Skip to main content
Frontiers in Sports and Active Living logoLink to Frontiers in Sports and Active Living
. 2026 Sep 4;8:1908480. doi: 10.3389/fspor.2026.1908480

Effect of various carbon plate running shoes on peak tibial accelerations, lateral asymmetry and residual shock in running

Marlene Riedl 1,2, René Schwesig 1, Olaf Ueberschär 2,3,*
PMCID: PMC13585708  PMID: 42761138

Abstract

Carbon plate running shoes (CPRS) have significantly advanced running shoe technology, but their orthopaedic impact remains controversial. Remarkably, most running-related overuse injuries affect one leg only, although running is generally considered a symmetrical physical activity. Therefore, this study examined whether CPRS affect biomechanical loading and between-leg symmetry. Twenty-two trained amateur triathletes (13 men and 9 women) participated in a two-day trial. On day 1, ventilatory thresholds (VT1 and VT2) were determined through incremental treadmill testing. On day 2, participants completed five 3-min running trials at three different speeds [90% vVT1, 0.5(vVT1 + vVT2), and 100% vVT2] while wearing four different CPRS models, and their own non-CPRS. Inertial measurement units recorded time-continuous tri-axial tibial accelerations. Results show that peak tibial accelerations and, in parts, also residual shock varied across CPRS models (p < 0.021), but lateral asymmetry remained unchanged (p > 0.361). Interestingly, the findings varied between sexes and exhibited substantial inter-individual effects. These results suggest that increased injury rates possibly associated with CPRS might not be due to altered between-leg asymmetry, but perhaps because of other factors involving residual shock and/or tibial loading patterns during stance phase. Future research should explore these effects across a broader range of CPRS models.

Keywords: advanced footwear technology, asymmetry index, biomechanics, inertial measure unit, running gait

1. Introduction

Since its introduction in 2017 (1, 2), Advanced Footwear Technology (AFT) has become one of the most impactful improvements in running equipment technology, alongside running watches (3, 4). Several new world records have been set, and many amateur runners have started using AFT in their races and training. While many studies have shown that AFT improves running economy (2, 5–7), their biomechanical effects seem to be double-edged, and the underlying biomechanical effects and their orthopaedic implications are a subject of ongoing scientific debate (4, 8, 9).

The prevalence of running-induced overuse injuries, particularly to the Achilles tendon, has been reported to be increasing (10). However, most injury reports related to AFT continue to be constituted by case reports (11). Such injuries generally arise from the repetitive loading of the musculoskeletal system with each stride while there is a mismatch of loading and load-bearing capacity of the involved tissues (12). Despite the high level of cushioning provided by AFT, the biomechanical loads on the lower extremity are not necessarily reduced. In fact, studies have shown that highly cushioned shoes may in fact lead to an increase in impact peaks of ground reaction force (GRF) and loading rates (12). This contradicts the commonly held belief that higher cushioning should result in lower impact forces. Recent research shows that a high midsole stack height may alter peak tibial accelerations (PTAs) (13). In this light, the present study aims to investigate the extent to which different AFT models modify the amplitude of PTA, which form a well-established surrogate measure for external loading and are related to GRF metrics (14–18). It should be noted that PTAs per se may not adequately represent internal bone forces because of substantial internal muscle forces, but they are capable of providing a valid quantitative picture of external dynamics in running, and may potentially be used to elucidate internal loading through specific machine learning approaches (19, 20). Given the focus of this study on the use of carbon plate running shoes (CPRS), this term is employed in the following with preference to the more general AFT for the sake of clarity.

From an orthopaedic perspective, it should be noted that running-induced overuse injuries typically affect only one of the two legs, despite the fact that running is generally considered to be a per se symmetrical sport. It may thus be hypothesised that musculoskeletal or habitual asymmetries have a role to play in the aetiopathogenesis of such injuries. In general terms, asymmetry defined as a functional or morphological difference between the two sides of the body, or two limbs in particular (21). Specifically to bipedal running, kinematic and related kinetic differences between the two legs may manifest themselves as lateral asymmetries, which can be detected by a disparity between the PTAs of the left and the right leg for each step (18, 22). Researchers have examined alterations in this naturally occurring lateral asymmetry in terms of PTA across various surfaces, including concrete, grass, and tartan (18), as well as distinct training sessions (23). Additionally, investigations have been conducted on athletes following injury to ascertain the underlying causes of such occurrences (24). However, the question how kinematic asymmetries, as measurable through PTA, may be altered by CPRS has not been elucidated so far. Therefore, the present study aims to bridge this research gap by investigating how CPRS interact with existing lateral asymmetries in running. Theoretically, both amplification or mitigation, or even their initial introduction would be conceivable effects.

Moreover, this study investigates residual shock as the third biomechanical parameter accessible through peak accelerations. Residual shock is defined as the proportion of tibial acceleration shock that is transmitted to the pelvis, and its quantification has the potential to provide valuable insights into musculoskeletal factors such as limb stiffness, core stability, neuromuscular status of fatigue, or biomechanical running efficiency. Therefore, residual shock has been discussed in the literature as a potentially contributing factor to sustaining running-induced overuse injuries (18, 25, 26). In view of the possible effects of CPRS on PTA, we hypothesise that residual shock may be subject to an alteration by CPRS.

Altogether, this study investigates how CPRS affect PTA amplitudes, their lateral asymmetries and the residual shock at the pelvis, and discusses the findings in the framework of possible biomechanical rationales.

2. Methods

2.1. Subjects

Following the statistical power analysis put forward by Xiang et al. (2022) for a related research question (13), we set the expected effect size to 0.25 and the statistical power to 0.8. With α = 0.05 and β = 0.2, a minimum of 21 participants was required for this study. To this end, we recruited 22 amateur runners and triathletes, of whom 13 were males (35.0 ± 8.0 years, 71.9 ± 8.6 kg, BMI 22.7 ± 2.0 kg m−2, V˙O2peak 61.6 ± 5.1 ml kg−1 min−1) and nine females (29.2 ± 10.3 years, 61.3 ± 5.7 kg, BMI 21.5 ± 1.3 kg m−2, V˙O2peak 52.7 ± 3.1 mL kg−1 min−1). All athletes had a personal best over 10 km road running of better than 45 min (males, actual sub-cohort mean of 37:00 ± 2:54 min) or better than 50 min (females, 44:06 ± 3:42 min), respectively, and reported an individual average weekly running mileage of at least 20 km (33.3 ± 12.0 km). All runners declared to have been free of injuries for at least three months prior to their participation in the study, and confirmed to be in good health at the days of testing. The study was conducted in accordance with the most recent revision of the Declaration of Helsinki (27), and was approved by the Ethics Committee of the Magdeburg-Stendal University of Applied Sciences (EKIWID-2023-09-001RM). All subjects provided written informed consent prior to their participation.

2.2. Footwear conditions

Four CPRS from four different manufacturers were included in this study (Figures 1d–g): Hoka Rocket X2 (HOK), Mizuno Wave Rebellion Pro (MIZ), Puma Fast-R Nitro Elite (PUM), and Saucony Endorphin Pro 3 (SAU) (7). Basic structural properties are summarised in Table 1 for the average size of the cohort's males and females. Shoe sizes of the participants ranged from US 7 to US 11.5 for the men, and from US 7 to US 10.5 for the women. The participant's individual own pair of training shoes (OWN) served as an individual reference to the specific asymmetry inherent to each athlete at a given running speed (23). The ranges of basic structural properties for OWN are given in Table 1, with more detailed information on each shoe worn by participants provided in the Supplementary Table 1. Despite the variety in individual OWN models, they essentially meet the recommendations on neutrality and wide availability of simple footwear technology for control study purposes as proposed by Burns et al. (4). More generally, switching from OWN to a current CPRS model pictures a realistic scenario for amateur athletes when changing from non-carbon plate to carbon plate running shoes for competitions.

Figure 1.

Panel A displays two ankles wearing white running shoes with black straps and small orange devices attached. Panel B shows a person placing or adjusting an orange device on an ankle strap. Panel C reveals an orange device positioned inside the waistband of black athletic clothing. Panels D, E, F, and G each present a single running shoe from different brands and color schemes, shown in profile against a white background.

Sensor placement and CPRS footwear conditions. (A-C) Placement of the three IMUs at the distal tibiae, and lumbo-sacral region with tightly fitted Velcro straps. (D–G) The four used CPRS in this study. Reprinted from Riedl et al. (7), licensed under CC-BY. (D) Hoka Rocket X2 (HOK), (E) Mizuno Wave Rebellion Pro (MIZ), (F) Puma Fast-R Nitro Elite (PUM), and (G) Saucony Endorphin Pro 3 (SAU).

Table 1.

Basic structural properties of the four CPRS and the OWN models used.

Property HOK MIZ PUM SAU OWN
Hoka Rocket X2 Mizuno Wave Rebellion Pro Puma Fast-R Nitro Elite Saucony Endorphin Pro 3
Release year1 2023 2023 2022 2022 2019–2022
Mass (men US 9.5)* 219 g 218 g 231 g 210 g 220–335 g
Mass (women US 8.5)* 200 g 192 g 202 g 186 g 188–266 g
Heel drop1 5.0 mm 4.5 mm 7.5 mm 8.0 mm 4.0–10.0 mm
Midsole foam1 PEBA foam ‘Mizuno Enerzy Lite/Lite+’ the latter being PEBA foam forefoot PEBA foam, heel EVA foam ‘PWRRUNPB’ PEBA foam
Carbon plate1 Carbon plate between two layers of foam Carbon-infused nylon plate (70% nylon, 30% carbon) Carbon plate named ‘PWRPLATE’ S-shaped carbon plate
Upper material1 Synthetic mesh Knitted polyester from elastic thread Transparent monomesh Thin, breathable mesh

* measured in our laboratory; 1 data taken from Ref. (28) for HOK, from Ref (29, 30). for MIZ, from Ref (31). for PUM, and from Ref (32). for SAU. The masses shown for OWN represent the average masses as weighed for the cohort of test subjects.

2.3. Inertial measurement units (IMUs)

Inertial measurement units (IMUs) of the type Xsens MTw Awinda (Movella Technologies B.V., Enschede, The Netherlands), which have been extensively validated and used in previous research in sports science and biomechanics (18, 24, 33–37) were used. These IMUs permit the non-invasive measurements of time-continuous tri-axial accelerations, angular velocity and magnetic field strength. Their small dimensions (4.7 cm × 3.0 cm × 1.3 cm) and minimal weight (16 g) ensure that they do not distract or interfere with the athletes during the tests. The internal sampling rate of 1000 Hz was downsampled through strapdown integration and sensor fusion to an effective, time-continuous output data rate of 120 Hz, following previous studies (18, 23, 33). Noteworthily, the manufacturer's sensor fusion algorithms preserve actual peak amplitudes and positions despite reduced temporal resolution (18, 38, 39). The axial measurement range is ±16 g with 1 g ≈ 9.81 m s−2, which has been widely shown to suffice for the intended study design (15, 17, 18). Gravity was not removed to ensure that the total acting acceleration was analysed, including both the (dominant) inertial and the gravitational contribution. In this study three IMUs of the described type were fixed noninvasively to three different body segments using tightly fitting VelcroTM straps: Two sensors were positioned on the distal anteromedial sections of the right and left tibia (with the lower edge of the IMU housing being placed 7 cm above the top of the medial malleolus, Figures 1a,b) and on the lumbo-sacral region near L5/S1 (Figure 1c), in line with the placement in previous research (18, 23). By applying these sensor positions, relative soft tissue motion between the IMUs and the bones is minimised (17, 18).

2.4. Study design

This study was conducted applying a two-day trial design. On day 1, the initial assessment, the subjects completed a standardised incremental test protocol on a motorised treadmill (Star Trac FreeRunner 10TRx, Core Health 6 Fitness, Vancouver, BC, Canada), set at 1% incline (40), until voluntary exhaustion. In this incremental test, the participants wore their own preferred pair of (non-carbon plate) running shoes with which they would self-reportedly run a race if no CPRS were available. Starting at 6 km h−1, the speed was increased in steps of 2 km h−1 every 3 min. The first two stages (i.e., at speeds of 6 and 8 km h−1, respectively) were used as a standardised warm-up. During the entire test, the heart rate was monitored using a chest strap monitor (Polar H10; Polar Electro Oy, Kempele, Finland), and continuous breath-by-breath cardiopulmonary gas exchange data were collected (MetaMax 3B, CORTEX Biophysik GmbH, Leipzig, Germany).

Based on the results of these tests, the individual running speeds at ventilatory thresholds 1 (vVT1) and 2 (vVT2) were derived. If a ventilatory threshold was found within a stage, threshold speed was corrected by linear interpolation between the running speeds of the adjacent stages. Using the experimental values for vVT1 and vVT2, three individual running speeds (v1, v2 and v3) were calculated for the second test on day 2:

v1=90%vVT1,v2=0.5(vVT1+vVT2)andv3=100%vVT2 (1)

These speeds were chosen to cover the full spectrum of running speeds that runners typically use in their training and racing, ranging from easy to moderate zone 2 training, via intense zone 3 training, to transition zone 3/ zone 4 racing speed near maximum lactate steady state (41).

On day 2, which took place at least 48 hours after the first day, the same experimental setup was utilised as described for the initial incremental test. This time, however, the athletes performed 5 sessions of 3 × 3 min of treadmill running each, wearing one out of five different pair of shoes in each session in a randomised order (4 CPRS, OWN). The randomisation process was conducted utilising Office 365 Excel (Microsoft Corporation, WA, USA) through the formula input

=SORTBY(A1:A5;RANDARRAY(5)) (2)

employed for each participant, where the cells A1–A5 contain the codes for HOK, MIZ, PUM, SAU, and OWN.

The sessions were run at increasing speeds v1, v2 and v3 in fixed order, resulting in 9 consecutive minutes of running. After each session, a five-minute break was allotted for the athletes to change footwear and achieve a physiological state as close to baseline as possible given the trade-off between practicability and comparability of results. The fixed order of the speeds was chosen so that there was an increasing effort for each specific shoe, and because running at v1 provided an additional means of active recovery after a previous intense v3 run. Despite expected to be small, a residual effect of a previous v3 run on the subsequent v1 run could not be fully ruled out. Notwithstanding, the randomisation of shoe order among subjects is believed to minimise any relatable effect in this regard.

2.5. Data analysis

The initial processing of the raw acceleration data was conducted using a proprietary software (MT Software Suite MTwTM AwindaTM 4.8, Xsens Technologies B.V., Enschede, Netherlands). This software converted the binary data into text format. Subsequent data processing and analysis were performed using a custom software program employing local peak detection in time-continuous acceleration data with self-adjusting thresholds and noise filtering [written in LabVIEW 2023 Q3 (National Instruments, Austin, TX, USA)]. Specifically, the vector magnitudes of triaxial tibial accelerations were calculated using the standard Euclidean norm, i.e.

|a→(t)|=ax(t)2+ay(t)2+az(t)2, (3)

where ax, ay and az denote the Cartesian vector components in the local reference frame of the IMU sensor. Based on these magnitude time series, a total of 2.5 min of data was extracted from each three-minute segment, with the initial and final 15 seconds excluded from the analysis (i.e., seconds 15–165) to account for any potential accommodation or cessation effects. Using the built-in peak detection procedure of LabVIEW [Peak Detector.VI (42)], peaks were identified in the time series by fitting quadratic polynomials to three sequential data points of the unfiltered raw data (33, 43). The threshold of minimal peak amplitudes was set to 4 g, reflecting the observation in our study that at speeds at or beyond v1, each athlete's impact peaks of each step exceeded at that threshold. The minimum temporal distance between two neighbouring peaks was to set to 50% of the median detected stride duration, thereby minimising the risk of falsely detecting double peaks. In addition, the results for each segment automatically analysed were checked visually, and any incorrectly identified single steps were excluded manually. The median values of the detected peak tibial accelerations (PTA) for the left leg (aleft) and right leg (aright) were then used to calculate the lateral asymmetry index LTA3D) as defined by

LTA3D:=aleft−aright12(aleft+aright). (4)

Notably, median values were used instead of arithmetic means to minimise any potential bias by outliers, while the computation on leg-wise medians was given preference to a step-wise evaluation of Equation (4) to further improve the signal-to-noise ratio. On the level of individual athletes, signed values of LTA3D, as defined by Equation (4), were employed for any further exploratory analyses, meaning that both positive (or zero, i.e., non-negative) and negative values may occur.

On the cohort level, however, absolute values of asymmetry indexes aLTA3D defined by

aLTA3D:=|LTA3D|≥0 (5)

were used for subsequent statistical analyses to avoid numerical cancelling effects of positive and negative values.

In analogy to PTA, peak sacral accelerations (PSA) were detected for each step based on the time series of triaxial acceleration magnitudes obtained from the IMU worn at the sacrum, and their median values were used for further statistical analysis. Residual shock (RSh) in the time domain, reflecting the transmission of the impact shock wave from the tibiae to the pelvis (18), was then calculated using the ratio of median PSA and median PTA amplitudes (44–47), i.e.

RSh:=PSAPTA, (6)

with PTA denoting the mean of left and right PTA, i.e., PTA:=12(aleft+aright).

In order to determine the dominant leg, the athletes were asked to report their habitually preferred jumping and stance leg if applicable. For further statistical analysis, the product P of LTA3D and the leg dominance index κ was calculated separately for jumping and stance leg as the product

P:=LTA3D⋅κ, (7)

where κ was defined as

κ:={+1ifleftlegisdominant-1ifrightlegisdominant0otherwise(i.e.,indifferentlegdominance). (8)

The rationale behind this definition is as follows: If leg dominance and lateral asymmetry in terms of PTA were stochastically independent, P and LTA3D should exhibit the same statistical distribution because no significant shifts in the distribution of positive and negative signs should occur between LTA3D and P. That is, runners with a left-dominant lateral asymmetry (i.e., LTA3D > 0) would exhibit both left-leg and right-leg habitual preference across the cohort. In other words, LTA3D and P would be subject to the same (quasi-random) statistical distribution. If, however, a left-dominant lateral asymmetry (LTA3D > 0) were associated with a habitual preference of the left leg (κ=1), and, therefore, right-leg PTA dominance (LTA3D < 0) were linked to habitual right-leg preference (κ=−1), the product P=LTA3D⋅κ≥0 would be non-negative, thus clearly needing to show a different distribution of values compared to LTA3D><0.)

2.6. Statistical analysis

All statistical tests were performed using IBM SPSS Statistics (Version 29, Armonk, NY, USA). The significance level was set to p < α = 0.05 for all statistical tests. If not stated otherwise, all average values are given as mean ± standard deviation. The Shapiro–Wilk test was employed to check normality of the data, whilst the Mauchly test was utilised to determine the sphericity of the data.

For normally distributed data, the subsequent inferential statistical analysis was conducted using a three-way mixed-model analysis of variance (mixed ANOVA) with footwear condition (FWC) and running speed as within-subject factors, and sex as the between-subject factor. It was used to investigate the effects of FWC, running speed, sex, and their interactions on triaxial PTA (18). Post-hoc pairwise comparisons with Bonferroni correction were performed when mixed ANOVA yielded significant results. Partial eta squared (ηp2) was calculated to estimate the effect size of the main effects, and interpreted according to Cohen (48, 49): Small effects for ηp2 > 0.01, medium effects for ηp2 > 0.06, large effects for ηp2 > 0.14. In addition, the effect sizes of the post-hoc comparison were estimated by virtue of Cohen's d (dCohen), with dCohen ≥ 0.2 representing a small effect, dCohen ≥ 0.5 a medium effect, and dCohen ≥ 0.8 a large effect (50, 51). For data that were not normally distributed, the aligned rank transform was conducted using the software ARTool (Version 2.2.2) (52). Subsequent analysis was conducted using a mixed ANOVA for each aligned rank condition separately (FWC, speed, FWC*speed). The objective was to investigate the effects of FWC, running speed, sex, and their interactions on RSh and LTA3D. For significant results, post-hoc pairwise comparisons were performed through Wilcoxon signed-rank test with Bonferroni correction. The estimation of effect sizes was then conducted by r=|Z|/n, with r < 0.1 representing a negligible effect, 0.1 ≤ r < 0.3 a small effect, 0.3 ≤ r < 0.5 a medium effect, and r ≥ 0.5 a large effect. For the analysis of the influence of the dominant leg on LTA3D, a χ2 test was employed to test whether the distributions of LTA3D and P were statistically equivalent, or, otherwise, if P was shifted towards non-negative values [cf. Equation (7)].

3. Results

The average speeds at which the ventilatory thresholds of the athletes were reached were vVT1 = 11.4 ± 1.1 km h−1 and vVT2 = 15.5 ± 1.6 km h−1, corresponding to average testing speeds of v1 = 10.3 ± 1.0 km h−1, v2 = 13.5 ± 1.3 km h−1 and v3 = 15.5 ± 1.6 km h−1. Group-level speeds for male and female athletes are displayed in Table 2.

Table 2.

Running speeds at ventilatory thresholds 1 & 2 (vVT1 & vVT2) and speeds for the CPRS test (v1, v2 & v3) for all athletes as well as females only and males only.

Sub-cohort Speed [km h−1]
vVT1 ± σ vVT2 ± σ v1 ± σ v2 ± σ v3 ± σ
All athletes 11.4 ± 1.1 15.5 ± 1.6 10.3 ± 1.0 13.5 ± 1.3 15.5 ± 1.6
Female 10.7 ± 0.7 14.2 ± 0.7 9.6 ± 0.6 12.5 ± 0.7 14.2 ± 0.7
Male 11.9 ± 1.0 16.4 ± 1.4 10.7 ± 0.9 14.2 ± 1.2 16.4 ± 1.4

σ, standard deviation, vVT1 & vVT2, speed at ventilatory threshold 1 & 2, v1, v2 & v3, speed for the CPRS test, calculation described in methods.

3.1. Triaxial peak tibial acceleration

As illustrated in Figure 2, mean triaxial PTA increases with speed for the 5 FWCs. The mixed-model three-way ANOVA (Table 3) revealed large effects of FWC (p < 0.001, ηp2 = 0.44) and running speed (p < 0.001, ηp2 = 0.893) on PTA. It also showed significant interactions between FWC and sex (p = 0.008, ηp2 = 0.157), and between speed and sex (p = 0.022, ηp2 = 0.217). Given these significant interactions, the main effects for FWC and running speed were not analysed further.

Figure 2.

Box plot graphic comparing triaxial peak tibial acceleration in g across three velocities (v1, v2, v3) for five footwear types (HOK, MIZ, PUM, SAU, OWN). Individual subject data points are color-coded and connected with lines. Median, mean, interquartile range, and whiskers are illustrated, showing an increase in peak tibial acceleration with higher velocities across all footwear categories.

Distribution of triaxial peak tibial acceleration across five footwear conditions at the three running speeds v1, v2, and v3. Boxplots summarise the data (median, IQR, and 1.5 × IQR whiskers), while observations for individual participants are shown as dots connected by lines to illustrate within-subject changes across footwear conditions at each running speed. Footwear conditions: HOK (Hoka Rocket X2), MIZ (Mizuno Wave Rebellion Pro), PUM (Puma Fast-R Nitro Elite), SAU (Saucony Endorphin Pro 3) and OWN (own pair of non-carbon plate running shoes).

Table 3.

Results of mixed-model three-way ANOVA on PTA.

Effect p η p 2 df F Sphericity correction
FWC <0.001 * 0.440 4 15.721 Not required
FWC*Gender 0.008 * 0.157 4 3.715 Not required
Speed <0.001 * 0.893 1.186 167.552 Greenhouse-Geisser
Speed*Gender 0.022 * 0.217 1.186 5.559 Greenhouse-Geisser
FWC*Speed 0.053 0.124 2.669 2.824 Greenhouse-Geisser
FWC*Speed*Gender 0.288 0.060 2.669 1.287 Greenhouse-Geisser

*, Statistically significant (p < 0.05), ηp2, partial eta-squared, df, degrees of freedom, F, F-statistics.

Instead, when comparing both sexes, a significant difference was found between the group of male and female athletes for the FWC OWN (p = 0.015) with a small effect size (dCohen = 0.26). The CPRS FWC conditions, in turn, did not show significant differences between the sexes. When comparing the different FWC at the group level, the effect of FWC differed between males and females: In the females, significant differences in FWC were found for HOK vs. MIZ (p = 0.028), HOK vs. PUM (p = 0.008), HOK vs. OWN (p < 0.001), and SAU vs. OWN (p = 0.003). However, most effects were negligible (HOK vs. PUM: dCohen = 0.068; HOK vs. OWN: dCohen = 0.034; SAU vs. OWN: dCohen = 0.002). The only non-negligible, yet still small effect was found for HOK vs. MIZ (dCohen = 0.30). The male group showed slightly different results when comparing the different FWC. Significant differences were found for HOK vs. MIZ (p < 0.001), HOK vs. PUM (p = 0.003), HOK vs. SAU (p = 0.005), and MIZ vs. SAU (p = 0.047). Effect sizes were negligible for MIZ vs. SAU (dCohen = 0.08), small for HOK vs. PUM (dCohen = 0.42) and HOK vs. SAU (dCohen = 0.42), and medium for HOK vs. MIZ (dCohen = 0.53).

As for the interaction between speed and sex, a significant difference between males and females was found at v3 (p = 0.021), exhibiting a large effect size of dCohen = 1.09. When comparing the PTA at the group level for the different speeds, both the females’ and the males’ groups showed significant differences among all three speeds (p < 0.001 for v1 vs. v2, v1 vs. v3, and v2 vs. v3), with PTA generally increasing with running speed. The effect sizes in the females were large for v1 vs. v2 (dCohen = 2.86), v1 vs. v3 (dCohen = 3.66), and v2 vs. v3 (dCohen = 4.74). The males yielded similar result with large effect sizes for v1 vs. v2 (dCohen = 2.62), v1 vs. v3 (dCohen = 2.97), and v2 vs. v3 (dCohen = 2.52).

3.2. Residual shock

For all FWC, residual shock decreased with increasing running speed from 63–71% at v1 to 46–49% at v3 (Figure 3). It was observed that a proportion of the athletes exhibited single values for RSh that exceeded one. This finding suggests that those athletes performed additional active movements of the body segments above the tibiae. Given that this was the case for all measurements of subject 22, it was deemed necessary to exclude that athlete from further analysis of RSh. As the Shapiro–Wilk test revealed that the data were not normally distributed (p = 0.001), the subsequent analysis of RSh was conducted using the using aligned rank transform and mixed ANOVA. The mixed ANOVA yielded significant results for FWC (p = 0.021, ηp2 = 0.140) and speed (p < 0.001, ηp2 = 0.704) with the effect sizes being large (Table 4). In addition, it revealed significant interactions between FWC and running speed (p = 0.005, ηp2 = 0.176). Owing to this significant interaction, the main effects for FWC and running speed were not analysed further.

Figure 3.

Boxplot chart titled \"Residual shock\" displays residual shock percentage across three conditions (v1, v2, v3) for five groups (HOK, MIZ, PUM, SAU, OWN). Each box shows interquartile ranges, medians, means, and individual data points for 21 subjects, color-coded by subject, with data indicating a general decrease in residual shock from v1 to v3 across all groups.

Distribution of residual shock across five footwear conditions at the three running speeds v1, v2, and v3. Boxplots summarise the data (median, IQR, and 1.5 × IQR whiskers), while observations for individual participants are shown as dots connected by lines to illustrate within-subject changes across footwear conditions at each running speed. Footwear conditions: HOK (Hoka Rocket X2), MIZ (Mizuno Wave Rebellion Pro), PUM (Puma Fast-R Nitro Elite), SAU (Saucony Endorphin Pro 3) and OWN (own pair of non-carbon plate running shoes).

Table 4.

Results of mixed-model three-way ANOVA on RSh after aligned rank transform.

Effect p η p 2 df F Sphericity correction
FWC 0.021 * 0.140 4 3.085 Not required
FWC*Gender 0.542 0.039 4 0.780 Not required
Speed < 0.001 * 0.704 1.307 45.228 Greenhouse-Geisser
Speed*Gender 0.472 0.033 1.307 0.639 Greenhouse-Geisser
FWC*Speed 0.005 * 0.176 3.947 4.055 Greenhouse-Geisser
FWC*Speed*Gender 0.067 0.108 3.947 2.307 Greenhouse-Geisser

*, Statistically significant (p < 0.05), ηp2, partial eta-squared, df, degrees of freedom, F, F statistic.

To analyse the interaction between FWC and speed, the five FWCs were compared at the three different speeds (Table 5). Statistically significant results were found at v1 for HOK vs. OWN (p = 0.033, r = 0.64), MIZ vs. OWN (p = 0.008, r = 0.73), and SAU vs. OWN (p = 0.041, r = 0.63). For v2, statistically significant results were found for HOK vs. PUM (p = 0.033, r = 0.64) and HOK vs. OWN (p = 0.037, r = 0.63). Finally, at v3, one statistically significant result was found for the interaction between HOK and PUM (p = 0.024, r = 0.66). All significant results showed large effect sizes.

Table 5.

Post-hoc Wilcoxon signed-rank pairwise comparison of the five FWCs at the three different speeds for RSh.

FWCi vs. FWCj v p r Effect size
HOK MIZ v 1 1.000 0.09 negligible
v2 1.000 0.29 small
v 3 0.298 0.47 medium
HOK PUM v 1 1.000 0.33 medium
v2 0.033 * 0.64 large
v 3 0.024 * 0.66 large
HOK SAU v 1 1.000 0.19 small
v2 0.087 0.57 large
v 3 0.208 0.50 large
HOK OWN v 1 0.033 * 0.64 large
v2 0.037 * 0.63 large
v 3 1.000 0.30 small
MIZ PUM v 1 1.000 0.35 medium
v2 1.000 0.25 small
v 3 1.000 0.00 negligible
MIZ SAU v 1 0.386 0.45 medium
v2 1.000 0.13 small
v 3 1.000 0.21 small
MIZ OWN v 1 0.008 * 0.73 large
v2 0.630 0.41 medium
v 3 1.000 0.13 small
PUM SAU v 1 1.000 0.12 small
v2 1.000 0.25 small
v 3 0.420 0.44 medium
PUM OWN v 1 0.273 0.48 medium
v2 1.000 0.16 small
v 3 1.000 0.26 small
SAU OWN v 1 0.041 * 0.63 large
v2 0.735 0.39 medium
v 3 1.000 0.01 negligible

*, Statistically significant (p < 0.05), r, effect size of the Wilcoxon signed-rank test. Footwear conditions: HOK, Hoka Rocket X2; MIZ, Mizuno Wave Rebellion Pro; PUM, Puma Fast-R Nitro Elite; SAU, Saucony Endorphin Pro 3; and OWN, own pair of non-carbon plate running shoes.

3.3. Triaxial tibial asymmetry

3.3.1. Mean cohort results

As the Shapiro–Wilk test revealed non-normally distributed data (p < 0.001) for LTA3D, the subsequent analysis for LTA3D was conducted using aligned rank transform and mixed ANOVA. The mixed ANOVA and the subsequent pairwise comparison showed no statistically significant results (Table 6) between the different FWC and speeds (p = 0.240). Figure 4 depicts the absolute value of LTA3D for the whole cohort across all FWC and speeds, ranging from minimal mean values of 7.21% for HOK at v2 to maximal mean values of 11.76% for SAU at v1.

Table 6.

Results of mixed-model three-way ANOVA on LTA3D after aligned rank transform.

Effect p η p 2 df F Sphericity correction
FWC 0.496 0.041 4 0.852 Not required
FWC*Gender 0.367 0.041 4 0.076 Not required
Speed 0.240 0.069 2 1.478 Not required
Speed*Gender 0.798 0.011 2 0.227 Not required
FWC*Speed 0.771 0.029 8 0.607 Not required
FWC*Speed*Gender 0.802 0.028 8 0.569 Not required

*, Statistically significant (p < 0.05), ηp2, partial eta-squared, df, degrees of freedom, F, F-statistics.

Figure 4.

Boxplot graphic comparing absolute three-dimensional lower tibial asymmetry (LTA3D) percentages across footwear types—HOK, MIZ, PUM, SAU, OWN—within three velocity groups (v1, v2, v3), with individual subject data points and lines, medians, means, and interquartile ranges shown.

Distribution of LTA3D across five footwear conditions at the three running speeds v1, v2, and v3. Boxplots summarise the data (median, IQR, and 1.5 × IQR whiskers), while observations for individual participants are shown as dots connected by lines to illustrate within-subject changes across footwear conditions at each running speed. Footwear conditions: HOK (Hoka Rocket X2), MIZ (Mizuno Wave Rebellion Pro), PUM (Puma Fast-R Nitro Elite), SAU (Saucony Endorphin Pro 3) and OWN (own pair of non-carbon plate running shoes).

3.3.2. Individual results

On the individual level, the analysis of the LTA3D reveals that the outcome differs substantially between subjects. Figures 5A–D illustrates this high inter-individual variance of FWC effects based on four exemplary athletes: Subject 15, for instance, demonstrates LTA3D at a stable level of 8.8 ± 4.3% across all FWCs and speeds. In contrast, Subject 10 exhibits a decline in LTA3D with increasing running speed from 14.6 ± 8.3% at v1 to 2.3 ± 2.2% at v3. Which is virtually independent of FWC. As depicted in the panel of Subject 9, that subject showed an increase in LTA3D with higher running speeds. In addition, there is a concomitant change of the sign of the asymmetry from one leg to the other as speed increases. In contrast to those examples, Subject 7 does not seem to follow a systematic trend but rather demonstrates varying degrees of LTA3D across the FWCs and speeds.

Figure 5.

Four grouped vertical bar charts labeled A to D show LTA₃D percentage results for subjects 15, 10, 9, and 7 across five categories: HOK, MIZ, PUM, SAU, and OWN. Each category contains three colored bars (green v₁, yellow v₂, orange v₃). Insets show σ and V values varying by subject. Subject 15 and 10 mainly exhibit negative values, subject 9 shows mixed results, and subject 7 has strongly positive results for PUM, SAU, and OWN. Axes and legends are clearly marked.

(A–D) Examples of LTA3D (triaxial lateral tibial asymmetry) of 4 out of 22 subjects at the three running speeds v1, v2 and v3 for the five footwear conditions HOK (Hoka Rocket X2), MIZ (Mizuno Wave Rebellion Pro), PUM (Puma Fast-R Nitro Elite), SAU (Saucony Endorphin Pro 3) and OWN (own pair of non-carbon plate training shoes). σ = standard deviation, V = coefficient of variation.

3.3.3. Influence of the dominant leg on Lta3d

The χ2 test to illicit any potential link between lateral asymmetry and leg dominance (Table 7) revealed no statistically significant difference (p = 0.240) between the distributions of LTA3D and P, implying that habitual leg dominance had no effect on kinematic leg asymmetry or vice versa [see Section 2.5, particularly explanation following Equation (7)].

Table 7.

Self-reported leg dominance of the participants.

Criterion Left leg dominant Right leg dominant Indifferent leg dominance
Jumping leg 11 11 0
Stance leg 22 0 0

4. Discussion

The aim of this study was to determine the effects of CPRS compared to non-CPRS on the biomechanical load metrics PTA, residual shock and lateral asymmetry index.

Our results show that PTA was increased with running speed in both sexes, an effect that is known from non-CPRS (18). However, at the highest running speed v3, statistically significant differences in PTA were observed between the sexes. This phenomenon may be attributable to the divergent running speed levels exhibited by the two gender groups, with the male subjects running approximately 15% faster than the females at v3. At this point, it may be argued that the sex-specific findings of this study should be treated cautiously because the initial power analysis had been conducted for a combined group of both sexes (n ≥ 21), whereas a sex-specific analysis of biomechanical metrics may require a higher number of runners per sex than the actual 13 men and 9 women participating in this study. However, because the type I error associated with the pertinent statistical analysis is still controlled by α < 0.05, the significant result for sex-specific differences observed in this study remains statistically valid and sound, even though the corresponding type II error may have exceeded the initially defined value β = 0.2 (favouring false-negative results instead of false-positives).

Moreover, the observed trend of an increase in PTA with increasing speed on a group level is consistent across both groups. When comparing the FWCs for each sex separately, HOK showed significant differences from the other FWCs, with HOK having higher PTA values. Contrary to the assumption that more cushioning may lead to lower PTA, it was shown in previous research that more cushioning actually results in higher PTA, at least in non-CPRS (12). This inverse relationship between the level of cushioning and PTA amplitudes is likely to be one reason why HOK produces higher PTA values in the subjects. Further research is needed to validate this hypothesis. It can be concluded that CPRS do not substantially change the amplitudes of PTA in comparison to non-CPRS. Possibly, the comparable PTA may suggest, on the individual level, that also internal tibial loads may be similar. However, this remains a debatable hypothesis in view of the fact that both intra- and inter-individual correlations between PTA and actual bone loading have been shown to be only weekly correlated (19, 20).

The residual shock exhibited a decreasing trend with increasing running speed. This indicates that, at higher speeds, there is a reduction in the acceleration of the tibia that is transmitted to the sacrum. The residual shock levels exhibited a range from about 63% to 71% at v1, and 46% to 49% at v3. This finding aligns with the results reported in the extant literature on non-CPRS (18, 45, 53), suggesting a comparable response of CPRS in this regard. However, upon examination of the absolute values for residual shock, it was found that the mean proportion of residual shock that is measurable at the sacrum of ≈57% is larger than in previous studies, where ≈32% and ≈48% were reported (18, 44). This is most probably attributable to the difference in athletic populations participating in this study: In contrast to previous studies (18, 44, 45), this study recruited amateur runners of both sexes instead of elite runners or male runners only. Another potential explanation for the higher values of residual shock observed in this study could be attributed to the softer nature of the treadmill used in this investigation, as compared to the more rigid treadmills employed in previous studies (18, 44, 45). At fixed running speeds significant differences in residual shock were observed between some of the FWCs. The residual shock appeared to be lower for CPRS than for OWN in a few cases, namely at v1 for HOK (≈66%), MIZ (≈63%) and SAU (≈67%) as compared to OWN (≈71%), and at v2 for HOK (≈53%) as compared to OWN (≈58%). However, the substantial structural heterogeneity in the OWN condition (see below) may have contributed to this statistical outcome. Moreover, HOK showed statistically significantly lower RSh values than PUM at v2 (≈53% for HOK, and ≈56% for PUM) and v3 (≈46% for HOK, and ≈49% for PUM). As HOK frequently differed from other footwear models in our study, the observed effects may partly be attributed to the specific cushioning properties of the HOK shoe, which has been reported to be more compliant than other CPRS shoes. This increased cushioning has been shown to result in higher PTA and consequently reduced residual shock (12). This may likewise be applicable in the context of the observation that non-CPRS show elevated levels of residual shocks, as the cushioning appears to be lower in comparison with that of CPRS. Therefore, future research should explicitly investigate the influence of different foams on residual shock in CPRS.

As to the third key result of this study, the asymmetry index, CPRS did not affect the degree of lateral asymmetry in PTA during running. Median asymmetry indices ranged from 7.5 to 11.8% across all speeds, with these values being described as physiological in previous studies (21, 33). Hence, higher cushioning and energy recoil observed in the CPRS of this study did not appear to increase existing asymmetries, a finding that is consistent with the notion that these asymmetries manifest to a comparable extent in both legs. Therefore, it can be concluded that the extent to which asymmetries occur in runners is attributable to an intrinsic individual factor (23). Furthermore, no statistical association between the dominant leg and the side of lateral asymmetry was observed, meaning that the side of the dominant leg (i.e., left or right) was not linked to the side of lateral asymmetry. This result is in line with a recent finding that the dominant leg in terms of PTA or ground reaction forces, respectively, is not associated with the side of a specific overuse injuries in runners (24).

An analysis of the individual results reveals a variety of peculiarities of runners, each responding differently to CPRS. Some of the runners demonstrated a decline in triaxial tibial asymmetry with increasing running speeds. This finding is consistent with the observation in elite athletes reported previously (23). It is argued that such elite runners improve their efficiency in running at higher speeds and exhibit an optimised locomotion pattern. By contrast, the present study also revealed that some runners demonstrate an increasing degree of asymmetry as their running speed increases. This effect may be due to a lower training level of several of the runners participating in this study. It is reasonable to hypothesise that some less trained amateur runners may experience a loss of stability with increasing degree of exhaustion, which is likely to result in a deviation from their optimally balanced running gait. Furthermore, some of the runners in this study demonstrated a relatively consistent degree of LTA3D across all FWCs and running speeds. This finding may indicate that neither exhaustion nor enhancement in running technique exert an influence on their individual asymmetry. Finally, other runners exhibited no clear pattern, but rather different reactions to each FWC, resulting in varying degrees of LTA3D in each FWC.

Altogether, the different responses of the athletes to CPRS show that CPRS may either substantially alter the individual degree of lateral asymmetry in running gait compared to their preferred non-CPRS, both in terms of increase (see, e.g., athletes 11, 20 for MIZ in Figure S1) or decrease (see, e.g., athletes 7, 13 for HOK in Figure S1), or may leave it as is (see athletes 12, 15 for SAU in Figure S1). Therefore, we recommend to first individually test if a specific CPRS substantially changes LTA3D, before using it in training or competition. By virtue of a variety of suitable and affordable IMUs available on the market today, this does not seem to be an unrealistic option any longer.

Some limitations of this study must be noted. First, due to restrictions in budget and time, this study could only test 4 different CPRS, and only one test day per athlete could be performed with the CPRS. Second, the effect of fatigue could not be accounted for as each FWC was tested in a random order, without a randomisation of the speeds. The randomisation of the order in which the shoes were tested was deemed to be the most appropriate approach in order to avoid any potential bias between the FWC tested. Furthermore, because of the randomisation of the shoes, each FWC was used in each position (1–5), resulting in statistically similar fatigue effects for each FWC. To investigate the influence of fatigue on, e.g., the asymmetry index when wearing CPRS in future studies, incorporating longer intervals and a larger number of test days seem advisable. Moreover, no stand-alone testing of the pure mechanical properties of the shoes could be conducted (e. g., measuring midsole hardness, differences in carbon plate geometry etc.) because our laboratory does not allow for such procedures. Finally, it is also important to note that the shoe condition OWN was individual for each athlete, thereby representing a variety of different footwear metrics such as stack height, stiffness and drop. In particular, the mass of individual shoes in the OWN condition differed by a maximum of 147 g (range 188–335 g; the latter figure representing an outlier), whereas the mass of individual shoes in the four CPRS conditions differed by only 45 g (range 186–231 g), representing only a third of the difference observed in OWN. Therefore, this substantial structural heterogeneity in OWN may have obscured any genuine differences between CPRS and simple footwear. This limits the comparison of the CPRS FWCs as a whole to OWN, but is required to enable a comparison of the individual asymmetry index among different FWCs, as only the individual own FWC can safely be considered a valid reference for individual asymmetry in PTA. To this end, Supplementary Figure 1 compares the LTA3D asymmetry metric at the individual level for all subjects separately.

5. Conclusion

This study provides insight into the alterations in biomechanical parameters (PTA, residual shock and lateral asymmetry index) that individuals can expect when wearing CPRS. At cohort level, PTA differed between footwear models and increased with running speed. In contrast, residual shock showed limited footwear-related differences and generally decreased with increasing speed. No group-level effects of FWC or speed were observed for the lateral asymmetry index. However, as the non-carbon plate condition OWN was highly heterogeneous by design, the comparability between CPRS and simple footwear technology may be limited. Notwithstanding, sex-specific differences and inter-individual variability were evident across the measured parameters. These findings highlight that responses to CPRS are highly individual. From a practical perspective, athletes and practitioners may therefore benefit from evaluating different CPRS models on an individual basis when aiming to identify the most suitable footwear for a given runner and use case.

Acknowledgments

We would like to thank all the participants in this study for their time and effort. We would also like to thank Eric Quellmalz for providing us with test shoes from four manufacturers free of charge for the duration of this study.

Funding Statement

The author(s) declared that financial support was not received for this work and/or its publication.

Footnotes

Edited by: Pietro Picerno, University of Sassari, Italy

Reviewed by: Zihan Yang, Beijing Institute of Fashion Technology, China

Edgars Bernāns, Riga Stradins University, Sports Healthcare Research Center, Latvia

Abbreviations AFT, advanced footwear technology; CPRS, carbon plate running shoe; FWC, footwear condition; HOK, Hoka Rocket X2; IMU, inertial measurement unit; LTA3D, triaxial lateral tibial asymmetry; MIZ, Mizuno Wave Rebellion Pro; OWN, individual own pair of training shoes; PSA, peak sacral acceleration; PTA, peak tibial acceleration; PUM, Puma Fast-R Nitro Elite; RSh, residual shock; SAU, Saucony Endorphin Pro 3; SD, standard deviation; VT1 & VT2, ventilatory thresholds 1 & 2.

Data availability statement

The raw data supporting the conclusions of this article will be made available by the authors, without undue reservation.

Ethics statement

The studies involving humans were approved by Ethics Committee of the Department of Engineering and Industrial Design at the Magdeburg-Stendal University of Applied Sciences. The studies were conducted in accordance with the local legislation and institutional requirements. The participants provided their written informed consent to participate in this study.

Author contributions

MR: Formal analysis, Funding acquisition, Investigation, Methodology, Resources, Validation, Data curation, Visualization, Writing – original draft. RS: Writing – review & editing. OU: Writing – review & editing, Conceptualization, Formal analysis, Funding acquisition, Investigation, Methodology, Project administration, Resources, Software, Supervision, Validation.

Conflict of interest

The author(s) declared that this work was conducted in the absence of any commercial or financial relationships that could be construed as a potential conflict of interest.

Generative AI statement

The author(s) declared that generative AI was not used in the creation of this manuscript.

Any alternative text (alt text) provided alongside figures in this article has been generated by Frontiers with the support of artificial intelligence and reasonable efforts have been made to ensure accuracy, including review by the authors wherever possible. If you identify any issues, please contact us.

Publisher's note

All claims expressed in this article are solely those of the authors and do not necessarily represent those of their affiliated organizations, or those of the publisher, the editors and the reviewers. Any product that may be evaluated in this article, or claim that may be made by its manufacturer, is not guaranteed or endorsed by the publisher.

Supplementary material

The Supplementary Material for this article can be found online at: https://www.frontiersin.org/articles/10.3389/fspor.2026.1908480/full#supplementary-material

Datasheet1.docx (888.7KB, docx)

References

  • 1.Frederick E. Let’s Just Call it Advanced Footwear Technology (AFT). Taylor & Francis; (2022). p. 131–131. [Google Scholar]
  • 2.Hébert-Losier K, et al. , Evidence of variable performance responses to the Nike 4% shoe: Definitely not a game-changer for all recreational runners. (2020).
  • 3.Jacko T, Bartsch J, Von Diecken C, Ueberschär O. Validity of current smartwatches for triathlon training: how accurate are heart rate, distance, and swimming readings? Sensors. (2024) 24(14):4675. 10.3390/s24144675 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 4.Burns GT, Joubert DP. Running shoes of the postmodern footwear era: a narrative overview of advanced footwear technology. Int J Sports Physiol Perform. (2024) 19(10):975–986. 10.1123/ijspp.2023-0446 [DOI] [PubMed] [Google Scholar]
  • 5.Hoogkamer W, Kipp S, Frank JH, Farina EM, Luo G, Kram R. A comparison of the energetic cost of running in marathon racing shoes. Sports Med. (2018) 48(4):1009–1019. 10.1007/s40279-017-0811-2 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 6.Hunter I, McLeod A, Valentine D, Low T, Ward J, Hager R. Running economy, mechanics, and marathon racing shoes. J Sports Sci. (2019) 37(20):2367–2373. 10.1080/02640414.2019.1633837 [DOI] [PubMed] [Google Scholar]
  • 7.Riedl M, Von Diecken C, Ueberschär O. One shoe to fit them all? Effect of Various carbon plate running shoes on running economy in male and female amateur triathletes and runners at individual training and race paces. Appl Sci. (2024) 14(24):11535. 10.3390/app142411535 [DOI] [Google Scholar]
  • 8.Bruvere DD, Bernans E. Mechanisms, economy, and performance of advanced footwear technology in endurance running—a review. Muscles. (2026) 5(1):2. 10.3390/muscles5010002 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 9.Reynolds SR, Hastert LM, Nodland NM, Matthews IR, Wilkins BW, Gidley AD. The effect of carbon fiber plated shoes on submaximal running mechanics in non-elite runners. Footwear Sci. (2023) 15(3):171–177. 10.1080/19424280.2023.2218316 [DOI] [Google Scholar]
  • 10.Kakouris N, Yener N, Fong DTP. A systematic review of running-related musculoskeletal injuries in runners. J Sport Health Sci. (2021) 10(5):513–522. 10.1016/j.jshs.2021.04.001 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 11.Tenforde AS, Kraus E, Fredericson M. Bone stress injuries in runners. Phys Med Rehabil Clin. (2016) 27(1):139–149. 10.1016/j.pmr.2015.08.008 [DOI] [PubMed] [Google Scholar]
  • 12.Kulmala J-P, Kosonen J, Nurminen J, Avela J. Running in highly cushioned shoes increases leg stiffness and amplifies impact loading. Sci Rep. (2018) 8:8. 10.1038/s41598-018-35980-6 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 13.Xiang L, Gu Y, Rong M, Gao Z, Yang T, Wang A, Shim V, Fernandez J, Shock acceleration and attenuation during running with minimalist and maximalist shoes: a time- and frequency-domain analysis of tibial acceleration. Bioengineering. (2022) 9(7):322. 10.3390/bioengineering9070322 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 14.Derie R, Robberechts P, Van den Berghe P, Gerlo J, De Clercq D, Segers V, Davis J, Tibial acceleration-based prediction of maximal vertical loading rate during overground running: a machine learning approach. Front Bioeng Biotechnol. (2020) 8:33. 10.3389/fbioe.2020.00033 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 15.Sheerin K, et al. The reliability and variability of three-dimensional tibial acceleration during running. in 34th International Conference of Biomechanics in Sport, Tsukuba, Japan (2016). [Google Scholar]
  • 16.Sheerin KR, Besier TF, Reid D, Hume PA. The one-week and six-month reliability and variability of three-dimensional tibial acceleration in runners. Sports Biomech. (2018) 17(4):531–540. 10.1080/14763141.2017.1371214 [DOI] [PubMed] [Google Scholar]
  • 17.Sheerin KR, Reid D, Besier TF. The measurement of tibial acceleration in runners—a review of the factors that can affect tibial acceleration during running and evidence-based guidelines for its use. Gait Posture. (2019) 67:12–24. 10.1016/j.gaitpost.2018.09.017 [DOI] [PubMed] [Google Scholar]
  • 18.Ueberschär O, Fleckenstein D, Warschun F, Kränzler S, Walter N, Hoppe MW. Measuring biomechanical loads and asymmetries in junior elite long-distance runners through triaxial inertial sensors. Sports Orthop Traumatol. (2019) 35(3):296–308. 10.1016/j.orthtr.2019.06.001 [DOI] [Google Scholar]
  • 19.Matijevich ES, Scott LR, Volgyesi P, Derry KH, Zelik KE. Combining wearable sensor signals, machine learning and biomechanics to estimate tibial bone force and damage during running. Hum Mov Sci. (2020) 74:102690. 10.1016/j.humov.2020.102690 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 20.Zandbergen MA, Ter Wengel XJ, Van Middelaar RP, Buurke JH, Veltink PH, Reenalda J. Peak tibial acceleration should not be used as indicator of tibial bone loading during running. Sports Biomech. (2023) 24:1–18. 10.1080/14763141.2022.2164345 [DOI] [PubMed] [Google Scholar]
  • 21.Carpes FP, Mota CB, Faria IE. On the bilateral asymmetry during running and cycling - a review considering leg preference. Phys Ther Sport. (2010) 11(4):136–42. 10.1016/j.ptsp.2010.06.005 [DOI] [PubMed] [Google Scholar]
  • 22.Cavanagh PR, Lafortune MA. Ground reaction forces in distance running. J Biomech. (1980) 13(5):397–406. 10.1016/0021-9290(80)90033-0 [DOI] [PubMed] [Google Scholar]
  • 23.Ueberschär O, Fleckenstein D, Warschun F, Walter N, Hoppe MW. Case report on lateral asymmetries in two junior elite long-distance runners during a high-altitude training camp. Sports Orthop Traumatol. (2019) 35(3):399–406. 10.1016/j.orthtr.2019.06.002 [DOI] [Google Scholar]
  • 24.Riedl M, Roediger J, Pohlmann J, Hesse J, Warschun F, Wolfarth B, Ueberschär O, Laterality of sacral stress fractures in trained endurance athletes: are there biomechanical or orthopaedic risk factors? Sports Orthop Traumatol. (2022) 38(1):36–46. 10.1016/j.orthtr.2021.11.011 [DOI] [Google Scholar]
  • 25.Mizrahi J, Verbitsky O, Isakov E, Daily D. Effect of fatigue on leg kinematics and impact acceleration in long distance running. Hum Mov Sci. (2000) 19(2):139–151. 10.1016/S0167-9457(00)00013-0 [DOI] [Google Scholar]
  • 26.Milner C, Ferber R, Pollard C, Hamill J, Davis I. Biomechanical factors associated with tibial stress fracture in female runners. Med Sci Sports Exerc. (2006) 38(2):323–8. 10.1249/01.mss.0000183477.75808.92 [DOI] [PubMed] [Google Scholar]
  • 27.Millum J, Wendler D, Emanuel EJ. The 50th anniversary of the declaration of Helsinki: progress but many remaining challenges. Jama. (2013) 310(20):2143–2144. 10.1001/jama.2013.281632 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 28.Hoka. Rocket X 2. Available online at: https://www.hoka.com/de/de/race/rocket-x-2/1127927.html (cited 2024 12-02).
  • 29.Schepe S. Mizuno Wave Rebellion PRO: Neue Ära der Carbonschuhe. Available online at: https://triathlon.de/blogs/journal/mizuno-wave-rebellion-pro-neue-aera-der-carbonschuhe (cited 2024 12-02).
  • 30.Runnea. Mizuno Wave Rebellion Pro. (2023) Available online at: https://www.runnea.de/laufschuhe/mizuno/wave-rebellion-pro/1018428/ (cited 2025 03-29).
  • 31.Scharff N. Testbericht: Puma FAST-R Nitro Elite - Erfrischend anders! (German). (2022) Available online at: https://www.roadtrailrun.com/2022/04/testbericht-puma-fast-r-nitro-elite.html (cited 2024 12-02).
  • 32.Lindemann H. Saucony Endorphin Pro 3 im Test. (2022) Available online at: https://www.runnersworld.de/laufschuhe/saucony-endorphin-pro/ (cited 2024 12-02).
  • 33.Ueberschär O, Fleckenstein D, Warschun F, Walter N, Wüstenfeld JC, Wolfarth B, Hoppe MW, Energy cost of running under hypogravity in well-trained runners and triathletes: a biomechanical perspective. Int J Comput Sci Sport. (2019) 18(2):60–80. 10.2478/ijcss-2019-0014 [DOI] [Google Scholar]
  • 34.Fercher C, Bartsch J, Kluge S, Schneider F, Liedtke AM, Schleichardt A, Ueberschär O, Applying multi-purpose commercial inertial sensors for monitoring equine locomotion in equestrian training. Sensors. (2024) 24(24):8170. 10.3390/s24248170 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 35.Wesely S, et al. , Artificial intelligence for objective assessment of acrobatic movements: How to apply machine learning for identifying tumbling elements in cheer sports. arXiv preprint arXiv:2503.04764 (2025).
  • 36.Benson LC, Räisänen AM, Clermont CA, Ferber R. Is this the real life, or is this just laboratory? A scoping review of IMU-based running gait analysis. Sensors. (2022) 22(5):1722. 10.3390/s22051722 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 37.Zeng Z, Liu Y, Hu X, Tang M, Wang L. Validity and reliability of inertial measurement units on lower extremity kinematics during running: a systematic review and meta-analysis. Sports Med Open. (2022) 8(1):86. 10.1186/s40798-022-00477-0 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 38.Paulich M, et al. Xsens MTw Awinda: Miniature Wireless Inertial-Magnetic Motion Tracker for Highly Accurate 3D Kinematic Applications. Enschede, the Netherlands: Xsens Technologies B.V. (2018). p. 1–9. [Google Scholar]
  • 39.Ueberschär O, Fleckenstein D, Wüstenfeld JC, Warschun F, Falz R, Wolfarth B. Running on the hypogravity treadmill AlterG® does not reduce the magnitude of peak tibial impact accelerations. Sports Orthop Traumatol. (2019) 35(4):423–434. 10.1016/j.orthtr.2019.10.001 [DOI] [Google Scholar]
  • 40.Jones AM, Doust JH. A 1% treadmill grade most accurately reflects the energetic cost of outdoor running. J Sports Sci. (1996) 14(4):321–327. 10.1080/02640419608727717 [DOI] [PubMed] [Google Scholar]
  • 41.Sitko S, Artetxe X, Bonnevie-Svendsen M, Galán-Rioja MÁ, Gallo G, Grappe F, Leo P, Mateo M, Mujika I, Sanders D, Seiler S, Zabala M, Valenzuela PL, Viribay A, What is “zone 2 training”?: experts’ viewpoint on definition, training methods, and expected adaptations. Int J Sports Physiol Perform. (2025) 1(aop):1–4. 10.1123/ijspp.2024-0303 [DOI] [PubMed] [Google Scholar]
  • 42.NI LabVIEW development team. Peak Detector VI. (2026). Available online at: https://www.ni.com/docs/en-US/bundle/labview-api-ref/page/vi-lib/analysis/8numeric-llb/peak-detector-vi.html (cited 2026 2026-07-26).
  • 43.Ueberschär O, Fleckenstein D, Warschun F, Walter N, Wüstenfeld JC, Wolfarth B, Hoppe MW, Erratum to: energy cost of running under hypogravity in well-trained runners and triathletes: a biomechanical perspective – international journal of computer science in sport 18(2), pages 60–80 (2019). Int J Comput Sci Sport. (2024) 23(2):48–50. 10.2478/ijcss-2024-0011 [DOI] [Google Scholar]
  • 44.Reenalda J, Maartens E, Buurke JH, Gruber AH. Kinematics and shock attenuation during a prolonged run on the athletic track as measured with inertial magnetic measurement units. Gait Posture. (2019) 68:155–160. 10.1016/j.gaitpost.2018.11.020 [DOI] [PubMed] [Google Scholar]
  • 45.Mercer J, Vance J, Hreljac A, Hamill J. Relationship between shock attenuation and stride length during running at different velocities. Eur J Appl Physiol. (2002) 87(4-5):403–8. 10.1007/s00421-002-0646-9 [DOI] [PubMed] [Google Scholar]
  • 46.Delgado T, Kubera-Shelton E, Robb R, Hickman R, Wallmann H, Dufek J. Effects of foot strike on low back posture, shock attenuation, and comfort. J Orthop Sports Phys Ther. (2013) 43(1):A130–A131. 10.1249/MSS.0b013e3182781b2c [DOI] [PubMed] [Google Scholar]
  • 47.Voloshin AS, Mizrahi J, Verbitsky O, Isakov E. Dynamic loading on the human musculoskeletal system —effect of fatigue. Clin Biomech. (1998) 13(7):515–520. 10.1016/S0268-0033(98)00030-8 [DOI] [PubMed] [Google Scholar]
  • 48.Cohen J. Eta-Squared and partial eta-squared in fixed factor anova designs. Educ Psychol Meas. (1973) 33(1):107–112. 10.1177/001316447303300111 [DOI] [Google Scholar]
  • 49.Richardson JT. Eta squared and partial eta squared as measures of effect size in educational research. Educ Res Rev. (2011) 6(2):135–147. 10.1016/j.edurev.2010.12.001 [DOI] [Google Scholar]
  • 50.Cohen J. A power primer. Psychol Bull. (1992) 112(1):155–9. 10.1037/0033-2909.112.1.155 [DOI] [PubMed] [Google Scholar]
  • 51.Cohen J. Statistical Power Analysis for the Behavioral Sciences. Vol. 2nd. Hillsdale, NJ, USA: Lawrence Erlbaum Associates; (1988). [Google Scholar]
  • 52.Wobbrock JO, et al. The aligned rank transform for nonparametric factorial analyses using only anova procedures. in Proceedings of the SIGCHI Conference on Human Factors in Computing Systems (2011). [Google Scholar]
  • 53.Hamill J, Derrick TR, Holt KG. Shock attenuation and stride frequency during running. Hum Mov Sci. (1995) 14(1):45–60. 10.1016/0167-9457(95)00004-C [DOI] [Google Scholar]

Associated Data

This section collects any data citations, data availability statements, or supplementary materials included in this article.

Supplementary Materials

Datasheet1.docx (888.7KB, docx)

Data Availability Statement

The raw data supporting the conclusions of this article will be made available by the authors, without undue reservation.


Articles from Frontiers in Sports and Active Living are provided here courtesy of Frontiers Media SA

RESOURCES