Abstract
Regenerative tissue-engineered matrix-based heart valves (TEM-based TEHVs) may become an alternative to currently-used bioprostheses for transcatheter valve replacement. We recently identified TEM-based TEHVs-geometry as one key-factor guiding their remodeling towards successful long-term performance or failure. While our first-generation TEHVs, with a simple, non-physiological valve-geometry, failed over time due to leaflet-wall fusion phenomena, our second-generation TEHVs, with a computational modeling-inspired design, showed native-like remodeling resulting in long-term performance. However, a thorough understanding on how TEHV-geometry impacts the underlying host cell response, which in return determines tissue remodeling, is not yet fully understood. To assess that, we here present a comparative samples evaluation derived from our first- and second-generation TEHVs. We performed an in-depth qualitative and quantitative (immuno-)histological analysis focusing on key-players of the inflammatory and remodeling cascades (M1/M2 macrophages, α-SMA+- and endothelial cells). First-generation TEHVs were prone to chronic inflammation, showing a high presence of macrophages and α-SMA+-cells, hinge-area thickening, and delayed endothelialization. Second-generation TEHVs presented with negligible amounts of macrophages and α-SMA+-cells, absence of hinge-area thickening, and early endothelialization. Our results suggest that TEHV-geometry can significantly influence the host cell response by determining the infiltration and presence of macrophages and α-SMA+-cells, which play a crucial role in orchestrating TEHV remodeling.
Subject terms: Biotechnology, Tissue engineering, Cardiovascular diseases, Valvular disease
Introduction
Current transcatheter bioprosthetic heart valve replacements are based on glutaraldehyde-fixed animal-derived materials and are therefore associated with long-term structural degradation and limited durability1. Additionally, such bioprostheses are associated with major limitations (i.e. risk for infection and thrombosis) as they lack the fundamental properties of native tissues such a native-like remodeling potential, and importantly also the capacity for growth1.
Heart valve tissue engineering approaches aim at the creation of biological substitutes capable of integration, native-like remodeling, and growth2,3. In this context, acellular tissue-engineered heart valves (TEHVs) for in-situ regeneration are particularly interesting due to their off-the-shelf availability and scalability compared to classical autologous tissue-engineered substitutes2–5. Notably, acellular TEHVs based on decellularized in-vitro-grown tissue-engineered matrices (TEM) showed promising results as pulmonary valve replacements in a translational animal model using transcatheter implantation techniques6,7.
Initially we manufactured our TEM-based TEHVs using a simple, non-physiological valve geometry (to which we refer to as first-generation TEHVs in this manuscript; Fig. 1A–C) for transcatheter pulmonary valve replacement (TPVR) in a preclinical sheep model6. Despite the promising valve performance in the first week after implantation, such first-generation TEHVs showed progressive valvular insufficiency caused by leaflet-wall fusion phenomena and leaflet shortening over time6. Therefore, we recently used a computational modeling (in-silico) approach to achieve an analytical physiological-like design, to which we refer to as second-generation TEM-based TEHV (Fig. 1D–F)7. Such TEHVs comprise an optimized strain distribution profile within the leaflets, in order to prevent tissue compaction and endure functional remodeling, thereby enabling long-term performance7. Second-generation TEHVs were manufactured using the same tissue culture processes as for our first-generation TEHVs, including the same cell source (ovine myofibroblasts), scaffold composite (polyglycolic acid coated with poly-4-hydroxy butyrate), and bioreactor technology6,7.
Remarkably, after TPVR in sheep, second-generation TEHVs demonstrated clinical-grade and preserved long-term performance with the absence of relevant regurgitation and only minimal leaflet shortening, as predicted by the computational models7. While both generations of TEM-based valves showed profound and continuous remodeling potential over time, comprising host cellular infiltration, neo-matrix deposition, and endothelialization, first-generation TEHVs presented with maladaptive remodeling phenomena (i.e. leaflet shortening and thickening) starting several weeks post-implantation. To the contrary, second-generation, computational modeling-inspired TEHVs, exhibited tissue remodeling towards native-like configurations.
So far, previous studies have identified two important parameters that are relevant in the remodeling process of TEHVs. First, the geometry7,8, which influences the stress and strain distribution in the leaflets thereby determining long-term valve functionality. Second, the presence and distribution of α-smooth muscle actin positive (α-SMA+) cells within the valves9, which if over-expressed in the leaflets, induce leaflet retraction, leading to dysfunction and ultimate valve failure9. However, despite the identification of these predictors, the impact and role of inflammatory cells in the remodeling processes, that determines failure6 or success7 of the implanted TEM-based TEHVs is not yet fully understood. Hence, the in-depth understanding of the underlying inflammatory processes, especially during the early stages of the remodeling process, are mandatory to determine and guide the outcome thereby enabling safe clinical translation of TEM-based TEHVs.
Inflammatory host cells such as monocyte-derived naïve macrophages can polarize in response to the local mechanical and biochemical environmental stimuli and/or implanted biomaterial, and can differentiate into a variety of cells that have specific biological functions10. The extreme ends of this polarization range are referred to as the pro-inflammatory macrophage 1 (M1) and the anti-inflammatory macrophage 2 (M2) type11. While M1 macrophages are typically present during an inflammatory phase, M2 cells are primarily active during reparative and constructive remodeling11.
Macrophages play a pivotal role in the initiation and perpetuation of inflammation and remodeling processes, thereby determining either the chronicity or the resolution of the inflammatory process—and this has been demonstrated also for tissue-engineered implants such as vascular grafts12–18. In these studies, M2 macrophages were shown to help the recruitment of tissue remodeling cells (e.g.: smooth muscle cells, endothelial cells (ECs), and other immune cells) by expressing anti-inflammatory cytokines, finally leading to adaptive and functional remodeling13,19–23. To the contrary, the constant presence of the M1 phenotype, which gives rise to a chronic inflammation and scar tissue formation, will finally result into a negative or maladaptive remodeling11.
In this study, we assessed the role and impact of inflammatory host cells on the (mal)-adaptive remodeling processes observed in the hinge area of TEM-based TEHVs. To achieve this, we performed an independent, in-depth qualitative and quantitative (immuno-)histological analysis in tissue samples derived from the hinge area of our previous first-6 and second-generation7 TEHV preclinical studies (Fig. 1). We analyzed key cellular players of the inflammatory and remodeling cascades such as M1 and M2 macrophages, α-SMA+ cells, and ECs. We focused our analysis on the hinge region of the TEHVs as this area is exposed to a maximum degree of mechanical strain24, which is known to be a strong regulator of valvular cell behavior and differentiation25,that in turn strongly influences the (mal)adaptive remodeling phenomena in TEHVs.
Results
First-generation TEHV analyses
Qualitative evaluation of inflammatory host cell infiltration
H&E and MG staining showed abundant cell infiltration over time throughout the valve (Fig. 2 and Supplementary Fig. 1). In the explanted TEHVs from the acute animals, no cellular infiltration within the valve tissue was visible (Fig. 2 A,E,I); the only cells detected were those trapped in the fibrin thrombus (Fig. 2I, star symbol), i.e. erythrocytes (Fig. 2I, triangle) and leukocytes (Fig. 2I, arrow). At 8 weeks, cells were predominantly present in the wall and hinge regions of the valve (Fig. 2B,F). In addition, our analysis revealed a progressive colonization of cells in the hinge region (at 16 and 24 weeks), which further develop towards the leaflets (Fig. 2C,G,D,H). The analysis of the area surrounding the scaffold remnants in the hinge region showed the presence of fibrous tissue of heterogeneous thickness, with eosinophilic cells containing a multilobed nucleus (Fig. 2J, white arrow), multifocal ordered macrophages containing blue granules in the cytoplasm (Fig. 2J,L, arrow head), multinucleated giant cells (Fig. 2L, cross symbol), and isolated lymphocytes (small spherical nucleus with abundant dark staining) forming lymph follicles (Fig. 2J–L), all indicators of an ongoing chronic inflammatory response of the host towards the implanted TEHV and signs of incomplete polymer degradation at 24 weeks. Over time, α-SMA expression decreased in the wall region and gradually increased towards the hinge region and the leaflet (Fig. 2M–P). Abundant infiltration of CD3+ T lymphocytes was observed at the 8 weeks follow-up (Fig. 2R). After 16 (Fig. 2S) and 24 weeks (Fig. 2T), lymphocytes distribution changed from random distribution to multifocal, with clusters detected around polymer leftovers or in follicles. Presence of endogenous ECs was demonstrated via SEM and immunohistochemistry for CD31 and VWF (Supplementary Fig. 2) and was in line with the previously reported results for our first-generation TEHVs6. Interestingly, at 8 weeks inhomogeneous EC coverage was observed via SEM, CD31 and VWF staining (Supplementary Fig. 2A–E). In addition, we observed a large number of platelets (VWF+) entrapped in the pannus (Supplementary Fig. 2B). At later time-points (16 and 24 weeks), the valves demonstrated a confluent, homogenous and persistent spindle-shaped EC layer covering the entire surface (Supplementary Fig. 2F–O) as also confirmed by the immunohistochemistry for CD31 and VWF (Supplementary Fig. 2F–G and K–L). Importantly, the CD31+ ECs in the 16 weeks explants expressed the pro-thrombotic factor vWF (Supplementary Fig. 2G). Cutting artefacts may have prevented the complete depiction of ECs and platelets presence at 24 weeks for the CD31 and vWF stainings (Supplementary Fig. 2K–L), while ECs confluency could be confirmed by SEM imaging (Supplementary Fig. 2M–O).
Quantitative evaluation of macrophages in TEHV hinge area
Contrarily to what is observed for the control wall of TEHVs, the amount of cell infiltration in the hinge region, measured by cell nuclei quantification with DAPI-staining, did not gradually decreased over time (Fig. 3A–D). The number of stained M1 slightly decreased over time, whereas M2 macrophages dramatically increased beyond 8 weeks approaching the total number of M1 at 24 weeks. However, an overall prevalence of the M1 over the M2 phenotype is observed (Fig. 3E), suggesting an ongoing chronic inflammatory response in the hinge area of the TEHVs.
Morphological evaluation
Morphological changes of the TEHV in terms of leaflet length and hinge thickness were evaluated for all available time points (Table 1). Compared to the leaflet length in the acute animals (controls) (Fig. 4A, black column), leaflets showed an initial shortening of 19% at the 8-weeks time point (Fig. 4A, grey bar) which then further progressed over time to a total shortening of approximately 70% at 24-weeks time point (Fig. 4A, white bar), which led to TEHVs functional failure. The hinge thickness increased over time with a total thickening of 66.5% at 24 weeks in-vivo when compared to the hinge thickness in the acute animals (controls) (Fig. 4B).
Table 1.
Geometry | Follow-up | |||||
---|---|---|---|---|---|---|
Acute (= control) | 8 weeks | 16 weeks | 24 weeks | 52 weeks (= 1 year) | Total | |
First-generation | n = 2 | n = 2 | n = 4 | n = 4 | n.a | 12 |
Second-generation | n = 2* | n = 3* | n.a | n.a | n = 3 | 8 |
Second-generation TEHV analysis
Qualitative evaluation of inflammatory host cell infiltration
H&E and MG staining showed few and sparse infiltrated cells in the hinge region at any time point considered (Fig. 5 and Supplementary Fig. 3). In the acute explant, few cells were detected in the fibrin clot (Fig. 5A,D,G): erythrocytes (Fig. 5G, triangle) and leukocytes (Fig. 5G, arrow). After 8 weeks in-vivo, cells were predominantly present in the wall regions of the valve, close to the native tissues (Fig. 5B,E). At 52 weeks follow-up, instead, cells were homogenously distributed in the different valve regions, with some cellular aggregates in the proximity of the few polymeric scaffold remnants (Fig. 5C,F). Cells expressing α-SMA were only detected in the wall area of the valve, suggesting the presence of a functional vascular wall. Independently of the time point considered, few to none α-SMA+ cells were detected in the hinge and leaflet region (Fig. 5J–L). In second-generation TEHVs, CD3+ T lymphocytes were overall less abundant compared to first-generation valves (Fig. 5M–O). Most of the CD3+ T lymphocytes were detected 8 weeks after implantation, accumulated in the pannus at the hinge area (Fig. 5N). After 52 weeks, only sporadic CD3+ cells were detected (Fig. 5O). Finally and in line with our previously reported results7, second-generation TEHVs were covered by a confluent EC layer already after 8 weeks, as shown by SEM imaging and immunohistochemistry (Supplementary Fig. 2). Most importantly, the confluent endothelium was retained up to 52 weeks.
Quantitative evaluation of macrophages in TEHV hinge area
Quantification of the cell nuclei stained with DAPI (Fig. 6A–B) revealed a low number of cells in the hinge region at both 8 weeks and 52 weeks, values comparable to those of the wall region of the valve (Fig. 6C). Overall, a minor presence of macrophages, with a prevalence of M1 over M2 subpopulation (Fig. 6D) was observed, suggesting a generally negligible inflammation of the hinge area.
Morphological evaluation
Comparable to what was reported for first-generation THEVs, second-generation TEHVs displayed an initial 23% shortening of the leaflet length at 8 weeks. However, and in contrast to the first-generation, the shortening did not progress over time suggesting that an equilibrium of leaflet length was achieved in the 52 weeks tissue samples (Fig. 7A, Supplementary Table 2), which is an important parameter to ensure long-term valve performance7. In addition, the hinge region (Fig. 7B) showed a 52% increase of thickness at 8 weeks, which however normalized to the initial control values of the acute explants after 52 weeks (Fig. 7B, Supplementary Table 2).
Discussion
Inflammation is an inescapable process, which naturally follows implantation of any device. Tissue-engineered implants designed for in-situ approaches aim at inducing a controlled inflammatory response to ultimately enable orchestrated healing and remodeling cascades26. Indeed, the impact of host cells on the ongoing inflammatory response and remodeling process changes over time and strongly depends on the type of implanted biomaterial, its geometry, and also on the overall hemodynamic conditions to which it is subjected25,27–30.
In this study, we investigated the inflammatory host cell response in two different generations of TEM-based TEHV explants, which have been previously implanted as pulmonary valve replacements in a translational sheep model6,7. To better understand that, we performed an independent, in-depth qualitative and quantitative (immuno-)histological tissue analysis focusing on the key cellular players of the inflammatory and remodeling processes comprising M1 and M2 macrophages, α-SMA+ cells, lymphocytes, and ECs. In agreement with previously published studies6,7, we report the active role of inflammatory and immune cells in both the regenerative and the maladaptive remodeling of TEM-based TEHVs. Our results indicate that for first-generation TEHVs, the abundance of macrophages in the hinge area is associated with a considerable number of lymphocytes and α-SMA+ cells and resulting tissue fibrosis. To the contrary, the physiological-like geometry of second-generation TEHVs resulted in a milder inflammation with a reduced presence of macrophages, lymphocytes, and α-SMA+ cells. These results highlight how a milder inflammatory response (represented by a limited number of macrophages, lymphocytes, and α-SMA+ cells in the tissue) resulting from a more physiological-like geometry might elicit an adaptive remodeling of the implanted TEM-based TEHV. On the other hand, a strong inflammatory response with abundance of macrophages, as observed for the simplified first-generation TEHV geometry, can cause a maladaptive tissue remodeling, with leaflet thickening and shortening. Our main findings have been summarized in Fig. 8, where we highlight the differences in valve performance, in leaflet remodeling and, importantly, in the presence of M1 and M2 macrophages, α-SMA+ cells, and ECs in first- or second-generation TEHVs depending on the adopted geometry.
Maladaptive remodeling of first-generation TEHVs
α-SMA+ cells have been repeatedly reported as a key cell type involved in leaflet shortening and retraction of TEHVs8,31,32, however their exact role has never been fully elucidated so far. In this study, we have identified two potential regulators that may play an important role in the infiltration and/or differentiation of α-SMA+ cells in the hinge area of our first-generation TEHVs: macrophages and ECs.
In first-generation valves, the chronic inflammatory response was confirmed by a general abundance of M1 over M2 macrophages, and an overall greater number of macrophages and lymphocytes when compared to second-generation TEHVs. The ongoing chronic inflammation may be explained by the presence of polymeric scaffold remnants until the 24 weeks follow-up, that are characterized by surrounding fibrous tissue, eosinophils, macrophages, multinucleated giant cells and lymphocytes (Fig. 2), thus impacting on the degree of inflammation of the host towards the implant.
Macrophages are known to actively impact on the degree and severity of damage and fibrosis by recruiting α-SMA+ cells to the inflammation site33, and by the transition from macrophages to myofibroblasts34. Macrophages are responsible for the release of pro-inflammatory cytokines and metalloproteinases that enhance the inflammatory response and influence the in-vivo wound healing by contributing to myofibroblasts proliferation and recruitment35. Briefly, in response to a tissue injury, macrophages first express the pro-inflammatory M1 phenotype, releasing TNF-α, IL-1β, IL-12, and IL-23. Subsequently, M2 macrophages take over by secreting IL-10 and TGF-β to reduce the inflammation36. During this process, macrophages express a complex phenotype, where cell polarization changes from M1 to M2 over time37, thereby actively regulating fibrotic tissue formation and wound healing38. In the presented study, we observed a steady presence of M1 macrophages, associated to an increase in M2 macrophages over time in first-generation TEHVs. Interestingly, M2 macrophages have been repeatedly reported to also influence fibrosis, by undergoing macrophage-to-myofibroblast transition34, by promoting the fibrogenic activities of fibroblasts39, and by inducing α-SMA expression in fibroblasts40. In addition, in-vitro experiments co-culturing macrophages and α-SMA+ cells demonstrated reduced apoptotic rates for both cell types, suggesting a beneficial interaction which promotes mutual survival41.
The strong inflammatory response and the presence of α-SMA+ cells observed in first-generation TEHVs can be associated to the high strain profile exerted on the matrix as well as to the incomplete endothelialization at the earliest time points. Physiologically, changes in mechanical milieu can influence cell differentiation mechanisms, matrix remodeling, and the endothelialization process, and are often correlated to valvular pathologies25. Native valvular ECs are indeed responsible for the anti-thrombogenic properties, as well as for the retention of the quiescent state of valvular interstitial cells42,43. We may therefore hypothesize that the lack of ECs has caused the activation of the infiltrated interstitial cells towards contractile α-SMA+ cells during the early stages of TEHV remodeling42,44–46. In line with our (immuno-)histological findings, we also observed leaflet shortening, hinge area thickening, and wall-leaflet fusion phenomena of first-generation TEHVs. These adverse remodeling events were assumed to be mainly triggered by the presence of contractile αSMA+ cells and may be a consequence of the simplified TEHV geometry, comprising a non-physiological hinge design. This may have contributed to the continuous thrombus deposition and pannus formation at the hinge region, which may have finally hindered the development of a confluent endothelium during the first 8 weeks after implantation. Notably, at every time point considered in our present analysis, the hinge region of first-generation TEHVs presented with an abundant amount of inflammation-associated cells (i.e.: leukocytes, eosinophils, macrophages, multinucleated giant cells, and α-SMA+ cells) which are involved in the formation of the pannus and the associated fibrotic tissue33 (Fig. 8A).
As previously reported, first-generation TEHVs showed good early recellularization, self-repair capacity, and good valve performance within the first 8 weeks in-vivo. However, mild to moderate insufficiency was first observed at 16 weeks, and valvular performance gradually worsened over time, with moderate-to severe insufficiency at 24 weeks, which was mainly caused by wall/leaflet fusion phenomena6 (Fig. 8A).
Taken together, the results of the present study extend our understanding of the maladaptive remodeling observed in our first-generation TEHVs. As highlighted by Fig. 8A, our findings support the hypothesis that the extended presence of M1, combined with the increasing number of M2 macrophages over time and the lack of a confluent endothelium in first-generation TEHVs significantly impacted valve remodeling by inducing myofibroblast differentiation, causing pannus formation and subsequent increase in the hinge thickness during the first remodeling phases.
Second-generation TEHVs, towards a native-like remodeling
To date, independently of the tissue engineering technology used6,47–53, several studies—among which also our first-generation TEHV—reported a gradual loss of TEHV performance within few months after implantation, due to maladaptive tissue remodeling (thickening, leaflet shortening). However, here we show that the tissue analysis of our second-generation TEHVs did not reveal signs of pannus formation nor thickening of the hinge area. Importantly, second-generation TEHVs presented with much less leaflet shortening when compared to their first-generation counterparts. Notably, it appears that both TEHVs generations undergo an early shortening within the first 8 weeks, which then continues in the first-generation valves leading to functional failure (negative remodeling-driven continuous shortening), while the leaflet length remains completely stable and unchanged over time in the second-generation TEHVs, thereby maintaining an excellent performance profile (functional remodeling).
In fact, the improved and more physiological geometry of second-generation TEHVs is not only beneficial from a mechanical point of view, but also from an inflammatory host cell response perspective (Fig. 8B). Indeed, the long-term performance demonstrated by our second-generation TEHVs7 was characterized by an overall low inflammatory cell infiltration, negligible amount of macrophages, and, importantly, the absence of α-SMA+ cells in the hinge region at all the time-points considered (acute, 8 weeks, and 52 weeks). This, in relation to the complete endothelialization of the hinge area already at 8 weeks after implantation, resulted in an overall milder tissue inflammation (Fig. 8B).
Finally, this controlled inflammatory response is reflected by the observation of positive tissue remodeling outcomes. In this regard, we previously demonstrated that, similarly to a native valve, our computational modeling-inspired valve geometry can better sustain strain on the valve leaflets, thereby ensuring a more physiological long-term performance7. Indeed, one of the major causes of leaflet shortening has been identified in leaflet compression. While first-generation TEHVs showed an overall compression of the leaflet, from the coaptation to the hinge region, second-generation TEHV geometry could efficiently limit leaflet compression to just the coaptation area8. Second, we did neither detect thickening nor pannus formation in the hinge area. We may therefore hypothesize that second-generation TEHV geometry seem to better mimic native leaflet anatomy in the hinge area, thereby promoting the wash-out of fibrin deposits and preventing blood stagnation (Fig. 8B). The resulting favorable hemodynamics may therefore have enabled long-term performance of such second-generation TEHVs7.
8 weeks in-vivo follow-up, a turning point in the TEHV remodeling process?
As highlighted by our findings both generations of TEHVs presented with promising cellular infiltration and self-repair (remodeling) potential up to 8 weeks in-vivo. However, it is important to recognize that the remodeling process of first- and second-generation TEHV progresses into two distinct directions beyond 8 weeks (Fig. 8A,B). So far, the relevance of TEHV geometry was mainly considered on a mechanical8 and/or functional7 level. In the present study, we demonstrate that the TEHV geometry also strongly influences the outcome on a host cell response level (Fig. 8A,B).
At 8 weeks post implantation, first- and second-generation TEHVs showed comparable remodeling of the leaflet, with similar values of leaflet lengths (23% vs. 19% shortening for first- and second-generation, respectively) and hinge thicknesses. To the contrary, the differences observed in the number, phenotype, and distribution of infiltrating cells was substantially different underscoring the importance and impact of TEHV geometry. On one hand, first-generation TEHVs showed abundant cell infiltration, with approximately 20 times more cells per μm3 than second-generation TEHVs at the same time point. Next, abundance of inflammatory cells, such as eosinophilic cells, M1 macrophages, α-SMA+ cells, together with lack of a confluent endothelium in the hinge area were detected.
On the other hand, computational modeling-inspired second-generation TEHVs demonstrated an overall lower cellular infiltration with the negligible presence of M1/M2 and α-SMA+ cells already 8 weeks after implantation. Remarkably, endothelialization of the hinge region was complete already at this time point. Hence, despite a comparable leaflet morphology, our qualitative and quantitative cell analysis indicates a substantial difference between the valves already at 8 weeks that resulted in two distinct remodeling outcomes (maladaptive first-generation TEHVs versus adaptive and functional in second-generation TEHVs) beyond 8 weeks. This finding highlights the importance of early host cell response in controlling long-term valvular remodeling, and provides important insight on time and type of cells that could be included in in-silico models to further enhance the outcome on tissue remodeling prediction9.
Limitations
This study is an in-depth evaluation of TEHV explants obtained from previously performed in-vivo transcatheter implantations of two independent studies6,7. Consequently, the available time points and number of samples were limited and unpaired between the experiments (Table 1). Hence, the possibility to perform statistical analyses to compare first- and second-generation THEVs was limited. Despite this, we showed that both TEHVs generations underwent an initial leaflet shortening at 8 weeks follow-up. However, first-generation TEHVs experienced a progressive leaflet shortening, leading to a 70% reduction in length at 24 weeks post-implantation. To the contrary, leaflet shortening for second-generation TEHV did not progress over time thereby enabling the TEHV to remain functional for up to 1 year. This result is in line with what was previously reported for second-generation TEHVs7, even though a direct comparison between these studies is not possible because of 1) the different amount of samples used to evaluate the leaflet length (117 vs 3 valve explants) and 2) the different analysis techniques adopted to measure the leaflet length (caliper measurement7 vs. histology section measurement). In this regard, it has been showed that a collagenous tissue processed for histology (i.e.: using formaldehyde fixation and paraffin wax embedding) can be subjected to a 33% shrinkage54. Our study might therefore also highlight the importance of choosing the most appropriate measurement strategy to precisely report explanted TEHV remodeling measurements. In addition, immunohistochemistry proved to be a suboptimal technique to evaluate the presence of ECs due to cutting artefacts that may have caused cell detachment and lack of visible staining. In this regard, future studies should also better assess the integrity and functionality of the ECs layer, as well as evaluate the presence of activated platelets and microvesicles in the plasma. In this regard, analyses of anticoagulation and anti-thrombotic properties of ECs should be carefully considered when planning future in-vivo studies.
Next, we here focused our analysis on the hinge area of the TEHVs that, due to its important load-bearing activity, is subjected to high deformations24. Indeed, mechanical strain is a well-known regulator of cell behavior and differentiation25, and can therefore impact the (mal)adaptive remodeling phenomena in TEHVs. However, future in-vivo studies should consider additional time points as well as different TEHVs regions (e.g. the leaflets), to assess the first stages of inflammation (3–4 weeks follow up) and the resolution of the inflammatory status (12–24 months).
Finally, future studies should investigate how TEHV geometry will impact on the mechanical and hemodynamic valvular environment, also taking into consideration blood flow patterns through the valve, to better understand the mechanobiology of valvular remodeling. In this context, in-depth understanding of the molecular pathways underlying the complex interactions between inflammatory host cells, matrix remodeling, and scaffold degradation processes over time, may be crucial to better predict or even to anticipate (mal)adaptive remodeling phenomena.
Conclusions
This study highlights the strong interplay between TEHV geometry and its related inflammatory host cell response, which ultimately drives the tissue remodeling outcomes in TEHVs. First-generation TEHVs, with a simple valve-geometry, experienced a chronic inflammatory response characterized by abundant presence of M1 and M2 macrophages and α-SMA+ cells, which finally led to leaflet retraction and valve insufficiency. In contrast, second-generation TEHVs displayed an overall lower inflammatory response with only few M1 and M2 macrophages and α-SMA+ cells being present. These results highlight how an analytical, computational-inspired TEHV geometry does not only impact the mechanical strain distribution on the leaflets which is critical for valve performance, but also how it orchestrates host cell response towards functional remodeling, thereby enabling long-term performance of a TEHV. Our findings further provide important insight into the (inflammatory) host cell response and the related remodeling processes of TEM-based TEHVs which represents a key requisite for the safe and successful clinical translation of such technologies.
Methods
In this study, we performed a pooled, in-depth analysis of TEM-based TEHV tissue explants (n = 20) from our previously reported in-vivo studies6,7, as well as from additional unpublished data. The ethics committee and local authorities (Veterinäramt, Gesundheitsdirektion, Kanton Zürich [197/2010], Switzerland and the Regional Office for Health and Social Affairs Berlin, LAGeSo, Berlin; approval.
no. G0111/11) approved the previously reported in-vivo studies6,7, which were performed in compliance with the Guide for the Care and Use of Laboratory Animals, published by the National Institutes of Health (NIH publication No. 85–23), as well as the guidelines of the European and German societies of Laboratory Animal Science (FELASA, GV-SOLAS) and the ARRIVE guidelines (Animal Research; Reporting of in-vivo Experiments). Detailed information about the manufacturing, in-vitro characterization, and in-vivo testing of first-5 and second-generation7 TEHV have been previously reported6,7. Compared to first-generation TEHVs6, the use of an insert8 to impose a computational modelling-inspired valve geometry was the only difference in the manufacturing protocol of second-generation TEHVs7.
According to the follow-up schemes of our in-vivo studies6,7, a total of fifteen TEHV tissue samples (n = 15) were obtained from explants at the following time points: acute (considered as control), 8 weeks, 16 weeks, 24 weeks, and 52 weeks (1 year). The overview of available samples is reported in Table 1. In addition, the tissue samples for the acute (n = 2) and 8 weeks time point (n = 3) of the second-generation valve were obtained from an independent pilot series of animals (n = 5) which has not been published before (unpublished data), and were produced using the same culture conditions. Qualitative and quantitative analyses have been performed as described below to evaluate the inflammatory host cell response to the implanted TEHVs particularly in the hinge region of the leaflets, as it acknowledged to be the most subjected area to maladaptive remodeling phenomena.
Qualitative tissue analysis
Samples from explanted TEHVs (Table 1) were analyzed qualitatively to characterize the presence of inflammatory host cells using immunofluorescence, histology, immunohistochemistry, and scanning electron microscopy (SEM) techniques.
(Immuno)histochemistry and immunofluorescence stainings
In brief, TEHVs samples were fixed in formalin, embedded into paraffin, and cut consecutively into 5 µm slices with a sliding microtome at room temperature. The specimens were deparaffinized by treatment with xylene followed by a series of decreasing concentrations of ethanol (100–50%). Cellular infiltration and tissue appearance were evaluated by using Haematoxilin and Eosin (H&E) and Masson Goldner (MG) staining, and CD31, von Willebrand Factor (VWF), and α-SMA staining. The slides were visualized by Zeiss Mirax Midi microscope (Carl Zeiss Microimaging) and assessed with Pannoramic Viewer (3DHistech).
To characterize the phenotype of the infiltrated cells within the explanted TEHVs, immunofluorescence was performed following antigen retrieval using citrate (10 mM citric acid at pH 6.0) which was then brought to boiling temperature (96 °C) for 20 min. Primary antibody for CCR7 (M1 marker) and CD163 (M2 marker) were incubated for over-night at 4 °C. After washing with PBS, secondary antibodies were applied for 2 h (Supplementary Table 1). Cell nuclei were counterstained with DAPI. The stained sections were visualized using a fluorescence slide scanner (ZEISS Axio Scan.Z1, Carl Zeiss AG). Image processing was performed using the Axio Scan.Z1 ZEN lite imaging software (Blue version, 2012; Carl Zeiss AG).
Scanning electron microscopy (SEM)
SEM was used to assess and confirm the degree of endothelialization for the two TEHVs geometries6,7. For further details see the Supplementary Material section.
Quantitative tissue analysis
Inflammatory host cell infiltration
Cellular infiltration was quantified automatically and manually with ImageJ software55 in three pictures across the hinge area and in two consecutive sections for a total thickness of 10 µm (20 × magnification; area comprising 420,000 µm2 per picture). Pictures of stained sections were converted into grey-value images (16-bit). Quantification was performed by counting the cells positive for CCR7, CD163, or a combination of both (double stained cells) and compared to the total number of cells, detected via DAPI. The total number of cells infiltrating the wall region was used as control value for the complete cellular infiltration in the hinge area.
Morphological evaluation
Hinge thickness and leaflet length were measured manually for both first- and second-generation TEHVs using the Panoramic Viewer software (3DHistech, Ltd.). For both TEHVs geometries, hinge thickness was measured in two different sections of 5 μm each, and in three locations per section, for a total of 6 measurements. Leaflet length was measured in two different sections of 5 μm each, by using the highest number of segments possible to increase the accuracy of the measurements. Analyzed samples comprised the following follow-up time-points: acute, 8 weeks, 16 weeks, 24 weeks, and 52 weeks (Table 1).
Statistics
Measurements are represented as mean value ± standard deviation unless stated otherwise. Leaflet length and hinge thickness measurements were averaged for each sample (Supplementary Table 2).
Supplementary information
Acknowledgments
The authors gratefully acknowledge the funding from the European Union’s Seventh Framework Program (FP7/2007-2013) under grant agreement n° 242008. S.E.M. was supported by the University of Zurich Forschnugskredit (FK-14-031). E.S.F. was partly funded through the Swiss National Science Foundation (PZ00P3_180138). M.Y.E. and S.L. have received funding from the European Research Council (ERC) under the European Union’s Horizon 2020 research and innovation programme, grant agreement no. 852814 (TAVI4Life) and grant agreement no. 802967 (MechanoSignaling). We are thankful to Flurin Arner for supporting and contributing to this work.
Author contributions
S.P.H. and F.P.T.B. obtained the funding. S.E.M, E.S.F., and P.E.D. designed the study concept. S.E.M. and M.H. performed the experiments. S.E.M. analyzed the data. S.E.M., E.S.F., V.L. P.E.D., M.H., L.F., N.C., and S.L. performed post-mortem evaluation. S.E.M, E.S.F., V.L., P.E.D., M.H., L.F., N.C., S.L., F.P.T.B., V.F., S.P.H., and M.Y.E. drafted and/or revised the manuscript for critical content. S.E.M. wrote the manuscript. Administrative, technical, or supervisory tasks were handled by S.E.M., M.Y.E, and S.P.H.
Data availability
Data are available upon request and completion of a Materials Transfer Agreement (MTA).
Competing interests
V. Falk has disclosed relevant financial activities outside the submitted work with the following commercial entities: Medtronic GmbH, Boston Scientific and Edwards Lifesciences in relation to educational grants (including travel support) fees for lectures and speeches, fees for professional consultation and research and study funds. F.P.T. Baaijens and S.P. Hoerstrup are shareholders at Xeltis BV and LifeMatrix AG. M.Y. Emmert is a shareholder at LifeMatrix AG. S. Loerakker, F.P.T. Baaijens, and S.P. Hoerstrup are inventors on patent “Controlling TEHV geometry by using predefined inserts during culture” (WO2015044190 A1) held by Eindhoven University of Technology. This patent covers how the shape of the heart valves can be controlled and maintained during the in vitro culture phase. The authors declare no competing interests.
Footnotes
Publisher's note
Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
These authors contributed equally: Sarah E. Motta and Emanuela S. Fioretta.
Supplementary information
is available for this paper at 10.1038/s41598-020-76322-9.
References
- 1.Leopold JA. Cellular mechanisms of aortic valve calcification. Circ. Cardiovasc. Interv. 2012;5:605–614. doi: 10.1161/CIRCINTERVENTIONS.112.971028. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 2.Langer R, Vacanti JP. Tissue engineering. Science (80-) 1993;260:920–926. doi: 10.1126/science.8493529. [DOI] [PubMed] [Google Scholar]
- 3.Fioretta, E. S. et al. Next-generation tissue-engineered heart valves with repair, remodelling and regeneration capacity. Nat Rev Cardiol. 10.1038/s41569-020-0422-8 (2020). [DOI] [PubMed]
- 4.Fioretta ES, Dijkman PE, Emmert MY, Hoerstrup SP. The future of heart valve replacement: recent developments and translational challenges for heart valve tissue engineering. J Tissue Eng Regen Med. 2017 doi: 10.1002/term.2326. [DOI] [PubMed] [Google Scholar]
- 5.Wissing TB, Bonito V, Bouten CVC, Smits AIPM. Biomaterial-driven in situ cardiovascular tissue engineering—a multi-disciplinary perspective. NPJ Regen. Med. 2017;2:18. doi: 10.1038/s41536-017-0023-2. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 6.Driessen-Mol A, et al. Transcatheter implantation of homologous ‘off-the-shelf’ tissue-engineered heart valves with self-repair capacity: long-term functionality and rapid in vivo remodeling in sheep. J Am Coll Cardiol. 2014;63:1320–1329. doi: 10.1016/j.jacc.2013.09.082. [DOI] [PubMed] [Google Scholar]
- 7.Emmert, M. Y. et al. Computational modeling guides tissue-engineered heart valve design for long-term in vivo performance in a translational sheep model. Sci Transl Med10 , 1–13 (2018). [DOI] [PubMed]
- 8.Sanders B, et al. Improved geometry of decellularized tissue engineered heart valves to prevent leaflet retraction. Ann. Biomed. Eng. 2016;44:1061–1071. doi: 10.1007/s10439-015-1386-4. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 9.Loerakker S, Ristori T, Baaijens FP. A computational analysis of cell-mediated compaction and collagen remodeling in tissue-engineered heart valves. J. Mech. Behav. Biomed. Mater. 2016;58:173–187. doi: 10.1016/j.jmbbm.2015.10.001. [DOI] [PubMed] [Google Scholar]
- 10.Hans CP, et al. Transcriptomics analysis reveals new insights into the roles of Notch1 signaling on macrophage polarization. Sci. Rep. 2019;9:7999. doi: 10.1038/s41598-019-44266-4. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 11.Londono R, Badylak SF. Biologic scaffolds for regenerative medicine: mechanisms of in vivo remodeling. Ann. Biomed. Eng. 2015;43:577–592. doi: 10.1007/s10439-014-1103-8. [DOI] [PubMed] [Google Scholar]
- 12.Syedain Z, et al. Tissue engineering of acellular vascular grafts capable of somatic growth in young lambs. Nat. Commun. 2016;7:1–9. doi: 10.1038/ncomms12951. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 13.Roh JD, et al. Tissue-engineered vascular grafts transform into mature blood vessels via an inflammation-mediated process of vascular remodeling. Proc. Natl. Acad. Sci. U. S. A. 2010;107:4669–4674. doi: 10.1073/pnas.0911465107. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 14.Matsumura G, Miyagawa-Tomita S, Shin’oka T, Ikada Y, Kurosawa H. First evidence that bone marrow cells contribute to the construction of tissue-engineered vascular autografts in vivo. Circulation. 2003;108:1729–1734. doi: 10.1161/01.CIR.0000092165.32213.61. [DOI] [PubMed] [Google Scholar]
- 15.Hibino N, et al. The innate immune system contributes to tissue-engineered vascular graft performance. Faseb J. 2015;29:2431–2438. doi: 10.1096/fj.14-268334. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 16.Fukunishi T, et al. Tissue-engineered small diameter arterial vascular grafts from cell-free nanofiber PCL/Chitosan scaffolds in a sheep model. PLoS ONE. 2016;11:e0158555. doi: 10.1371/journal.pone.0158555. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 17.Lawson JH, et al. Bioengineered human acellular vessels for dialysis access in patients with end-stage renal disease: two phase 2 single-arm trials. Lancet (Lond. Engl.) 2016;387:2026–2034. doi: 10.1016/S0140-6736(16)00557-2. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 18.Kirkton, R. D. et al. Bioengineered human acellular vessels recellularize and evolve into living blood vessels after human implantation. Sci. Transl. Med.11, 1–11 (2019). [DOI] [PMC free article] [PubMed]
- 19.Franz S, Rammelt S, Scharnweber D, Simon JC. Immune responses to implants—a review of the implications for the design of immunomodulatory biomaterials. Biomaterials. 2011;32:6692–6709. doi: 10.1016/j.biomaterials.2011.05.078. [DOI] [PubMed] [Google Scholar]
- 20.Mosser DM, Edwards JP. Exploring the full spectrum of macrophage activation. Nat. Rev. Immunol. 2008;8:958–969. doi: 10.1038/nri2448. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 21.Boehler RM, Graham JG, Shea LD. Tissue engineering tools for modulation of the immune response. Biotechniques. 2011;51:239–240, 242, 244 passim. doi: 10.2144/000113754. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 22.Tidball JG, Villalta SA. Regulatory interactions between muscle and the immune system during muscle regeneration. Am. J. Physiol. Regul. Integr. Comp. Physiol. 2010;298:R1173–R1187. doi: 10.1152/ajpregu.00735.2009. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 23.Naito Y, et al. Vascular tissue engineering: towards the next generation vascular grafts. Adv. Drug. Deliv. Rev. 2011;63:312–323. doi: 10.1016/j.addr.2011.03.001. [DOI] [PubMed] [Google Scholar]
- 24.Katayama S, Umetani N, Sugiura S, Hisada T. The sinus of Valsalva relieves abnormal stress on aortic valve leaflets by facilitating smooth closure. J. Thorac. Cardiovasc. Surg. 2008;136:1528–1535, 1535.e1. doi: 10.1016/j.jtcvs.2008.05.054. [DOI] [PubMed] [Google Scholar]
- 25.Balachandran K, Sucosky P, Yoganathan AP. Hemodynamics and mechanobiology of aortic valve inflammation and calcification. Int. J. Inflam. 2011;2011:263870. doi: 10.4061/2011/263870. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 26.Mariani E, Lisignoli G, Borzì RM, Pulsatelli L. Biomaterials: foreign bodies or tuners for the immune response? Int. J. Mol. Sci. 2019;20:636. doi: 10.3390/ijms20030636. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 27.Morris AH, Stamer DK, Kyriakides TR. The host response to naturally-derived extracellular matrix biomaterials. Semin. Immuno.l. 2017;29:72–91. doi: 10.1016/j.smim.2017.01.002. [DOI] [PubMed] [Google Scholar]
- 28.Chester AH, et al. The living aortic valve: from molecules to function. Glob. Cardiol. Sci. Pr. 2014;2014:52–77. doi: 10.5339/gcsp.2014.52. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 29.Ayoub S, et al. Heart valve biomechanics and underlying mechanobiology. Compr. Physiol. 2016;6:1743–1780. doi: 10.1002/cphy.c150048. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 30.Klopfleisch R, Jung F. The pathology of the foreign body reaction against biomaterials. J. Biomed. Mater. Res. A. 2017;105:927–940. doi: 10.1002/jbm.a.35958. [DOI] [PubMed] [Google Scholar]
- 31.Loerakker S, Argento G, Oomens CW, Baaijens FP. Effects of valve geometry and tissue anisotropy on the radial stretch and coaptation area of tissue-engineered heart valves. J. Biomech. 2013;46:1792–1800. doi: 10.1016/j.jbiomech.2013.05.015. [DOI] [PubMed] [Google Scholar]
- 32.Ristori T, Obbink-Huizer C, Oomens CW, Baaijens FP, Loerakker S. Efficient computational simulation of actin stress fiber remodeling. Comput. Methods Biomech. Biomed. Eng. 2016;19:1347–1358. doi: 10.1080/10255842.2016.1140748. [DOI] [PubMed] [Google Scholar]
- 33.Kumar V, Sharma A. Neutrophils: Cinderella of innate immune system. Int. Immunopharmacol. 2010;10:1325–1334. doi: 10.1016/j.intimp.2010.08.012. [DOI] [PubMed] [Google Scholar]
- 34.Wang Y-Y, et al. Macrophage-to-myofibroblast transition contributes to interstitial fibrosis in chronic renal allograft injury. J. Am. Soc. Nephrol. 2017;28:2053–2067. doi: 10.1681/ASN.2016050573. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 35.Braga TT, Agudelo JSH, Camara NOS. Macrophages during the fibrotic process: M2 as friend and foe. Front. Immunol. 2015;6:602. doi: 10.3389/fimmu.2015.00602. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 36.Shapouri-Moghaddam A, et al. Macrophage plasticity, polarization, and function in health and disease. J. Cell. Physiol. 2018;233:6425–6440. doi: 10.1002/jcp.26429. [DOI] [PubMed] [Google Scholar]
- 37.Daley JM, Brancato SK, Thomay AA, Reichner JS, Albina JE. The phenotype of murine wound macrophages. J. Leukoc. Biol. 2010;87:59–67. doi: 10.1189/jlb.0409236. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 38.Hesketh, M., Sahin, K. B., West, Z. E. & Murray, R. Z. Macrophage phenotypes regulate scar formation and chronic wound healing. Int. J. Mol. Sci.18 (2017). [DOI] [PMC free article] [PubMed]
- 39.Zhu Z, Ding J, Ma Z, Iwashina T, Tredget EE. Alternatively activated macrophages derived from THP-1 cells promote the fibrogenic activities of human dermal fibroblasts. Wound Repair Regen. 2017;25:377–388. doi: 10.1111/wrr.12532. [DOI] [PubMed] [Google Scholar]
- 40.Glim JE, Niessen FB, Everts V, van Egmond M, Beelen RHJ. Platelet derived growth factor-CC secreted by M2 macrophages induces alpha-smooth muscle actin expression by dermal and gingival fibroblasts. Immunobiology. 2013;218:924–929. doi: 10.1016/j.imbio.2012.10.004. [DOI] [PubMed] [Google Scholar]
- 41.Cai Q, Lanting L, Natarajan R. Interaction of monocytes with vascular smooth muscle cells regulates monocyte survival and differentiation through distinct pathways. Arter. Thromb Vasc Biol. 2004;24:2263–2270. doi: 10.1161/01.ATV.0000146552.16943.5e. [DOI] [PubMed] [Google Scholar]
- 42.Gould ST, Matherly EE, Smith JN, Heistad DD, Anseth KS. The role of valvular endothelial cell paracrine signaling and matrix elasticity on valvular interstitial cell activation. Biomaterials. 2014;35:3596–3606. doi: 10.1016/j.biomaterials.2014.01.005. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 43.Butcher JT, Nerem RM. Valvular endothelial cells regulate the phenotype of interstitial cells in co-culture: effects of steady shear stress. Tissue Eng. 2006;12:905–915. doi: 10.1089/ten.2006.12.905. [DOI] [PubMed] [Google Scholar]
- 44.Jana S, Tranquillo RT, Lerman A. Cells for tissue engineering of cardiac valves. J. Tissue Eng. Regen. Med. 2016;10:804–824. doi: 10.1002/term.2010. [DOI] [PubMed] [Google Scholar]
- 45.Cushing MC, Liao JT, Anseth KS. Activation of valvular interstitial cells is mediated by transforming growth factor-beta1 interactions with matrix molecules. Matrix Biol. 2005;24:428–437. doi: 10.1016/j.matbio.2005.06.007. [DOI] [PubMed] [Google Scholar]
- 46.Benton JA, DeForest CA, Vivekanandan V, Anseth KS. Photocrosslinking of gelatin macromers to synthesize porous hydrogels that promote valvular interstitial cell function. Tissue Eng. Part A. 2009;15:3221–3230. doi: 10.1089/ten.tea.2008.0545. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 47.Reimer J, et al. Implantation of a tissue-engineered tubular heart valve in growing lambs. Ann. Biomed. Eng. 2016 doi: 10.1007/s10439-016-1605-7. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 48.Syedain Z, et al. 6-Month aortic valve implantation of an off-the-shelf tissue-engineered valve in sheep. Biomaterials. 2015;73:175–184. doi: 10.1016/j.biomaterials.2015.09.016. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 49.Schmidt D, et al. Minimally-invasive implantation of living tissue engineered heart valves: a comprehensive approach from autologous vascular cells to stem cells. J. Am. Coll. Cardiol. 2010;56:510–520. doi: 10.1016/j.jacc.2010.04.024. [DOI] [PubMed] [Google Scholar]
- 50.Weber B, et al. Off-the-shelf human decellularized tissue-engineered heart valves in a non-human primate model. Biomaterials. 2013;34:7269–7280. doi: 10.1016/j.biomaterials.2013.04.059. [DOI] [PubMed] [Google Scholar]
- 51.Flanagan TC, et al. In vivo remodeling and structural characterization of fibrin-based tissue-engineered heart valves in the adult sheep model. Tissue Eng. Part A. 2009;15:2965–2976. doi: 10.1089/ten.tea.2009.0018. [DOI] [PubMed] [Google Scholar]
- 52.Gottlieb D, et al. In vivo monitoring of function of autologous engineered pulmonary valve. J. Thorac. Cardiovasc. Surg. 2010;139:723–731. doi: 10.1016/j.jtcvs.2009.11.006. [DOI] [PubMed] [Google Scholar]
- 53.Schmitt B, et al. Percutaneous pulmonary valve replacement using completely tissue-engineered off-the-shelf heart valves: six-month in vivo functionality and matrix remodelling in sheep. EuroIntervention. 2016;12:62–70. doi: 10.4244/EIJV12I1A12. [DOI] [PubMed] [Google Scholar]
- 54.Chatterjee S. Artefacts in histopathology. J. Oral Maxillofac. Pathol. 2014;18:S111–S116. doi: 10.4103/0973-029X.141346. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 55.Jensen EC. Quantitative analysis of histological staining and fluorescence using ImageJ. Anat. Rec. 2013;296:378–381. doi: 10.1002/ar.22641. [DOI] [PubMed] [Google Scholar]
Associated Data
This section collects any data citations, data availability statements, or supplementary materials included in this article.
Supplementary Materials
Data Availability Statement