Abstract
Cerebrovascular reactivity (CVR), defined as the cerebral blood flow response to a vasoactive stimulus, is an imaging biomarker with demonstrated utility in a range of diseases and in typical development and aging processes. A robust and widely implemented method to map CVR involves using a breath-hold task during a BOLD fMRI scan Recording end-tidal CO2 (PETCO2) changes during the breath-hold task is recommended to be used as a reference signal for modeling CVR amplitude in standard units (%BOLD/mmHg) and CVR delay in seconds. However obtaining reliable PETCO2 recordings requires equipment and task compliance that may not be achievable in all settings. To address this challenge, we investigated two alternative reference signals to map CVR amplitude and delay in a lagged general linear model (lagged-GLM) framework: respiration volume per time (RVT) and average gray matter BOLD response (GM-BOLD). In 8 healthy adults with multiple scan sessions, we compare spatial agreement of CVR maps from RVT and GM-BOLD to those generated with PETCO2. We define a threshold to determine whether a PETCO2 recording has “sufficient” quality for CVR mapping and perform these comparisons in 16 datasets with sufficient PETCO2 and 6 datasets with insufficient PETCO2. When PETCO2 quality is sufficient, both RVT and GM-BOLD produce CVR amplitude maps that are nearly identical to those from PETCO2 (after accounting for differences in scale), with the caveat they are not in standard units to facilitate between-group comparisons. CVR delays are comparable to PETCO2 with an RVT regressor but may be underestimated with the average GM-BOLD regressor. Importantly, when PETCO2 quality is insufficient, RVT and GM-BOLD CVR recover reasonable CVR amplitude and delay maps, provided the participant attempted the breath-hold task. Therefore, our framework offers a solution for achieving high quality CVR maps in both retrospective and prospective studies where sufficient PETCO2 recordings are not available and especially in populations where obtaining reliable measurements is a known challenge (e.g., children). Our results have the potential to improve the accessibility of CVR mapping and to increase the prevalence of this promising metric of vascular health.
Keywords: Cerebrovascular reactivity, Breath-hold, BOLD fMRI, Respiration volume per time
1. Introduction
The regulation of cerebral blood flow (CBF) is critical to maintain proper brain function. One mechanism that allows for tight regulation of CBF is the dilation and constriction of arterioles to increase or decrease blood flow, respectively. This mechanism can be characterized by a metric called cerebrovascular reactivity (CVR), defined as the CBF response to a vasoactive stimulus. It represents the ability of the brain’s blood vessels to dilate or constrict and is thus an indicator of vascular health. CVR has gained attention in recent years as an imaging biomarker in a range of pathologies, including stroke (Krainik et al., 2005), atherosclerotic disease (Donahue et al., 2014), multiple sclerosis (Marshall et al., 2014), moyamoya disease (Mikulis et al., 2005), sickle cell anemia (Václavů et al., 2019), and brain tumors (Fierstra et al., 2018), among others. In addition, changes in CVR throughout developmental (Leung et al., 2016b) and aging (McKetton et al., 2018) processes have been reported.
CVR measurements require two components: 1) a vasoactive stimulus to elicit a change in blood flow, and 2) a measure of the CBF response. There are a range of different vasoactive stimuli and neuroimaging methods to record the CBF response, each with unique advantages and limitations. Several excellent review articles explore the rationale and methodological considerations for CVR mapping (Fierstra et al., 2013; Liu et al., 2019; Sleight et al., 2021; Williams et al., 2021), and we direct the reader to these sources for more details. We will focus on an established approach for CVR measurements, which involves a breath-hold task during a blood oxygenation level dependent (BOLD) MRI scan (Urback et al., 2017). The breath-hold task modulates endogenous levels of carbon dioxide (CO2), which serves as a vasodilator, causing a systemic increase in blood flow. The resulting blood flow response throughout the brain is detected by the BOLD MRI contrast, a surrogate measure of CBF (Pinto et al., 2021).
Although breath-holds are widely used in CVR mapping (Urback et al., 2017), including in populations with known task-compliance challenges (Dlamini et al., 2018; Handwerker et al., 2007; Thomason et al., 2005), there are nuances to obtaining accurate CVR measurements with this experimental design. Guidance for exemplar CVR measurements involves characterizing CO2 changes throughout the task. Commonly, end-tidal CO2, the partial pressure of CO2 at the end of an exhale, is measured as a surrogate for arterial CO2 (McSwain et al., 2010; Peebles et al., 2007). This allows CVR to be reported in normalized, standard units as the blood flow response per unit change of CO2 (%BOLD/mmHg). However, end-tidal CO2 measurements require external physiological monitoring equipment (e.g., gas analyzer), which may not be available in all clinical or research imaging centers. Additionally, there are challenges in achieving reliable CO2 recordings. Therefore, obtaining end-tidal CO2 measurements, which is critical for standard CVR measurements, may not be achieved in all subjects or settings.
The primary complication with end-tidal CO2 data quality in breath-hold tasks is obtaining measurements both before and after the breath-hold, which is critical for modeling CVR (Bright and Murphy, 2013; Murphy et al., 2011). This can be achieved by designing the breath-hold task with expirations both before and after the breath-hold period (Pinto et al., 2021). Unreliable estimates of these expiration end-tidal CO2 values may occur if the participant simply does not execute them as instructed, for example, by performing a brief inspiration instead. In addition, end-tidal CO2 measurements are typically acquired via a nasal cannula, which requires a participant to breathe through their nose for the duration of the experiment. Lapses in nose-breathing or variations in the pressure of exhaled air may also lead to inaccurate end-tidal values. Even in healthy adults, there are challenges in achieving successful end-tidal CO2 recordings. In a recent study of 10 healthy adults (Moia et al., 2021), 3 subjects were excluded due to poor CO2 data quality. There are added difficulties with cooperation in patient cohorts, particularly in those with cognitive impairments who may struggle to execute commands (Pujol et al., 1998; Schouwenaars et al., 2021). Obtaining high-quality data in younger participants also tends to be more challenging, with inconsistent performance of breathing tasks reported among children and adolescents (Stickland et al., 2021).
In this work, we aimed to find alternative strategies for mapping CVR that could be used in cases where end-tidal CO2 measurements are unavailable or unreliable. Specifically, we wanted to develop a method that considers not only the amplitude, but also the timing of the blood flow response (Bright et al., 2009; Chang et al., 2008; Duffin et al., 2015; Moia et al., 2020a). Variations in the response time may occur due to regional variations in the timing of arterial blood arrival and local regulation of vessel diameter (Donahue et al., 2016). Accounting for this “CVR delay” is not only important to achieve accurate CVR amplitudes but also serves as a separate metric of vascular health that is sensitive to cerebrovascular pathology (Donahue et al., 2016; Leung et al., 2016a; Sam et al., 2016; Stickland et al., 2021; Thomas et al., 2014; Thrippleton et al., 2018). We approached this problem in breath-hold task data using a lagged-general linear model (lagged-GLM approach) (Moia et al., 2021, 2020a; Stickland et al., 2021). We then compared results using end-tidal CO2, or two alternative regressors (reference signals), in the lagged-GLM (Table 1). These alternatives were selected based on the hypothesis they would be less susceptible to events that critically disrupt data quality compared to end-tidal CO2.
Table 1.
PETCO2 | RVT | GM-BOLD | |
---|---|---|---|
CVR delay measurement | Quantitative (seconds) |
Quantitative (seconds) |
Quantitative (seconds) |
CVR amplitude measurement | Standard (%BOLD/mmHg) |
Not standard, arbitrary (%BOLD/a.u.) | Not standard, unitless (%BOLD/%BOLD) |
Additional equipment required for acquisition | Nasal cannula and gas monitoring system | Respiratory belt (typically comes with scanner) | N/A |
Head motion confounds in reference signal | N/A | N/A | Present |
Sensitivity of data acquisition to participant compliance | Participant must breathe through their nose and start and end breath-hold on exhalation | Potential bias if participant’s breathing pattern changes (e.g., stomach vs. chest or shallow vs. deep breathing), belt must be positioned correctly | N/A |
PETCO2 = partial pressure of end-tidal CO2, RVT = respiration volume per time, GM-BOLD = average blood oxygenation level dependent signal in gray matter.
First, we investigated another measure of respiratory physiology, respiration volume per time (RVT) (Birn et al., 2008, 2006). RVT represents changes in both the rate and depth of breathing and is obtained by continuously measuring chest position via a pressure-sensitive belt worn around the chest or abdomen. RVT is an attractive alternative to end-tidal CO2 because it also captures whether the participant attempts the breath-hold task. Even if the end-tidal CO2 measurements do not reflect a change during the apnea period, there will be a decrease in RVT due to the pause in breathing. RVT and end-tidal CO2 are highly correlated, have similar overlap in the variance they explain in the BOLD signal, and consistent latencies at which they affect the BOLD signal (Chang and Glover, 2009). Additionally, a respiration belt is commonly found in most scanner set-ups, making it potentially more accessible than end-tidal CO2 measurements.
Second, we investigated a data-driven regressor using the average gray matter BOLD timeseries (GM-BOLD). The main advantage of the GM-BOLD signal is that no external monitoring equipment is required. Changes in the BOLD timeseries should be evident provided the participant attempted the breath-hold and achieved periods of hypercapnia (Bright and Murphy, 2013; Stickland et al., 2021). While the global BOLD signal or “refined” GM-BOLD regressors have been used in other CVR methods, including techniques that capture both amplitude and delay (Geranmayeh et al., 2015; Liu et al., 2017; Tong et al., 2011; Tong and Frederick, 2014; van Niftrik et al., 2016), our proposed approach simultaneously models other regressors (e.g., motion confounds) when searching for the optimum delay of the reference signal and outputs amplitude maps normalized to the input regressor amplitude (Moia et al., 2020a).
The aim of this work was to test if RVT or GM-BOLD timeseries can be used in a lagged-GLM framework to achieve estimates of CVR amplitude and delay that are spatially similar to those generated with the gold standard of end-tidal CO2, with the caveat that these alternative CVR amplitude measurements will no longer be in the standard, normalized units (%BOLD/mmHg) that are recommended for CVR comparisons across people and sessions (Kastrup et al., 2001; Murphy et al., 2011; Pinto et al., 2021; Sleight et al., 2021). We assess the agreement between CVR amplitude and delay maps in breath-hold fMRI datasets with high-quality or “sufficient” end-tidal CO2 data, and in those where end-tidal CO2 measurements were sub-optimal or “insufficient”. We hypothesized that in a lagged-GLM framework, using RVT and GM-BOLD as reference signals would produce CVR amplitude and delay measurements that are highly correlated with those produced by high-quality end-tidal CO2 measurements. In cases with unreliable end-tidal CO2 measurements, we hypothesized that RVT or GM-BOLD timeseries could be used to recover reasonable CVR amplitude and delay maps, provided that the participant attempted the breath-hold task.
2. Methods
2.1. Participants
A subset of the imaging and physiological data used in this manuscript have been published previously (Moia et al., 2021, 2020b). The full dataset includes ten healthy subjects (5F, 24–40y at the start of the experiment) with no history of psychiatric or neurological disorders. All subjects completed ten MRI sessions, which were scheduled exactly one week apart at the same time of day. MRI scanning took place using a 3T Siemens PrismaFit scanner with a 64-channel head coil. The study was approved by the Basque Center on Cognition, Brain and Language ethics committee. Informed consent was obtained before each MRI session.
Eight of the ten subjects were included in this analysis (sub-002, sub-003, sub-004, sub-006, sub-007, sub-008, sub-009, sub-010), based on those with sufficient data quality in the same two consecutive sessions (ses-02 and ses-03). Two additional sessions were included from three of the subjects (sub-006, sub-009, sub-010) to capture two consecutive sessions (ses-07 and ses-08 for sub-006 and sub-010; ses-08 and ses-09 for sub-009) with insufficient end-tidal CO2 timeseries (i.e., low power in the dominant frequency range of the breath-hold task, described in greater detail in Section 2.4.1). These eight subjects have similar demo-graphics to the complete ten (4F, 27–40y).
2.2. Data collection
2.2.1. Magnetic resonance imaging
Subjects underwent a variety of task-based and resting-state acquisitions during each MRI session, but the current study focuses on the multi-echo fMRI acquisition during a breath-hold (BH) task. The multi-echo fMRI protocol was a T2* -weighted, simultaneous multislice (multiband, or MB), gradient-echo echo planar imaging sequence provided by the Center for Magnetic Resonance Research (CMRR, Minnesota) with the following parameters: 340 vol, TR = 1.5 s, TEs = 10.6/28.69/46.78/64.87/82.96 ms, flip angle = 70°, MB acceleration factor = 4, GRAPPA = 2, 52 slices with inter-leaved acquisition, partial Fourier = 6/8, FoV = 211 × 211 mm2, voxel size = 2.4 × 2.4 × 3 mm3, phase encoding = AP, band-width = 2470 Hz/px, LeakBlock kernel reconstruction (Cauley et al., 2014) and SENSE coil combination (Sotiropoulos et al., 2013). Prior to the fMRI acquisition, single-band reference (SBRef) images were collected for each echo time to facilitate functional realignment and masking, and a pair of spin-echo echo planar images with opposite phase-encoding (AP or PA) directions and identical volume layout (TR = 2920 ms, TE = 28.6 ms, flip angle = 70°) were acquired to estimate field distortions. For anatomical co-registration and tissue segmentation, a T1-weighted MP2RAGE (TR = 5 s, TE = 2.98 ms, TI1 = 700 ms, TI2 = 2.5 s, flip angle 1 = 4°, flip angle 2 = 5°, GRAPPA = 3, 176 slices, FoV read = 256 mm, voxel size = 1 × 1 × 1 mm3, TA = 662 s) and a T2-weighted Turbo Spin Echo image (TR = 3.39 s, TE = 389 ms, GRAPPA = 2, 176 slices, FoV read = 256 mm, voxel size = 1 × 1 × 1 mm3, TA = 300 s) were acquired. All DICOM files were transformed into NIFTI files with dcm2nii and formated into Brain Imaging Data Structure (Gorgolewski et al., 2016) with heudiconv (Halchenko et al., 2019).
2.2.2. Physiological data
During scanning, expired CO2 and O2 pressures were recorded via a nasal cannula (Intersurgical) and gas analyzer (ADInstruments ML206). Chest position was measured with a respiratory effort transducer (BIOPAC) placed around the upper abdomen, on the area of highest expansion during breathing. These measurements were then transferred to a physiological monitoring system (BIOPAC MP150) that simultaneously recorded scan triggers. Physiological signals were sampled at 10 kHz, starting before and continuing after the fMRI scan to allow for shifting of regressors. Before processing, the files were converted to BIDS with phys2bids (The phys2bids developers, 2019) and the physiological signals were decimated to 40 Hz to reduce file sizes.
2.2.3. Breath-hold task
The BH task paradigm included eight repetitions of a 58 s BH trial. Within each trial, there were four paced breathing cycles (1 cycle = 3 s inhale and 3 s exhale), a 20 s BH, 3 s exhalation, and 11 s of free recovery breathing (Bright and Murphy, 2013). Participants were cued with visual instructions projected through a mirror on the head coil. A 15 s resting period was appended to the start and end of the paradigm to enable shifting of physiological regressors in subsequent analysis.
Prior to the scan, subjects were instructed about the importance of exhaling through their nose both before and after the BH period. These exhalations are critical because they provide end-tidal CO2 measurements to estimate arterial changes in CO 2 achieved by each BH (Bright and Murphy, 2013). If the exhale is not performed properly or the measurement is unreliable, it is not possible to obtain a standard CVR estimate in units of %BOLD/mmHg.
2.3. Data analysis
The MRI images and physiological data used in this study are available on OpenNeuro at doi:10.18112/openneuro.ds003192.v1.0.1 (Moia, Uruñuela, Ferrer, & Caballero-Gaudes, 2020). All code for pre-processing of the MRI data has been prepared to be run in a Singularity container, which is publicly available at https://git.bcbl.eu/smoia/euskalibur_container. The pre-processing pipeline is available at https://github.com/smoia/EuskalIBUR_preproc. Publicly available Python scripts, peakdet (Markello & DuPre, 2020) and phys2cvr (Moia, Vigotsky, & Zvolanek, 2022), were used for processing of CO2 recordings and computation of CVR parameter maps. The open-source Rapidtide v2.2.7 toolbox (B. deB Frederick, Salo, & Drucker, 2022) was used for exploratory analysis (see Discussion Section 4.3). Additional analysis code and details about how they were implemented for this manuscript are shared in the public GitHub repository: https://github.com/BrightLab-ANVIL/Zvolanek_2022.
2.3.1. MRI pre-processing
Key MRI pre-processing steps are discussed here, and more detailed information can be found in Moia et al. (2021). MRI preprocessing was performed with a series of custom scripts combining FSL (Jenkinson et al., 2012), AFNI (Cox, 1996), and ANTs (Tustison et al., 2014) commands. The T2-weighted image was skull-stripped and co-registered to the MP2RAGE. The MP2RAGE was segmented into gray matter (GM), white matter (WM), and cerebrospinal fluid (CSF) tissues. Then, the MP2RAGE was normalized to a resampled version (2.5 mm resolution) of the MNI152 6th generation template (FSL version, 1 mm resolution) (Grabner et al., 2006). The T2-weighted image was co-registered to the skull-stripped SBRef image of the first echo. Volume realignment of the functional data was performed using the SBRef of the first echo as the reference and applying the spatial transformation to all subsequent echoes (Jenkinson et al., 2002; Jenkinson and Smith, 2001). An optimal combination of the different echoes was created with tedana (DuPre et al., 2021, 2019), which weights each echo timeseries according to the voxelwise T2* value (Posse et al., 1999). Finally, the pair of spin-echo images with reverse phase-encoding directions was used to perform field distortion correction with Topup (Andersson et al., 2003). The optimally-combined, distortion-corrected data were used as the input for CVR modeling.
2.3.2. Reference signals
Three different reference signals were generated for each dataset, as depicted in Fig. 1: end-tidal CO2 (PETCO2), respiration volume per time (RVT), and the average gray matter BOLD signal (GM-BOLD).
End-tidal peaks were identified with a peak detection algorithm and manually reviewed. Linear interpolation was performed between the end-tidal peaks to create PETCO2 timeseries. Finally, PETCO2 timeseries were convolved with the two-gamma variate canonical hemodynamic response function (Friston et al., 1998).
Respiration recordings were processed using a custom MATLAB script. Maxima and minima in the belt trace were identified with a peak detection algorithm and manually inspected. The computation of respiration volume per time (RVT) requires alternating maxima and minima (Birn et al., 2006), but in an end-exhalation BH task, there are two consecutive minima due to exhales before and after the hold. To address this, only minima preceding the BH period were included. Linear envelopes of these maxima and minima were used to compute RVT as previously defined (Birn et al., 2006). Briefly, the difference in maxima and minima is computed at each timepoint and divided by the time between successive maxima. The RVT timeseries were then convolved with the respiration response function (RRF) (Birn et al., 2008). Importantly, all convolved RVT timeseries were z-normalized (i.e., zero mean and unit standard deviation). The normalization procedure was implemented to account for the high variability in RVT amplitudes (see Supplementary Figure S1 and Table S2). All subsequent “RVT” results refer to the convolved, normalized reference signal.
The average BOLD timeseries in GM was generated from the optimally-combined, distortion-corrected functional data with phys2cvr (Moia et al., 2022b). An eroded version of the co-registered GM mask (obtained by zeroing non-zero edge voxels within a 2.5 mm sigma Gaussian kernel with fslmaths) was used as the ROI for the average time-course extraction. The reference signal was then expressed in signal percentage change.
2.3.3. CVR amplitude and delay estimation
Voxelwise hemodynamic CVR amplitude and delay were computed using phys2cvr (Moia et al., 2022b) to implement a lagged-GLM framework that has been described previously (Moia et al., 2021, 2020a; Stickland et al., 2021). Each reference signal was considered independently from the others, but the same procedures outlined below were used for each CVR model.
First, all traces were shifted to maximize the cross-correlation with the up-sampled GM-BOLD timeseries (40 Hz to match the physiological signals). This “bulk” shift primarily accounts for measurement delay in the physiological recordings. Then, 61 shifted variants of each regressor (including the bulk shifted regressor) were created for each reference signal, in 0.3 s increments (Moia et al., 2020a). These shifts ranged ±9 s from the bulk shift. Separate GLMs were created for each shifted variant. In each case, fMRI data were modelled by a design matrix consisting of the shifted reference signal and the following nuisance regressors: Legendre polynomials up to the fourth-order, 6 realignment parameters, and their 6 temporal derivatives. Each lagged-GLM was fitted via orthogonal least squares (Moia et al., 2020a). The lagged-GLM with the maximum full model R2 was identified for each voxel; its corresponding shift (in seconds) determined the CVR delay, and its associated beta coefficient was extracted and rescaled to be expressed in percentage BOLD signal change (%BOLD). Therefore, the lagged-GLM generated two maps for each reference signal, as depicted in Fig. 1: CVR amplitude (in units of %BOLD normalized to the amplitude of the input regressor) and CVR delay (in seconds). Delay maps were centered on the median delay across GM voxels. Both CVR amplitude and delay maps were thresholded to remove voxels at or adjacent to boundary conditions (delay = −9, −8.7, + 8.7, +9 s) because they were considered not optimized by the lagged-GLM (Moia et al., 2020a). CVR amplitude and delay maps were normalized via nearest neighbor interpolation to the MNI152 6th generation template (FSL version, 1 mm resolution) resampled to 2.5 mm resolution.
2.4. Data summaries and comparisons
2.4.1. Determining sufficient reference signal quality
The quality of reference signals for each dataset was assessed by computing the relative power in the dominant frequency range of the BH task (0.014 to 0.020 Hz). This range is centered around 0.017 Hz, which corresponds to the 58 s BH cycle. MATLAB’s bandpower function was used to compute the total power between 0.014 to 0.020 Hz, as well as the total power in the signal, between 0 Hz and the Nyquist frequency (i.e., 20 Hz). Relative power was then calculated using the following equation:
Reference signals with greater than 50% power in the BH range were deemed “sufficient”, as more than half of the signal power is in the frequency range of interest. In the time domain, this relative power threshold corresponds to reference signals with clear signal changes during each BH cycle (Fig. 2). Reference signals with less than 50% power were categorized as “insufficient”.
2.4.2. Reference signal cross-correlations
Relationships between the reference signals for each dataset were assessed by computing the cross-correlation between each pair. The “bulk shifted” PETCO2 and RVT signals were used for these comparisons, which had already been shifted to maximize the cross-correlation with the GM-BOLD signal during CVR modeling (see Section 2.3.3). The additional cross-correlation was performed to understand the relationships between signals going into the lagged-GLM and to check for any remaining offsets that may explain differences in resulting CVR maps. The GM-BOLD signal was up-sampled to 40 Hz to match the temporal resolution of the physiological signals. Using MATLAB’s xcorr function, cross-correlations between each pair of reference signals were computed at 0.025 s increments (i.e., 40 Hz) within a range of ±9 s. Pearson correlations (r) were transformed to Fisher’s Z values to facilitate group averaging and comparisons.
2.4.3. CVR amplitude and delay values
The 98th percentile of brain voxels in each CVR amplitude map (after thresholding of voxels at the boundary) was computed using the fslstats function in FSL. For each reference signal, the kernel density estimation of the distribution of CVR amplitude and CVR delay values was computed with MATLAB’s ksdensity function. Distributions were computed in gray matter using the eroded tissue mask (see Section 2.3.2).
2.4.4. Spatial correlations between CVR parameter maps
CVR amplitude and delay maps for each reference signal were parcellated using FSL’s Harvard-Oxford cortical atlas in MNI space (https://identifiers.org/neurovault.collection:262, HarvardOxford-cortmaxprob-thr25–1 mm), resampled to 2.5 mm resolution. This atlas consists of 48 cortical parcels and was further split into left and right hemispheres to generate a total of 96 cortical parcels. Then, the median CVR parameter (i.e., amplitude or delay) within each parcel was computed. The 96 median values from any two corresponding CVR parameter maps (e.g., two CVR amplitude maps) were then input to determine “spatial” correlations (i.e., at the level of the parcels).
Two different types of spatial correlations were performed:
Inter-reference: Between CVR parameter maps from different reference signals, within the same subject and session (e.g., between PETCO2 CVR amplitude and RVT CVR amplitude for sub-002 ses-02),
Inter-quality: Between CVR parameter maps from datasets with sufficient PETCO2 quality and insufficient PETCO2 quality, for a given reference signal and subject (e.g., between a sufficient PETCO2 CVR amplitude map and an insufficient PETCO2 CVR amplitude map for sub-006).
For all spatial correlations, the Pearson correlation coefficients were computed and transformed to Fisher’s Z. A linear model was fitted, and the beta-coefficients describing the slope were extracted. The intercept of the linear model was allowed to vary for both CVR amplitude and delay to account for potential offsets between the two inputs.
3. Results
In the following sections, we first describe the reference signals from all datasets in our study and distinguish those with sufficient vs. insufficient quality. Then, we show inter-reference comparisons for datasets in which all three reference signals have sufficient quality. Next, we show inter-quality results (from two sessions) that incorporate one session with insufficient PETCO2 quality. Finally, we present the inter-reference comparisons from only sessions with insufficient PETCO2 quality. All comparisons are repeated for both CVR amplitude and CVR delay.
3.1. Reference signals
Table 2 summarizes relative power at the BH task frequency for PETCO2, RVT, and GM-BOLD in all datasets included in our study. We chose a subset of the available data, such that 16 datasets included in our study have sufficient PETCO2 quality, and 6 datasets have insufficient PETCO2 quality, with relative power below the 50% threshold and reaching as low as 4.33% (sub-009 ses-08). Across all datasets considered, insufficient PETCO2 traces have 21.1 ± 11.2% relative power (mean±stdev across subjects), while sufficient PETCO2 traces have 68.0 ± 6.57% relative power. Note that all RVT and GM-BOLD signals have greater than 50% relative power, with most far exceeding the threshold. Relative power in RVT and GM-BOLD signals is also generally higher than in PETCO2, with relative power at 86.6 ± 9.4% in RVT signals and 78.7 ± 8.4% in GM-BOLD signals.
Table 2.
Subject | Session | Classification of PETCO2 Quality | Relative Power (%) in BH Frequency Range (0.014 –0.020 Hz) |
||
---|---|---|---|---|---|
PETCO2 | RVT | GM-BOLD | |||
| |||||
sub-002 | ses-02 | Sufficient | 72.5 | 87.4 | 74.9 |
ses-03 | Sufficient | 56.5 | 90.2 | 69.2 | |
sub-003 | ses-02 | Sufficient | 69.5 | 88.7 | 87.2 |
ses-03 | Sufficient | 61.1 | 92.5 | 87.4 | |
sub-004 | ses-02 | Sufficient | 69.1 | 85.9 | 85.2 |
ses-03 | Sufficient | 73.9 | 54.1 | 84.7 | |
sub-006 | ses-02 | Sufficient | 81.5 | 87.0 | 83.3 |
ses-03 | Sufficient | 62.3 | 87.3 | 81.5 | |
ses-07 | Insufficient | 14.5 | 79.5 | 80.8 | |
ses-08 | Insufficient | 31.2 | 73.0 | 80.0 | |
sub-007 | ses-02 | Sufficient | 69.6 | 95.1 | 82.1 |
ses-03 | Sufficient | 73.7 | 94.8 | 85.7 | |
sub-008 | ses-02 | Sufficient | 61.5 | 87.2 | 79.5 |
ses-03 | Sufficient | 68.2 | 82.3 | 68.4 | |
sub-009 | ses-02 | Sufficient | 67.4 | 95.0 | 85.8 |
ses-03 | Sufficient | 74.5 | 94.6 | 86.7 | |
ses-08 | Insufficient | 4.33 | 94.0 | 85.4 | |
ses-09 | Insufficient | 18.2 | 91.1 | 77.3 | |
sub-010 | ses-02 | Sufficient | 66.4 | 88.5 | 56.1 |
ses-03 | Sufficient | 59.5 | 84.6 | 65.1 | |
ses-07 | Insufficient | 23.7 | 88.8 | 70.5 | |
ses-08 | Insufficient | 34.7 | 93.6 | 74.5 |
The PETCO2, RVT, and GM-BOLD signals for all datasets, in addition to group averages, are shown in Fig. 2. For sufficient PETCO2 traces as well as all RVT and GM-BOLD traces, there are clear peaks associated with each BH cycle (indicated by the gray bars). These signal changes are expected due to periods of apnea, which increase PETCO2 and elicit a cerebrovascular response that is detectable by BOLD fMRI. In contrast, the insufficient PETCO2 traces lack consistent peaks for each BH cycle, and the magnitude of PETCO2 changes is smaller. These signal characteristics likely indicate a failure to perform an exhalation before and after the BH, or exhalation through the mouth rather than the nose, which would not be captured by the nasal cannula. In these datasets, insufficient PETCO2 traces are not due to a failure to complete the BH task, because these subjects also have clear cyclic changes in their RVT signals, indicating long durations of a stable chest position (i.e., periods of apnea).
Fig. 2B illustrates the power spectra corresponding to the reference signals in Fig. 2A. The BH frequency range is indicated by a dashed rectangle, where most of the signal power is expected. There are clear peaks within this window for sufficient PETCO2 signals, as well as for all RVT and GM-BOLD signals. However, a peak within the BH frequency range is not evident for insufficient PETCO2 signals, which is consistent with the lack of periodic signal changes for each BH cycle in the time domain. These power spectra also support the low relative power reported for insufficient PETCO2 datasets in Table 2.
All reference signals are highly correlated in datasets with sufficient PETCO2, while correlations with insufficient PETCO2 timeseries are much lower. Relationships between each pair of reference signals were characterized by cross-correlations. These results are summarized in Supplementary Table S1. Datasets with sufficient PETCO2 have large, positive cross-correlation amplitudes for the three reference signal comparisons (reported as mean±stdev Fisher’s Z values across subjects): PETCO2 & RVT: 0.97±0.23, PETCO2 & GM-BOLD: 1.19±0.22, GM-BOLD & RVT: 1.08±0.20. As expected, cross-correlations of PETCO2 with RVT and GM-BOLD are lower in datasets with insufficient PETCO2, while the correlation between RVT and GM-BOLD is preserved (PETCO2 & RVT: 0.38±0.13, PETCO2 & GM-BOLD: 0.42±0.15, GM-BOLD & RVT: 1.20±0.22).
3.2. Sufficient PETCO2 datasets: CVR amplitude comparisons
3.2.1. Inter-reference comparisons
CVR amplitude maps are spatially similar for all reference signals, after accounting for differences in scale, in datasets with sufficient PETCO2 quality (Fig. 3). For each CVR map, the 98th percentile of CVR amplitude across all brain voxels was computed (Supplementary Table S3), and this magnitude was used as the positive and negative limits of the color scale. With this scaling method, the CVR amplitude maps look nearly identical, though there are small differences particularly in voxel clusters throughout WM and CSF regions. The same relative spatial patterns are observed in all maps: higher amplitudes in cortical GM, lower amplitudes in WM, and negative amplitudes in CSF-filled regions. However, it is important to draw attention to the fact that the absolute magnitude and units of these CVR amplitudes are different between methods. For example, the 98th percentile CVR amplitudes are 0.78±0.22 %BOLD/mmHg for PETCO2 CVR, 2.02±0.40 %BOLD/a.u. for RVT CVR, and 2.31±0.21 %BOLD/%BOLD for GM-BOLD CVR.
As expected from the qualitative similarity of the CVR amplitude maps, the distributions of CVR amplitude are similar across GM voxels for each method, though they span a different range of values (Fig. 4). For all reference signals, the distributions of CVR amplitude are consistent both within and between subjects. Note that it may not be appropriate to interpret the range of the CVR amplitude distributions, because only PETCO2 CVR amplitude is in meaningful units. Normalization of the RVT signal is critical to achieving these similarities in CVR amplitude, as the amplitude of the RVT measurement itself is arbitrary, with high variability even between two sessions of the same subject (see Supplementary Figure S1 and Table S2). Supplementary Figure S2 shows the distribution of CVR amplitudes without normalizing RVT and illustrates the impact on the resulting unscaled amplitude maps.
CVR amplitudes from each reference signal are highly correlated in datasets with sufficient PETCO2 quality. Fig. 5A shows the spatial correlations between CVR amplitude values generated by each reference signal (inter-reference correlations) and a visual comparison of these spatial correlations from session-to-session for each subject. The correlation coefficients, Fisher’s Z transformed correlations, and slopes for the lines-of-best fit are also summarized in Supplementary Table S4. All group average inter-reference spatial correlations are significantly different from zero (PETCO2 & RVT: Z = 2.15, p<0.001; PETCO2 & GM-BOLD: Z = 2.26, p<0.001; GM-BOLD & RVT: Z = 2.25, p<0.001). There is no significant difference between the strength of the CVR amplitude spatial correlations for each pairwise comparison between reference signals, based on a t-test adjusted for non-independent correlations (Howell, 2010) (PETCO2 & RVT vs. PET CO2 & GM-BOLD: T(13)=0.48, p = 0.64; PETCO2 & GM-BOLD vs. GM-BOLD & RVT: T(13)=0.01, p = 0.99; PETCO2 & RVT vs. GM-BOLD & RVT: T(13)=0.47, p = 0.65).
There is variability in the slope of the relationship between CVR amplitudes, with the best reliability between PETCO2 and RVT. In general, RVT and GM-BOLD CVR amplitudes are 2–3 times larger than for PETCO2 (average slopes of 2.42±0.65 for PETCO2 & RVT, 2.91±0.73 for PETCO2 & GM-BOLD). However, the magnitudes may not be meaningful due to the arbitrary units in RVT and GM-BOLD CVR. The reliability of these slopes was assessed with an intraclass correlation (using a two-way random effects model of absolute agreement), with the following results: ICC(2,1)=0.62 for PETCO2 & RVT, ICC(2,1)=0.44 for PETCO2 and GM-BOLD, and ICC(2,1)=0.41 for GM-BOLD and RVT. Thus, there is good reliability for PETCO2 & RVT CVR amplitudes, and fair reliability for the other inter-reference relationships. However, these estimates may be limited by the small number of repeated measurements and subjects.
3.3. Sufficient PETCO2 datasets: CVR delay comparisons
3.3.1. Inter-reference comparisons
The CVR delay maps generated by PETCO2 and RVT reference signals show similar spatial variation, while GM-BOLD delay maps have smaller delay magnitudes and reduced contrast, among datasets with sufficient PETCO2 quality (Fig. 6). Since CVR delay is expressed in quantitative units of seconds for all reference signals, CVR delay maps are centered around the GM median to fairly compare between reference signals. In general, PETCO2 and RVT delay maps characterize more extreme relative delays than GM-BOLD delay maps (indicated by more yellow and violet voxels throughout PETCO2 and RVT maps).
The distributions of CVR delay for each reference signal (Fig.7) support the observation that PETCO2 and RVT CVR delay maps show similar spatial variation while there is reduced contrast in GM-BOLD delay maps. The shape of PETCO2 and RVT delay distributions are generally similar: both are slightly right skewed and centered just below 0 s. On the other hand, GM-BOLD delay distributions are narrower and zero-centered, with a high proportion of voxels exhibiting delay values near 0 s. In addition, the GM-BOLD delay distributions are less smooth, with several small peaks apparent for some datasets (e.g., sub-003 ses-02, indicated by the orange trace). Finally, PETCO2 and RVT distributions are more variable between subjects, while GM-BOLD distributions have a relatively consistent shape.
The slopes of inter-reference relationships (Fig. 8A) further illustrate the narrower range of delays observed with the GM-BOLD reference signal (Figs 6 and 7). PETCO2 and RVT delay values are nearly proportional, with an average slope of 0.97±0.29. Excluding the outlier of sub-002 ses-02, the average slope becomes 1.01±−0.23. However, as demonstrated in the maps, GM-BOLD delay values tend to underestimate delay relative to PETCO2 and RVT. See middle and right columns of Fig. 8A, respectively, and note the switch in axes; this manifests as slopes < 1 for GM-BOLD with PETCO2 and slopes > 1 for GM-BOLD with RVT.
When comparing maps of CVR delay across the three reference signals (Fig. 8A), we see significant spatial correlations for all comparisons, although they are weaker on average compared to the spatial correlations of CVR amplitude (Fig. 5A). The corresponding spatial correlation coefficients, Fisher’s Z transformed correlations, and slopes for the lines-of-best fit are summarized in Supplementary Table S6. All group average inter-reference spatial correlations are significantly different from zero (PETCO2 & RVT: Z = 1.24, p<0.001; PETCO2 & GM-BOLD: Z = 1.35, p<0.001; GM-BOLD & RVT: Z = 1.12, p<0.001). There were no significant differences in the average spatial correlations between each pair of reference signals, based on a t -test adjusted for non-independent correlations (Howell, 2010) (PETCO2 & RVT vs. PETCO2 & GM-BOLD: T(13)=0.38, p = 0.72; PETCO2 & GM-BOLD vs. GM-BOLD & RVT: T(13)=0.92, p = 0.38; PETCO2 & RVT vs. GM-BOLD & RVT:T(13)=0.54, p = 0.60).
The slope of the relationship between CVR delay values from a given pair of reference signals is generally more consistent compared to CVR amplitudes, consistent with the common quantitative units (seconds) of CVR delay achieved with all three methods. This is demonstrated by the inter-subject consistency of slopes for each best-fit line in Fig. 8A. In addition, the inter-session reliability of the slopes was assessed with an intraclass correlation (using a two-way random effects model of absolute agreement). There is good reliability between PETCO2 and GM-BOLD delays (ICC(2,1) = 0.73) and between GM-BOLD and RVT delays (ICC(2,1)=0.63). However, there is poor reliability between PETCO2 and RVT delays (ICC(2,1)=0.35). As with CVR amplitude, these ICC estimates may be limited by the small number of repeated measurements and subjects.
To further characterize the bias of CVR delays estimated by RVT and GM-BOLD relative to PETCO2 delays, a Bland-Altman analysis was performed in each dataset with sufficient PETCO2 quality. On average, the differences in CVR delay are on the order of the shift increment used in our lagged-GLM approach (RVT=0.07±0.42 s; GM-BOLD=0.28±0.55 s). Additionally, 95% of all CVR delay differences fall within ±1.5 s for RVT (−1.38 to 1.45 s) and GM-BOLD (−1.40 to 0.83 s). More details on the Bland-Altman analysis and subject-level results can be found in Supplemental Material Section 3.1, Figure S3, and Table S8.
3.4. Insufficient PETCO2 datasets
3.4.1. Inter-quality comparisons
As described in Section 3.1, a total of 6 datasets were identified as having insufficient PETCO2 quality, based on the relative power content at the BH task frequency. Fig. 9 shows the reference signals, power spectra, and resulting CVR maps from datasets with sufficient and insufficient PETCO2 quality within the same example subject (inter-quality comparison). Not surprisingly, the CVR amplitude and delay maps generated by an insufficient PETCO2 timeseries do not show physiologically plausible spatial variations (Fig. 9B). Despite the insufficient task-related information within the PETCO2 timeseries, the RVT and GM-BOLD timeseries still demonstrate modulations consistent with the 8 cycles of the BH task and clear peaks in their power spectra. Therefore, consistent with our hypothesis, the resulting RVT and GM-BOLD CVR parameter maps are comparable to those from the dataset with sufficient PETCO2 quality.
The inter-quality spatial correlations between CVR parameter maps from insufficient and sufficient quality datasets support the qualitative observations in Fig. 9, in that the maps generated by RVT and GM-BOLD timeseries recover spatial information that is lost by those from the insufficient PETCO2 trace. For each reference signal’s CVR map from an insufficient PETCO2 session, a spatial correlation was performed with the respective parameter map from the first sufficient PETCO2 session (ses-02) in the same subject. Table 3 summarizes the Fisher’s Z transformed spatial correlation coefficients and the slope of the best-fit line between these data. When the reference signal is “insufficient PETCO2”, the average spatial correlations with a map computed using sufficient PETCO2 data acquired in a different scan session are not significant for either CVR amplitude (Z = 1.11±0.53) or CVR delay (Z = 0.25±0.53), using Zcrit =1.13 for N = 6 at alpha=0.05. In contrast, the inter-quality spatial correlations for RVT and GM-BOLD CVR amplitude and delay maps are significant between sufficient and insufficient datasets. This is expected, since the categorization of “sufficient” datasets was based on PETCO2 quality, with RVT and GM-BOLD signals surpassing the relative power criterion in all datasets.
Table 3.
Inter-quality spatial correlations | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Subject | Insufficient Session | Sufficient Session | CVR amplitude |
CVR delay |
||||||||||
PETCO2 |
RVT |
GM-BOLD |
PETCO2 |
RVT |
GM-BOLD |
|||||||||
β | Z | β | Z | β | Z | β | Z | β | Z | β | Z | |||
| ||||||||||||||
sub- | ses-07 | ses-02 | 1.30 | 1.73 | 1.18 | 1.83 | 1.00 | 1.88 | 0.43 | 0.54 | 0.67 | 0.94 | 0.60 | 0.90 |
006 | ses-08 | ses-02 | 0.98 | 1.22 | 1.04 | 1.55 | 1.01 | 1.70 | 0.44 | 0.46 | 0.62 | 1.07 | 0.77 | 1.23 |
sub- | ses-08 | ses-02 | 0.06 | 0.26 | 1.02 | 1.64 | 1.01 | 1.76 | −0.82 | 0.56 | 0.79 | 1.29 | 1.09 | 1.42 |
009 | ses-09 | ses-02 | 0.55 | 1.42 | 0.85 | 1.70 | 0.98 | 1.75 | 0.51 | 0.78 | 0.79 | 1.02 | 0.54 | 0.95 |
sub- | ses-07 | ses-02 | 0.98 | 0.74 | 1.05 | 1.44 | 0.93 | 1.66 | 0.29 | 0.71 | 0.75 | 1.49 | 0.79 | 1.20 |
010 | ses-08 | ses-02 | 1.15 | 1.30 | 1.12 | 1.38 | 1.19 | 1.67 | 0.63 | 1.17 | 0.68 | 1.25 | 0.81 | 1.59 |
| ||||||||||||||
Average | 0.84 | 1.11 | 1.04 | 1.59* | 1.02 | 1.74* | 0.25 | 0.70 | 0.72 | 1.18* | 0.77 | 1.21* | ||
StDev | 0.46 | 0.53 | 0.11 | 0.17 | 0.09 | 0.08 | 0.53 | 0.26 | 0.07 | 0.21 | 0.19 | 0.26 |
β = coefficient of slope for best-fit line to correlation. Z = Fisher’s Z transformation of correlation coefficient.
Indicates Fisher’s Z is significantly different from 0 at alpha = 0.05 (critical Z = 1.13 for N = 6).
However, it is important to note the differences in PETCO2 CVR maps are not as dramatic for all datasets with insufficient PETCO2 quality. These maps are presented in Supplementary Figure S4. Specifically, amplitude maps from some insufficient PETCO2 traces have reasonable quality, while the delay maps remain noisy. For example, the CVR amplitude maps obtained with insufficient PETCO2 are similar to those obtained with RVT and GM-BOLD for sub-006 ses-07, sub-009 ses09, and sub-010 ses-08. These datasets also have higher inter-quality spatial correlations, as indicated by the Fisher’s Z values in Table 3. The relative power in the insufficient PETCO2 signals for these three datasets (Table 2) far exceeds the relative power of 4.33% in the example case highlighted in Fig. 9, indicating that there may have been some sufficient BH trials to generate reasonably good CVR amplitude maps. While some insufficient PETCO2 CVR amplitude maps are similar, the CVR de-lay maps still have noticeable regional differences (e.g., more negative delays and reduced tissue contrast), though less extreme than shown in Fig. 9.
3.4.2. Inter-reference comparisons
Similarly, the inter-reference spatial correlations within each insufficient PETCO2 dataset demonstrate the corrupted CVR amplitude and CVR delay maps generated by the PETCO2 traces (Supplementary Table S10). Correlations of PETCO2 CVR amplitude with RVT and GM-BOLD CVR amplitude are expectedly lower (Z = 1.44±0.73 and Z = 1.41±0.69, respectively) compared to those between GM-BOLD and RVT (Z = 2.56±0.13), which still have sufficient power at the task frequency. This difference is especially apparent in sub-009 ses-08 and sub-010 ses-07. The same pattern of low spatial correlations with results derived from PETCO2 is evident in the CVR delay values (Z = 0.75±0.38 for correlation of delays with insufficient PETCO2 and RVT; Z = 0.66±0.37 with insufficient PETCO2 and GM-BOLD; Z = 1.34±0.22 with RVT and GM-BOLD).
4. Discussion
In this study, we tested whether RVT or GM-BOLD can be used in a lagged-GLM framework to achieve estimates of CVR amplitude and delay that are spatially correlated with estimates from PETCO2. We tested this in breath-hold data in healthy adults, including datasets where PETCO2, RVT, and GM-BOLD reference signals had sufficient power (> 50%) at the task frequency, and datasets where only the PETCO2 timeseries had insufficient power. We found that in datasets with sufficient quality, all reference signals are highly correlated. Correspondingly, CVR amplitude maps are spatially similar for all reference signals, after accounting for differences in scale. However, both RVT and GM-BOLD CVR amplitudes are not in standard CVR units of %BOLD/mmHg. Regarding CVR delay, the maps generated by PETCO2 and RVT show similar spatial variation, while GM-BOLD delay maps have a smaller range and reduced contrast. Finally, when PETCO2 is insufficient, RVT and GM-BOLD can be used to recover spatially similar CVR amplitude and delay maps, provided that the participant attempted the breath-hold task. We explore each of these findings in further detail in the following sections.
4.1. Reference signals are highly correlated in breath-hold data with sufficient PETCO2 quality
The high cross-correlation amplitudes observed between PETCO2, RVT, and GM-BOLD signals are expected and consistent with previous reports in the literature. Each of these signals captures the physiological processes occurring during a breath-hold, marked by a cessation of breathing, increased arterial CO2 concentration, increased CBF, and an increased BOLD signal that eventually returns to baseline (Bright et al., 2009; Kastrup et al., 1999; Thomason et al., 2005). PETCO2 and RVT have separately been shown to correlate with the resting-state BOLD timeseries (Birn et al., 2008, 2006; Wise et al., 2004). Additionally, PETCO2 and RVT (convolved with the respiration response function) are highly correlated and account for similar spatial and temporal variations in the resting-state BOLD signal (Chang and Glover, 2009).
In breath-hold data, these cross-correlations are magnified due to the alternating periods of task and rest, which lead to large coupled amplitude fluctuations in PETCO2, RVT, and GM-BOLD that are approximately sinusoidal at the task frequency (Pinto et al., 2021). These quasisinusoidal variations are critical to our approach for determining sufficient PETCO2 based on relative power at the task frequency. While this strategy can be easily implemented to quality check PETCO2 recordings, it requires periodic breathing modulation and thus cannot easily be translated to evaluate the quality of natural PETCO2 fluctuations in resting-state data.
The reference signals we considered are not exhaustive. The nearsinusoidal fluctuations in the BOLD response during a quasi-periodic breath-hold task can be modeled using a Fourier series, with a sinecosine pair at the task frequency and additional harmonics, to estimate both CVR amplitude and delay (Lipp et al., 2015; Murphy et al., 2011; Pinto et al., 2016; van Niftrik et al., 2016). Additionally, many studies use different variations of a global BOLD signal to model CVR, rather than a respiratory-derived signal, due to the known influence of arterial CO2 fluctuations on the BOLD signal (Geranmayeh et al., 2015; Liu et al., 2017; Tong et al., 2011; Tong and Frederick, 2014; van Niftrik et al., 2016). As we have demonstrated with GM-BOLD, there are clear breath-hold effects in the average BOLD response, leading to CVR measurements that are comparable to those derived from PETCO2.
4.2. CVR amplitude maps are comparable between reference signals, but RVT and GM-BOLD amplitudes are not in standard CVR units
Based on the high cross-correlations between input reference signals, it is not surprising that the resulting CVR amplitude maps are also highly correlated. In fact, CVR maps from each reference signal look nearly identical when scaled to the 98th percentile CVR amplitude. Regardless of the method used to model CVR, this visualization scaling approach may facilitate qualitative comparisons of CVR maps, longitudinally, between cohorts, and between protocols. Our CVR visualization approach also indicates the method used to model CVR may not be critical for qualitative comparisons, which is consistent with the current ethos regarding the “multiverse” of analysis pipelines in the functional neuroimaging community (Botvinik-Nezer et al., 2020; Dafflon et al., 2022; Steegen et al., 2016; Taylor et al., 2022).
Despite the qualitative similarities between CVR maps, there are important differences in the absolute magnitudes of CVR amplitude. Both RVT and GM-BOLD CVR are not in standard CVR units, which is an important caveat, particularly for comparing CVR between cohorts or with literature values. In these cases, it is still best to use PETCO2 as a reference signal, because the resulting CVR amplitude in units of %BOLD/mmHg is physiologically meaningful. There is also between-subject variability in the slope of the relationship between CVR amplitudes, likely driven in part by the arbitrary units of RVT and GM-BOLD CVR. Overall, RVT CVR had the most reliable relationship with PETCO2 CVR amplitude, suggesting that this might be a better alternative than GM-BOLD to capture differences in CVR amplitude.
However, our results indicate that RVT and GM-BOLD would still be useful in many cases, such as making relative comparisons between brain regions within a subject and identifying focal pathology. In addition, the CVR maps for RVT and GM-BOLD were consistent between scan sessions (Appendix A). With these steady measurements, it could be possible to compare longitudinally within a subject, provided that a breath-hold task is used to induce modulations and there is sufficient power at the task frequency.
We observed that normalizing the RVT timeseries before inputting it to the lagged-GLM is critical to achieve reasonable CVR amplitude values. RVT is reported in arbitrary units (a.u.) because the magnitude of RVT varies across experimental setups and is sensitive to the tightness of the respiration belt and its placement on the body (i.e., chest vs. abdomen). Thus, there is high variability in the scale of RVT fluctuations across datasets (Supplementary Fig. S1 and Table S2). The resulting CVR amplitude maps are impacted by this variability because they are scaled to the amplitude of the reference signal. If RVT is not normalized, there are large differences in the range of amplitude values, which could be misleading if CVR maps are plotted on a fixed scale (Supplementary Fig. S2).
4.3. CVR delay maps are comparable for PETCO2 and RVT, but GM-BOLD may underestimate delay variability
In datasets with sufficient PETCO2 quality, RVT and GM-BOLD both produce delay maps that are highly correlated with those from PETCO2. However, there are differences in the consistency between delay maps for some subjects, particularly between PETCO2 and RVT (Figs. 6 and 7). These differences may be attributed to lower relative power in the input reference signals, particularly if the PETCO2 trace is closer to the 50% threshold. The response functions we used to model PETCO2 and RVT might not be optimal for the breath-hold response, potentially introducing differences in CVR delay with regional patterns (see Section 4.8). More subtle physiological contributions may also play a role, since intra-thoracic pressure, heart rate, neural activity patterns, and other factors that influence the BOLD signal may be time-locked to the breath-hold task with different spatial signatures.
Delay magnitudes also tend to be smaller when GM-BOLD is the reference signal. This is evident in the narrower distributions of GM-BOLD delay values (Fig. 7) and in the biased slopes from inter-reference spatial correlations with PETCO2 and RVT delays (Fig. 8A). Thus, GM-BOLD may underestimate the true delay value, particularly for voxels with larger absolute PETCO2 delays. This may be influenced by our decision to normalize delay maps to the GM median to compare between reference signals and participants. Many GM voxels will be well-characterized by the average BOLD timeseries and have similar delay values that are reduced to zero after this spatial normalization step. Additionally, the GM-BOLD signal (after the T2-weighted combination of the echoes) might be more affected by motion-related effects than other reference signals (Moia et al., 2021). For example, peaks or slow drifts in the GM-BOLD timeseries due to head motion could bias the optimum delay estimated for a given voxel. More likely, the GM-BOLD signal is “blurring” the breath-hold response due to the wide variation in relative timing across the brain (Tong et al., 2019). This has been addressed previously with the concept of making a “refined” or “dynamic” global signal regressor that accounts for voxel-specific variations in delay to recover a source signal (Erdoğan et al., 2016; Frederick et al., 2012; Tong and Frederick, 2014). Our approach using the average response across GM voxels is well-established but more simplistic and may have restricted the sensitivity to a wider range of delays. An average signal from the cerebellum (Donahue et al., 2016; Liu et al., 2021), sagittal sinus (Pillai and Mikulis, 2015; van Niftrik et al., 2016), or other small ROIs (Erdo ğan et al., 2016) could also be used to mitigate this issue. However, the cerebellum is sensitive to noise (Diedrichsen et al., 2010; van der Zwaag et al., 2015) and these ROIs are arbitrary for CVR analysis.
To address limitations attributed to the GM-BOLD regressor, we performed a post hoc exploratory analysis to compare CVR delays using a “refined” GM-BOLD approach. The refined GM-BOLD regressor used in this analysis was generated by Rapidtide v2.2.7, a data-driven algorithm that uses the refined GM-BOLD timeseries as a regressor, for which it iteratively considers a voxel-by-voxel fit across a range of temporal offsets using a cross-correlation method (Frederick et al., 2012, 2016). We considered a temporal range of ±9 s with 0.3 s increments to match the lagged-GLM (specific command options are detailed in Table S11, and we refer the reader to the Rapidtide documentation (Frederick et al., 2022a) to explore more in-depth details about the settings). This algorithm further differs from the lagged-GLM processing method by also temporally smoothing the average GM-BOLD response with a band-pass filter (0.009–0.15 Hz) and “despeckling” using a spatial median filter to correct erroneous time delays due to autocorrelation in the probe regressor (Frederick, 2017). Additionally, motion parameters and Legendre polynomials are regressed from the data before the cross-correlation fit, in contrast to being included in the lagged-GLM. Fig. 10 shows a comparison between the original GM-BOLD approach and a refined GM-BOLD approach for a representative subject (sub-008). Results for all subjects with sufficient PETCO2 data quality can be found in Supplementary (Figures S6–S10, Table S12). The refined GM-BOLD regressor is similar to the GM-BOLD time series yet smoother, with high frequencies removed (Fig. 10A).
CVR delay maps generated using the refined GM-BOLD approach depict greater visual contrast between gray matter and white matter in comparison to the CVR delay maps generated with the average GM-BOLD approach (Fig. 10B). Furthermore, the distribution of delays generated from a CVR delay map using the refined GM-BOLD approach show a skewness towards larger positive delays (Fig. 10C). The delay values from both methods are highly correlated and the slopes of the spatial correlations are greater than 1, indicating that the refined GM-BOLD approach depicts more extreme delays across most of the cortex in comparison to the GM-BOLD approach (Fig. 10D). Thus, using a refined GM-BOLD timeseries as a regressor may partially compensate for the smaller distribution in delays attributed to the lagged-GLM with a standard GM-BOLD timeseries.
4.4. When PETCO2 quality is insufficient, maps of CVR amplitude and delay can be achieved with RVT or GM-BOLD as reference signals
We have demonstrated that in breath-hold fMRI data, if a participant attempts the task but PETCO2 quality is poor, RVT or GM-BOLD can be used to create CVR amplitude and delay maps. Based on comparisons with sufficient PETCO2 quality data, RVT seems the best alternative to generate CVR amplitude and delay maps that are highly correlated and have consistent relationships with those obtained with PETCO2 measurements. In addition, RVT still generates CVR measurements that are normalized to a respiratory-derived measure. If opting for a global signal like GM-BOLD, it would be best to use a refined GM-BOLD regressor to account for potential under-estimation of CVR delay.
We also proposed a method to define a “sufficient” PETCO2 trace for CVR mapping, using a relative power threshold >50% at the breath-hold task frequency. However, this threshold is slightly arbitrary and may need to be adjusted for specific cases, with a holistic evaluation of reference signals and their resulting CVR amplitude and delay maps. In fact, some of the datasets with insufficient PETCO2 still showed reasonably good CVR amplitude maps (Fig. S4). However, the corresponding CVR delay maps are less similar to those generated by sufficient quality timeseries and should give cause for caution when interpreting the CVR amplitude maps, due to potential mis-fitting of the reference signal. For example, there are several regions of negative CVR amplitudes in the map for sub-010 ses-07 (indicated by blue voxels in the corresponding map of Fig. S4), which resemble the vascular “steal” phenomenon and could be mis-characterized as pathology (Conklin et al., 2010; Poublanc et al., 2013; Sam et al., 2016). Therefore, insufficient PETCO2 CVR maps should be interpreted carefully, particularly in clinical cases.
Although these are promising results to recover CVR maps retrospectively or in low resource settings, we still recommend trying to obtain sufficient PETCO2 estimates from a breathing modulation for the highest quality CVR maps. There are suggestions throughout the literature on how to implement robust breath-hold tasks (Bright and Murphy, 2013; Murphy et al., 2011; Pinto et al., 2021; Scouten and Schwarzbauer, 2008; Urback et al., 2017). In brief, it is strongly recommended to incorporate a training session before the scan to ensure that participants understand and comply with task instructions (Kannurpatti et al., 2010; Magon et al., 2009; Zacà et al., 2014). Monitoring respiratory signals throughout the task is also encouraged to ensure quality of the recording and assess task performance (Bulte and Wartolowska, 2017). In addition, cueing strategies (e.g., text, symbolic, or auditory) should be carefully considered to make instructions intuitive for the target population. Lastly, other breathing tasks might be more feasible than a breath-hold, such as intermittent breath modulation (Liu et al., 2020) or paced deep breathing (Bright et al., 2009; Sousa et al., 2014; Stickland et al., 2021). With these alternative methods, a similar approach to determine relative power at the task frequency could still be implemented, though the limitations of extending our findings to other breathing modulations are discussed in Section 4.7.
4.5. Potential impacts and examples of utility
The use of alternative reference signals to generate CVR amplitude and delay maps has a range of potential impacts. The framework proposed here using RVT or GM-BOLD reference signals makes prospective CVR mapping accessible to any imaging centers that lack the equipment and personnel necessary to monitor and post-process respiratory gas recordings. A respiration belt should be integrated with most scanning set-ups, and the GM-BOLD signal requires no additional monitoring. All lagged-GLM regression analyses, with the exception of the RVT computation, are based on open-source software (peakdet, phys2cvr, and rapidtide) to facilitate the modeling steps for future applications. In addition, these findings present the opportunity to retrospectively generate CVR maps in breath-hold data where PETCO2 data was not collected or had insufficient quality.
Potentially most impactful, a method to acquire robust CVR amplitude and delay maps even in datasets with insufficient PETCO2 quality has important implications for populations where it may be difficult to obtain reliable end-tidal measurements. This includes children, where previous work has demonstrated reasonable task compliance but poor PETCO2 quality, either due to mouth breathing or failure to perform end-exhales. It also includes aging cohorts and clinical populations (both pediatric and adults), who may similarly have difficulty following the steps needed for sufficient quality PETCO2 (Handwerker et al., 2007; Thomason et al., 2005). However, further systematic comparisons are necessary for translation of these methods in other cohorts (see Section 4.7).
Overall, improved accessibility to CVR mapping can increase the prevalence of this informative metric of vascular health. Several reviews have described the utility of CVR mapping for understanding disease mechanisms and as a biomarker to triage patients for therapeutic interventions and track the efficacy of these interventions (Blair et al., 2015; Gupta et al., 2012; Juttukonda and Donahue, 2019; Pillai and Mikulis, 2015; Sleight et al., 2021; Smeeing et al., 2016). Aside from clinical populations, CVR mapping is also recommended in healthy cohorts to isolate differences in the BOLD response that may be due to differences in vascular rather than neural processes (Handwerker et al., 2007; Thomason et al., 2007; Tsvetanov et al., 2015).
4.6. Limitations of generalizability
The comparisons laid out in this study are valid only for breath-hold task fMRI data in healthy individuals. Further optimization and testing are needed to determine if these alternative reference signals can be used for CVR mapping with other populations and experimental designs. It is unclear if this framework can be generalized to clinical populations, and particularly those with cerebrovascular pathology. We highlight key limitations to the generalizability of our proposed framework below.
First, there are several limitations of RVT as a reference signal. Because RVT is not a quantitative measure, it does not account for variability in the voluntary control of ventilation, including neuronal control, breath-hold depths, ventilatory rate, and breathing patterns (e.g., abdominal vs. thoracic). Therefore, RVT-based measurements may have limited sensitivity to inter-session CVR differences and may be inappropriate for clinical populations with altered respiratory control, such as those with autonomic nervous system dysfunction (Weese-Mayer et al., 2006). Furthermore, RVT and the RRF have not been systematically optimized for modeling breath-holds and may need to be revised for this purpose (see Section 4.7). Power et al. (2020) have also demonstrated that RVT is less sensitive to some respiratory events in resting-state fMRI data compared to other respiratory metrics derived from belt recordings (envelope of the waveform, respiration variation). These metrics may also be more sensitive in breath-hold data.
In addition, there are limitations to using GM-BOLD as a reference signal in any cohort where BOLD response patterns might be atypical, such as in cerebrovascular disease or healthy aging. For example, in certain pathologies, the average gray matter signal may be biased by regions with atypical perfusion dynamics. This could be addressed by averaging across normal-appearing tissue, or by using global signal refinement procedures as described in Section 4.3 (Frederick et al., 2012, 2016), which correct for wide delay ranges. However, in conditions where most gray matter regions are affected, these procedures may not be sufficient to correct the GM-BOLD signal and using it as a reference may lead to inaccurate estimates of CVR amplitude and delay.
Additionally, careful consideration should be given to the lagged-GLM approach and interpretation of CVR delay values in participants with cerebrovascular pathology. Using the lagged-GLM approach, hemodynamic delays in the range of ±9 s are consistently reported for healthy individuals (Bright et al., 2009; Donahue et al., 2016; Moia et al., 2021, 2020a; Sousa et al., 2014; Stickland et al., 2021), while in a case of unilateral moyamoya, delays exceeded 10 s in the affected hemisphere (Stickland et al., 2021). The delay range used in the lagged-GLM should be modified to reflect those that are physiologically plausible for a given condition. Hemodynamic delays on the order of 10 to 20 s have also been reported in other pathologies, including steno-occlusive, small vessel disease, and dementia (Atwi et al., 2019; Duffin et al., 2015; Hartkamp et al., 2012; Holmes et al., 2020; McKetton et al., 2019; Thrippleton et al., 2018). In these conditions, the expected delays are an order of magnitude larger than the bias introduced by using RVT or GM-BOLD as reference signals, relative to the gold standard of PETCO2 (RVT = 0.07±0.42 s; GM-BOLD = 0.28±0.55 s, Table S8). See Supplementary Section 3.1 for more details on this Bland-Altman error analysis. However, in some pathologies, differences in CVR delay may be more subtle and on the same scale of these inter-reference errors. Thus, the framework proposed here is likely to be more appropriate in cases where hemodynamic delays are more extreme.
It is also important to acknowledge that our dataset is exceptional in terms of participant compliance and signal quality. All participants attempted the breath-hold task with repeated periods of apnea. The respiration belt recordings successfully captured these changes in chest position, which are necessary to generate an RVT signal that has sufficient power at the task frequency. Similarly, the periods of apnea are required to induce a rise in arterial CO2 levels and the successive increase in CBF detected by the GM-BOLD signal. Achieving this level of task compliance could be difficult in some cohorts, although there is a breadth of literature demonstrating successful use of breath-hold tasks (Pinto et al., 2021; Urback et al., 2017). The GM-BOLD signal used in our study also benefits from the boost in SNR achieved from the optimal combination of 5 echoes (Cohen and Wang, 2019; Moia et al., 2021). If a multi-echo fMRI approach is not feasible, spatial smoothing or cortical parcellation could be used as alternatives to boost SNR at the cost of spatial definition. CVR maps from any reference signal will also be influenced by the quality of the input fMRI data, from acquisition to the pre-processing and denoising steps applied (Caballero-Gaudes and Reynolds, 2017). As with all fMRI acquisitions, we recommend mitigating motion confounds during the scan and modeling these noise sources in the lagged-GLM (Moia et al., 2021).
Lastly, the alternative reference signals considered here may not be highly correlated with PETCO2 in paced deep breathing tasks and may have insufficient variability in resting state to produce reasonable CVR maps. Using a paced hyperventilation task to induce hypocapnia, Vogt et al. (2011) found that RVT convolved with the respiration response function was less strongly correlated to BOLD signal changes than PETCO2 convolved with an empirically derived response function. They conjectured that the uncoupling of the signals was due to the higher rate of CO2 reduction during hyperventilation relative to the slower rate of metabolic CO2 production, which is captured by the PETCO2 regressor but not in the canonical respiration response (Vogt et al., 2011). This could potentially be addressed with optimization of the respiration response function for hypocapnia.
4.7. Alternative approaches to address compliance challenges in CVR mapping
While we ideally recommend using a breathing task and respiratory-derived signal for CVR mapping, alternative methods without end-tidal CO2 recordings or in resting-state have been proposed to address the challenges associated with breathing tasks. These methods are reviewed in detail by Pinto et al., 2021, but we discuss key comparisons. As described in Section 4.4, the Rapidtide algorithm can generate a probe regressor from the global BOLD signal or another reference timeseries and use temporal cross-correlation with each voxel timeseries to determine maximum correlations and corresponding time delays (Frederick et al., 2016) (Tong and Frederick, 2014). The correlation metrics are surrogates for CVR, although the outputs are not in the standard CVR units (%BOLD/mmHg) that allow for comparison across subjects, particularly if the global signal is used as the probe. With a PETCO2 probe, the Rapidtide outputs could potentially be modified to obtain CVR amplitude in normalized units.
From resting-state data, the global BOLD signal can be bandpass filtered to approximate arterial CO2 fluctuations and used as a regressor to estimate CVR (Liu et al., 2017). In addition, resting-state metrics such as the amplitude of low frequency fluctuations (ALFF) or fractional ALFF (fALFF) have demonstrated high correlations with CVR derived from CO2 challenges (Di et al., 2013; Golestani et al., 2016; Kazan et al., 2016). However, this relationship is controversial (Moia et al., 2022a). For instance, in the same dataset used in this study, Moia et al. (2022a) shows that resting-state metrics (RSFA, ALFF, fALFF) have highly variable inter-subject relationships with breath-hold CVR measures.
Additionally, the lagged-GLM has been previously performed with PETCO2 from resting-state data, but the delay optimization procedure was less successful, leading to noisy estimates of CVR amplitude and delay (Stickland et al., 2021). This was hypothesized to be due to the smaller fluctuations in the resting-state signal relative to a breathing task and the confounds of low-frequency oscillations from neural activity and other physiological processes that may disrupt the optimization procedure (Caballero-Gaudes and Reynolds, 2017; Liu, 2016; Murphy et al., 2013). The increased BOLD sensitivity and data quality associated with the multi-echo acquisition in our study also helps to improve the CVR estimates (Moia et al., 2021). Similar results would be expected for alternative resting-state reference signals.
Although these alternative methods provide some insight into cerebrovascular physiology, each is missing a key characteristic of robust CVR measurements. Namely, none of these methods simultaneously use a breathing modulation to challenge the vascular system, normalize the BOLD changes to a reference signal that accounts for variability in breathing task performance, and correct for regional delays in CVR response time (Stickland et al., 2021).
4.8. Future work
CVR map quality and accuracy could be further improved by refining the response functions used to model the effects of PETCO2 and respiration fluctuations on the BOLD signal. We assumed canonical response functions for the HRF (Friston et al., 1998) and RRF (Birn et al., 2008) used to model PETCO2 and RVT, respectively. However, the BOLD response to PETCO2 fluctuations may exhibit a slightly different temporal pattern than the canonical HRF (Golestani et al., 2015; Vogt et al., 2011). While we have accounted for regional variations in the timing of these responses, we have not incorporated flexible response shapes. Spatial heterogeneity in the amplitude and timing of BOLD responses to respiratory variation is apparent in resting-state data, with notable differences between primary sensory regions and frontoparietal regions (Chen et al., 2020; Pinto et al., 2017). The inclusion of basis sets in the lagged-GLM as described by Chen et al., 2020 may better account for this variability.
In addition, response functions have been shown to vary between subjects and even between sessions from the same subject (Kassinopoulos and Mitsis, 2019). Kassinopoulos and Mitsis (2019) proposed a framework to estimate subject-specific response functions by using a combination of optimization techniques to estimate parameters of the double gamma functions, which could also be implemented to generate more accurate reference signals. Similarly, they could be estimated from the subject-specific global or GM-BOLD signals (Falahpour et al., 2013), but importantly the estimated response functions should be tested in other datasets to avoid circularity. Regardless of the approach, differences in response functions are especially important to consider in cohorts that may have atypical hemodynamics, as in older adults and cerebrovascular pathology (D’Esposito et al., 2003). Future work should re-evaluate consistency between CVR maps with region-specific and/or subject-specific response functions.
We encourage collaboration among stakeholders in the CVR community and suggest integration among the existing approaches that aim to address the feasibility of physiological modeling and CVR mapping. For example, a refined GM-BOLD regressor could be extracted from existing algorithms such as Rapidtide (Frederick et al., 2022b) or seeVR (Bhogal, 2022) and incorporated into the lagged-GLM. Alternatively, standard implementations of CVR modeling algorithms, including Rapidtide, seeVR, and quantiphyse (Craig et al., 2022), could be modified to input RVT as a reference signal if not already supported. Machine learning may also be a promising tool to address challenges with reference signal quality. For example, Agrawal et al., 2022 successfully used the respiratory waveform in resting-state data to predict CO2 and derive PETCO2 using a fully convolutional neural network (Agrawal et al., 2022). However, their method does not maintain PET CO2 in quantitative units of mmHg either, which would be preferred for modeling CVR amplitude. A separate study proposed two deep learning architectures (again a convolutional neural network and a fully connected single-unit network) to reconstruct respiratory variation signals from the fMRI data itself (Salas et al., 2021). Future work could adapt these models to predict a “sufficient” PETCO2 trace from insufficient PETCO2 data, from a respiration trace, or from the fMRI data in the context of a breath-hold task. This would be especially promising if the algorithm is able to scale the resulting PETCO2 signal in standard units (i.e., %BOLD/mmHg).
5. Conclusion
End-tidal CO2 (PETCO2) is commonly used as a reference signal to facilitate modeling of cerebrovascular reactivity (CVR) in BOLD fMRI data, but the PETCO2 recordings may be unavailable or unreliable in many settings. We demonstrate that respiration volume per time (RVT) or the average gray matter BOLD response during a breath-hold task can be used in a lagged general linear model framework to obtain estimates of CVR amplitude and delay. Furthermore, CVR maps from these reference signals have good spatial agreement with those from the gold standard reference of PETCO2. In datasets with sub-optimal or “insufficient” PETCO2 recordings, RVT and GM-BOLD can also be used to recover reasonable CVR amplitude and delay maps, provided that the participant achieved periods of apnea during the breath-hold task. This framework offers a solution to obtain non-quantitative CVR amplitude and quantitative delay maps when reliable PETCO2 recordings are unavailable due to limitations in resources or participant compliance.
Supplementary Material
Acknowledgments
The authors would like to thank Andrew Vigotsky for his feedback on the visualizations in this manuscript.
Funding
This research was supported by the European Union’s Horizon 2020 research and innovation program (Marie Skłodowska-Curie grant agreement No. 713673), a fellowship from La Caixa Foundation (ID 100010434, fellowship code LCF/BQ/IN17/11620063), the Spanish Ministry of Economy and Competitiveness (Ramon y Cajal Fellowship, RYC-2017-21845), the Spanish State Research Agency (BCBL “Severo Ochoa” excellence accreditation, SEV-2015-490), the Basque Government (BERC 2018-2021 and PIBA_2019_104), the Spanish Ministry of Science, Innovation and Universities (MICINN; PID2019-105520GB-100 and FJCI-2017-31814). K.M.Z. was supported by the National Institutes of Health under a training program (T32EB025766) and by the National Heart, Lung, And Blood Institute under Award Number F31HL166079. The content is solely the responsibility of the authors and does not necessarily represent the official views of the National Institutes of Health.
Abbreviation:
- CVR
cerebrovascular reactivity
- BOLD
blood oxygenation level dependent
- BH
breath-hold
- PETCO2
partial pressure of end-tidal CO2
- RVT
respiration volume per time
- GM
gray matter
- GM-BOLD
average gray matter BOLD response
- fMRI
functional magnetic resonance imaging
- HRF
hemodynamic response function
- RRF
respiration response function
Appendix A: Consistency of CVR amplitude and delay maps between sessions
The consistency of CVR parameter maps was evaluated by performing “inter-session” spatial correlations. These correlations were performed between CVR parameter maps from two consecutive sessions, for a given subject and reference signal (e.g., between PETCO2 CVR amplitude maps from ses-02 and ses-03 for sub-002). The same methods described in Section 2.4.4 for “inter-reference” and “inter-quality” spatial correlations were applied here. In brief, CVR maps were parcellated into 96 cortical parcels. The median values from each parcel were input into spatial correlations. Pearson correlation coefficients were computed and transformed to Fisher’s Z. A linear model was also fitted to determine the slope of the relationship.
CVR amplitude inter-session comparisons: For all reference signals, the resulting CVR amplitude maps are highly similar between sessions, provided there was sufficient PETCO2 data in each subject. Inter-session spatial correlations were similar for each reference signal with no significant differences in average Fisher’s Z across subjects (PETCO2: Z = 1.62, RVT: Z = 1.50, GM-BOLD: Z = 1.75). The inter-session spatial correlations are depicted in Fig. A.1 and summarized in Supplementary Table S5. There is nearly a 1:1 relationship in the CVR amplitude maps between consecutive sessions for each reference signal (average slopes: PETCO2 = 1.00±0.23, RVT = 0.91±0.26, GM-BOLD=0.95±0.07). Excluding the outlier of sub-006, the average slope for RVT increases to 0.97±0.21.
CVR delay inter-session comparisons: CVR delay maps for each reference signal are also highly spatially correlated between two consecutive sessions, provided the PETCO2 quality was sufficient. These inter-session spatial correlations for CVR delay are summarized in Fig. A.2 and Supplementary Table S7. There were no significant differences in average Fisher’s Z across subjects (PETCO2: Z = 1.11, RVT: Z = 1.14, GM-BOLD: Z = 1.21). The average slope between delays from consecutive sessions is also similar for each reference signal (average slope for PETCO2: 0.83±0.22, RVT: 0.81±0.21, GM-BOLD: 0.87±0.11).
Refined GM-BOLD inter-session comparisons: The between-scan consistency of Refined GM-BOLD delay maps (described in Discussion Section 4.3) was also evaluated for comparison to GM-BOLD. While the delay maps generated from the Refined GM-BOLD signal are highly similar across sessions (Z = 0.99±0.32), the inter-session spatial correlations are lower relative to GM-BOLD (Z = 1.21±0.19). However, these correlations were not statistically different in average Fisher’s Z, and sub-003 may be an outlier reducing the average Refined GM-BOLD correlation (Z = 1.07±0.23 without sub-003). The Refined GM-BOLD inter-session spatial correlations are visualized in Supplementary Fig. S10, and Supplementary Table S13 summarizes these correlations.
Footnotes
Declaration of Competing Interest
The authors declare no competing financial interests.
Credit authorship contribution statement
Kristina M. Zvolanek: Conceptualization, Methodology, Software, Formal analysis, Data curation, Writing – original draft, Writing – review & editing, Visualization, Project administration, Funding acquisition. Stefano Moia: Conceptualization, Methodology, Software, Formal analysis, Resources, Data curation, Writing – review & editing, Funding acquisition. Joshua N. Dean: Software, Formal analysis, Writing – original draft, Writing – review & editing, Visualization. Rachael C. Stickland: Software, Methodology, Writing – review & editing. César Caballero-Gaudes: Conceptualization, Methodology, Resources, Writing – review & editing, Funding acquisition. Molly G. Bright: Conceptualization, Methodology, Resources, Writing – review & editing, Supervision, Project administration, Funding acquisition.
Supplementary materials
Supplementary material associated with this article can be found, in the online version, at doi:10.1016/j.neuroimage.2023.120038.
Data and code availability statement
(Included verbatim in Methods Section 2.3) The MRI images and physiological data used in this study are available on OpenNeuro at doi:10.18112/openneuro.ds003192.v1.0.1 (Moia, Uruñuela, Ferrer, & Caballero-Gaudes, 2020). All code for preprocessing of the MRI data has been prepared to be run in a Singularity container, which is publicly available at https://git.bcbl.eu/smoia/euskalibur_container. The pre-processing pipeline is available at https://github.com/smoia/EuskalIBUR_preproc. Publicly available Python scripts, peakdet (Markello & DuPre, 2020) and phys2cvr (Moia, Vigotsky, & Zvolanek, 2022), were used for processing of CO2 recordings and computation of CVR parameter maps. The open-source Rapidtide v2.2.7 toolbox (B. deB Frederick, Salo, & Drucker, 2022) was used for exploratory analysis (see Discussion Section 4.3). Additional analysis code and details about how they were implemented for this manuscript are shared in the public GitHub repository: https://github.com/BrightLab-ANVIL/Zvolanek_2022.
References
- Agrawal V, Zhong XZ, Chen JJ, Chen J, 2022. Generating dynamic carbon-dioxide from the respiratory-volume time series: a feasibility study using neural networks. bioRxiv 2022 07 (11), 499585. doi: 10.1101/2022.07.11.499585. [DOI] [Google Scholar]
- Andersson JLR, Skare S, Ashburner J, 2003. How to correct susceptibility distortions in spin-echo echo-planar images: application to diffusion tensor imaging. Neuroimage 20, 870–888. doi: 10.1016/S1053-8119(03)00336-7. [DOI] [PubMed] [Google Scholar]
- Atwi S, Shao H, Crane DE, da Costa L, Aviv RI, Mikulis DJ, Black SE, MacIntosh BJ, 2019. BOLD-based cerebrovascular reactivity vascular transfer function isolates amplitude and timing responses to better characterize cerebral small vessel disease. NMR Biomed. 32, e4064. doi: 10.1002/NBM.4064. [DOI] [PubMed] [Google Scholar]
- Bhogal AA, 2022. abhogal-lab/seeVR: 1.5. doi: 10.5281/ZENODO.6532362. [DOI] [Google Scholar]
- Birn RM, Diamond JB, Smith MA, Bandettini PA, 2006. Separating respiratory-variation-related fluctuations from neuronal-activity-related fluctuations in fMRI. Neuroimage 31, 1536–1548. doi: 10.1016/j.neuroimage.2006.02.048. [DOI] [PubMed] [Google Scholar]
- Birn RM, Smith MA, Jones TB, Bandettini PA, 2008. The respiration response function: the temporal dynamics of fMRI signal fluctuations related to changes in respiration. Neuroimage 40, 644–654. doi: 10.1016/j.neuroimage.2007.11.059. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Blair GW, Doubal FN, Thrippleton MJ, Marshall I, Wardlaw JM, 2015. Magnetic resonance imaging for assessment of cerebrovascular reactivity in cerebral small vessel disease: a systematic review. J. Cereb. Blood Flow Metab. 36, 833–841. doi:. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Botvinik-Nezer R, Holzmeister F, Camerer CF, Dreber A, Huber J, Johannesson M, Kirchler M, Iwanir R, Mumford JA, Adcock RA, Avesani P, Baczkowski BM, Bajracharya A, Bakst L, Ball S, Barilari M, Bault N, Beaton D, Beitner J, Benoit RG, Berkers RMWJ, Bhanji JP, Biswal BB, Bobadilla-Suarez S, Bortolini T, Bottenhorn KL, Bowring A, Braem S, Brooks HR, Brudner EG, Calderon CB, Camilleri JA, Castrellon JJ, Cecchetti L, Cieslik EC, Cole ZJ, Collignon O, Cox RW, Cunningham WA, Czoschke S, Dadi K, Davis CP, Luca A, De, Delgado MR, Demetriou L, Dennison JB, Di X, Dickie EW, Dobryakova E, Donnat CL, Dukart J, Duncan NW, Durnez J, Eed A, Eickhoff SB, Erhart A, Fontanesi L, Fricke GM, Fu S, Galván A, Gau R, Genon S, Glatard T, Glerean E, Goeman JJ, Golowin SAE, González-García C, Gorgolewski KJ, Grady CL, Green MA, Guassi Moreira JF, Guest O, Hakimi S, Hamilton JP, Hancock R, Handjaras G, Harry BB, Hawco C, Herholz P, Herman G, Heunis S, Hoffstaedter F, Hogeveen J, Holmes S, Hu CP, Huettel SA, Hughes ME, Iacovella V, Iordan AD, Isager PM, Isik AI, Jahn A, Johnson MR, Johnstone T, Joseph MJE, Juliano AC, Kable JW, Kassinopoulos M, Koba C, Kong XZ, Koscik TR, Kucukboyaci NE, Kuhl BA, Kupek S, Laird AR, Lamm C, Langner R, Lauharatanahirun N, Lee H, Lee S, Leemans A, Leo A, Lesage E, Li F, Li MYC, Lim PC, Lintz EN, Liphardt SW, Losecaat Vermeer AB, Love BC, Mack ML, Malpica N, Marins T, Maumet C, McDonald K, McGuire JT, Melero H, Méndez Leal AS, Meyer B, Meyer KN, Mihai G, Mitsis GD, Moll J, Nielson DM, Nilsonne G, Notter MP, Olivetti E, Onicas AI, Papale P, Patil KR, Peelle JE, Pérez A, Pischedda D, Poline JB, Prystauka Y, Ray S, Reuter-Lorenz PA, Reynolds RC, Ricciardi E, Rieck JR, Rodriguez-Thompson AM, Romyn A, Salo T, Samanez-Larkin GR, Sanz-Morales E, Schlichting ML, Schultz DH, Shen Q, Sheridan MA, Silvers JA, Skagerlund K, Smith A, Smith DV, Sokol-Hessner P, Steinkamp SR, Tashjian SM, Thirion B, Thorp JN, Tinghög G, Tisdall L, Tompson SH, Toro-Serey C, Torre Tresols JJ, Tozzi L, Truong V, Turella L, van ‘t Veer AE, Verguts T, Vettel JM, Vijayarajah S, Vo K, Wall MB, Weeda WD, Weis S, White DJ, Wisniewski D, Xifra-Porxas A, Yearling EA, Yoon S, Yuan R, Yuen KSL, Zhang L, Zhang X, Zosky JE, Nichols TE, Poldrack RA, Schonberg T, 2020. Variability in the analysis of a single neuroimaging dataset by many teams. Nat. 2020 5827810 (582), 84–88. doi: 10.1038/s41586-020-2314-9. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Bright MG, Bulte DP, Jezzard P, Duyn JH, 2009. Characterization of regional heterogeneity in cerebrovascular reactivity dynamics using novel hypocapnia task and BOLD fMRI. Neuroimage 48, 166–175. doi: 10.1016/j.neuroimage.2009.05.026. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Bright MG, Murphy K, 2013. Reliable quantification of BOLD fMRI cerebrovascular reactivity despite poor breath-hold performance. Neuroimage doi: 10.1016/j.neuroimage.2013.07.007. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Bulte D, Wartolowska K, 2017. Monitoring cardiac and respiratory physiology during FMRI. Neuroimage 154, 81–91. doi: 10.1016/j.neuroimage.2016.12.001. [DOI] [PubMed] [Google Scholar]
- Caballero-Gaudes C, Reynolds RC, 2017. Methods for cleaning the BOLD fMRI signal. Neuroimage 154, 128–149. doi: 10.1016/j.neuroimage.2016.12.018. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Cauley SF, Polimeni JR, Bhat H, Wald LL, Setsompop K, 2014. Interslice leakage artifact reduction technique for simultaneous multislice acquisitions. Magn. Reson. Med. 72, 93–102. doi: 10.1002/MRM.24898. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Chang C, Glover GH, 2009. Relationship between respiration, end-tidal CO2, and BOLD signals in resting-state fMRI. Neuroimage 47, 1381–1393. doi: 10.1016/j.neuroimage.2009.04.048. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Chang C, Thomason ME, Glover GH, 2008. Mapping and correction of vascular hemodynamic latency in the BOLD signal. Neuroimage 43, 90–102. doi: 10.1016/J.NEUROIMAGE.2008.06.030. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Chen JE, Lewis LD, Chang C, Tian Q, Fultz NE, Ohringer NA, Rosen BR, Polimeni JR, 2020. Resting-state “physiological networks. Neuroimage 213, 116707. doi: 10.1016/j.neuroimage.2020.116707. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Cohen AD, Wang Y, 2019. Improving the assessment of breath-holding induced cerebral vascular reactivity using a multiband multi-echo ASL/BOLD Sequence. Sci. Rep. 9, 1–12. doi: 10.1038/s41598-019-41199-w. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Conklin J, Fierstra J, Crawley AP, Han JS, Poublanc J, Mandell DM, Silver FL, Tymianski M, Fisher JA, Mikulis DJ, 2010. Impaired cerebrovascular reactivity with steal phenomenon is associated with increased diffusion in white matter of patients with moyamoya disease. Stroke 41, 1610–1616. doi: 10.1161/STROKEAHA.110.579540/FORMAT/EPUB. [DOI] [PubMed] [Google Scholar]
- Cox RW, 1996. AFNI: software for analysis and visualization of functional magnetic resonance neuroimages. Comput. Biomed. Res. 29, 162–173. doi: 10.1006/CBMR.1996.0014. [DOI] [PubMed] [Google Scholar]
- Craig M, Irving B, Chappell M, Croal P, Zhao M, 2022. physimals/quantiphysev0.9.9 [WWW Document]. URL https://quantiphyse.readthedocs.io/en/latest/index.html (accessed 10.10.22).
- D’Esposito M, Deouell LY, Gazzaley A, 2003. Alterations in the BOLD fMRI signal with ageing and disease: a challenge for neuroimaging. Nat. Rev. Neurosci. 2003 411 (4), 863–872. doi: 10.1038/nrn1246. [DOI] [PubMed] [Google Scholar]
- Dafflon J, Da Costa F, Váš a P, Monti F, Bzdok RP, Hellyer D, Turkheimer PJ, Smallwood F, Jones J, E, Leech R., 2022. A guided multiverse study of neuroimaging analyses. Nat. Commun. 2022 131 13, 1–13. doi: 10.1038/s41467-022-31347-8. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Di X, Kim EH, Huang CC, Tsai SJ, Lin CP, Biswal BB, 2013. The influence of the amplitude of low-frequency fluctuations on resting-state functional connectivity. Front. Hum. Neurosci. 0, 118. doi: 10.3389/FNHUM.2013.00118/BIBTEX. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Diedrichsen J, Verstynen T, Schlerf J, Wiestler T, 2010. Advances in functional imaging of the human cerebellum. Curr. Opin. Neurol. 23, 382–387. doi: 10.1097/WCO.0B013E32833BE837. [DOI] [PubMed] [Google Scholar]
- Dlamini N, Shah-Basak P, Leung J, Kirkham F, Shroff M, Kassner A, Robertson A, Dirks P, Westmacott R, De Veber G, Logan W, 2018. Breath-hold blood oxygen level-dependent MRI: a tool for the assessment of cerebrovascular reserve in children with moyamoya disease. Am. J. Neuroradiol. 39, 1717–1723. doi: 10.3174/ajnr.A5739. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Donahue MJ, Dethrage LM, Faraco CC, Jordan LC, Clemmons P, Singer R, Mocco J, Shyr Y, Desai A, O’Duffy A, Riebau D, Hermann L, Connors J, Kirshner H, Strother MK, 2014. Routine clinical evaluation of cerebrovascular reserve capacity using carbogen in patients with intracranial stenosis. Stroke 45, 2335–2341. doi: 10.1161/STROKEAHA.114.005975. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Donahue MJ, Strother MK, Lindsey KP, Hocke LM, Tong Y, Frederick BDB, 2016. Time delay processing of hypercapnic fMRI allows quantitative parameterization of cerebrovascular reactivity and blood flow delays. J. Cereb. Blood Flow Metab. 36, 1767–1779. doi:. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Duffin J, Sobczyk O, Crawley AP, Poublanc J, Mikulis DJ, Fisher JA, 2015. The dynamics of cerebrovascular reactivity shown with transfer function analysis. Neuroimage 114, 207–216. doi: 10.1016/j.neuroimage.2015.04.029. [DOI] [PubMed] [Google Scholar]
- DuPre E, Salo T, Ahmed Z, Bandettini PA, Bottenhorn KL, Caballero-Gaudes C, Dowdle LT, Gonzalez-Castillo J, Heunis S, Kundu P, Laird AR, Markello R, Markiewicz CJ, Moia S, Staden I, Teves JB, Uruñuela E, Vaziri-Pashkam M, Whitaker K, Handwerker DA, 2021. TE-dependent analysis of multi-echo fMRI with *tedana*. J. Open Source Softw. 6, 3669. doi: 10.21105/JOSS.03669. [DOI] [Google Scholar]
- DuPre E, Salo T, Markello R, Kundu P, Whitaker K, Handwerker D, 2019. ME-ICA/tedana: 0.0.6. 10.5281/ZENODO.2558498. [DOI] [Google Scholar]
- Erdoğan SB, Tong Y, Hocke LM, Lindsey KP, deB Frederick B, 2016. Correcting for blood arrival time in global mean regression enhances functional connectivity analysis of resting state fMRI-BOLD signals. Front. Hum. Neurosci. 10, 311. doi: 10.3389/FN-HUM.2016.00311/BIBTEX. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Falahpour M, Refai H, Bodurka J, 2013. Subject specific BOLD fMRI respiratory and cardiac response functions obtained from global signal. Neuroimage 72, 252–264. doi: 10.1016/j.neuroimage.2013.01.050. [DOI] [PubMed] [Google Scholar]
- Fierstra J, Sobczyk O, Battisti-Charbonney A, Mandell DM, Poublanc J, Crawley AP, Mikulis DJ, Duffin J, Fisher JA, 2013. Measuring cerebrovascular reactivity: what stimulus to use? J. Physiol. 591, 5809–5821. doi: 10.1113/jphysiol.2013.259150. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Fierstra J, van Niftrik C, Piccirelli M, Bozinov O, Pangalu A, Krayenbühl N, Valavanis A, Weller M, Regli L, 2018. Diffuse gliomas exhibit whole brain impaired cerebrovascular reactivity. Magn. Reson. Imaging 45, 78–83. doi: 10.1016/J.MRI.2017.09.017. [DOI] [PubMed] [Google Scholar]
- Frederick B, de B, Nickerson LD, Tong Y, 2012. Physiological denoising of BOLD fMRI data using regressor interpolation at progressive time delays (RIPTiDe) processing of concurrent fMRI and near-infrared spectroscopy (NIRS). Neuroimage 60, 1913–1923. doi: 10.1016/J.NEUROIMAGE.2012.01.140. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Frederick B deB., Salo T., Drucker DM., 2016. Rapidtide. doi: 10.5281/zenodo.814990. [DOI] [Google Scholar]
- de B Frederick, B., 2017. bbfrederick/rapidtide: december 2017 checkpoint release. doi: 10.5281/ZENODO.1119128. [DOI] [Google Scholar]
- Frederick B de B, Salo T., Drucker DM., 2022a. bbfrederick/rapidtide: version 2.2.7 – 6/29/22 checkpoint. doi: 10.5281/ZENODO.6780450. [DOI] [Google Scholar]
- Frederick B deB, Salo T., Drucker DM., 2022b. bbfrederick/rapidtide: version 2.2.8.1 – 8/29/22 deployment bug fix. doi: 10.5281/ZENODO.7032879. [DOI] [Google Scholar]
- Friston KJ, Fletcher P, Josephs O, Holmes A, Rugg MD, Turner R, 1998. Event-related fMRI: characterizing differential responses. Neuroimage 7, 30–40. doi: 10.1006/nimg.1997.0306. [DOI] [PubMed] [Google Scholar]
- Geranmayeh F, Wise RJS, Leech R, Murphy K, 2015. Measuring vascular reactivity with breath-holds after stroke: a method to aid interpretation of group-level BOLD signal changes in longitudinal fMRI studies. Hum. Brain Mapp. 36, 1755–1771. doi: 10.1002/hbm.22735. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Golestani AM, Chang C, Kwinta JB, Khatamian YB, Jean Chen J, 2015. Mapping the end-tidal CO2 response function in the resting-state BOLD fMRI signal: spatial specificity, test-retest reliability and effect of fMRI sampling rate. Neuroimage 104, 266–277. doi: 10.1016/j.neuroimage.2014.10.031. [DOI] [PubMed] [Google Scholar]
- Golestani AM, Wei LL, Chen JJ, 2016. Quantitative mapping of cerebrovascular reactivity using resting-state BOLD fMRI: validation in healthy adults. Neuroimage 138, 147–163. doi: 10.1016/j.neuroimage.2016.05.025. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Gorgolewski KJ, Auer T, Calhoun VD, Craddock RC, Das S, Duff EP, Flandin G, Ghosh SS, Glatard T, Halchenko YO, Handwerker DA, Hanke M, Keator D, Li X, Michael Z, Maumet C, Nichols BN, Nichols TE, Pellman J, Poline JB, Rokem A, Schaefer G, Sochat V, Triplett W, Turner JA, Varoquaux G, Poldrack RA, 2016. The brain imaging data structure, a format for organizing and describing outputs of neuroimaging experiments. Sci. Data 2016 31 3, 1–9. doi: 10.1038/sdata.2016.44. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Grabner G, Janke AL, Budge MM, Smith D, Pruessner J, Collins DL, 2006. Symmetric atlasing and model based segmentation: an application to the hippocampus in older adults. Lect. Notes Comput. Sci. (including Subser. Lect. Notes Artif. Intell. Lect. Notes Bioinformatics) 4191, 58–66. doi: 10.1007/11866763_8/COVER, LNCS-II. [DOI] [PubMed] [Google Scholar]
- Gupta A, Chazen JL, Hartman M, Delgado D, Anumula N, Shao H, Mazumdar M, Segal AZ, Kamel H, Leifer D, Sanelli PC, 2012. Cerebrovascular reserve and stroke risk in patients with carotid stenosis or occlusion: a systematic review and meta-analysis. Stroke 43, 2884–2891. doi: 10.1161/STROKEAHA.112.663716/-/DC1. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Halchenko Y, Goncalves M, Castello MV, di O.., Ghosh S, Hanke M., Dae, Salo T, Kent J, Amlien I, Brett M, Tilley S, Markiewicz C, Gorgolewski C, pvelasco, Kim S, Stadler J, Kaczmarzyk J, Lukas DC, lee, john, Lurie D, Pellman J, Braun H, Melo B, Poldrack B, Nichols T, Schiffler B, Szczepanik M, Carlin J, Feingold F, Kahn A, 2019. nipy/heudiconv v0.6.0. doi: 10.5281/ZENODO.3579455. [DOI] [Google Scholar]
- Handwerker DA, Gazzaley A, Inglis BA, D’Esposito M, 2007. Reducing vascular variability of fMRI data across aging populations using a breathholding task. Hum. Brain Mapp. 28, 846–859. doi: 10.1002/hbm.20307. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Hartkamp NS, Hendrikse J, Van Der Worp HB, De Borst GJ, Bokkers RPH, 2012. Time course of vascular reactivity using repeated phase-contrast MR angiography in patients with carotid artery stenosis. Stroke 43, 553–556. doi: 10.1161/STROKEAHA.111.637314. [DOI] [PubMed] [Google Scholar]
- Holmes KR, Tang-Wai D, Sam K, Mcketton L, Poublanc J, Crawley AP, Sobczyk O, Cohn M, Duffin J, Tartaglia MC, Black SE, Fisher JA, Wasserman B, Mikulis DJ, 2020. Slowed temporal and parietal cerebrovascular response in patients with alzheimer’s disease. Can. J. Neurol. Sci. 47, 366–373. doi: 10.1017/CJN.2020.30. [DOI] [PubMed] [Google Scholar]
- Howell DC, 2010. Testing the difference between two independent rs. Stat. Methods Psychol. 275–276. [Google Scholar]
- Jenkinson M, Bannister P, Brady M, Smith S, 2002. Improved optimization for the robust and accurate linear registration and motion correction of brain images. Neuroimage 17, 825–841. doi: 10.1006/NIMG.2002.1132. [DOI] [PubMed] [Google Scholar]
- Jenkinson M, Beckmann CF, Behrens TEJ, Woolrich MW, Smith SM, 2012. FSL. Neuroimage 62, 782–790. doi: 10.1016/J.NEUROIMAGE.2011.09.015. [DOI] [PubMed] [Google Scholar]
- Jenkinson M, Smith S, 2001. A global optimisation method for robust affine registration of brain images. Med. Image Anal. 5, 143–156. doi: 10.1016/S1361-8415(01)00036-6. [DOI] [PubMed] [Google Scholar]
- Juttukonda MR, Donahue MJ, 2019. Neuroimaging of vascular reserve in patients with cerebrovascular diseases. Neuroimage doi: 10.1016/j.neuroimage.2017.10.015. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Kannurpatti SS, Motes MA, Rypma B, Biswal BB, 2010. Neural and vascular variability and the fMRI-BOLD response in normal aging. Magn. Reson. Imaging 28, 466–476. doi: 10.1016/j.mri.2009.12.007. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Kassinopoulos M, Mitsis GD, 2019. Identification of physiological response functions to correct for fluctuations in resting-state fMRI related to heart rate and respiration. Neuroimage 202, 116150. doi: 10.1016/j.neuroimage.2019.116150. [DOI] [PubMed] [Google Scholar]
- Kastrup A, Krüger G, Neumann-Haefelin T, Moseley ME, 2001. Assessment of cerebrovascular reactivity with functional magnetic resonance imaging: comparison of CO2 and breath holding. Magn. Reson. Imaging 19, 13–20. doi: 10.1016/S0730-725X(01)00227-2. [DOI] [PubMed] [Google Scholar]
- Kastrup A, Li T−Q, Glover, G.H., Moseley ME., 1999. Cerebral blood flow-related signal changes during breath-holding. AJNR Am. J. Neuroradiol. 20, 1233–1238. [PMC free article] [PubMed] [Google Scholar]
- Kazan SM, Mohammadi S, Callaghan MF, Flandin G, Huber L, Leech R, Kennerley A, Windischberger C, Weiskopf N, 2016. Vascular autorescaling of fMRI (VasA fMRI) improves sensitivity of population studies: a pilot study. Neuroimage 124, 794–805. doi: 10.1016/J.NEUROIMAGE.2015.09.033. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Krainik A, Hund-Georgiadis M, Zysset S, Yves Von Cramon D., 2005. Regional impairment of cerebrovascular reactivity and BOLD signal in adults after stroke. doi: 10.1161/01.STR.0000166178.40973.a7. [DOI] [PubMed] [Google Scholar]
- Leung J, Duffin J, Fisher JA, Kassner A, 2016a. MRI-based cerebrovascular reactivity using transfer function analysis reveals temporal group differences between patients with sickle cell disease and healthy controls. NeuroImage Clin. 12, 624–630. doi: 10.1016/j.nicl.2016.09.009. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Leung J, Kosinski PD, Croal PL, Kassner A, 2016b. Developmental trajectories of cerebrovascular reactivity in healthy children and young adults assessed with magnetic resonance imaging. J. Physiol. 594, 2681–2689. doi: 10.1113/JP271056. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Lipp I, Murphy K, Caseras X, Wise RG, 2015. Agreement and repeatability of vascular reactivity estimates based on a breath-hold task and a resting state scan. Neuroimage 113, 387–396. doi: 10.1016/J.NEUROIMAGE.2015.03.004. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Liu P, De Vis JB, Lu H, 2019. Cerebrovascular reactivity (CVR) MRI with CO2 challenge: a technical review. Neuroimage 187, 104–115. doi: 10.1016/j.neuroimage.2018.03.047. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Liu P, Li Y, Pinho M, Park DC, Welch BG, Lu H, 2017. Cerebrovascular reactivity mapping without gas challenges. Neuroimage 146, 320–326. doi: 10.1016/j.neuroimage.2016.11.054. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Liu P, Liu G, Pinho MC, Lin Z, Thomas BP, Rundle M, Park DC, Huang J, Welch BG, Lu H, 2021. Cerebrovascular reactivity Mapping using resting-state bold functional MRI in healthy adults and patients with moyamoya disease. Radiology 299, 419–425. doi: 10.1148/RADIOL.2021203568/ASSET/IMAGES/LARGE/RADIOL.2021203568.FIG6.JPEG. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Liu P, Xu C, Lin Z, Sur S, Li Y, Yasar S, Rosenberg P, Albert M, Lu H, 2020. Cerebrovascular reactivity mapping using intermittent breath modulation. Neuroimage 215, 116787. doi: 10.1016/j.neuroimage.2020.116787. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Liu TT, 2016. Noise contributions to the fMRI signal: an overview. Neuroimage 143, 141–151. doi: 10.1016/J.NEUROIMAGE.2016.09.008. [DOI] [PubMed] [Google Scholar]
- Magon S, Basso G, Farace P, Ricciardi GK, Beltramello A, Sbarbati A, 2009. Reproducibility of BOLD signal change induced by breath holding. Neuroimage 45, 702–712. doi: 10.1016/j.neuroimage.2008.12.059. [DOI] [PubMed] [Google Scholar]
- Marshall O, Lu H, Brisset JC, Xu F, Liu P, Herbert J, Grossman RI, Ge Y, 2014. Impaired cerebrovascular reactivity in multiple sclerosis. JAMA Neurol. 71, 1275–1281. doi: 10.1001/jamaneurol.2014.1668. [DOI] [PMC free article] [PubMed] [Google Scholar]
- McKetton L, Sobczyk O, Duffin J, Poublanc J, Sam K, Crawley AP, Venkatraghavan L, Fisher JA, Mikulis DJ, 2018. The aging brain and cerebrovascular reactivity. Neuroimage 181, 132–141. doi: 10.1016/j.neuroimage.2018.07.007. [DOI] [PubMed] [Google Scholar]
- McKetton L, Venkatraghavan L, Rosen C, Mandell DM, Sam K, Sobczyk O, Poublanc J, Gray E, Crawley A, Duffin J, Fisher JA, Mikulis D, 2019. Improved white matter cerebrovascular reactivity after revascularization in patients with stenoocclusive disease. Am. J. Neuroradiol. 40, 45–50. doi: 10.3174/ajnr.A5912. [DOI] [PMC free article] [PubMed] [Google Scholar]
- McSwain SD, Hamel DS, Smith PB, Gentile MA, Srinivasan S, Meliones JN, Cheifetz IM, 2010. End-tidal and arterial carbon dioxide measurements correlate across all levels of physiologic dead space. Respir. Care 55, 288–293. [PMC free article] [PubMed] [Google Scholar]
- Mikulis DJ, Krolczyk G, Desal H, Logan W, DeVeber G, Dirks P, Tymianski M, Crawley A, Vesely A, Kassner A, Preiss D, Somogyi R, Fisher JA, 2005. Preoperative and postoperative mapping of cerebrovascular reactivity in moyamoya disease by using blood oxygen level-dependent magnetic resonance imaging. J. Neurosurg. 103, 347–355. doi: 10.3171/jns.2005.103.2.0347. [DOI] [PubMed] [Google Scholar]
- Moia S, Chen G, Urunuela E, Stickland R, Termenon M, Caballero-Gaudes C, Bright M, 2022a. Resting state fluctuations in BOLD fMRI might not systematically reflect measures of cerebrovascular physiology between or within subjects, in: International Society of Magnetic Resonance in Medicine (ISMRM) 31st Annual Meeting & Exhibition. London, England, UK. [Google Scholar]
- Moia S, Stickland RC, Ayyagari A, Termenon M, Caballero-Gaudes C, Bright MG, 2020a. Voxelwise optimization of hemodynamic lags to improve regional CVR estimates in breath-hold fMRI. Proc. Annu. Int. Conf. IEEE Eng. Med. Biol. Soc. EMBS 2020-July 1489–1492. doi: 10.1109/EMBC44109.2020.9176225. [DOI] [PubMed] [Google Scholar]
- Moia S, Termenon M, Uruñuela E, Chen G, Stickland RC, Bright MG, Caballero-Gaudes C, 2021. ICA-based denoising strategies in breath-hold induced cerebrovascular reactivity mapping with multi echo BOLD fMRI. Neuroimage 233, 117914. doi: 10.1016/J.NEUROIMAGE.2021.117914. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Moia S, Uruñuela E, Ferrer V, Caballero-Gaudes C, 2020b. EuskalIBUR. OpenNeuro. doi: 10.18112/OPENNEURO.DS003192.V1.0.1. [DOI] [Google Scholar]
- Moia S, Vigotsky AD, Zvolanek KM, 2022b. Physiopy/phys2cvr: a tool to compute cerebrovascular reactivity maps and associated lag maps. doi: 10.5281/ZENODO.7336002. [DOI] [Google Scholar]
- Murphy K, Birn RM, Bandettini PA, 2013. Resting-state fMRI confounds and cleanup. Neuroimage 80, 349–359. doi: 10.1016/j.neuroimage.2013.04.001. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Murphy K, Harris AD, Wise RG, 2011. Robustly measuring vascular reactivity differences with breath-hold: normalising stimulus-evoked and resting state BOLD fMRI data. Neuroimage 54, 369–379. doi: 10.1016/j.neuroimage.2010.07.059. [DOI] [PubMed] [Google Scholar]
- Peebles K, Celi L, McGrattan K, Murrell C, Thomas K, Ainslie PN, 2007. Human cerebrovascular and ventilatory CO2 reactivity to end-tidal, arterial and internal jugular vein PCO2. J. Physiol. 584, 347–357. doi: 10.1113/JPHYSIOL.2007.137075. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Pillai JJ, Mikulis DJ, 2015. Cerebrovascular reactivity mapping: an evolving standard for clinical functional imaging. Am. J. Neuroradiol. doi: 10.3174/ajnr.A3941 [DOI] [PMC free article] [PubMed] [Google Scholar]
- Pinto J, Bright MG, Bulte DP, Figueiredo P, 2021. Cerebrovascular Reactivity Mapping Without Gas Challenges: a Methodological Guide. Front. Physiol. 11, 1711. doi: 10.3389/fphys.2020.608475. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Pinto J, Jorge J, Sousa I, Vilela P, Figueiredo P, 2016. Fourier modeling of the BOLD response to a breath-hold task: optimization and reproducibility. Neuroimage 135, 223–231. doi: 10.1016/J.NEUROIMAGE.2016.02.037. [DOI] [PubMed] [Google Scholar]
- Pinto J, Nunes S, Bianciardi M, Dias A, Silveira LM, Wald LL, Figueiredo P, 2017. Improved 7 Tesla resting-state fMRI connectivity measurements by cluster-based modeling of respiratory volume and heart rate effects. Neuroimage 153, 262. doi: 10.1016/J.NEUROIMAGE.2017.04.009. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Posse S, Wiese S, Gembris D, Mathiak K, Kessler C, Grosse-Ruyken M−L, Elghahwagi B., Richards T., Dager SR., Kiselev, V G., 1999. Enhancement of BOLD-contrast sensitivity by single-shot multi-echo functional MR Imaging. Magn. Reson. Med. 42, 87–97. doi: 10.1002/(SICI)1522-2594(199907)42:1. [DOI] [PubMed] [Google Scholar]
- Poublanc J, Show J, Daniel H, Mandell M, Conklin J, Stainsby JA, Arnold J, David F, Mikulis J, Crawley AP, 2013. vascular steal explains early paradoxical blood oxygen level-dependent cerebrovascular response in brain regions with delayed arterial transit times. Cerebrovasc. Dis. Extra 3, 55–64. doi: 10.1159/000348841. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Power JD, Lynch CJ, Dubin MJ, Silver BM, Martin A, Jones RM, 2020. Characteristics of respiratory measures in young adults scanned at rest, including systematic changes and “missed” deep breaths. Neuroimage 204, 116234. doi: 10.1016/j.neuroimage.2019.116234. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Pujol J, Conesa G, Deus J, López-Obarrio L, Isamat F, Capdevila A, 1998. Clinical application of functional magnetic resonance imaging in presurgical identification of the central sulcus. J. Neurosurg. 88, 863–869. doi: 10.3171/JNS.1998.88.5.0863. [DOI] [PubMed] [Google Scholar]
- Salas JA, Bayrak RG, Huo Y, Chang C, 2021. Reconstruction of respiratory variation signals from fMRI data. Neuroimage 225, 117459. doi: 10.1016/j.neuroimage.2020.117459. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Sam K, Conklin J, Holmes KR, Sobczyk O, Poublanc J, Crawley AP, Mandell DM, Venkatraghavan L, Duffin J, Fisher JA, Black SE, Mikulis DJ, 2016. Impaired dynamic cerebrovascular response to hypercapnia predicts development of white matter hyperintensities. NeuroImage Clin. 11, 796–801. doi: 10.1016/J.NICL.2016.05.008. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Schouwenaars IT, De Dreu MJ, Rutten GJM, Ramsey NF, Jansma JM, 2021. A functional MRI study of presurgical cognitive deficits in glioma patients. Neuro-Oncol. Pract. 8, 81–90. doi: 10.1093/NOP/NPAA059. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Scouten A, Schwarzbauer C, 2008. Paced respiration with end-expiration technique offers superior BOLD signal repeatability for breath-hold studies. Neuroimage 43, 250–257. doi: 10.1016/j.neuroimage.2008.03.052. [DOI] [PubMed] [Google Scholar]
- Sleight E, Stringer MS, Marshall I, Wardlaw JM, Thrippleton MJ, 2021. Cerebrovascular reactivity measurement using magnetic resonance imaging: a systematic review. Front. Physiol. doi: 10.3389/fphys.2021.643468. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Smeeing DPJ, Hendrikse J, Petersen ET, Donahue MJ, de Vis JB, 2016. Arterial spin labeling and blood oxygen level-dependent MRI cerebrovascular reactivity in cerebrovascular disease: a systematic review and meta-analysis. Cerebrovasc. Dis. 42, 288–307. doi: 10.1159/000446081. [DOI] [PubMed] [Google Scholar]
- Sotiropoulos SN, Moeller S, Jbabdi S, Xu J, Andersson JL, Auerbach EJ, Yacoub E, Feinberg D, Setsompop K, Wald LL, Behrens TEJ, Ugurbil K, Lenglet C, 2013. Effects of image reconstruction on fiber orientation mapping from multichannel diffusion MRI: reducing the noise floor using SENSE. Magn. Reson. Med. 70, 1682–1689. doi: 10.1002/MRM.24623. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Sousa I, Vilela P, Figueiredo P, 2014. Reproducibility of hypocapnic cerebrovascular reactivity measurements using BOLD fMRI in combination with a paced deep breathing task. Neuroimage 98, 31–41. doi: 10.1016/j.neuroimage.2014.04.049. [DOI] [PubMed] [Google Scholar]
- Steegen S, Tuerlinckx F, Gelman A, Vanpaemel W, 2016. Increasing transparency through a multiverse analysis. Perspect. Psychol. Sci. 11, 702–712. doi: 10.1177/1745691616658637/ASSET/IMAGES/LARGE/10.1177_1745691616658637-FIG2.JPEG. [DOI] [PubMed] [Google Scholar]
- Stickland RC, Zvolanek KM, Moia S, Ayyagari A, Caballero-Gaudes C, Bright MG, 2021. A practical modification to a resting state fMRI protocol for improved characterization of cerebrovascular function. Neuroimage 239, 118306. doi: 10.1016/j.neuroimage.2021.118306. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Taylor PA, Reynolds RC, Calhoun V, Gonzalez-Castillo J, Handwerker DA, Bandettini PA, Mejia AF, Chen G, 2022. Highlight results, don’t hide them: enhance interpretation, reduce biases and improve reproducibility. bioRxiv 2022.10.26.513929. doi: 10.1101/2022.10.26.513929. [DOI] [PMC free article] [PubMed] [Google Scholar]
- The phys2bids developers, Alcalá D., Ayyagari A., Bright M., Ferrer V., Gaudes CC., Hayashi S., Markello R., Moia S., Stickland R., Uruñuela E., Zvolanek K., 2019. physiopy/phys2bids: BIDS formatting of physiological recordings. doi: 10.5281/ZENODO.3586045. [DOI] [Google Scholar]
- Thomas BP, Liu P, Park DC, van Osch MJP, Lu H, 2014. Cerebrovascular reactivity in the brain white matter: magnitude, temporal characteristics, and age effects. J. Cereb. Blood Flow Metab. 34, 242–247. doi: 10.1038/jcbfm.2013.194. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Thomason ME, Burrows BE, Gabrieli JDE, Glover GH, 2005. Breath holding reveals differences in fMRI BOLD signal in children and adults. Neuroimage 25, 824–837. doi: 10.1016/j.neuroimage.2004.12.026. [DOI] [PubMed] [Google Scholar]
- Thomason ME, Foland LC, Glover GH, 2007. Calibration of BOLD fMRI using breath holding reduces group variance during a cognitive task. Hum. Brain Mapp. 28, 59–68. doi: 10.1002/HBM.20241. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Thrippleton MJ, Shi Y, Blair G, Hamilton I, Waiter G, Schwarzbauer C, Pernet C, Andrews PJD, Marshall I, Doubal F, Wardlaw JM, 2018. Cerebrovascular reactivity measurement in cerebral small vessel disease: rationale and reproducibility of a protocol for MRI acquisition and image processing. Int. J. Stroke 13, 195–206. doi: 10.1177/1747493017730740. [DOI] [PubMed] [Google Scholar]
- Tong Y, Bergethon PR, Frederick B, de B, 2011. An improved method for mapping cerebrovascular reserve using concurrent fMRI and near-infrared spectroscopy with Regressor Interpolation at Progressive Time Delays (RIPTiDe). Neuroimage 56, 2047–2057. doi: 10.1016/J.NEUROIMAGE.2011.03.071. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Tong Y, Frederick BdeB., 2014. Tracking cerebral blood flow in BOLD fMRI using recursively generated regressors. Hum. Brain Mapp. 35, 5471. doi: 10.1002/HBM.22564. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Tong Y, Hocke LM, Frederick BB, 2019. Low frequency systemic hemodynamic “noise” in resting state BOLD fMRI: characteristics, causes, implications, mitigation strategies, and applications. Front. Neurosci. 0, 787. doi: 10.3389/FNINS.2019.00787. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Tsvetanov KA, Henson RNA, Tyler LK, Davis SW, Shafto MA, Taylor JR, Williams N, Cam-CAN, Rowe JB, 2015. The effect of ageing on fMRI: correction for the confounding effects of vascular reactivity evaluated by joint fMRI and MEG in 335 adults. Hum. Brain Mapp. 36, 2248–2269. doi: 10.1002/HBM.22768. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Tustison NJ, Cook PA, Klein A, Song G, Das SR, Duda JT, Kandel BM, van Strien N, Stone JR, Gee JC, Avants BB, 2014. Large-scale evaluation of ANTs and FreeSurfer cortical thickness measurements. Neuroimage 99, 166–179. doi: 10.1016/J.NEUROIMAGE.2014.05.044. [DOI] [PubMed] [Google Scholar]
- Urback AL, MacIntosh BJ, Goldstein BI, 2017. Cerebrovascular reactivity measured by functional magnetic resonance imaging during breath-hold challenge: a systematic review. Neurosci. Biobehav. Rev. doi: 10.1016/j.neubiorev.2017.05.003. [DOI] [PubMed] [Google Scholar]
- Václavů L, Meynart BN, Mutsaerts HJMM, Petersen ET, Majoie CBLM, Vanbavel ET, Wood JC, Nederveen AJ, Biemond BJ, 2019. Hemodynamic provocation with acetazolamide shows impaired cerebrovascular reserve in adults with sickle cell disease. Haematologica 104, 690–699. doi: 10.3324/haematol.2018.206094. [DOI] [PMC free article] [PubMed] [Google Scholar]
- van der Zwaag W, Jorge J, Butticaz D, Gruetter R, 2015. Physiological noise in human cerebellar fMRI. Magn. Reson. Mater. Physics, Biol. Med. 28, 485–492. doi: 10.1007/S10334-015-0483-6/FIGURES/3. [DOI] [PubMed] [Google Scholar]
- van Niftrik CHB, Piccirelli M, Bozinov O, Pangalu A, Valavanis A, Regli L, Fierstra J, 2016. Fine tuning breath-hold-based cerebrovascular reactivity analysis models. Brain Behav. 6, 1–13. doi: 10.1002/brb3.426. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Vogt KM, Ibinson JW, Schmalbrock P, Small RH, 2011. Comparison between end-tidal CO2 and respiration volume per time for detecting BOLD signal fluctuations during paced hyperventilation. Magn. Reson. Imaging 29, 1186–1194. doi: 10.1016/J.MRI.2011.07.011. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Weese-Mayer DE, Lieske SP, Boothby CM, Kenny AS, Bennett HL, Silvestri JM, Ramirez J-M, 2006. Autonomic nervous system dysregulation: breathing and heart rate perturbation during wakefulness in young girls with Rett syndrome. Pediatr. Res. 60, 443–449. doi: 10.1203/01.pdr.0000238302.84552.d0. [DOI] [PubMed] [Google Scholar]
- Williams RJ, MacDonald ME, Mazerolle EL, Pike GB, 2021. The relationship between cognition and cerebrovascular reactivity: implications for task-based fMRI. Front. Phys. 9, 157. doi: 10.3389/FPHY.2021.645249/BIBTEX. [DOI] [Google Scholar]
- Wise RG, Ide K, Poulin MJ, Tracey I, 2004. Resting fluctuations in arterial carbon dioxide induce significant low frequency variations in BOLD signal. Neuroimage 21, 1652–1664. doi: 10.1016/j.neuroimage.2003.11.025. [DOI] [PubMed] [Google Scholar]
- Zacà D, Jovicich J, Nadar SR, Voyvodic JT, Pillai JJ, 2014. Cerebrovascular reactivity mapping in patients with low grade gliomas undergoing presurgical sensorimotor mapping with BOLD fMRI. J. Magn. Reson. Imaging 40, 383–390. doi: 10.1002/jmri.24406. [DOI] [PMC free article] [PubMed] [Google Scholar]
Associated Data
This section collects any data citations, data availability statements, or supplementary materials included in this article.
Supplementary Materials
Data Availability Statement
(Included verbatim in Methods Section 2.3) The MRI images and physiological data used in this study are available on OpenNeuro at doi:10.18112/openneuro.ds003192.v1.0.1 (Moia, Uruñuela, Ferrer, & Caballero-Gaudes, 2020). All code for preprocessing of the MRI data has been prepared to be run in a Singularity container, which is publicly available at https://git.bcbl.eu/smoia/euskalibur_container. The pre-processing pipeline is available at https://github.com/smoia/EuskalIBUR_preproc. Publicly available Python scripts, peakdet (Markello & DuPre, 2020) and phys2cvr (Moia, Vigotsky, & Zvolanek, 2022), were used for processing of CO2 recordings and computation of CVR parameter maps. The open-source Rapidtide v2.2.7 toolbox (B. deB Frederick, Salo, & Drucker, 2022) was used for exploratory analysis (see Discussion Section 4.3). Additional analysis code and details about how they were implemented for this manuscript are shared in the public GitHub repository: https://github.com/BrightLab-ANVIL/Zvolanek_2022.