Abstract
The purpose of this study was to verify the timing of triggering in relation to the cardiac cycle in shooting. The test subjects were six Finnish rifle and pistol champions as well as three beginners at shooting. The electrical activity of the trigger finger muscle (m. flexor digitorum superficialis; surface electrodes) and the heart cycle were fed into a two-channel x-t recorder. The movements of the gun were recorded using a laser technique and, at the same time, cardiac cycles were also monitored. Results showed that the champion shooters triggered during diastole whereas the beginners triggered both during diastole and systole. The results of those beginners triggering during diastole were better than those triggering during systole.
Full text
PDFSelected References
These references are in PubMed. This may not be the complete list of references from this article.
- Jones G. E., Jones K. R., Cunningham R. A., Caldwell J. A. Cardiac awareness in infarct patients and normals. Psychophysiology. 1985 Jul;22(4):480–487. doi: 10.1111/j.1469-8986.1985.tb01635.x. [DOI] [PubMed] [Google Scholar]
- Montgomery W. A., Jones G. E., Hollandsworth J. G., Jr The effects of physical fitness and exercise on cardiac awareness. Biol Psychol. 1984 Feb;18(1):11–22. doi: 10.1016/0301-0511(84)90022-x. [DOI] [PubMed] [Google Scholar]
- Remes A., Rauhala E., Hänninen O. Fully rectified, integrated, band (FRIB-) EMG analysis in quantifying muscle activity. Development of a new field equipment. Acta Physiol Scand Suppl. 1984;537:65–70. [PubMed] [Google Scholar]