Abstract
Data retention is a significant problem in the medical imaging domain. For example, resting-state functional magnetic resonance images (rs-fMRIs) are invaluable for studying neurodevelopment but are highly susceptible to corruption due to patient motion. The effects of patient motion can be reduced through post-acquisition techniques such as volume registration. Traditional volume registration minimizes the global differences between all volumes in the rs-fMRI sequence and a designated reference volume. We suggest using the spatiotemporal relationships between subsequent image volumes to inform the registration: they are used initialize each volume registration to reduce local differences between volumes while minimizing global differences. We apply both the traditional and novel registration methods to a set of healthy human neonatal rs-fMRIs with significant motion artifacts (N=17). Both methods impacted the mean and standard deviation of the image sequences’ correlation ratio matrices similarly; however, the novel framework was more effective in meeting gold standard motion thresholds.
Introduction
In the biomedical informatics domain, it is often difficult to recruit a large sample population to perform a prospective study. Subjects who meet the criteria for any given study are difficult to find, and even more difficult to retain. One of the best ways to lose a study participant is to ask him to return to the study site to repeat his testing.
Unfortunately, this reality is all too common, especially in the neurological imaging field. Imaging research analyzing patterns of brain activity in patients in a quiet, non-stimulated state has led to important discoveries about links between brain function and neurodevelopmental diseases such as autism and attention deficit hyperactivity disorder 1,2 . These and other studies have led to increased interest in early brain development, often through the use of neonatal resting-state functional magnetic resonance images (rs-fMRIs).
During an rs-fMRI scan, the subject lays in the scanner in a task-free resting state. Every few seconds, a new whole brain 3D image (image volume) is recorded. Each image volume contains information about the subject’s brain activity in the form of blood oxygen level dependent (BOLD) signals. The signal recorded by the MRI scanner is a combination of the BOLD signal and changes in the spin gradients. The BOLD signal indicates brain activity, but the changes in the spin gradients distort the BOLD signal in the recorded image signal. The patterns of signals between sequential volumes are analyzed to reveal various local and global neuronal networks. For example, the fMRI in Figure 1a shows neuronal networks in red and yellow activated by an auditory stimulus. However, not all fMRIs have a stimulus associated with them: in Figure 1b, the patient is in a task-free resting-state and the default mode network in green shows activation.
Figure 1.
A functional magnetic resonance image shows activity in different areas of the brain over a period of time. Images that are taken when (a) the patient is exposed to an auditory stimulus show activated networks different from the networks which are active in (b) task-free resting-state images.
This analysis depends on the assumption that the subject remained perfectly still for the entirety of the scan. Due to the spatial resolution of the rs-fMRI, the smallest movements can cause voxels to record signals from different brain regions and tissue types. Even if a movement does not significantly change the recorded position of the subject, it impacts the established magnetic spin gradients, which require approximately 8-10 seconds to realign to the magnetic field. This recovery time decreases the global signal in frames obtained during this time, causes image artifacts, and affects the functional connectivity analysis 3 . A minimum of 5-10 minutes of data unaffected by motion can be sufficient for an rs-fMRI to be used in functional connectivity studies; however, a recent study found that longer rs-fMRI sequences result in increased precision during analysis 4,5 . These findings have a significant impact on the use of neonatal rs-fMRI: it is difficult to safely prevent a neonate from moving for even five minutes, so gathering enough low-motion rs-fMRI sequences for functional connectivity analyses is a challenge.
The usability of an rs-fMRI sequence is defined in terms of changes in patient position and image signal between sequential volumes. The change of the patient’s position between subsequent frames is called the framewise displacement (FD). Several researchers have developed FD metrics; herein, we use the FD metric defined by Power et al. 3 However, FD only measures the positional effects of motion, not the effects of motion on the magnetic spin gradients: the changes in the image signal are more complex than the changes in the subject’s position. Changes in the recorded signal between neighboring frames can be measured using the temporal derivative of the variance in the image signal intensity (DVARS) 6,7 . DVARS values are a fair approximation of changes in the BOLD signal.
Efforts have been made to attempt to prevent motion from impacting rs-fMRI. Clinical protocols including education, sedation, and distraction techniques can be used to reduce a patient’s movements during acquisition, but these protocols are either not effective, not safe, or often not compatible with rs-fMRI for all populations 8-14 . Tools have been developed to measure and correct for motion in rs-fMRIs as they are acquired; but whether the motion is measured optically or via MRI signal processing, these methods do not prevent motion and cannot be used to recover motion-corrupted data in existing repositories 15-18 . The bulk of motion mitigation research focuses on the development of post-acquisition techniques.
While many different post-acquisition motion correction pipelines exist, they generally begin with a form of volume registration4,6,19-27 . The goal of volume registration is to optimize the orientation of every volume so that the differences between them and the reference volume are minimized. Unfortunately, minimizing differences between the reference volume and the other volumes in the sequence does not guarantee that the registered image sequence will have minimal differences between sequential volumes. As the usability of an rs-fMRI is defined using differences between sequential volumes, not between all volumes and the reference volume, this traditional registration framework is insufficient for its purpose.
We propose an alternative approach to volume registration which utilizes the spatiotemporal relationships between subsequent volumes to inform the registration process. We apply both the DAG-based framework and the traditional framework to a set of high-motion neonatal rs-fMRIs. We compare the performance of the two registration techniques in terms of positional similarity across the entire sequence and in terms of the FD and DVARS thresholds proposed by Power et al. and Smyser et al. 6,7 .
Methods
Subjects
Neonates were recruited as part of an ongoing prospective observational study performed at Children’s Hospital of Pittsburgh of UPMC (CHP). The study is HIPAA compliant and was approved by the Institutional Review Boards at both the University of Pittsburgh and CHP. Normal referents were recruited either from healthy pregnant volunteers or postnatally from a normal newborn nursery as part of control subjects for a longitudinal study of brain development in fetuses and neonates with congenital heart disease (CHD).
Subjects unsedated and scanned using a 3T Skyra (Siemans AG, Erlangen, Germany), using a “feed and bundle” protocol to prevent motion during the scans 28 . Newborns were fitted with earplugs (Quiet Earplugs; Sperian Hearing Protection, San Diego, CA) and neonatal ear muffs (MiniMuffs; Natus, San Carlos, CA), then positioned in the coil to minimize head tilting. An MR-compatible vital signs monitoring system (Veris, MEDRAD, Inc. Indianola, PA) was used to monitor neonatal vital signs. All scans were performed using a multi-channel head coil. The parameters for the resting-state BOLD MR scans were FOV=240 mm and TE/TR=32/2020 ms with an interplane resolution of 4x4 mm, a slice thickness of 4 mm, and a 4 mm center-to-center spacing. The acquired sequences contained 150 volumes where each volume consisted of 64x64x32 voxels.
All images underwent both volume registration techniques demonstrated in Figure 2 and were compared to Power et al.’s thresholds of acceptability for their FD and DVARS metrics 3 . According to these thresholds, a volume in a sequence is considered usable if it has an FD change of less than or equal to 0.2 mm from the previous volume and a DVARS change of less than or equal to 25 units from the previous volume on a normalized range of [0, 1000] units. Seventeen subjects’ rs-fMRIs did not meet these criteria and were used in this study.
Figure 2.
(a) Traditional volume registration may fail if the image contains too much motion, but (b) a rs-fMRI sequence can be viewed as an DAG: each node in the graph is a single frame, and position of the subject in each frame is only dependent on its position in the previous frame.
Traditional Global Registration
Traditional volume registration is the process of optimizing the alignment of every volume in a sequence to a single reference volume (Figure 2a). In our implementation, we use the first volume in each sequence as the reference volume, though other options have been used in other studies 29,30 . Then, for each volume J i in the sequence, the transformation Ø i, 0 to align J i to the reference volume J 0 is calculated. The transformations are then applied to each
volume to obtain the registered volume J i ’ :
(1) |
The registered image sequence consists of the set of registered images [J 0 , J 1 ’, J 2 ’, …, J N-1 ’] for all N images in the original sequence.
This framework only minimizes the global differences between the reference volume and the other volumes in the sequence. Large local differences between sequential volumes can occur when the registration process’s cost function falls into a local minimum. The local minima might be the best solution the registration process can find to align two volumes with large differences in the subject’s position. If the patient’s positions in many volumes of the sequence are very different from its position in the reference volume, the registration will fail to produce a sequence that minimizes both the global and local differences between volumes.
Global Registration with Local Prealignment
In our proposed framework, we treat the rs-fMRI sequence as a directed acyclic graph (DAG). A DAG consists of a set of nodes connected to each other by directed edges such that once a node has been traversed, there is no path back to it. The form of our DAG resembles a Markov chain: each volume in the sequence is represented as a node, and the relationships between sequential volumes are represented as directed edges connecting the node for volume i to that of volume i+1 . The parallel perspectives of the sequence as a set of images and of the sequence as a DAG can be seen in Figure 2b.
The cost of transitioning from one node to the next in our DAG represents the combination of the positional transformation needed to align volume i to volume i+1 and the signal change between the volumes. This representation can be written as
(2) |
where J i and J i+1 are volumes i and i+1, Ø i, i+1 is a matrix of transformation parameters that must be applied to J i to
achieve the patient’s position in J i+1, Δs i,i+1 is the matrix of changes in BOLD signal, and ϵ is the matrix of changes in the recorded signal due to the effect of motion on the spin gradients. Currently, there is no way to estimate the change in BOLD signal and the change in the recorded signal due to motion without incorporating additional information about the MRI scanner and the patient that is not included in an rs-fMRI. Instead, these parameters are treated as a single entity. We simplify our representation of the relationship between two volumes to
(3) |
Here, we use the notation ϵ∗ to represent the change in recorded signal due to BOLD changes and motion across any pair of volumes. This quantity is ignored during the registration process and can be calculated after the registration is complete.
After aligning J i and J i+i, we will use the calculated value Øi,i+1 to initialize the registration between volumes J i+1 and J i+2 :
(4) |
As in the previous equation, the quantities and ϵi+1 * are ignored during the registration process. The simplified version of Equation 4 is
(5) |
More generally,
(6) |
It is important to note that the direct transformation Ø j,k cannot be guaranteed to equal the product of the individual transformations due to the limitation of local minima in the cost function disrupting the registration process.Calculating the individual transformations Øn,n+i and multiplying them together prevents the registered image from containing large local differences between volumes while globally optimizing the alignment within the sequence.
Implementation
Both registration frameworks described in this section were implemented in Python using the nipype (Neuroimaging in Python Pipelines and Interfaces) library 31 . Affine volume registration was performed using ANTs (Advanced Normalization Tools) 32 . The metric used to estimate the dissimilarity between the pairs of volumes being registered was cross-correlation with a local window size of 5 voxels.
Experiments and Evaluations
The global volume registration techniques were applied to all 17 resting-state BOLD MR images. After the registrations, each subject had three sequences associated with it: the original sequence, the sequence registered using the traditional framework, and the sequence registered using the DAG-based framework. The registered sequences were compared to each other using their correlation ratios matrices as well as the FD and DVARS between all subsequent volumes.
The correlation ratio is an asymmetrical, spatially informed measure of the overlap between images 33 . It is calculated as:
(7) |
where x indicates the image, y indicates the voxel in image x, v xy is the value of voxel y in image x, ῡx is the average voxel value for image x, and ῡ is the average of all voxel values in both images. The correlation ratio matrix was generated by calculating the correlation ratio for every possible pair of volumes in the sequence using FLIRT (FMRIB’s Linear Image Registration Tool) 34,35 . The correlation ratio matrix was used to compare the recorded signal in each image before and after each registration technique.
The FD and DVARS metrics defined by Power et al. were calculated using the FSLMotionOutliers tool 6 . These metrics were calculated for each image and were used for evaluation of the efficacy of the registration frameworks.
Results
Image Signal in Original and Registered Images
The correlation ratio matrices for two subjects can be seen in Figure 3. These matrices are for the subject with the highest original correlation ratio mean (subject 1) and the subject with the median original correlation ratio mean (subject 8). In this figure, darker colors represent pairs of volumes with higher correlation ratios and lower similarity. For both subjects 1 and 8, the original sequence had high correlation ratios between many pairs of volumes, and those pairs of volumes have lower correlation ratios in the corrected images. The correlation ratio matrices show that both versions of both registration methods produced rs-fMRI sequences with less variability than the original images.
Figure 3.
: Correlation ratio matrices for two subjects. The three graphs for each subject show the correlation ratios between every possible volume pair in for the original sequence, the traditionally registered sequence, and the DAG registered sequence. Darker colors indicate a higher correlation ratio and lower similarity between the volumes. Both registration methods produce sequences with better inter-volume coherence than the original sequences.
The mean and standard deviation of the correlation ratios for all sequences can be seen in Figure 4. The errorbars marked with circles represent the original sequences. The errorbars marked with triangles represent the sequences registered using the traditional global registration method. The errorbars marked with squared represent the sequences registered using the DAG-based registration method. This figure shows that the original unregistered sequences generally have higher average correlation ratios and more variation across the correlation ratio matrix than the registered images for nearly all subjects.
Figure 4.
: The average and standard deviation of the correlation ratios of each sequence for each subject.
Comparison of Motion Correction Methods
The FD and DVARS values were calculated to determine how many volumes in each registered sequence met the gold standard usability thresholds. The FD and DVARS values were viewed as distribution functions representing the effects of no registration, traditional registration, and DAG-based registration. These distributions were compared using the Kolmogorov-Smirnov test, which compares the empirical distribution functions of two samples. The FD and DVARS values of all sequences were statistically significantly different at p < 2.2E − 16 . The statistics of the FD and DVARS histograms of both motion correction methods can be seen in Table 3.
Table 3.
The mean, median, standard deviation, skewness, and kurtosis of the histograms of FD and DVARS values for all image types were calculated. The histograms for the DAG-based method have lower means, medians, and standard deviations than those of the first volume correction method.
FD Values (mm) | DVARS Values (units) | |||||
---|---|---|---|---|---|---|
Statistic | No Registration | Traditional | DAG-based | No Registration | Traditional | DAG-based |
Mean | 1.07 | 2.18 | 1.22 | 63.14 | 135.15 | 97.23 |
Median | 0.3 | 1.46 | 0.56 | 35.19 | 133.48 | 77.75 |
Standard Deviation | 1.97 | 2.35 | 1.61 | 70 | 83.48 | 77.14 |
Skewness (-) | 3.86 | 3.08 | 3 | 2.76 | 1.13 | 1.55 |
Kurtosis (-) | 23.29 | 17.74 | 17.12 | 14.28 | 7.79 | 7.44 |
Power et al.’s usability thresholds were used to determine how many volumes were recovered by each framework3 . Table 4 shows the number of volumes meeting each threshold, with the traditional and DAG-based frameworks recovering 2% and 10% of volumes, respectively. These results show that the DAG-based registration technique produces sequences with lower FD and DVARS values than the traditional global registration method does.
Table 4.
The number of frames recovered by each global volume registration framework for each threshold.
Threshold | No Registration | Traditional | DAG-based |
---|---|---|---|
FD (0.2 mm) | 966 | 175 | 569 |
DVARS (25 units) | 781 | 78 | 297 |
Both | 619 | 61 | 258 |
Both (%) | 24.27 | 2.39 | 10.11 |
Discussion
Resting-state BOLD MR images are used to evaluate the functional architecture of a patient’s brain. Because resting-state BOLD images are highly susceptible to motion, the development of strong post-acquisition motion correction techniques is vital. Current pipelines for mitigating motion after sequence acquisition vary in terms of efficacy and effectiveness, but all begin with global volume registration. In this study, we compared the corrective performance of two global volume registration methods, the traditional framework and a novel DAG-based framework, on a set of 17 neonatal rs-fMRIs.
We structure our DAG model using a constraint similar to the Markov property: each frame is only connected to the immediately subsequent frame in our graph. This constraint allows the registration from the previous volume to the reference volume to be used to initialize the registration of the current volume to the reference volume. The initializations help the registration process globally and locally optimize the alignments of the image volumes to the reference volume.
The correlation ratio matrices, and FD and DVARS values were calculated for each sequence. Examination of the correlation ratio matrix statistics indicates that volume registration reduces some effects of motion in rs-fMRIs. The histograms of the FD and DVARS values of the registered sequences show that the DAG-based method was better able to correct volumes to meet Power et al’s thresholds than the traditional registration method. Overall, these results indicate that the DAG-based global registration method is better able to reduce the effects of motion in neonatal images than the traditional global registration method. While no whole sequences were recovered, many high-motion volumes within each sequence were recovered by the DAG-based registration method but not by the traditional registration method.
Motion Patterns
Upon further examination of the correlation ratio matrices, three different effects of registration were noted. These effects consist of: reduction of correlation ratio mean and standard deviation, increase in correlation ratio mean or decrease only in the correlation ratio matrix’s standard deviation, and no significant effect.
The first effect is characterized by a reduction in correlation ratio mean and standard deviation after registration. Two examples of this effect can be seen in Figure 5a. For both subjects, the initial correlation ratio matrices contain subsequences with low motion frames and subsequences with medium amounts of relatively smooth motion. The medium motion subsequences were short and scattered throughout the sequences. They are still present in the registered images’ correlation ratio matrices, though to a lesser extent.
Figure 5.
: The effects of the registration frameworks on the correlation ratios fall into 3 categories: (a) decreased correlation ratio means and standard deviations, (b) increased correlation ratio means and/or standard deviations, and (c) no significant effect.
The second effect is characterized by an increase in the mean of the correlation ratio or a decrease only in the standard deviation of the correlation ratio matrix. The patterns of motion associated with this effect are shown in Figure 5b. For both cases, the correlation ratios after registration show lower maximum correlation ratio values, but more correlation ratios in these matrices have higher values. These changes indicate that the registration frameworks may have reduced the largest motions in those sequences, but then unintentionally increased the motion in the remainder of the sequence. It is possible that removing a contiguous chunk of high motion frames from the beginning of the sequence could prevent the increase in motion from occurring during registration.
The third effect is characterized by a lack of significant change in the correlation ratio matrix mean and standard deviation. The correlation ratio matrices for the sequences that exhibited this effect can be seen in Figure 5c. The standard deviations of the correlation ratios for these matrices are small, which means that the matrices themselves appear to contain large variations. Since these large variations only encompass a relatively small range of correlation ratios, the subject likely made frequent, random, small motions rather than occasional smooth motions. This type of motion would require the application of additional motion mitigation pipelines in order to recover the sequence.
Relation to Existing Work
To the best of our knowledge, there are two other studies that use prealignment during volume registration and support our conclusions. Notably, Jenkinson et al. developed a search-based hybrid global-local optimization method that avoids local minima35 . Their method chooses the volume at the middle time frame as the reference volume and performs two sets of registrations in parallel: registration of the subsequent volumes to the reference volume and registration of the prior volumes to the reference volume. In each direction, the results of the most recent registration are used to initialize the next registration. The results of their technical analysis suggest that these prealignments more effectively reduce motion in the registered images than the traditional framework. However, this work only evaluates the impact of their registration framework on adult brain images with little motion or planned and controlled motion.
Recently, Liao et al. reported on a feasibility study of using an HMM-based framework for volume registration in 10 fetal rs-fMRIs 36 . Liao et al’s dataset consisted of 10 fetal rs-fMRIs. In each of these sequences, the fetal brain, fetal liver, and placenta were manually segmented in the first volume of the sequence as well as in five other randomly chosen volumes. The overlaps of these manual segmentations before and after registration were measured using the Dice coefficient. The Dice coefficients increased more after registration using Liao et al.’s framework than the traditional framework; however, their measure of positional change only quantifies the changes in position between the six pairs of manually segmented volumes. The 10 sequences used in this study contained approximately 300 volumes each, which suggests that a more comprehensive analysis on a larger dataset is needed to validate this approach to reducing motion in fetal images.
Our work extends both Jenkinson et al.’s and Liao et al.’s by evaluating a registration framework similar to both of theirs on a set of high-motion neonatal images, which were not studied in either of these reports. We perform a comprehensive analysis of the registered images using a pair of gold standard usability thresholds and by examining patterns of motion throughout the entire image sequence using a similarity metric.
Limitations and Future Work
Subject motion during rs-MRI scans affects both the recorded position and orientation of the subject as well as the established magnetic spin gradients within the skull. The DAG-based technique can correct the positional effects of motion, but it cannot correct the effects of the motion that disrupt the magnetic spin gradients. It is possible for this effect to be mitigated during image acquisition: methods exist for prospectively estimating subject motion and changing slice positions in each volume. Unfortunately, retrospective techniques to correct for spin gradient effects require shot-to-shot modeling of macroscopic B0 fields and are beyond the scope of the present research.
In the future, we plan to apply the DAG-based technique to other patient populations such as fetal, preadolescent, and adult populations. Then we will be able to perform an accurate comparison to Jenkinson et al. and Liao et al.’s works. We aim to generalize our registration framework to characterize the motion of different organ types, such as the fetal brain and placenta. We also plan to use our analysis process to characterize different types of motion in several populations.
Conclusions
In this feasibility study, we applied two global registration methods to set of rs-fMRIs of 17 healthy neonates. We showed that both the DAG-based and traditional registration techniques reduce the amount of motion in the images as measured using correlation ratio matrices. We then showed that the DAG-based framework is better at correcting images to a pair of established gold standard thresholds for rs-fMRI usability than the traditional framework. In the future, we plan to apply the DAG-based framework to other patient populations and multi-organ problems.
Acknowledgments
We appreciate the discussions and guidance provided by Dr. Ted Huppert and Dr. Douglas Landsittel during this study. This work was supported by the Department of Defense (W81XWH-16-1-0613), the National Heart, Lung, and Blood Institute (R01 HL128818-03), the National Institute of Neurological Disorders and Stroke (K23-063371), the National Library of Medicine (T15LM007059), the Pennsylvania Department of Health, the Mario Lemieux Foundation, and the Twenty Five Club Fund of Magee Women’s Hospital.
Figures & Table
References
- 1.Assaf M, Jagannathan K, Calhoun VD, Miller L, Stevens MC, Sahl R, et al. Neuroimage [Internet] 1. Vol. 53. Elsevier Inc.; 2010. Abnormal functional connectivity of default mode sub-networks in autism spectrum disorder patients; pp. 247–56. Available from: http://dx.doi.org/10.1016/j.neuroimage.2010.05.067. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 2.Zang YF, Yong H, Chao-Zhe Z, Qing-Jiu C, Man-Qiu S, Meng L, et al. Altered baseline brain activity in children with ADHD revealed by resting-state functional MRI. Brain Dev. 2007;29(2):83–91. doi: 10.1016/j.braindev.2006.07.002. [DOI] [PubMed] [Google Scholar]
- 3.Power JD, Mitra A, Laumann TO, Snyder AZ, Schlaggar BL, Petersen SE. Methods to detect, characterize, and remove motion artifact in resting state fMRI. Neuroimage [Internet] 2014 Jan;84:320–41. doi: 10.1016/j.neuroimage.2013.08.048. Available from: http://linkinghub.elsevier.com/retrieve/pii/S1053811913009117. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 4.van Dijk KRA, Sabuncu MR, Buckner RL. Neuroimage [Internet] 1. Vol. 59. Elsevier Inc.; 2012. The influence of head motion on intrinsic functional connectivity MRI; pp. 431–8. Available from: http://dx.doi.org/10.1016/j.neuroimage.2011.07.044. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 5.Laumann TO, Gordon EM, Adeyemo B, Snyder AZ, Joo SJ, Chen M-Y, et al. Functional System and Areal Organization of a Highly Sampled Individual Human Brain. Neuron [Internet] 2015 Aug;87(3):657–70. doi: 10.1016/j.neuron.2015.06.037. Available from: https://linkinghub.elsevier.com/retrieve/pii/S0896627315006005. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 6.Power JD, Barnes KA, Synder AZ, Schlagger BL, Petersen SE. Spurious but systematic correlations in functional connectivity MRI networks arise from subject motion. Neuroimage. 2012;59(3):2142–54. doi: 10.1016/j.neuroimage.2011.10.018. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 7.Smyser CD, Neil JJ. Semin Perinatol [Internet] 2. Vol. 39. Elsevier; 2015. Use of resting-state functional MRI to study brain development and injury in neonates; pp. 130–40. Available from: http://dx.doi.org/10.1053/j.semperi.2015.01.006. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 8.Alexander M. Managing Patient Stress in Pediatric Radiology. Radiologic Technology. 2012;83(6):549–560. [PubMed] [Google Scholar]
- 9.Barnea-Goraly N, Weinzimer SA, Ruedy KJ, Mauras N, Beck RW, Marzelli MJ, et al. High success rates of sedation-free brain MRI scanning in young children using simple subject preparation protocols with and without a commercial mock scanner - the Diabetes Research in Children Network (DirecNet) experience. Pediatr Radiol [Internet] 2014 Feb 6;44(2):181–6. doi: 10.1007/s00247-013-2798-7. Available from: http://www.ncbi.nlm.nih.gov/pmc/articles/PMC3946760/ [DOI] [PMC free article] [PubMed] [Google Scholar]
- 10.Coté CJ, Wilson S. Guidelines for Monitoring and Management of Pediatric Patients Before, During, and After Sedation for Diagnostic and Therapeutic Procedures: Update 2016. Pediatrics [Internet] 2016 doi: 10.1542/peds.2016-1212. Jun 27; Available from: http://pediatrics.aappublications.org/content/early/2016/06/24/peds.2016-1212.abstract. [DOI] [PubMed] [Google Scholar]
- 11.Gale C, Jeffries S, Logan KM, Chappell KE, Uthaya SN, Modi N. Avoiding sedation in research MRI and spectroscopy in infants: our approach, success rate and prevalence of incidental finding. Arch Dis Child Fetal Neonatal Ed. 2013;98:F267–8. doi: 10.1136/archdischild-2012-302536. [DOI] [PubMed] [Google Scholar]
- 12.Harned RK, Strain JD. MRI-compatible audio / visual system: impact on pediatric sedation. Pediatr Radiol. 2001;31:247–50. doi: 10.1007/s002470100426. [DOI] [PubMed] [Google Scholar]
- 13.Khan JJ, Donnely LF, Koch BL, Curtwright LA, Dickerson JM, Hardin JL, et al. A program to decrease the need for pediatric sedation for CT and MRI. Appl Radiol. 2007 April:30–3. [Google Scholar]
- 14.Garcia-Palacios A, Hoffman HG, Richards TR, Seibel EJ, Sharar SR. Use of Virtual Reality Distraction to Reduce Claustrophobia Symptoms during a Mock Magnetic Resonance Imaging Brain Scan: A Case Report. CyberPsychology Behav. 2007;10(3):485–8. doi: 10.1089/cpb.2006.9926. [DOI] [PubMed] [Google Scholar]
- 15.Dosenbach NUF, Koller JM, Earl EA, Miranda-Dominguez O, Klein RL, Van AN, et al. Neuroimage. January. Vol. 161. Elsevier Ltd; 2017. Real-time motion analytics during brain MRI improve data quality and reduce costs; pp. 80–93. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 16.Zaitsev M, Burak A, LeVan P, Knowles BR. Prospective Motion Correction in Functional MRI. Neuroimage. 2017:33–42. doi: 10.1016/j.neuroimage.2016.11.014. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 17.Aksoy M, Newbould R, Straka M, Holdsworth SJ, Skare ST, Santos JM, et al. A Real Time Optical Motion Correction System Using a Single Camera and 2D Marker. Proc 16th Sci Meet ISMRM. 2008;16:3120. [Google Scholar]
- 18.Zaitsev M, Dold C, Sakas G, Hennig J, Speck O. Magnetic resonance imaging of freely moving objects: prospective real-time motion correction using an external optical motion tracking system. Neuroimage. 2006;31(3):1038–50. doi: 10.1016/j.neuroimage.2006.01.039. [DOI] [PubMed] [Google Scholar]
- 19.Behzadi Y, Restom K, Liau J, Liu TT. A. component based noise correction method (CompCor) for BOLD and perfusion based fMRI. Neuroimage. 2007;37(1):90–101. doi: 10.1016/j.neuroimage.2007.04.042. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 20.Jo HJ, Saad ZS, Simmons WK, Milbury LA, Cox RW. Neuroimage [Internet] 2. Vol. 52. Elsevier B.V.; 2010. Mapping sources of correlation in resting state FMRI, with artifact detection and removal; pp. 571–82. Available from: http://dx.doi.org/10.1016/j.neuroimage.2010.04.246. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 21.Parkes L, Fulcher BD, Yucel M, Fornito A. An evaluation of the efficacy, reliability, and sensitivity of motion correction strategies for resting-state functional MRI. bioRxiv. 2017 doi: 10.1016/j.neuroimage.2017.12.073. [DOI] [PubMed] [Google Scholar]
- 22.Patel AX, Kundu P, Rubinov M, Jones PS, Vértes PE, Ersche KD, et al. Neuroimage [Internet] Vol. 95. Elsevier B.V.; 2014. A wavelet method for modeling and despiking motion artifacts from resting-state fMRI time series; pp. 287–304. Available from: http://dx.doi.org/10.1016/j.neuroimage.2014.03.012. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 23.Patriat R, Reynolds RC, Birn RM. Neuroimage. Vol. 144. Elsevier; 2017. An improved model of motion-related signal changes in fMRI; pp. 74–82. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 24.Pruim RHR, Mennes M, van Rooij D, Llera A, Buitelaar JK, Beckmann CF. Neuroimage [Internet] Vol. 112. Elsevier Inc.; 2015. ICA-AROMA: A robust ICA-based strategy for removing motion artifacts from fMRI data; pp. 267–77. Available from: http://dx.doi.org/10.1016/j.neuroimage.2015.02.064. [DOI] [PubMed] [Google Scholar]
- 25.Satterthwaite TD, Wolf DH, Loughead J, Ruparel K, Elliott MA, Hakonarson H, et al. Impact of In-Scanner Head Motion on Multiple Measures of Functional Connectivity: Relevance for Studies of Neurodevelopment in Youth. Neuroimage. 2012;60(1):623–32. doi: 10.1016/j.neuroimage.2011.12.063. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 26.Salimi-Khorshidi G, Douaud G, Beckmann CF, Glasser MF, Griffanti L, Smith SM. Neuroimage [Internet] Vol. 90. Elsevier B.V.; 2014. Automatic denoising of functional MRI data: Combining independent component analysis and hierarchical fusion of classifiers; pp. 449–68. Available from: http://dx.doi.org/10.1016/j.neuroimage.2013.11.046. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 27.Yan CG, Cheung B, Kelly C, Colcombe S, Craddock RC, Di Martino A, et al. Neuroimage [Internet] Vol. 76. Elsevier Inc.; 2013. A comprehensive assessment of regional variation in the impact of head micromovements on functional connectomics; pp. 183–201. Available from: http://dx.doi.org/10.1016/j.neuroimage.2013.03.004. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 28.Windram JD, Grosse-Wortmann L, Shariat M, Greer M-L, Yoo S-J. J Cardiovasc Magn Reson [Internet] Suppl 1. Vol. 13. BioMed Central Ltd; 2011. The Feed and Sleep method: how to perform a cardiac MRI in the 1st year of life without the need for General Anesthesia; p. P224. Available from: http://jcmr-online.com/content/13/S1/P224. [Google Scholar]
- 29.Friston KJ, Williams S, Howard R, Frackowiak RSJ, Turner R. Movement-Related effects in fMRI time-series. Magn Reson Med [Internet] 1996;35(3):346–55. doi: 10.1002/mrm.1910350312. Available from: http://doi.wiley.com/10.1002/mrm.1910350312. [DOI] [PubMed] [Google Scholar]
- 30.Liao R, Krolik JL, McKeown MJ. An information-theoretic criterion for intrasubject alignment of FMRI time series: Motion corrected independent component analysis. IEEE Trans Med Imaging. 2005;24(1):29–44. doi: 10.1109/tmi.2004.837791. [DOI] [PubMed] [Google Scholar]
- 31.Gorgolewski K, Burns CD, Madison C, Clark D, Halchenko YO, Waskom ML, et al. Nipype : a flexible, lightweight and extensible neuroimaging data processing framework in Python. Front Neuroinform. 2011;5(August) doi: 10.3389/fninf.2011.00013. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 32.Avants BB, Tustison NJ, Stauffer M, Song G, Wu B, Gee JC. The Insight ToolKit image registration framework. Front Neuroinform. 2014;8(April) doi: 10.3389/fninf.2014.00044. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 33.Roche A, Malandain G, Pennec X, Ayache N. The correlation ratio as a new similarity measure for multimodal image registration. In: Wells WM, Colchester A, Delp S, editors. Proc. MICCAI [Internet] Berlin, Heidelberg: Springer Berlin Heidelberg; 1998. pp. 1115–24. Available from: https://doi.org/10.1007/BFb0056301. [Google Scholar]
- 34.Jenkinson M, Smith S. A global optimisation method for robust affine registration of brain images. Med Image Anal. 2001;5:143–56. doi: 10.1016/s1361-8415(01)00036-6. [DOI] [PubMed] [Google Scholar]
- 35.Jenkinson M, Bannister P, Brady M, Smith S. Improved Optimization for the Robust and Accurate Linear Registration and Motion Correction of Brain Images. Neuroimage. 2002;17:825–41. doi: 10.1016/s1053-8119(02)91132-8. [DOI] [PubMed] [Google Scholar]
- 36.Liao R, Turk EA, Zhang M, Luo J, Ellen Grant P, Adalsteinsson E, et al. Temporal registration in in-utero volumetric MRI time series. Lect Notes Comput Sci (including Subser Lect Notes Artif Intell Lect Notes Bioinformatics) [Internet] 2016;9902 LNCS:54–62. doi: 10.1007/978-3-319-46726-9_7. Available from: http://arxiv.org/abs/1608.03907. [DOI] [PMC free article] [PubMed] [Google Scholar]