Fluorescence Techniques to Study Lipid Dynamics

Erdinc Sezgin 1, Petra Schwille 1
PMCID: PMC3220360  PMID: 21669985

Abstract

Biological research has always tremendously benefited from the development of key methodology. In fact, it was the advent of microscopy that shaped our understanding of cells as the fundamental units of life. Microscopic techniques are still central to the elucidation of biological units and processes, but equally important are methods that allow access to the dimension of time, to investigate the dynamics of molecular functions and interactions. Here, fluorescence spectroscopy with its sensitivity to access the single-molecule level, and its large temporal resolution, has been opening up fully new perspectives for cell biology. Here we summarize the key fluorescent techniques used to study cellular dynamics, with the focus on lipid and membrane systems.


The temporal dynamics of cellular lipids and membranes can be captured using multiple fluorescence-based microscopy techniques. In conjunction with model membrane systems to study lipid dynamics, these techniques have propelled recent research in lipid cell biology.


To elucidate cellular processes in their native dynamic environment has been one of the main issues in cell biology over the past decades. The lack of appropriate techniques has long been the main limiting step for the research on dynamic systems, because it was impossible to acquire real time information with the well-known biochemical techniques. The key challenge in dynamically observing biological systems is to combine the ability to resolve moderate to very low concentrations of molecules—because they are simply limited in living cells—on relevant timescales. Relevant timescales in cell biology can be minutes and hours, on a systemic level of cell metabolism, down to the microsecond and even nanosecond regime in which molecular and intramolecular rearrangements take place. With respect to lipidic systems, relevant dynamics range from the local movements of lipids by diffusion to the mechanical transformations of whole membranes, spanning several orders of magnitude in time to be covered. Like for other cellular processes, the investigation of lipids and membranes also in general benefited greatly from the introduction of fluorescence microscopy and spectroscopy to biology. After the 1960s, great technological inventions based on the phenomenon of fluorescence were made, such as confocal microscopy, fluorescence recovery after photobleaching (FRAP), fluorescence correlation spectroscopy (FCS), Förster resonance energy transfer (FRET), total internal reflection fluorescence (TIRF), and two-photon microscopy, that not only revolutionized imaging but also yielded access to dynamics on previously inaccessible timescales. Another very big step was certainly taken after the introduction of fluorescent proteins, which again accelerated the use of these techniques in living cells and organisms. Nowadays, the technical advancements of fluorescence-based methods allow us to explore systems as small as single molecules with temporal resolution down to the nanoseconds regime. Lately, even the resolution limit of optical microscopy, for a long time being one of the fundamental barriers in elucidating cellular processes, has been overcome by smart applications of the phenomenon of fluorescence.

This article aims at giving a short overview on mainly fluorescence-based methods that have in recent years propelled lipid and membrane research to fully new levels. We will give a short introduction to the modern fluorescence technology in general, referring to the techniques that allow addressing dynamics. A particular focus will be on fluorescence correlation spectroscopy, a technique that our lab works primarily on, but other important methods will also be discussed, including their promises, achievements, and caveats.

FLUORESCENCE TO STUDY LIPID DYNAMICS

The attempt to visualize the “living units” has progressed remarkably after Hooke’s Micrographia. Starting from a simple light source, a mechanical stage, and up to three glass lenses, microscopy nowadays culminated in so-called super-resolution techniques with particle localization accuracies down to the nanometer range. Certainly, the involvement of the phenomenon of fluorescence is one of the biggest steps in this long journey.

Fluorescence is such a ubiquitous phenomenon that it is impossible to speculate about its first systematic observation. The first reported documentation of fluorescence is thought to be Nicolas Monardes’ observation of wood extract. In 1845, John Herschel observed the fluorescent property of quinine sulphate which is believed to be the onset of modern fluorescence spectroscopy. After many more observations by several light philosophers in the 19th century, it was Stokes who actually termed this phenomenon “fluorescence” in 1838. The first application in biology was probably in 1914 Stanislav von Provazek who used fluorescence as a cell stain. August Koehler and Oskar Heimstadt were reportedly the first scientists who performed fluorescence microscopy in early 1900s. Today, a century later, fluorescence imaging and microscopy is one of the most powerful tools in the visualization and dynamic analysis of living structures, especially following the discovery of fluorescent proteins as cloneable markers, and the invention and widespread use of confocal microscopy. Minsky, its inventor, patented the idea of confocal microscopy already in the 1950s, and about 20 years later, the first commercial confocal microscopes appeared. Since then, many researchers and optical engineers step by step improved the technical realization (Brakenhoff et al. 1979; Davidovi and Egger 1973; Egger and Petran 1967; Hamilton and Wilson 1986; Sheppard and Wilson 1979). The rapid developments in laser and detector technology, along with the onset of fiber optics certainly helped in the rapid dissemination of confocal microscopy into cell biology laboratories around the world (Amos and White 2003).

When light interacts with matter, many photophysical phenomena may occur. Some molecules absorb light at a particular wavelength, whereas others predominantly scatter the light. On absorption, the molecules undergo vibrational relaxation on timescales between 10−14 and 10−12 sec, and then return to ground state, either by emitting a photon at a longer wavelength after 10−9 to 10−7 nsec, which is called fluorescence, or nonradiatively. Less probably, the molecules can jump to the quantum-mechanically forbidden triplet state or molecules transfer their energy to other molecules, by quenching or resonant energy transfer. After the molecules undergo the triplet state, they return to the ground state either by emitting light in longer time ranges than fluorescence or nonradiatively.

In the following sections, we will briefly touch on the task of fluorescently labeling lipids to be investigated, and then discuss, one by one, the most powerful biophysical techniques to study lipids and membranes in real time, along with some of their relevant applications.

Fluorescent Probes to Study Lipid Dynamics

After the invention of green fluorescent protein (GFP) as the first truly genetic fluorescent probe, visualizing proteins in their native environment became much more straightforward. From the perspective of the membrane researcher, this significantly improved our understanding of membrane proteins and their dynamics, but could help only marginally in better elucidating the functional dynamics of lipids. The first report on labeling lipids in living cells used azide-alkyne to label alkyne containing PA (Schultz et al. 2010). Besides this direct labeling, coupling the synthetic fluorescence molecules to lipids in vitro, and then reconstitute them to the cell membrane is getting more common in lipid field, enforcing the use of fluorescence also in lipid biology. Synthetic dye coupling has many advantages compared to fluorescent proteins, which nowadays represent the main strategy in protein labeling. First of all, one has theoretically a large choice of organic dyes in terms of their optical characteristics. It is possible, for instance, to use a far red dye; however, there is not yet a well-established monomeric far red protein. Second, the quantum efficiency and brightness of most of the organic dyes are higher than for fluorescent proteins. Cholesterol (Boldyrev et al. 2007; Holtta-Vuori et al. 2008; Marks et al. 2008; Oreopoulos and Yip 2009), Sphingomyelin (Marks et al. 2008; Eggeling et al. 2009; Tyteca et al. 2010), GM1 (Coban et al. 2007; Eggeling et al. 2009; Mikhalyov et al. 2009), PC, and PE (Baumgart et al. 2007; Juhasz et al. 2010) are some of the lipids that are often conjugated to organic dyes. Additionally, fluorescently labeled membrane-binders, like choleratoxin, are used to label, for example, the GMs on the cell surface (Middlebrook and Dorland 1984). However, taking into account that organic fluorophores are in comparison much larger handicaps to small lipid molecules than they are to proteins, and that the relatively tight packing of lipids in a membrane might be more easily disturbed by labeled lipids than in the case of soluble proteins, a careful control of the possible influence of labels on the functionality of lipids is of utmost importance.

Besides fluorescent lipid conjugates, there are some lipophilic fluorescent molecules frequently used to yield information on a specific lipid environment. They efficiently and selectively penetrate into lipid membranes, and to some extent even reflect on their physical properties, like viscosity, order, pH, or water content. DiO, DiD, DiI, Laurdan, and NAP are the lipophilic dyes most commonly used to visualize the lipid environment (Baumgart et al. 2007). Although the Di family of dyes is phase-preferring probes preferring either liquid-ordered (Lo) phase or liquid-disordered (Ld) phase in a specific setting, Laurdan has a different property. It partitions equally in both phases, but its emission spectrum changes according to the polarity of the membrane environment. Providing that Ld phase is more aqueous than Lo phase, on excitation the dye consumes some of its energy to reorient the water molecules in Ld phase, which shifts the emission to the red spectral region (emission maximum of 490 nm), whereas it is more blue shifted in Lo region (emission maximum of 440 nm). According to the ratio of fluorescence intensity in the blue-shifted (Lo phase) and the red-shifted region (Ld phase), one can calculate an order indicative value called generalized polarization (GP) calculated as

GP=I440I490I440+I490, 1

where Ix denotes the intensity at wavelength of x.

In addition to generalized polarization, fluorescence anisotropy is another important phenomenon that can be exploited to monitor rotational diffusion of the molecules by using the polarization of light. Because rotational diffusion is very sensitive to the size of molecules, binding constants can be efficiently derived from fluorescence anisotropy measurements. There have been comparative studies on the feasibility of several dyes for fluorescence anisotropy. Alexa and Oregon dyes conjugates with biological molecules (e.g., lipids), for instance, were found to be suitable for this method (Rusinova et al. 2002). Additionally, NBD and DHP lipid conjugates were used for fluorescence anisotropy to detect rafts in living cells (Gidwani et al. 2001). Laurdan generalized polarization and fluorescence anisotropy were compared elsewhere (Engelke et al. 2001).

Besides lipid probes for the plasma membrane, there are also some tools to probe other lipidic environments in the cell, such as lipid droplets (Thiele and Spandl 2008). New fluorescent lipids were developed to visualize the intracellular and membrane lipids in their native environment without any external fluorescent labels (Kuerschner et al. 2005; Spandl et al. 2009).

Confocal Microscopy

Confocal microscopy may easily be the most widely applied imaging technique in cell and molecular biology field because it allows live cell imaging with high spatial and temporal resolution, as well as optical sectioning and 3D reconstruction of images. To start with the techniques for cell dynamics, confocal microscopy should therefore be briefly mentioned because it forms the basis (and often the gold standard) for most of the other techniques.

The confocal concept evolved as an alternative to wide-field microscopy. For wide-field microscopy, the so-called Koehler illumination guarantees a homogeneous illumination of the whole sample, which is then detected by area detectors. In contrast to this, confocal illumination occurs only at a resolution-limited point, which can then be sequentially scanned in three dimensions throughout the sample. As a technical difference, coherent light sources (lasers) are usually employed in confocal microscopy, whereas incoherent lamps are still mostly used in wide-field microscopy. However, the basic difference between wide-field and confocal microscopies is a so-called pinhole aperture which eliminates the out-of-focus light in the image plane, being the main source of background in wide field. The minimal size of the confocal illumination volume, and therefore the resolution that can be reached in confocal microscopy is usually determined by the so-called Rayleigh criterion. Here, resolution of the wide field is defined as the shortest distance d between two optically separable points:

d=0.61×λNA, 2

where λ is the wavelength and NA is the numerical aperture of the objective. When the advantage of selective detection (pinhole) and selective illumination (diffraction limited spot by coherent light source) are applied, the resolution reaches a better point:

d=0.4×λNA, 3

Taking above equation into consideration, the theoretical resolution of a confocal system with an NA of 1.4, at a wavelength of 500 nm should be ∼160 nm. However, all theoretical calculations consider a perfect optical system and a pinhole of a laser spot size (i.e., Airy disc size). Yet, there are many aberrations caused by imperfect optics such as spherical aberrations, chromatic aberrations, astigmatism, comma etc. Moreover, pinhole size can never be as small as laser spot size. The biggest problem in confocal microscopy is, however, the large discrepancy between lateral (x–y) and axial resolution, resulting in image stacks that are usually quite blurred in the z dimension.

Axial resolution is given by

dz=1.4×λ×nNA2, 4

where n is the refractive index of the medium. The axial resolution is usually three to five times worse than lateral resolution.

The limitation in axial resolution is a minor problem for pure membrane systems with little to no contribution of fluorescence light coming from the solution above and below the membrane. Thus, confocal microscopy has been particularly useful on supported membranes or giant unilamellar vesicles (GUVs) (Korlach et al. 1999). On the other hand, for the study of cellular membranes with their rather high background from cellular autofluorescence and labeled molecules that cannot easily be retained at the cell surface (e.g., because of endocytosis), limited z resolution can be a significant technical problem in studying lipid dynamics. For this reason, other illumination strategies established for fluorescence microscopy, such as total internal reflection (TIR), are becoming increasingly popular for lipid and membrane research.

Total Internal Reflection Fluorescence (TIRF) Microscopy

Total internal reflection is a well-known phenomenon in everyday life. When a light beam passes from a medium with a refractive index n1 to the other medium with a refractive index n2, the relationship between the angle of incidence α1 and the angle of refraction α2 is determined by Snell’s law:

n1sinα1=n2sinα2. 5

When n1 > n2 (e.g., when light is propagating from water or glass into air), there exists a critical α1 angle that would render the refraction angle to be 90° (i.e., parallel to the interface). At incidence angles equal to or greater than this critical angle, light cannot cross the boundary, and is internally reflected. This phenomenon is called total internal reflection (TIR). The critical angle (αc) is determined by the refractive indices of the media:

αc=sin1(n2/n1). 6

Although the light ray is totally reflected, its electrical field creates an evanescent wave whose intensity decreases exponentially in the axial direction (Fig. 1):

I(z)=I(0)ez/d, 7

where d is defined as

d=(λ4π)(n12sin2α1n22)1/2, 8

and λ is the wavelength. The principle is schematically depicted in Figure 1.

Figure 1.

Figure 1.

Evanescent wave and TIRF.

The most remarkable feature of TIR illumination for membrane research is that the evanescent wave illuminates only a limited distance (∼100 nm) along the z-axis, which reduces background coming from molecules above the surface substantially, thereby increasing the axial resolution and the signal-to-noise levels. The detailed physics behind TIR can be accessed from references Axelrod (2008) and Axelrod et al. (1983).

There are currently two methods to realize this illumination mode for fluorescence microscopy. The first, simpler, method is to use a high-NA TIRF objective. The light beam entering the objective is focused at the back focal plane of the objective with a displacement from the optical axis, such that it reaches the surface above the critical angle. Surface fluorescence is collected by the same objective and can be detected in the usual way.

The necessity for using a high-NA objective can be understood by considering that

NA=nsinθ. 9

Then, Equation 8 can be rewritten as

d=(λ/4π)(NA2n22)1/2. 10

When NA < n2, d is imaginary, which means light is refracted and TIR is lost. That is why the NA of TIRF objectives should be higher than the refractive index of the sample medium. A living cell has a refractive index of 1.33–1.38. Many current TIRF objectives thus have a NA of 1.45, which creates a penetration depth of the evanescent field of 82 nm at 488 nm excitation just above the critical angle.

The second way to create an evanescent wave is to use a prism. In this case, the sample is located between the prism and objective. The illumination is performed through the prism, while the objective collects the emission and transfers the signal to the camera. This decoupling of illumination and detection can be quite useful to create large illumination areas, but is less comfortable than objective-based TIR, which can be easily realized in any fluorescence microscope.

Further advantages of prism-based TIR are lower background and a better control on angle and polarization. It is also easy to set up for two colors. On the other hand, the free access to one side of the sample, safety of lasers, ease to use with cell culture plates can be counted as the advantages of objective-based system.

TIRF can be coupled to other techniques as a specific illumination mode when good z resolution is crucial. It has been combined with FCS, FRET, FRAP, AFM, fluorescent lifetime imaging, two-photon excitation, optical traps, and interference reflection. Some combinations of these techniques will be discussed later.

Polarized TIRF

The fluorophores can be excited only if their dipole is parallel to the excitation light dipole, which is called photoselection. A variation of TIRF called polarized TIRF uses polarized light perpendicular to the incidence plane (p-polarized) and parallel to the incidence plane (s-polarized) to overcome this limit. If the dipole of a fluorophore is always parallel to the membrane surface, p-polarized light can help to excite only the regions where the membrane is not parallel to the surface. The investigation of membrane curvature can be an important application field for polarized TIRF (Axelrod 2008).

TIRF Applications on Membrane Dynamics

There have been many studies to elucidate membrane dynamics using TIRF. Recently, it has been shown that TIRF has the capacity to show the adsorption of proteins and peptides to lipids in SLBs (Fox et al. 2009; Jorgensen et al. 2009). TIRF was combined with single-particle tracking to show the enrichment of GPI-anchored proteins in sphingolipid rich regions, as proposed by lipid raft theory (Pinaud et al. 2009). A new method has also been applied to detect lipid rafts, called LG-TIRF (Sohn et al. 2010). Other applications were to elucidate the role of ceramide in membrane restructuring (Ira et al. 2009), the organization of bacterial light harvesting complex 2 (Dewa et al. 2006), the role of cholesterol in antibody binding (Yu et al. 2009), EGFR activation by EGF (Sako et al. 2000; Cannon et al. 2005; Teramura et al. 2006), and the phase preference of peptides (Choucair et al. 2007). Membrane curvature, exocytosis, and endocytosis are some other topics in which TIRF is successfully applied (Merrifield et al. 2002, 2005; Byrne et al. 2008; Nagamatsu and Ohara-Imaizumi 2008; Joselevitch and Zenisek 2009; Ohara-Imaizume et al. 2009; Aoki et al. 2010; Gorg et al. 2010; Lam et al. 2010).

Two-Photon Microscopy

The theoretical basis of two-photon excitation was laid in a study of the early 1930s (Goppert 1929), although the experimental realization took almost three decades (Kaiser and Garrett 1961). It was first used in LSM in the 1970s (Hellwarth and Christensen 1975) but a convincing two-photon excitation fluorescence microscopy was only demonstrated in 1990 (Denk et al. 1990).

Two-photon microscopy, as the name implies, uses simultaneous absorption of two longer wavelength photons (at λ1 and λ2) to excite a fluorophore, which would be usually excited by a single photon at a shorter wavelength (λ3). The relationship between the wavelengths is

λ3=1λ11+λ21. 11

Because the two photons have to be absorbed simultaneously to excite the fluorophore, the excitation is dependent on the square of the light intensity. This could be thought as an equivalent of the double selection in confocal imaging, achieved by a selective illumination by the light source and selective detection by a pinhole. Therefore, in the two-photon illumination mode, a pinhole is no longer necessary. Moreover, it minimizes the out-of-focus photobleaching because the excitation only occurs in the vicinity of the focal plane (Fig. 2). Scattering is greatly reduced with two-photon excitation, and penetration depths for the long wavelength excitation are increased.

Figure 2.

Figure 2.

(A) Two-photon illumination and (B) single-photon illumination.

Because the emission does not have to pass through a pinhole, area detectors can be used and no descanning of the beam is necessary, making detection quite simple.

Another advantage of two-photon microscopy is its ability to excite fluorophores absorbing in the UV by two photons in visible range, which surpasses usual UV transmission problems with glass lenses. In combination with the reduced out-of-focus fluorescence, it also provides a suitable tool for UV uncaging in vivo without significant photo damage.

The photon density in two-photon excitation should be about one million times higher than is required for single-photon excitation, because of the square dependence of the absorption on intensity. Therefore, pulsed lasers should be used with sufficient photon flux in the pulses while having fairly low average power. Titanium-sapphire lasers are extensively used for two-photon microscopes because they provide a wide range of excitation wavelengths between 700 and 1100 nm. Because of different photophysical selection rules, two-photon absorption spectra are not identical with twice the spectra for one-photon excitation, and have therefore to be independently determined. In the same way as for TIR illumination, two-photon excitation can be combined with other single-molecule techniques.

Applications

Two-photon microscopy is very suitable to excite photosensitive, easily bleachable lipid probes in the blue to near-UV spectral range, such as Laurdan or C-Laurdan. These probes were used to detect the membrane domains in model membranes, as well as in living cells, by two-photon microscopy (Parasassi et al. 1997; Bagatolli and Gratton 1999, 2000a,b; Dietrich et al. 2001; Bagatolli 2003; Bagatolli et al. 2003; Kim et al. 2007; Kaiser et al. 2009). The order of different membrane systems was investigated (Gasecka et al. 2009), and new probes to visualize the membrane order were tested by two-photon microscopy (Jin et al. 2006; Kim et al. 2008; Klymchenko et al. 2009).

Fluorescence Recovery after Photobleaching (FRAP)

FRAP or, under its previous name, fluorescence photobleaching recovery (FPR) was first described in the late 1970s (Axelrod et al. 1976; Koppel et al. 1976) and got very popular in the 1990s because of the improvements in optics and the discovery of fluorescent proteins.

FRAP is a technique that exploits the photobleaching property of fluorophores. A region of interest (ROI) is bleached with a high laser power. Then, the ROI is observed for fluorescence recovery, caused by diffusion, interactions or reactions of the surrounding fluorophores, which yields a recovery curve. This curve typically looks like the one shown in Figure 3. Its most remarkable features are the bleaching step, an exponential-like recovery with characteristic half-time, and a recovery level usually lower than the initial level, whose offset is the so-called “immobile fraction.”

Figure 3.

Figure 3.

FRAP parameters. 0 < t is the time before the bleaching, t0 is the time at which bleaching occurs, t1/2 is the half-life (i.e., the time at A/2), A is the mobile fraction, and 1 – A is the immobile fraction.

According to the steepness of the recovery, diffusion coefficients, binding rates or turnover rates can be determined. The steeper the recovery is, the faster the molecules are, with diffusion coefficients (D) determined by the Stokes–Einstein relationship for spherical molecules:

D=kBT6πηr, 12

where kB is the Boltzman constant, T is the absolute temperature, η is the viscosity, and r is the hydrodynamic radius of the spherical particles.

Because photobleaching is an irreversible process, immobile molecules will not recover at all. Therefore, one can obtain the immobile fraction of molecules as an additional information from FRAP curves. To get accurate quantitative information, the intensity profiles of bleached ROI, as well as an unbleached positive reference ROI on the same membrane, an empty ROI outside of the membrane, and the whole cell or membrane have to be derived. Then, the recovery should be normalized according to these values (Kenworthy 2007).

Normalized FRAP curves should be fitted to the appropriate models, to get the half time which is the time required for half of the recovery. The simplest fitting is by a single exponential:

f(t)=A(1eτt). 13

The diffusion coefficient can then be determined as

D=r02γ4τ1/2, 14

where r0 is 1/e2 radius of the Gaussian laser beam, γ is the parameter that depends on the photobleaching extend varying from 1.0 to 1.2 depending on ROI shape, and τ1/2 is the half-time. In case of a uniform circular spot ROI,

D=0.224r2/td. 15

Many fitting models for diffusion, interaction and reaction have been developed recently, some of which are listed in Table 1.

Table 1.

FRAP fitting models

graphic file with name cshperspect-LIP-a009803_T1.jpg

TIR-FRAP

To measure the diffusion of molecules in a membrane, TIR illumination can be a better option than confocal microscopy for the same reasons as listed above. With TIR-FCS, complex binding-unbinding measurements are possible with high accuracy because of well-defined and background free illumination.

Challenges and Artifacts in FRAP

FRAP is usually implemented in laser scanning confocal microscopes (LSCMs), thus its ability is limited by the features of the respective microscope. In FRAP experiments, it is usually assumed that all the molecules are bleached at the same time, and no diffusion happens during photobleaching. But both assumptions may be wrong at nonideal settings in an LSCM. To guarantee proper photobleaching, more than one scan at high laser power may be needed. However, as the number of scanning cycles increases, diffusion into the ROI is nonnegligible, especially for fast diffusing molecules. This leads to a wrong initial starting point of recovery, and yields a wider and shallower bleaching profile. In other words, the required time for molecules to recover the bleached area appears to be higher. To get rid of this artifact, the initial point needs to be calibrated carefully (Snapp et al. 2003; Weiss 2004).

ROI Size

The shape and the area of the FRAP ROI are crucial for the extraction of diffusion coefficients. The ROI size should be much smaller than the total size of the sample, to keep the overall fraction of photobleached molecules fairly low, not to influence the fluorescence intensity profile of the sample. Moreover, ROI radius should not exceed 1 µm for Gaussian approximation to be valid.

Photobleaching Artifacts

During photobleaching, many chemical reactions can happen because of the high laser power, induced by radical (often reactive oxygen) formation, such as protein cross linking. This may affect the concentrations but also the diffusion coefficient notably. Another effect of high laser power, particularly in the red spectral range, can be a slight local temperature rise during photobleaching. Although it has been shown that the temperature increase is minor (Axelrod 1977) in solution, it may be important on membranes, specifically at critical temperature points (Honekamp-Smith et al. 2008).

Besides experimental parameters mentioned above, a proper fitting should be carefully applied (Sprague and McNally 2005).

Applications

The diffusion in native cell membranes has been addressed using the FRAP technique since long (Lippincott-Schwartz et al. 2001, 2003). The first studies were performed to see whether membrane heterogeneity affects the diffusion of proteins in the membrane (Edidin 1992; Jacobson et al. 1995; Feder et al. 1996; Lommerse et al. 2004; Kenworthy 2005; Lagerholm et al. 2005), which resulted in anomalous diffusion concept. In the context of lipid rafts, a continuous effort has been made to distinguish between the diffusion of raft and nonraft markers, as well as to characterize the factors that can influence the membrane organization, like cholesterol (Niv et al. 1999, 2002; Hao et al. 2001; Kenworthy et al. 2004; Rotblat et al. 2004; Goodwin et al. 2005; Roy et al. 2005; Meder et al. 2006; Nicolau et al. 2006; Shvartsman et al. 2006). TIR-FRAP was applied to calculate the rates of binding and unbinding of hormones to and from the cell surface (Hellen and Axelrod 1991; Fulbright and Axelrod 1993).

Fluorescence Correlation Spectroscopy (FCS)

FCS is a method that has been extensively used and further developed by our group, being introduced and established as a very suitable approach to characterize model and cellular membranes (Schwille et al. 1999a; Bacia et al. 2004). It is, in a way, a single-molecule method, but provides sufficient statistical significance to also use it for general characterization of membranes, mainly through the diffusion properties of their constituents. It is thus related to FRAP, but provides several advantages, the most crucial of which is the dramatically improved sensitivity, allowing to work at significantly reduced fluorescence labeling densities. FCS has long been used to characterize domain-forming membranes (Korlach et al. 1999), and recently, by combination with super resolution illumination (Eggeling et al. 2009), was able to resolve nanometer-sized entrapment sites of labeled raft-markers. Because of our intensive efforts on FCS applied to membranes, this technique will be discussed in more detail in the following.

FCS measures small fluorescence intensity fluctuations in a defined volume. It provides accurate information about diffusion coefficients, concentrations, molecular brightness, intramolecular dynamics, and molecular interactions. It has been extensively used for a variety of biological applications, because of its great sensitivity. FCS has been combined with many different imaging methods, such as laser scanning confocal microscopy, two-photon microscopy, total internal reflection fluorescence microscopy, stimulated emission depletion nanoscopy, and others, making it particularly feasible for cell biology.

FCS was first established in the 1970s (Magde et al. 1972, 1974, 1978; Elson and Magde 1974) and technically greatly improved in the following years (Rigler et al. 1993; Eigen and Rigler 1994). Fluorescence intensity fluctuations, primarily addressed by FCS, can be caused by diffusion of the molecules through the observation volume, or by reversible brightness changes of the molecules because of some chemical or photophysical reactions (Petrov and Schwille 2007). FCS performs the statistical analysis of these fluctuations. In other words, it correlates a signal at a certain time t with the same signal after a lag time t + τ, and takes the temporal average. This correlation can be described as self-similarity of the signal in time, which is represented by the autocorrelation function, a temporal decay function of average fluctuations. The basic formula for the fluctuation autocorrelation function is

G(τ)=δF(t)·δF(t+τ)F(t)2, 16

where δF(t) = F(t) − 〈F(t)〉 is the fluctuation around the average intensity and 〈 〉 denotes the temporal average; τ is the lag time. The denominator is for normalization.

The basic steps of FCS experiments are as follows. First, the sample is illuminated by the appropriate illumination technique. Generally, in the simplest representation of FCS, confocal illumination without beam-scanning is used. The fluorescence signal is collected by the objective and detected by sensitive photodetectors, often by avalanche photodiodes (APDs). After detecting the fluorescence intensity for a certain time, a hardware correlator usually correlates the signal from subsequent time points according to the correlation function mentioned above, and forms the experimental FCS curve. This correlation step can also be performed retrospectively, if data is recorded in small enough (<µsec) time bins. Then, the correlation curve as in Equation 16 is fitted by an appropriate fitting model (some listed below) to get the numerical values of diffusion times, concentrations and molecular brightness, or other parameters governing fluctuation decay.

As seen in Figure 4, the amplitude of the curve is reciprocal to the concentration. The reason behind this is that for lag time zero, G(τ) is determined as

G(0)=(δF)2F2. 17

Figure 4.

Figure 4.

Principle of FCS. (Image courtesy of Jonas Ries.)

For random processes that are governed by Poisson statistics, the variance is

Var(N)=(δN)2=N. 18

Because the fluorescence intensity is directly proportional to the number of molecules,

F=qN, 19

when the intensity is normalized, we get

(δF)2F2=(δN)2N2=NN2=1N. 20

As stated above, the diffusion time and other variables are obtained from fitting the experimental data to the proper model function. From the diffusion time τD, the diffusion coefficient can be determined if the diameter of the focal volume is known:

τD=ωo24D. 21

Here, ωo is the beam waist of focal volume (i.e., the radial distance of the optical axis), and D is the diffusion coefficient.

Besides the concentration and the diffusion time, the brightness of the molecule, η, can be calculated. This parameter is quite important for a good statistical accuracy, and can be used to assess the quality of FCS measurements in general. However, it can also reflect on the formation of higher molecular complexes and aggregates. η is directly proportional to the total photon count and to the amplitude of the correlation function:

η=F(t)N=F(t)·G(0). 22

In practice, FCS is quite a complicated and delicate technique to apply, with many parameters that have to be taken into account and carefully controlled.

  • If the concentration of the fluorophores is too high (>100 nm) the contribution of correlated photons to the total intensity (or, the strength of the fluctuations) is only marginal, and precludes their analysis. If the concentration is too low (<1 pm) it gets difficult to register a molecule in the focal volume during a sensible measurement time. Background noise dominates the signal. In both cases, it is difficult to record decent FCS curves.

  • Autofluorescence and (scattering) background may always affect the total fluorescence intensity, and there should be elaborate corrections for them. Besides, the sample should be kept in a nonautofluorescent medium.

  • Low laser power should always be used to avoid photobleaching.

  • The acquisition time should be long enough to collect enough photons to correlate, but not too long to avoid photobleaching.

  • Fluorophore selection should be made carefully; more than other techniques FCS requires a high photostability.

The basic steps and tricks to do FCS on living cells are well described (Kim et al. 2007).

More problems, precautions, and corrections will be discussed later.

Fluorescence Cross-Correlation Spectroscopy (FCCS)

To quantitatively characterize molecular interactions is of prime importance for cell and molecular biologists. Biochemical assays that are usually employed for this purpose are particularly problematic for molecules embedded in or attached to cell membranes, because the physiological environment cannot be closely preserved in vitro. Video microscopy on fluorescently labeled molecules in life cells has helped to some extent, but often produces ambiguous results, because it largely relies on simple colocalization that does not really probe interaction, but rather spatial proximity. As the diffraction limit is much larger than a protein size, when two proteins are closer than the resolution of the microscope, it cannot be determined whether they are truly interacting. A much better approach is FRET, relying on the radiation-less transfer of excited state energy between two or more molecules that carry fluorescent labels with large spectral overlap. Here, the proximity needs to be in nanometer range, making it much more specific to probe true binding. FRET will be discussed in detail later. However, the key challenge with FRET is to attach the labels close enough to the binding site to yield high transfer efficiency, but far enough apart not to interfere with the binding. Here, a variant of FCS, called fluorescence cross-correlation spectroscopy (FCCS) often provides a valuable alternative.

FCS itself provides detailed information on the diffusion properties of labeled molecules. To probe binding or interaction of small molecules to large ones, or to immobile structures such as the cell membrane, the reduction in diffusional mobility may provide valuable information on the binding process. This has in the past been used to characterize binding events by standard one-color FCS (Icenogle and Elson 1983a,b). However, this approach breaks down when the interaction between molecules of approximately the same size are to be analyzed. Simulations show that for the minimum detectable difference in diffusion time of a molecule of at least 1.6-fold, an approximately sixfold change in mass is required, as implicitly seen in Equation 12, where the diffusion time is inversely proportional to the third root of mass (Meseth et al. 1999).

The principle of FCCS is to observe codiffusion of molecules, rather than colocalization. It can thus be employed to probe any phenomenon leading to or terminating such a comovement (Schwille et al. 1997). Direct interaction, complex formation, but also the clustering of molecules in microdomains or nanodomains can lead to such a codiffusion of two molecules of separate species. In contrast to standard FCS, the mathematical routine for FCCS is to correlate the fluorescence fluctuations from the first channel at time t with the fluorescence fluctuations in the second channel at time t + τ over a certain measurement interval (Fig. 5). The cross-correlation function Gcc(τ) for FCCS is given by

Gcc(τ)=δF1(t)·δF2(t+τ)F1(t)F2(t), 23

where δF1(t) and δF2(t) are the fluctuations in the two fluorescence signals, and 〈F1(t)〉 and 〈F2(t)〉 are the mean intensities.

Figure 5.

Figure 5.

Principle of FCCS. (Image courtesy of Jonas Ries.)

Scanning FCS (sFCS)

Although FCS is still mostly performed with a steady measurement volume (i.e., a confocal spot parked at a fixed position in solution or in a cell), many modern instruments, particularly combined FCS-LSM modules, feature the combination of correlation analysis with a scan beam. Here, the focal volume may be moving on a line (Petersen 1986; Petersen et al. 1986), a circle in lateral axis (Petrasek and Schwille 2008; Petrasek et al. 2010) or along z-axis (Benda et al. 2003). The basic principle of scanning FCS perpendicular to the membrane is shown in Figure 6.

Figure 6.

Figure 6.

Principle of sFCS. (Image courtesy of Jonas Ries.)

In the line-scan mode, the laser focus moves perpendicularly to an axially aligned membrane (e.g., the side membrane of a giant vesicle). Because of the scan path being much larger than the actual intersection with the membrane, the focal spot will only be illuminating (membrane-bound) molecules for a small fraction of time. Thus, the recorded time-intensity trace cannot be directly fed into the hardware correlator but has to be processed by software to align the actual membrane intersections, before actually correlating the processed pseudo-real time signal and fitting the data (Ries and Schwille 2006). This procedure, although more elaborate than standard FCS, has the enormous advantage that sample drift or large-scale signal disturbance by autofluorescent particles can be efficiently suppressed. Although line-scan FCS has many advantages for membrane systems, which are going to be discussed later, it may cause out of focus bleaching, and its time resolution is limited by the software processing, rendering it unattractive to detect fast diffusing components in solution.

Besides a line scan in the lateral direction, there is an axial scanning approach in which the focal volume moves in the z direction, so that it can measure above the membrane, at the membrane and below the membrane sequentially (Humpolickova et al. 2006). Because of the laser divergence, the size of the illuminated area above and below the focal plane are larger, rendering the number of molecules and the diffusion time higher when moving the focal spot away from the focal plane. Also, the movement is usually performed by stage scanning, with much lower scan speed than available for lateral scanning, Consequently, this z scan is usually performed for other purposes: for example, to calibrate the focal volume in the z direction or to vary the size of the illuminated area on the membrane with minimal efforts.

Two-Focus FCS

Another modification of FCS that bears the characteristics of cross-correlation is two-focus FCS (or dual focus FCS). It can be implemented with two fixed confocal volume elements displaced with respect to each other at a spatial distance. This setup simplifies calibration—less measurements of diffusion coefficients (Dertinger et al. 2007). Spatial cross-correlation with two focal elements can, however, be conveniently combined with line scanning, in which two identical lines at a known distance d are scanned by two foci simultaneously, or alternately with very high frequency. When the distance is well known, one can extract autocorrelation curves as well as the spatial cross correlation curve between two foci. This mode is quite insensitive to artifacts that originate from the variations of the focal volume (e.g., because of different refractive indices within the sample [Dertinger et al. 2007; Loman et al. 2008]), and therefore particularly suited for cellular FCS. This will be discussed later.

TIR-FCS

As mentioned before, TIR illumination provides a great axial resolution, which makes it a very appropriate tool for membrane research. It can also be conveniently combined with FCS on membranes or surfaces in general. If there is a strong background from labeled molecules in the cytosol, or above and below the surface of interest, selective data processing in scanning FCS or two-focus FCS can only partly overcome this problem, which usually leads to a decrease in amplitude in the correlation curve. As a much more elegant strategy to eliminate the background caused by any other molecules away from the surface, objective-type TIRF illumination combined with standard confocal detection can be applied (Schwille 2003; Ries et al. 2008).

Two-Photon FCS

To combine FCS with two-photon excitation provides a number of interesting features and advantages. First of all, like for standard imaging, it limits cumulative photobleaching in out-of-focus areas, making it preferable for FCS measurements on samples with limited dye resources such as small cells and organelles (Schwille and Heinze 2001; Schwille et al. 2009). Two-photon excitation is, further, the method of choice for samples of high turbidity or high scattering cross sections, like multicellular systems or cells with thick cell walls. Additional advantages may be provided by the photophysical properties of the dyes, allowing to coexcite and correlate up to three spectrally distinct fluorophores with one two-photon excitation beam (Heinze et al. 2000, 2002). Caution has to be applied with regard to the photostability of dyes and the available count rate per molecule, as both seem to be significantly reduced under two-photon excitation (Schwille et al. 1999b).

Difficulties and Artifacts in FCS Applications

Background

Background can be caused by scattering, autofluorescence, or unwanted fluorophores in the sample because of nonspecific labeling. If the background is truly random and noncorrelated, a signal can be easily background-corrected after the measurement as follows (Petrasek et al. 2010):

gc(τ)=(FFB)2g(τ), 24

where gc(τ) is corrected nonnormalized correlation, g(τ) is measured nonnormalized correlation, B is background fluorescence measured on the sample without fluorescent molecules, and 〈F〉 is the average intensity.

In case of correlating background, it has to be added to the fitting functions as a fixed second component in a two-component model after being carefully calibrated.

Membrane Heterogeneities, Blinking, Triplet, and Photobleaching

FCS usually assumes an equilibrated steady state in the focal volume around which fluctuations occur randomly. This means that the average count rate should not change over time when recording an FCS curve. In reality, this assumption is very rarely true. Many events, above all cumulative photobleaching, cause a continuous drop or other large scale drift in the average count rate, rendering the error-free recording of FCS curves quite complicated.

In measurements on live cell membranes, membrane undulations constitute the main problem. As the membrane may always be moving on a micron scale, the fraction of membrane occupying the detection volume can change drastically. This causes an increase or decrease in count rate, and results in major distortions of the curve, leading to erroneous values for autocorrelation amplitude and diffusion time.

Another cause of severe, although better controllable, distortion of FCS curves is the photophysical phenomenon of triplet state population, in which the molecules are trapped in a dark state for a few microseconds. Triplet-induced photophysical dynamics may lead to wrong fitting of diffusion times, particularly if the triplet fraction is high and the diffusion times are short (Davis and Shen 2006). Yet, this phenomenon can usually be corrected for in the fitting function, as seen in Table 2. Usually, triple dynamics can be easily distinguished from diffusion because it is independent of volume size, but dependent on illumination power. It can be easily evidenced as an additional shoulder in the FCS curve on short timescales.

Table 2.

FCS fitting models

graphic file with name cshperspect-LIP-a009803_T2.jpg

Blinking on short timescales does not have to be of photophysical origin. Several fluorophores, particularly fluorescent proteins such as GFP, exhibit excitation independent dark state-bright state transitions which may, however, be dependent on pH or ionic strength of the solution (Haupts et al. 1998). After careful calibration, this can be incorporated into the fitting function in the same way as the triplet dynamics (Table 2).

A more severe problem for FCS is dye photobleaching, as it not only leads to signal loss, but also compromises the determination of concentrations and diffusion coefficients, the key parameters in FCS applications. At too high illumination intensities, molecules will not stay fluorescent during their full diffusion path through the detection volume, but will be destroyed before leaving it again, leading to erroneously low diffusion times, and an overestimation of diffusion coefficients. In living cells, there is an additional problem with immobile fluorophores being unavoidably bleached during the measurements and leading to a drift in the overall count rate. To prevent this effect from destroying the correlation curve during real-time recordings, a prebleaching is usually performed. Although photobleaching can be usually diagnosed by decay in count rate, its effect is not necessarily visible on first sight, because an equilibrium state may be reached between bleaching and continuous supply of new fluorophores. To rule out photobleaching-induced artifacts in general, a laser power series of FCS measurements from minimum to a moderate power should be recorded. Only for power levels that do not show a change in the curve parameters, compared to very low power measurements, the intensity can be assumed safe (Dittrich and Schwille 2001; Delon et al. 2004). This “safe intensity” is, however, dramatically dependent on the diffusion characteristics of the labeled molecules (lower intensities required for slower molecules), and cannot just be inferred from pure dye measurements.

For measurements on extremely slow particles, scanning FCS as explained above represents an efficient solution to avoid photobleaching-induced artifacts, because the laser is not continuously exciting the same spot, reducing the interaction time with a specific region.

Detector Dead Time and Saturation

When a photon hits the APD detector, it creates an avalanche of electrons to amplify the signal. Before the next photon can be registered, there is a short interval of ∼100 nsec, called the dead time of the detector. Events occurring on shorter scales than the dead time cannot be resolved. Sometimes, the detection of a single photon triggers the APD chip to create a second cascade during the dead time, the so-called “afterpulsing,” which is an artifactual event, but highly correlated with the first one. As a result, a peak in the correlation curve is observed at very short timescales. The simplest solution for this (usually hardware-induced) problem is to split the light into two detection channels and record the cross-correlation between them. Cross-correlation does not include this after-pulsing peak because it is a hardware-induced phenomenon in only one of the detectors.

There is a photon count limit for the detector that it can process at a time. Above this value, electronic saturation occurs, which has a similar effect as optical saturation in the sample. Optical saturation happens when most of the molecules in the focal volume are not in the ground state, instead in excited state or triplet state. This effect usually leads to an enlarged focal volume and results in a slower decay of the correlation function (Gregor et al. 2005; Humpolickova et al. 2009). It should be ruled out in the same way as for photobleaching, by recording a laser power series and staying well below the intensity at which the curves change their shape.

Focal Volume Geometry and Positioning

The probe volume (composed of illumination by the laser and detection via the pinhole) is usually approximated as a 3D Gaussian profile. In one photon excitation, slightly underfilling the back aperture of the objective is a good way to satisfy this approximation. Overfilling the aperture to yield better excitation efficiencies, on the other hand, will for one-photon excitation result in diffraction fringes of the back aperture itself. This non-Gaussian volume is prone to produce artifacts in diffusion time, which may be misunderstood and taken as a second species or kinetics (Hess and Webb 2002).

There are several additional factors, like optical aberrations, that distort the geometry (shape or size) of the focal volume from the Gaussian profile.

Refractive index mismatch could be a common problem when dealing with cells, in which refractive indices vary from 1.33 to 1.38. When there is a mismatch between the immersion liquid, glass, and the sample, aberrations occur which cause a larger detection volume than assumed by the fitting model. This results in larger diffusion times and lower diffusion coefficients than the real values. Similar to this, displacement of the pinhole along the optical axis leads to larger detection volumes and larger diffusion times. Coverslip thickness also affects the focal volume. Objectives are usually designed for a certain range of coverslip thickness that has to be adjusted exactly. Deviations from the correct value again result in a larger detection area and underestimated diffusion coefficients (Enderlein et al. 2004, 2005).

Artifacts caused by refractive index mismatch, pinhole misalignment, or coverslip thickness affect the control experiments in the same way as the measurements, such that the ratio of control over sample is still correct. If absolute values are to be obtained and the optical system cannot be easily corrected, two-focus FCS provides a good solution to avoid problems with detection volume deformations. Two-focus FCS is insensitive to refractive index mismatch, cover-slide thickness variation, and optical saturation. Therefore, it happens to be a focal volume-calibration free technique for accurate dynamics measurements (Dertinger et al. 2007; Loman et al. 2008).

Correct axial positioning of the detection volume is crucial for membrane analysis. If the center of the focal volume is not exactly on the membrane, the divergent laser beam illuminates a bigger area of the membrane, mimicking a higher concentration (through the reduced count rate and higher occupation number) and a smaller diffusion coefficient. To minimize this artifact, the count rate should be maximized when adjusting the z position. For a more decisive solution, positioning-calibration free FCS variants like scanning FCS or z-scan FCS should be used.

Specific Artifacts in FCCS

One of the most crucial tasks for dual-color cross-correlation is the careful determination of measurement volumes. Because of the different wavelengths, the Airy disc sizes for the two detection channels vary in proportion to their wavelength. Consequently, in most FCCS instruments, the focal volumes do usually not completely overlap, even after eliminating all aberrations (Weidemann et al. 2002). For quantitative FCCS, this requires intensive calibration measurements (Schwille et al. 1997) (e.g., by using a “gold standard” of up to 100% cross-correlation [like a strong receptor-ligand or dsDNA] and comparing the experimental results with this reference).

One of the biggest problems in most optical systems featuring multicolor applications is spectral cross talk. FCCS is particularly prone to producing false positive results because of the cross talk induced by the leakage of the green dyes’s emission into the red dyes’ detection channel. In that case, the autocorrelation between the red and green spectral parts of the green dye results in false positive cross correlation.

As for other artifacts, cross talk can be taken care of by careful calibration. The cross talk coefficient of any fluorophore κx can be easily calculated by measuring the fluorescence simultaneously in both channels. This coefficient is specific for a particular set of optics (dichroics, filters, etc.):

κx=Fr/Fg, 25

where Fr is the fluorescence intensity in the red channel, and Fg is the fluorescence intensity of the same fluorophore in the green channel.

Cross-correlation can be corrected according to this coefficient in measurements with two fluorophores:

GCC(τ)=FgFrGrg(τ)κxFg2Gg(τ)Fg(FrκxFg). 26

In cases where cross talk constitutes a substantial portion of the fluorescence signal in the red channel, as is the case for most combinations using fluorescent proteins (because of the limited availability of far red-emitting FPs), it may be more appropriate to eliminate cross talk already in the measurements, rather than correcting for it retrospectively. Here, alternating excitation schemes have proven to be very powerful. The best known scheme for FCS is pulsed interleaved excitation (Mueller et al. 2005; Sohn et al. 2010), and alternating excitation may also easily be combined with scanning FCS (Ries et al. 2009a).

FCS Applications on Membrane Dynamics

Over the last decade, FCS has been established as an extremely attractive tool for in vivo (Mütze et al. 2009) studies and on model membrane systems (Kahya and Schwille 2006a). Thus, lipid biology has widely exploited this technique. FCS experiments have been designed and appropriate models have been developed to distinguish free diffusion from diffusion in microdomains and meshwork structures in native membranes (Wawrezinieck et al. 2005; Lenne et al. 2006; Wenger et al. 2007). There have been many studies on phase separated model membranes, supported or free-standing, to determine the diffusion characteristics of lipids in different phases (Chiantia et al. 2008, 2009; Lingwood et al. 2008; García-Sáez and Schwille 2010; García-Sáez et al. 2010). It has been shown that the diffusion coefficient is influenced by environmental conditions such as ionic strength or sugar content of the medium (Bockmann et al. 2003; Sum et al. 2003; Doeven et al. 2005; van den Bogaart et al. 2007; Guo et al. 2008; Vacha et al. 2009). The role of cholesterol in membrane organization, a big issue in lipid biology, has been intensively addressed by FCS (Scherfeld et al. 2003; Bacia et al. 2004, 2005; Kahya and Schwile 2006b). Markers for more ordered lipid environments, such as sphingomyelin and ceramide, were other important molecules to be studied (Chiantia et al. 2007, 2008; Eggeling et al. 2009). Other membrane-dependent processes were also successfully investigated by FCS. For instance, the interaction of morphogen Fgf8 with its receptors on the cell surface in living embryos has been quantitatively determined by using scanning FCCS (Ries et al. 2009a; SR Yu e al. 2009). Another derivative of scanning FCS–line-scan FCS–was developed to address the questions related to membrane dynamics (Ries et al. 2009b). Moreover, reconstituted protein–protein interactions on GUV membranes were monitored by using FCCS. For example, active tBID and BCLXLΔCt proteins were found to interact, and it was shown that membrane promotes their interaction (Fig. 7) (García-Sáez et al. 2009). In another example, helix–helix interaction was shown for trans-membrane domains using giant plasma membrane spheres by scanning FCCS (Worch et al. 2010).

Figure 7.

Figure 7.

Stimulation of tBID and BCLXLΔCt intereaction by membrane. Cross-correlation in solution is affected by concentration (A, C), whereas it is not changing and always higher in membrane (B, D). (Image courtesy of Ana García-Sáez.)

The applications of FCS in lipid cell biology have been elaborately reviewed elsewhere (Machan and Hof 2010).

A Comparison between FRAP and FCS for Lateral Diffusion

As seen above, FRAP and FCS are alternative methods to measure lateral diffusion of molecules. Although their specific strengths and shortcomings have been briefly mentioned, a direct comparison may still be helpful for choosing the right technique for a particular experiment.

First, FRAP usually requires higher concentrations than does FCS. Numerically, approximately 100 labeled molecules should be on 1 µm2 to obtain a reliable FRAP curve (Wolf 1989), and with increasing concentrations, the signal-noise ratio can be improved. In contrast, the FCS curve deteriorates with increasing concentration. One labeled molecule in the detection volume of 0.5 fL (which is almost 20 times less than probed by FRAP) is usually sufficient to record a decent FCS curve. FCS has a much better temporal resolution down to submicroseconds, thus can resolve very fast diffusions (Gordon et al. 1995). On the other hand, FCS is not well suited to analyze slow diffusion, which is quite vulnerable to photobleaching. The high temporal resolution makes FCS also much more susceptible to sample-induced noise, such as membrane undulations, or autofluorescent objects floating around. However, FCS derivatives like scanning FCS can overcome these problems to some extent, still preserving the high sensitivity and precision of the method. The main issue about FRAP seems to be the high laser power which may easily destroy the living sample and change the dynamics of the molecular system. Finally, FRAP gives information about immobile fractions whereas FCS cannot.

Förster Resonance Energy Transfer (FRET)

FRET is not really a technique, but rather a well-established photophysical phenomenon used to monitor molecular dynamics and interactions down to the single-molecule level. The idea behind FRET was first proposed by Theodor Förster in 1948 (Förster 1948). The mechanism is based on the energy transfer of an excited fluorescent donor molecule to an acceptor molecule in a nonradiative fashion when they are in close proximity (10–100 Å).

The energy transfer not only depends on the distance between donor and acceptor, but also on the spectral properties of the dyes and the relative orientation of their transition dipole moments. The rate (kt) and the efficiency (E) of the energy transfer in FRET are given by

kt=1τD(R0/r)6, 27
E=11+(r/R0)6, 28

where τD is the donor lifetime in the absence of acceptor, r is the spatial distance between donor and acceptor, and R0 is the Förster distance of the donor/acceptor pair, which is the distance at which the energy transfer efficiency is 50%. As seen, FRET efficiency highly depends on R0, which is given by

R0=(9000QD(ln10)κ2J(λ)128π5n4NA)1/6, 29

where QD is the quantum yield of the donor in the absence of the acceptor, κ2 is the dipole orientation factor, n is the refractive index of the medium, NA is Avogadro’s number, and J is the spectral overlap between the emission spectrum of the donor and the absorption spectrum of the acceptor (Fig. 8). J is calculated as

J(λ)=fD(λ)εA(λ)λ4dλ, 30

where fD is the normalized donor emission spectrum, and εA is the acceptor molar extinction coefficient.

Figure 8.

Figure 8.

Principle of FRET.

The dipole orientation factor κ2 is often assumed to be 2/3, which is valid when the acceptor and donor molecules are freely rotating, and considered to be isotropically oriented during the excited state lifetime. If the donor and acceptor molecules are not free to rotate, then this assumption is not valid anymore. In most cases, however, even modest reorientation of donor and acceptor molecules results in enough orientational averaging that κ2 = 2/3 does not result in a large error in the estimated energy transfer distance, because of the sixth-root dependence of R0 on κ2. Even when κ2 is quite different from 2/3 the error can be associated with a shift in R0, and thus, determinations of changes in relative distance for a particular system are still valid. Fluorescent proteins, for example, do not reorient on a timescale that is faster than their fluorescence lifetime. In this case, 0 ≤ κ2 ≤ 4 is a valid approximation.

There are several ways to detect FRET. Acceptor emission can be detected on donor excitation (Gordon et al. 1998). Because the energy is transferred to the acceptor from the donor, the emission intensity of acceptor is expected to increase on donor excitation. Alternatively, the emission of the donor can be observed while photobleaching the acceptor molecule (Jovin and Arndtjovin 1989; Kenworthy and Edidin 1998; Wouters et al. 1998). When the acceptor is optically saturated, the excitation energy of the donor molecule is no longer used by the acceptor molecule, such that the emission intensity of donor molecule increases on acceptor photobleaching, directly proportional to the FRET rate.

Besides the fluorescence intensity measurements mentioned above, the fluorescence life time of the donor can be also measured. FLIM-FRET is a technique to detect the decrease in the donor’s fluorescence lifetime on energy transfer (Gadella and Jovin 1995; Bastiaens and Squire 1999). This method is quite insensitive to many artifacts which are going to be discussed later, but its main disadvantage is the more involved instrumental setup required to detect on nanosecond timescales. FLIM-FRET appears to be more vulnerable to some artifacts caused by pH, temperature, and ionic strength of the medium, as these factors modify fluorescence lifetimes. However, with the proper controls, this method seems to be the most reliable one among others.

Fluorescence lifetime analysis can be performed in two ways, in time domain and in frequency domain. In the time domain approach, very short (picoseconds to femtoseconds) excitation pulses are used to excite the sample, and the lifetime is measured by collecting the resulting photons over time between the pulses, one by one. On the other hand, sinusoidally modulated light is used to excite the fluorophores in frequency domain. The emission is also sinusoidally modulated at the same frequency as the excitation, but there is a phase shift and reduction in the modulation depth, from which the fluorescence lifetime can be derived.

FRET can also be detected by fluorescence anisotropy (Runnels and Scarlata 1995; Gautier et al. 2001; Clayton et al. 2002; Lidke et al. 2003) which uses linearly polarized light to detect the orientation of the molecules. When there is no energy transfer, the orientation of excited molecule is highly correlated with the orientation of the emitting molecule. However, when there is FRET, the emitting molecules are not only the excited donors but also the acceptors, such that the correlation between the orientations of these two components will decrease remarkably. This method has a unique property to also determine FRET between identical molecules (so-called homo-FRET) which is very crucial in dimerization or oligomerization studies (Bader et al. 2009).

The FRET pair selection is an important issue. Theoretically, pairs are selected based on the spectral overlap criterion discussed above. The closer the spatial distance at closest proximity is expected to be, the larger the spectra may vary. Clearly, detection efficiency is maximized and cross talk minimized for spectrally more distinct probes. The most popular FRET pairs at present are GFP-RFP, CFP-YFP, BFP-GFP, GFP-mCherry for genetically modified proteins. There are also several classical FRET pairs based on chemical dyes, such as Cy3-Cy5 and Alexa488-Cy3. More FRET pairs and their properties can be found elsewhere (Sahoo et al. 2007).

Difficulties and Delicacy

In spite of its attractiveness of being a very intuitive technique with in principle rather straightforward experimental design and readout, FRET in praxis has many caveats to be considered carefully, some which are mentioned below.

To get reliable FRET results, spectral cross talk needs to be minimized. When the acceptor fluorescence intensity is used to assess FRET efficiency, spectral contamination always has to be corrected to some extent. Two major sources of this spectral contamination are the direct excitation of the acceptor, and the leakage of donor emission into the acceptor detection channel. As mentioned above, there is always a trade-off between minimal cross talk and a good spectral overlap factor J. The simplest way to correct for spectral contamination is to test the FRET signal in combinations of only acceptor, only donor and donor/acceptor combination, both with acceptor excitation and donor excitation.

Photoconversion is another problem often encountered with fluorescent proteins. Under certain conditions, emission spectra may change with time (e.g., on high laser power excitation) or sometimes spontaneously as a result of protein maturation. This is critical in FRET measurements, particularly when photobleaching is used as readout. It has been shown that on photobleaching of acceptor YFP, CFP-like emission is created without any FRET (Kirber et al. 2007).

Fluorescence lifetime-based FRET detection is insensitive to many of these problems as the life time is usually independent of excitation intensity. On the other hand, the big practical advantage of FRET as a straightforward and intuitive method to complement imaging is also lost, and the instrumentation gets much more involved.

The interactions of donor or acceptor molecules with other components in the medium should be carefully tested. If there is an unwanted binding of one or both to other molecules, this can produce positive and false negative results. Other problems may arise from too complicated stoichiometry (van den Bogaart et al. 2007) and the impossibility to attach fluorescent tags close enough to the interaction region (Miyawaki and Tsien 2000).

As for other fluorescence techniques, photobleaching should be avoided, as it usually changes the molecular ratio of donor and acceptor, resulting in artifacts of FRET efficiency. The donor should be particularly photostable long enough to transfer its energy. It should also exhibit low polarization anisotropy to eliminate the κ2 deviations.

The brightness of donor and acceptor should ideally be comparable, otherwise resulting in saturation in one channel, or enhanced noise in the other channel due (Piston and Kremers 2007).

Applications of FRET in Lipid Biology

Being such a powerful tool to detect dynamic molecular interaction, FRET has had a strong impact on membrane and lipid research. Particularly, lipid/protein clusters in membranes are interesting topics of study, and there are many applications of FRET in this context. It has been shown that GPI-anchored proteins are enriched in cholesterol-dependent clusters, whereas some putative nonraft proteins are not. Cross-linking of GPI-anchored proteins affects the protein distribution on the membrane and their endocytosis, which highlights the role of immobile, actin-driven nanoclusters in the membrane (Varma and Mayor 1998; Sharma et al. 2004; Goswami et al. 2008). However, there are also some contradicting reports on similar systems, proposing that there are no functional clusters in the cell membrane (Kenworthy and Edidin 1999; Kenworthy et al. 2000; Glebov and Nichols 2004). FLIM-FRET was used to detect the effect of cholesterol depletion on lipid order (Grant et al. 2007) as well as dynamic protein–lipid interactions in live cells (Larijani et al. 2003). TIR-FRET was used to visualize protein–protein interactions on cell membranes and insulin secreting cells (Lam et al. 2010; Sohn et al. 2010). Two-photon FRET was applied to visualize protein–protein colocalization (Mills et al. 2003) and free versus clustered receptor–ligand complexes in the membrane (Wallrabe et al. 2003).

Single-Particle Tracking (SPT)

As discussed above, information on the diffusion of molecules in a membrane can usually be obtained by either FRAP or FCS. However, there are certain disadvantages to both techniques. The lateral resolution of both techniques is limited by the diffraction barrier. Additionally, both techniques have to average over many molecular events to obtain a reliable diffusion time. This averaging, however, masks potential heterogeneities in the diffusion characteristics, induced by, for example, molecular interactions or a heterogeneous membrane environment. Therefore, a technique providing access to the randomly distributed tracks of individual particles is greatly desirable. With the possibility of resolving single molecules, the spatial precision at which lateral detection can be performed is only determined by the number of photons it takes to compute a spot-like image, which can then be fitted with a point-spread function to determine its geometrical center (Toprak et al. 2007).

This approach, which has in past years gained tremendous impact because of the availability of extremely sensitive charge-coupled device (CCD) cameras, is known under the name of single-particle tracking (SPT). The underlying idea is that single particles or even molecules are followed by computer-enhanced video microscopy with a spatial resolution of tens of nanometers and a temporal resolution of tens of milliseconds. Thus, it is a suitable technique to investigate the diffusion characteristics of lipid or membrane-attached proteins, as well as factors influencing lipid dynamics and membrane order.

The first SPT experiment was performed in 1982 by Barak and Webb to follow the lipoprotein receptor (Barak and Webb 1982). Then, nanovid microscopy was developed, in which molecules are labeled with gold nanoparticles which can be more easily tracked by wide-field microscopy (Debrabander et al. 1985, 1991). The technique was further improved in terms of resolution in later years (Schnapp et al. 1988; Sheetz and Kuo 1993). A large body of work on imaging and tracking of single lipid molecules on artificial and cell membranes was further catalyzed by the work by Schütz et al. (1997). Later on, the technique was further developed by to track the particles 3D with different strategies (Digman and Gratton 2009; Katayama et al. 2009; Ragan et al. 2006).

The idea behind the technique is to follow the single-molecule movement over time, record it as trajectories and analyze these trajectories according to the diffusion theory. The main way to analyze the trajectories is to calculate the mean square displacement (MSD) defined as

MSD(τ)=(x(t)x(t+τ))2+(y(t)y(t+τ))2+(z(t)z(t+τ))2, 31

where x, y, and z are the coordinates of the particles, τ is the lag time, and 〈 〉 represents the temporal averaging.

The MSD represents the average distance that the molecule travels during the lag time and is thus directly related to the local mobility of the molecule. Once the trajectories are recorded and the MSD is obtained experimentally, it can be compared with theoretical models as listed in Table 3.

Table 3.

SPT fitting models

Type of diffusion Model
3D free diffusion 6Dt
3D anomalous subdiffusion 6Dtα
3D diffusion with directed motion 6Dt + (Vt)2
2D free diffusion 4Dt
2D anomalous subdiffusion 4Dtα
2D diffusion with directed motion 4Dt + (Vt)2
2D corralled motion r (1−A1e(4A2Dt/r))

Of particular importance in membranes are usually the cases of subdiffusion or confined diffusion, which can be induced by corralling of the diffusing molecules in domains, or any other interactions slowing them down locally. To resolve the dynamics of small local constraints, one trajectory can be divided into different parts, to display the changes in mobility over time.

Instrumentally, SPT can be performed by regular wide-field microscopy, as well as confocal, two-photon, and TIRF. The selection of the illumination method depends on the application.

Different labels can be used in SPT, according to the nature of the experiment and the temporal and spatial scales to be observed. Usually, the spatial precision scales with the signal-to-noise ratio that can be reached, but bright probes such as nanoparticles and beads have to be used with care, as they might also influence the mobility of molecules. The most commonly used labels are gold nanoparticles, quantum dots, and fluorescent microspheres. The most convenient way of labeling is to conjugate the probes with antibodies or adaptor proteins which specifically target the molecule of interest.

After the particle location is accurately determined in x–y or x–y–z (Levi and Gratton 2007), different algorithms can be applied to acquire the full trajectories. The basic algorithms are cross-correlating subsequent images (Gelles et al. 1988; Kusumi et al. 1993), calculating the center-of-mass of the labeled object (Lee et al. 1991; Ghosh and Webb 1994), or directly fitting the image to a Gaussian distribution (Anderson et al. 1992; Schutz et al. 1997). The correlation method compares the image with the Kernel of the successive image. This method gives the best performance at low signal-to-noise ratios. The centroid (center-of-mass) algorithm compares the center of mass of two subsequent images to determine the distance the molecule has travelled in between. A Gaussian fit algorithm directly fits the image of the object to a 2D Gaussian distribution (as an approximation of the PSF):

G(x,y)=Aexp[(xx0)2+(yy0)2B], 32

This algorithm shows the greatest performance when the object is of subwavelength size. A detailed comparison of these algorithms, their potential problems, and performances can be found in Cheezum et al. (2001). There are also algorithms available which combine the correlation and Gaussian fit algorithms (Levi et al. 2006a,b).

Difficulties and Delicacy

There are many aspects to be taken into account to perform meaningful SPT analysis.

First, when using fluorescent probes rather than nanoparticles or beads, photodamage should be minimized. SPT requires a long time to record the trajectories. Therefore, photobleaching can be an important issue. The photostability of quantum dots or fluorescent beads is usually quite high, but when fluorescent lipid analogs or fluorescent proteins are used, the intensity has to be much reduced, limiting the spatial resolution. A very important strategy is to illuminate only while recording the photons, and shutting the laser during camera readout (i.e., frame transfer to the data storage).

A big argument in the SPT field is the effect of large labels on molecular motion. When a bead or nanoparticle is attached to small molecules such as lipids, the diffusion characteristics may change dramatically. Moreover, linkers to attach the label to the molecule can also be problematic. Generally, short linkers and small labels are desirable. Detailed work on this issue can be found in the literature (Dahan et al. 2003).

The determination of particle location is the most crucial aspect in SPT, and much work has been devoted to maximize the spatial precision. The accuracy of the spatial coordinates was in the last years improved drastically, down to 1.5 nm in recent studies (Yildiz et al. 2003, 2004a,b).

The tracking software must be sensitive to the particle brightness changes, because of changes in the particle location with respect to the focal plane. This effect can also be used to record z coordinates with moderate precision (Levi et al. 2005; Ragan et al. 2006). Needless to say, cameras should be fast and sensitive enough to catch the single-molecule signal.

The trajectory algorithm should be carefully chosen, taking all the advantages and disadvantages into consideration. The Gaussian fit algorithm, for instance, seems easy and robust to apply, but it just uses the brightest point as the center and does not take the topographical structure into account. Therefore, it may result in wrong results depending on the molecule topology (Cheezum et al. 2001).

The lag time τ used to record the MSD is also an important variable. It is supposed to be lower than one-fourth of the total trajectory time (Saxton and Jacobson 1997).

Scattering or autofluorescence background is usually quite low, but it decreases the localization accuracy of SPT. It is more dominant when the centroid algorithm is used, because center-of-mass is biased notably by the background (Cheezum et al. 2001; Levi and Gratton 2007).

Applications

SPT hfas been applied successfully to investigate different diffusion mechanisms and establish the models for active transport, free diffusion, anomalous diffusion, and confined diffusion, as seen in Figure 9 and Table 3 (Saxton 1994a,b, 1995, 1996a,b, 1997; Saxton and Jacobson 1997). Lipid diffusion is found to be highly restricted in native plasma membranes, unlike in liposomes, highlighting the role of cytoskeleton in membrane dynamics (Kusumi et al. 2005). Another diffusion type was described according to these observations, called hop diffusion. It is claimed that both lipids and trans-membrane proteins diffuse in small compartments whose boundaries were mostly determined by cytoskeleton of the cell until they change the compartment by hop diffusion (Tomishige et al. 1998). Although there are many studies claiming that saturated lipids and GPI-anchored proteins show confined diffusion on cell membrane on islands of 80 nm and 700 nm in size (Schutz et al. 2000; Lenne et al. 2006; Wenger et al. 2007), some other SPT studies has recently claimed that the diffusion of saturated and unsaturated lipids is not different in cell membrane, which can be because of very small size (<16 nm) or very fast association/dissociation of the rafts. Recently, two-color SPT (Dunne et al. 2009) and micropatterning (Schwarzenbacher et al. 2008) was established to visualize the colocalization on a single-molecule level. A concise summary on many applications can be found elsewhere (Saxton and Jacaobson 1997; Levi and Gratton 2007).

Figure 9.

Figure 9.

SPT models. (a) Active transport, (b) free diffusion, (c) anomalous diffusion, and (d) confined diffusion.

ACKNOWLEDGMENTS

We would like to thank Senthil Arumugan, Fabian Heinemann, Grzegorz Chwastek, and Harekrushna Sahoo for their careful reading of and valuable comments on the manuscript.

Footnotes

Editor: Kai Simons

Additional Perspectives on The Biology of Lipids available at www.cshperspectives.org

REFERENCES

  1. Amos WB, White JG 2003. How the confocal laser scanning microscope entered biological research. Biol Cell 95: 335–342 [DOI] [PubMed] [Google Scholar]
  2. Anderson CM, Georgiou GN, Morrison IEG, Stevenson GVW, Cherry RJ 1992. Tracking of cell-surface receptors by fluorescence digital imaging microscopy using a charge-coupled device camera—Low-density-lipoprotein and influenza-virus receptor mobility at 4°C. J Cell Sci 101: 415–425 [DOI] [PubMed] [Google Scholar]
  3. Aoki R, Kitaguchi T, Oya M, Yanagihara Y, Sato M, Miyawaki A, Tsuboi T 2010. Duration of fusion pore opening and the amount of hormone released are regulated by myosin II during kiss-and-run exocytosis. Biochem J 429: 497–504 [DOI] [PubMed] [Google Scholar]
  4. Axelrod D 1977. Cell-surface heating during fluorescence photobleaching recovery experiments. Biophys J 18: 129–131 [DOI] [PMC free article] [PubMed] [Google Scholar]
  5. Axelrod D 2008. Chapter 7: Total internal reflection fluorescence microscopy. Methods Cell Biology 89: 169–221 [DOI] [PubMed] [Google Scholar]
  6. Axelrod D, Thompson NL, Burghardt TP 1983. Total internal reflection fluorescent microscopy. J Microsc 129: 19–28 [DOI] [PubMed] [Google Scholar]
  7. Axelrod D, Koppel DE, Schlessinger J, Elson E, Webb WW 1976. Mobility measurement by analysis of fluorescence photobleaching recovery kinetics. Biophys J 16: 1055–1069 [DOI] [PMC free article] [PubMed] [Google Scholar]
  8. Bacia K, Schwille P, Kurzchalia T 2005. Sterol structure determines the separation of phases and the curvature of the liquid-ordered phase in model membranes. Proc Natl Acad Sci 102: 3272–3277 [DOI] [PMC free article] [PubMed] [Google Scholar]
  9. Bacia K, Scherfeld D, Kahya N, Schwille P 2004. Fluorescence correlation spectroscopy relates rafts in model and native membranes. Biophys J 87: 1034–1043 [DOI] [PMC free article] [PubMed] [Google Scholar]
  10. Bader AN, Hofman EG, Voortman J, Henegouwen P, Gerritsen HC 2009. Homo-FRET imaging enables quantification of protein cluster sizes with subcellular resolution. Biophys J 97: 2613–2622 [DOI] [PMC free article] [PubMed] [Google Scholar]
  11. Bagatolli LA 2003. Direct observation of lipid domains in free standing bilayers: From simple to complex lipid mixtures. Chem Phys Lipids 122: 137–145 [DOI] [PubMed] [Google Scholar]
  12. Bagatolli LA, Gratton E 1999. Two-photon fluorescence microscopy observation of shape changes at the phase transition in phospholipid giant unilamellar vesicles. Biophys J 77: 2090–2101 [DOI] [PMC free article] [PubMed] [Google Scholar]
  13. Bagatolli LA, Gratton E 2000a. Two photon fluorescence microscopy of coexisting lipid domains in giant unilamellar vesicles of binary phospholipid mixtures. Biophys J 78: 290–305 [DOI] [PMC free article] [PubMed] [Google Scholar]
  14. Bagatolli LA, Gratton E 2000b. A correlation between lipid domain shape and binary phospholipid mixture composition in free standing bilayers: A two-photon fluorescence microscopy study. Biophys J 79: 434–447 [DOI] [PMC free article] [PubMed] [Google Scholar]
  15. Bagatolli LA, Sanchez SA, Hazlett T, Gratton E 2003. Giant vesicles, laurdan, and two-photon fluorescence microscopy: Evidence of lipid lateral separation in bilayers. Biophotonics 360: 481–500 [DOI] [PubMed] [Google Scholar]
  16. Barak LS, Webb WW 1982. Diffusion of low density lipoprotein-receptor complex on human fibroblasts. J Cell Biol 95: 846–852 [DOI] [PMC free article] [PubMed] [Google Scholar]
  17. Bastiaens PIH, Squire A 1999. Fluorescence lifetime imaging microscopy: Spatial resolution of biochemical processes in the cell. Trends Cell Biol 9: 48–52 [DOI] [PubMed] [Google Scholar]
  18. Baumgart T, Hunt G, Farkas ER, Webb WW, Feigenson GW 2007. Fluorescence probe partitioning between Lo/Ld phases in lipid membranes. Biochim Biophys Acta 1768: 2182–2194 [DOI] [PMC free article] [PubMed] [Google Scholar]
  19. Benda A, Benes M, Marecek V, Lhotsky A, Hermens WT, Hof M 2003. How to determine diffusion coefficients in planar phospholipid systems by confocal fluorescence correlation spectroscopy. Langmuir 19: 4120–4126 [Google Scholar]
  20. Bockmann RA, Hac A, Heimburg T, Grubmuller H 2003. Effect of sodium chloride on a lipid bilayer. Biophys J 85: 1647–1655 [DOI] [PMC free article] [PubMed] [Google Scholar]
  21. Boldyrev IA, Zhai XH, Momsen MM, Brockman HL, Brown RE, Molotkovsky JG 2007. New BODIPY lipid probes for fluorescence studies of membranes. J Lipid Res 48: 1518–1532 [DOI] [PMC free article] [PubMed] [Google Scholar]
  22. Brakenhoff GJ, Blom P, Barends P 1979. Confocal scanning light-microscopy with high aperture immersion lenses. J Microsc 117: 219–232 [Google Scholar]
  23. Byrne GD, Pitter MC, Zhang J, Falcone FH, Stolnik S, Somekh MG 2008. Total internal reflection microscopy for live imaging of cellular uptake of sub-micron non-fluorescent particles. J Microsc 231: 168–179 [DOI] [PubMed] [Google Scholar]
  24. Cannon B, Weaver N, Pu QS, Thiagarajan V, Liu SR, Huang JY, Vaughn MW, Cheng KH 2005. Cholesterol modulated antibody binding in supported lipid membranes as determined by total internal reflectance microscopy on a microfabricated high-throughput glass chip. Langmuir 21: 9666–9674 [DOI] [PubMed] [Google Scholar]
  25. Cheezum MK, Walker WF, Guilford WH 2001. Quantitative comparison of algorithms for tracking single fluorescent particles. Biophys J 81: 2378–2388 [DOI] [PMC free article] [PubMed] [Google Scholar]
  26. Chiantia S, Kahya N, Schwille P 2007. Raft domain reorganization driven by short- and long-chain ceramide: A combined AFM and FCS study. Langmuir 23: 7659–7665 [DOI] [PubMed] [Google Scholar]
  27. Chiantia S, Ries J, Schwille P 2009. Fluorescence correlation spectroscopy in membrane structure elucidation. Biochim Biophys Acta 1788: 225–233 [DOI] [PubMed] [Google Scholar]
  28. Chiantia S, Ries J, Chwastek G, Carrer D, Li Z, Bittman R, Schwille P 2008. Role of ceramide in membrane protein organization investigated by combined AFM and FCS. Biochim Biophys Acta 1778: 1356–1364 [DOI] [PubMed] [Google Scholar]
  29. Choucair A, Chakrapani M, Chakravarthy B, Katsaras J, Johnston LJ 2007. Preferential accumulation of A β(1-42) on gel phase domains of lipid bilayers: An AFM and fluorescence study. Biochim Biophys Acta 1768: 146–154 [DOI] [PubMed] [Google Scholar]
  30. Clayton AHA, Hanley QS, Arndt-Jovin DJ, Subramaniam V, Jovin TM 2002. Dynamic fluorescence anisotropy imaging microscopy in the frequency domain (rFLIM). Biophys J 83: 1631–1649 [DOI] [PMC free article] [PubMed] [Google Scholar]
  31. Coban O, Burger M, Laliberte M, Ianoul A, Johnston LJ 2007. Ganglioside partitioning and aggregation in phase-separated monolayers characterized by bodipy GM1 monomer/dimer emission. Langmuir 23: 6704–6711 [DOI] [PubMed] [Google Scholar]
  32. Dahan M, Levi S, Luccardini C, Rostaing P, Riveau B, Triller A 2003. Diffusion dynamics of glycine receptors revealed by single-quantum dot tracking. Science 302: 442–445 [DOI] [PubMed] [Google Scholar]
  33. Davidovi P, Egger MD 1973. Photomicrography of corneal endothelial cells in-vivo. Nature 244: 366–367 [DOI] [PubMed] [Google Scholar]
  34. Davis LM, Shen 2006. Accounting for triplet and saturation effects in FCS measurements. Curr Pharm Biotechnol 7: 287–301 [DOI] [PubMed] [Google Scholar]
  35. Debrabander M, Geuens G, Nuydens R, Moeremans M, Demey J 1985. Probing microtubule-dependent intracellular motility with nanometer particle video ultramicroscopy (nanovid ultramicroscopy). Cytobios 43: 273–283 [PubMed] [Google Scholar]
  36. Debrabander M, Nuydens R, Ishihara A, Holifield B, Jacobson K, Geerts H 1991. Lateral diffusion and retrograde movements of individual cell-surface components on single motile cells observed with nanovid microscopy. J Cell Biol 112: 111–124 [DOI] [PMC free article] [PubMed] [Google Scholar]
  37. Delon A, Usson Y, Derouard J, Biben T, Souchier C 2004. Photobleaching, mobility, and compartmentalisation: Inferences in fluorescence correlation spectroscopy. J Fluorescence 14: 255–267 [DOI] [PubMed] [Google Scholar]
  38. Denk W, Strickler JH, Webb WW 1990. 2-photon laser scanning fluorescence microscopy. Science 248: 73–76 [DOI] [PubMed] [Google Scholar]
  39. Dertinger T, Pacheco V, von der Hocht I, Hartmann R, Gregor I, Enderlein J 2007. Two-focus fluorescence correlation spectroscopy: A new tool for accurate and absolute diffusion measurements. Chemphyschem 8: 433–443 [DOI] [PubMed] [Google Scholar]
  40. Dewa T, Sugiura R, Suemori Y, Sugimoto M, Takeuchi T, Hiro A, Iida K, Gardiner AT, Cogdell RJ, Nango M 2006. Lateral organization of a membrane protein in a supported binary lipid domain: Direct observation of the organization of bacterial light-harvesting complex 2 by total internal reflection fluorescence microscopy. Langmuir 22: 5412–5418 [DOI] [PubMed] [Google Scholar]
  41. Dietrich C, Bagatolli LA, Volovyk ZN, Thompson NL, Levi M, Jacobson K, Gratton E 2001. Lipid rafts reconstituted in model membranes. Biophys J 80: 1417–1428 [DOI] [PMC free article] [PubMed] [Google Scholar]
  42. Digman MA, Gratton E 2009. Imaging barriers to diffusion by pair correlation functions. Biophys J 97: 665–673 [DOI] [PMC free article] [PubMed] [Google Scholar]
  43. Dittrich PS, Schwille P 2001. Photobleaching and stabilization of fluorophores used for single-molecule analysis with one- and two-photon excitation. Appl Phys B 73: 829–837 [Google Scholar]
  44. Doeven MK, Folgering JHA, Krasnikov V, Geertsma ER, van den Bogaart G, Poolman B 2005. Distribution, lateral mobility and function of membrane proteins incorporated into giant unilamellar vesicles. Biophys J 88: 1134–1142 [DOI] [PMC free article] [PubMed] [Google Scholar]
  45. Dunne PD, Fernandes RA, McColl J, Yoon JW, James JR, Davis SJ, Klenerman D 2009. DySCo: Quantitating associations of membrane proteins using two-color single-molecule tracking. Biophys J 97: L5–L7 [DOI] [PMC free article] [PubMed] [Google Scholar]
  46. Edidin M 1992. Patches, posts and fences: Proteins and plasma membrane domains. Trends Cell Biol 2: 376–380 [DOI] [PubMed] [Google Scholar]
  47. Egger MD, Petran M 1967. New reflected-light microscope for viewing unstained brain and ganglion cells. Science 157: 305–307 [DOI] [PubMed] [Google Scholar]
  48. Eggeling C, Ringemann C, Medda R, Schwarzmann G, Sandhoff K, Polyakova S, Belov VN, Hein B, von Middendorff C, Schonle A, et al. 2009. Direct observation of the nanoscale dynamics of membrane lipids in a living cell. Nature 457: U1159–U1121 [DOI] [PubMed] [Google Scholar]
  49. Eigen M, Rigler R 1994. Sorting single molecules—Application to diagnostics and evolutionary biotechnology. Proc Natl Acad Sci 91: 5740–5747 [DOI] [PMC free article] [PubMed] [Google Scholar]
  50. Ellenberg J, Siggia ED, Moreira JE, Smith CL, Presley JF, Worman HJ, Lippincott-Schwartz J 1997. Nuclear membrane dynamics and reassembly in living cells: Targeting of an inner nuclear membrane protein in interphase and mitosis. J Cell Biol 138: 1193–1206 [DOI] [PMC free article] [PubMed] [Google Scholar]
  51. Elson EL, Magde D 1974. Fluorescence correlation spectroscopy. 1. Conceptual basis and theory. Biopolymers 13: 1–27 [DOI] [PubMed] [Google Scholar]
  52. Enderlein J, Gregor I, Patra D, Dertinger T, Kaupp UB 2005. Performance of fluorescence correlation spectroscopy for measuring diffusion and concentration. Chemphyschem 6: 2324–2336 [DOI] [PubMed] [Google Scholar]
  53. Enderlein J, Gregor I, Patra D, Fitter J 2004. Art and artefacts of fluorescence correlation spectroscopy. Curr Pharmaceut Biotech 5: 155–161 [DOI] [PubMed] [Google Scholar]
  54. Engelke M, Bojarski P, Bloss R, Diehl H 2001. Tamoxifen perturbs lipid bilayer order and permeability: Comparison of DSC, fluorescence anisotropy, Laurdan generalized polarization and carboxyfluorescein leakage studies. Biophys Chem 90: 157–173 [DOI] [PubMed] [Google Scholar]
  55. Feder TJ, BrustMascher I, Slattery JP, Baird B, Webb WW 1996. Constrained diffusion or immobile fraction on cell surfaces: A new interpretation. Biophysical J 70: 2767–2773 [DOI] [PMC free article] [PubMed] [Google Scholar]
  56. Förster T 1948. Intermolecular energy migration and fluorescence. Ann Phys 2: 55–75 [Google Scholar]
  57. Fox CB, Wayment JR, Myers GA, Endicott SK, Harris JM 2009. Single-molecule fluorescence imaging of peptide binding to supported lipid bilayers. Anal Chem 81: 5130–5138 [DOI] [PubMed] [Google Scholar]
  58. Fulbright RM, Axelrod D 1993. Dynamics of nonspecific adsorption of insulin to erythrocyte membrane. J Fluor 3: 1–16 [DOI] [PubMed] [Google Scholar]
  59. Gadella TWJ, Jovin TM 1995. Oligomerization of epidermal growth-factor receptors on a431 cells studied by time-resolved fluorescence imaging microscopy—A stereochemical model for tyrosine kinase receptor activation. J Cell Biol 129: 1543–1558 [DOI] [PMC free article] [PubMed] [Google Scholar]
  60. García-Sáez AJ, Schwille P 2010. Stability of lipid domains. FEBS Lett 584: 1653–1658 [DOI] [PubMed] [Google Scholar]
  61. García-Sáez AJ, Ries J, Orzaez M, Perez-Paya E, Schwille P 2009. Membrane promotes tBID interaction with BCLXL. Nat Struct Mol Biol 16: U1178–U1179 [DOI] [PubMed] [Google Scholar]
  62. García-Sáez AJ, Carrer DC, Schwille P 2010. Fluorescence correlation spectroscopy for the study of membrane dynamics and organization in giant unilamellar vesicles. Meth Mol Biol 606: 493–508 [DOI] [PubMed] [Google Scholar]
  63. Gasecka A, Han TJ, Favard C, Cho BR, Brasselet S 2009. Quantitative imaging of molecular order in lipid membranes using two-photon fluorescence polarimetry. Biophys J 97: 2854–2862 [DOI] [PMC free article] [PubMed] [Google Scholar]
  64. Gautier I, Tramier M, Durieux C, Coppey J, Pansu RB, Nicolas JC, Kemnitz K, Coppey-Moisan M 2001. Homo-FRET microscopy in living cells to measure monomer-dimer transition of GFP-tagged proteins. Biophys J 80: 3000–3008 [DOI] [PMC free article] [PubMed] [Google Scholar]
  65. Gelles J, Schnapp BJ, Sheetz MP 1988. Tracking kinesin-driven movements with nanometre-scale precision. Nature 331: 450–453 [DOI] [PubMed] [Google Scholar]
  66. Ghosh RN, Webb WW 1994. Automated detection and tracking of individual and clustered cell-surface low-density-lipoprotein receptor molecules. Biophys J 66: 1301–1318 [DOI] [PMC free article] [PubMed] [Google Scholar]
  67. Gidwani A, Holowka D, Baird B 2001. Fluorescence anisotropy measurements of lipid order in plasma membranes and lipid rafts from RBL-2H3 mast cells. Biochemistry 40: 12422–12429 [DOI] [PubMed] [Google Scholar]
  68. Glebov OO, Nichols BJ 2004. Lipid raft proteins have a random distribution during localized activation of the T-cell receptor. Nat Cell Biol 6: 238–243 [DOI] [PubMed] [Google Scholar]
  69. Goodwin JS, Drake KR, Remmert CL, Kenworthy AJ 2005. Ras diffusion is sensitive to plasma membrane viscosity. Biophys J 89: 1398–1410 [DOI] [PMC free article] [PubMed] [Google Scholar]
  70. Goppert M 1929. Über die Wahrscheinlichkeit des Zusammenwirkens zweier Lichtquanten in einem Elementarakt. Naturwissenschaften 17: 932–932 [Google Scholar]
  71. Gordon GW, Berry G, Liang XH, Levine B, Herman B 1998. Quantitative fluorescence resonance energy transfer measurements using fluorescence microscopy. Biophys J 74: 2702–2713 [DOI] [PMC free article] [PubMed] [Google Scholar]
  72. Gordon GW, Chazotte B, Wang XF, Herman B 1995. Analysis of simulated and experimental fluorescence recovery after photobleaching. Data for two diffusing components. Biophys J 68: 766–778 [DOI] [PMC free article] [PubMed] [Google Scholar]
  73. Gorg B, Morwinsky A, Keitel V, Qvartskhava N, Schror K, Haussinger D 2010. Ammonia triggers exocytotic release of l-glutamate from cultured rat astrocytes. Glia 58: 691–705 [DOI] [PubMed] [Google Scholar]
  74. Goswami D, Gowrishankar K, Bilgrami S, Ghosh S, Raghupathy R, Chadda R, Vishwakarma R, Rao M, Mayor S 2008. Nanoclusters of GPI-anchored proteins are formed by cortical actin-driven activity. Cell 135: 1085–1097 [DOI] [PMC free article] [PubMed] [Google Scholar]
  75. Grant DM, McGinty J, McGhee EJ, Bunney TD, Owen DM, Talbot CB, Zhang W, Kumar S, Munro I, Lanigan PMP, et al. 2007. High speed optically sectioned fluorescence lifetime imaging permits study of live cell signaling events. Opt Exp 15: 15656–15673 [DOI] [PubMed] [Google Scholar]
  76. Gregor I, Patra D, Enderlein J 2005. Optical saturation in fluorescence correlation spectroscopy under continuous-wave and pulsed excitation. Chemphyschem 6: 164–170 [DOI] [PubMed] [Google Scholar]
  77. Guo L, Har JY, Sankaran J, Hong YM, Kannan B, Wohland T 2008. Molecular diffusion measurement in lipid bilayers over wide concentration ranges: A comparative study. Chemphyschem 9: 721–728 [DOI] [PubMed] [Google Scholar]
  78. Hamilton DK, Wilson T 1986. Scanning optical microscopy by objective lens scanning. J Phys E-Scientific Instruments 19: 52–54 [Google Scholar]
  79. Hao MM, Mukherjee S, Maxfield FR 2001. Cholesterol depletion induces large scale domain segregation in living cell membranes. Proc Natl Acad Sci 98: 13072–13077 [DOI] [PMC free article] [PubMed] [Google Scholar]
  80. Haupts U, Maiti S, Schwille P, Webb WW 1998. Dynamics of fluorescence fluctuations in green fluorescent protein observed by fluorescence correlation spectroscopy. Proc Natl Acad Sci 95: 13573–13578 [DOI] [PMC free article] [PubMed] [Google Scholar]
  81. Hein B, Willig KI, Hell SW 2008. Stimulated emission depletion (STED) nanoscopy of a fluorescent protein-labeled organelle inside a living cell. Proc Natl Acad Sci 105: 14271–14276 [DOI] [PMC free article] [PubMed] [Google Scholar]
  82. Heinze KG, Koltermann A, Schwille P 2000. Simultaneous two-photon excitation of distinct labels for dual-color fluorescence crosscorrelation analysis. Proc Natl Acad Sci 97: 10377–10382 [DOI] [PMC free article] [PubMed] [Google Scholar]
  83. Heinze KG, Rarbach M, Jahnz M, Schwille P 2002. Two-photon fluorescence coincidence analysis: Rapid measurements of enzyme kinetics. Biophys J 83: 1671–1681 [DOI] [PMC free article] [PubMed] [Google Scholar]
  84. Hellen E, Axelrod D 1991. Kinetics of epidermal growth factor/receptor binding on cells measured by total internal reflection/fluorescence recovery after photobleaching. J Fluor 1: 113–128 [DOI] [PubMed] [Google Scholar]
  85. Hellwarth R, Christensen P 1975. Nonlinear optical microscope using second-harmonic generation. Appl Opt 14: 247–248 [DOI] [PubMed] [Google Scholar]
  86. Hess ST, Webb WW 2002. Focal volume optics and experimental artifacts in confocal fluorescence correlation spectroscopy. Biophys J 83: 2300–2317 [DOI] [PMC free article] [PubMed] [Google Scholar]
  87. Holtta-Vuori M, Uronen FL, Repakova J, Salonen E, Vattulainen I, Panula P, Li ZG, Bittman R, Ikonen E 2008. BODIPY-cholesterol: A new tool to visualize sterol trafficking in living cells and organisms. Traffic 9: 1839–1849 [DOI] [PubMed] [Google Scholar]
  88. Honerkamp-Smith AR, Cicuta P, Collins MD, Veatch SL, den Nijs M, Schick M, Keller SL 2008. Line tensions, correlation lengths, and critical exponents in lipid membranes near critical points. Biophys J 95: 236–246 [DOI] [PMC free article] [PubMed] [Google Scholar]
  89. Honigmann A, Walter C, Erdmann F, Eggeling C, Wagner R 2010. Characterization of horizontal lipid bilayers as a model system to study lipid phase separation. Biophys J 98: 2886–2894 [DOI] [PMC free article] [PubMed] [Google Scholar]
  90. Humpolickova J, Benda A, Enderlein J 2009. Optical saturation as a versatile tool to enhance resolution in confocal microscopy. Biophys J 97: 2623–2629 [DOI] [PMC free article] [PubMed] [Google Scholar]
  91. Humpolickova J, Gielen E, Benda A, Fagulova V, Vercammen J, Vandeven M, Hof M, Ameloot M, Engelborghs Y 2006. Probing diffusion laws within cellular membranes by Z-scan fluorescence correlation spectroscopy. Biophys J 91: L23–L25 [DOI] [PMC free article] [PubMed] [Google Scholar]
  92. Icenogle RD, Elson EL 1983a. Fluorescence correlation spectroscopy and photobleaching recovery of multiple binding reactions. 1. Theory and FCS measurements. Biopolymers 22: 1919–1948 [DOI] [PubMed] [Google Scholar]
  93. Icenogle RD, Elson EL 1983b. Fluorescence correlation spectroscopy and photobleaching recovery of multiple binding reactions. 2. FPR AND FCS measurements at low and high DNA concentrations. Biopolymers 22: 1949–1966 [DOI] [PubMed] [Google Scholar]
  94. Ira S Zou, Ramirez DMC, Vanderlip S, Ogilvie W, Jakubek ZJ, Johnston LJ 2009. Enzymatic generation of ceramide induces membrane restructuring: Correlated AFM and fluorescence imaging of supported bilayers. J Struct Biol 168: 78–89 [DOI] [PubMed] [Google Scholar]
  95. Jacobson K, Sheets ED, Simson R 1995. Revisiting the fluid mosaic model of membranes. Science 268: 1441–1442 [DOI] [PubMed] [Google Scholar]
  96. Jin L, Millard AC, Wuskell JP, Dong XM, Wu DQ, Clark HA, Loew LM 2006. Characterization and application of a new optical probe for membrane lipid domains. Biophys J 90: 2563–2575 [DOI] [PMC free article] [PubMed] [Google Scholar]
  97. Johnson SA, Stinson BM, Go MS, Carmona LM, Reminick JI, Fang X, Baumgart T 2010. Temperature-dependent phase behavior and protein partioning in giant plasma membrane vesicles. Biochim Biophys Acta 1798: 1427–1435 [DOI] [PMC free article] [PubMed] [Google Scholar]
  98. Jorgensen L, Wood GK, Rosenkrands I, Petersen C, Christensen D 2009. Protein adsorption and displacement at lipid layers determined by total internal reflection fluorescence (TIRF). J Lipo Res 19: 99–104 [DOI] [PubMed] [Google Scholar]
  99. Joselevitch C, Zenisek D 2009. Imaging exocytosis in retinal bipolar cells with TIRF microscopy. J Vis Exp 9: 1305. [DOI] [PMC free article] [PubMed] [Google Scholar]
  100. Jovin TM, Arndtjovin DJ 1989. Luminescence digital imaging microscopy. Annu Rev Biophys Biophys Chem 18: 271–308 [DOI] [PubMed] [Google Scholar]
  101. Juhasz J, Davis JH, Sharom FJ 2010. Fluorescent probe partitioning in giant unilamellar vesicles of ‘lipid raft’ mixtures. Biochem J 430: 415–423 [DOI] [PubMed] [Google Scholar]
  102. Kaiser W, Garrett CGB 1961. Two-photon excitation in CaF2: Eu2+. Phys Rev Lett 7: 229 [Google Scholar]
  103. Kahya N, Schwille P 2006a. Fluorescence correlation studies of lipid domains in model membranes (Review). Mol Membr Biol 23: 29–39 [DOI] [PubMed] [Google Scholar]
  104. Kahya N, Schwille P 2006b. How phospholipid-cholesterol interactions modulate lipid lateral diffusion, as revealed by fluorescence correlation spectroscopy. J Fluorescence 16: 671–678 [DOI] [PubMed] [Google Scholar]
  105. Kahya N, Scherfeld D, Bacia K, Poolman B, Schwille P 2003. Probing lipid mobility of raft-exhibiting model membranes by fluorescence correlation spectroscopy. J Biol Chem 278: 28109–28115 [DOI] [PubMed] [Google Scholar]
  106. Kahya N, Scherfeld D, Bacia K, Schwille P 2004. Lipid domain formation and dynamics in giant unilamellar vesicles explored by fluorescence correlation spectroscopy. J Struct Biol 147: 77–89 [DOI] [PubMed] [Google Scholar]
  107. Kaiser HJ, Lingwood D, Levental I, Sampaio JL, Kalvodova L, Rajendran L, Simons K 2009. Order of lipid phases in model and plasma membranes. Proc Natl Acad Sci 106: 16645–16650 [DOI] [PMC free article] [PubMed] [Google Scholar]
  108. Katayama Y, Burkacky O, Meyer M, Brauchle C, Gratton E, Lamb DC 2009. Real-time nanomicroscopy via three-dimensional single-particle tracking. Chemphyschem 10: 2458–2464 [DOI] [PMC free article] [PubMed] [Google Scholar]
  109. Kenworthy AK 2005. Fleeting glimpses of lipid rafts: How biophysics is being used to track them. J Invest Med 53: 312–317 [DOI] [PubMed] [Google Scholar]
  110. Kenworthy AK 2007. Fluorescence recovery after photobleaching studies of lipid rafts. Methods Mol Biol 398: 179–192 [DOI] [PubMed] [Google Scholar]
  111. Kenworthy AK, Edidin M 1998, Distribution of a glycosylphosphatidylinositol-anchored protein at the apical surface of MDCK cells examined at a resolution of <100 angstrom using imaging fluorescence resonance energy transfer. J Cell Biol 142: 69–84 [DOI] [PMC free article] [PubMed] [Google Scholar]
  112. Kenworthy AK, Edidin M 1999. Imaging fluorescence resonance energy transfer as probe of membrane organization and molecular associations of GPI-anchored proteins. Methods Mol Biol 116: 37–49 [DOI] [PubMed] [Google Scholar]
  113. Kenworthy AK, Nichols BJ, Remmert CL, Hendrix GM, Kumar M, Zimmerberg J, Lippincott-Schwartz J 2004. Dynamics of putative raft-associated proteins at the cell surface. J Cell Biol 165: 735–746 [DOI] [PMC free article] [PubMed] [Google Scholar]
  114. Kenworthy AK, Petranova N, Edidin M 2000. High-resolution FRET microscopy of cholera toxin B-subunit and GPI-anchored proteins in cell plasma membranes. Mol Biol Cell 11: 1645–1655 [DOI] [PMC free article] [PubMed] [Google Scholar]
  115. Kim SA, Heinze KG, Schwille P 2007. Fluorescence correlation spectroscopy in living cells. Nat Methods 4: 963–973 [DOI] [PubMed] [Google Scholar]
  116. Kim HM, Choo HJ, Jung SY, Ko YG, Park WH, Jeon SJ, Kim CH, Joo TH, Cho BR 2007. A two-photon fluorescent probe for lipid raft imaging: C-laurdan. Chembiochem 8: 553–559 [DOI] [PubMed] [Google Scholar]
  117. Kim HM, Jeong BH, Hyon JY, An MJ, Seo MS, Hong JH, Lee KJ, Kim CH, Joo TH, Hong SC, et al. 2008. Two-photon fluorescent turn-on probe for lipid rafts in live cell and tissue. J Am Chem Soc 130: 4246–4247 [DOI] [PubMed] [Google Scholar]
  118. Kirber MT, Chen K, Keaney JF 2007. YFP photoconversion revisited: Confirmation of the CFP-like species. Nat Methods 4: 767–768 [DOI] [PubMed] [Google Scholar]
  119. Koppel DE, Axelrod D, Schlessinger J, Elson EL, Webb WW 1976. Dynamics of fluorescence marker concentration as a probe of mobility. Biophys J 16: 1315–1329 [DOI] [PMC free article] [PubMed] [Google Scholar]
  120. Korlach J, Schwille P, Webb WW, Feigenson GW 1999. Characterization of lipid bilayer phases by confocal microscopy and fluorescence correlation spectroscopy. Proc Natl Acad Sci 96: 8461–8466 [DOI] [PMC free article] [PubMed] [Google Scholar]
  121. Kuerschner L, Ejsing CS, Ekroos K, Shevchenko A, Anderson KI, Thiele C 2005. Polyene-lipids: A new tool to image lipids. Nat Methods 2: 39–45 [DOI] [PubMed] [Google Scholar]
  122. Klymchenko AS, Oncul S, Didier P, Schaub E, Bagatolli L, Duportail G, Mely Y 2009. Visualization of lipid domains in giant unilamellar vesicles using an environment-sensitive membrane probe based on 3-hydroxyflavone. Biochim Biophys Acta 1788: 495–499 [DOI] [PubMed] [Google Scholar]
  123. Kusumi A, Sako Y, Yamamoto M 1993. Confined lateral diffusion of membrane-receptors as studied by single-particle tracking (NANOVID microscopy)—Effects of calcium-induced differentiation in cultured epithelial-cells. Biophys J 65: 2021–2040 [DOI] [PMC free article] [PubMed] [Google Scholar]
  124. Kusumi A, Nakada C, Ritchie K, Murase K, Suzuki K, Murakoshi H, Kasai RS, Kondo J, Fujiwara T 2005. Paradigm shift of the plasma membrane concept from the two-dimensional continuum fluid to the partitioned fluid: High-speed single-molecule tracking of membrane molecules. Annu Rev Biophys Biomol Struct 34: U351–U354 [DOI] [PubMed] [Google Scholar]
  125. Lagerholm BC, Weinreb GE, Jacobson K, Thompson NL 2005. Detecting microdomains in intact cell membranes. Annu Rev Phys Chem 56: 309–336 [DOI] [PubMed] [Google Scholar]
  126. Lam AD, Ismail S, Wu R, Yizhar O, Passmore DR, Ernst SA, Stuenkel EL 2010. Mapping dynamic protein interactions to insulin secretory granule behavior with TIRF-FRET. Biophys J 99: 1311–1320 [DOI] [PMC free article] [PubMed] [Google Scholar]
  127. Larijani B, Allen-Baume V, Morgan CP, Li M, Cockcroft S 2003. EGF regulation of PITP dynamics is blocked by inhibitors of phospholipase C and of the Ras-MAP kinase pathway. Curr Biol 13: 78–84 [DOI] [PubMed] [Google Scholar]
  128. Lee GM, Ishihara A, Jacobson KA 1991. Direct observation of Brownian-motion of lipids in a membrane. Proc Natl Acad Sci 88: 6274–6278 [DOI] [PMC free article] [PubMed] [Google Scholar]
  129. Lenne PF, Wawrezinieck L, Conchonaud F, Wurtz O, Boned A, Guo XJ, Rigneault H, He HT, Marguet D 2006. Dynamic molecular confinement in the plasma membrane by microdomains and the cytoskeleton meshwork. EMBO J 25: 3245–3256 [DOI] [PMC free article] [PubMed] [Google Scholar]
  130. Levi V, Gratton E 2007. Exploring dynamics in living cells by tracking single particles. Cell Biochem Biophys 48: 1–15 [DOI] [PubMed] [Google Scholar]
  131. Levi V, Ruan QQ, Gratton E 2005. 3-D particle tracking in a two-photon microscope: Application to the study of molecular dynamics in cells, Biophys J 88: 2919–2928 [DOI] [PMC free article] [PubMed] [Google Scholar]
  132. Levi V, Gelfand VI, Serpinskaya AS, Gratton E 2006a. Melanosomes transported by myosin-V in Xenopus melanophores perform slow 35 nm steps. Biophys J 90: L7–L9 [DOI] [PMC free article] [PubMed] [Google Scholar]
  133. Levi V, Serpinskaya AS, Gratton E, Gelfand V 2006b. Organelle transport along microtubules in Xenopus melanophores: Evidence for cooperation between multiple motors. Biophys J 90: 318–327 [DOI] [PMC free article] [PubMed] [Google Scholar]
  134. Lidke DS, Nagy P, Barisas BG, Heintzmann R, Post JN, Lidke KA, Clayton AHA, Arndt-Jovin DJ, Jovin TM 2003. Imaging molecular interactions in cells by dynamic and static fluorescence anisotropy (rFLIM and emFRET). Biochem Soc Trans 31: 1020–1027 [DOI] [PubMed] [Google Scholar]
  135. Lingwood D, Ries J, Schwille P, Simons K 2008. Plasma membranes are poised for activation of raft phase coalescence at physiological temperature. Proc Natl Acad Sci 105: 10005–10010 [DOI] [PMC free article] [PubMed] [Google Scholar]
  136. Lippincott-Schwartz J, Snapp E, Kenworthy A 2001. Studying protein dynamics in living cells. Nat Cell Biol 2: 444–456 [DOI] [PubMed] [Google Scholar]
  137. Lippincott-Schwartz J, Altan-Bonnet N, Patterson GH 2003. Photobleaching and photoactivation: Following protein dynamics in living cells. Nat Cell Biol Suppl: S7–S14 [PubMed] [Google Scholar]
  138. Loman A, Dertinger T, Koberling F, Enderlein J 2008. Comparison of optical saturation effects in conventional and dual-focus fluorescence correlation spectroscopy. Chem Phys Lett 459: 18–21 [Google Scholar]
  139. Lommerse PHM, Spaink HP, Schmidt T 2004. In vivo plasma membrane organization: Results of biophysical approaches. Biochim Biophys Acta 1664: 119–131 [DOI] [PubMed] [Google Scholar]
  140. Machan R, Hof M 2010. Lipid diffusion in planar membranes investigated by fluorescence correlation spectroscopy. Biochim Biophys Acta 1798: 1377–1391 [DOI] [PubMed] [Google Scholar]
  141. Magde D, Elson EL, Webb WW 1974. Fluorescence correlation spectroscopy. 2. Experimental realization. Biopolymers 13: 29–61 [DOI] [PubMed] [Google Scholar]
  142. Magde D, Webb WW, Elson E 1972. Thermodynamic fluctuations in a reacting system—Measurement by fluorescence correlation spectroscopy. Phys Rev Lett 29: 705 [Google Scholar]
  143. Magde D, Webb WW, Elson EL 1978. Fluorescence correlation spectroscopy. 3. Uniform translation and laminar-flow. Biopolymers 17: 361–376 [DOI] [PubMed] [Google Scholar]
  144. Marks DL, Bittman R, Pagano RE 2008. Use of Bodipy-labeled sphingolipid and cholesterol analogs to examine membrane microdomains in cells. Histochem Cell Biol 130: 819–832 [DOI] [PMC free article] [PubMed] [Google Scholar]
  145. Meder D, Moreno MJ, Verkade P, Vaz WLC, Simons K 2006. Phase coexistence and connectivity in the apical membrane of polarized epithelial cells. Proc Natl Acad Sci 103: 329–334 [DOI] [PMC free article] [PubMed] [Google Scholar]
  146. Merrifield CJ, Perrais D, Zenisek D 2005. Coupling between clathrin-coated-pit invagination, cortactin recruitment, and membrane scission observed in live cells. Cell 121: 593–606 [DOI] [PubMed] [Google Scholar]
  147. Merrifield CJ, Feldman ME, Wan L, Almers W 2002. Imaging actin and dynamin recruitment during invagination of single clathrin-coated pits. Nat Cell Biol 4: 691–698 [DOI] [PubMed] [Google Scholar]
  148. Meseth U, Wohland T, Rigler R, Vogel H 1999. Resolution of fluorescence correlation measurements. Biophys J 76: 1619–1631 [DOI] [PMC free article] [PubMed] [Google Scholar]
  149. Middlebrook JL, Dorland RB 1984. Bacterial toxins—Cellular mechanisms of action. Microbiological Rev 48: 199–221 [DOI] [PMC free article] [PubMed] [Google Scholar]
  150. Mikhalyov I, Gretskaya N, Johansson LBA 2009. Fluorescent BODIPY-labelled GM1 gangliosides designed for exploring lipid membrane properties and specific membrane–target interactions. Chem Phys Lipids 159: 38–44 [DOI] [PubMed] [Google Scholar]
  151. Mills JD, Stone JR, Rubin DG, Melon DE, Okonkwo DO, Periasamy A, Helm GA 2003. Illuminating protein interactions in tissue using confocal and two-photon excitation fluorescent resonance energy transfer microscopy. J Biomed Opt 8: 347–356 [DOI] [PubMed] [Google Scholar]
  152. Miyawaki A, Tsien RY 2000. Monitoring protein conformations and interactions by fluorescence resonance energy transfer between mutants of green fluorescent protein. Appl Chim Genes Hybrid Prot Pt B 327: 472–500 [DOI] [PubMed] [Google Scholar]
  153. Mueller BK, Zaychikov E, Brauchle C, Lamb DC 2005. Pulsed interleaved excitation. Biophys J 89: 3508–3522 [DOI] [PMC free article] [PubMed] [Google Scholar]
  154. Mütze J, Ohrt T, Schwille P 2011. Fluorescence correlation spectroscopy in vivo. Laser Photon Rev 5: 52–67 [Google Scholar]
  155. Nagamatsu S, Ohara-Imaizumi M 2008. Imaging exocytosis of single insulin secretory granules with TIRF microscopy. Methods Mol Biol 440: 259–268 [DOI] [PubMed] [Google Scholar]
  156. Nicolau DV, Burrage K, Parton RG, Hancock JF 2006. Identifying optimal lipid raft characteristics required to promote nanoscale protein–protein interactions on the plasma membrane. Mol Cell Biol 26: 313–323 [DOI] [PMC free article] [PubMed] [Google Scholar]
  157. Niv H, Gutman O, Henis YI, Kloog Y 1999. Membrane interactions of a constitutively active GFP-Ki-Ras 4B and their role in signaling—Evidence from lateral mobility studies. J Biol Chem 274: 1606–1613 [DOI] [PubMed] [Google Scholar]
  158. Niv H, Gutman O, Kloog Y, Henis YI 2002. Activated K-Ras and H-Ras display different interactions with saturable nonraft sites at the surface of live cells. J Cell Biol 157: 865–872 [DOI] [PMC free article] [PubMed] [Google Scholar]
  159. Ohara-Imaizumi M, Aoyagi K, Akimoto Y, Nakamichi Y, Nishiwaki C, Kawakami H, Nagamatsu S 2009. Imaging exocytosis of single glucagon-like peptide-1 containing granules in a murine enteroendocrine cell line with total internal reflection fluorescent microscopy. Biochem Biophys Res Comm 390: 16–20 [DOI] [PubMed] [Google Scholar]
  160. Oreopoulos J, Yip CM 2009. Probing membrane order and topography in supported lipid bilayers by combined polarized total internal reflection fluorescence–atomic force microscopy. Biophys J 96: 1970–1984 [DOI] [PMC free article] [PubMed] [Google Scholar]
  161. Parasassi T, Gratton E, Yu WM, Wilson P, Levi M 1997. Two-photon fluorescence microscopy of Laurdan generalized polarization domains in model and natural membranes. Biophys J 72: 2413–2429 [DOI] [PMC free article] [PubMed] [Google Scholar]
  162. Petersen NO 1986. Scanning fluorescence correlation spectroscopy. 1. Theory and simulation of aggregation measurements. Biophys J 49: 809–815 [DOI] [PMC free article] [PubMed] [Google Scholar]
  163. Petersen NO, Johnson DC, Schlesinger MJ 1986. Scanning fluorescence correlation spectroscopy. 2. Application to virus glycoprotein aggregation. Biophys J 49: 817–820 [DOI] [PMC free article] [PubMed] [Google Scholar]
  164. Petrasek Z, Schwille P 2008. Precise measurement of diffusion coefficients using scanning fluorescence correlation spectroscopy. Biophys J 94: 1437–1448 [DOI] [PMC free article] [PubMed] [Google Scholar]
  165. Petrasek Z, Ries J, Schwille P 2010. Scanning FCS for the characterization of protein dynamics in live cells. Meth Enzymol 472: 317–343 [DOI] [PubMed] [Google Scholar]
  166. Petrov E, Schwille P 2007. State of the art and novel trends in fluorescence correlation spectroscopy. In Standardization and quality assurance in fluorescence measurements II (ed. Resch-Genger U), pp. 145–197 Springer-Verlag, Berlin [Google Scholar]
  167. Phair RD, Gorski SA, Misteli T 2004. Measurement of dynamic protein binding to chromatin in vivo, using photobleaching microscopy. Methods Enzymol 375: 393–414 [DOI] [PubMed] [Google Scholar]
  168. Pinaud F, Michalet X, Iyer G, Margeat E, Moore HP, Weiss S 2009. Dynamic partitioning of a glycosyl-phosphatidylinositol-anchored protein in glycosphingolipid-rich microdomains imaged by single-quantum dot tracking. Traffic 10: 691–712 [DOI] [PMC free article] [PubMed] [Google Scholar]
  169. Piston DW, Kremers GJ 2007. Fluorescent protein FRET: The good, the bad and the ugly. Trends Biochem Sci 32: 407–414 [DOI] [PubMed] [Google Scholar]
  170. Ragan T, Huang HD, So P, Gratton E 2006. 3D particle tracking on a two-photon microscope. J Fluorescence 16: 325–336 [DOI] [PubMed] [Google Scholar]
  171. Ries J, Schwille P 2006. Studying slow membrane dynamics with continuous wave scanning fluorescence correlation spectroscopy. Biophys J 91: 1915–1924 [DOI] [PMC free article] [PubMed] [Google Scholar]
  172. Ries J, Chiantia S, Schwille P 2009b. Accurate determination of membrane dynamics with line-scan FCS. Biophys J 96: 1999–2008 [DOI] [PMC free article] [PubMed] [Google Scholar]
  173. Ries J, Petrov EP, Schwille P 2008. Total internal reflection fluorescence correlation spectroscopy: Effects of lateral diffusion and surface-generated fluorescence. Biophys J 95: 390–399 [DOI] [PMC free article] [PubMed] [Google Scholar]
  174. Ries J, Yu SR, Burkhardt M, Brand M, Schwille P 2009a. Modular scanning FCS quantifies receptor-ligand interactions in living multicellular organisms. Nat Methods 6: U643–U631 [DOI] [PubMed] [Google Scholar]
  175. Rigler R, Mets U, Widengren J, Kask P 1993. Fluorescence correlation spectroscopy with high count rate and low-background—Analysis of translational diffusion. Euro Biophys J Biophys Lett 22: 169–175 [Google Scholar]
  176. Rotblat B, Prior IA, Muncke C, Parton RG, Kloog Y, Henis YI, Hancock JF 2004. Three separable domains regulate GTP-dependent association of H-ras with the plasma membrane. Mol Cell Biol 24: 6799–6810 [DOI] [PMC free article] [PubMed] [Google Scholar]
  177. Roy S, Plowman S, Rotblat B, Prior IA, Muncke C, Grainger S, Parton RG, Henis YI, Kloog Y, Hancock JF 2005. Individual palmitoyl residues serve distinct roles in H-ras trafficking, microlocalization, and signaling. Mol Cell Biol 25: 6722–6733 [DOI] [PMC free article] [PubMed] [Google Scholar]
  178. Runnels LW, Scarlata SF 1995. Theory and application of fluorescence homotransfer to melittin oligomerization. Biophys J 69: 1569–1583 [DOI] [PMC free article] [PubMed] [Google Scholar]
  179. Rusinova E, Tretyachenko-Ladokhina V, Vele OE, Senear DF, Ross JBA 2002. Alexa and Oregon Green dyes as fluorescence anisotropy probes for measuring protein–protein and protein–nucleic acid interactions. Anal Biochem 308: 18–25 [DOI] [PubMed] [Google Scholar]
  180. Sahoo H, Roccatano D, Hennig A, Nau WM 2007. A 10-angstrom spectroscopic ruler applied to short polyprolines. J Am Chem Soc 129: 9762–9772 [DOI] [PubMed] [Google Scholar]
  181. Sako Y, Minoghchi S, Yanagida T 2000. Single-molecule imaging of EGFR signalling on the surface of living cells. Nat Cell Biol 2: 168–172 [DOI] [PubMed] [Google Scholar]
  182. Saxton MJ 1994a. Anomalous diffusion due to obstacles—A Monte Carlo study. Biophys J 66: 394–401 [DOI] [PMC free article] [PubMed] [Google Scholar]
  183. Saxton MJ 1994b. Single-particle tracking—Models of directed transport. Biophys J 67: 2110–2119 [DOI] [PMC free article] [PubMed] [Google Scholar]
  184. Saxton MJ 1995. Single-tracking-effects of corrals. Biophys J 69: 389–398 [DOI] [PMC free article] [PubMed] [Google Scholar]
  185. Saxton MJ 1996a. Anomalous diffusion due to binding: A Monte Carlo study, Biophys J 70: 1250–1262 [DOI] [PMC free article] [PubMed] [Google Scholar]
  186. Saxton MJ 1996b. Single-particle tracking: New methods of data analysis, Biophys J 70: TU415–TU415 [Google Scholar]
  187. Saxton MJ 1997. Single-particle tracking: The distribution of diffusion coefficients. Biophys J 72: 1744–1753 [DOI] [PMC free article] [PubMed] [Google Scholar]
  188. Saxton MJ, Jacobson K 1997. Single-particle tracking: Applications to membrane dynamics. Annu Rev Biophys Biomol Struct 26: 373–399 [DOI] [PubMed] [Google Scholar]
  189. Scherfeld D, Kahya N, Schwille P 2003. Lipid dynamics and domain formation in model membranes composed of ternary mixtures of unsaturated and saturated phosphatidylcholines and cholesterol. Biophys J 85: 3758–3768 [DOI] [PMC free article] [PubMed] [Google Scholar]
  190. Schnapp BJ, Gelles J, Sheetz MP 1988. Nanometer-scale measurements using video light-microscopy. Cell Motility Cytoskeleton 10: 47–53 [DOI] [PubMed] [Google Scholar]
  191. Schultz C, Neef AB, Gadella TW Jr, Goedhart J 2010. Imaging lipids in living cells. Cold Spring Harb Protoc [DOI] [PubMed] [Google Scholar]
  192. Schutz GJ, Schindler H, Schmidt T 1997. Single-molecule microscopy on model membranes reveals anomalous diffusion. Biophys J 73: 1073–1080 [DOI] [PMC free article] [PubMed] [Google Scholar]
  193. Schutz GJ, Kada G, Pastushenko VP, Schindler H 2000. Properties of lipid microdomains in a muscle cell membrane visualized by single molecule microscopy. EMBO J 19: 892–901 [DOI] [PMC free article] [PubMed] [Google Scholar]
  194. Schwarzenbacher M, Kaltenbrunner M, Brameshuber M, Hesch C, Paster W, Weghuber J, Heise B, Sonnleitner A, Stockinger H, Schutz GJ 2008. Micropatterning for quantitative analysis of protein–protein interactions in living cells. Nat Methods 5: 1053–1060 [DOI] [PubMed] [Google Scholar]
  195. Schwille P 2003. TIR-FCS: Staying on the surface can sometimes be better. Biophys J 85: 2783–2784 [DOI] [PMC free article] [PubMed] [Google Scholar]
  196. Schwille P, Heinze KG 2001. Two-photon fluorescence cross-correlation spectroscopy. Chemphyschem 2: 269–272 [DOI] [PubMed] [Google Scholar]
  197. Schwille P, Korlach J, Webb WW 1999a. Fluorescence correlation spectroscopy with single-molecule sensitivity on cell and model membranes. Cytometry 36: 176–182 [DOI] [PubMed] [Google Scholar]
  198. Schwille P, MeyerAlmes FJ, Rigler R 1997. Dual-color fluorescence cross-correlation spectroscopy for multicomponent diffusional analysis in solution. Biophys J 72: 1878–1886 [DOI] [PMC free article] [PubMed] [Google Scholar]
  199. Schwille P, Haupts U, Maiti S, Webb WW 1999b. Molecular dynamics in living cells observed by fluorescence correlation spectroscopy with one- and two-photon excitation. Biophys J 77: 2251–2265 [DOI] [PMC free article] [PubMed] [Google Scholar]
  200. Schwille P, Heinze K, Dittrich P, Haustein E 2009. Two-photon fluorescence correlation spectroscopy. In Biomedical optical imaging (ed. Fujimoto JG, Farkas D). Oxford University Press, Oxford [Google Scholar]
  201. Sharma P, Varma R, Sarasij RC, Ira K, Gousset G, Krishnamoorthy M, Rao S, Mayor S 2004. Nanoscale organization of multiple GPI-anchored proteins in living cell membranes. Cell 116: 577–589 [DOI] [PubMed] [Google Scholar]
  202. Sheetz MP, Kuo SC 1993. Tracking nanometer movements of single motor molecules. Meth Cell Biol 39: 129–136 [DOI] [PubMed] [Google Scholar]
  203. Sheppard CJR, Wilson T 1979. Effect of spherical-aberration on the imaging properties of scanning optical microscopes. Appl Opt 18: 1058–1063 [DOI] [PubMed] [Google Scholar]
  204. Shvartsman DE, Gutman O, Tietz A, Henis 2006. Cyclodextrins but not compactin inhibit the lateral diffusion of membrane proteins independent of cholesterol. Traffic 7: 917–926 [DOI] [PubMed] [Google Scholar]
  205. Snapp EL, Altan N, Lippincott-Schwartz J 2003. Measuring protein mobility by photobleaching GFP chimeras in living cells. Curr Protoc Cell Biol 21: 2121. [DOI] [PubMed] [Google Scholar]
  206. Sohn HW, Tolar P, Brzostowski J, Pierce SK 2010. A method for analyzing protein–protein interactions in the plasma membrane of live B cells by fluorescence resonance energy transfer imaging as acquired by total internal reflection fluorescence microscopy. Methods Mol Biol 591: 159–183 [DOI] [PMC free article] [PubMed] [Google Scholar]
  207. Soumpasis DM 1983. Theoretical analysis of fluorescence photobleaching recovery experiments. Biophysical J 41: 95–97 [DOI] [PMC free article] [PubMed] [Google Scholar]
  208. Spandl J, White DJ, Peychl J, Thiele C 2009. Live cell multicolor imaging of lipid droplets with a new dye, LD540. Traffic 10: 1579–1584 [DOI] [PubMed] [Google Scholar]
  209. Sprague BL, Pego RL, Stavreva DA, McNally JG 2004. Analysis of binding reactions by fluorescence recovery after photobleaching. Biophys J 86: 3473–3495 [DOI] [PMC free article] [PubMed] [Google Scholar]
  210. Sprague BL, McNally JG 2005. FRAP analysis of binding: Proper and fitting. Trends in Cell Biol 15: 84–91 [DOI] [PubMed] [Google Scholar]
  211. Sum AK, Faller R, de Pablo JJ 2003. Molecular simulation study of phospholipid bilayers and insights of the interactions with disaccharides. Biophys J 85: 2830–2844 [DOI] [PMC free article] [PubMed] [Google Scholar]
  212. Teramura Y, Ichinose J, Takagi H, Nishida K, Yanagida T, Sako Y 2006. Single-molecule analysis of epidermal growth factor binding on the surface of living cells. EMBO J 25: 4215–4222 [DOI] [PMC free article] [PubMed] [Google Scholar]
  213. Thiele C, Spandl J 2008. Cell biology of lipid droplets. Curr Opin Cell Biol 20: 378–385 [DOI] [PubMed] [Google Scholar]
  214. Tomishige M, Sako Y, Kusumi A 1998. Regulation mechanism of the lateral diffusion of band 3 in erythrocyte membranes by the membrane skeleton. J Cell Biol 142: 989–1000 [DOI] [PMC free article] [PubMed] [Google Scholar]
  215. Toprak E, Balci H, Blehm BH, Selvin PR 2007. Three-dimensional particle tracking via bifocal imaging. Nano Lett 7: 2043–2045 [DOI] [PubMed] [Google Scholar]
  216. Tyteca D, D’Auria L, Van Der Smissen P, Medts T, Carpentier S, Monbaliu JC, de Diesbach P, Courtoy PJ 2010. Three unrelated sphingomyelin analogs spontaneously cluster into plasma membrane micrometric domains. Biochim Biophys Acta 1798: 909–927 [DOI] [PubMed] [Google Scholar]
  217. Vacha R, Siu SWI, Petrov M, Bockmann RA, Barucha-Kraszewska J, Jurkiewicz P, Hof M, Berkowitz ML, Jungwirth P 2009. Effects of alkali cations and halide anions on the DOPC lipid membrane. J Phys Chem A 113: 7235–7243 [DOI] [PubMed] [Google Scholar]
  218. van den Bogaart G, Hermans N, Krasnikov V, de Vries AH, Poolman B 2007. On the decrease in lateral mobility of phospholipids by sugars. Biophys J 92: 1598–1605 [DOI] [PMC free article] [PubMed] [Google Scholar]
  219. Varma R, Mayor S 1998. GPI-anchored proteins are organized in submicron domains at the cell surface. Nature 394: 798–801 [DOI] [PubMed] [Google Scholar]
  220. Veatch SL, Keller SL 2002. Organization in lipid membranes containing cholesterol. Phys Rev Lett 89: 268101–268104 [DOI] [PubMed] [Google Scholar]
  221. Veatch SL, Keller SL 2003. Separation of liquid phases in giant vesicles of ternary mixtures of phospholipids and cholesterol. Biophys J 85: 3074–3083 [DOI] [PMC free article] [PubMed] [Google Scholar]
  222. Wallrabe H, Stanley M, Periasamy A, Barroso M 2003. One- and two-photon fluorescence resonance energy transfer microscopy to establish a clustered distribution of receptor-ligand complexes in endocytic membranes. J Biomed Opt 8: 339–346 [DOI] [PubMed] [Google Scholar]
  223. Wawrezinieck L, Rigneault H, Marguet D, Lenne PF 2005. Fluorescence correlation spectroscopy diffusion laws to probe the submicron cell membrane organization. Biophys J 89: 4029–4042 [DOI] [PMC free article] [PubMed] [Google Scholar]
  224. Weidemann T, Wachsmuth M, Tewes M, Rippe K, Langowski J 2002. Analysis of ligand binding by two-colour fluorescence cross-correlation spectroscopy. Single Mol 3: 49–61 [Google Scholar]
  225. Weiss M 2004. Challenges and artifacts in quantitative photobleaching experiments. Traffic 5: 662–671 [DOI] [PubMed] [Google Scholar]
  226. Wenger J, Conchonaud F, Dintinger J, Wawrezinieck L, Ebbesen TW, Rigneault H, Marguet D, Lenne PF 2007. Diffusion analysis within single nanometric apertures reveals the ultrafine cell membrane organization. Biophys J 92: 913–919 [DOI] [PMC free article] [PubMed] [Google Scholar]
  227. Wolf DE 1989. Designing, building, and using a fluorescence recovery after photobleaching instrument. In Methods in cell biology (ed. Taylor DL, Wang Y-L), pp. 271–332 Academic Press, New York; [DOI] [PubMed] [Google Scholar]
  228. Worch R, Bokel C, Hofinger S, Schwille P, Weidemann T 2010. Focus on composition and interaction potential of single-pass transmembrane domains. Proteomics 10: 4196–4208 [DOI] [PubMed] [Google Scholar]
  229. Wouters FS, Bastiaens PIH, Wirtz KWA, Jovin TM 1998. FRET microscopy demonstrates molecular association of non-specific lipid transfer protein (nsL-TP) with fatty acid oxidation enzymes in peroxisomes. EMBO J 17: 7179–7189 [DOI] [PMC free article] [PubMed] [Google Scholar]
  230. Yildiz A, Forkey JN, McKinney SA, Ha T, Goldman YE, Selvin PR 2003. Myosin V walks hand-over-hand: Single fluorophore imaging with 1.5-nm localization. Science 300: 2061–2065 [DOI] [PubMed] [Google Scholar]
  231. Yildiz A, Park H, Safer D, Yang ZH, Chen LQ, Selvin PR, Sweeney HL 2004a. Myosin VI steps via a hand-over-hand mechanism with its lever arm undergoing fluctuations when attached to actin. J Biol Chem 279: 37223–37226 [DOI] [PubMed] [Google Scholar]
  232. Yildiz A, Tomishige M, Vale RD, Selvin PR 2004b. Kinesin walks hand-over-hand. Science 303: 676–678 [DOI] [PubMed] [Google Scholar]
  233. Yu CX, Hale J, Ritchie K, Prasad NK, Irudayaraj J 2009. Receptor overexpression or inhibition alters cell surface dynamics of EGF-EGFR interaction: New insights from real-time single molecule analysis. Biochem Biophys Res Commun 378: 376–382 [DOI] [PubMed] [Google Scholar]
  234. Yu SR, Burkhardt M, Nowak M, Ries J, Petrasek Z, Scholpp S, Schwille P, Brand M 2009. Fgf8 morphogen gradient forms by a source-sink mechanism with freely diffusing molecules. Nature 461: U533–U100 [DOI] [PubMed] [Google Scholar]

Articles from Cold Spring Harbor Perspectives in Biology are provided here courtesy of Cold Spring Harbor Laboratory Press

RESOURCES