of Salmonella enteritidis and Listeria Monocytogenes in artificially contaminated ready‐to‐eat fresh produce. Ital J Food Saf 4, 5383. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Bista, B.R. , Ishwad, C. , Wadowsky, R.M. , Manna, P. , Randhawa, P.S. , Gupta, G. , Adhikari, M. , Tyagi, R. et al (2007) Development of a loop‐mediated isothermal amplification assay for rapid detection of BK virus. J Clin Microbiol 45, 1581–1587. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Britton, S. , Cheng, Q. , Grigg, M.J. , William, T. , Anstey, N.M. and McCarthy, J.S. (2016) A sensitive, colorimetric, high‐throughput loop‐mediated isothermal amplification assay for the detection of Plasmodium knowlesi . Am J Trop Med Hyg 95, 120–122. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Brotons, P. , de Paz, H.D. , Esteva, C. , Latorre, I. and Munoz‐Almagro, C. (2016) Validation of a loop‐mediated isothermal amplification assay for rapid diagnosis of pertussis infection in nasopharyngeal samples. Expert Rev Mol Diagn 16, 125–130. [DOI] [PubMed] [Google Scholar]
- Carter, C. , Akrami, K. , Hall, D. , Smith, D. and Aronoff‐Spencer, E. (2017) Lyophilized visually readable loop‐mediated isothermal reverse transcriptase nucleic acid amplification test for detection Ebola Zaire RNA. J Virol Methods 244, 32–38. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Chander, Y. , Koelbl, J. , Puckett, J. , Moser, M.J. , Klingele, A.J. , Liles, M.R. , Carrias, A. , Mead, D.A. et al (2014) A novel thermostable polymerase for RNA and DNA loop‐mediated isothermal amplification (LAMP). Front Microbiol 5, 395. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Chen, H.W. , Weissenberger, G. , Atkins, E. , Chao, C.C. , Suputtamongkol, Y. and Ching, W.M. (2015) Highly sensitive loop‐mediated isothermal amplification for the detection of Leptospira . Int J Bacteriol 2015, 147173. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Chen, H.W. , Weissenberger, G. and Ching, W.M. (2016) Development of lyophilized loop‐mediated isothermal amplification reagents for the detection of Leptospira . Mil Med 181, 227–231. [DOI] [PubMed] [Google Scholar]
- Chen, L. , Jiao, Z. , Liu, D. , Liu, X. , Xia, Z. , Deng, C. , Zhou, T. and Fan, Z. (2017a) One‐step reverse transcription loop‐mediated isothermal amplification for the detection of Maize chlorotic mottle virus in maize. J Virol Methods 240, 49–53. [DOI] [PubMed] [Google Scholar]
- Chen, C. , Zhao, Q. , Guo, J. , Li, Y. and Chen, Q. (2017b) Identification of methicillin‐resistant Staphylococcus aureus (MRSA) using simultaneous detection of mecA, nuc, and femB by loop‐mediated isothermal amplification (LAMP). Curr Microbiol 74, 965–971. [DOI] [PubMed] [Google Scholar]
- Choopara, I. , Arunrut, N. , Kiatpathomchai, W. , Dean, D. and Somboonna, N . (2016) Rapid and visual Chlamydia trachomatis detection using loop‐mediated isothermal amplification and hydroxynaphthal blue. Lett Appl Microbiol 64, 51–56. [DOI] [PubMed] [Google Scholar]
- Chotiwan, N. , Brewster, C. D. , Magalhaes, T. , Weger‐Lucarelli, J. , Duggal, N. K. , Rückert, C. , Nguyen, C. , Garcia Luna, S. M. et al (2017). Rapid and specific detection of Asian‐ and African‐lineage Zika viruses. Sci Transl Med, 3, 9. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Chowdry, V.K. , Luo, Y. , Widen, F. , Qiu, H.J. , Shan, H. , Belak, S. and Liu, L. (2014) Development of a loop‐mediated isothermal amplification assay combined with a lateral flow dipstick for rapid and simple detection of classical swine fever virus in the field. J Virol Methods 197, 14–18. [DOI] [PubMed] [Google Scholar]
- Damhorst, G.L. , Duarte‐Guevara, C. , Chen, W. , Ghonge, T. , Cunningham, B.T. and Bashir, R. (2015) Smartphone‐imaged HIV‐1 reverse‐transcription loop‐mediated isothermal amplification (RT‐LAMP) on a chip from whole blood. Engineering 1, 324–335. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Deng, J. , Pei, J. , Gou, H. , Ye, Z. , Liu, C. and Chen, J. (2015) Rapid and simple detection of Japanese encephalitis virus by reverse transcription loop‐mediated isothermal amplification combined with a lateral flow dipstick. J Virol Methods 213, 98–105. [DOI] [PubMed] [Google Scholar]
- Dhama, K. , Karthik, K. , Chakraborty, S. , Tiwari, R. , Kapoor, S. , Kumar, A. and Thomas, P. (2014) Loop‐mediated isothermal amplification of DNA (LAMP): a new diagnostic tool lights the world of diagnosis of animal and human pathogens: a review. Pak J Biol Sci 17, 151–166. [DOI] [PubMed] [Google Scholar]
- Draz, M.S. and Lu, X. (2016) Development of a Loop Mediated Isothermal Amplification (LAMP) ‐ Surface Enhanced Raman spectroscopy (SERS) Assay for the Detection of Salmonella Enterica Serotype Enteritidis. Theranostics 6, 522–532. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Dukes, J.P. , King, D.P. and Alexandersen, S. (2006) Novel reverse transcription loop‐mediated isothermal amplification for rapid detection of foot‐and‐mouth disease virus. Arch Virol 151, 1093–1106. [DOI] [PubMed] [Google Scholar]
- Elvira‐Gonzalez, L. , Puchades, A.V. , Carpino, C. , Alfaro‐Fernandez, A. , Font‐San‐ambrosio, M.I. , Rubio, L. and Galipienso, L. (2017) Fast detection of Southern tomato virus by one‐step transcription loop‐mediated isothermal amplification (RT‐LAMP). J Virol Methods 241, 11–14. [DOI] [PubMed] [Google Scholar]
- Fahy, E. , Kwoh, D.Y. and Gingeras, T.R. (1991) Self‐sustained sequence replication (3SR): an isothermal transcription‐based amplification system alternative to PCR. PCR Methods Appl 1, 25–33. [DOI] [PubMed] [Google Scholar]
- Fan, F. , Du, P. , Kan, B. and Yan, M. (2015) The development and evaluation of a loop‐mediated isothermal amplification method for the rapid detection of Salmonella enterica serovar Typhi. PLoS ONE 10, e0124507. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Fang, X.‐E. , Li, J. and Chen, Q. (2008) One new method of nucleic acid amplification—Loop‐mediated isothermal amplification of DNA. Virol Sin 23, 167–172. [Google Scholar]
- Fischbach, J. , Xander, N.C. , Frohme, M. and Glokler, J.F. (2015) Shining a light on LAMP assays – A comparison of LAMP visualization methods including the novel use of berberine. Biotechniques 58, 189–194. [DOI] [PubMed] [Google Scholar]
- Fowler, V.L. , Howson, E.L. , Madi, M. , Mioulet, V. , Caiusi, C. , Pauszek, S.J. , Rodriguez, L.L. and King, D.P. (2016) Development of a reverse transcription loop‐mediated isothermal amplification assay for the detection of vesicular stomatitis New Jersey virus: use of rapid molecular assays to differentiate between vesicular disease viruses. J Virol Methods 234, 123–131. [DOI] [PubMed] [Google Scholar]
- Francois, P. , Tangomo, M. , Hibbs, J. , Bonetti, E.J. , Boehme, C.C. , Notomi, T. , Perkins, M.D. and Schrenzel, J. (2011) Robustness of a loop‐mediated isothermal amplification reaction for diagnostic applications. FEMS Immunol Med Microbiol 62, 41–48. [DOI] [PubMed] [Google Scholar]
- Fujino, M. , Suzuki, E. , Watanabe, M. and Nakayama, T. (2015) Loop‐mediated isothermal amplification (LAMP) aids the clinical diagnosis of pertussis. Jpn J Infect Dis 68, 532–533. [DOI] [PubMed] [Google Scholar]
- Geng, H. , Wang, S. , Xie, X. , Xiao, Y. , Zhang, T. , Tan, W. and Su, C. (2016) Visual detection of human coronavirus NL63 by reverse transcription loop‐mediated isothermal amplification. Bing Du Xue Bao 32, 56–61. [PubMed] [Google Scholar]
- Guatelli, J.C. , Whitfield, K.M. , Kwoh, D.Y. , Barringer, K.J. , Richman, D.D. and Gingeras, T.R. (1990) Isothermal, in vitro amplification of nucleic acids by a multienzyme reaction modeled after retroviral replication. Proc Natl Acad Sci U S A 87, 1874–1878. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Hayashida, K. , Kajino, K. , Hachaambwa, L. , Namangala, B. and Sugimoto, C. (2015) Direct blood dry LAMP: a rapid, stable, and easy diagnostic tool for Human African Trypanosomiasis. PLoS Negl Trop Dis 9, e0003578. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Hoos, J. , Peters, R.M. , Tabatabai, J. , Grulich‐Henn, J. , Schnitzler, P. and Pfeil, J. (2017) Reverse‐transcription loop‐mediated isothermal amplification for rapid detection of respiratory syncytial virus directly from nasopharyngeal swabs. J Virol Methods 242, 53–57. [DOI] [PubMed] [Google Scholar]
- Hsieh, K. , Mage, P.L. , Csordas, A.T. , Eisenstein, M. and Soh, H.T. (2014) Simultaneous elimination of carryover contamination and detection of DNA with uracil‐DNA‐glycosylase‐supplemented loop‐mediated isothermal amplification (UDG‐LAMP). Chem Commun 50, 3747–3749. [DOI] [PubMed] [Google Scholar]
- Hsu, Y.H. , Chou, S.J. , Chang, C.C. , Pan, M.J. , Yang, W.C. , Lin, C.F. and Chan, K.W. (2017) Development and validation of a new loop‐mediated isothermal amplification for detection of pathogenic Leptospira species in clinical materials. J Microbiol Methods 141, 55–59. [DOI] [PubMed] [Google Scholar]
- Hu, S.F. , Li, M. , Zhong, L.L. , Lu, S.M. , Liu, Z.X. , Pu, J.Y. , Wen, J.S. and Huang, X. (2015) Development of reverse‐transcription loop‐mediated isothermal amplification assay for rapid detection and differentiation of dengue virus serotypes 1‐4. BMC Microbiol 15, 265. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Huang, H.L. , Zhu, P. , Zhou, C.X. , He, S. and Yan, X.J. (2017) The development of loop‐mediated isothermal amplification combined with lateral flow dipstick for detection of Karlodinium veneficum . Harmful Algae 62, 20–29. [DOI] [PubMed] [Google Scholar]
- Inoshima, Y. , Takasu, M. and Ishiguro, N. (2017) Establishment of an on‐site diagnostic procedure for detection of orf virus from oral lesions of Japanese serows (Capricornis crispus) by loop‐mediated isothermal amplification. J Vet Med Sci 78, 1841–1845. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Ishiguro, N. , Koseki, N. , Kaiho, M. , Kikuta, H. , Togashi, T. , Watanabe, T. , Ariga, T. and Hokkaido Pediatric Respiratory Infection Study Group (2015) Sensitivity and specificity of a loop‐mediated isothermal amplification assay for the detection of Mycoplasma pneumoniae from nasopharyngeal swab samples compared with those of real‐time PCR. Clin Lab 61, 603–606. [DOI] [PubMed] [Google Scholar]
- Kaewphinit, T. , Ckumdee, J. , Chansiri, K. and Santiwatanakul, S. (2017) Development and evaluation of a loop‐mediated isothermal amplification combined with au‐nanoprobe assay for rapid detection of Mycobacterium tuberculosis . Indian J Med Microbiol 35, 302–304. [DOI] [PubMed] [Google Scholar]
- Kamachi, K. , Moriuchi, T. , Hiramatsu, Y. , Otsuka, N. and Shibayama, K. (2017) Evaluation of a commercial loop‐mediated isothermal amplification assay for diagnosis of Bordetella pertussis infection. J Microbiol Methods 133, 20–22. [DOI] [PubMed] [Google Scholar]
- Kaneko, H. , Kawana, T. , Fukushima, E. and Suzutani, T. (2007) Tolerance of loop‐mediated isothermal amplification to a culture medium and biological substances. J Biochem Biophys Methods 70, 499–501. [DOI] [PubMed] [Google Scholar]
- Karthik, K. , Rathore, R. , Thomas, P. , Arun, T.R. , Viswas, K.N. , Dhama, K. and Agarwal, R.K. (2014) New closed tube loop mediated isothermal amplification assay for prevention of product cross‐contamination. MethodsX 1, 137–143. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Khunthong, S. , Jaroenram, W. , Arunrut, N. , Suebsing, R. , Mungsantisuk, I. and Kiatpathomchai, W. (2013) Rapid and sensitive detection of shrimp yellow head virus by loop‐mediated isothermal amplification combined with a lateral flow dipstick. J Virol Methods 188, 51–56. [DOI] [PubMed] [Google Scholar]
- Kim, E.M. , Jeon, H.S. , Kim, J.J. , Shin, Y.K. , Lee, Y.J. , Yeo, S.G. and Park, C.K. (2016a) Uracil‐DNA glycosylase‐treated reverse transcription loop‐mediated isothermal amplification for rapid detection of avian influenza virus preventing carry‐over contamination. J Vet Sci 17, 421–425. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Kim, H.J. , Kim, H.S. , Lee, J.M. , Yoon, S.S. and Yong, D. (2016b) Rapid detection of Pseudomonas aeruginosa and Acinetobacter baumannii Harboring bla(VIM‐2), bla(IMP‐1) and bla(OXA‐23) genes by using loop‐mediated isothermal amplification methods. Ann Lab Med 36, 15–22. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Kobayashi, T. , Yagami, A. , Suzuki, K. , Yoshikawa, T. and Matsunaga, K. (2014) Concurrent reactivation of herpes simplex and varicella zoster viruses confirmed by the loop‐mediated isothermal amplification assay. Case Rep Dermatol 6, 5–9. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Kongkasuriyachai, D. , Yongkiettrakul, S. , Kiatpathomchai, W. and Arunrut, N. (2017) Loop‐mediated isothermal amplification and LFD combination for detection of Plasmodium falciparum and Plasmodium vivax . Methods Mol Biol 1572, 431–443. [DOI] [PubMed] [Google Scholar]
- Kumar, P. , Pandya, D. , Singh, N. , Behera, D. , Aggarwal, P. and Singh, S. (2014) Loop‐mediated isothermal amplification assay for rapid and sensitive diagnosis of tuberculosis. J Infect 69, 607–615. [DOI] [PubMed] [Google Scholar]
- Kumvongpin, R. , Jearanaikool, P. , Wilailuckana, C. , Sae‐Ung, N. , Prasongdee, P. , Daduang, S. , Wongsena, M. , Boonsiri, P. et al (2016) High sensitivity, loop‐mediated isothermal amplification combined with colorimetric gold‐nanoparticle probes for visual detection of high risk human papillomavirus genotypes 16 and 18. J Virol Methods 234, 90–95. [DOI] [PubMed] [Google Scholar]
- Kurosaki, Y. , Magassouba, N. , Oloniniyi, O.K. , Cherif, M.S. , Sakabe, S. , Takada, A. , Hirayama, K. and Yasuda, J. (2016) Development and evaluation of reverse transcription‐loop‐mediated isothermal amplification (RT‐LAMP) assay coupled with a portable device for rapid diagnosis of ebola virus disease in Guinea. PLoS Negl Trop Dis 10, e0004472. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Kursa, O. , Wozniakowski, G. , Tomczyk, G. , Sawicka, A. and Minta, Z. (2015) Rapid detection of Mycoplasma synoviae by loop‐mediated isothermal amplification. Arch Microbiol 197, 319–325. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Kusumawati, A. , Tampubolon, I.D. , Hendarta, N.Y. , Salasia, S.I. , Wanahari, T.A. , Mappakaya, B.A. and Hartati, S. (2015) Use of reverse transcription loop‐mediated isothermal amplification combined with lateral flow dipstick for an easy and rapid detection of Jembrana disease virus. Virusdisease 26, 189–195. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Lau, Y.L. , Lai, M.Y. , Teoh, B.T. , Abd‐Jamil, J. , Johari, J. , Sam, S.S. , Tan, K.K. and Abubakar, S. (2015) Colorimetric detection of dengue by single tube reverse‐transcription‐loop‐mediated isothermal amplification. PLoS ONE 10, e0138694. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Lau, Y.L. , Lai, M.Y. , Fong, M.Y. , Jelip, J. and Mahmud, R. (2016) Loop‐mediated isothermal amplification assay for identification of five human Plasmodium species in Malaysia. Am J Trop Med Hyg 94, 336–339. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Lee, M.F. , Chen, Y.H. , Hsu, H.J. and Peng, C.F. (2010) One‐tube loop‐mediated isothermal amplification combined with restriction endonuclease digestion and ELISA for colorimetric detection of resistance to isoniazid, ethambutol and streptomycin in Mycobacterium tuberculosis isolates. J Microbiol Methods 83, 53–58. [DOI] [PubMed] [Google Scholar]
- Lee, D. , Kim, E.J. , Kilgore, P.E. , Takahashi, H. , Ohnishi, M. , Tomono, J. , Miyamoto, S. , Omagari, D. et al (2015) A novel loop‐mediated isothermal amplification assay for serogroup identification of Neisseria meningitidis in cerebrospinal fluid. Front Microbiol 6, 1548. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Lee, S.H. , Baek, Y.H. , Kim, Y.H. , Choi, Y.K. , Song, M.S. and Ahn, J.Y. (2016) One‐pot reverse transcriptional loop‐mediated isothermal amplification (RT‐LAMP) for detecting MERS‐CoV. Front Microbiol 7, 2166. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Li, Y.‐J. and Fan, J.‐Y. (2016) Rapid visual identification of bovine meat by loop mediated isothermal amplification combined with immunochromatographic strip. BioChip J 11, 8–13. [Google Scholar]
- Li, G. , Nie, K. , Zhang, D. , Li, X. , Wang, Y. , Tan, W. and Ma, X. (2015) Detection of middle east respiratory syndrome coronavirus by reverse‐transcription loop‐mediated isothermal amplification. Bing Du Xue Bao 31, 269–275. [PubMed] [Google Scholar]
- Lin, Z. , Zhang, Y. , Zhang, H. , Zhou, Y. , Cao, J. and Zhou, J. (2012) Comparison of loop‐mediated isothermal amplification (LAMP) and real‐time PCR method targeting a 529‐bp repeat element for diagnosis of toxoplasmosis. Vet Parasitol 185, 296–300. [DOI] [PubMed] [Google Scholar]
- Lin, F. , Liu, L. , Hao, G.J. , Cao, Z. , Sheng, P.C. , Wu, Y.L. and Shen, J.Y. (2014) Rapid detection of Macrobrachium rosenbergii nodavirus isolated in China by a reverse‐transcription loop‐mediated isothermal amplification assay combined with a lateral flow dipstick method. Bing Du Xue Bao 30, 502–507. [PubMed] [Google Scholar]
- Lin, M. , Liu, W. , Wang, P. , Tan, J. , Zhou, Y. , Wu, P. , Zhang, T. , Yuan, J. et al (2015) Rapid detection of ermB gene in Clostridium difficile by loop‐mediated isothermal amplification. J Med Microbiol 64, 854–861. [DOI] [PubMed] [Google Scholar]
- Lin, J. , Ma, B. , Fang, J. , Wang, Y. , He, H. , Lin, W. , Su, W. and Zhang, M. (2017) Colorimetric detection of 23 human papillomavirus genotypes by loop‐mediated isothermal amplification. Clin Lab 63, 495–505. [DOI] [PubMed] [Google Scholar]
- Liu, Y. , Tang, J.M. , Tao, H. , Sun, J. , Lu, T.K. , Liao, L.S. , Liu, J.L. , Zeng, S.L. et al (2013) Establish and optimization of real‐time fluorescent reverse transcription loop‐mediated isothermal amplification for detection of avian influenza H5 hemagglutinin gene. Bing Du Xue Bao 29, 488–494. [PubMed] [Google Scholar]
- Liu, H. , Li, X.T. , Hu, B. , Zhang, L. , Xue, X.H. , Lv, S. , Lu, R.G. , Shi, N. et al (2016) Development of reverse transcription loop‐mediated isothermal amplification for rapid detection of batai virus in cattle and mosquitoes. Vector Borne Zoonotic Dis 16, 415–422. [DOI] [PubMed] [Google Scholar]
- Liu, N. , Zou, D. , Dong, D. , Yang, Z. , Ao, D. , Liu, W. and Huang, L . (2017) Development of a multiplex loop‐mediated isothermal amplification method for the simultaneous detection of Salmonella spp. and Vibrio parahaemolyticus . Sci Rep, 7, 45601. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Lucchi, N.W. , Ljolje, D. , Silva‐Flannery, L. and Udhayakumar, V. (2016) Use of malachite green‐loop mediated isothermal amplification for detection of Plasmodium spp. parasites. PLoS ONE 11, e0151437. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Luo, J. , Taniwaki, M.H. , Iamanaka, B.T. , Vogel, R.F. and Niessen, L. (2014) Application of loop‐mediated isothermal amplification assays for direct identification of pure cultures of Aspergillus flavus, A. nomius, and A. caelatus and for their rapid detection in shelled Brazil nuts. Int J Food Microbiol 172, 5–12. [DOI] [PubMed] [Google Scholar]
- Mabey, D. , Peeling, R.W. , Ustianowski, A. and Perkins, M.D. (2004) Diagnostics for the developing world. Nat Rev Microbiol 2, 231–240. [DOI] [PubMed] [Google Scholar]
- Malek, L. , Sooknanan, R. and Compton, J. (1994) Nucleic acid sequence‐based amplification (NASBA). Methods Mol Biol 28, 253–260. [DOI] [PubMed] [Google Scholar]
- Mashooq, M. , Kumar, D. , Niranjan, A.K. , Agarwal, R.K. and Rathore, R. (2016) Development and evaluation of probe based real time loop mediated isothermal amplification for Salmonella: a new tool for DNA quantification. J Microbiol Methods 126, 24–29. [DOI] [PubMed] [Google Scholar]
- Monazah, A. , Zeinoddini, M. and Saeeidinia, A.R. (2017) Evaluation of a rapid detection for Coxsackievirus B3 using one‐step reverse transcription loop‐mediated isothermal amplification (RT‐LAMP). J Virol Methods 246, 27–33. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Mori, Y. , Nagamine, K. , Tomita, N. and Notomi, T. (2001) Detection of loop‐mediated isothermal amplification reaction by turbidity derived from magnesium pyrophosphate formation. Biochem Biophys Res Commun 289, 150–154. [DOI] [PubMed] [Google Scholar]
- Mori, Y. , Kanda, H. and Notomi, T. (2013) Loop‐mediated isothermal amplification (LAMP): recent progress in research and development. J Infect Chemother 19, 404–411. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Mugambi, R.M. , Agola, E.L. , Mwangi, I.N. , Kinyua, J. , Shiraho, E.A. and Mkoji, G.M. (2015) Development and evaluation of a loop mediated isothermal amplification (LAMP) technique for the detection of hookworm (Necator americanus) infection in fecal samples. Parasit Vectors 8, 574. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Mwendwa, F. , Mbae, C.K. , Kinyua, J. , Mulinge, E. , Mburugu, G.N. and Njiru, Z.K. (2017) Stem loop‐mediated isothermal amplification test: comparative analysis with classical LAMP and PCR in detection of Entamoeba histolytica in Kenya. BMC Res Notes 10, 142. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Nagai, Y. , Iwade, Y. , Nakano, M. , Akachi, S. , Kobayashi, T. and Nishinaka, T. (2016) Rapid and simple identification of Beijing genotype strain of Mycobacterium tuberculosis using a loop‐mediated isothermal amplification assay. Microbiol Immunol 60, 459–467. [DOI] [PubMed] [Google Scholar]
- Nagamine, K. , Watanabe, K. , Ohtsuka, K. , Hase, T. and Notomi, T. (2001) Loop‐mediated isothermal amplification reaction using a nondenatured template. Clin Chem 47, 1742–1743. [PubMed] [Google Scholar]
- Nagamine, K. , Hase, T. and Notomi, T. (2002) Accelerated reaction by loop‐mediated isothermal amplification using loop primers. Mol Cell Probes 16, 223–229. [DOI] [PubMed] [Google Scholar]
- Nakano, R. , Nakano, A. , Ishii, Y. , Ubagai, T. , Kikuchi‐Ueda, T. , Kikuchi, H. , Tansho‐Nagakawa, S. , Kamoshida, G. et al (2015) Rapid detection of the Klebsiella pneumoniae carbapenemase (KPC) gene by loop‐mediated isothermal amplification (LAMP). J Infect Chemother 21, 202–206. [DOI] [PubMed] [Google Scholar]
- Nakashima, K. , Aoshima, M. , Ohkuni, Y. , Hoshino, E. , Hashimoto, K. and Otsuka, Y. (2014) Loop‐mediated isothermal amplification method for diagnosing Pneumocystis pneumonia in HIV‐uninfected immunocompromised patients with pulmonary infiltrates. J Infect Chemother 20, 757–761. [DOI] [PubMed] [Google Scholar]
- Nakauchi, M. , Takayama, I. , Takahashi, H. , Tashiro, M. and Kageyama, T. (2014) Development of a reverse transcription loop‐mediated isothermal amplification assay for the rapid diagnosis of avian influenza A (H7N9) virus infection. J Virol Methods 204, 101–104. [DOI] [PubMed] [Google Scholar]
- Nakayama, T. , Yamazaki, T. , Yo, A. , Tone, K. , Mahdi AlShahni, M. , Fujisaki, R. and Makimura, K . (2017) Detection of fungi from an indoor environment using loop‐mediated isothermal amplification (LAMP) method. Biocontrol Sci, 22, 97–104. [DOI] [PubMed] [Google Scholar]
- Nawattanapaiboon, K. , Prombun, P. , Santanirand, P. , Vongsakulyanon, A. , Srikhirin, T. , Sutapun, B. and Kiatpathomchai, W. (2016) Hemoculture and direct sputum detection of mecA‐mediated methicillin‐resistant Staphylococcus aureus by loop‐mediated isothermal amplification in combination with a lateral‐flow dipstick. J Clin Lab Anal 30, 760–767. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Niihara, H. , Kohno, K. , Tobita, R. , Ishikawa, N. and Morita, E. (2017) Rapid diagnosis of herpes zoster by loop‐mediated isothermal amplification in a pregnant woman showing folliculitis‐like eruption without vesicles. J Dermatol 44, e174–e175. [DOI] [PubMed] [Google Scholar]
- Nkouawa, A. , Sako, Y. , Okamoto, M. and Ito, A. (2016) Simple identification of human Taenia species by multiplex loop‐mediated isothermal amplification in combination with dot enzyme‐linked immunosorbent assay. Am J Trop Med Hyg 94, 1318–1323. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Notomi, T. , Okayama, H. , Masubuchi, H. , Yonekawa, T. , Watanabe, K. , Amino, N. and Hase, T. (2000) Loop‐mediated isothermal amplification of DNA. Nucleic Acids Res 28, E63. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Notomi, T. , Mori, Y. , Tomita, N. and Kanda, H. (2015) Loop‐mediated isothermal amplification (LAMP): principle, features, and future prospects. J Microbiol 53, 1–5. [DOI] [PubMed] [Google Scholar]
- Nurul Najian, A. B. , Engku Nur Syafirah, E. A. , Ismail, N. , Mohamed, M. and Yean, C. Y . (2016). Development of multiplex loop mediated isothermal amplification (m‐LAMP) label‐based gold nanoparticles lateral flow dipstick biosensor for detection of pathogenic Leptospira . Anal Chim Acta, 903, 142–148. [DOI] [PubMed] [Google Scholar]
- Nyan, D.C. and Swinson, K.L. (2016) A method for rapid detection and genotype identification of hepatitis C virus 1‐6 by one‐step reverse transcription loop‐mediated isothermal amplification. Int J Infect Dis 43, 30–36. [DOI] [PubMed] [Google Scholar]
- Nzelu, C.O. , Gomez, E.A. , Caceres, A.G. , Sakurai, T. , Martini‐Robles, L. , Uezato, H. , Mimori, T. , Katakura, K. et al (2014) Development of a loop‐mediated isothermal amplification method for rapid mass‐screening of sand flies for Leishmania infection. Acta Trop 132, 1–6. [DOI] [PubMed] [Google Scholar]
- Nzelu, C.O. , Caceres, A.G. , Guerrero‐Quincho, S. , Tineo‐Villafuerte, E. , Rodriquez‐Delfin, L. , Mimori, T. , Uezato, H. , Katakura, K. et al (2016) A rapid molecular diagnosis of cutaneous leishmaniasis by colorimetric malachite green‐loop‐mediated isothermal amplification (LAMP) combined with an FTA card as a direct sampling tool. Acta Trop 153, 116–119. [DOI] [PubMed] [Google Scholar]
- Ocwieja, K.E. , Sherrill‐Mix, S. , Liu, C. , Song, J. , Bau, H. and Bushman, F.D. (2015) A reverse transcription loop‐mediated isothermal amplification assay optimized to detect multiple HIV subtypes. PLoS ONE 10, e0117852. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Odari, E.O. , Maiyo, A. , Lwembe, R. , Gurtler, L. , Eberle, J. and Nitschko, H. (2015) Establishment and evaluation of a loop‐mediated isothermal amplification (LAMP) assay for the semi‐quantitative detection of HIV‐1 group M virus. J Virol Methods 212, 30–38. [DOI] [PubMed] [Google Scholar]
- Oloniniyi, O.K. , Kurosaki, Y. , Miyamoto, H. , Takada, A. and Yasuda, J. (2017) Rapid detection of all known ebolavirus species by reverse transcription‐loop‐mediated isothermal amplification (RT‐LAMP). J Virol Methods 246, 8–14. [DOI] [PubMed] [Google Scholar]
- Oscorbin, I.P. , Belousova, E.A. , Zakabunin, A.I. , Boyarskikh, U.A. and Filipenko, M.L. (2016) Comparison of fluorescent intercalating dyes for quantitative loop‐mediated isothermal amplification (qLAMP). Biotechniques 61, 20–25. [DOI] [PubMed] [Google Scholar]
- Pancholi, P. , Kelly, C. , Raczkowski, M. and Balada‐Llasat, J.M. (2012) Detection of toxigenic Clostridium difficile: comparison of the cell culture neutralization, Xpert C. difficile, Xpert C. difficile/Epi, and Illumigene C. difficile assays. J Clin Microbiol 50, 1331–1335. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Parida, M. , Sannarangaiah, S. , Dash, P.K. , Rao, P.V. and Morita, K. (2008) Loop mediated isothermal amplification (LAMP): a new generation of innovative gene amplification technique; perspectives in clinical diagnosis of infectious diseases. Rev Med Virol 18, 407–421. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Park, B.H. , Oh, S.J. , Jung, J.H. , Choi, G. , Seo, J.H. , Kim, D.H. , Lee, E.Y. and Seo, T.S. (2017) An integrated rotary microfluidic system with DNA extraction, loop‐mediated isothermal amplification, and lateral flow strip based detection for point‐of‐care pathogen diagnostics. Biosens Bioelectron 91, 334–340. [DOI] [PubMed] [Google Scholar]
- Peng, D. , Xie, J. , Qiang, W. , Ling, K.S. , Guo, L. , Fan, Z. and Zhou, T. (2017) One‐step reverse transcription loop‐mediated isothermal amplification assay for detection of Apple chlorotic leaf spot virus. J Virol Methods 248, 154–158. [DOI] [PubMed] [Google Scholar]
- Pham, N.T. , Trinh, Q.D. , Khamrin, P. , Ukarapol, N. , Kongsricharoern, T. , Yamazaki, W. , Komine‐Aizawa, S. , Okitsu, S. et al (2015) Loop‐mediated isothermal amplification (LAMP) for detection of Campylobacter jejuni and C. coli in Thai children with diarrhea. Jpn J Infect Dis 68, 432–433. [DOI] [PubMed] [Google Scholar]
- Plaon, S. , Longyant, S. , Sithigorngul, P. and Chaivisuthangkura, P. (2015) Rapid and sensitive detection of Vibrio alginolyticus by loop‐mediated isothermal amplification combined with a lateral flow dipstick targeted to the rpoX gene. J Aquat Anim Health 27, 156–163. [DOI] [PubMed] [Google Scholar]
- Poole, C.B. , Ettwiller, L. , Tanner, N.A. , Evans Jr, T.C. , Wanji, S. and Carlow, C. K . (2015) Genome filtering for new DNA biomarkers of Loa loa infection suitable for loop‐mediated isothermal amplification. PLoS ONE, 10, e0139286. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Radhika, B. , Kumar, N.V. and Sreenivasulu, D. (2016) Detection of Clostridium perfringens alpha toxin gene in lambs by loop mediated isothermal amplification. Vet World 9, 60–64. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Reyes, J.C. , Solon, J.A. and Rivera, W.L. (2014) Development of a loop‐mediated isothermal amplification assay for detection of Trichomonas vaginalis . Diagn Microbiol Infect Dis 79, 337–341. [DOI] [PubMed] [Google Scholar]
- Rivera, W.L. and Ong, V.A. (2013) Development of loop‐mediated isothermal amplification for rapid detection of Entamoeba histolytica . Asian Pac J Trop Med 6, 457–461. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Safavieh, M. , Kanakasabapathy, M.K. , Tarlan, F. , Ahmed, M.U. , Zourob, M. , Asghar, W. and Shafiee, H. (2016) Emerging loop‐mediated isothermal amplification‐based microchip and microdevice technologies for nucleic acid detection. ACS Biomater Sci Eng 2, 278–294. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Sahoo, P.R. , Sethy, K. , Mohapatra, S. and Panda, D. (2016) Loop mediated isothermal amplification: an innovative gene amplification technique for animal diseases. Vet World 9, 465–469. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Sakai, J. , Maeda, T. , Tarumoto, N. , Misawa, K. , Tamura, S. , Imai, K. , Yamaguchi, T. , Iwata, S. et al (2017) A novel detection procedure for mutations in the 23S rRNA gene of Mycoplasma pneumoniae with peptide nucleic acid‐mediated loop‐mediated isothermal amplification assay. J Microbiol Methods 141, 90–96. [DOI] [PubMed] [Google Scholar]
- Salinas, N.R. and Little, D.P. (2012) Electric LAMP: virtual loop‐mediated isothermal amplification. ISRN Bioinform 2012, 696758. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Santiago‐Felipe, S. , Tortajada‐Genaro, L.A. , Carrascosa, J. , Puchades, R. and Maquieira, A. (2016) Real‐time loop‐mediated isothermal DNA amplification in compact disc micro‐reactors. Biosens Bioelectron 79, 300–306. [DOI] [PubMed] [Google Scholar]
- Seesom, W. , Thongket, P. , Rattanathanawan, K. , Mekseepralard, C. and Sukhumsirichart, W. (2015) Detection of pathogenic leptospires by loop‐mediated isothermal amplification targeting LipL32 gene. J Med Assoc Thai 98(Suppl 9), S78–S84. [PubMed] [Google Scholar]
- Seki, M. , Yamashita, Y. , Torigoe, H. , Tsuda, H. , Sato, S. and Maeno, M. (2005) Loop‐mediated isothermal amplification method targeting the lytA gene for detection of Streptococcus pneumoniae . J Clin Microbiol 43, 1581–1586. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Sethi, S. , Dhaliwal, L. , Dey, P. , Kaur, H. , Yadav, R. and Sethi, S. (2016) Loop‐mediated isothermal amplification assay for detection of Mycobacterium tuberculosis complex in infertile women. Indian J Med Microbiol 34, 322–327. [DOI] [PubMed] [Google Scholar]
- Sharma, K. , Sharma, M. , Batra, N. , Sharma, A. and Dhillon, M. S . (2016) Diagnostic potential of multi‐targeted LAMP (loop‐mediated isothermal amplification) for osteoarticular tuberculosis. J Orthop Res, 35, 361–365 [DOI] [PubMed] [Google Scholar]
- Shi, W. , Li, K. , Ji, Y. , Jiang, Q. , Shi, M. and Mi, Z. (2011) Development and evaluation of reverse transcription‐loop‐mediated isothermal amplification assay for rapid detection of enterovirus 71. BMC Infect Dis 11, 197. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Siddique, M.P. , Jang, W.J. , Lee, J.M. , Ahn, S.H. , Suraiya, S. , Kim, C.H. and Kong, I.S. (2017) groEL is a suitable genetic marker for detecting Vibrio parahaemolyticus by loop‐mediated isothermal amplification assay. Lett Appl Microbiol 65, 106–113. [DOI] [PubMed] [Google Scholar]
- Singh, P. , Mirdha, B.R. , Ahuja, V. and Singh, S. (2013) Loop‐mediated isothermal amplification (LAMP) assay for rapid detection of Entamoeba histolytica in amoebic liver abscess. World J Microbiol Biotechnol 29, 27–32. [DOI] [PubMed] [Google Scholar]
- Singh, P. , Singh, S. , Mirdha, B.R. , Guleria, R. , Agarwal, S.K. and Mohan, A. (2015) Evaluation of loop‐mediated isothermal amplification assay for the detection of Pneumocystis jirovecii in immunocompromised patients. Mol Biol Int 2015, 819091. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Singh, R. , Singh, D.P. , Savargaonkar, D. , Singh, O.P. , Bhatt, R.M. and Valecha, N. (2017) Evaluation of SYBR green I based visual loop‐mediated isothermal amplification (LAMP) assay for genus and species‐specific diagnosis of malaria in P. vivax and P. falciparum endemic regions. J Vector Borne Dis 54, 54–60. [PubMed] [Google Scholar]
- Srisrattakarn, A. , Lulitanond, A. , Wilailuckana, C. , Charoensri, N. , Wonglakorn, L. , Saenjamla, P. , Chaimanee, P. , Daduang, J. et al (2017) Rapid and simple identification of carbapenemase genes, bla NDM, bla OXA‐48, bla VIM, bla IMP‐14 and bla KPC groups, in Gram‐negative bacilli by in‐house loop‐mediated isothermal amplification with hydroxynaphthol blue dye. World J Microbiol Biotechnol 33, 130. [DOI] [PubMed] [Google Scholar]
- Sriworarat, C. , Phumee, A. , Mungthin, M. , Leelayoova, S. and Siriyasatien, P. (2015) Development of loop‐mediated isothermal amplification (LAMP) for simple detection of Leishmania infection. Parasit Vectors 8, 591. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Stranieri, A. , Lauzi, S. , Giordano, A. and Paltrinieri, S. (2017) Reverse transcriptase loop‐mediated isothermal amplification for the detection of feline coronavirus. J Virol Methods 243, 105–108. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Stratakos, A.C. , Linton, M. , Millington, S. and Grant, I.R. (2017) A loop‐mediated isothermal amplification method for rapid direct detection and differentiation of nonpathogenic and verocytotoxigenic Escherichia coli in beef and bovine faeces. J Appl Microbiol 122, 817–828. [DOI] [PubMed] [Google Scholar]
- Suebsing, R. , Kampeera, J. , Sirithammajak, S. , Withyachumnarnkul, B. , Turner, W. and Kiatpathomchai, W. (2015) Colorimetric method of loop‐mediated isothermal amplification with the pre‐addition of calcein for detecting Flavobacterium columnare and its assessment in Tilapia Farms. J Aquat Anim Health 27, 38–44. [DOI] [PubMed] [Google Scholar]
- Sun, J. , Najafzadeh, M.J. , Vicente, V. , Xi, L. and de Hoog, G.S. (2010) Rapid detection of pathogenic fungi using loop‐mediated isothermal amplification, exemplified by Fonsecaea agents of chromoblastomycosis. J Microbiol Methods 80, 19–24. [DOI] [PubMed] [Google Scholar]
- Sun, Y.L. , Yen, C.H. and Tu, C.F. (2014) Visual detection of canine parvovirus based on loop‐mediated isothermal amplification combined with enzyme‐linked immunosorbent assay and with lateral flow dipstick. J Vet Med Sci 76, 509–516. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Tanner, N.A. , Zhang, Y. , and Evans, T.C. Jr (2015) Visual detection of isothermal nucleic acid amplification using pH‐sensitive dyes. Biotechniques 58, 59–68. [DOI] [PubMed] [Google Scholar]
- Thongkao, K. , Longyant, S. , Silprasit, K. , Sithigorngul, P. and Chaivisuthangkura, P. (2015) Rapid and sensitive detection of Vibrio harveyi by loop‐mediated isothermal amplification combined with lateral flow dipstick targeted tovhhP2 gene. Aquac Res 46, 1122–1131. [Google Scholar]
- Tian, B. , QIU, Z. , Ma, J. , Zardan Gomez de la Torre, T. , Johansson, C. , Svedlindh, P. and Stromberg, M . (2016) Attomolar Zika virus oligonucleotide detection based on loop‐mediated isothermal amplification and AC susceptometry. Biosens Bioelectron, 86, 420–425. [DOI] [PubMed] [Google Scholar]
- Uddin, S.M. , Ibrahim, F. , Sayad, A.A. , Thiha, A. , Pei, K.X. , Mohktar, M.S. , Hashim, U. , Cho, J. et al (2015) A portable automatic endpoint detection system for amplicons of loop mediated isothermal amplification on microfluidic compact disk platform. Sensors 15, 5376–5389. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Walker, G.T. , Fraiser, M.S. , Schram, J.L. , Little, M.C. , Nadeau, J.G. and Malinowski, D.P. (1992) Strand displacement amplification–an isothermal, in vitro DNA amplification technique. Nucleic Acids Res 20, 1691–1696. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Wang, Q. , Zhou, Y. , Li, S. , Zhuo, C. , Xu, S. , Huang, L. , Yang, L. and Liao, K. (2013) Real‐time fluorescence loop mediated isothermal amplification for the detection of Acinetobacter baumannii . PLoS ONE 8, e66406. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Wang, X. , Li, X. , Hu, S. , Qu, H. , Zhang, Y. , Ni, H. and Wang, X. (2015a) Rapid detection of active human cytomegalovirus infection in pregnancy using loop‐mediated isothermal amplification. Mol Med Rep 12, 2269–2274. [DOI] [PubMed] [Google Scholar]
- Wang, Y. , Wang, Y. , Ma, A. , Li, D. , Luo, L. , Liu, D. , Hu, S. , Jin, D. et al (2015b) The novel multiple inner primers‐loop‐mediated isothermal amplification (MIP‐LAMP) for rapid detection and differentiation of Listeria monocytogenes . Molecules 20, 21515–21531. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Wang, X. , Yin, F. , Bi, Y. , Cheng, G. , Li, J. , Hou, L. , Li, Y. , Yang, B. et al (2016) Rapid and sensitive detection of Zika virus by reverse transcription loop‐mediated isothermal amplification. J Virol Methods 238, 86–93. [DOI] [PubMed] [Google Scholar]
- Wang, Y. , Li, H. , Wang, Y. , Zhang, L. , Xu, J. and Ye, C. (2017) Loop‐mediated isothermal amplification label‐based gold nanoparticles lateral flow biosensor for detection of Enterococcus faecalis and Staphylococcus aureus . Front Microbiol 8, 192. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Wassermann, M. , Mackenstedt, U. and Romig, T. (2014) A loop‐mediated isothermal amplification (LAMP) method for the identification of species within the Echinococcus granulosus complex. Vet Parasitol 200, 97–103. [DOI] [PubMed] [Google Scholar]
- Wastling, S.L. , Picozzi, K. , Kakembo, A.S. and Welburn, S.C. (2010) LAMP for human African trypanosomiasis: a comparative study of detection formats. PLoS Negl Trop Dis 4, e865. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Waters, R.A. , Fowler, V.L. , Armson, B. , Nelson, N. , Gloster, J. , Paton, D.J. and King, D.P. (2014) Preliminary validation of direct detection of foot‐and‐mouth disease virus within clinical samples using reverse transcription loop‐mediated isothermal amplification coupled with a simple lateral flow device for detection. PLoS ONE 9, e105630. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Watts, M.R. , James, G. , Sultana, Y. , Ginn, A.N. , Outhred, A.C. , Kong, F. , Verweij, J.J. , Iredell, J.R. et al (2014) A loop‐mediated isothermal amplification (LAMP) assay for Strongyloides stercoralis in stool that uses a visual detection method with SYTO‐82 fluorescent dye. Am J Trop Med Hyg 90, 306–311. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Wozniakowski, G. , Samorek‐Salamonowicz, E. and Kozdrun, W. (2013) Comparison of loop‐mediated isothermal amplification and PCR for the detection and differentiation of Marek's disease virus serotypes 1, 2, and 3. Avian Dis 57, 539–543. [DOI] [PubMed] [Google Scholar]
- Wu, R. , Liu, X. , Guo, B. , Chen, F. and Wang, X. (2014) Development of double loop‐mediated isothermal amplification to detect Listeria monocytogenes in food. Curr Microbiol 69, 839–845. [DOI] [PubMed] [Google Scholar]
- Xia, Y. , Guo, X.G. and Zhou, S. (2014) Rapid detection of Streptococcus pneumoniae by real‐time fluorescence loop‐mediated isothermal amplification. J Thorac Dis 6, 1193–1199. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Xia, L. , Zhang, H. , Lu, Y. , Cai, J. , Wang, B. and Jian, J. (2015) Development of a loop‐mediated isothermal amplification assay for rapid detection of Nocardia salmonicida, the causative agent of nocardiosis in fish. J Microbiol Biotechnol 25, 321–327. [DOI] [PubMed] [Google Scholar]
- Xu, C. , Feng, Y. , Chen, Y. , Gao, J. and Lu, Y. (2016) Rapid detection of measles virus using reverse transcription loop‐mediated isothermal amplification coupled with a disposable lateral flow device. Diagn Microbiol Infect Dis 85, 168–173. [DOI] [PubMed] [Google Scholar]
- Yan, G. , Jun, L. , Kangchen, Z. , Yiyue, G. , Yang, Y. , Xiaoyu, Z. , Zhiyang, S. and Lunbiao, C. (2015) Rapid and visual detection of human enterovirus coxsackievirus A16 by reverse transcription loop‐mediated isothermal amplification combined with lateral flow device. Lett Appl Microbiol 61, 531–537. [DOI] [PubMed] [Google Scholar]
- Yang, Y. , Li, Q. , Wang, S. , Chen, X. and Du, A. (2016) Rapid and sensitive detection of Babesia bovis and Babesia bigemina by loop‐mediated isothermal amplification combined with a lateral flow dipstick. Vet Parasitol 219, 71–76. [DOI] [PubMed] [Google Scholar]
- Yari, F. , Abiri, R. , Aryan, E. , Ahmadi Jouybari, T. , Navabi, J. and Alvandi, A . (2016). Loop‐mediated isothermal amplification as a fast noninvasive method of Helicobacter pylori diagnosis. J Clin Lab Anal 30, 464–470. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Ye, L. , Li, Y. , Zhao, J. , Zhang, Z. , Meng, H. , Yan, H. , Miyoshi, S.I. and Shi, L. (2015) Development of a real‐time loop‐mediated isothermal amplification assay for the sensitive and rapid detection of Listeria monocytogenes . Lett Appl Microbiol 61, 85–90. [DOI] [PubMed] [Google Scholar]
- Yin, H.Y. , Fang, T.J. and Wen, H.W. (2016) Combined multiplex loop‐mediated isothermal amplification with lateral flow assay to detect sea and seb genes of enterotoxic Staphylococcus aureus . Lett Appl Microbiol 63, 16–24. [DOI] [PubMed] [Google Scholar]
- Yongkiettrakul, S. , Jaroenram, W. , Arunrut, N. , Chareanchim, W. , Pannengpetch, S. , Suebsing, R. , Kiatpathomchai, W. , Pornthanakasem, W. et al (2014) Application of loop‐mediated isothermal amplification assay combined with lateral flow dipstick for detection of Plasmodium falciparum and Plasmodium vivax . Parasitol Int 63, 777–784. [DOI] [PubMed] [Google Scholar]
- Zanoli, L.M. and Spoto, G. (2013) Isothermal amplification methods for the detection of nucleic acids in microfluidic devices. Biosensors 3, 18–43. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Zhang, Y. , Yao, Y. , Du, W. , Wu, K. , Xu, W. , Lin, M. , Tan, H. and Li, J. (2017) Development of loop‐mediated isothermal amplification with Plasmodium falciparum unique genes for molecular diagnosis of human malaria. Pathog Glob Health 111, 247–255. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Zhao, L.M. , Li, G. , Gao, Y. , Zhu, Y.R. , Liu, J. and Zhu, X.P. (2015) Reverse transcription loop‐mediated isothermal amplification assay for detecting tomato chlorosis virus. J Virol Methods 213, 93–97. [DOI] [PubMed] [Google Scholar]
- Zhao, N. , Liu, J.X. , Li, D. and Sun, D.X. (2016) Loop‐mediated isothermal amplification for visual detection of hepatitis B virus. Zhonghua Gan Zang Bing Za Zhi 24, 406–411. [DOI] [PubMed] [Google Scholar]
- Zhao, N. , Liu, J. and Sun, D. (2017) Detection of HCV genotypes 1b and 2a by a reverse transcription loop‐mediated isothermal amplification assay. J Med Virol 89, 1048–1054. [DOI] [PubMed] [Google Scholar]
- Zhou, D. , Guo, J. , Xu, L. , Gao, S. , Lin, Q. , Wu, Q. , Wu, L. and Que, Y. (2014) Establishment and application of a loop‐mediated isothermal amplification (LAMP) system for detection of cry1Ac transgenic sugarcane. Sci Rep 4, 4912. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Ziros, P. G. , Kokkinos, P. A. , Allard, A. and Vantarakis, A . (2015) Development and evaluation of a loop‐mediated isothermal amplification assay for the detection of adenovirus 40 and 41. Food Environ Virol, 7, 276–285.x [DOI] [PubMed] [Google Scholar]
