Abstract
Cardiac imaging has a pivotal role in the prevention, diagnosis and treatment of ischaemic heart disease. SPECT is most commonly used for clinical myocardial perfusion imaging, whereas PET is the clinical reference standard for the quantification of myocardial perfusion. MRI does not involve exposure to ionizing radiation, similar to echocardiography, which can be performed at the bedside. CT perfusion imaging is not frequently used but CT offers coronary angiography data, and invasive catheter-based methods can measure coronary flow and pressure. Technical improvements to the quantification of pathophysiological parameters of myocardial ischaemia can be achieved. Clinical consensus recommendations on the appropriateness of each technique were derived following a European quantitative cardiac imaging meeting and using a real-time Delphi process. SPECT using new detectors allows the quantification of myocardial blood flow and is now also suited to patients with a high BMI. PET is well suited to patients with multivessel disease to confirm or exclude balanced ischaemia. MRI allows the evaluation of patients with complex disease who would benefit from imaging of function and fibrosis in addition to perfusion. Echocardiography remains the preferred technique for assessing ischaemia in bedside situations, whereas CT has the greatest value for combined quantification of stenosis and characterization of atherosclerosis in relation to myocardial ischaemia. In patients with a high probability of needing invasive treatment, invasive coronary flow and pressure measurement is well suited to guide treatment decisions. In this Consensus Statement, we summarize the strengths and weaknesses as well as the future technological potential of each imaging modality.
Subject terms: Ischaemia, Magnetic resonance imaging, Computed tomography, Positron-emission tomography, Echocardiography, Radionuclide imaging
Cardiac imaging has a pivotal role in the prevention, diagnosis and treatment of ischaemic heart disease. In this Consensus Statement, the authors summarize the use of SPECT, PET, MRI, echocardiography, CT and invasive coronary flow and pressure measurement, and describe the relative strengths and weaknesses of each modality.
Introduction
International guidelines advocate noninvasive testing for patients with suspected ischaemia before proceeding with revascularization decision-making1–4. Noninvasive clinical cardiac imaging continues to undergo rapid evolution, focusing on quantitative perfusion technologies for the assessment of myocardial ischaemia and coronary flow. At present, imaging of myocardial ischaemia stands at a crossroads. During a European meeting on quantitative cardiac imaging, a bench-to-bedside-to-bench perspective was used to summarize the current status and future potential of myocardial ischaemia imaging from the viewpoint of basic scientists and clinical researchers. This approach created discussions, which led to this Consensus Statement on the main advantages and disadvantages of each imaging modality, a clinical consensus on the appropriateness for specific indications and a summary of the latest developments, which together provide a framework for future quantitative imaging of myocardial ischaemia.
Pathophysiology considerations
The coronary circulation comprises the epicardial conductance vessels (diameter 1–6 mm) feeding an extensive network of small vessels (diameter <300–400 μm) that penetrates the cardiac muscle tissue and is the site of regulation of myocardial blood flow (MBF; Fig. 1a,b). High-resolution 3D fluorescence cryomicrotome imaging5 has also revealed the existence of abundant small collateral vessels both between (intercoronary) and within (intracoronary) perfusion territories of major coronary arteries6,7. Importantly, blood supply via well-developed collaterals can reduce the area of myocardium at risk of ischaemia, which can be detected by all myocardial perfusion imaging techniques8–10. From a physiological perspective, microvascular resistance is closely adjusted at rest via integrated control mechanisms to maintain blood supply commensurate with cardiac workload and to compensate for pressure loss induced by an epicardial stenosis (autoregulation)11–13 (Fig. 1c). When microvascular resistance is minimized by potent vasodilators, such as adenosine, coronary flow becomes primarily dependent on perfusion pressure. Given that vessels without tone behave as elastic conduits, their diameters become pressure-dependent, and the minimized coronary resistance (at maximal vasodilatation; Fig. 1c) increases with decreasing perfusion pressure14–16. Regional myocardial perfusion in normal tissue is highly heterogeneous, attributable to vascular (asymmetric branching) and metabolic (O2 consumption) heterogeneity17,18. Transmural perfusion gradients and the microcirculation itself are further influenced by cardiac–coronary interaction with or without an epicardial obstruction. Compressive forces exerted by cardiac contraction render the subendocardium particularly vulnerable to ischaemia, especially at elevated heart rate or at low perfusion pressure distal to a stenosis19–21. The effects of epicardial obstruction, therefore, extend beyond the stenosis into the microcirculation22. The fundamental parameters for the assessment of myocardial ischaemia are regional absolute MBF (in units of millilitres per minute per gram of tissue) and relative perfusion, as well as relative parameters, such as myocardial perfusion reserve (MPR), which is the ratio of MBF under exercise-induced or pharmacologically induced stress to MBF at rest22.
Ischaemia imaging modalities
The potential of noninvasive assessment of blood flow in the coronary microcirculation as a gatekeeper for invasive coronary angiography is the subject of a growing research effort. Important new insights have emerged regarding the clinical implications of the quantitative and qualitative assessment of myocardial ischaemia using the different myocardial perfusion imaging modalities, such as SPECT, PET, MRI, echocardiography and cardiac CT. In addition to summarizing the current clinical application of qualitative and quantitative ischaemia imaging, we also discuss the emerging possible use of artificial intelligence with deep learning for the detection and characterization of disease.
The unifying principle of all noninvasive techniques is that a contrast agent is injected into a peripheral vein. The contrast agent is transported to the heart and acts like a test substance (tracer) for blood and its transport through tissues. If the myocardium is normally perfused, the contrast agent is transported to the myocardium and can be detected with the use of noninvasive imaging modalities. If ischaemia is present, less contrast agent reaches the affected region and/or its wash-in or wash-out is delayed. This process is typically registered by a dynamic series of images that are sensitive to the specific contrast agent used.
Subsequent tracer kinetic modelling16 gives quantitative values of MBF and/or MPR. For this type of analysis, we need to know the time course of the contrast agent or tracer in the blood over time, that is, the arterial input function (AIF). The AIF is typically assessed either from the left ventricular cavity or by arterial blood sampling. From these principles, the AIF clearly accounts for variations in left ventricular function. However, collaterals cannot be accounted for and might introduce delayed wash-in23 and, on the basis of the mechanisms shown in Fig. 1d,e, might introduce systematic errors in the quantitative MBF or MPR values. Therefore, unlike catheter-based assessment and CT-based estimation of epicardial fractional flow reserve (FFR), the noninvasive ischaemia imaging techniques directly measure MBF and MPR, or at least provide a semiquantitative estimate. Some of these techniques allow the additional assessment of parameters beyond MBF and MPR and are used in further analysis by modern methods, such as machine and/or deep learning24–27. The common goal is to guide patient management and to provide the requisite justification for invasive coronary angiography and intracoronary haemodynamic measurements. Importantly, no single imaging technology can currently provide all measures of coronary circulation, and all imaging techniques have specific advantages and disadvantages while also providing different assessments of the coronary vascular components using anatomical or functional imaging (Table 1).
Table 1.
Parameter | SPECT | PET | MRI | Echocardiography | CT | Invasive coronary flow and pressure measurement |
---|---|---|---|---|---|---|
General | ||||||
Ionizing radiation use | Yes (radiopharmaceutical) | Yes (radiopharmaceutical) | No | No | Yes (X-rays) | Yes (X-rays) |
Stressor | Exercise or vasodilator agents | Exercise or vasodilator agents | Mainly vasodilator agents | Exercise or vasodilator agents | Mainly vasodilator agents | Vasodilator agents |
Contrast agent or tracer | 99mTc-sestamibi or 99mTc-tetrofosmin | 15O, 82Rb, 13NH3 or 18F-flurpiridaz | Gadolinium-based | Microbubbles | Iodine-based | None |
Contrast agent or tracer distribution | Intracellular | Freely diffusible: intravascular, extracellular and intracellular | Intravascular and extracellular | Intravascular | Intravascular and extracellular | NA |
Type of measurement | Static; dynamic feasible with new cameras | Dynamic bolus or static | Dynamic bolus | Clearance–reperfusion | Dynamic bolus or static | Pressure and/or flow velocity |
Linear relationship between blood flow and tracer | No (underestimation at high flow) | Yes | No | Yes | No | NA |
Linear relationship between tracer and image signal | Yes (radiopharmaceutical) | Yes | No | Yes | Yes | NA |
Contrast-to-noise ratio | High | Low | High | High | Low | NA |
Temporal resolution (acquisition time per frame) | 10 s | 1–5 s | Approximately 100–200 ms | Approximately 4–50 ms (20–250 frames per s) | Approximately 150–200 ms | NA |
Spatial resolution (image analysis voxel size) | 10 × 10 × 10 mm³ | 4 × 4 × 4 mm³ | 1 × 2 × 6–8 mm³ | 1 × 1–3 × 3–6 mm³ (spatially varying) | 0.5 × 0.5 × 6–8 mm³ | NA |
Isotropic left ventricle coverage | Yes | Yes | No | No | Yes | NA |
Technical challenges | ||||||
Stenosis quantification | NA | NA | Spatial resolution | NA | Beam hardening | Variability and projections |
Coronary haemodynamic assessment | NA | NA | Spatial resolution | NA | Flow assumptions | Costs and availability |
Ischaemia quantification | Spatial and temporal resolution | Spatial and temporal resolution | Contrast agent signal nonlinearity | Intravascular contrast agent | Contrast agent dynamics, noise and dose | NA |
Types of coronary vascular component assessment by each imaging modality | ||||||
Epicardial conductance vessel (>500 μm) | Functional assessment | Functional assessment | Functional assessment | Functional assessment | Anatomical and functional assessment | Anatomical and functional assessment |
Resistance vessels and arterioles (<500 μm) | Functional assessment | Functional assessment | Functional assessment | Functional assessment | Functional assessment | NA |
Capillaries | Functional assessment | Functional assessment | Functional assessment | Functional assessment | Functional assessment | NA |
Endocardial–epicardial flow ratio | NA | NA | Yes | NA | Yes | NA |
Collaterals | Yes (but with limitations) | Yes | Yes | Yes | Yes | Yes |
Contraction–flow relationship | NA | NA | Yes | Yes | Yes | Yes |
Advantages and disadvantages | ||||||
Advantages | Wide availability and quantification now also possible in patients with a high BMI | Technically best-suited test for ischaemia quantification; novel tracers and small cyclotrons have become available | Assessment of function, perfusion and viability without ionizing radiation | Availability at the bedside for analysis without ionizing radiation | Quantitative scale and high spatial resolution for coronary stenosis and plaque analysis | Immediate treatment opportunity during the same procedure |
Disadvantages | Low image quality owing to attenuation | Limited availability (available in specialized centres only) | Limited coronary stenosis analysis and quantification challenges | No coronary artery stenosis analysis and quantification challenges | Radiation dose, low contrast-to-noise ratio and quantification challenges | Limited use in patients without acute presentation |
Consensus ratings were performed using a Delphi process with ratings by 20 investigators (six cardiologists, four radiologists, one dual cardiologist–radiologist, one nuclear medicine physician and eight methodologists). NA, not applicable.
Technical characteristics and challenges
Major practical challenges for the assessment of myocardial ischaemia using the methods under consideration include the following:
SPECT: radiation dose, spatial resolution and limited quantification of myocardial perfusion28.
PET: lower spatial resolution of quantitative 15O-water PET than with myocardial CT or MRI perfusion imaging and limited visual assessment29,30.
MRI: increased prevalence of pacemakers31 and limited spatial coverage of the left ventricle32.
Echocardiography: common presence of noise and artefacts, lack of reproducibility, variable image quality and time-consuming manual analysis33.
CT: limited temporal resolution, presence of beam and scatter artefacts, radiation dose, and low contrast-to-noise ratios34–37.
Invasive FFR: diagnostic and prognostic characteristics, complexity of the procedure and its limited uptake in clinical practice38,39.
From technical and pathophysiological perspectives, numerous aspects need to be considered for the quantification of myocardial ischaemia. The tracer distribution characteristics vary widely between imaging techniques. MRI and CT tracers enter the extravascular extracellular space (interstitial space); nuclear tracers can also enter the intracellular space or even bind within the myocyte (most SPECT and PET tracers, except 15O-water) (Table 1). By contrast, microbubbles used for echocardiography remain in the intravascular space. On the basis of the different tracer characteristics, the agreement between the numerical results obtained with the different techniques varies40–42. Even microspheres, which are the experimental gold standard of perfusion, can distribute in a heterogeneous manner when the analysed region becomes small, possibly reflecting technical limitations and/or physiological variations in regional flow43. A nonlinear relationship exists between MBF and tracer uptake in SPECT and most PET tracers except 15O-water. Both MRI and CT use contrast agents that extravasate from the intravascular to the extravascular space in a fashion that is nonlinearly dependent on blood flow44. In addition, obtaining a linear relationship between MRI tracer concentration and signal intensity is difficult because of the complexity of MRI contrast mechanisms45,46. Accurately measuring the AIF is challenging with SPECT47, PET48, MRI49,50 and CT51 (Fig. 1c,d), which can result in biased measurements of MBF (Fig. 1e). Tracer kinetic modelling of MBF needs to account for these differences between modalities.
Methods of consensus
The emerging imaging concepts and their challenges matter not only to cardiologists, radiologists and nuclear medicine physicians but also to non-specialists. As the field has become very complex, it deserves a comprehensive and up-to-date expert consensus. Experts in the cardiac imaging modalities from seven European countries, with a balance of clinical disciplines (cardiology, nuclear medicine and radiology) and basic scientists, were involved in the Quantitative Cardiac Imaging meeting. This Consensus Statement is not, therefore, endorsed by a single specialist society, but is driven by scientists from all disciplines collaborating to provide a multidisciplinary consensus. The content and recommendations in this article emerged from discussions among our diverse team, which aimed to overcome political and professional interests to produce balanced consensus recommendations. In a subsequent real-time Delphi process, the technical parameters of each modality were summarized by consensus (Table 1).
All the authors participated in the Delphi process and judged all imaging modalities, to result in a consensus across modalities. The consensus process was performed after all lectures were given and discussed during the Quantitative Cardiac Imaging meeting and was organized into technical and clinical consensus processes. During the technical consensus process (Table 1), a total of 20 authors participated (six cardiologists: K.F.K., A.C., P.K., R.S., J.J.P. and T.v.d.H.; four radiologists: M.D., K.N., R.M. and F.M.; one dual cardiologist–radiologist: P.M.-H; one nuclear medicine physician: F.B.; and eight methodologists: M.S., M.K., S.K., T.S., S.N., M.L., J.M. and L.S.). Technical assessments by every participant for all items were made transparent to all participants to allow real-time evaluation and reconsideration of his or her own judgements for the Delphi consensus process.
For the clinical consensus process (Fig. 2), a total of 16 authors participated and were divided into a development team and a clinical appropriateness team. The development team consisted of eight investigators (one dual cardiologist–radiologist: P.M.-H.; two radiologists: K.N. and F.M.; and five methodologists: M.S., T.S., A.K., J.M. and L.S.), who did not participate in the clinical appropriateness rating but defined the questions and categories used in the clinical consensus. The clinical appropriateness team consisted of eight investigators providing clinical consensus ratings for all methods and all clinical scenarios (four cardiologists: K.F.K., A.C., R.S. and J.J.P.; two radiologists: M.D. and R.M.; one nuclear medicine physician: F.B.; and one methodologist: M.L.). Judgements from each team member were fully taken into consideration, displayed in a transparent fashion during the real-time Delphi process and averaged at the end of the assessment to produce final appropriateness ratings (ranging from 1 to 9) for all imaging tests in all clinical settings.
Moreover, in this Consensus Statement, we avoided giving the final verdict on a ‘competition between the methods’, but instead presented the potential relative merits of the methods that are currently available. Differences of opinion will always exist, which cannot entirely be avoided, but our cross-disciplinary Delphi process represents a solid approach to the clinical question. This Delphi process helped to define appropriate clinical indications as well as some of the directions for future technical developments to overcome challenges of SPECT, PET, MRI, echocardiography, CT and invasive coronary flow and pressure measurements. This Consensus Statement also describes major trends and breakthroughs relevant to patients with cardiac disease for all six imaging modalities in the sections below. Although we attempt to give a balanced overview of all the available imaging modalities using the Delphi consensus process, region-specific or institution-specific availability or expertise might increase or decrease the relative utility of a particular modality.
SPECT
Role in assessment of ischaemic heart disease
SPECT has been the centrepiece of clinical cardiovascular imaging for decades. SPECT-based evaluation of the extent of myocardial ischaemia as a percentage of the left ventricular myocardium, together with concomitantly measured left ventricular function and volumes, is well established for the diagnosis of myocardial ischaemia1. SPECT not only has incremental prognostic value over clinical assessment alone but is also important in guiding therapy. The current clinical paradigm that the degree of ischaemia defines the individual risk, which in turn should be used for risk-based decision-making on revascularization or optimized medical therapy, is based on large registries of SPECT perfusion imaging52. Of note, no studies have compared outcomes when therapy is decided on the basis of SPECT versus an alternative test. As SPECT measures any perfusion to the myocyte with a tracer that is bound in the mitochondria, and owing to the temporal resolution, a distinction between primary-vessel and collateral flow cannot be made.
Quantitative assessment of pathophysiology
Detailed technical characteristics of SPECT are listed in Table 1. Technical evolution has occurred, with the aim of maximizing sensitivity to reduce both the amount of injected radiopharmaceuticals and the acquisition time. These advances have been paralleled by a shift towards increased BMI in the patient population. Solid-state detector technology based on cadmium–zinc–telluride (CZT) has been central to the technical advances in SPECT imaging. Small semiconductor detectors allow fully digital acquisition schemes and obviate the need for heavy sodium iodide crystals and large photomultipliers, thereby enabling compact camera designs (Fig. 3a). The high sensitivity (84%) of recent CZT SPECT systems and a specificity of 69% to detect obstructive coronary artery disease53 has enabled dynamic imaging to assess the kinetics of perfusion tracers in blood and the myocardium. This information allows compartmental modelling to delineate absolute MBF and coronary flow reserve (CFR) by SPECT. Recent work has shown the feasibility of MBF quantification with CZT SPECT and has provided validation against the microsphere gold standard in an experimental model54 and in humans55 compared with PET. Clinically implementing this approach with SPECT protocols has the potential to provide incremental diagnostic and prognostic value for ischaemia assessment over the previous standard of relative regional perfusion defect measurement56,57, because it can detect conditions that affect the entire myocardium, such as severe ischaemia in multivessel disease or microvascular dysfunction (mostly in the subendocardium), with the caveat of the limited spatial resolution of SPECT. Therefore, integrating measures of transient post-ischaemic dilatation further improves the diagnostic accuracy and can be calculated in a highly automated fashion58.
Indications and clinical applications
SPECT is most commonly applied for myocardial perfusion imaging. Clinical indications for SPECT are listed in detail in Fig. 2. Major advantages of dedicated cardiac SPECT cameras include superior sensitivity and resolution while allowing radiation dose reduction across a range of patient conditions, as well as allowing the imaging of patients with challenging features, such as a high BMI59,60. Compared with regular SPECT, CZT systems increase the effective sensitivity by fourfold to tenfold, and also provide higher spatial and energy resolution59,60. Accordingly, high-quality images are obtained with shorter acquisition times and/or a smaller injected dose of the radiopharmaceutical, which is beneficial for various groups of patients with complicated disease. Several multicentre studies support the usefulness as well as the diagnostic and prognostic value of CZT-based myocardial perfusion SPECT28. Although early work with these novel systems focused on the reduction in imaging time from 15–30 min with standard SPECT down to 2–3 min with CZT SPECT using a standard amount of injected radioactivity61,62, the aim of subsequent work was to reduce the amount of injected radioactivity to minimize patient exposure to ionizing radiation. A recent multicentre trial suggests that CZT imaging can be completed with an effective dose of 1 mSv at an image quality that is still superior to that obtained with standard SPECT63.
Future developments
Commercially available software tools for SPECT analysis can be readily implemented on every acquisition system, allowing reproducible measurement of perfusion defect sizes and ventricular function (Fig. 3b). These tools also enable registration and fusion of SPECT datasets with coronary CT angiography for improved prediction of long-term outcomes64 (Fig. 3c) and the latest developments provide options for the absolute quantification of MBF from dynamic datasets (Fig. 3d) and the integration of artificial intelligence techniques24,65. Future work will define how this comprehensive toolbox of quantitative parameters is best utilized in the work-up of myocardial ischaemia for guidance of targeted coronary interventions of the correct coronary artery, for the selection of coronary artery bypass grafting versus stenting versus optimal medical therapy alone, and for serial monitoring of the effects of therapy.
In summary, cardiac SPECT has advanced through the adoption of solid-state detector-equipped dedicated cameras as the new standard. This implementation enables fast assessment of myocardial perfusion and function with exposure to a low dose of radiation, and includes diagnostic and prognostic measures of relative regional ischaemia that are well established and quantitative. The next phase will include the quantification of MBF and CFR. The techniques are readily adopted from PET as the reference standard and can be translated to the field of SPECT owing to the increased sensitivity and the improved temporal resolution of the new cardiac camera systems. On the basis of its characteristics, SPECT is the primary clinical method for the assessment of myocardial ischaemia, and the latest technological advances now also allow robust imaging of patients with challenging features, such as those with a high BMI.
Key points for SPECT
SPECT is most commonly used in the clinic for myocardial perfusion imaging.
Challenges of SPECT include radiation dose and limited quantification of myocardial perfusion28.
Dedicated cardiac SPECT cameras have emerged, with improved sensitivity and resolution at lower radiation doses and in patients with challenging features (including those with a high BMI)59,60.
Quantitative measures of the perfusion defect size have become more widely available as diagnostic and prognostic markers with the introduction of solid-state detector CZT technology.
Dynamic imaging enables compartmental modelling and provides absolute measures of myocardial ischaemia, thereby bringing SPECT closer to PET as the reference standard.
PET
Role in assessment of ischaemic heart disease
PET is an inherently quantitative imaging technique that allows the accurate measurement of radioactivity concentrations in vivo, making PET the primary test for patients with multivessel disease to confirm or exclude balanced ischaemia. Currently, four different PET tracers are used clinically for the assessment of MBF: 82Rb, 13N-ammonia, 15O-water and 18F-flurpiridaz66. On the basis of close to 100% extraction, 15O-water PET is considered the clinical gold standard for perfusion quantification given that the image signal is directly proportional to tracer concentration, and tracer kinetic modelling is well established. All other tracers show a varying decrease in extraction with increasing flow, requiring correction to derive MBF (Fig. 4a). Because of their short half-lives, 82Rb and 15O-water allow the completion of rest–stress protocols within 30 min, with a total radiation dose that is lower than that of SPECT, although new SPECT technologies considerably reduce the radiation dose, as described above.
Quantitative assessment of pathophysiology
Detailed technical characteristics of PET are listed in Table 1. Because 15O-water is freely diffusible, no simple static uptake PET images are available for visual assessment, and images of perfusion defects are sometimes grainy and difficult to interpret. Therefore, quantification is needed for clinical assessment using 15O. With 82Rb, 13N-ammonia and 18F-flurpiridaz, perfusion defects are visualized in a similar way to SPECT, but absolute MBF measurements can be provided using tracer kinetic modelling and correction for limited extraction. However, absolute measures remain variable, and a lack of standardization exists between systems. The complexity of quantitative data analysis has long hampered the clinical feasibility of 15O-water PET. However, advances in scanner technology, image reconstruction methods and data analysis during the past decade have enabled nearly automated and fast computation of parametric images showing MBF at the voxel level and have facilitated the use of 15O-water in the clinical setting29,30. Another disadvantage of the lack of uptake images using 15O-water is that myocardial function and volumes cannot easily be quantified. Estimating ejection fractions from gated first-pass images has been shown to correlate well with values derived from MRI30,67. An advantage of the free diffusibility of 15O-water is that it allows the calculation of the perfusable tissue fraction, which is the ratio between uptake and clearance rate constants. Normalizing this parameter for the anatomical tissue fraction gives the perfusable tissue index, which is a marker of myocardial viability68,69. Therefore, MBF, viability and functional parameters can now be determined from a single 15O-water PET scan (Fig. 4b).
Indications and clinical applications
Myocardial perfusion PET is increasingly being used for the evaluation of patients with known or suspected myocardial ischaemia. Clinical indications for PET are listed in detail in Fig. 2. The vast majority of studies have been conducted with static uptake images of 82Rb and 13N-ammonia. In a pooled analysis of these studies, weighted sensitivity, specificity, negative predictive value and positive predictive value were 91%, 86%, 81% and 93%, respectively70. However, almost all these studies compared PET with invasive coronary angiography without invasive coronary flow or pressure measurement71. For such indirect detection of obstructive epicardial stenosis, PET is as accurate as CT or MRI perfusion imaging72,73. In addition, mounting evidence indicates that quantitative analysis of PET is superior to static-uptake image grading74–76. Even more compelling are the observations that hyperaemic MBF quantification outperforms PET-derived CFR in the diagnosis of obstructive coronary artery disease, highlighting the potential of stress-only protocols77,78. Unfortunately, reported thresholds of what should be considered pathological hyperaemic MBF or CFR are not uniform across PET tracers22. Cut-off values seem to be, at least in part, related to tracer kinetics and should not be considered interchangeable.
In a contemporary study, PET had higher accuracy (85%) than coronary CT angiography (74%) or SPECT (77%) for the diagnosis of myocardial ischaemia when taking FFR as a reference standard40 (Fig. 4c). The comparative accuracy of PET versus CT or MRI perfusion, which have higher spatial resolution, remains to be determined. In terms of prognosis, analogy to large-scale SPECT databases exists79. The extent and severity of (reversible) perfusion defects documented with PET hold strong prognostic information beyond that obtained from traditional cardiovascular risk factors22. PET-derived CFR has shown added prognostic value for the identification of at-risk women with more frequent non-obstructive coronary artery disease and potential microvascular dysfunction57. Of particular interest is that apparently normal perfusion images with a homogeneous tracer distribution can be reclassified on the basis of diffusely blunted hyperaemic MBF or CFR; several studies have shown that this subset of patients is at increased risk of future cardiac events80–82.
Future developments
Both 15O-water and 13N-ammonia require the presence of an on-site cyclotron as a high upfront investment because of the short half-lives of both tracers (2 min and 9 min, respectively). By contrast, 82Rb (with a half-life of 1.3 min) is produced by a generator that has to be replaced on a monthly basis, which confers a high monthly cost but a low upfront investment. So-called baby cyclotrons have lower cost and are aimed specifically at the production of 13N or 15O and, therefore, also require lower energies and considerably less radiation shielding than common PET cyclotrons. This feature greatly increases the possibility of using 15O-water and 13N-ammonia in hospitals without PET chemistry facilities. 18F-flurpiridaz is a novel tracer that has shown higher accuracy than SPECT83 and also promises quantification using direct parametric reconstruction84. Furthermore, machine learning used for the integration of variables has great potential in clinical practice for identifying patients with myocardial ischaemia and increased risk of events25.
In summary, cardiac PET is the reference standard for the quantification of perfusion imaging. PET using parametric images showing MBF at the voxel level is now available in routine clinical practice, and PET also allows the derivation of the perfusable tissue index, which is a marker of myocardial viability, thereby expanding the clinical utility of this modality. On the basis of its characteristics, PET is well suited for patients with multivessel disease to confirm or exclude balanced ischaemia, and low-cost baby cyclotrons will improve the cost-effective use of PET.
Key points for PET
PET is the clinical reference standard for the quantification of myocardial perfusion.
Challenges of PET use include limited visual assessment of quantitative 15O-water PET and the lower spatial resolution of PET compared with CT or MRI perfusion imaging29,30.
Small or 13N-ammonia cyclotrons, as well as the availability of 18F-labelled tracers, could improve the cost-effectiveness of cardiac PET imaging, as well as logistics and dissemination.
Quantitative measures of myocardial ischaemia are provided with the addition of the measurement of viability and functional parameters during a single scan.
Hybrid imaging combining PET perfusion imaging with coronary CT angiography data might provide comprehensive assessment, especially in patients with multivessel disease.
MRI
Role in assessment of ischaemic heart disease
Since its inception85, myocardial perfusion MRI has evolved into a clinical modality with excellent sensitivity and specificity for detecting myocardial ischaemia86. Most clinical myocardial perfusion MRI approaches are based on dynamic contrast-enhanced imaging using exogenous gadolinium-based contrast agents. The absence of ionizing radiation and the increasing availability of MRI expertise and equipment promote its routine use to guide clinical interventions. All components of a comprehensive MRI examination (that is, ventricular function and late gadolinium enhancement for viability and perfusion) add synergistic information to prognosis87,88. Long-term follow-up data have demonstrated a strong and independent predictive value of myocardial perfusion MRI for future major adverse cardiac events and death89,90. The MR INFORM study91 demonstrated that, among patients with stable angina and risk factors for coronary artery disease, the use of myocardial perfusion MRI was associated with a lower incidence of coronary revascularization than the use of FFR and was non-inferior to FFR with respect to major adverse cardiac events.
Quantitative assessment of pathophysiology
Detailed technical characteristics of MRI are listed in Table 1. Although mostly visual or semiquantitative assessment is used to identify ischaemia in the clinic92, quantitative approaches93 have gained momentum with technical advances in MRI data acquisition, reconstruction and processing45,94. Quantitative perfusion analysis provides incremental prognostic value over semiquantitative and qualitative data analysis, with an area under the receiver operating characteristic curve (AUC) of 0.85 versus 0.75 (ref.88). Figure 5a summarizes the technical approaches used for qualitative, semiquantitative and quantitative MRI perfusion. Although imaging is typically performed by acquiring three 2D sequences along the short axis in a dynamic fashion, the feasibility of dynamic 3D, whole-heart imaging has been shown32. The conversion of signal intensity to contrast concentration is an important step for quantitative assessment (Fig. 5a). This process involves nonlinear mapping and dual sequence or dual bolus approaches to derive AIF95–97. In practice, a model-free Fermi function model has been widely used, and provides high accuracy and precision98 (Fig. 5a). Compared with Fermi models, distributed parameter models offer increased sensitivity (78% versus 96%) and specificity (88% versus 92%) by providing additional insights into changes in the permeability surface area and interstitial volumes evaluated99. Automated voxel-wise quantification offers faster assessment than the manual quantification of perfusion but has similar accuracy100. However, absolute measures remain variable because they are tightly connected to the MRI sequence, and a lack of standardization exists between systems41. An automated method for AIF detection on the basis of pixel thresholding reduces analysis time and produces similar MBF values to those derived from manual AIFs101.
Indications and clinical applications
MRI is less commonly used than SPECT but avoids ionizing radiation and allows the evaluation of patients with complex disease, who benefit from quantification of function, fibrosis and perfusion. Clinical indications for MRI are listed in detail in Fig. 2. Myocardial perfusion MRI has advanced substantially, with improved temporal resolution and the capacity to offer online automatic quantification in millilitres per gram per minute. The most important clinical application of absolute myocardial perfusion quantification is in patients with complex disease to address questions about multivessel disease, microvascular dysfunction102 or a combination of both103. Quantitative perfusion is also feasible in patients with heart failure and remodelled and thinned left ventricular walls, on the basis of the elevated spatial resolution allowed by cardiac MRI104. Methods for combined assessment of quantitative perfusion and left ventricular scar have been described105. T1 mapping can be used to differentiate between obstructive disease and microvascular dysfunction with higher accuracy than perfusion MRI and has produced similar mapping results in infarcted and ischaemic tissue106. In the large, single-centre CE-MARC study107, the AUC for perfusion MRI (0.89) was higher than that for SPECT (0.74) on the basis of visual assessment. This finding is in agreement with the secondary end points of the multicentre MR-IMPACT II study108 (Fig. 5b). However, quantitative MRI assessment in this study did not improve accuracy109, and the randomized, multicentre CE-MARC 2 study110 showed equal reductions in unnecessary invasive coronary angiography procedures using a diagnostic strategy on the basis of either MRI or SPECT. Compared with PET, quantitative perfusion MRI had a similar AUC of 0.83 for the detection of clinically significant coronary artery disease, but MRI perfusion values correlated only weakly with quantitative PET perfusion values, suggesting that further refinements are necessary111 (Fig. 5b). This refinement could be possible with perfusion mapping MRI, which has been shown to result in higher correlation with 13N-ammonia PET112 (Fig. 5b). However, most of these MRI studies used a limited spatial coverage of the left ventricle with only three cardiac short-axis slices, possibly resulting in missed diseases and limited spatial resolution with a slice thickness in the order of several PET voxel sizes. Another major challenge for the clinical application of MRI is its use in patients with cardiac devices, which nevertheless can be done safely when the pacing is changed to asynchronous mode for pacing-dependent patients or to demand mode for other patients, and tachyarrhythmia functions are disabled113. This approach might even allow cardiac MRI in patients with pacemakers or defibrillators, with interpretability not being limited by artefacts31.
Future developments
Free-breathing perfusion MRI with subsequent motion correction will make the procedure easier for patients114. Improved detection of myocardial ischaemia is possible using the gradientogram analysis, which has been validated in comparison with FFR115 (Fig. 5c). Although most quantitative imaging has focused on myocardial ischaemia owing to coronary obstructions, microvascular dysfunction including impairment of vessel compliance will be the focus of comprehensive cardiac MRI protocols. Given that microvascular dysfunction occurs diffusively and has a patchy distribution102, it can be differentiated from ischaemia caused by coronary obstructions using fractal analysis116 (Fig. 5c).
High-resolution, pixel-wise automated quantification enables MBF to be measured on a pixel-by-pixel basis and microvascular disease to be distinguished from obstructive disease (Fig. 5d). The ability to visualize subendocardial ischaemia, limiting partial volume effects and spatial averaging, is one of the main technical advantages of perfusion MRI, contributing to the elevated sensitivity of this method for the detection of ischaemia. Machine learning applied to myocardial perfusion MRI might improve quantification and, together with under-sampling, might reduce acquisition and reconstruction times27,117.
In summary, cardiac MRI is a comprehensive test to investigate myocardial perfusion, fibrosis and function. Several approaches to automating image acquisition, reconstruction and assessment will facilitate the clinical implementation of myocardial perfusion MRI. As MRI does not require ionizing radiation, this modality is especially suited for use in young patients. On the basis of its characteristics, MRI should be considered in patients with complex disease who would benefit from imaging of function and fibrosis in addition to perfusion.
Key points for perfusion MRI
MRI avoids ionizing radiation and allows detailed characterization of myocardial tissue.
Challenges associated with MRI application include the increased prevalence of pacemakers31, the limited spatial coverage of the left ventricle32 and the need for a method for adequate determination of arterial input function.
Dedicated image-acquisition protocols (dual sequence) or contrast agent injection schemes (dual bolus) are required for quantitative MRI perfusion analysis.
Automated voxel-wise quantification and dynamic 3D, whole-heart MRI could improve the detailed and complete assessment of myocardial ischaemia.
Evaluation of patients with complex disease is improved by the quantification of function, fibrosis and perfusion, and fractal analysis might allow obstructive and microvascular disease to be differentiated.
Echocardiography
Role in assessment of ischaemic heart disease
Echocardiography, like MRI, avoids ionizing radiation but can be performed at the bedside. Contrast echocardiography using microbubble tracers improves image quality and reproducibility in the assessment of global and regional left ventricular function118,119. The microbubbles consist of a gas core and typically a lipid or albumin shell. Ultrasound microbubbles remain entirely intravascular and can oscillate in resonance, producing the signals from individual microbubbles120. During infusion and steady state, signals emanating from microbubbles reflect the relative microvascular blood volume121. Microbubbles can be cleared from the myocardium by applying a series of high-power ultrasound pulses, and the myocardial replenishment is assessed by reverting to low-power imaging (Fig. 6a). This approach allows the myocardial blood velocity to be estimated as a semiquantitative measure of myocardial ischaemia121 both at rest and during stress (Fig. 6b). Echocardiography is the preferred technique in bedside situations, for instance in patients with suspected acute coronary syndrome, and can be useful in chronic myocardial ischaemia if good acoustic conditions are present. As collaterals supply blood to the myocardium, myocardial contrast echocardiography allows quantitative assessment of MBF subtended by an occluded artery. An association exists between collateral blood flow and myocardial viability after a recent myocardial infarction, as shown by quantitative myocardial contrast echocardiography122, which also accurately detects multivessel disease123. Using vasodilator stress, hyperaemic flow can be assessed in each of the 16 segments of the left ventricle, and CFR is calculated by dividing hyperaemic MBF by MBF during rest124. A good agreement has been shown between CFR measured by echocardiography and FFR, with the greatest discordance in symptomatic patients with normal FFR125. Echocardiography can also be used to assess viability in akinetic myocardial segments by assessing the microvasculature, which is present in viable but not necrotic tissue126.
Quantitative assessment of pathophysiology
Detailed technical characteristics of echocardiography are listed in Table 1. Quantitative assessment of myocardium perfusion can be achieved through destruction–reperfusion imaging and analysis of the time–intensity curves from different regions of interest in the myocardium (Fig. 6). Quantitative myocardial perfusion at rest has been shown to predict viable myocardium after myocardial infarction and in chronic coronary artery disease118. MBF reserve assessed during hyperaemic echocardiography has been shown to be associated with the severity of coronary stenosis in patients with stable angina118. In a meta-analysis, MBF reserve had high accuracy for the prediction of flow-limiting coronary artery disease118 and could be used to determine the pathophysiological basis of microcirculatory angina127.
Indications and clinical applications
Clinical indications for echocardiography are listed in detail in Fig. 2. Prospective studies including one randomized trial have investigated the use of contrast echocardiography for the detection of myocardial ischaemia (Fig. 6c) and its use for risk stratification of patients with known or suspected coronary artery disease, in both the acute and outpatient settings128–132. However, reliable quantification of myocardial perfusion remains elusive and sometimes even qualitative assessment can be challenging133,134. This limitation is first and foremost owing to variability in image quality (Fig. 6d). The common presence of noise and artefacts is an important factor that, in turn, affects the reproducibility of contrast echocardiography. This problem is particularly relevant for stress echocardiography, in which both high image quality and frame rates are required. In addition, limitations of the acoustic window can further diminish the signal-to-noise ratio. Echocardiography is ubiquitously available, is a bedside technique without ionizing radiation and is a preferred imaging technique among experienced operators in patients with acute chest pain.
Future developments
An important challenge for echocardiography is the lack of automated quantification techniques and software. Although various physical and human factors affecting quantification are known and can be accounted for135, automated myocardial segmentation remains challenging owing to speckle noise and 3D deformations. Artificial intelligence solutions using machine learning for automated myocardial segmentation on contrast echocardiography are being developed136. These techniques promise automated and fast segmentation and perfusion quantification. High frame rate ultrasonography with up to 6,000 frames per second can be achieved through parallel data acquisition and digital beam forming. This approach offers image processing opportunities to increase the signal-to-noise ratio (Fig. 6c–e). High frame rate echocardiography can reveal the coronary microvasculature even without contrast but only in fairly shallow regions137. The feasibility of high frame rate contrast echocardiography for myocardial perfusion imaging in humans has been reported33. With this quantification, existing challenges might be addressed but its clinical utility needs further evaluation. In addition to high frame rate echocardiography, new 3D imaging138 might help to address the clinical application challenges discussed above.
In summary, echocardiography is a readily available bedside imaging test for which contrast-enhanced ultrasound applications using microbubbles have enabled semiquantitative measures of perfusion. High frame rate ultrasonography might overcome the major image quality issues that are often present during echocardiography, such as low signal-to-noise ratio and artefacts. Automated segmentation and 3D imaging will facilitate echocardiography. On the basis of its characteristics, echocardiography should be considered when bedside imaging is required.
Key points for echocardiography
Echocardiography is most commonly applied for cardiac function imaging but is increasingly also being used for the assessment of myocardial perfusion and can be performed at the bedside.
The challenges of echocardiography include the common presence of noise and artefacts, lack of reproducibility, variable image quality and time-consuming manual analysis33.
High frame rate echocardiography allows the estimation of myocardial blood velocity as a semiquantitative measure of myocardial ischaemia with improved image quality.
Artificial intelligence solutions using machine learning for automated myocardial segmentation promise automated and fast segmentation and perfusion quantification.
Evaluation of patients with suspected acute coronary syndrome at the bedside is the primary strength of echocardiography when performed by experienced operators.
Cardiac CT
Role in assessment of ischaemic heart disease
Cardiac CT is widely available with widespread clinical application for noninvasive coronary angiography and has a class I (level of evidence B) recommendation in the 2019 European guidelines, together with functional imaging, for use in individuals with a low-to-intermediate clinical likelihood of coronary artery disease4. However, stenosis grading by CT is limited in its capacity to predict ischaemia139, and CT perfusion imaging is not frequently used. For appropriate spatial coverage, >64 CT detector rows are recommended, while 256-row and 320-row CT provides whole-heart coverage in one heartbeat. For myocardial CT perfusion imaging, static imaging either with or without a vasodilator stressor (such as adenosine) is used, whereas dynamic (4D) imaging allows the quantification of MBF but requires multiple scans over time. Dynamic CT perfusion imaging might provide the greatest clinical value but challenges with this modality include increased radiation dose, motion artefacts and image quality limitations140. A meta-analysis showed higher sensitivity (0.85 versus 0.72) but lower specificity (0.81 versus 0.90) for dynamic compared with static CT perfusion imaging141. The greatest role of CT in relation to myocardial ischaemia might be in stenosis and plaque quantification.
Quantitative assessment of pathophysiology
Detailed technical characteristics of CT are listed in Table 1. Advantages of CT include its high spatial resolution and the linear relationship between image attenuation, measured in Hounsfield units, and myocardial contrast agent concentration. Therefore, myocardial perfusion can, in principle, be measured quantitatively (absolute MBF)142 (Fig. 7a) and/or semiquantitatively (static imaging)143,144.
Furthermore, microvascular disease in addition to collateral circulation specifically in patients with occluded vessels can also be evaluated145,146. Although absolute quantification of ischaemia is possible, the added value over semiquantitative assessment is uncertain147. Current CT scanners are challenged by beam-hardening artefacts, limited temporal resolution resulting in cardiac motion artefacts and low contrast-to-noise ratios. Beam-hardening artefacts can be reduced using dedicated correction methods34–36. Temporal resolution can be improved by a higher rotation speed, dual-source CT or post-acquisition algorithms that estimate motion in order to compensate for it during image reconstruction37. Image acquisition during systole has the potential to improve CT perfusion image analysis, whereas β-blockers, which are often required for coronary CT angiography, might diminish the subsequent intended effects of vasodilator stressors148.
Indications and clinical applications
Cardiac CT has undergone exponential growth in the past decade, and clinical indications are listed in detail in Fig. 2. Coronary CT angiography is included in clinical guidelines as a diagnostic tool in stable patients with chest pain and an intermediate pretest probability of obstructive coronary artery disease1,3,4. However, in patients with heavily calcified or stented coronary lesions, the addition of CT perfusion to CT angiography improves diagnostic accuracy from 71% to 87%149. Using combined CT angiography and CT perfusion might therefore reduce the number of unnecessary invasive coronary angiography procedures performed150,151. To identify patients in whom coronary revascularization might relieve myocardial ischaemia, myocardial CT perfusion imaging147 and computational fluid dynamics modelling to estimate FFR by CT have been investigated152,153. The international CORE320 study154 was the first to demonstrate that the combination of static CT myocardial perfusion imaging and coronary CT angiography can correctly identify coronary stenosis associated with myocardial ischaemia by SPECT, and this finding has been corroborated in a meta-analysis155. Initial experience suggests that the combination of CT myocardial perfusion imaging and FFR estimated by CT can provide an even higher diagnostic accuracy, with an improvement in the AUC from 0.78 to 0.85 (ref.156). Importantly, computational fluid dynamics modelling to estimate FFR relies on mathematical assumptions and equal responses by the microcirculation to vasodilators. Moreover, and in contrast to invasive FFR, noninvasively estimated FFR does not account for collateral flow in the same manner157. To what extent the implementation of CT–FFR will translate into improved patient outcomes still needs to be elucidated. Of note, a meta-analysis showed that CT perfusion has a higher specificity than CT–FFR (86% versus 78%)141. The randomized CATCH-2 trial158 demonstrated that the addition of CT myocardial perfusion imaging to coronary CT angiography alone safely reduces the need for invasive examination and treatment (Fig. 7a). The CRESCENT II trial159 demonstrated the benefit of a tiered CT protocol with limited use of CT perfusion only if CT angiography shows a ≥50% stenosis, which led to more appropriate revascularization indications than functional testing (88% versus 50%). In a two-centre study, semiquantitative static CT myocardial perfusion imaging achieved a similar performance to perfusion MRI compared with the reference standard of invasive angiography and SPECT160. This finding was supported in a meta-analysis, which showed similar negative likelihood ratios for perfusion imaging using PET, MRI or CT of 0.14, 0.14 and 0.12, respectively73. Importantly, in the 2-year follow-up of the CORE320 study161, the combination of CT angiography and semiquantitative CT perfusion showed similar accuracy in predicting cardiovascular events to invasive coronary angiography and SPECT combined. In another single-centre study, MBF derived from dynamic CT perfusion had independent predictive value, with a hazard ratio of 5.7 when adjusted for obstructive coronary artery disease on CT angiography162.
Future developments
Two-compartment analysis might reduce underestimation of MBF by CT163,164, and the semiquantitative transmural perfusion ratio might improve diagnosis of myocardial ischaemia compared with using the MBF165. Low kilovolt scanning (70–80 kV) enables a substantial reduction in radiation dose, while increasing contrast-to-noise ratio166. New photon-counting energy-selective X-ray detectors are being developed for improved contrast and reduced radiation dose167 (Fig. 7b). Algorithmic solutions will further improve contrast and reduce noise168. Four-dimensional, non-rigid motion correction will allow visual interpretation and pave the way for quantitative assessment of the 2–3 billion voxels acquired during dynamic CT perfusion imaging169. Convolutional neural networks will reduce artefacts (Fig. 7c) by predicting high-quality images from low-dose CT170,171. Sparse-view CT is a futuristic way of reducing radiation dose in which the dose-emitting source is masked at different angular positions during gantry rotation. The resulting structured CT image artefacts might be corrected using deep neural networks26, and accurate scatter correction might become possible using deep learning, which is much faster than using Monte Carlo simulations172.
In summary, CT perfusion is rarely used but theoretically well suited for quantification of myocardial perfusion in addition to its capacity noninvasively to exclude obstructive coronary stenosis and to characterize coronary atherosclerosis173. Low kilovolt scanning, new CT detector technology and algorithmic solutions are promising approaches to reducing CT radiation dose and image artefacts. On the basis of these characteristics, the greatest value of CT in relation to myocardial ischaemia is for the combined assessment of stenosis and atherosclerosis.
Key points for CT
CT perfusion imaging is not frequently used, whereas CT angiography offers highly accurate coronary angiography.
Challenges of cardiac CT include limited temporal resolution, beam and scatter artefacts, radiation dose and low contrast-to-noise ratios34–37.
CT systems with increased rotation speed, photon-counting energy-selective X-ray detectors and advanced machine learning technology, as well as two-compartment analysis could overcome the technological challenges.
The combined assessment of stenosis and characterization of atherosclerosis in relation to myocardial ischaemia promises the greatest clinical value but requires testing in trials.
Evaluation of patients with insufficient angiographic image quality or borderline stenosis on coronary CT angiography might be improved with the use of CT for myocardial ischaemia.
Invasive coronary flow and pressure
Role in assessment of ischaemic heart disease
Invasive coronary physiology techniques have an increasing role in the clinical assessment of stenosis-induced myocardial ischaemia. Their availability during catheterization allows informed decision-making about coronary revascularization directly in the catheterization laboratory174. Invasive coronary flow and pressure measurement is recommended in clinical guidelines to guide decision-making in the absence of noninvasive stress testing results1. To enable better decision-making in these situations, the advantages and limitations of coronary physiology techniques in clinical practice must be recognized.
Quantitative assessment of pathophysiology
Detailed technical characteristics of invasive coronary flow and pressure measurement are listed in Table 1. The most widely adopted invasive approach to pathophysiology is (myocardial) FFR, which is calculated as the ratio of mean distal coronary pressure to mean aortic pressure during pharmacologically induced coronary vasodilatation (Fig. 8a). The aim of FFR is to quantify the impairment of maximal coronary flow induced by a stenosis from invasive coronary pressure measurement175. FFR-guided coronary interventions substantially reduce the need for revascularization procedures compared with decision-making by visual assessment alone and leads to similar long-term clinical outcomes176. However, two important issues remain. First, the adoption of FFR guidance remains limited to <6% of patients in most countries globally, with only a few exceptions38. This situation is in stark contrast to clinical guidelines, which advocate the widespread use of invasive coronary measurements. Furthermore, noninvasive ischaemia imaging tests are used in only 64% of all patients before coronary angiography150,151. Second, the prognostic value of FFR in patients with stenoses and an abnormal FFR is limited, with 27% of patients who are managed by medical therapy alone having a cardiovascular event within 5 years39. This finding calls into question the clinical practice guidelines advocating revascularization in all vessels with an abnormal FFR1. The limited adoption of FFR is related to practical and economic issues as the procedure is both time-consuming and costly. Some of these problems can be addressed by the use of simpler measurements, such as the instantaneous wave-free ratio (iFR) or resting distal coronary-to-aortic pressure ratio (Pd/Pa). iFR is defined as the ratio of distal coronary pressure to aortic pressure at a distinct time in cardiac diastole, termed the wave-free period (Fig. 8a), in resting, non-vasodilated conditions177. The diagnostic efficiency of FFR and iFR for haemodynamically significant coronary stenoses is similar to that of SPECT or PET38. Moreover, an iFR-guided revascularization strategy has been documented to provide equivalent clinical outcomes to those of an FFR-guided strategy in two large randomized clinical trials, where fewer coronary revascularization procedures were indicated in the iFR-guided treatment groups178,179.
Importantly, pressure-based measurements provide an estimate of stenosis-induced flow impairment, but they are different from coronary flow or CFR, which determine ischaemia. CFR is defined as the ratio of coronary flow during pharmacological vasodilatation to flow at rest (Fig. 8a), representing the reserve capacity of the coronary circulation to increase flow in response to increased demand. A lower CFR is linked to symptoms of ischaemia and is predictive of myocardial infarction and death. A challenge is that coronary pressure-derived estimates of flow impairment do not correlate with measured CFR in 30–40% of patients132,133 (Fig. 8b). This situation arises because physiology dictates that an increase in coronary flow leads to lower (abnormal) FFR but higher (normal) CFR and vice versa180. This observation suggests that combined FFR and CFR is better for identifying the individual pathophysiology and predicting clinical outcomes132 (Fig. 8c).
FFR and iFR are considered to estimate the effect of the stenosis on distal MBF, thereby taking into account the effect of collateral flow to the myocardium of interest. For FFR, coronary FFR can be calculated, which is the FFR in the coronary artery when excluding the effect of collateral flow. However, myocardial FFR has been studied in clinical outcome trials and is used in daily clinical practice. Nonetheless, coronary collateral flow can be assessed directly using invasive coronary pressure and flow measurements in several ways. Coronary wedge pressure, which is the distal coronary pressure obtained during occlusion of the epicardial coronary artery to prevent antegrade coronary flow, is a simple marker of collateral function. Furthermore, collateral blood flow can be quantified in more detail using either flow velocity or coronary pressure measurements. The Doppler velocity-derived collateral flow index (CFI) is calculated as the intracoronary flow velocity integral (CFVI) during balloon occlusion as a fraction of CFVI during coronary patency. The coronary pressure-derived CFI (CFIp; also called collateral FFR) is calculated as the coronary wedge pressure minus venous back pressure as a fraction of the aortic pressure minus venous back pressure. When both Doppler velocity and coronary pressure measurements are performed, the total collateral resistance can also be calculated, as well as the individual resistances in the components of the collateral pathway. CFI and CFIp are the most applicable techniques, and values of >0.30 are generally considered to indicate adequate collateral artery function, substantiated by the absence of angina or electrocardiogram changes during balloon occlusion181.
Indications and clinical applications
Clinical indications for invasive approaches are listed in detail in Fig. 2. In patients with a high likelihood of invasive treatment being required, invasive coronary flow and pressure measurement is well suited to guide treatment decision-making, with FFR having achieved greatest acceptance but limited clinical uptake38. This situation might be improved using less complex invasive measurements, such as iFR, which compared with an FFR-guided strategy leads to fewer revascularizations while providing equivalent 1-year clinical outcomes178,179. Resting Pd/Pa has so far been investigated only in diagnostic studies and has shown similar accuracy to iFR182. Considering the limitations of coronary pressure-based techniques, the decision to revascularize should optimally be on the basis of the combination of imaging ischaemia tests and coronary pressure measurement, the results of which should be interpreted in relation to the symptoms of the individual patient to determine the risk–benefit ratio of a coronary intervention.
Future developments
The suboptimal discriminative value of FFR can be addressed by the (additional) direct measurement of coronary flow, instead of its estimation from coronary pressure measurement180. This approach is currently being evaluated in a multicentre setting in the DEFINE-FLOW study183. Meanwhile, it is important to realize that the current technology for direct flow measurement is fairly outdated and technically demanding, and substantial technical revisions are expected shortly. However, current ischaemia-guided or coronary pressure-guided coronary interventions are already superior to angiography-based decision-making alone176,178,179. Artificial intelligence, mainly in the form of machine learning and intelligent algorithms, is increasingly being recognized as a tool to aid invasive diagnostics184 and to improve the safety and accuracy of invasive physiology techniques. Examples are the automated interpretation of aortic pressure traces and iFR pullback traces to identify inaccurate pressure readings that might influence FFR and/or iFR values or their interpretation and affect decision-making.
In summary, FFR measurements can substantially reduce the need for revascularization compared with visual assessment alone, without impairing long-term clinical outcomes. However, the limited uptake of invasive measurement of FFR in clinical practice is related to the complexity of the procedure, which can be overcome using measurement of iFR and Pd/Pa. The combined measurement of pressure and flow should have the highest discriminative capacity and prognostic value but requires further testing. On the basis of their characteristics, invasive measurements have the greatest value in patients with a high likelihood of requiring invasive treatment.
Key points for invasive coronary flow and pressure measurement
Invasive catheter-based methods can be used to measure coronary flow and pressure.
Challenges of invasive coronary flow and pressure measurements include the diagnostic and prognostic characteristics of FFR, the complexity of the procedure and its limited uptake in clinical practice (used in <6% of patients38,39).
iFR and resting Pd/Pa are simpler than FFR but have similar prognostic and diagnostic value and might improve the clinical uptake of coronary pressure measurements.
The combined assessment of CFR and FFR promises the greatest discriminative value for individual pathophysiology but requires testing in trials.
In patients with a high likelihood of requiring invasive treatment, invasive coronary flow and pressure measurement is well suited to guide treatment decision-making.
Invasive coronary pressure and flow measurements allow coronary collateral function to be quantified.
Artificial intelligence might further improve the accuracy and interpretation of coronary pressure readings and could improve coronary flow assessment.
Conclusions
Current cardiac imaging modalities offer widespread utility to assess myocardial ischaemia quantitatively, without the risks of invasive investigation. Among the myocardial perfusion imaging tests, PET is the reference standard for quantification, and SPECT is most commonly used. Although MRI is less commonly used than SPECT, MRI avoids ionizing radiation, as does echocardiography. Echocardiography has similar advantages to those of MRI and can be performed at the bedside. CT is not frequently used for perfusion imaging but offers coronary angiography including assessment of plaque burden and can provide a geometric framework for model-based estimation of CT–FFR. Intracoronary measurements of pressure and flow velocity provide comprehensive haemodynamic information to guide invasive treatment. All six ischaemia imaging techniques have distinct advantages and disadvantages (Table 1).
The diagnostic potential of these imaging techniques is substantially improved by technical advances that can yield quantitative measures of myocardial perfusion. Dedicated cardiac SPECT cameras have emerged for improved sensitivity and resolution at lower doses of radiation, and dynamic imaging enables compartmental modelling and thereby provides absolute measures of myocardial ischaemia. Small cyclotrons and the availability of 18F-labelled PET tracers could improve logistics, and hybrid PET–CT might provide comprehensive assessment, especially in patients with multivessel disease. Automated voxel-wise perfusion quantification of whole-heart MRI could improve the assessment of myocardial ischaemia to facilitate the evaluation of patients with complex disease and the differentiation between obstructive and microvascular disease. High frame rate echocardiography allows the estimation of myocardial blood velocity with improved image quality, and machine learning can be used for automated and fast myocardial segmentation. CT with increased rotation speed, photon-counting detectors and machine learning could overcome temporal resolution challenges, beam and scatter artefacts, and low contrast-to-noise ratios of CT perfusion imaging for use in patients with borderline coronary stenosis on CT angiography. Invasive coronary measurements of iFR and resting Pd/Pa is simpler than measurement of FFR but have similar prognostic and diagnostic value and might improve the so-far limited uptake of coronary pressure measurements. The combined assessment of CFR and FFR provides the greatest promise in discriminating individual pathophysiologies.
No single quantitative perfusion imaging technique is best for all types of patient, for all disease stages or at all clinical centres, as usage also depends on the availability of local expertise. Using a Delphi consensus process, we have identified the most appropriate clinical scenario for each diagnostic test for myocardial ischaemia (Fig. 2). SPECT with the use of new detectors allows quantification of MBF and is also suited to quantification in patients with a high BMI. PET should be the primary test in patients with multivessel disease to confirm or exclude balanced ischaemia. MRI allows the evaluation of patients with complex disease who would benefit from imaging of cardiac function and myocardial fibrosis in addition to perfusion. Echocardiography is the preferred technique for assessing acute coronary syndrome in bedside situations. CT has greatest value for combined quantification of stenosis and characterization of atherosclerosis in relation to myocardial ischaemia. In patients with a high likelihood of requiring invasive treatment, invasive coronary flow and pressure measurement is well suited to guide treatment decision-making.
All imaging modalities share the requirement to take coronary pathophysiology into account in the interpretation of noninvasive perfusion imaging and invasive coronary pressure and flow data. Quantification of myocardial perfusion by imaging can provide accurate measures of the burden of ischaemia to determine individualized treatment strategies. This assessment is very important because the ORBITA study134 showed that a much more comprehensive, pre-catheterization, quantitative, multimodality imaging strategy is required in patients with suspected ischaemia. This approach helps to identify the most appropriate treatment strategy with or without coronary revascularization and might translate into lower morbidity and mortality. Therefore, in the time of personalized medicine, perfusion imaging provides robust, quantitative assessment of myocardial ischaemia that can be used to guide individual risk stratification and direct treatment decision-making. Future studies will incorporate the emerging computational support of machine learning to benefit complex decision-making about the need for coronary revascularization.
Supplementary information
Acknowledgements
We thank the German Research Foundation’s Heisenberg Program for enabling the first Quantitative Cardiac Imaging meeting and Consensus Statement on the quantitative assessment of myocardial ischaemia with a grant to M.D. (DE 1361/14-1, project number 213705389). We thank B. Herwig (Department of Radiology, Charité, Berlin, Germany) for editorial assistance and E. Klotz (Siemens Healthineers) for his lecture during the meeting, which influenced the discussion at the first Quantitative Cardiac Imaging meeting, although he was not involved in the decisions made in this Consensus Statement.
Author contributions
M.D., M.S., J.M. and L.S. wrote the first draft of the Introduction, which was reviewed and edited by all authors. M.D. wrote the first draft of the Methods, which was reviewed and edited by all authors. K.F.K. and M.K. wrote the first draft of the CT section, which was edited by M.D., P.M.-H., K.N., W.B., A.K. and L.S. before all authors reviewed and revised this section. R.M. and S.K. wrote the first draft of the MRI section, which was edited by M.D., A.C., T.S., F.M. and L.S. before all authors reviewed and revised this section. F.B. and S.N. wrote the first draft of the SPECT section, which was edited by M.D., P.K. and M.L. before all authors reviewed and revised this section. P.K. and M.L. wrote the first draft of the PET section, which was edited by M.D., F.B. and S.N. before all authors reviewed and revised this section. R.S. and M.-X.T. wrote the first draft of the echocardiography section, which was edited by M.D. and T.v.d.H. before all authors reviewed and revised this section. J.J.P. and T.v.d.H. wrote the first draft of the FFR and iFR section, which was edited by M.D., R.S. and M.-X.T. before all authors reviewed and revised this section. All methodological and clinical authors participated in the Delphi development and evaluation process, which was coordinated by A.K. All authors contributed to researching data and discussion of content. All authors reviewed and edited the entire manuscript before submission.
Competing interests
M.D. reports grants from the German Research Foundation’s (DFG) Heisenberg Program for the first Quantitative Cardiac Imaging meeting and Consensus Statement on quantitative assessment of myocardial ischaemia. M.D. reports further grant support from the Berlin Institute of Health’s Digital Health Accelerator program; F.M. is partially employed through this program. Institutional master research agreement grants with Siemens Healthineers, Philips Medical Systems and Canon Medical Systems exist at Charité, which are handled by the legal department. M.D. reports grants from the FP7 Program of the European Commission for the DISCHARGE project, grants from DFG and the German Ministry of Education and Research (BMBF) for individual patient data meta-analyses on cardiac imaging, honoraria for speaking from Bayer, Canon, Cardiac MR Academy Berlin and Guerbet, royalties as an editor of Cardiac CT published by Springer, and organization of Charité hands-on courses on cardiac CT imaging. M.D. and T.S. are also principal investigators of the BIOQIC graduate programme at Charité, which is funded by the DFG; A.K. is a PhD student in this graduate programme. M.S. received institutional support from the University of Texas Health Science Center at Houston for the DEFINE-FLOW project (NCT02328820). W.B. is supported by the SmartHeart EPSRC Program Grant (EP/P001009/1). T.S and A.C. report grant support from the EMPIR project 15HLT05 PerfusImaging. F.B. reports grant support and speaker honoraria from GE Healthcare and Siemens AG. S.N. receives research funding from the DFG, Horizon2020 and Siemens Healthineers. M.L. is supported by grants and speaker honoraria from GE Healthcare and is a co-founder of MedTrace Pharma AS. M.-X.T. reports grant support from the UK EPSRC (EP/M011933/1) and the British Heart Foundation (PG/16/95/32350). J.J.P. and T.v.d.H. report serving as speakers at educational events organized by Boston Scientific, Philips-Volcano and St. Jude Medical (now Abbott Vascular), which are manufacturers of sensor-equipped guide wires. J.M. and L.S. report grants from the BMBF (01EO1504, 01EO1504) and Siemens Healthineers, Germany. The other authors declare no competing interests.
Footnotes
Publisher’s note
Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
Related link
Delphi process: http://www.millennium-project.org/rtd-general/
Supplementary information
Supplementary information is available for this paper at 10.1038/s41569-020-0341-8.
References
- 1.Montalescot G, et al. 2013 ESC guidelines on the management of stable coronary artery disease: the Task Force on the management of stable coronary artery disease of the European Society of Cardiology. Eur. Heart. J. 2013;34:2949–3003. doi: 10.1093/eurheartj/eht296. [DOI] [PubMed] [Google Scholar]
- 2.Fihn SD, et al. 2012 ACCF/AHA/ACP/AATS/PCNA/SCAI/STS guideline for the diagnosis and management of patients with stable ischemic heart disease: a report of the American College of Cardiology Foundation/American Heart Association Task Force on Practice Guidelines, and the American College of Physicians, American Association for Thoracic Surgery, Preventive Cardiovascular Nurses Association, Society for Cardiovascular Angiography and Interventions, and Society of Thoracic Surgeons. J. Am. Coll. Cardiol. 2012;60:e44–e164. doi: 10.1016/j.jacc.2012.07.013. [DOI] [PubMed] [Google Scholar]
- 3.Hoffmann U, et al. ACR appropriateness criteria acute nonspecific chest pain-low probability of coronary artery disease. J. Am. Coll. Radiol. 2015;12:1266–1271. doi: 10.1016/j.jacr.2015.09.004. [DOI] [PubMed] [Google Scholar]
- 4.Knuuti J, et al. 2019 ESC guidelines for the diagnosis and management of chronic coronary syndromes. Eur. Heart J. 2020;41:407–477. doi: 10.1093/eurheartj/ehz425. [DOI] [PubMed] [Google Scholar]
- 5.van den Wijngaard JP, et al. 3D imaging of vascular networks for biophysical modeling of perfusion distribution within the heart. J. Biomech. 2013;46:229–239. doi: 10.1016/j.jbiomech.2012.11.027. [DOI] [PubMed] [Google Scholar]
- 6.van Horssen P, Siebes M, Spaan JA, Hoefer IE, van den Wijngaard JP. Innate collateral segments are predominantly present in the subendocardium without preferential connectivity within the left ventricular wall. J. Physiol. 2014;592:1047–1060. doi: 10.1113/jphysiol.2013.258855. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 7.van Lier MG, et al. Transmural distribution and connectivity of coronary collaterals within the human heart. Cardiovasc. Pathol. 2016;25:405–412. doi: 10.1016/j.carpath.2016.06.004. [DOI] [PubMed] [Google Scholar]
- 8.Seiler C, Meier P. Historical aspects and relevance of the human coronary collateral circulation. Curr. Cardiol. Rev. 2014;10:2–16. doi: 10.2174/1573403X113099990028. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 9.Pries AR, et al. Coronary vascular regulation, remodelling, and collateralization: mechanisms and clinical implications on behalf of the working group on coronary pathophysiology and microcirculation. Eur. Heart J. 2015;36:3134–3146. doi: 10.1093/eurheartj/ehv100. [DOI] [PubMed] [Google Scholar]
- 10.Niccoli G, Scalone G, Crea F. Acute myocardial infarction with no obstructive coronary atherosclerosis: mechanisms and management. Eur. Heart J. 2015;36:475–481. doi: 10.1093/eurheartj/ehu469. [DOI] [PubMed] [Google Scholar]
- 11.Spaan JA, Piek JJ, Hoffman JI, Siebes M. Physiological basis of clinically used coronary hemodynamic indices. Circulation. 2006;113:446–455. doi: 10.1161/CIRCULATIONAHA.105.587196. [DOI] [PubMed] [Google Scholar]
- 12.van de Hoef TP, et al. Coronary pressure-flow relations as basis for the understanding of coronary physiology. J. Mol. Cell. Cardiol. 2012;52:786–793. doi: 10.1016/j.yjmcc.2011.07.025. [DOI] [PubMed] [Google Scholar]
- 13.Goodwill AG, Dick GM, Kiel AM, Tune JD. Regulation of coronary blood flow. Compr. Physiol. 2017;7:321–382. doi: 10.1002/cphy.c160016. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 14.Hanley FL, Messina LM, Grattan MT, Hoffman IE. The effect of coronary inflow pressure on coronary vascular resistance in the isolated dog heart. Circ. Res. 1984;54:760–772. doi: 10.1161/01.res.54.6.760. [DOI] [PubMed] [Google Scholar]
- 15.Uren NG, et al. Relation between myocardial blood flow and the severity of coronary-artery stenosis. N. Engl. J. Med. 1994;330:1782–1788. doi: 10.1056/NEJM199406233302503. [DOI] [PubMed] [Google Scholar]
- 16.Verhoeff BJ, et al. Influence of percutaneous coronary intervention on coronary microvascular resistance index. Circulation. 2005;111:76–82. doi: 10.1161/01.CIR.0000151610.98409.2F. [DOI] [PubMed] [Google Scholar]
- 17.Chareonthaitawee P, Kaufmann PA, Rimoldi O, Camici PG. Heterogeneity of resting and hyperemic myocardial blood flow in healthy humans. Cardiovasc. Res. 2001;50:151–161. doi: 10.1016/s0008-6363(01)00202-4. [DOI] [PubMed] [Google Scholar]
- 18.Deussen A. Blood flow heterogeneity in the heart. Basic Res. Cardiol. 1998;93:430–438. doi: 10.1007/s003950050112. [DOI] [PubMed] [Google Scholar]
- 19.Bache RJ, Cobb FR. Effect of maximal coronary vasodilation on transmural myocardial perfusion during tachycardia in the awake dog. Circ. Res. 1977;41:648–653. doi: 10.1161/01.res.41.5.648. [DOI] [PubMed] [Google Scholar]
- 20.Danad I, et al. Impact of anatomical and functional severity of coronary atherosclerotic plaques on the transmural perfusion gradient: a [15O]H2O PET study. Eur. Heart. J. 2014;35:2094–2105. doi: 10.1093/eurheartj/ehu170. [DOI] [PubMed] [Google Scholar]
- 21.Fokkema DS, et al. Diastolic time fraction as a determinant of subendocardial perfusion. Am. J. Physiol. Heart Circ. Physiol. 2005;288:H2450–H2456. doi: 10.1152/ajpheart.00790.2004. [DOI] [PubMed] [Google Scholar]
- 22.Gould KL, et al. Anatomic versus physiologic assessment of coronary artery disease. Role of coronary flow reserve, fractional flow reserve, and positron emission tomography imaging in revascularization decision-making. J. Am. Coll. Cardiol. 2013;62:1639–1653. doi: 10.1016/j.jacc.2013.07.076. [DOI] [PubMed] [Google Scholar]
- 23.Jerosch-Herold M, Wilke N. MR first pass imaging: quantitative assessment of transmural perfusion and collateral flow. Int. J. Card. Imaging. 1997;13:205–218. doi: 10.1023/a:1005784820067. [DOI] [PubMed] [Google Scholar]
- 24.Hu LH, et al. Machine learning predicts per-vessel early coronary revascularization after fast myocardial perfusion SPECT: results from multicentre REFINE SPECT registry. Eur. Heart J. Cardiovasc. Imaging. 2019 doi: 10.1093/ehjci/jez177. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 25.Juarez-Orozco LE, et al. Machine learning in the integration of simple variables for identifying patients with myocardial ischemia. J. Nucl. Cardiol. 2018 doi: 10.1007/s12350-018-1304-x. [DOI] [PubMed] [Google Scholar]
- 26.Kofler A, Wald C, Dewey M. Radiation dose reduction in cardiac CT: removing sparse view CT artifacts with deep learning [abstract 99] J. Cardiovasc. Comput. Tomogr. 2018;12:S42. [Google Scholar]
- 27.Leiner T, et al. Machine learning in cardiovascular magnetic resonance: basic concepts and applications. J. Cardiovasc. Magn. Reson. 2019;21:61. doi: 10.1186/s12968-019-0575-y. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 28.Agostini D, et al. Performance of cardiac cadmium-zinc-telluride gamma camera imaging in coronary artery disease: a review from the Cardiovascular Committee of the European Association of Nuclear Medicine (EANM) Eur. J. Nucl. Med. Mol. Imaging. 2016;43:2423–2432. doi: 10.1007/s00259-016-3467-5. [DOI] [PubMed] [Google Scholar]
- 29.Harms HJ, et al. Comparison of clinical non-commercial tools for automated quantification of myocardial blood flow using oxygen-15-labelled water PET/CT. Eur. Heart J. Cardiovasc. Imaging. 2014;15:431–441. doi: 10.1093/ehjci/jet177. [DOI] [PubMed] [Google Scholar]
- 30.Driessen RS, et al. Measurement of LV volumes and function using oxygen-15 water-gated PET and comparison with CMR imaging. JACC Cardiovasc. Imaging. 2016;9:1472–1474. doi: 10.1016/j.jcmg.2016.01.014. [DOI] [PubMed] [Google Scholar]
- 31.Lupo P, et al. An eight-year prospective controlled study about the safety and diagnostic value of cardiac and non-cardiac 1.5-T MRI in patients with a conventional pacemaker or a conventional implantable cardioverter defibrillator. Eur. Radiol. 2018;28:2406–2416. doi: 10.1007/s00330-017-5098-z. [DOI] [PubMed] [Google Scholar]
- 32.Manka R, et al. Multicenter evaluation of dynamic three-dimensional magnetic resonance myocardial perfusion imaging for the detection of coronary artery disease defined by fractional flow reserve. Circ. Cardiovasc. Imaging. 2015;8:e003061. doi: 10.1161/CIRCIMAGING.114.003061. [DOI] [PubMed] [Google Scholar]
- 33.Toulemonde MEG, et al. High frame-rate contrast echocardiography: in-human demonstration. JACC Cardiovasc. Imaging. 2018;11:923–924. doi: 10.1016/j.jcmg.2017.09.011. [DOI] [PubMed] [Google Scholar]
- 34.Stenner P, Schmidt B, Allmendinger T, Flohr T, Kachelriess M. Dynamic iterative beam hardening correction (DIBHC) in myocardial perfusion imaging using contrast-enhanced computed tomography. Invest. Radiol. 2010;45:314–323. doi: 10.1097/RLI.0b013e3181e0300f. [DOI] [PubMed] [Google Scholar]
- 35.Stenner P, et al. Partial scan artifact reduction (PSAR) for the assessment of cardiac perfusion in dynamic phase-correlated CT. Med. Phys. 2009;36:5683–5694. doi: 10.1118/1.3259734. [DOI] [PubMed] [Google Scholar]
- 36.Kitagawa K, George RT, Arbab-Zadeh A, Lima JA, Lardo AC. Characterization and correction of beam-hardening artifacts during dynamic volume CT assessment of myocardial perfusion. Radiology. 2010;256:111–118. doi: 10.1148/radiol.10091399. [DOI] [PubMed] [Google Scholar]
- 37.Hahn J, et al. Motion compensation in the region of the coronary arteries based on partial angle reconstructions from short-scan CT data. Med. Phys. 2017;44:5795–5813. doi: 10.1002/mp.12514. [DOI] [PubMed] [Google Scholar]
- 38.Gotberg M, et al. The evolving future of instantaneous wave-free ratio and fractional flow reserve. J. Am. Coll. Cardiol. 2017;70:1379–1402. doi: 10.1016/j.jacc.2017.07.770. [DOI] [PubMed] [Google Scholar]
- 39.Xaplanteris P, et al. Five-year outcomes with PCI guided by fractional flow reserve. N. Engl. J. Med. 2018;379:250–259. doi: 10.1056/NEJMoa1803538. [DOI] [PubMed] [Google Scholar]
- 40.Danad I, et al. Comparison of coronary CT angiography, SPECT, PET, and hybrid imaging for diagnosis of ischemic heart disease determined by fractional flow reserve. JAMA Cardiol. 2017;2:1100–1107. doi: 10.1001/jamacardio.2017.2471. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 41.Kunze KP, et al. Myocardial perfusion quantification using simultaneously acquired (13) NH3-ammonia PET and dynamic contrast-enhanced MRI in patients at rest and stress. Magn. Reson. Med. 2018;80:2641–2654. doi: 10.1002/mrm.27213. [DOI] [PubMed] [Google Scholar]
- 42.Williams MC, et al. Computed tomography myocardial perfusion vs (15)O-water positron emission tomography and fractional flow reserve. Eur. Radiol. 2017;27:1114–1124. doi: 10.1007/s00330-016-4404-5. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 43.Hoffman JI. The history of the microsphere method for measuring blood flows with special reference to myocardial blood flow: a personal memoir. Am. J. Physiol. Heart Circ. Physiol. 2017;312:H705–H710. doi: 10.1152/ajpheart.00834.2016. [DOI] [PubMed] [Google Scholar]
- 44.Li X, Springer CS, Jr., Jerosch-Herold M. First-pass dynamic contrast-enhanced MRI with extravasating contrast reagent: evidence for human myocardial capillary recruitment in adenosine-induced hyperemia. NMR Biomed. 2009;22:148–157. doi: 10.1002/nbm.1293. [DOI] [PubMed] [Google Scholar]
- 45.Kellman P, et al. Myocardial perfusion cardiovascular magnetic resonance: optimized dual sequence and reconstruction for quantification. J. Cardiovasc. Magn. Reson. 2017;19:43. doi: 10.1186/s12968-017-0355-5. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 46.Tran-Gia J, et al. A model-based reconstruction technique for quantitative myocardial perfusion imaging. Magn. Reson. Med. 2016;76:880–887. doi: 10.1002/mrm.25921. [DOI] [PubMed] [Google Scholar]
- 47.Winant CD, et al. Investigation of dynamic SPECT measurements of the arterial input function in human subjects using simulation, phantom and human studies. Phys. Med. Biol. 2012;57:375–393. doi: 10.1088/0031-9155/57/2/375. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 48.Vasquez AF, Johnson NP, Gould KL. Variation in quantitative myocardial perfusion due to arterial input selection. JACC Cardiovasc. Imaging. 2013;6:559–568. doi: 10.1016/j.jcmg.2012.11.015. [DOI] [PubMed] [Google Scholar]
- 49.Fluckiger JU, Schabel MC, DiBella EV. Toward local arterial input functions in dynamic contrast-enhanced MRI. J. Magn. Reson. Imaging. 2010;32:924–934. doi: 10.1002/jmri.22339. [DOI] [PubMed] [Google Scholar]
- 50.Martens, J., Panzer, J., van den Wijngaard, J. P. H. M., Siebes, M. & Schreiber, L. M. in Functional Imaging and Modelling of the Heart (eds Pop, M., & Wright, G.) 369–380 (Springer, 2017).
- 51.Bindschadler M, Branch KR, Alessio AM. Quantitative myocardial perfusion from static cardiac and dynamic arterial CT. Phys. Med. Biol. 2018;63:105020. doi: 10.1088/1361-6560/aac0bd. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 52.Hachamovitch R. Does ischemia burden in stable coronary artery disease effectively identify revascularization candidates? Ischemia burden in stable coronary artery disease effectively identifies revascularization candidates. Circ. Cardiovasc. Imaging. 2015;8:e000352. doi: 10.1161/CIRCIMAGING.113.000352. [DOI] [PubMed] [Google Scholar]
- 53.Nudi F, et al. Diagnostic accuracy of myocardial perfusion imaging with CZT technology: systemic review and meta-analysis of comparison with invasive coronary angiography. JACC Cardiovasc. Imaging. 2017;10:787–794. doi: 10.1016/j.jcmg.2016.10.023. [DOI] [PubMed] [Google Scholar]
- 54.Wells RG, et al. Dynamic SPECT measurement of absolute myocardial blood flow in a porcine model. J. Nucl. Med. 2014;55:1685–1691. doi: 10.2967/jnumed.114.139782. [DOI] [PubMed] [Google Scholar]
- 55.Wells RG, et al. Optimization of SPECT measurement of myocardial blood flow with corrections for attenuation, motion, and blood binding compared with PET. J. Nucl. Med. 2017;58:2013–2019. doi: 10.2967/jnumed.117.191049. [DOI] [PubMed] [Google Scholar]
- 56.Taqueti VR, et al. Global coronary flow reserve is associated with adverse cardiovascular events independently of luminal angiographic severity and modifies the effect of early revascularization. Circulation. 2015;131:19–27. doi: 10.1161/CIRCULATIONAHA.114.011939. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 57.Taqueti VR, et al. Excess cardiovascular risk in women relative to men referred for coronary angiography is associated with severely impaired coronary flow reserve, not obstructive disease. Circulation. 2017;135:566–577. doi: 10.1161/CIRCULATIONAHA.116.023266. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 58.Hu LH, et al. Upper reference limits of transient ischemic dilation ratio for different protocols on new-generation cadmium zinc telluride cameras: a report from REFINE SPECT registry. J. Nucl. Cardiol. 2019 doi: 10.1007/s12350-019-01730-y. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 59.Bocher M, et al. A fast cardiac gamma camera with dynamic SPECT capabilities: design, system validation and future potential. Eur. J. Nucl. Med. Mol. Imaging. 2010;37:1887–1902. doi: 10.1007/s00259-010-1488-z. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 60.Erlandsson K, Kacperski K, van Gramberg D, Hutton BF. Performance evaluation of D-SPECT: a novel SPECT system for nuclear cardiology. Phys. Med. Biol. 2009;54:2635–2649. doi: 10.1088/0031-9155/54/9/003. [DOI] [PubMed] [Google Scholar]
- 61.Herzog BA, et al. Nuclear myocardial perfusion imaging with a cadmium-zinc-telluride detector technique: optimized protocol for scan time reduction. J. Nucl. Med. 2010;51:46–51. doi: 10.2967/jnumed.109.065532. [DOI] [PubMed] [Google Scholar]
- 62.Sharir T, et al. Multicenter trial of high-speed versus conventional single-photon emission computed tomography imaging: quantitative results of myocardial perfusion and left ventricular function. J. Am. Coll. Cardiol. 2010;55:1965–1974. doi: 10.1016/j.jacc.2010.01.028. [DOI] [PubMed] [Google Scholar]
- 63.Einstein AJ, et al. Comparison of image quality, myocardial perfusion, and left ventricular function between standard imaging and single-injection ultra-low-dose imaging using a high-efficiency SPECT camera: the MILLISIEVERT study. J. Nucl. Med. 2014;55:1430–1437. doi: 10.2967/jnumed.114.138222. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 64.Pazhenkottil AP, et al. Hybrid SPECT perfusion imaging and coronary CT angiography: long-term prognostic value for cardiovascular outcomes. Radiology. 2018;288:694–702. doi: 10.1148/radiol.2018171303. [DOI] [PubMed] [Google Scholar]
- 65.Spier N, et al. Classification of polar maps from cardiac perfusion imaging with graph-convolutional neural networks. Sci. Rep. 2019;9:7569. doi: 10.1038/s41598-019-43951-8. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 66.Yu M, Nekolla SG, Schwaiger M, Robinson SP. The next generation of cardiac positron emission tomography imaging agents: discovery of flurpiridaz F-18 for detection of coronary disease. Semin. Nucl. Med. 2011;41:305–313. doi: 10.1053/j.semnuclmed.2011.02.004. [DOI] [PubMed] [Google Scholar]
- 67.Nordstrom J, et al. Calculation of left ventricular volumes and ejection fraction from dynamic cardiac-gated (15)O-water PET/CT: 5D-PET. EJNMMI Phys. 2017;4:26. doi: 10.1186/s40658-017-0195-2. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 68.Yamamoto Y, et al. A new strategy for the assessment of viable myocardium and regional myocardial blood flow using 15O-water and dynamic positron emission tomography. Circulation. 1992;86:167–178. doi: 10.1161/01.cir.86.1.167. [DOI] [PubMed] [Google Scholar]
- 69.de Haan S, et al. Parametric imaging of myocardial viability using 15O-labelled water and PET/CT: comparison with late gadolinium-enhanced CMR. Eur. J. Nucl. Med. Mol. Imaging. 2012;39:1240–1245. doi: 10.1007/s00259-012-2134-8. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 70.Jaarsma C, et al. Diagnostic performance of noninvasive myocardial perfusion imaging using single-photon emission computed tomography, cardiac magnetic resonance, and positron emission tomography imaging for the detection of obstructive coronary artery disease: a meta-analysis. J. Am. Coll. Cardiol. 2012;59:1719–1728. doi: 10.1016/j.jacc.2011.12.040. [DOI] [PubMed] [Google Scholar]
- 71.Danad I, Raijmakers PG, Knaapen P. Diagnosing coronary artery disease with hybrid PET/CT: it takes two to tango. J. Nucl. Cardiol. 2013;20:874–890. doi: 10.1007/s12350-013-9753-8. [DOI] [PubMed] [Google Scholar]
- 72.Danad I, et al. Diagnostic performance of cardiac imaging methods to diagnose ischaemia-causing coronary artery disease when directly compared with fractional flow reserve as a reference standard: a meta-analysis. Eur. Heart. J. 2017;38:991–998. doi: 10.1093/eurheartj/ehw095. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 73.Takx RA, et al. Diagnostic accuracy of stress myocardial perfusion imaging compared to invasive coronary angiography with fractional flow reserve meta-analysis. Circ. Cardiovasc. Imaging. 2015;8:e002666. doi: 10.1161/CIRCIMAGING.114.002666. [DOI] [PubMed] [Google Scholar]
- 74.Kajander SA, et al. Clinical value of absolute quantification of myocardial perfusion with (15)O-water in coronary artery disease. Circ. Cardiovasc. Imaging. 2011;4:678–684. doi: 10.1161/CIRCIMAGING.110.960732. [DOI] [PubMed] [Google Scholar]
- 75.Hajjiri MM, et al. Comparison of positron emission tomography measurement of adenosine-stimulated absolute myocardial blood flow versus relative myocardial tracer content for physiological assessment of coronary artery stenosis severity and location. JACC Cardiovasc. Imaging. 2009;2:751–758. doi: 10.1016/j.jcmg.2009.04.004. [DOI] [PubMed] [Google Scholar]
- 76.Fiechter M, et al. Diagnostic value of 13N-ammonia myocardial perfusion PET: added value of myocardial flow reserve. J. Nucl. Med. 2012;53:1230–1234. doi: 10.2967/jnumed.111.101840. [DOI] [PubMed] [Google Scholar]
- 77.Danad I, et al. Quantitative assessment of myocardial perfusion in the detection of significant coronary artery disease: cutoff values and diagnostic accuracy of quantitative [15O]H2O PET imaging. J. Am. Coll. Cardiol. 2014;64:1464–1475. doi: 10.1016/j.jacc.2014.05.069. [DOI] [PubMed] [Google Scholar]
- 78.Joutsiniemi E, et al. Absolute flow or myocardial flow reserve for the detection of significant coronary artery disease? Eur. Heart J. Cardiovasc. Imaging. 2014;15:659–665. doi: 10.1093/ehjci/jet274. [DOI] [PubMed] [Google Scholar]
- 79.Shaw LJ, Iskandrian AE. Prognostic value of gated myocardial perfusion SPECT. J. Nucl. Cardiol. 2004;11:171–185. doi: 10.1016/j.nuclcard.2003.12.004. [DOI] [PubMed] [Google Scholar]
- 80.Ziadi MC, et al. Impaired myocardial flow reserve on rubidium-82 positron emission tomography imaging predicts adverse outcomes in patients assessed for myocardial ischemia. J. Am. Coll. Cardiol. 2011;58:740–748. doi: 10.1016/j.jacc.2011.01.065. [DOI] [PubMed] [Google Scholar]
- 81.Herzog BA, et al. Long-term prognostic value of 13N-ammonia myocardial perfusion positron emission tomography added value of coronary flow reserve. J. Am. Coll. Cardiol. 2009;54:150–156. doi: 10.1016/j.jacc.2009.02.069. [DOI] [PubMed] [Google Scholar]
- 82.Farhad H, et al. Added prognostic value of myocardial blood flow quantitation in rubidium-82 positron emission tomography imaging. Eur. Heart. J. Cardiovasc. Imaging. 2013;14:1203–1210. doi: 10.1093/ehjci/jet068. [DOI] [PubMed] [Google Scholar]
- 83.Berman DS, et al. Phase II safety and clinical comparison with single-photon emission computed tomography myocardial perfusion imaging for detection of coronary artery disease: flurpiridaz F 18 positron emission tomography. J. Am. Coll. Cardiol. 2013;61:469–477. doi: 10.1016/j.jacc.2012.11.022. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 84.Petibon Y, Rakvongthai Y, El Fakhri G, Ouyang J. Direct parametric reconstruction in dynamic PET myocardial perfusion imaging: in vivo studies. Phys. Med. Biol. 2017;62:3539–3565. doi: 10.1088/1361-6560/aa6394. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 85.Atkinson DJ, Burstein D, Edelman RR. First-pass cardiac perfusion: evaluation with ultrafast MR imaging. Radiology. 1990;174:757–762. doi: 10.1148/radiology.174.3.2305058. [DOI] [PubMed] [Google Scholar]
- 86.Schwitter J, et al. MR-IMPACT II: Magnetic resonance imaging for myocardial perfusion assessment in coronary artery disease trial: perfusion-cardiac magnetic resonance vs. single-photon emission computed tomography for the detection of coronary artery disease: a comparative multicentre, multivendor trial. Eur. Heart. J. 2013;34:775–781. doi: 10.1093/eurheartj/ehs022. [DOI] [PubMed] [Google Scholar]
- 87.Bingham SE, Hachamovitch R. Incremental prognostic significance of combined cardiac magnetic resonance imaging, adenosine stress perfusion, delayed enhancement, and left ventricular function over preimaging information for the prediction of adverse events. Circulation. 2011;123:1509–1518. doi: 10.1161/CIRCULATIONAHA.109.907659. [DOI] [PubMed] [Google Scholar]
- 88.Sammut EC, et al. Prognostic value of quantitative stress perfusion cardiac magnetic resonance. JACC Cardiovasc. Imaging. 2018;11:686–694. doi: 10.1016/j.jcmg.2017.07.022. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 89.Greenwood JP, et al. Prognostic value of cardiovascular magnetic resonance and single-photon emission computed tomography in suspected coronary heart disease: long-term follow-up of a prospective, diagnostic accuracy cohort study. Ann. Intern. Med. 2016;165:1–9. doi: 10.7326/M15-1801. [DOI] [PubMed] [Google Scholar]
- 90.Heitner JF, et al. Prognostic value of vasodilator stress cardiac magnetic resonance imaging: a multicenter study with 48 000 patient-years of follow-up. JAMA Cardiol. 2019;4:256–264. doi: 10.1001/jamacardio.2019.0035. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 91.Nagel E, et al. Magnetic resonance perfusion or fractional flow reserve in coronary disease. N. Engl. J. Med. 2019;380:2418–2428. doi: 10.1056/NEJMoa1716734. [DOI] [PubMed] [Google Scholar]
- 92.Jerosch-Herold M, Seethamraju RT, Swingen CM, Wilke NM, Stillman AE. Analysis of myocardial perfusion MRI. J. Magn. Reson. Imaging. 2004;19:758–770. doi: 10.1002/jmri.20065. [DOI] [PubMed] [Google Scholar]
- 93.Wilke N, et al. Myocardial perfusion reserve: assessment with multisection, quantitative, first-pass MR imaging. Radiology. 1997;204:373–384. doi: 10.1148/radiology.204.2.9240523. [DOI] [PubMed] [Google Scholar]
- 94.Brown LAE, et al. Fully automated, inline quantification of myocardial blood flow with cardiovascular magnetic resonance: repeatability of measurements in healthy subjects. J. Cardiovasc. Magn. Reson. 2018;20:48. doi: 10.1186/s12968-018-0462-y. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 95.Gatehouse PD, et al. Accurate assessment of the arterial input function during high-dose myocardial perfusion cardiovascular magnetic resonance. J. Magn. Reson. Imaging. 2004;20:39–45. doi: 10.1002/jmri.20054. [DOI] [PubMed] [Google Scholar]
- 96.Wissmann L, Niemann M, Gotschy A, Manka R, Kozerke S. Quantitative three-dimensional myocardial perfusion cardiovascular magnetic resonance with accurate two-dimensional arterial input function assessment. J. Cardiovasc. Magn. Reson. 2015;17:108. doi: 10.1186/s12968-015-0212-3. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 97.Sanchez-Gonzalez J, et al. Optimization of dual-saturation single bolus acquisition for quantitative cardiac perfusion and myocardial blood flow maps. J. Cardiovasc. Magn. Reson. 2015;17:21. doi: 10.1186/s12968-015-0116-2. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 98.Broadbent DA, et al. Myocardial blood flow at rest and stress measured with dynamic contrast-enhanced MRI: comparison of a distributed parameter model with a Fermi function model. Magn. Reson. Med. 2013;70:1591–1597. doi: 10.1002/mrm.24611. [DOI] [PubMed] [Google Scholar]
- 99.Papanastasiou G, et al. Quantitative assessment of myocardial blood flow in coronary artery disease by cardiovascular magnetic resonance: comparison of Fermi and distributed parameter modeling against invasive methods. J. Cardiovasc. Magn. Reson. 2016;18:57. doi: 10.1186/s12968-016-0270-1. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 100.Hsu LY, et al. Diagnostic performance of fully automated pixel-wise quantitative myocardial perfusion imaging by cardiovascular magnetic resonance. JACC Cardiovasc. Imaging. 2018;11:697–707. doi: 10.1016/j.jcmg.2018.01.005. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 101.Jacobs M, Benovoy M, Chang LC, Arai AE, Hsu LY. Evaluation of an automated method for arterial input function detection for first-pass myocardial perfusion cardiovascular magnetic resonance. J. Cardiovasc Magn. Reson. 2016;18:17. doi: 10.1186/s12968-016-0239-0. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 102.Camici PG, d’Amati G, Rimoldi O. Coronary microvascular dysfunction: mechanisms and functional assessment. Nat. Rev. Cardiol. 2015;12:48–62. doi: 10.1038/nrcardio.2014.160. [DOI] [PubMed] [Google Scholar]
- 103.Hautvast GL, et al. Quantitative analysis of transmural gradients in myocardial perfusion magnetic resonance images. Magn. Reson. Med. 2011;66:1477–1487. doi: 10.1002/mrm.22930. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 104.Sammut E, et al. Feasibility of high-resolution quantitative perfusion analysis in patients with heart failure. J. Cardiovasc. Magn. Reson. 2015;17:13. doi: 10.1186/s12968-015-0124-2. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 105.Villa AD, et al. Microvascular ischemia in hypertrophic cardiomyopathy: new insights from high-resolution combined quantification of perfusion and late gadolinium enhancement. J. Cardiovasc. Magn. Reson. 2016;18:4. doi: 10.1186/s12968-016-0223-8. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 106.Liu A, et al. Gadolinium-free cardiac MR stress T1-mapping to distinguish epicardial from microvascular coronary disease. J. Am. Coll. Cardiol. 2018;71:957–968. doi: 10.1016/j.jacc.2017.11.071. [DOI] [PMC free article] [PubMed] [Google Scholar] [Retracted]
- 107.Greenwood JP, et al. Cardiovascular magnetic resonance and single-photon emission computed tomography for diagnosis of coronary heart disease (CE-MARC): a prospective trial. Lancet. 2012;379:453–460. doi: 10.1016/S0140-6736(11)61335-4. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 108.Schwitter J, et al. Superior diagnostic performance of perfusion-cardiovascular magnetic resonance versus SPECT to detect coronary artery disease: the secondary endpoints of the multicenter multivendor MR-IMPACT II (Magnetic Resonance Imaging for Myocardial Perfusion Assessment in Coronary Artery Disease Trial) J. Cardiovasc. Magn. Res. 2012;14:61. doi: 10.1186/1532-429X-14-61. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 109.Biglands JD, et al. Quantitative myocardial perfusion imaging versus visual analysis in diagnosing myocardial ischemia: a CE-MARC substudy. JACC Cardiovasc. Imaging. 2018;11:711–718. doi: 10.1016/j.jcmg.2018.02.019. [DOI] [PubMed] [Google Scholar]
- 110.Greenwood JP, et al. Effect of care guided by cardiovascular magnetic resonance, myocardial perfusion scintigraphy, or NICE guidelines on subsequent unnecessary angiography rates: the CE-MARC 2 randomized clinical trial. JAMA. 2016;316:1051–1060. doi: 10.1001/jama.2016.12680. [DOI] [PubMed] [Google Scholar]
- 111.Morton G, et al. Quantification of absolute myocardial perfusion in patients with coronary artery disease: comparison between cardiovascular magnetic resonance and positron emission tomography. J. Am. Coll. Cardiol. 2012;60:1546–1555. doi: 10.1016/j.jacc.2012.05.052. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 112.Engblom H, et al. Fully quantitative cardiovascular magnetic resonance myocardial perfusion ready for clinical use: a comparison between cardiovascular magnetic resonance imaging and positron emission tomography. J. Cardiovasc. Magn. Reson. 2017;19:78. doi: 10.1186/s12968-017-0388-9. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 113.Nazarian S, et al. Safety of magnetic resonance imaging in patients with cardiac devices. N. Engl. J. Med. 2017;377:2555–2564. doi: 10.1056/NEJMoa1604267. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 114.Benovoy M, et al. Robust universal nonrigid motion correction framework for first-pass cardiac MR perfusion imaging. J. Magn. Reson. Imaging. 2017;46:1060–1072. doi: 10.1002/jmri.25659. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 115.Chiribiri A, et al. Assessment of coronary artery stenosis severity and location: quantitative analysis of transmural perfusion gradients by high-resolution MRI versus FFR. JACC Cardiovasc. Imaging. 2013;6:600–609. doi: 10.1016/j.jcmg.2012.09.019. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 116.Michallek F, Dewey M. Fractal analysis of the ischemic transition region in chronic ischemic heart disease using magnetic resonance imaging. Eur. Radiol. 2017;27:1537–1546. doi: 10.1007/s00330-016-4492-2. [DOI] [PubMed] [Google Scholar]
- 117.Kofler A, Dewey M, Schaeffter T, Wald C, Kolbitsch C. Spatio-temporal deep learning-based undersampling artefact reduction for 2D radial cine MRI with limited training data. IEEE Trans. Med. Imaging. 2019 doi: 10.1109/TMI.2019.2930318. [DOI] [PubMed] [Google Scholar]
- 118.Senior R, et al. Clinical practice of contrast echocardiography: recommendation by the European Association of Cardiovascular Imaging (EACVI) 2017. Eur. Heart J. Cardiovasc. Imaging. 2017;18:1205–1205af. doi: 10.1093/ehjci/jex182. [DOI] [PubMed] [Google Scholar]
- 119.Porter TR, et al. Clinical applications of ultrasonic enhancing agents in echocardiography: 2018 American Society of Echocardiography Guidelines Update. J. Am. Soc. Echocardiogr. 2018;31:241–274. doi: 10.1016/j.echo.2017.11.013. [DOI] [PubMed] [Google Scholar]
- 120.Klibanov AL, et al. Detection of individual microbubbles of ultrasound contrast agents: imaging of free-floating and targeted bubbles. Invest. Radiol. 2004;39:187–195. doi: 10.1097/01.rli.0000115926.96796.75. [DOI] [PubMed] [Google Scholar]
- 121.Wei K, et al. Quantification of myocardial blood flow with ultrasound-induced destruction of microbubbles administered as a constant venous infusion. Circulation. 1998;97:473–483. doi: 10.1161/01.cir.97.5.473. [DOI] [PubMed] [Google Scholar]
- 122.Sabia PJ, Powers ER, Jayaweera AR, Ragosta M, Kaul S. Functional significance of collateral blood flow in patients with recent acute myocardial infarction. A study using myocardial contrast echocardiography. Circulation. 1992;85:2080–2089. doi: 10.1161/01.cir.85.6.2080. [DOI] [PubMed] [Google Scholar]
- 123.Senior R, et al. Myocardial perfusion assessment in patients with medium probability of coronary artery disease and no prior myocardial infarction: comparison of myocardial contrast echocardiography with 99mTc single-photon emission computed tomography. Am. Heart J. 2004;147:1100–1105. doi: 10.1016/j.ahj.2003.12.030. [DOI] [PubMed] [Google Scholar]
- 124.Wei K, et al. Noninvasive quantification of coronary blood flow reserve in humans using myocardial contrast echocardiography. Circulation. 2001;103:2560–2565. doi: 10.1161/01.cir.103.21.2560. [DOI] [PubMed] [Google Scholar]
- 125.Wu J, et al. Comparison of fractional flow reserve assessment with demand stress myocardial contrast echocardiography in angiographically intermediate coronary stenoses. Circ. Cardiovasc. Imaging. 2016;9:e004129. doi: 10.1161/CIRCIMAGING.116.004129. [DOI] [PubMed] [Google Scholar]
- 126.Coggins MP, et al. Noninvasive prediction of ultimate infarct size at the time of acute coronary occlusion based on the extent and magnitude of collateral-derived myocardial blood flow. Circulation. 2001;104:2471–2477. doi: 10.1161/hc4501.098954. [DOI] [PubMed] [Google Scholar]
- 127.Taqui S, et al. Coronary microvascular dysfunction by myocardial contrast echocardiography in nonelderly patients referred for computed tomographic coronary angiography. J. Am. Soc. Echocardiogr. 2019;32:817–825. doi: 10.1016/j.echo.2019.03.001. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 128.Senior R, et al. Comparison of sulfur hexafluoride microbubble (SonoVue)-enhanced myocardial contrast echocardiography with gated single-photon emission computed tomography for detection of significant coronary artery disease: a large European multicenter study. J. Am. Coll. Cardiol. 2013;62:1353–1361. doi: 10.1016/j.jacc.2013.04.082. [DOI] [PubMed] [Google Scholar]
- 129.Porter TR, et al. Patient outcome following 2 different stress imaging approaches: a prospective randomized comparison. J. Am. Coll. Cardiol. 2013;61:2446–2455. doi: 10.1016/j.jacc.2013.04.019. [DOI] [PubMed] [Google Scholar]
- 130.Gaibazzi N, Reverberi C, Lorenzoni V, Molinaro S, Porter TR. Prognostic value of high-dose dipyridamole stress myocardial contrast perfusion echocardiography. Circulation. 2012;126:1217–1224. doi: 10.1161/CIRCULATIONAHA.112.110031. [DOI] [PubMed] [Google Scholar]
- 131.Tong KL, et al. Myocardial contrast echocardiography versus thrombolysis in myocardial infarction score in patients presenting to the emergency department with chest pain and a nondiagnostic electrocardiogram. J. Am. Coll. Cardiol. 2005;46:920–927. doi: 10.1016/j.jacc.2005.03.076. [DOI] [PubMed] [Google Scholar]
- 132.Swinburn JM, Lahiri A, Senior R. Intravenous myocardial contrast echocardiography predicts recovery of dysynergic myocardium early after acute myocardial infarction. J. Am. Coll. Cardiol. 2001;38:19–25. doi: 10.1016/s0735-1097(01)01317-1. [DOI] [PubMed] [Google Scholar]
- 133.Vogel R, et al. The quantification of absolute myocardial perfusion in humans by contrast echocardiography: algorithm and validation. J. Am. Coll. Cardiol. 2005;45:754–762. doi: 10.1016/j.jacc.2004.11.044. [DOI] [PubMed] [Google Scholar]
- 134.Rana O, et al. Acute hypoglycemia decreases myocardial blood flow reserve in patients with type 1 diabetes mellitus and in healthy humans. Circulation. 2011;124:1548–1556. doi: 10.1161/CIRCULATIONAHA.110.992297. [DOI] [PubMed] [Google Scholar]
- 135.Tang MX, et al. Quantitative contrast-enhanced ultrasound imaging: a review of sources of variability. Interface Focus. 2011;1:520–539. doi: 10.1098/rsfs.2011.0026. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 136.Li Y, et al. Fully automatic myocardial segmentation of contrast echocardiography sequence using random forests guided by shape model. IEEE Trans. Med. Imaging. 2018;37:1081–1091. doi: 10.1109/TMI.2017.2747081. [DOI] [PubMed] [Google Scholar]
- 137.Maresca D, et al. Noninvasive imaging of the coronary vasculature using ultrafast ultrasound. JACC Cardiovasc. Imaging. 2018;11:798–808. doi: 10.1016/j.jcmg.2017.05.021. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 138.Rajpoot K, Grau V, Noble JA, Szmigielski C, Becher H. Multiview fusion 3-D echocardiography: improving the information and quality of real-time 3-D echocardiography. Ultrasound Med. Biol. 2011;37:1056–1072. doi: 10.1016/j.ultrasmedbio.2011.04.018. [DOI] [PubMed] [Google Scholar]
- 139.Gaemperli O, et al. Functionally relevant coronary artery disease: comparison of 64-section CT angiography with myocardial perfusion SPECT. Radiology. 2008;248:414–423. doi: 10.1148/radiol.2482071307. [DOI] [PubMed] [Google Scholar]
- 140.Feger S, et al. Temporal averaging for analysis of four-dimensional whole-heart computed tomography perfusion of the myocardium: proof-of-concept study. Int. J. Cardiovasc. Imaging. 2017;33:371–382. doi: 10.1007/s10554-016-1011-0. [DOI] [PubMed] [Google Scholar]
- 141.Celeng C, et al. Anatomical and functional computed tomography for diagnosing hemodynamically significant coronary artery disease: a meta-analysis. JACC Cardiovasc. Imaging. 2019;12:1316–1325. doi: 10.1016/j.jcmg.2018.07.022. [DOI] [PubMed] [Google Scholar]
- 142.Rossi A, et al. Dynamic computed tomography myocardial perfusion imaging: comparison of clinical analysis methods for the detection of vessel-specific ischemia. Circ. Cardiovasc. Imaging. 2017;10:e005505. doi: 10.1161/CIRCIMAGING.116.005505. [DOI] [PubMed] [Google Scholar]
- 143.Schwarz F, et al. Myocardial CT perfusion imaging in a large animal model: comparison of dynamic versus single-phase acquisitions. JACC Cardiovasc. Imaging. 2013;6:1229–1238. doi: 10.1016/j.jcmg.2013.05.018. [DOI] [PubMed] [Google Scholar]
- 144.Ostovaneh MR, et al. Diagnostic accuracy of semi-automatic quantitative metrics as an alternative to expert reading of CT myocardial perfusion in the CORE320 study. J. Cardiovasc. Comput. Tomogr. 2018;12:212–219. doi: 10.1016/j.jcct.2018.03.010. [DOI] [PubMed] [Google Scholar]
- 145.Nakauchi Y, et al. Quantitative myocardial perfusion analysis using multi-row detector CT in acute myocardial infarction. Heart. 2012;98:566–572. doi: 10.1136/heartjnl-2011-300915. [DOI] [PubMed] [Google Scholar]
- 146.Kuhl JT, et al. Endocardial-epicardial distribution of myocardial perfusion reserve assessed by multidetector computed tomography in symptomatic patients without significant coronary artery disease: insights from the CORE320 multicentre study. Eur. Heart J. Cardiovasc. Imaging. 2016;17:779–787. doi: 10.1093/ehjci/jev206. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 147.Rossi A, et al. Stress myocardial perfusion: imaging with multidetector CT. Radiology. 2014;270:25–46. doi: 10.1148/radiol.13112739. [DOI] [PubMed] [Google Scholar]
- 148.Kitagawa, K., Erglis, A. & Dewey, M. in Cardiac CT (ed Dewey M.) 303–326 (Springer, 2014).
- 149.Rief M, et al. Computed tomography angiography and myocardial computed tomography perfusion in patients with coronary stents: prospective intraindividual comparison with conventional coronary angiography. J. Am. Coll. Cardiol. 2013;62:1476–1485. doi: 10.1016/j.jacc.2013.03.088. [DOI] [PubMed] [Google Scholar]
- 150.Patel MR, et al. Prevalence and predictors of nonobstructive coronary artery disease identified with coronary angiography in contemporary clinical practice. Am. Heart J. 2014;167:846–852. doi: 10.1016/j.ahj.2014.03.001. [DOI] [PubMed] [Google Scholar]
- 151.Patel MR, et al. Low diagnostic yield of elective coronary angiography. N. Engl. J. Med. 2010;362:886–895. doi: 10.1056/NEJMoa0907272. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 152.Taylor CA, Fonte TA, Min JK. Computational fluid dynamics applied to cardiac computed tomography for noninvasive quantification of fractional flow reserve: scientific basis. J. Am. Coll. Cardiol. 2013;61:2233–2241. doi: 10.1016/j.jacc.2012.11.083. [DOI] [PubMed] [Google Scholar]
- 153.Itu L, et al. A machine-learning approach for computation of fractional flow reserve from coronary computed tomography. J. Appl. Physiol. 2016;121:42–52. doi: 10.1152/japplphysiol.00752.2015. [DOI] [PubMed] [Google Scholar]
- 154.Rochitte CE, et al. Computed tomography angiography and perfusion to assess coronary artery stenosis causing perfusion defects by single photon emission computed tomography: the CORE320 study. Eur. Heart J. 2014;35:1120–1130. doi: 10.1093/eurheartj/eht488. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 155.Sorgaard MH, et al. Diagnostic accuracy of static CT perfusion for the detection of myocardial ischemia. A systematic review and meta-analysis. J. Cardiovasc. Comput. Tomogr. 2016;10:450–457. doi: 10.1016/j.jcct.2016.09.003. [DOI] [PubMed] [Google Scholar]
- 156.Coenen A, et al. Integrating CT myocardial perfusion and CT-FFR in the work-up of coronary artery disease. JACC Cardiovasc. Imaging. 2017;10:760–770. doi: 10.1016/j.jcmg.2016.09.028. [DOI] [PubMed] [Google Scholar]
- 157.Hecht HS, Narula J, Fearon WF. Fractional flow reserve and coronary computed tomographic angiography: a review and critical analysis. Circ. Res. 2016;119:300–316. doi: 10.1161/CIRCRESAHA.116.307914. [DOI] [PubMed] [Google Scholar]
- 158.Sorgaard MH, et al. Value of myocardial perfusion assessment with coronary computed tomography angiography in patients with recent acute-onset chest pain. JACC Cardiovasc. Imaging. 2018;11:1611–1621. doi: 10.1016/j.jcmg.2017.09.022. [DOI] [PubMed] [Google Scholar]
- 159.Lubbers M, et al. Comprehensive cardiac CT with myocardial perfusion imaging versus functional testing in suspected coronary artery disease: the multicenter, randomized CRESCENT-II trial. JACC Cardiovasc. Imaging. 2018;11:1625–1636. doi: 10.1016/j.jcmg.2017.10.010. [DOI] [PubMed] [Google Scholar]
- 160.Rief M, et al. Coronary artery disease: analysis of diagnostic performance of CT perfusion and MR perfusion imaging in comparison with quantitative coronary angiography and SPECT-multicenter prospective trial. Radiology. 2018;286:461–470. doi: 10.1148/radiol.2017162447. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 161.Chen MY, et al. Prognostic value of combined CT angiography and myocardial perfusion imaging versus invasive coronary angiography and nuclear stress perfusion imaging in the prediction of major adverse cardiovascular events: the CORE320 multicenter study. Radiology. 2017;284:55–65. doi: 10.1148/radiol.2017161565. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 162.Nakamura S, et al. Incremental prognostic value of myocardial blood flow quantified with stress dynamic computed tomography perfusion imaging. JACC Cardiovasc. Imaging. 2019;12:1379–1387. doi: 10.1016/j.jcmg.2018.05.021. [DOI] [PubMed] [Google Scholar]
- 163.Ishida M, et al. Underestimation of myocardial blood flow by dynamic perfusion CT: explanations by two-compartment model analysis and limited temporal sampling of dynamic CT. J. Cardiovasc. Comput. Tomogr. 2016;10:207–214. doi: 10.1016/j.jcct.2016.01.008. [DOI] [PubMed] [Google Scholar]
- 164.Alessio AM, et al. Accuracy of myocardial blood flow estimation from dynamic contrast-enhanced cardiac CT compared with PET. Circ. Cardiovasc. Imaging. 2019;12:e008323. doi: 10.1161/CIRCIMAGING.118.008323. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 165.Goto Y, et al. Diagnostic accuracy of endocardial-to-epicardial myocardial blood flow ratio for the detection of significant coronary artery disease with dynamic myocardial perfusion dual-source computed tomography. Circ. J. 2017;81:1477–1483. doi: 10.1253/circj.CJ-16-1319. [DOI] [PubMed] [Google Scholar]
- 166.Fujita M, et al. Dose reduction in dynamic CT stress myocardial perfusion imaging: comparison of 80-kV/370-mAs and 100-kV/300-mAs protocols. Eur. Radiol. 2014;24:748–755. doi: 10.1007/s00330-013-3063-z. [DOI] [PubMed] [Google Scholar]
- 167.Gutjahr R, et al. Human imaging with photon counting-based computed tomography at clinical dose levels: contrast-to-noise ratio and cadaver studies. Invest. Radiol. 2016;51:421–429. doi: 10.1097/RLI.0000000000000251. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 168.Kachelriess M. Iterative reconstruction techniques: what do they mean for cardiac CT? Curr. Cardiovasc. Imaging Rep. 2013;6:268–281. [Google Scholar]
- 169.Lukas S, Feger S, Rief M, Zimmermann E, Dewey M. Noise reduction and motion elimination in low-dose 4D myocardial computed tomography perfusion (CTP): preliminary clinical evaluation of the ASTRA4D algorithm. Eur. Radiol. 2019;29:4572–4582. doi: 10.1007/s00330-018-5899-8. [DOI] [PubMed] [Google Scholar]
- 170.Chen H, et al. Low-dose CT via convolutional neural network. Biomed. Opt. Express. 2017;8:679–694. doi: 10.1364/BOE.8.000679. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 171.Zhu B, Liu JZ, Cauley SF, Rosen BR, Rosen MS. Image reconstruction by domain-transform manifold learning. Nature. 2018;555:487–492. doi: 10.1038/nature25988. [DOI] [PubMed] [Google Scholar]
- 172.Maier, J., Berker, Y., Sawall, S. & Kachelriess, M. in Proc. SPIE 10573, Medical Imaging 2018: Physics of Medical Imaging 105731L (2018).
- 173.Maurovich-Horvat P, Ferencik M, Voros S, Merkely B, Hoffmann U. Comprehensive plaque assessment by coronary CT angiography. Nat. Rev. Cardiol. 2014;11:390–402. doi: 10.1038/nrcardio.2014.60. [DOI] [PubMed] [Google Scholar]
- 174.Fearon WF, et al. Clinical outcomes and cost-effectiveness of fractional flow reserve-guided percutaneous coronary intervention in patients with stable coronary artery disease: three-year follow-up of the FAME 2 trial (Fractional Flow Reserve Versus Angiography for Multivessel Evaluation) Circulation. 2018;137:480–487. doi: 10.1161/CIRCULATIONAHA.117.031907. [DOI] [PubMed] [Google Scholar]
- 175.van de Hoef TP, et al. Fractional flow reserve as a surrogate for inducible myocardial ischaemia. Nat. Rev. Cardiol. 2013;10:439–452. doi: 10.1038/nrcardio.2013.86. [DOI] [PubMed] [Google Scholar]
- 176.van Nunen LX, et al. Fractional flow reserve versus angiography for guidance of PCI in patients with multivessel coronary artery disease (FAME): 5-year follow-up of a randomised controlled trial. Lancet. 2015;386:1853–1860. doi: 10.1016/S0140-6736(15)00057-4. [DOI] [PubMed] [Google Scholar]
- 177.Sen S, et al. Development and validation of a new adenosine-independent index of stenosis severity from coronary wave-intensity analysis: results of the ADVISE (ADenosine Vasodilator Independent Stenosis Evaluation) study. J. Am. Coll. Cardiol. 2012;59:1392–1402. doi: 10.1016/j.jacc.2011.11.003. [DOI] [PubMed] [Google Scholar]
- 178.Davies JE, et al. Use of the instantaneous wave-free ratio or fractional flow reserve in PCI. N. Engl. J. Med. 2017;376:1824–1834. doi: 10.1056/NEJMoa1700445. [DOI] [PubMed] [Google Scholar]
- 179.Gotberg M, et al. Instantaneous wave-free ratio versus fractional flow reserve to guide PCI. N. Engl. J. Med. 2017;376:1813–1823. doi: 10.1056/NEJMoa1616540. [DOI] [PubMed] [Google Scholar]
- 180.van de Hoef TP, Siebes M, Spaan JA, Piek JJ. Fundamentals in clinical coronary physiology: why coronary flow is more important than coronary pressure. Eur. Heart J. 2015;36:3312–3319. doi: 10.1093/eurheartj/ehv235. [DOI] [PubMed] [Google Scholar]
- 181.Seiler C, Fleisch M, Garachemani A, Meier B. Coronary collateral quantitation in patients with coronary artery disease using intravascular flow velocity or pressure measurements. J. Am. Coll. Cardiol. 1998;32:1272–1279. doi: 10.1016/s0735-1097(98)00384-2. [DOI] [PubMed] [Google Scholar]
- 182.Echavarría-Pinto M, et al. Diagnostic accuracy of baseline distal-to-aortic pressure ratio to assess coronary stenosis severity: a post-hoc analysis of the ADVISE II study. JACC Cardiovasc. Interv. 2015;8:834–836. doi: 10.1016/j.jcin.2014.12.245. [DOI] [PubMed] [Google Scholar]
- 183.US National Library of Medicine. ClinicalTrials.govhttps://www.clinicaltrials.gov/ct2/show/NCT02328820 (2019).
- 184.Cho H, et al. Angiography-based machine learning for predicting fractional flow reserve in intermediate coronary artery lesions. J. Am. Heart Assoc. 2019;8:e011685. doi: 10.1161/JAHA.118.011685. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 185.Sommer K, et al. Resting myocardial blood flow quantification using contrast-enhanced magnetic resonance imaging in the presence of stenosis: a computational fluid dynamics study. Med. Phys. 2015;42:4375–4384. doi: 10.1118/1.4922708. [DOI] [PubMed] [Google Scholar]
- 186.Schonenberger E, et al. Patient acceptance of noninvasive and invasive coronary angiography. PLoS One. 2007;2:e246. doi: 10.1371/journal.pone.0000246. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 187.Feger S, et al. Patient satisfaction with coronary CT angiography, myocardial CT perfusion, myocardial perfusion MRI, SPECT myocardial perfusion imaging and conventional coronary angiography. Eur. Radiol. 2015;25:2115–2124. doi: 10.1007/s00330-015-3604-8. [DOI] [PubMed] [Google Scholar]
- 188.Minhas A, et al. Patient preferences for coronary CT angiography with stress perfusion, SPECT, or invasive coronary angiography. Radiology. 2019;291:340–348. doi: 10.1148/radiol.2019181409. [DOI] [PubMed] [Google Scholar]
- 189.Muzik O, et al. Validation of nitrogen-13-ammonia tracer kinetic model for quantification of myocardial blood flow using PET. J. Nucl. Med. 1993;34:83–91. [PubMed] [Google Scholar]
- 190.Wu HM, et al. Quantification of myocardial blood flow using dynamic nitrogen-13-ammonia PET studies and factor analysis of dynamic structures. J. Nucl. Med. 1995;36:2087–2093. [PubMed] [Google Scholar]
- 191.Glover DK, et al. Comparison between 201Tl and 99mTc sestamibi uptake during adenosine-induced vasodilation as a function of coronary stenosis severity. Circulation. 1995;91:813–820. doi: 10.1161/01.cir.91.3.813. [DOI] [PubMed] [Google Scholar]
- 192.Kero T, et al. Evaluation of quantitative CMR perfusion imaging by comparison with simultaneous 15O-water-PET. J. Nucl. Cardiol. 2019 doi: 10.1007/s12350-019-01810-z. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 193.van de Hoef TP, et al. Physiological basis and long-term clinical outcome of discordance between fractional flow reserve and coronary flow velocity reserve in coronary stenoses of intermediate severity. Circ. Cardiovasc. Interv. 2014;7:301–311. doi: 10.1161/CIRCINTERVENTIONS.113.001049. [DOI] [PubMed] [Google Scholar]
Associated Data
This section collects any data citations, data availability statements, or supplementary materials included in this article.